Product Details
Place of Origin: Hefei Anhui China
Brand Name: FeiChun™
Certification: VDE 0250 Part 813
Model Number: MGH Marine Cables
Payment & Shipping Terms
Minimum Order Quantity: 800 Meter
Price: 10-30 USD per meter, price varies according to specifications
Packaging Details: Cable Reels or Packaging Bags
Delivery Time: 15-30 Work Day
Payment Terms: T/T, Western Union
Supply Ability: 18,000 meters per week
Easy Termination: |
Simplifies The Termination Process |
Tensile Strength: |
5000 Lbs |
Long Lifespan Assurance: |
Extended Lifespan |
Jacket Material: |
LSZH (Low Smoke Zero Halogen) |
Stranding: |
7 Strands |
Model: |
Corrosion-Proof Marine Cable |
Permissible Tensile Fore: |
MAX 2250 N |
Temperature Rating: |
-40°C To +90°C |
Outstanding Flexibility: |
Extremely Flexible |
Chemical Resistance: |
Chemically Resilient |
Insulation Material: |
XLPE Or EPR |
Water Resistance: |
IEC 60502-1, IEC 60228 |
Swift Power Transfer: |
Rapid Power Distribution |
High Voltage Capacity: |
Robust Pressure Resistance Design |
Easy Termination: |
Simplifies The Termination Process |
Tensile Strength: |
5000 Lbs |
Long Lifespan Assurance: |
Extended Lifespan |
Jacket Material: |
LSZH (Low Smoke Zero Halogen) |
Stranding: |
7 Strands |
Model: |
Corrosion-Proof Marine Cable |
Permissible Tensile Fore: |
MAX 2250 N |
Temperature Rating: |
-40°C To +90°C |
Outstanding Flexibility: |
Extremely Flexible |
Chemical Resistance: |
Chemically Resilient |
Insulation Material: |
XLPE Or EPR |
Water Resistance: |
IEC 60502-1, IEC 60228 |
Swift Power Transfer: |
Rapid Power Distribution |
High Voltage Capacity: |
Robust Pressure Resistance Design |
Marine environments are some of the harshest on Earth. Reliable electrical systems are critical for the smooth operation of marine vehicles, whether they are cargo ships, naval vessels, or luxury yachts.
Feichun Type MGH cables are specially designed to meet the rigorous demands of marine applications. From powering electromechanical equipment to controlling electronic systems, these cables ensure safe and dependable operations in challenging environments.
This guide offers an in-depth look at the features, advantages, and best practices for using Feichun Type MGH cables for fixed installations in marine vehicles.
Feichun Cable, a global leader in cable manufacturing, is renowned for delivering high-quality products tailored for demanding environments.
Feichun Type MGH marine cables are designed specifically for fixed installations in various electromechanical and electronic equipment onboard marine vehicles.
In this article, we’ll cover:
The technical construction and standards compliance of Feichun Type MGH cables.
Installation guidelines to maximize performance and durability.
Common challenges and troubleshooting tips for marine cable systems.
By the end, you’ll understand why Feichun Type MGH is the ideal choice for marine applications.
Feichun Type MGH cables are engineered to comply with DIN 89160 and IEC 60092/353 standards, ensuring reliability in marine environments. These standards encompass testing for:
Component | Material/Specification | Key Features |
---|---|---|
Conductor | Electrolytic, stranded, annealed copper wire (IEC 60228 Class 2/5) | Class 2: Offers rigidity for fixed installations. Class 5: Provides flexibility for tighter spaces. Optional tinning: Resists corrosion in humid conditions. |
Insulation | HF HEPR (Halogen-Free Heat Resistant Ethylene Propylene Rubber) | Excellent flexibility at low temperatures, high temperature resistance, and strong ozone/chemical resistance. |
Bedding | Halogen-free compound | Cushions conductors, ensures smooth outer sheath application, and enhances cable durability. |
Outer Sheath | Thermoplastic polyolefin (HM4/SHF1) | Halogen-free, flame retardant, UV resistant, and capable of withstanding sunlight and saltwater exposure. |
Characteristic | Specification |
---|---|
Rated Voltage | 0.6/1 kV |
Test Voltage | 3.5 kV |
Working Temperature | -40°C to +90°C |
Minimum Bending Radius (Fixed) | 6 x Cable Diameter |
Flame Retardation | IEC 60332/1, IEC 60332/3 Cat A |
Halogen Content | IEC 60754/1-2 |
Smoke Density | IEC 61034/1-2 |
UV Resistance | EN 50289-4-17 A&B, ISO 4892-2&3 |
To avoid mechanical damage, handle Feichun Type MGH cables with care during transportation and storage.
Mechanical Stress: Minimize bending and pressure on the cable.
Chemical Protection: Avoid prolonged contact with oils or corrosive chemicals.
Support Systems: Use cable trays or conduits for secure installation.
Adhering to the 6 x Cable Diameter rule is critical to prevent:
Waterproof Connectors: Use IP-rated terminations for marine environments.
Sealing Measures: Protect against moisture ingress.
Post-installation tests include:
Insulation Resistance Testing: Verifies insulation integrity.
Continuity Testing: Ensures no conductor breaks.
Challenge | Cause | Solution |
---|---|---|
Mechanical Damage | Improper handling or excessive bending | Use appropriate handling equipment and follow bending guidelines. |
Environmental Degradation | UV exposure, salt spray, or temperature extremes | Ensure the outer sheath material is UV-resistant and halogen-free. |
Insulation Resistance Loss | Moisture ingress or insulation cuts | Conduct regular maintenance and use proper sealing techniques. |
Connection Failures | Corrosion or improper termination | Use tinned copper conductors and IP-rated connectors. |
Investing in Feichun Type MGH cables ensures that your marine vehicles operate safely and efficiently.
Their halogen-free, flame-retardant, and UV-resistant properties make them the ideal choice for harsh environments.
For further assistance or to inquire about customization options, contact Feichun Cable today.
Nominal Cross-Section (mm²) | Outer Diameter (mm) | Approx. Weight (kg/km) | Copper Weight (kg/km) |
---|---|---|---|
1 × 1 | 4.7 | 32 | 9.6 |
1 × 25 | 10.3 | 289 | 240 |
1 × 150 | 21.2 | 1507 | 1440 |
1 × 300 | 29.2 | 3035 | 2880 |
Explore our full range of marine cables to find the perfect fit for your needs. Feichun is committed to delivering excellence, from manufacturing to installation support.
Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.