Send Message
products
products
Home > products > Shipboard & Marine Cables > Technical Guide to Feichun LMGSGO VG95218T61 Light Marine Screened Cables For Specifications, Installation, and Applications in Maritime Environments

Technical Guide to Feichun LMGSGO VG95218T61 Light Marine Screened Cables For Specifications, Installation, and Applications in Maritime Environments

Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: VDE 0250 Part 813

Model Number: LMGSGO VG95218T61 Light Marine Screened Cable

Payment & Shipping Terms

Minimum Order Quantity: 200 Meter

Price: 10-30 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 12,000 meters per week

Highlight:
Water Resistance:
Yes
Operating Temperature:
-40°C To 90°C
Chemical Resistance:
Chemically Resilient
Current Rating:
1000A
Optimized Bending Radius:
Flexible Curvature Design
Easy Installation Process:
Easy To Install
Reliable Transmission:
Ensures Consistent Power Transmission
Low Maintenance Need:
Low Maintenance Requirement
Jacket Material:
Rubber
Insulation Material:
XLPE Or EPR
Outstanding Flexibility:
Extremely Flexible
Waterproof:
Yes
Impact Resistant:
Guards Against Impact Damage
Compact Design:
Space-efficient For Easy Handling
Water Resistance:
Yes
Operating Temperature:
-40°C To 90°C
Chemical Resistance:
Chemically Resilient
Current Rating:
1000A
Optimized Bending Radius:
Flexible Curvature Design
Easy Installation Process:
Easy To Install
Reliable Transmission:
Ensures Consistent Power Transmission
Low Maintenance Need:
Low Maintenance Requirement
Jacket Material:
Rubber
Insulation Material:
XLPE Or EPR
Outstanding Flexibility:
Extremely Flexible
Waterproof:
Yes
Impact Resistant:
Guards Against Impact Damage
Compact Design:
Space-efficient For Easy Handling
Technical Guide to Feichun LMGSGO VG95218T61 Light Marine Screened Cables For Specifications, Installation, and Applications in Maritime Environments

Technical Guide to Feichun LMGSGO VG95218T61 Light Marine Screened Cables

Specifications, Installation, and Applications in Maritime Environments

 

 

 

The Feichun LMGSGO VG95218T61 Halogen-free Light Marine Screened Cables are a premium solution for fixed installations on ships, both below deck and on open decks.

 

 

 

 

Technical Guide to Feichun LMGSGO VG95218T61 Light Marine Screened Cables For Specifications, Installation, and Applications in Maritime Environments 0

 

 

Designed for environments where space, weight, and safety are critical, these cables deliver high performance and compliance with stringent maritime standards.

 

 

 

 

 

Key features include:

 

 

  • Light power applications, specifically tailored for marine settings.

 

  • Exceptional electromagnetic compatibility (EMC) through robust screening.

 

  • Durability against harsh marine environments, including seawater exposure and vibration.

 

  • Halogen-free, low-smoke properties, ensuring safety in enclosed spaces.

 

 

These cables are ideal for light power distribution, control systems, and instrumentation in maritime environments.

 

 

 

1.2 Standards and Compliance

 

 

Feichun LMGSGO VG95218T61 cables comply with:

 

 

  • VG 95218-61: A standard specifically for light marine power cables.

 

  • BV 3400 Installation Requirements: Ensuring safe deployment in diverse ship locations.

 

  • IEC Standards: Including IEC/EN 60332-1-2 for flame retardancy and IEC/EN 60754-1/2 for halogen-free properties.

 

  • Approval from leading classification societies for maritime use.

 

 

Technical Guide to Feichun LMGSGO VG95218T61 Light Marine Screened Cables For Specifications, Installation, and Applications in Maritime Environments 1

 

 


2. Technical Construction

 

 

2.1 Cable Design

 

 

These cables are engineered to meet the demands of marine installations with:

 

 

 

Component Specification
Conductor Plain, round stranded copper (VG 95218 part 61).
Insulation Cross-linked Low Smoke Zero Halogen (LS0H).
Screen Construction Bare copper braiding for EMC shielding.
Outer Sheath Cross-linked polymer for durability.

 

 

 

 

The combination of materials ensures resistance to fire, chemicals, and mechanical stresses.

 

 

2.2 EMC Protection System

 

 

Electromagnetic compatibility (EMC) is a critical feature for maritime applications where signal interference can disrupt operations.

 

 

 

Feature Benefit
Copper Braided Screen High coverage for EMI/RFI shielding.
Grounding Requirements Ensures safety and signal integrity.
Continuous Shield Bonding Prevents interruptions in critical systems.

 

 

 

 


3. Performance Parameters

 

 

3.1 Electrical Characteristics

 

 

Parameter Value
Voltage Rating (U0/U) 300/500 V
Test Voltage 2.5 kV
Max Conductor Temperature 90°C
Short Circuit Temperature 250°C

 

 

 

 

The cables are designed for stable electrical performance under varying conditions, supporting long-term reliability.

 

 

3.2 Environmental Performance

 

 

Parameter Value
Operating Temperature -15°C to +90°C
Laying Temperature Minimum -15°C
Chemical Resistance Oil, ozone, and seawater.

 

 

 

 

These features ensure resilience against extreme marine environments, including temperature fluctuations and corrosive elements.

 

 


4. Safety Features

 

 

4.1 Fire Performance

 

 

The halogen-free, low-smoke design is critical for fire safety on ships.

 

 

 

Standard Description
IEC/EN 60332-1-2 Flame retardant.
IEC/EN 61034-2 Low smoke emission.
IEC/EN 60754-1/2 Halogen-free, reducing toxicity.

 

 

 

 

4.2 Chemical Resistance

 

 

Feature Benefit
Oil Resistance Withstands marine oils.
Seawater Resistance Prevents corrosion and degradation.
Ozone Resistance Ensures durability in humid conditions.

 

 

 

 


5. Installation Guidelines

 

 

5.1 Mechanical Requirements

 

 

Specification Requirement
Bending Radius 5 × outer diameter (OD).
Tensile Strength Max. 50 N/mm².

 

 

 

 

5.2 EMC Installation Practices

 

 

Step Description
Screen Termination Secure grounding to prevent interference.
EMC Gland Selection Use glands for complete shielding.
Continuous Shield Bonding Maintains uninterrupted protection.

 

 

 

 


6. Maritime Applications

 

 

6.1 Installation Locations

 

 

Area Considerations
Open Decks UV and saltwater resistance.
Engine Rooms High-temperature tolerance.
Below Deck Fire and moisture resistance.

 

 

 

6.2 System Integration

 

 

The cables seamlessly integrate into:

 

 

  • Light power distribution networks.

 

  • Control systems and instrumentation.

 

  • Emergency lighting circuits.

 

 


7. Common Installation Challenges

 

 

7.1 EMC-Related Issues

 

 

Maintaining EMC continuity is crucial. Solutions include:

 

 

  • Ensuring proper grounding of screens.

 

  • Using EMC-certified glands and connectors.

 

 

7.2 Environmental Considerations

 

 

Preventing environmental damage requires:

 

 

  • Adequate sealing against moisture ingress.

 

  • Using corrosion-resistant supports and fasteners.

 

 

 


Technical Guide to Feichun LMGSGO VG95218T61 Light Marine Screened Cables For Specifications, Installation, and Applications in Maritime Environments 2

8. Quality Assurance

 

 

8.1 Factory Testing

 

 

Test Objective
Voltage Withstand Testing Verify electrical integrity.
Material Property Validation Ensure compliance with VG 95218.

 

 

 

 

8.2 Installation Testing

 

 

Test Purpose
EMC Effectiveness Testing Confirm shielding performance.
Insulation Resistance Measurement Ensure safety and reliability.

 

 

 

 


9. Maintenance and Troubleshooting

 

 

9.1 Preventive Maintenance

 

 

Routine checks ensure long-term performance:

 

 

  • Visual inspection for wear or damage.

 

  • Testing screen continuity to avoid interference.

 

 

9.2 Problem Resolution

 

 

Common issues like conductor fatigue or EMC failure can be resolved through proper diagnostics and timely repairs.

 

 

 


10. Technical Reference

 

 

10.1 Compliance Documentation

 

 

  • VG 95218-61: Core specifications.

 

  • IEC Standards: Safety and performance benchmarks.

 

 

10.2 Installation Reference

 

 

  • Cable selection criteria for specific maritime applications.

 

  • Correction factors to account for environmental variables.

 

 


Conclusion

 

Feichun LMGSGO VG95218T61 cables combine lightweight design, robust performance, and superior safety for marine applications. With compliance to VG 95218-61 and industry-leading materials, these cables ensure reliable operations in the most challenging environments.

 

 

By choosing Feichun, you benefit from decades of expertise and a commitment to innovation in marine cable solutions. Contact us today to explore how these cables can enhance your maritime systems!

 

 

 

 

 

 

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

 

 

 

 

 

 

 

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.