What Are UNE 22560 and UNE 22561? Scope, Definitions, and Core Purpose
The UNE 22560 and UNE 22561 standards represent the final and often most underestimated element of the Spanish and Latin American underground mining cable ecosystem. Where UNE 22511 and UNE 22512 govern the power distribution cables that energize mining equipment, the 22560 and 22561 standards govern the signal, control, and interlock cables that command and protect that equipment. These are the “nervous system” cables of a mine — the communication network that tells a continuous miner when to advance and when to halt, that triggers emergency stops, that monitors hoisting rope tension on shaft equipment, that controls conveyor sequencing, and that enables the protective interlocking that prevents a piece of equipment from operating unless all safety preconditions are met.
UNE 22560 formally defines flexible multi-core cables for underground mining with voltage ratings up to 500 V or 0.6/1 kV, with no metallic armour protection — designed for installation within equipment enclosures, along protected cable trays in main gate roads, or in areas where mechanical damage risk is minimal. UNE 22561 is its armoured sister standard, incorporating steel wire braid or steel tape protection, specified for installation in rough terrain areas where mechanical damage from rock fall, equipment collision, or floor contact is a credible risk. Both standards mandate that the cable be designed as a multi-core concentric stranded bundle — not the parallel-laid three or four conductors common in power cables, but rather seven, twelve, nineteen, or more individually insulated cores twisted concentrically around a central axis, allowing compact packaging of numerous independent control circuits within a single cable jacket.
The distinction between these standards is not merely mechanical armour presence or absence. Control cables are tested against an entirely different set of safety criteria than power cables because their failure mode is fundamentally different. A power cable failure results in loss of energy to equipment — dangerous but localized. A control cable failure can disable the interlock system that prevents a continuous miner from advancing into unsafe ground, or can disable the emergency stop circuit that should halt a conveyor if a worker falls into it. A control cable fire, burning in a tightly bundled cable tray with other control cables, must not spread flame between cables because control cables are typically routed in shared ducts and cable carriers where one cable’s ignition could cascade to adjacent circuits. Therefore, control cables are tested for bundle flame propagation (EN 60332-3) rather than single-cable flame propagation tests — a more stringent requirement that demands careful attention to outer sheath formulation and cable spacing in bundle installation.


![GAALFLEX® VFD 2XSLCHK-J 3 GAALFLEX® VFD 2XSLCHK-J: CPR-Compliant Oil-Resistant Halogen-Free Variable Frequency Drive Inverter Connection Cable for European Building and Industrial Applications with Oil-Exposure Environments, Higher-Temperature Industrial Systems, and Mining Operations (0.6/1 kV Nominal Voltage, 4 kV Test Voltage, CPR EU 305/2011 + EN 50575:2014+A1:2016 Compliance with Dca-S1b,d2,a1 Fire Classification [Enhanced Performance: Low Smoke, Zero Halogen, Minimal Toxicity, Limited Corrosive Gases], Comprehensive Dual-Configuration Portfolio [4-Core and 3+3 Earth Conductor Versions Plus New 7-Core Option], 1.5–300 mm² Conductor Range Enabling Complete VFD Specification Across Industrial Applications, Flexible Class 5 Red Copper per IEC 60228, Special XLPE [Cross-Linked Polyethylene] Halogen-Free Insulation with Oil Resistance per IEC 60811-404, Low Corrosive Gas Emission per IEC 60754-2, Low Smoke Density per IEC 61034-1-2, Aluminum Tape + PETP Foil + Tinned Copper Braid Triple-Layer Shielding, Low Mutual Capacitance [70–410 nF/km] Minimizing Cross-Talk, Low Coupling Resistance [Max 250 Ω/km] Supporting Low-Impedance Control, Black Halogen-Free PVC Outer Sheath with UV Resistance for Outdoor Industrial Deployment, Temperature Range −40 to +90°C [Fixed Laying] or −15 to +90°C [Flexible Application] with +90°C Conductor and +250°C Short-Circuit Capability Enabling High-Temperature Industrial Facilities, Mining Application Suitability per DIN VDE 0250, Electromagnetic Compatibility per EN 55011 / DIN VDE 0875 / EN 61800-3, Self-Extinguishing and Flame-Retardant per DIN VDE 0482-265-2-1 / EN 50265-2-1 / IEC 60332-1-2 / DIN VDE 0482 part 266-4-2 / EN 50266-4-2 / IEC 60332-3-24, Insulation Resistance 200+ MΩ·km, Radiation Resistance to 80×10⁶ cJ/kg, Oil-Resistant Construction Eliminating Cable Degradation in Petrochemical/Automotive/Food Processing Environments, Halogen-Free Zero-Halogen Construction Eliminating Toxic Chlorine/Fluorine Emissions During Fire, RoHS and CE Approved, and Complete European and International Compliance Enabling Building Code Acceptance and Professional VFD System Integration in High-Temperature Oil-Exposure Environments)](https://feichuncables.com/blog/wp-content/uploads/image-1387.avif)
![GAALFLEX® VFD 2XSLCYK 4 GAALFLEX® VFD 2XSLCYK: CPR-Compliant Halogen-Free Variable Frequency Drive Inverter Connection Cable for European Building Applications, Industrial Frequency Converter Systems, and Mining Operations (0.6/1 kV Nominal Voltage, 4 kV Test Voltage, CPR EU 305/2011 + EN 50575:2014+A1:2016 Compliance with Cca-s3,d1,a3 Fire Classification [Low Smoke, Zero Halogen, Minimal Toxicity], Comprehensive Dual-Configuration Portfolio [4-Core and 3+3 Earth Conductor Versions], 1.5–300 mm² Conductor Range Enabling Complete VFD Specification Across Industrial Applications, Flexible Class 5 Red Copper per IEC 60228, Special XLPE [Cross-Linked Polyethylene] Insulation Providing Halogen-Free Performance, Low Corrosive Gas Emission, and Superior Thermal Stability, Aluminum Tape + PETP Foil + Tinned Copper Braid Triple-Layer Shielding, Low Mutual Capacitance [70–410 nF/km] Minimizing Cross-Talk, Low Coupling Resistance [Max 250 Ω/km] Supporting Low-Impedance Control, Black RAL 9005 PVC Outer Sheath with UV Resistance for Outdoor Industrial Deployment, Temperature Range −40 to +70°C [Fixed Laying] or −15 to +70°C [Flexible Application] with +90°C Conductor and +250°C Short-Circuit Capability, Mining Application Suitability per DIN VDE 0250, Electromagnetic Compatibility per EN 55011 / DIN VDE 0875 / EN 61800-3, Self-Extinguishing and Flame-Retardant per DIN VDE 0482-265-2-1 / EN 50265-2-1 / IEC 60332-1-2 / EN 50399, Insulation Resistance 200+ MΩ·km, Radiation Resistance to 80×10⁶ cJ/kg, Halogen-Free Zero-Halogen Construction Eliminating Toxic Chlorine/Fluorine Emissions During Fire, Suitable for Buildings, Plants, Fixed Installations, Medium Mechanical Stress, Forced-Movement Flexible Installations in Dry/Moist/Wet Environments, Automotive and Food Industry Applications, SIMOVERT Frequency Converter Integration, Industrial Pump/Ventilator/Conveyor/Air-Conditioning Systems, RoHS and CE Approved, and Complete European and International Compliance Enabling Building Code Acceptance and Professional VFD System Integration)](https://feichuncables.com/blog/wp-content/uploads/image-1386.avif)