Send Message
products
products
Home > products > Shipboard & Marine Cables > Feichun FM2XAAH-FFR Marine Signal And Communication Cables Enhancing Signal Integrity and Protecting Against Electromagnetic Interference (EMI) in Marine Applications

Feichun FM2XAAH-FFR Marine Signal And Communication Cables Enhancing Signal Integrity and Protecting Against Electromagnetic Interference (EMI) in Marine Applications

Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: VDE 0250 Part 813

Model Number: FM2XAAH-FFR

Payment & Shipping Terms

Minimum Order Quantity: 200 Meter

Price: 10-50 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 18,000 meters per week

Highlight:
Easy Termination:
Simplifies The Termination Process
Swift Power Transfer:
Rapid Power Distribution
Certifications:
ABS, DNV, BV, LR, GL, RINA, NK, CCS
Shielding Material:
Aluminum/Polyester Tape
Operating Temperature:
-40°C To 90°C
Tensile Strength:
5000 Lbs
Insulation Material:
XLPE
Flexibility:
Class 5 (IEC 60228)
High Voltage Capacity:
Robust Pressure Resistance Design
Chemical Resistance:
Chemically Resilient
Shielded:
Yes
Bend Radius:
10 Inches
Conductor Material:
Copper
Armour Type:
Galvanized Steel Wire Braid
Easy Termination:
Simplifies The Termination Process
Swift Power Transfer:
Rapid Power Distribution
Certifications:
ABS, DNV, BV, LR, GL, RINA, NK, CCS
Shielding Material:
Aluminum/Polyester Tape
Operating Temperature:
-40°C To 90°C
Tensile Strength:
5000 Lbs
Insulation Material:
XLPE
Flexibility:
Class 5 (IEC 60228)
High Voltage Capacity:
Robust Pressure Resistance Design
Chemical Resistance:
Chemically Resilient
Shielded:
Yes
Bend Radius:
10 Inches
Conductor Material:
Copper
Armour Type:
Galvanized Steel Wire Braid
Feichun FM2XAAH-FFR Marine Signal And Communication Cables Enhancing Signal Integrity and Protecting Against Electromagnetic Interference (EMI) in Marine Applications

Feichun FM2XAAH-FFR Marine Signal and Communication Cables

 

Enhancing Signal Integrity and Protecting Against Electromagnetic Interference (EMI) in Marine Applications

 

 

 

 

Feichun FM2XAAH-FFR marine cables are designed specifically for signal and communication systems in marine environments, such as radar, radio, and information systems.

 

 

 

Feichun FM2XAAH-FFR Marine Signal And Communication Cables Enhancing Signal Integrity and Protecting Against Electromagnetic Interference (EMI) in Marine Applications 0

 

 

 

 

These cables are engineered to provide:

 

 

 

 

Reliable high-frequency signal transmission through twisted-pair construction.

 

 

 

 

 

Exceptional protection against electromagnetic interference (EMI) using individual and overall screening.

 

 

 

 

 

High durability under harsh marine conditions, with halogen-free, flame-retardant outer sheaths.

 

 

 

 

 

This article will provide detailed insights into the cable’s construction, specifications, applications, and installation best practices, ensuring safe and efficient use.

 

 

 

 


 

Technical Specifications

 

 

1. Construction Details

 

 

 

 

 

Component Material/Design Standards
Conductor Electrolytic, stranded, annealed copper wire (IEC 60228 Class 2/5, tinned on request) IEC 60228
Fire Barrier Mica tape for fire resistance IEC 60331
Insulation Cross-linked polyethylene (XLPE); cores numbered black and white IEC 60092-360
Separator Foil for individual and overall pairs IEC 60092
Individual Screen Aluminum tape with tinned copper drain wire IEC 60092
Overall Screen Aluminum tape with tinned copper drain wire IEC 60092
Outer Sheath Halogen-free, flame-retardant, UV-resistant polyolefin (SHF1) IEC 60092-376, IEC 60754
Color Orange or Green  

 

 

2. Performance Parameters

 

 

 

 

Property Value Standards
Operating Voltage 150/250V IEC 60092-350
Test Voltage 1.5 kV IEC 60092
Working Temperature -40°C to +90°C IEC 60811-403
Minimum Bending Radius 6×D (fixed installation) IEC 60092
UV Resistance EN 50289-4-17 A&B, ISO 4892-2&3  

 

 

 

3. Cross-Section and Electrical Data

 

 

 

 

Cross Section (mm²) Overall Diameter (mm) Approx. Weight (kg/km) Min. Bending Radius (mm) Max Resistance (Ohm/km) Current Capacity (A)
2x2x0.5 11.2 112 68 40.4 9.4
4x2x0.5 13 168 78 40.4 9.4
7x2x0.5 15.6 258 94 40.4 9.4
2x2x1.5 15.3 195 92 12.8 17.4
4x2x1.5 18.1 318 109 12.8 17.4

 

 

 

Advantages

 

 

 

Signal Integrity:

 


Twisted pairs ensure stable high-frequency transmission, reducing signal distortion.

 

 

 

 

EMI Protection:

 


Individual and overall screens shield against environmental electromagnetic interference.

 

 

 

 

Fire Resistance:

 


Mica tape fire barriers provide IEC 60331 compliance, ensuring circuit integrity during fires.

 

 

 

 

Halogen-Free Design:

 


Safe for use in confined spaces with minimal toxic smoke emission during fires.

 

 

 

 

Durability:

 


UV-resistant and halogen-free polyolefin sheath ensures long-term reliability.

 

 

 


 

Feichun FM2XAAH-FFR Marine Signal And Communication Cables Enhancing Signal Integrity and Protecting Against Electromagnetic Interference (EMI) in Marine Applications 1

 

 

Marine Applications

 

 

 

1. Radio and Radar Systems

 

 

 

  • Provides consistent signal quality for reliable communication and navigation.

 

 

  • Ensures protection against EMI in high-frequency environments.

 

 

 

 

 

 

2. Information Systems

 

 

 

  • Supports data networks for on-board systems.

 

 

 

  • Ideal for redundancy and performance monitoring in critical marine operations.

 

 

 


 

 

Feichun FM2XAAH-FFR Marine Signal And Communication Cables Enhancing Signal Integrity and Protecting Against Electromagnetic Interference (EMI) in Marine Applications 2

 

Installation Best Practices

 

 

 

1. Cable Routing

 

 

 

Installation Aspect Recommendation
Bend Radius Minimum 6×D for fixed installations
Separation from Power Maintain adequate separation to prevent interference
Support Systems Use proper cable trays or conduits to prevent sagging

 

 

 

2. EMC Considerations

 

 

 

 

Parameter Best Practice
Screen Termination Ensure effective grounding for EMI shielding effectiveness
Separation Maintain clearances to minimize crosstalk and interference

 

 

 

 

 


 

 

Feichun FM2XAAH-FFR Marine Signal And Communication Cables Enhancing Signal Integrity and Protecting Against Electromagnetic Interference (EMI) in Marine Applications 3

 

Fire and Environmental Safety

 

 

 

 

Feature Standard Benefit
Flame Retardance IEC 60332-1, IEC 60332-3 Limits flame propagation
Halogen-Free Materials IEC 60754-1, IEC 60754-2 Reduces toxic smoke emissions
UV Resistance EN 50289-4-17 Prolongs lifespan in sunlight

 

 

 

Troubleshooting Common Issues

 

 

 

 

1. Signal Loss

 

 

 

 

Cause: Poor terminations or damaged screens.

 

 


Solution: Check and repair termination points. Verify screen integrity.

 

 

 

 

2. Environmental Damage

 

 

 

Cause: UV or moisture exposure.

 

 


Solution: Inspect outer sheath for wear and consider protective coverings.

 

 


 

Conclusion

 

 

 

The Feichun FM2XAAH-FFR marine cables provide unparalleled signal clarity, EMC protection, and durability under extreme marine conditions.

 

 

 

 

 

By following proper installation guidelines and leveraging their robust design, these cables ensure the safety and efficiency of critical communication systems on marine vehicles.

 

 

 

 

For more technical data, contact Feichun Cable today!

 

 

 

 

 

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

 

 

 

 

 

 

 

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.