Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: VDE 0250 Part 813

Model Number: SIENOPYR FR M2XH 0.6/1kV Power Cable

Payment & Shipping Terms

Minimum Order Quantity: 200 Meter

Price: 10-30 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 18,000 meters per week

Highlight:
Temperature Rating:
-40°C To 90°C
Current Rating:
1000A
Standards:
NEC, NFPA 70
Tensile Strength:
5000 Lbs
Application:
Shipboard And Marine Environments
Reliable Transmission:
Ensures Consistent Power Transmission
High Conductivity Core:
Excellent Conductivity
Resistance:
Oil, Chemicals, Abrasion
Compact Design:
Space-efficient For Easy Handling
Impact Resistant:
Guards Against Impact Damage
Flame Retardant:
Yes
High Current Capability:
Efficient High-current Transmission
Temperature Rating:
-40°C To 90°C
Current Rating:
1000A
Standards:
NEC, NFPA 70
Tensile Strength:
5000 Lbs
Application:
Shipboard And Marine Environments
Reliable Transmission:
Ensures Consistent Power Transmission
High Conductivity Core:
Excellent Conductivity
Resistance:
Oil, Chemicals, Abrasion
Compact Design:
Space-efficient For Easy Handling
Impact Resistant:
Guards Against Impact Damage
Flame Retardant:
Yes
High Current Capability:
Efficient High-current Transmission
Feichun SIENOPYR FR M2XH 0.6/1kV Power Cables for Ships and Offshore Units: Comprehensive Application and Installation Guide

Feichun SIENOPYR FR M2XH 0.6/1kV Power Cables for Ships and Offshore Units: Comprehensive Application and Installation Guide

 

 

In the demanding environments of marine and offshore installations, reliable and high-performance cables are critical.

 

 

 

Feichun's SIENOPYR FR M2XH 0.6/1kV Power Cables are designed specifically to meet the unique challenges of fixed installations on ships and offshore units, ensuring durability, fire safety, and excellent electrical performance.

 

 

Feichun SIENOPYR FR M2XH 0.6/1kV Power Cables for Ships and Offshore Units: Comprehensive Application and Installation Guide 0

 

 

 

This guide will provide a detailed overview of these cables, including their key features, technical specifications, installation methods, and maintenance best practices.

 

 

 

 

Whether you're installing cables in the engine room, control spaces, or on the weather deck, this article will equip you with the knowledge you need for a successful application.

 

 

 


2. Technical Specifications

 

 

 

2.1 Construction Features

 

 

 

 

Feature Details
Conductor Material Plain, round stranded copper, compliant with IEC 60228 Class 2 or Class 5
Insulation Material Cross-linked polyethylene (XLPE)
Core Identification Follows HD 308 S2 standard
Outer Sheath Material Halogen-Free Flame Retardant (HFFR) compound

 

 

 

The use of XLPE insulation ensures excellent thermal and electrical performance, while the HFFR sheath provides flame retardancy and low smoke emissions, making the cable suitable for safety-critical installations.

 

 

 

 

2.2 Electrical Characteristics

 

 

Parameter Specification
Rated Voltage 0.6/1kV (Um: 1.2kV)
Test Voltage 3.5kV
Max. Conductor Temperature 90°C
Short Circuit Temperature 250°C

 

 

 

 

 

 

 

These electrical properties ensure stable power transmission and compliance with marine standards, even in high-demand scenarios.

 

 

 

 

2.3 Thermal Properties

 

 

 

 

Parameter Value
Maximum Operating Temperature 90°C
Short Circuit Temperature 250°C
Minimum Laying Temperature -15°C

 

 

 

 

 

 

The cable's ability to withstand high short-circuit temperatures ensures durability and reliability in the event of an electrical fault.

 

 

 

 


3. Standards and Compliance

 

 

3.1 Marine Standards

 

 

 

Feichun's SIENOPYR FR M2XH cables are designed to meet or exceed the following marine and offshore standards:

 

 

 

  • IEC 60092-353: Marine power cables

 

  • IEC 60092-360: Insulation materials

 

  • IEC 60092-201: System design

 

 

 

 

These standards ensure compatibility with shipboard systems and compliance with classification society requirements.

 

 

 

 

3.2 Safety Standards

 

 

Feature Standard
Flame Retardancy IEC 60332-1-2 / IEC 60332-3-22
Low Smoke Emission IEC 61034
Halogen-Free Properties IEC 60754-1/2
Oil and Ozone Resistance IEC 60811-404

 

 

 

 


 

4. Marine Installation Guidelines

 

 

4.1 Location-Specific Requirements

 

 

Location Key Considerations
Engine Room High-temperature tolerance and oil resistance
Accommodation Spaces Low smoke and halogen-free properties for safety
Weather Deck UV and salt spray resistance for outdoor durability
Junction Boxes Secure terminations and ingress protection

 

4.2 Installation Methods

 

 

Parameter Requirement
Bending Radius 6 × OD
Support and Securing Systems Proper clamps and supports
Penetration Sealing Fireproof and watertight seals
Termination Techniques Crimping and sealing as per standards

 

 

 


 

5. Environmental Protection Measures

 

 

 

5.1 Fire Safety Features

 

 

 

 

The HFFR outer sheath ensures superior flame retardancy and smoke suppression, reducing hazards during a fire. The cable complies with:

 

 

  • IEC 60332-1-2 (Flame retardancy of a single cable)

 

  • IEC 60332-3-22 (Flame retardancy in bundled cables)

 

 

 

5.2 Chemical Resistance

 

 

Parameter Property
Oil Resistance Compliant with IEC 60811-404
Ozone Resistance Yes
UV Resistance Ensures long-term durability outdoors
Salt Spray Protection Suitable for marine environments

 

 

 

 


Feichun SIENOPYR FR M2XH 0.6/1kV Power Cables for Ships and Offshore Units: Comprehensive Application and Installation Guide 1

 

 

6. Installation Challenges and Solutions

 

 

6.1 Common Issues

 

 

  • Space Constraints: Use compact routing and multi-layered configurations.

 

  • Mechanical Stress: Employ robust clamps and vibration dampeners.

 

  • Temperature Management: Ensure appropriate derating for high temperatures.

 

 

6.2 Best Practices

 

Challenge Solution
Cable Routing Use direct paths to minimize bends
Stress Relief Install proper strain relief at terminations
Mechanical Protection Install conduits in high-impact areas

 

 

 

 


7. Load Calculations and Sizing

 

 

7.1 Current Rating Factors

 

 

Factor Consideration
Temperature Derating Adjust for ambient conditions
Grouping Factors Avoid excessive heating from nearby cables
Voltage Drop Keep voltage loss within acceptable limits

 

 

 

 


8. Testing and Commissioning

 

 

8.1 Pre-Installation Testing

 

 

Test Purpose
Insulation Resistance Verify integrity of insulation
Continuity Checks Ensure proper conductor connections

 

 

 

 

8.2 Post-Installation Verification

 

 

Test Purpose
System Testing Validate electrical performance
Performance Verification Confirm compliance with specifications

 

 

 

 


9. Maintenance and Lifecycle Management

 

 

9.1 Preventive Maintenance

 

 

Regular inspection ensures continued performance and safety. Monitor for:

 

 

  • Physical damage

 

  • Changes in signal quality

 

  • Environmental wear and tear

 

 

 

9.2 Troubleshooting Guide

 

 

Issue Solution
Signal Degradation Check for damaged insulation
Physical Damage Replace compromised sections

 

 

 

 


10. Quality Assurance

 

 

Feichun cables undergo rigorous testing to ensure high standards of safety and performance, including:

 

 

  • Flame retardancy tests

 

  • Environmental resistance tests

 

  • Electrical property verification

 

 


11. Conclusion

 

 

The Feichun SIENOPYR FR M2XH 0.6/1kV Power Cable delivers exceptional performance and safety for marine and offshore applications. With its robust construction, adherence to international standards, and focus on fire safety, it is the ideal choice for demanding environments.

 

 

 

Whether you are designing a new system or upgrading existing installations, this cable ensures reliability and peace of mind.

 

 

 

Contact Feichun today to learn more about how our cables can meet your marine and offshore needs.

 

 

 

 

 

 

 

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

 

 

 

 

 

 

 

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.