enhanced flame test

GAALFLEX® CONTROL H07ZZ-F: Comprehensive Halogen-Free Fire-Safe Power Cable with Complete Single-Core and Multi-Core Standardization (1.5–500 mm² Single / 2–36 Core Multi) for Building Electrical Infrastructure (450/750V Nominal Voltage, 2.5 kV Test Voltage per DIN VDE 0281, Zero-Halogenated-Acid-Gas Release per IEC 60754-1 (

GAALFLEX® CONTROL H07ZZ-F

GAALFLEX® CONTROL H07ZZ-F: Comprehensive Halogen-Free Fire-Safe Power Cable with Complete Single-Core and Multi-Core Standardization (1.5–500 mm² Single / 2–36 Core Multi) for Building Electrical Infrastructure (450/750V Nominal Voltage, 2.5 kV Test Voltage per DIN VDE 0281, Zero-Halogenated-Acid-Gas Release per IEC 60754-1 (
GAALFLEX® CONTROL 1000 CH: Fire-Safe Halogen-Free Multi-Core Shielded Control Cable with Triple-Layer Zero-Halogen Architecture (Halogen-Free Type TI6 Insulation + Tinned-Copper-Braid Overall Screen + Halogen-Free Type TM7 Outer Sheath) for Medical Facilities, Data Centers, and Fire-Code-Compliant Installations (0.6/1 kV Nominal Voltage, 4 kV Test Voltage per DIN VDE 0281, Class 5 Flexible Red Bare Copper per IEC 60228, Triple-Layer Zero-Halogen Architecture Combining Halogen-Free Type TI6 Insulation Protecting Conductor Bundles, Tinned-Copper-Braid Overall Screen Achieving ≥75 dB EMI Attenuation, Halogen-Free Type TM7 Outer Sheath Providing Environmental Protection Without Acid-Gas Release During Fire Conditions, IEC 60332-3-24 Enhanced Flame Test Certification Exceeding Standard IEC 60332-1-2 Baseline and Achieving European Building Code Fire-Safety Requirements, Zero-Halogenated-Acid-Gas Release per IEC 60754-1 (

GAALFLEX® CONTROL 1000 CH

GAALFLEX® CONTROL 1000 CH: Fire-Safe Halogen-Free Multi-Core Shielded Control Cable with Triple-Layer Zero-Halogen Architecture (Halogen-Free Type TI6 Insulation + Tinned-Copper-Braid Overall Screen + Halogen-Free Type TM7 Outer Sheath) for Medical Facilities, Data Centers, and Fire-Code-Compliant Installations (0.6/1 kV Nominal Voltage, 4 kV Test Voltage per DIN VDE 0281, Class 5 Flexible Red Bare Copper per IEC 60228, Triple-Layer Zero-Halogen Architecture Combining Halogen-Free Type TI6 Insulation Protecting Conductor Bundles, Tinned-Copper-Braid Overall Screen Achieving ≥75 dB EMI Attenuation, Halogen-Free Type TM7 Outer Sheath Providing Environmental Protection Without Acid-Gas Release During Fire Conditions, IEC 60332-3-24 Enhanced Flame Test Certification Exceeding Standard IEC 60332-1-2 Baseline and Achieving European Building Code Fire-Safety Requirements, Zero-Halogenated-Acid-Gas Release per IEC 60754-1 (