Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: VDE 0250 Part 814

Model Number: FMGCH-FFR

Payment & Shipping Terms

Minimum Order Quantity: 200 Meter

Price: 10-30 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 16,000 meters per week

Highlight:
Abrasion Resistance:
High
Flame Retardant:
Yes
Sturdy Connector Design:
Solid Connector Construction
Armour Type:
Galvanized Steel Wire Braid
Underground Ready:
Suited For Underground Mining
Shielded:
Yes
Easy Installation Process:
Easy To Install
Standards:
IEC, IEEE, UL, CSA, NEK, BS, AS
Impact Resistant:
Guards Against Impact Damage
Uv Stability:
UV Stable Structure
Optimized For Quarrying:
Designed For Quarrying Applications
Outstanding Durability:
Durable And Reliable
Application:
Marine And Offshore Installations
Length:
Customizable
Abrasion Resistance:
High
Flame Retardant:
Yes
Sturdy Connector Design:
Solid Connector Construction
Armour Type:
Galvanized Steel Wire Braid
Underground Ready:
Suited For Underground Mining
Shielded:
Yes
Easy Installation Process:
Easy To Install
Standards:
IEC, IEEE, UL, CSA, NEK, BS, AS
Impact Resistant:
Guards Against Impact Damage
Uv Stability:
UV Stable Structure
Optimized For Quarrying:
Designed For Quarrying Applications
Outstanding Durability:
Durable And Reliable
Application:
Marine And Offshore Installations
Length:
Customizable
Ensuring Critical Communication During Fire: A Comprehensive Guide to Feichun Type FMGCH-FFR Fire-Resistant and Shielded Marine Communication Cables

Ensuring Critical Communication During Fire: A Comprehensive Guide to Feichun Type FMGCH-FFR Fire-Resistant and Shielded Marine Communication Cables

 

Maintaining Vital Links: Understanding Feichun Type FMGCH-FFR Fire-Resistant Shielded Marine Communication Cables

 

 

When safety, reliability, and uninterrupted communication are paramount, Feichun Type FMGCH-FFR fire-resistant marine communication cables stand out as the ultimate solution. Designed to meet the demands of control and communication systems aboard marine vehicles, these cables ensure consistent performance even in the most challenging environments.

 

 

 

Ensuring Critical Communication During Fire: A Comprehensive Guide to Feichun Type FMGCH-FFR Fire-Resistant and Shielded Marine Communication Cables 0

 

 

 

 

 

Feichun, a leader in marine cable solutions, specializes in crafting high-quality cables for critical systems such as radio, radar, and information networks.

 

 

 

 

The Type FMGCH-FFR cable is engineered to maintain signal integrity during fires, thanks to its twisted pair construction, which optimizes high-frequency signal transmission, and its overall screened design, which minimizes electromagnetic interference (EMI).

 

 

 

This article provides a comprehensive guide to the features, specifications, installation practices, and troubleshooting processes for the FMGCH-FFR cable, equipping you with the knowledge to ensure safety and reliability on board.

 

 


II. Technical Specifications and Standards Compliance

 

 

Engineered for Survival: Technical Specifications and Standards

 

 

Feichun Type FMGCH-FFR cables are built to stringent standards, ensuring unparalleled performance in marine applications. Here’s a closer look:

 

 

 

Feature Details
Conductor Electrolytic, stranded, annealed copper wire (IEC 60228 Class 2 or 5, tinned on request). Provides durability and high-frequency performance.
Separator Mica tape, ensuring fire-resistant insulation integrity under extreme temperatures.
Insulation Halogen-Free Heat Resistant Ethylene Propylene Rubber (HF HEPR).
Layup Twisted pairs for reduced electromagnetic interference and crosstalk.
Screen Electrolytic copper braided screen with 90% coverage for effective EMI shielding.
Outer Sheath Halogen-free, flame retardant, UV-resistant, thermoplastic polyolefin compound.
Colour Green, commonly used to indicate fire-resistant circuits.
Rated Voltage 60/250 V.
Temperature Range -40°C to +90°C.
Bending Radius Minimum 8 x cable diameter for safe handling.

 

 


Compliance with International Standards

 

 

The FMGCH-FFR cable meets or exceeds the following standards:

 

 

  • Construction Standards: IEC 60092/375-376.

 

  • Testing and Material Standards: IEC 60092/350-351-359.

 

  • Fire Resistance: IEC 60331, ensuring circuit integrity during fire exposure.

 

 

Ensuring Critical Communication During Fire: A Comprehensive Guide to Feichun Type FMGCH-FFR Fire-Resistant and Shielded Marine Communication Cables 1

 

Key Benefits of Materials and Design

 

Conductor and Insulation

 

 

  • Class 2 vs. Class 5 Conductors: Class 2 conductors provide rigidity and durability, while Class 5 enhances flexibility.

 

  • Mica Tape: Acts as a thermal barrier, maintaining insulation integrity during high-temperature fires.

 

  • HF HEPR Insulation: Ensures low smoke emissions, chemical resistance, and optimal flexibility in low temperatures.

 

 

Outer Sheath and Screening

 

  • Halogen-Free Compound: Reduces toxic fume emissions in fires, enhancing safety for personnel.

 

  • UV Resistance: Ensures longevity in outdoor or sun-exposed installations.

 

  • Electrolytic Copper Screen: Offers 90% shielding efficiency, protecting against EMI that could disrupt critical communications.

 

 

 


III. Installation Guidelines and Best Practices

 

 

Installation for Optimal Performance and Safety

 

 

Proper installation is crucial to achieving the maximum performance and safety of the FMGCH-FFR cable. Follow these guidelines:

 

 

Cable Handling

 

  • Avoid kinking or excessive bending, especially near the mica tape insulation and screened layers, as this can compromise their effectiveness.

 

Routing Recommendations

 

 

  • Minimize exposure to potential fire hazards by selecting fire-safe routes.

 

  • Separate the cable from high-voltage power lines and other EMI sources.

 

  • Use fire-resistant supports and penetrations to maintain fire compartmentation integrity.

 

 

Termination and Grounding

 

  • Employ fire-resistant connectors and glands to preserve the cable’s fire safety attributes.

 

  • Ensure proper termination of the screen to maximize EMI shielding.

 

  • Bond and ground the screen correctly to prevent electrical noise.

 

 


IV. Common Challenges and Troubleshooting

 

 

Maintaining Reliability: Troubleshooting Common Issues

 

 

 

1. Damage to Mica Tape

 

 

  • Cause: Excessive mechanical stress or mishandling during installation.

 

  • Solution: Handle cables with care and inspect for integrity before installation.

 

 

2. Screen Damage

 

  • Cause: Over-bending or sharp pulls during installation.

 

  • Impact: Reduced EMI protection, leading to signal degradation.

 

  • Solution: Adhere to the recommended bending radius of 8x the outer diameter.

 

 

 

3. Improper Terminations

 

  • Impact: Increased connection failures and reduced shielding.

 

  • Solution: Use appropriate tools and techniques for secure terminations.

 

 

 


Ensuring Critical Communication During Fire: A Comprehensive Guide to Feichun Type FMGCH-FFR Fire-Resistant and Shielded Marine Communication Cables 2

 

V. Conclusion

 

 

Reliable Communication and Control in Fire Emergencies

 

 

The Feichun Type FMGCH-FFR cable is indispensable for ensuring uninterrupted communication in critical marine systems. From its fire-resistant properties to its effective EMI shielding, every aspect of its design serves to enhance safety and reliability.

 

 

By following the recommended installation and handling practices, you can fully leverage the benefits of this advanced cable. For more details or to request a quote, contact Feichun today and ensure your marine systems are equipped with the best in the industry.

 

 


VI. Appendices (Optional)

 

 

Property Value
Conductor Material Electrolytic Copper
Insulation Material HF HEPR
Fire Standard IEC 60331
Voltage Rating 60/250 V

 

 

 

 

 

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

 

 

 

 

 

 

 

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.