PE special insulation

GAALFLEX® VFD 1000 (2YSLCYK-J UL): UL-Certified Variable Frequency Drive Inverter Connection Cable for North American Industrial Motor Power Supply, Frequency Converter Integration, and Utility Distribution Applications (1000 V Nominal Voltage [UL Rating], AWM Style 2570 1000 V 80°C VW-1 Certification and AWM II A/B 1000 V 80° FT-1 Rating, 4 kV Test Voltage, Comprehensive Dual-Configuration Portfolio [4-Core and 3+3 Earth Conductor Versions], 1.5–300 mm² Conductor Range Enabling Complete North American VFD Specification from Fractional-Horsepower Servo Drives Through Maximum Industrial 3-Phase Motor Systems, Flexible Class 5 Red Copper per IEC 60228, PE Special Insulation Compound Providing Electrical Stability Across Frequency Conversion Environments, Aluminum Tape + PETP Foil + Tinned Copper Braid Triple-Layer Shielding Providing Effective EMI Suppression and Signal Integrity Critical for Frequency Converter Control, Low Mutual Capacitance [70–410 nF/km Depending on Configuration] Minimizing Cross-Talk Between Adjacent Conductors in Bundled VFD Installations, Low Coupling Resistance [Max 250 Ω/km] Supporting Low-Impedance Control Circuits, Black RAL 9005 PVC Outer Sheath with UV Resistance Enabling Outdoor and Industrial Installation Without Degradation, Temperature Range −40 to +70°C [Fixed Laying] or −5 to +70°C [Flexible Application] Standard, +80°C Rated Temperature per UL Specification for Both Fixed and Flexible Installation Enabling Higher-Ambient Industrial Facilities, +90°C Conductor and +250°C Short-Circuit Capability Supporting Transient Overvoltage Conditions During Frequency Conversion Switching, UV-Resistant Outdoor Use per DIN VDE 0250, Electromagnetic Compatibility per EN 55011 / DIN VDE 0875 / EN 61800-3, Self-Extinguishing and Flame-Retardant per DIN VDE 0482-265-2-1, Insulation Resistance 200+ MΩ·km, Radiation Resistance to 80×10⁶ cJ/kg, Flexible Bending Radius Supporting Tight Drive Enclosure Routing, RoHS and CE Approved, and Complete North American VFD Infrastructure Compliance Enabling OEM Motor Drive Integration and Process Automation Acceptance with UL Market Validation)

GAALFLEX® VFD 1000 (2YSLCYK-J UL)

GAALFLEX® VFD 1000 (2YSLCYK-J UL): UL-Certified Variable Frequency Drive Inverter Connection Cable for North American Industrial Motor Power Supply, Frequency Converter Integration, and Utility Distribution Applications (1000 V Nominal Voltage [UL Rating], AWM Style 2570 1000 V 80°C VW-1 Certification and AWM II A/B 1000 V 80° FT-1 Rating, 4 kV Test Voltage, Comprehensive Dual-Configuration Portfolio [4-Core and 3+3 Earth Conductor Versions], 1.5–300 mm² Conductor Range Enabling Complete North American VFD Specification from Fractional-Horsepower Servo Drives Through Maximum Industrial 3-Phase Motor Systems, Flexible Class 5 Red Copper per IEC 60228, PE Special Insulation Compound Providing Electrical Stability Across Frequency Conversion Environments, Aluminum Tape + PETP Foil + Tinned Copper Braid Triple-Layer Shielding Providing Effective EMI Suppression and Signal Integrity Critical for Frequency Converter Control, Low Mutual Capacitance [70–410 nF/km Depending on Configuration] Minimizing Cross-Talk Between Adjacent Conductors in Bundled VFD Installations, Low Coupling Resistance [Max 250 Ω/km] Supporting Low-Impedance Control Circuits, Black RAL 9005 PVC Outer Sheath with UV Resistance Enabling Outdoor and Industrial Installation Without Degradation, Temperature Range −40 to +70°C [Fixed Laying] or −5 to +70°C [Flexible Application] Standard, +80°C Rated Temperature per UL Specification for Both Fixed and Flexible Installation Enabling Higher-Ambient Industrial Facilities, +90°C Conductor and +250°C Short-Circuit Capability Supporting Transient Overvoltage Conditions During Frequency Conversion Switching, UV-Resistant Outdoor Use per DIN VDE 0250, Electromagnetic Compatibility per EN 55011 / DIN VDE 0875 / EN 61800-3, Self-Extinguishing and Flame-Retardant per DIN VDE 0482-265-2-1, Insulation Resistance 200+ MΩ·km, Radiation Resistance to 80×10⁶ cJ/kg, Flexible Bending Radius Supporting Tight Drive Enclosure Routing, RoHS and CE Approved, and Complete North American VFD Infrastructure Compliance Enabling OEM Motor Drive Integration and Process Automation Acceptance with UL Market Validation)
GAALFLEX® VFD 2YSLCYK-J: CPR-Compliant (EU 305/2011 + EN 50575:2014+A1:2016, Eca Classification) Variable Frequency Drive Inverter Connection Cable for North American Industrial Motor Power Supply, Mining Applications, and Outdoor Frequency Converter Systems (0.6/1 kV Nominal Voltage, 4 kV Test Voltage, Comprehensive Dual-Configuration Portfolio [4-Core and 3+3 Earth Conductor Versions], 1.5–300 mm² Conductor Range Enabling Complete VFD Specification from Servo Drives Through Industrial Motors, Flexible Class 5 Red Copper per IEC 60228, PE Special Insulation Compound Providing Electrical Stability, Aluminum Tape + PETP Foil + Tinned Copper Braid Triple-Layer Shielding, Low Mutual Capacitance [70–410 nF/km], Low Coupling Resistance [Max 250 Ω/km], Black RAL 9005 PVC Outer Sheath with UV Resistance Enabling Outdoor Mining and Industrial Installation Without Degradation, Temperature Range −40 to +70°C [Fixed] or −5 to +70°C [Flexible Application] with +90°C Conductor and +250°C Short-Circuit Capability, Hazardous-Area Installation per DIN VDE 0250, Electromagnetic Compatibility per EN 55011 / DIN VDE 0875 / EN 61800-3, Self-Extinguishing and Flame-Retardant per DIN VDE 0482-265-2-1, CPR Fire Classification Eca [EN 13501-1] Enabling European Regulatory Compliance, Optional XLPE Halogen-Free Version [2XSLCHK-J] per IEC 60502-4 with Eca-Rated Black SHF1 Sheath, Suitable for Mining Machinery, Outdoor Industrial Systems, Automotive and Food Automation with Environmental Exposure, and Complete International VFD Infrastructure Compliance with Regulatory Mandates)

Type 2YSLCYK-J GAALFLEX® VFD

GAALFLEX® VFD 2YSLCYK-J: CPR-Compliant (EU 305/2011 + EN 50575:2014+A1:2016, Eca Classification) Variable Frequency Drive Inverter Connection Cable for North American Industrial Motor Power Supply, Mining Applications, and Outdoor Frequency Converter Systems (0.6/1 kV Nominal Voltage, 4 kV Test Voltage, Comprehensive Dual-Configuration Portfolio [4-Core and 3+3 Earth Conductor Versions], 1.5–300 mm² Conductor Range Enabling Complete VFD Specification from Servo Drives Through Industrial Motors, Flexible Class 5 Red Copper per IEC 60228, PE Special Insulation Compound Providing Electrical Stability, Aluminum Tape + PETP Foil + Tinned Copper Braid Triple-Layer Shielding, Low Mutual Capacitance [70–410 nF/km], Low Coupling Resistance [Max 250 Ω/km], Black RAL 9005 PVC Outer Sheath with UV Resistance Enabling Outdoor Mining and Industrial Installation Without Degradation, Temperature Range −40 to +70°C [Fixed] or −5 to +70°C [Flexible Application] with +90°C Conductor and +250°C Short-Circuit Capability, Hazardous-Area Installation per DIN VDE 0250, Electromagnetic Compatibility per EN 55011 / DIN VDE 0875 / EN 61800-3, Self-Extinguishing and Flame-Retardant per DIN VDE 0482-265-2-1, CPR Fire Classification Eca [EN 13501-1] Enabling European Regulatory Compliance, Optional XLPE Halogen-Free Version [2XSLCHK-J] per IEC 60502-4 with Eca-Rated Black SHF1 Sheath, Suitable for Mining Machinery, Outdoor Industrial Systems, Automotive and Food Automation with Environmental Exposure, and Complete International VFD Infrastructure Compliance with Regulatory Mandates)
GAALFLEX® VFD 2YSLCY-J: Shielded Variable Frequency Drive Inverter Connection Cable for North American Industrial Motor Power Supply and Frequency Converter Applications (0.6/1 kV Nominal Voltage, 4 kV Test Voltage, Comprehensive Dual-Configuration Portfolio [4-Core and 3+3 Earth Conductor Versions], 1.5–300 mm² Conductor Range Enabling Complete VFD System Specification from Small Servo Drives Through High-Power Industrial Motor Systems, Flexible Class 5 Red Copper per IEC 60228 Enabling Field Installation and Drive Enclosure Routing, PE Special Insulation Compound Providing Electrical Stability Across Frequency Conversion Environments, Aluminum Tape + PETP Foil + Tinned Copper Braid Triple-Layer Shielding Providing Effective EMI Suppression and Signal Integrity Critical for Frequency Converter Control, Low Mutual Capacitance [70–410 nF/km Depending on Configuration] Minimizing Cross-Talk Between Adjacent Conductors in Bundled VFD Installations, Low Coupling Resistance [Max 250 Ω/km] Supporting Low-Impedance Control Circuits, Transparent or Transparent-Orange PVC Outer Sheath Enabling Visual Conductor Inspection and Installation Verification, Temperature Range −40 to +70°C [Fixed Laying] or −5 to +70°C [Flexible Application] with +90°C Conductor and +250°C Short-Circuit Capability Supporting Transient Overvoltage Conditions During Frequency Conversion Switching, Hazardous-Area Installation Capability per DIN VDE 0250, Electromagnetic Compatibility per EN 55011 / DIN VDE 0875 / EN 61800-3 Enabling Integration with Modern Frequency Converter Installations, Self-Extinguishing and Flame-Retardant per DIN VDE 0482-265-2-1, Insulation Resistance 200+ MΩ·km, Radiation Resistance to 80×10⁶ cJ/kg, Flexible Bending Radius Supporting Tight Drive Enclosure Routing, Optional XLPE Halogen-Free Version [2XSLCH-J] for Environmental Applications, and Complete North American VFD Infrastructure Compliance Enabling OEM Motor Drive Integration and Process Automation Acceptance)

Type 2YSLCY-J GAALFLEX® VFD

GAALFLEX® VFD 2YSLCY-J: Shielded Variable Frequency Drive Inverter Connection Cable for North American Industrial Motor Power Supply and Frequency Converter Applications (0.6/1 kV Nominal Voltage, 4 kV Test Voltage, Comprehensive Dual-Configuration Portfolio [4-Core and 3+3 Earth Conductor Versions], 1.5–300 mm² Conductor Range Enabling Complete VFD System Specification from Small Servo Drives Through High-Power Industrial Motor Systems, Flexible Class 5 Red Copper per IEC 60228 Enabling Field Installation and Drive Enclosure Routing, PE Special Insulation Compound Providing Electrical Stability Across Frequency Conversion Environments, Aluminum Tape + PETP Foil + Tinned Copper Braid Triple-Layer Shielding Providing Effective EMI Suppression and Signal Integrity Critical for Frequency Converter Control, Low Mutual Capacitance [70–410 nF/km Depending on Configuration] Minimizing Cross-Talk Between Adjacent Conductors in Bundled VFD Installations, Low Coupling Resistance [Max 250 Ω/km] Supporting Low-Impedance Control Circuits, Transparent or Transparent-Orange PVC Outer Sheath Enabling Visual Conductor Inspection and Installation Verification, Temperature Range −40 to +70°C [Fixed Laying] or −5 to +70°C [Flexible Application] with +90°C Conductor and +250°C Short-Circuit Capability Supporting Transient Overvoltage Conditions During Frequency Conversion Switching, Hazardous-Area Installation Capability per DIN VDE 0250, Electromagnetic Compatibility per EN 55011 / DIN VDE 0875 / EN 61800-3 Enabling Integration with Modern Frequency Converter Installations, Self-Extinguishing and Flame-Retardant per DIN VDE 0482-265-2-1, Insulation Resistance 200+ MΩ·km, Radiation Resistance to 80×10⁶ cJ/kg, Flexible Bending Radius Supporting Tight Drive Enclosure Routing, Optional XLPE Halogen-Free Version [2XSLCH-J] for Environmental Applications, and Complete North American VFD Infrastructure Compliance Enabling OEM Motor Drive Integration and Process Automation Acceptance)