Send Message
products
products
Home > products > Shipboard & Marine Cables > Technical Guide to Feichun MGSGO VG95218T60 Screened Marine Power Cables: EMC, Installation, and Maritime Applications

Technical Guide to Feichun MGSGO VG95218T60 Screened Marine Power Cables: EMC, Installation, and Maritime Applications

Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: VDE 0250 Part 813

Model Number: MGSGO VG95218T60 Screened Marine Power Cable

Payment & Shipping Terms

Minimum Order Quantity: 200 Meter

Price: 10-50 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 12,000 meters per week

Highlight:
Features:
Flexible, Oil And Sunlight Resistant
Swift Power Transfer:
Rapid Power Distribution
Optimized Bending Radius:
Flexible Curvature Design
Sturdy Connector Design:
Solid Connector Construction
Weather Resistance:
Resilient In Diverse Weather
Impact Resistant:
Guards Against Impact Damage
Compact Installation:
Compact Design
Uv Stability:
UV Stable Structure
Versatile Compatibility:
Fits Various Equipment Configurations
Connector Type:
NEMA L5-30P
Underground Ready:
Suited For Underground Mining
Application:
Power And Control Wiring For Shipboard And Marine Environments
Safety Certifications:
Certified For Safety
Water Resistance:
IEC 60502-1, IEC 60228
Features:
Flexible, Oil And Sunlight Resistant
Swift Power Transfer:
Rapid Power Distribution
Optimized Bending Radius:
Flexible Curvature Design
Sturdy Connector Design:
Solid Connector Construction
Weather Resistance:
Resilient In Diverse Weather
Impact Resistant:
Guards Against Impact Damage
Compact Installation:
Compact Design
Uv Stability:
UV Stable Structure
Versatile Compatibility:
Fits Various Equipment Configurations
Connector Type:
NEMA L5-30P
Underground Ready:
Suited For Underground Mining
Application:
Power And Control Wiring For Shipboard And Marine Environments
Safety Certifications:
Certified For Safety
Water Resistance:
IEC 60502-1, IEC 60228
Technical Guide to Feichun MGSGO VG95218T60 Screened Marine Power Cables: EMC, Installation, and Maritime Applications

Technical Guide to Feichun MGSGO VG95218T60 Screened Marine Power Cables: EMC, Installation, and Maritime Applications

 

 

 

The Feichun MGSGO VG95218T60 Screened Marine Power Cable is specifically engineered for marine environments. It combines superior electrical performance with robust materials to meet the demanding conditions of maritime operations.

 

 

 

Technical Guide to Feichun MGSGO VG95218T60 Screened Marine Power Cables: EMC, Installation, and Maritime Applications 0

 

 

Designed according to VG 95218 part 60, this cable is halogen-free, flame retardant, and offers exceptional EMC shielding to minimise electromagnetic interference in sensitive shipboard systems.

 

 

 

 

Key Features:

 

 

  • Halogen-free cross-linked LS0H insulation for enhanced safety.

 

  • A durable copper braided screen to ensure consistent shielding performance.

 

  • Outer sheath made of cross-linked polymer for protection against harsh environmental conditions.

 

  • Suitable for fixed installations in all shipboard locations, including open decks.

 

 

Applications:

 

  • Power distribution systems

 

  • EMC-sensitive control circuits

 

  • Emergency power circuits

 

  • Marine equipment interfaces

 

 


1.2 Standards and Certifications

 

 

The Feichun MGSGO VG95218T60 meets or exceeds international and maritime-specific standards:

 

 

Standard/Requirement Description
VG 95218-60 Governs design and performance for marine cables.
BV 3400 Installation requirements for ships and open decks.
EN/IEC 60332-1-2 Flame retardant compliance.
IEC/EN 60754-1/2 Halogen-free performance.
IEC/EN 60811-404 Resistance to oil and other chemicals.

 

2. Technical Construction

 

 

2.1 Core Construction

 

 

The core of the MGSGO VG95218T60 is engineered for high performance and durability:

 

 

 

Component Specification
Conductor Plain, round stranded copper, VG 95218-60 compliant.
Insulation Cross-linked LS0H material for fire safety and durability.
Screen Construction Braided copper for effective EMC shielding.
Outer Sheath Cross-linked polymer for robust environmental protection.

 

2.2 EMC Screening System

 

 

Electromagnetic compatibility (EMC) is a critical factor in modern marine systems. The copper braided screen in this cable offers:

 

 

  • Effective EMI/RFI protection: Ensures signal integrity even in high-interference environments.

 

  • High coverage screening: Minimises electrical noise in power and control circuits.

 

  • Easy grounding: Facilitates secure termination and grounding practices.

 

 


3. Performance Specifications

 

 

3.1 Electrical Parameters

 

 

Parameter Value
Rated Voltage (U0/U) 0.6/1 kV
Test Voltage 3.5 kV
Max Conductor Temp (Normal) 90°C
Max Conductor Temp (Short) 250°C

 

 

 

 


3.2 Environmental Performance

 

 

Parameter Value
Operating Temp Range -15°C to +90°C
Flame Retardancy EN/IEC 60332-1-2 compliant.
Halogen-Free IEC/EN 60754-1/2 compliant.
Chemical Resistance Oil, ozone, seawater, and chemical-resistant.

 

 

 


4. Safety Features

 

 

4.1 Fire Safety

 

 

The MGSGO VG95218T60 is built with fire-resistant materials to ensure safety during emergencies:

 

 

  • Low smoke emission minimises visibility impairment.

 

  • Halogen-free properties reduce toxic gas release.

 

  • Certified for marine fire performance, crucial for safety compliance.

 

 


4.2 Chemical Resistance

 

 

With its cross-linked polymer sheath, this cable provides:

 

 

  • Resistance to oil and chemicals.

 

  • Robust performance against ozone and UV exposure.

 

  • Excellent seawater resistance, ensuring durability in maritime environments.

 

 


5. Installation Guidelines

 

 

5.1 General Installation Requirements

 

 

Parameter Specification
Bending Radius 5× OD (4× OD for F-types).
Tensile Strength Limit 50 N/mm².
Screen Termination Requires grounding for EMC integrity.

 

 

 

 


5.2 EMC-Specific Installation

 

 

To maximise the EMC performance, adhere to the following:

 

 

  • Use EMC-compliant glands to maintain continuity.

 

  • Ensure screen bonding across cable runs.

 

  • Follow cross-bonding techniques where applicable.

 

 


6. Maritime Application Considerations

 

6.1 Location-Specific Requirements

 

 

This cable is versatile for various shipboard locations:

 

 

  • Engine Rooms: High-temperature and vibration resistance.

 

  • Open Decks: UV and seawater resistance for exposed environments.

 

  • Below Decks: Flame retardant and halogen-free for confined spaces.

 

 


6.2 System Integration

 

 

The MGSGO VG95218T60 integrates seamlessly into:

 

 

  • Power distribution systems.

 

  • EMC-sensitive equipment, ensuring signal integrity.

 

  • Emergency power systems for critical operations.

 

 

 


Technical Guide to Feichun MGSGO VG95218T60 Screened Marine Power Cables: EMC, Installation, and Maritime Applications 1

7. Common Installation Challenges

 

 

7.1 EMC-Related Issues

 

 

  • Ensure screen continuity throughout the cable run.

 

  • Avoid sharp bends that can damage the screen integrity.

 

 

7.2 Environmental Challenges

 

  • Protect against corrosion and moisture.

 

  • Consider vibration-resistant supports in high-movement areas.

 

 

 


8. Testing and Verification

 

8.1 Factory Testing

 

 

Test Purpose
Voltage Withstand Test Ensures insulation reliability.
Screen Continuity Test Verifies EMC integrity.

 

 

 

 


8.2 Installation Testing

 

  • Perform EMC effectiveness testing post-installation.

 

  • Conduct polarity and insulation resistance checks.

 

 


9. Maintenance Procedures

 

9.1 Routine Maintenance

 

 

  • Regularly inspect for physical damage and corrosion.

 

  • Test screen continuity and overall electrical performance.

 

 


9.2 Problem Resolution

 

  • Replace cables showing significant wear or compromised EMC performance.

 

 


10. Technical Reference

 

10.1 Standard Compliance

 

 

Fully compliant with VG 95218, IEC/EN 60332, and other critical marine standards.

 

 

 

10.2 Technical Data

 

 

Specification Detail
Conductor Size Range Various (customisable to application).
Screen Coverage High-density copper braid.

 

 

 

 


Conclusion

 

The Feichun MGSGO VG95218T60 Screened Marine Power Cable delivers unparalleled performance for marine environments, combining robust EMC shielding with fire-resistant and environmentally resilient materials.

 

 

By adhering to the outlined installation guidelines and leveraging its advanced design, this cable ensures reliable, safe, and efficient operations across diverse shipboard applications.

 

 

For expert advice and customised solutions, contact Feichun Cable today.

 

 

 

 

 

 

 

 

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

 

 

 

 

 

 

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.