Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: VDE 0250 Part 814

Model Number: MGH-FFR Marine Cables

Payment & Shipping Terms

Minimum Order Quantity: 200 Meter

Price: 8-10 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 16,000 meters per week

Highlight:
Outstanding Flexibility:
Extremely Flexible
Insulation Material:
XLPE
High Current Capability:
Efficient High-current Transmission
Standards:
IEC, IEEE, UL, CSA, NEK, BS, AS
Jacket Material:
LSZH (Low Smoke Zero Halogen)
Temperature Rating:
-40°C To +90°C
Tensile Strength:
5000 Lbs
Chemical Resistance:
Chemically Resilient
Safety Certifications:
Certified For Safety
Low Smoke Emission:
Yes
Cable Type:
Flexible
Easy Termination:
Simplifies The Termination Process
Compact Installation:
Compact Design
High Conductivity Core:
Excellent Conductivity
Outstanding Flexibility:
Extremely Flexible
Insulation Material:
XLPE
High Current Capability:
Efficient High-current Transmission
Standards:
IEC, IEEE, UL, CSA, NEK, BS, AS
Jacket Material:
LSZH (Low Smoke Zero Halogen)
Temperature Rating:
-40°C To +90°C
Tensile Strength:
5000 Lbs
Chemical Resistance:
Chemically Resilient
Safety Certifications:
Certified For Safety
Low Smoke Emission:
Yes
Cable Type:
Flexible
Easy Termination:
Simplifies The Termination Process
Compact Installation:
Compact Design
High Conductivity Core:
Excellent Conductivity
Ensuring Circuit Integrity in Fire Situations: Understanding Feichun Type MGH-FFR Marine Cables

Ensuring Circuit Integrity in Fire Situations: Understanding Feichun Type MGH-FFR Marine Cables

 

 

When it comes to marine vessels, ensuring the uninterrupted operation of critical systems during a fire can make all the difference. This is where Feichun Type MGH-FFR marine cables excel.

 

 

 

 

Designed for fixed installations in electromechanical and electronic equipment, these cables ensure circuit integrity during fire emergencies. With compliance to strict standards like IEC 60331, these cables stand out as the backbone of reliable and safe marine operations.

 

 

Ensuring Circuit Integrity in Fire Situations: Understanding Feichun Type MGH-FFR Marine Cables 0

 

 

 

 

This article provides a comprehensive overview of the Type MGH-FFR cable, including its construction, specifications, and advantages. We'll also explore best practices for installation and troubleshooting, equipping you with essential knowledge for safe and efficient cable use.

 

 


I. What Makes Feichun Type MGH-FFR Stand Out?

 

 

Feichun Cable has been a trusted name in the specialized cable industry, offering innovative solutions for demanding environments. The Type MGH-FFR is specifically engineered to maintain functionality in extreme conditions, including fires, ensuring that critical systems on marine vessels continue to operate.

 

 

 

 

 

Key Features

 

 

  • Fire Resistance: Certified to IEC 60331, providing continuous circuit functionality during a fire.

 

  • Halogen-Free: Produces minimal toxic fumes and smoke, enhancing safety for personnel and equipment.

 

  • UV Resistant: Suitable for prolonged outdoor exposure.

 

 

 

  • Mechanical Durability: Designed to withstand the rigours of marine environments, including exposure to water, chemicals, and vibrations.

 

 

 


II. Technical Specifications and Standards Compliance

 

 

 

1. Construction Standards

 

 

 

  • DIN 89160 and IEC 60092/353: Govern the design and performance requirements for shipboard and offshore cables.

 

 

 

  • IEC 60092/350-351-359: Ensure the materials meet stringent safety and reliability tests.

 

 

 

2. Material Composition

 

 

 

Component Material Key Advantages
Conductor Stranded, annealed electrolytic copper (Class 2/5) Excellent electrical conductivity; Class 5 offers superior flexibility for tight spaces.
Separator Mica tape Maintains insulation integrity at high temperatures, preventing short circuits during a fire.
Insulation Halogen-Free HEPR compound Durable, flexible, and resistant to ozone, weathering, and chemicals.
Bedding Halogen-free compound Protects inner layers and provides a cushion for better durability.
Outer Sheath Halogen-free thermoplastic polyolefin compound Flame retardant, UV resistant, and compliant with fire safety standards like IEC 60332.

 

 

3. Electrical Characteristics

 

 

Property Specification
Rated Voltage 0.6/1 kV
Test Voltage 3.5 kV

 

 

 

4. Environmental and Mechanical Properties

 

 

Property Value
Working Temperature -40°C to +90°C
Minimum Bending Radius 6 x Cable Diameter
Flame Retardation IEC 60332/1 and IEC 60332/3
Fire Resistance IEC 60331
Halogen Content IEC 60754/1–2
Smoke Density IEC 61034/1–2
UV Resistance EN 50289-4-17 A&B

 

 

 

 


III. Installation Guidelines and Best Practices

 

 

Proper installation is key to maintaining the fire-resistant properties of the Feichun Type MGH-FFR cable. Here’s how to get it right:

 

 

 

1. Handling

 

 

  • Avoid excessive bending or twisting to prevent damage to the mica tape layer, which is critical for fire resistance.

 

 

  • Use protective measures during transportation to prevent mechanical damage.

 

 

2. Routing

 

  • Minimize exposure to potential fire hazards by choosing optimal cable routes.

 

  • Use fire-resistant cable supports to maintain fire compartmentation.

 

 

Ensuring Circuit Integrity in Fire Situations: Understanding Feichun Type MGH-FFR Marine Cables 1

 

3. Termination and Connection

 

 

  • Employ fire-resistant glands and connectors to ensure reliable terminations.

 

  • Avoid loose connections, as they can fail under fire conditions.

 

 

4. Segregation of Circuits

 

  • Keep fire-resistant circuits separate from regular ones to enhance system reliability during a fire.

 

 


IV. Common Challenges and Troubleshooting

 

 

While robust, the MGH-FFR cable is not immune to issues. Below are common challenges and solutions:

 

 

 

Challenge Cause Solution
Mica Tape Damage Excessive bending or stress Follow the minimum bending radius guidelines strictly.
Sheath Damage Abrasion or environmental exposure Inspect and replace damaged sections promptly to maintain fire integrity.
Improper Terminations Loose connections or incompatible materials Use connectors designed for fire-resistant cables.
Overheating High current loads Ensure the current does not exceed the rated voltage and test regularly.

 

V. The Problems Feichun MGH-FFR Solves

 

 

1. Fire Safety in Marine Environments

 

 

  • Provides continuous operation of critical systems like navigation and communication during a fire.

 

 

  • Ensures crew safety with reduced toxic fume emissions.

 

 

 

2. Resistance to Harsh Conditions

 

  • UV resistance prevents degradation in exposed outdoor installations.

 

 

  • Halogen-free materials minimize corrosive damage to sensitive equipment.

 

 

3. Compliance with International Standards

 

  • Reduces the risk of non-compliance during inspections.

 

  • Guarantees compatibility with global safety protocols.

 

 


VI. Conclusion

 

The Feichun Type MGH-FFR marine cable is an indispensable component for marine vessels prioritizing safety and reliability. Its fire-resistant properties, adherence to international standards, and robust construction make it a trusted choice for critical applications.

 

 

For more information or to discuss your specific cabling needs, contact Feichun Cable today. Let us help you safeguard your operations and maintain circuit integrity in any situation.

 

 


Appendices

 

Glossary

 

  • IEC 60331: Standard specifying fire resistance requirements.

 

  • Halogen-Free: Materials that release minimal toxic fumes when burned.

 

 

Technical Data Sheet

 

Property Value
Voltage Rating 0.6/1 kV
Fire Resistance IEC 60331

 

 

 

 

This comprehensive guide ensures you understand the value and proper use of Feichun Type MGH-FFR cables.

 

 

 

 

 

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

 

 

 

 

 

 

 

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.