Send Message
products
products
Home > products > Shipboard & Marine Cables > Feichun Type FM2XAH-FFR Marine Communication Cable: Technical Guide and Implementation

Feichun Type FM2XAH-FFR Marine Communication Cable: Technical Guide and Implementation

Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: VDE 0250 Part 813

Model Number: FM2XAH-FFR

Payment & Shipping Terms

Minimum Order Quantity: 200 Meter

Price: 10-30 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 18,000 meters per week

Highlight:
Weather Resistance:
Resilient In Diverse Weather
Model:
Corrosion-Proof Marine Cable
Bending Radius:
5 Times Cable Diameter
Voltage:
0.6/1kV
Uv Stability:
UV Stable Structure
Oil Resistance:
Yes
Sturdy Connector Design:
Solid Connector Construction
Easy Installation Process:
Easy To Install
Temperature Rating:
-40°C To 90°C
Reliable Transmission:
Ensures Consistent Power Transmission
Waterproof Design:
Water-Resistant Construction
Operating Temperature:
-40°C To +90°C
Flame Retardant:
Yes
Application:
Marine Environments
Weather Resistance:
Resilient In Diverse Weather
Model:
Corrosion-Proof Marine Cable
Bending Radius:
5 Times Cable Diameter
Voltage:
0.6/1kV
Uv Stability:
UV Stable Structure
Oil Resistance:
Yes
Sturdy Connector Design:
Solid Connector Construction
Easy Installation Process:
Easy To Install
Temperature Rating:
-40°C To 90°C
Reliable Transmission:
Ensures Consistent Power Transmission
Waterproof Design:
Water-Resistant Construction
Operating Temperature:
-40°C To +90°C
Flame Retardant:
Yes
Application:
Marine Environments
Feichun Type FM2XAH-FFR Marine Communication Cable: Technical Guide and Implementation

Feichun Type FM2XAH-FFR Marine Communication Cable: Technical Guide and Implementation

 

The Feichun Type FM2XAH-FFR is an advanced marine-grade cable designed specifically for signal and communication systems on maritime vessels.

 

Its unique construction features make it ideal for use in radio systems, radar equipment, and information networks on ships.

 

 

Feichun Type FM2XAH-FFR Marine Communication Cable: Technical Guide and Implementation 0

 

By combining twisted pairs for optimal high-frequency signal transmission and overall screening to minimize environmental electromagnetic interference (EMI), this cable ensures reliable performance in demanding marine environments.

 

 

 

1.2 Key Applications

 

 

The FM2XAH-FFR cable is suited for:

 

 

  • Marine communication systems, including radio and intercoms.

 

  • Radar installations, requiring high signal fidelity.

 

  • Information systems, facilitating networked data communication.

 

  • Control systems on maritime vessels, where precise signal transmission is vital.

 

 


2. Technical Specifications

 

 

2.1 Construction Features

 

 

 

Component Material/Specification Purpose
Conductor Electrolytic, stranded annealed copper wire (IEC 60228 Class 2) Ensures excellent electrical conductivity and flexibility.
Fire Barrier Mica tape Provides fire resistance and circuit integrity in high-temperature conditions.
Insulation Cross-linked polyethylene (XLPE) compound Delivers high dielectric strength and durability in marine environments.
Screen Tinned copper drain wire and aluminum tape overall screen Protects against EMI, ensuring clean signal transmission.
Outer Sheath Halogen-free, flame-retardant polyolefin-based compound (SHF1) Ensures environmental safety, flame retardance, and UV resistance.
Color Options Orange or Green Allows for easy identification during installation and maintenance.

 

 

2.2 Performance Parameters

 

 

Parameter Specification
Operating Temperature Range -40°C to +90°C
Minimum Installation Temp. -15°C
Rated Voltage 150/250V
Test Voltage 1.5 kV
Bending Radius (Fixed) 6 × Cable Diameter

 

 

 

 


3. Compliance and Certification

 

 

3.1 Construction Standards

 

 

  • IEC 60092/376: Electrical installations in ships.

 

  • IEC 60092/350-360: Testing and material standards for shipboard cables.

 

 

3.2 Safety Certifications

 

 

Feature Standard Benefit
Flame Retardance IEC 60332/1, IEC 60332/3-22 Cat A Limits fire spread in emergency conditions.
Fire Resistance IEC 60331/21, IEC 60331/1-2 Maintains circuit integrity during fire.
Halogen-Free IEC 60754/1-2 Reduces toxicity and corrosion during combustion.
Smoke Emission IEC 61034/1-2 Enhances visibility and safety in fire scenarios.
UV Resistance EN 50289-4-17 A&B, ISO 4892-2&3 Ensures performance in outdoor marine environments.

 

Feichun Type FM2XAH-FFR Marine Communication Cable: Technical Guide and Implementation 1

 

 

 

 

4. Installation Guidelines

 

 

4.1 Pre-Installation Considerations

 

 

Ensure installation temperature is above -15°C to prevent damage to cable integrity.

 

 

Confirm the cable's minimum bending radius (6 × D) is maintained during installation.

 

 

Use proper tools to handle the cable drum and prevent damage.

 

 

Ground all screening layers correctly to minimize EMI.

 

 

 

4.2 Common Installation Challenges

 

 

Challenge Solution Prevention
Cold Weather Installation Heat installation area temporarily if below -15°C Schedule installation during warmer periods.
EMI Interference Proper grounding and separation of cables. Follow manufacturer’s EMI guidelines.
Physical Damage Use edge-protected cable trays. Inspect cable trays and installation paths.

 

5. Size Selection Guide

 

 

5.1 Available Configurations

 

 

 

Configuration Overall Diameter (mm) Weight (kg/km) Min. Bending Radius (mm) Max Resistance (Ω/km)
1x2x0.5 6.6 50 40 40.4
2x2x0.5 9.6 85 58 40.4
4x2x0.5 11.3 130 68 40.4
7x2x0.5 13.3 190 80 40.4
12x2x0.5 17.8 310 107 40.4

 

 

5.2 Selection Criteria

 

 

  • Evaluate signal frequency requirements and ensure impedance compatibility.

 

  • Account for environmental EMI levels in the installation area.

 

  • Determine the required number of pairs based on the application.

 

  • Ensure sufficient space for routing cables in tight shipboard installations.

 

 


6. Maintenance and Troubleshooting

 

 

6.1 Preventive Maintenance

 

 

  • Regularly inspect the outer sheath for physical damage or UV degradation.

 

  • Perform insulation resistance testing annually to ensure electrical integrity.

 

  • Check continuity of the screening system to verify EMI protection.

 

 

 

6.2 Common Issues and Resolution

 

 

Issue Cause Resolution
Signal Degradation Faulty terminations or EMI Repair connections; verify screening system.
Interference Insufficient grounding Ensure proper grounding of screens.
Physical Damage Improper handling or routing Replace damaged sections; inspect pathways.

 

Feichun Type FM2XAH-FFR Marine Communication Cable: Technical Guide and Implementation 2

 

7. Benefits of Feichun Type FM2XAH-FFR

 

 

High Signal Integrity: Twisted pairs and robust screening ensure clear, high-frequency transmissions.

 

 

Fire Resistance: Mica tape and flame-retardant outer sheath provide superior fire safety.

 

 

Environmental Durability: Resistant to UV, salt spray, and harsh marine conditions.

 

 

Low Smoke, Halogen-Free: Minimizes toxicity in fire scenarios, ensuring personnel safety.

 

 

 

By addressing common challenges in marine environments and offering unparalleled performance, the Feichun Type FM2XAH-FFR is the ideal choice for modern maritime communication needs.