Product Details
Place of Origin: Hefei Anhui China
Brand Name: FeiChun™
Certification: VDE 0250 Part 813
Model Number: Type MGG Marine Cables
Payment & Shipping Terms
Minimum Order Quantity: 800 Meter
Price: 10-30 USD per meter, price varies according to specifications
Packaging Details: Cable Reels or Packaging Bags
Delivery Time: 15-30 Work Day
Payment Terms: T/T, Western Union
Supply Ability: 18,000 meters per week
Outstanding Durability: |
Durable And Reliable |
Flexible And Durable: |
Flexible And Long-lasting Construction |
Permissible Tensile Fore: |
MAX 2250 N |
Swift Power Transfer: |
Rapid Power Distribution |
Safety Certifications: |
Certified For Safety |
Flexible: |
Yes |
High Voltage Capacity: |
Robust Pressure Resistance Design |
Weather Resistance: |
Resilient In Diverse Weather |
Armor: |
Galvanized Steel Wire, Aluminum Interlocked Armor |
Easy Termination: |
Simplifies The Termination Process |
Standards: |
NEC, NFPA 70 |
Application: |
Marine And Offshore Installations, Ships, And Other Marine Vessels |
Water Resistant: |
Yes |
Cable Type: |
Flexible |
Outstanding Durability: |
Durable And Reliable |
Flexible And Durable: |
Flexible And Long-lasting Construction |
Permissible Tensile Fore: |
MAX 2250 N |
Swift Power Transfer: |
Rapid Power Distribution |
Safety Certifications: |
Certified For Safety |
Flexible: |
Yes |
High Voltage Capacity: |
Robust Pressure Resistance Design |
Weather Resistance: |
Resilient In Diverse Weather |
Armor: |
Galvanized Steel Wire, Aluminum Interlocked Armor |
Easy Termination: |
Simplifies The Termination Process |
Standards: |
NEC, NFPA 70 |
Application: |
Marine And Offshore Installations, Ships, And Other Marine Vessels |
Water Resistant: |
Yes |
Cable Type: |
Flexible |
When it comes to ensuring uninterrupted power for marine vehicles and equipment, choosing the right cable is crucial. Feichun, a leader in the design and manufacture of specialised cables, offers the Type MGG cable, purpose-built for fixed installations in electromechanical and electronic equipment on marine vehicles.
This cable stands out for its robust construction, excellent oil resistance, UV resistance, and ability to endure the harsh marine environment.
This article dives into the technical details, applications, installation best practices, and challenges of the Feichun Type MGG cable, helping you make an informed decision for your marine power needs.
The Feichun Type MGG cable is designed to meet the most rigorous marine standards, ensuring its suitability for demanding environments:
These certifications ensure the safety, durability, and reliability of the cable under extreme conditions.
Feature | Specification |
---|---|
Conductor Material | Electrolytic, stranded, annealed copper wire (IEC 60228 Class 2 or Class 5; tinned available) |
Insulation Material | HF HEPR (Halogen-Free Heat Resistant Ethylene Propylene Rubber) |
Bedding Material | Rubber for added mechanical protection and flexibility |
Outer Sheath Material | Chloroprene-based (SE1), flame retardant, UV-resistant, and oil-resistant |
Rated Voltage | 0.6/1 kV |
Test Voltage | 3.5 kV |
Working Temperature | -40°C to +90°C |
Minimum Bending Radius | 6 x Overall Diameter |
Conductor:
Class 2 Copper: More rigid, suitable for fixed installations.
Class 5 Copper: Highly flexible, ideal for environments requiring frequent movement.
Tinned Copper: Provides corrosion resistance and enhanced conductivity, critical for marine applications.
Insulation:
Made of Halogen-Free Heat Resistant Ethylene Propylene Rubber (HF HEPR), ensuring:
Excellent electrical properties.
Resistance to ozone, chemicals, and weathering.
Retention of flexibility even at low temperatures.
Outer Sheath:
Chloroprene (Neoprene): Delivers exceptional protection against:
Oil and chemical exposure.
UV degradation and harsh weather.
Abrasion and mechanical stress.
Proper installation is critical to the cable’s performance and longevity. Below are best practices for installation:
Avoid routes where the cable could face:
Extreme temperatures.
Chemical spills.
Vibration or abrasion.
Cable Diameter (mm) | Minimum Bending Radius (mm) |
---|---|
10 | 60 |
20 | 120 |
30 | 180 |
Failure to follow this guideline can cause damage to the conductors, insulation, or outer sheath.
Protect cables from:
Sharp edges during installation.
Impact from heavy equipment.
Prolonged exposure to abrasives or corrosive chemicals.
Marine environments present unique challenges that can affect cable performance. Here’s a guide to diagnosing and addressing common problems:
Issue | Potential Cause | Solution |
---|---|---|
Sheath Damage | Abrasion, impact, or chemical exposure | Inspect regularly, apply protective coverings. |
Insulation Failure | Excessive bending, mechanical stress | Adhere to bending radius, avoid over-tightening connections. |
Corrosion | Saltwater ingress through damaged sheath | Use tinned copper conductors and repair sheath promptly. |
Flame Propagation | Exposure to fire or extreme heat | Ensure compliance with IEC 60332 flame retardation tests. |
Feichun’s Type MGG marine cables are engineered to provide robust and reliable power solutions for demanding marine environments. Their construction, material quality, and adherence to international standards make them the ideal choice for various applications.
Whether you’re outfitting a commercial vessel or industrial marine equipment, Feichun Type MGG cables offer unmatched durability, safety, and performance. Contact Feichun today to learn more about custom solutions tailored to your needs.
For detailed specifications or further assistance, reach out to our experts. Empower your marine operations with Feichun!
Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.