Send Message
products
products
Home > products > Shipboard & Marine Cables > Feichun SIENOPYR FR PROFIBUS M-02Y(ST)CHX Marine Network Cable Comprehensive Installation and Application Guide

Feichun SIENOPYR FR PROFIBUS M-02Y(ST)CHX Marine Network Cable Comprehensive Installation and Application Guide

Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: VDE 0250 Part 813

Model Number: SIENOPYR FR PROFIBUS M-02Y(ST)CHX

Payment & Shipping Terms

Minimum Order Quantity: 800 Meter

Price: 10-50 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 18,000 meters per week

Highlight:
Halogen-Free:
Yes
Flexible Handling:
Easy Handling In Dynamic Conditions
Long Lifespan Assurance:
Extended Lifespan
Length:
Customizable
Waterproof Design:
Resistant To Water For Wet Environments
High Current Capability:
Efficient High-current Transmission
Flexibility:
Class 5 (IEC 60228)
Permissible Tensile Fore:
MAX 2250 N
Uv Resistant:
Yes
Easy Termination:
Simplifies The Termination Process
Standards:
IEC, IEEE, UL, CSA, NEK, BS, AS
Oil Resistance:
Yes
Connector Type:
NEMA L5-30P
Weather Resistance:
Resilient In Diverse Weather
Halogen-Free:
Yes
Flexible Handling:
Easy Handling In Dynamic Conditions
Long Lifespan Assurance:
Extended Lifespan
Length:
Customizable
Waterproof Design:
Resistant To Water For Wet Environments
High Current Capability:
Efficient High-current Transmission
Flexibility:
Class 5 (IEC 60228)
Permissible Tensile Fore:
MAX 2250 N
Uv Resistant:
Yes
Easy Termination:
Simplifies The Termination Process
Standards:
IEC, IEEE, UL, CSA, NEK, BS, AS
Oil Resistance:
Yes
Connector Type:
NEMA L5-30P
Weather Resistance:
Resilient In Diverse Weather
Feichun SIENOPYR FR PROFIBUS M-02Y(ST)CHX Marine Network Cable Comprehensive Installation and Application Guide

Feichun SIENOPYR FR PROFIBUS M-02Y(ST)CHX Marine Network Cable Comprehensive Installation and Application Guide

 

 

 

 

The Feichun SIENOPYR FR PROFIBUS M-02Y(ST)CHX is a specialised marine network cable designed for fixed installations on ships and offshore units.

 

 

 

This high-performance cable excels in harsh maritime environments, ensuring robust and reliable communication for critical systems.

 

 

Feichun SIENOPYR FR PROFIBUS M-02Y(ST)CHX Marine Network Cable Comprehensive Installation and Application Guide 0

 

 

 

Whether deployed below deck, on open decks, or in control rooms, this cable is engineered to handle the rigours of maritime and offshore operations.

 

 

 

 

Key Features:

 

  • Low Smoke Zero Halogen (LSZH) material for enhanced fire safety.

 

  • High resistance to oil, ozone, and salt spray, ensuring durability in marine environments.

 

  • Compliance with IEC 61784, IEC 61158, and IEC 60092-360 standards, meeting stringent maritime requirements.

 

  • Suitable for fixed installations but not recommended for continuous use in water.

 

 

Applications:

 

  • Network communication in control rooms, engine rooms, and open decks.

 

  • Integration into PROFIBUS DP and other fieldbus systems.

 

  • Use in environments with high electromagnetic interference (EMI).

 

 

 


2. Technical Specifications and Standards

 

 

2.1 Construction Features

 

 

Component Material Properties
Conductor Plain, round stranded copper Excellent conductivity and flexibility.
Core Insulation Foam-skin PE Superior electrical properties.
Screen Braiding, tinned copper Enhanced EMI protection.
Inner Sheath LSZH material Fire safety and low toxicity.
Outer Sheath Crosslinked polymer Resistant to oils, ozone, and harsh environments.

 

2.2 Electrical Characteristics

 

 

Parameter Value
Nominal Voltage (U0/U) 100/100V
Test Voltage 1kV
Conductor Temperature Max: 80°C
Laying Temperature Min: -15°C

 

 

 

 

2.3 Standards Compliance

 

 

The cable complies with critical maritime standards:

 

 

  • IEC 61784: Industrial communication networks.

 

  • IEC 61158: Fieldbus specifications.

 

  • IEC 60092-360: Marine cable construction requirements.

 

  • DIN EN 60332-3-24: Flame retardant standards.

 

 

 


3. Marine Installation Guidelines

 

 

3.1 Installation Environment Classifications

 

 

  • Below Deck: Protected from weather but prone to high temperatures.

 

  • Weather Deck: Requires UV resistance and durability against salt spray.

 

  • Engine Rooms: Must handle high EMI and temperatures.

 

  • Control Rooms: Precision in network communication is critical.

 

 

3.2 Installation Methods

 

Bending Radius Single Bend Multiple Bends
10 × OD Yes -
20 × OD - Yes

 

 

 

 

  • Support Methods: Secure using approved clamps and supports.

 

  • Penetration Sealing: Ensure water-tight seals at bulkheads.

 

 

 


Feichun SIENOPYR FR PROFIBUS M-02Y(ST)CHX Marine Network Cable Comprehensive Installation and Application Guide 1

 

4. Network Design Considerations

 

4.1 PROFIBUS Network Architecture

 

 

  • Segment Length: Ensure compliance with PROFIBUS specifications for maximum lengths.

 

  • Termination: Use appropriate terminators at the end of each segment.

 

  • Topology: Implement daisy-chain or star topologies based on the application.

 

 

 

4.2 EMC and Grounding

 

 

Key Consideration Recommendation
Screen Termination Use low-resistance grounding.
EMC Glands Ensure proper shielding.
Cross-Talk Prevention Maintain adequate cable spacing.

 

 

 

 

 

 


5. Environmental Protection

 

 

5.1 Fire Safety Features

 

 

 

Property Compliance Standard
Flame Retardant EN/IEC 60332-1-2, 60332-3-24
Low Smoke IEC/EN 61034-2
Halogen-Free IEC/EN 60754-1/2

 

 

 

 

5.2 Chemical Resistance

 

 

Resistance Property Compliance
Oil IEC/EN 60811-404
Ozone Yes
Salt Spray Ensures durability

 

 

 

 


Feichun SIENOPYR FR PROFIBUS M-02Y(ST)CHX Marine Network Cable Comprehensive Installation and Application Guide 2

6. Installation Challenges and Solutions

 

 

6.1 Common Installation Issues

 

 

  • Water Exposure: Use water-tight seals and junction boxes.

 

  • Mechanical Protection: Install protective conduits in high-risk areas.

 

  • Temperature Fluctuations: Ensure appropriate laying and operation temperature compliance.

 

 

6.2 Installation Best Practices

 

  • Cable Routing: Avoid sharp bends and high EMI areas.

 

  • Testing Procedures: Perform signal quality and insulation resistance tests.

 

 


7. Commissioning and Testing

 

 

7.1 Pre-installation Testing

 

 

  • Verify cable integrity and insulation resistance.

 

  • Document results for compliance verification.

 

 

7.2 Post-installation Testing

 

 

  • Test network communication and signal quality.

 

  • Validate system performance through integration testing.

 

 

 


8. Maintenance and Troubleshooting

 

 

8.1 Preventive Maintenance

 

 

  • Schedule regular inspections for physical condition and signal quality.

 

  • Monitor performance using diagnostic tools.

 

 

8.2 Common Faults and Solutions

 

  • Signal Degradation: Check for EMI sources or poor terminations.

 

  • Physical Damage: Replace damaged segments immediately.

 

 


Feichun SIENOPYR FR PROFIBUS M-02Y(ST)CHX Marine Network Cable Comprehensive Installation and Application Guide 3

 

9. Safety and Regulatory Compliance

 

 

9.1 Classification Society Requirements

 

 

  • Ensure compliance with type approval documentation from maritime bodies.

 

 

9.2 Documentation Requirements

 

  • Maintain installation records, test certificates, and maintenance logs.

 

 


10. Appendices

 

A. Installation Checklists

 

 

  • Pre-installation: Inspect cables, verify lengths, and confirm standards compliance.

 

  • Testing Sequence: Validate electrical and signal integrity.

 

 

B. Technical Data Tables

 

Parameter Value
Voltage Rating 100/100V
Test Voltage 1kV
Max Conductor Temp 80°C
Laying Temp (Min) -15°C

 

 

 


Conclusion

 

 

The Feichun SIENOPYR FR PROFIBUS M-02Y(ST)CHX marine cable is a robust solution for maritime and offshore communication systems. Its fire safety, chemical resistance, and compliance with PROFIBUS and maritime standards ensure reliable performance in demanding environments.

 

 

 

By following proper installation guidelines and regular maintenance, you can maximise the lifespan and efficiency of this cable, making it a valuable asset for any marine or offshore application.

 

 

 

 

Feichun Cable is committed to providing innovative solutions for your marine networking needs. Contact us today for customised recommendations!

 

 

 

 

 

 

 

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

 

 

 

 

 

 

 

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.