Send Message
products
products
Home > products > Shipboard & Marine Cables > Feichun SIENOPYR FR MHXCH FE 120 Fire-Resistant Marine Power Cables - Comprehensive Emergency System Application Guide

Feichun SIENOPYR FR MHXCH FE 120 Fire-Resistant Marine Power Cables - Comprehensive Emergency System Application Guide

Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: VDE 0250 Part 813

Model Number: SIENOPYR FR MHXCH FE 120 Fire-Resistant Marine Power Cables

Payment & Shipping Terms

Minimum Order Quantity: 200 Meter

Price: 10-50 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 18,000 meters per week

Highlight:
Uv Resistance:
Yes
Length:
Customizable
Standards:
NEC, NFPA 70
Jacket Material:
Neoprene
Water Resistant:
Yes
Sturdy Connector Design:
Solid Connector Construction
Voltage:
0.6/1kV
Number Of Conductors:
3
Resistance:
Oil, Chemicals, Abrasion
Flexible:
Yes
Current Rating:
1000A
Optimized For Quarrying:
Designed For Quarrying Applications
Conductor Integrity:
Reliable Conductor Integrity
Armour Type:
Galvanized Steel Wire Braid
Uv Resistance:
Yes
Length:
Customizable
Standards:
NEC, NFPA 70
Jacket Material:
Neoprene
Water Resistant:
Yes
Sturdy Connector Design:
Solid Connector Construction
Voltage:
0.6/1kV
Number Of Conductors:
3
Resistance:
Oil, Chemicals, Abrasion
Flexible:
Yes
Current Rating:
1000A
Optimized For Quarrying:
Designed For Quarrying Applications
Conductor Integrity:
Reliable Conductor Integrity
Armour Type:
Galvanized Steel Wire Braid
Feichun SIENOPYR FR MHXCH FE 120 Fire-Resistant Marine Power Cables - Comprehensive Emergency System Application Guide

Feichun SIENOPYR FR MHXCH FE 120 Fire-Resistant Marine Power Cables - Comprehensive Emergency System Application Guide

 

 

 

In the demanding world of marine and offshore installations, fire-resistant cables are critical to ensuring the integrity and safety of emergency systems. The Feichun SIENOPYR FR MHXCH FE 120 cable is engineered to provide exceptional fire resistance, enabling critical circuits to function reliably under extreme conditions.

 

 

 

 

Feichun SIENOPYR FR MHXCH FE 120 Fire-Resistant Marine Power Cables - Comprehensive Emergency System Application Guide 0

 

 

 

Designed specifically for fixed installations in all locations aboard ships and offshore units, these cables are robust, durable, and meet stringent international fire safety standards. However, it's important to note that these cables are not suitable for continuous water immersion, making proper installation planning vital.


 

 

2. Technical Specifications

 

 

 

The Feichun SIENOPYR FR MHXCH FE 120 cable boasts advanced materials and construction techniques. Below is a detailed overview of its specifications:

 

 

2.1 Cable Construction

 

 

 

Component Material Standard Compliance
Conductor Plain copper, round stranded IEC 60228 (Class 2 or 5)
Insulation Silicone rubber High-temperature resilience
Screen Copper braiding Provides excellent EMC shielding
Outer Sheath Halogen-free flame-retardant (HFFR) IEC 60092-360
Core Identification Colour-coded (HD 308 S2) Simplifies installation

 

 

2.2 Fire Performance

 

 

Feature Specification
Fire Resistance Rating FE 120 (Circuit integrity under fire conditions)
Flame Retardance IEC 60332-1-2 / IEC 60332-3-22
Low Smoke Emission IEC 61034
Halogen-Free IEC 60754-1/2

 

 

 

 

2.3 Electrical Characteristics

 

 

Parameter Value
Rated Voltage 0.6/1kV (Um: 1.2kV)
Test Voltage 3.5kV
Maximum Conductor Temp. 90°C
Short Circuit Temp. 250°C
Minimum Laying Temp. -15°C

 

 

 

 


3. Emergency System Applications

 

 

 

SIENOPYR FR MHXCH FE 120 cables are indispensable for critical emergency circuits in marine environments. Below are some typical applications:

 

 

 

3.1 Critical Systems Integration

 

 

 

  • Fire Pump Circuits: Maintain water flow for fire suppression during emergencies.

 

 

  • Emergency Lighting Systems: Illuminate escape routes, ensuring safe evacuation.

 

 

  • Evacuation Systems: Power lifeboat davits and emergency alarms.

 

 

  • Safety Communication Networks: Support reliable communication during crises.

 

 

3.2 System Design Requirements

 

 

 

  • Circuit Segregation: Reduces the risk of cascading failures.

 

 

  • Redundancy Considerations: Ensures backup systems remain functional.

 

 

  • Emergency Power Sources: Designed for connection to dedicated emergency generators.

 

 


4. Fire Safety Standards

 

 

 

 

The Feichun SIENOPYR FR MHXCH FE 120 cable complies with rigorous fire safety standards, offering unmatched protection in critical environments.

 

 

 

4.1 Fire Performance Standards

 

 

 

Standard Requirement
IEC 60332-1-2 Resistance to flame propagation
IEC 60332-3-22 Enhanced flame retardance for bundled cables
FE 120 Circuit integrity during 120 minutes of fire

 

 

 

 

 

4.2 Smoke and Toxicity

 

 

 

  • Low Smoke Emission: Reduces visibility loss during fire (IEC 61034).

 

 

  • Halogen-Free Materials: Prevents toxic gas release (IEC 60754).

 

 


5. Marine Installation Requirements

 

 

 

Marine environments demand careful installation practices to ensure long-term reliability.

 

 

 

 

5.1 Location-Specific Installation

 

 

 

  • Engine Rooms: Require flame-retardant and heat-resistant cables.

 

 

  • Escape Routes: Must use FE 120-rated cables for critical evacuation circuits.

 

 

  • Weather Decks: Use UV and ozone-resistant materials to withstand harsh conditions.

 

 

5.2 Installation Methods

 

 

Requirement Specification
Bending Radius Minimum 6 × OD
Fire-Rated Penetrations For bulkhead transitions
Support Systems Fire-resistant cable trays

 

 

 

 


6. Environmental Protection

 

 

 

These cables are built to endure harsh environmental conditions typical of marine applications.

 

 

 

6.1 Environmental Resistance

 

 

Feature Benefit
Oil Resistance Withstands exposure to lubricants (IEC 60811-404).
Ozone Resistance Prevents degradation in ozone-rich environments.
Salt Spray Protection Ensures corrosion resistance in coastal areas.
UV Protection Guards against sun exposure damage.

 

 

 

 

6.2 Temperature Management

 

 

 

Condition Maximum Performance
Normal Operation Temp. Up to 90°C
Short Circuit Temp. Up to 250°C

 

 

 

 


7. Installation Challenges and Solutions

 

 

7.1 Common Challenges

 

 

  • Maintaining fire barrier integrity during cable routing.

 

  • Ensuring EMC compliance for sensitive circuits.

 

  • Preventing moisture ingress in humid conditions.

 

7.2 Best Practice Solutions

 

 

  • Fire Zone Separation: Proper segregation reduces fire spread risk.

 

  • Support Systems: Use fire-rated trays and clamps for secure installations.

 

  • Termination Techniques: Employ EMC glands for seamless connections.

 


8. Testing and Verification

 

 

 

8.1 Pre-Installation Testing

 

 

 

  • Fire Resistance Testing: Ensures compliance with FE 120 standards.

 

 

  • Screen Continuity Checks: Validates EMC shielding effectiveness.

 

 

8.2 System Integration Testing

 

 

 

  • Emergency Circuit Validation: Confirms operational integrity under fire conditions.

 

 

  • Performance Monitoring: Detects potential faults early.

 

 


 

Feichun SIENOPYR FR MHXCH FE 120 Fire-Resistant Marine Power Cables - Comprehensive Emergency System Application Guide 1

 

9. Maintenance and Inspection

 

 

9.1 Regular Maintenance

 

 

  • Visual inspections for mechanical damage.

 

  • Testing for insulation integrity.

 

  • Monitoring performance metrics.

 

9.2 Emergency Response Planning

 

 

  • Develop recovery protocols for damaged circuits.

 

  • Train personnel on emergency repair strategies.

 

 

 


10. Quality Assurance

 

 

 

 

10.1 Manufacturing Standards

 

 

Feature Benefit
Rigorous Testing Ensures product reliability.
Traceability Systems Facilitates easy certification.

 

 

 

 

10.2 Installation Quality

 

 

Adherence to classification society rules ensures safe and reliable cable installations.

 

 


 

 

11. Conclusion

 

 

 

The Feichun SIENOPYR FR MHXCH FE 120 cable is a highly reliable solution for fire-resistant power supply in marine and offshore environments. Its compliance with stringent standards ensures the safety and functionality of critical emergency systems during extreme conditions.

 

 

 

For inquiries or to learn more about how these cables can enhance your marine installations, contact Feichun Cable today!

 

 

 

 

 

 

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

 

 

 

 

 

 

 

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.