Send Message
products
products
Home > products > Shipboard & Marine Cables > Ensuring Reliable Data Transmission: A Comprehensive Guide to Feichun Type FMGCH Marine Communication and Control Cables

Ensuring Reliable Data Transmission: A Comprehensive Guide to Feichun Type FMGCH Marine Communication and Control Cables

Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: VDE 0250 Part 813

Model Number: FMGCH Marine Communication and Control Cable

Payment & Shipping Terms

Minimum Order Quantity: 200 Meter

Price: 10-50 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 18,000 meters per week

Highlight:
Features:
Flexible, Oil And Sunlight Resistant
Impact Resistant:
Guards Against Impact Damage
Flexible And Durable:
Flexible And Long-lasting Construction
Maximum Ampacity:
170 Amps
Connector Type:
NEMA L5-30P
High Voltage Capacity:
Robust Pressure Resistance Design
Application:
Marine And Offshore Industry
Permissible Tensile Fore:
MAX 2250 N
Sturdy Connector Design:
Solid Connector Construction
Low Smoke Emission:
Emits Minimal Smoke
Conductor Integrity:
Reliable Conductor Integrity
Voltage:
0.6/1kV
Resistance:
Oil, Chemicals, Abrasion
Flexible:
Yes
Features:
Flexible, Oil And Sunlight Resistant
Impact Resistant:
Guards Against Impact Damage
Flexible And Durable:
Flexible And Long-lasting Construction
Maximum Ampacity:
170 Amps
Connector Type:
NEMA L5-30P
High Voltage Capacity:
Robust Pressure Resistance Design
Application:
Marine And Offshore Industry
Permissible Tensile Fore:
MAX 2250 N
Sturdy Connector Design:
Solid Connector Construction
Low Smoke Emission:
Emits Minimal Smoke
Conductor Integrity:
Reliable Conductor Integrity
Voltage:
0.6/1kV
Resistance:
Oil, Chemicals, Abrasion
Flexible:
Yes
Ensuring Reliable Data Transmission: A Comprehensive Guide to Feichun Type FMGCH Marine Communication and Control Cables

Ensuring Reliable Data Transmission: A Comprehensive Guide to Feichun Type FMGCH Marine Communication and Control Cables

 

 

Safeguarding Critical Communications: Understanding Feichun Type FMGCH Marine Cables

 

 

In the challenging and often unpredictable marine environment, reliable communication and control systems are essential for safe and efficient operations. Feichun, a leader in specialised cable manufacturing, offers the Type FMGCH cable, a high-performance solution designed specifically for marine applications.

 

 

Ensuring Reliable Data Transmission: A Comprehensive Guide to Feichun Type FMGCH Marine Communication and Control Cables 0

 

 

The Feichun Type FMGCH cable excels in radio, radar, and information systems for marine vehicles, ensuring precise control and clear communication.

 

 

With twisted pairs enabling proper transmission of high-frequency signals and an overall screen that minimizes electromagnetic interference (EMI), this cable is a dependable choice for critical maritime applications.

 

 

 

 

This guide delves into the technical construction, specifications, installation practices, and troubleshooting tips for the FMGCH cable, offering valuable insights to engineers, shipbuilders, and marine operators.

 

 

 


II. Technical Specifications and Standards Compliance

 

 

Meeting Stringent Marine Communication Standards: Technical Specifications

 

 

1. Construction Standards and Compliance

 

 

The Feichun Type FMGCH cable is manufactured according to IEC 60092/376, which governs the construction and performance of marine communication cables.

 

 

Additionally, the following standards ensure the cable meets rigorous safety and performance criteria:

 

 

  • IEC 60092/350-351-359: Covering electrical, mechanical, and environmental tests.

 

  • IEC 60228: Governing conductor material and construction.

 

 

2. Detailed Construction

 

 

Component Material/Specification Purpose
Conductor Electrolytic, stranded, annealed copper (Class 2 or 5; tinned on request) Ensures excellent conductivity and corrosion resistance.
Insulation HF HEPR compound (halogen-free, heat-resistant) Provides electrical integrity, flexibility, and chemical resistance.
Separator Separating foil below the screen Offers electrical isolation and prevents screen damage.
Screen Electrolytic copper braided (90% coverage) Shields against EMI, ensuring signal clarity.
Outer Sheath Halogen-free, flame-retardant, UV-resistant thermoplastic polyolefin Ensures durability, fire safety, and weather resistance.

 

3. Key Features and Benefits

 

 

  • Twisted Pairs: Minimize crosstalk and EMI, essential for high-frequency signals.

 

  • Halogen-Free Materials: Reduce toxic fumes and smoke during fires, enhancing onboard safety.

 

  • Flame Retardant: Complies with IEC 60332/1 and IEC 60332/3 Cat A for fire propagation resistance.

 

  • UV Resistance: Prolongs cable lifespan in sunlight-exposed environments.

 

 

4. Electrical and Mechanical Properties

 

 

Property Specification Significance
Rated Voltage 60/250 V Suitable for low-voltage applications.
Test Voltage 1.5 kV Ensures insulation robustness.
Working Temperature -40°C to +90°C Reliable in extreme marine conditions.
Minimum Bending Radius 12 x Cable Diameter Prevents signal degradation due to bending.
UV and Sunlight Resistance EN 50289-4-17 A&B, ISO 4892-2&3 Extends cable longevity in exposed installations.

 

5. Cable Sizing Table

 

 

 

Nominal Section (mm²) Outer Diameter (mm) Approx. Weight (kg/km) Copper Weight (kg/km)
1x2x0.50 7.6 43 5.6
2x2x0.50 9.6 103 50.2
3x2x0.50 11.0 146 67.8
6x2x0.50 14.8 239 119.6

 

Ensuring Reliable Data Transmission: A Comprehensive Guide to Feichun Type FMGCH Marine Communication and Control Cables 1

 

III. Installation Guidelines and Best Practices

 

 

Preserving Signal Integrity: Installation Best Practices for FMGCH Cables

 

 

1. Cable Handling

 

 

  • Avoid excessive bending or crushing to protect twisted pairs and the screen.

 

  • Use appropriate pulling techniques to prevent conductor or insulation damage.

 

2. Routing Recommendations

 

 

  • Maintain adequate separation from power cables to minimize interference.

 

  • Avoid sharp bends, adhering to the minimum bending radius of 12 x OD.

 

3. Termination and Connection

 

  • Use connectors designed for twisted-pair and EMC applications to ensure proper screen continuity.

 

  • Follow proper pin assignments to maintain correct pair orientation.

 

 

4. Grounding

 

  • Implement proper bonding methods for the screen to optimize EMI shielding.

 

 


IV. Common Challenges and Troubleshooting

 

Maintaining Signal Quality: Troubleshooting Common Issues

 

 

1. Twisted Pair Damage

 

  • Cause: Excessive bending or crushing.

 

  • Impact: Increased crosstalk and signal loss.

 

  • Solution: Follow proper handling and installation guidelines.

 

 

2. Screen Damage

 

  • Cause: Improper handling or mechanical stress.

 

  • Impact: Reduced EMI shielding, compromising signal clarity.

 

  • Solution: Inspect screens regularly and replace damaged sections.

 

 

3. Impedance Mismatch

 

  • Cause: Improper connections or cable damage.

 

  • Impact: Signal reflections and attenuation.

 

  • Solution: Ensure correct termination and consistent cable geometry.

 

 

 


V. Conclusion

 

Reliable Communication and Control for Critical Marine Systems

 

 

The Feichun Type FMGCH cable is a vital component for reliable communication and control in marine environments. Its twisted-pair construction ensures high-frequency signal integrity, while the robust shielding minimizes interference.

 

Compliance with marine standards guarantees safety and performance even in harsh conditions.

 

 

By adhering to best installation practices and performing regular maintenance, users can maximize the cable's reliability and lifespan.

For inquiries or to learn more about Feichun's marine cabling solutions, contact us.

 

 


VI. Appendices (Optional)

 

  • Glossary of Terms: Definitions for EMI, twisted pairs, and shielding.

 

  • Technical Data Sheet: Expanded electrical characteristics (e.g., impedance, attenuation).

 

  • Excerpts from Standards: Key requirements from IEC standards.

 

 

 

 

 

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

 

 

 

 

 

 

 

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.