Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: VDE 0250 Part 813

Model Number: MGGO VG95218T60 Marine Power Cable

Payment & Shipping Terms

Minimum Order Quantity: 200 Meter

Price: 10-30 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 12,000 meters per week

Highlight:
Model:
Corrosion-Proof Marine Cable
Maximum Ampacity:
170 Amps
Voltage Rating:
600V
Operating Temperature:
-40°C To +90°C
Water Resistant:
Yes
Optimized For Quarrying:
Designed For Quarrying Applications
Cable Type:
Flexible
Tensile Strength:
5000 Lbs
Compact Design:
Space-efficient For Easy Handling
Underground Ready:
Suited For Underground Mining
Certifications:
UL, CSA, ABS, DNV, BV, LR, NK, RINA, RS
Shielded:
Yes
Standards:
IEEE 1580, IEEE 45, IEC 60092-350, IEC 60092-353
High Current Capability:
Efficient High-current Transmission
Model:
Corrosion-Proof Marine Cable
Maximum Ampacity:
170 Amps
Voltage Rating:
600V
Operating Temperature:
-40°C To +90°C
Water Resistant:
Yes
Optimized For Quarrying:
Designed For Quarrying Applications
Cable Type:
Flexible
Tensile Strength:
5000 Lbs
Compact Design:
Space-efficient For Easy Handling
Underground Ready:
Suited For Underground Mining
Certifications:
UL, CSA, ABS, DNV, BV, LR, NK, RINA, RS
Shielded:
Yes
Standards:
IEEE 1580, IEEE 45, IEC 60092-350, IEC 60092-353
High Current Capability:
Efficient High-current Transmission
Comprehensive Guide to Feichun MGGO VG95218T60 Marine Power Cables: Technical Specifications, Installation Requirements, and Maritime Applications

Comprehensive Guide to Feichun MGGO VG95218T60 Marine Power Cables: Technical Specifications, Installation Requirements, and Maritime Applications

 

 

Feichun’s MGGO VG95218T60 marine power cables are specifically engineered for demanding maritime applications. Designed for fixed installation on ships, these cables ensure reliable power transmission in diverse environments, including below deck, on open decks, and engine rooms.

 

Comprehensive Guide to Feichun MGGO VG95218T60 Marine Power Cables: Technical Specifications, Installation Requirements, and Maritime Applications 0

 

 

 

 

They meet the VG 95218-60 specifications, making them ideal for maritime and offshore power systems.

 

 

 

 

With their halogen-free composition, low-smoke emissions, and exceptional resistance to harsh environments, these cables are indispensable for safe and efficient marine operations.

 

 

 


1.2 Maritime Standards and Certifications

 

 

The MGGO VG95218T60 series complies with numerous international maritime standards, ensuring reliability and safety:

 

 

 

Standard Description
VG 95218-60 Defines requirements for marine-grade cables.
EN/IEC 60332-1-2 Flame retardancy for enhanced safety.
IEC/EN 60754-1/2 Halogen-free compliance for low corrosive effects during combustion.
IEC/EN 61034-2 Guarantees low smoke emissions for better visibility in fire scenarios.
BV 3400 Installation Outlines specifications for cable installations in maritime environments.

 

 

 


2. Technical Specifications

 

 

2.1 Cable Construction

 

 

The MGGO VG95218T60 cables are crafted with precision to meet the demands of the marine industry. Their construction prioritizes durability, flexibility, and safety.

 

 

 

Component Material/Specification
Conductor Plain, round stranded copper (VG 95218 part 60).
Core Insulation Cross-linked LSOH (low-smoke, halogen-free).
Outer Sheath Cross-linked polymer for maximum environmental resistance.
Core Identification Marked for easy installation and system integration.

 

2.2 Performance Parameters

 

 

Parameter Specification
Voltage Rating 0.6/1 kV.
Test Voltage 3.5 kV.
Temperature Range - Normal operation: 90°C.
  - Short circuit: 250°C.
  - Installation: -15°C minimum.

 

 

 

 


3. Safety and Environmental Features

 

 

3.1 Fire Safety Characteristics

 

 

Safety is paramount in marine environments. Feichun’s MGGO VG95218T60 cables offer excellent fire resistance, ensuring operational reliability in emergencies.

 

 

  • Flame Retardancy: Certified under EN/IEC 60332-1-2 to prevent flame spread.

 

  • Low Smoke: Emits minimal smoke for better visibility during fires (IEC/EN 61034-2).

 

  • Halogen-Free: Complies with IEC/EN 60754-1/2, reducing corrosive gases during combustion.

 

 


3.2 Environmental Resistance

 

 

Designed to endure the harshest maritime conditions, these cables are:

 

 

 

Resistance Feature Specification
Oil Resistance Certified under IEC/EN 60811-404.
Ozone and UV Resistance Provides extended durability in exposed conditions.
Seawater Resistance Withstands corrosion from saltwater exposure.

 

 

 


4. Marine Installation Guidelines

 

 

4.1 Installation Requirements

 

 

To ensure optimal performance, follow these guidelines:

 

 

 

Parameter Specification
Bending Radius - 5 × OD for standard types.
  - 4 × OD for F-types.
Tensile Strength Permanent load capacity of 50 N/mm².
Temperature Limits Ensure the installation temperature is above -15°C.

 

 

 

 


4.2 Location-Specific Installation

 

 

Different ship locations present unique challenges. The MGGO VG95218T60 cables are versatile enough for all these applications:

 

 

 

Location Key Considerations
Open Decks UV and weather-resistant sheath ensures long-term reliability.
Engine Rooms High-temperature tolerance of 90°C ensures operational stability.
Below Decks Flame retardancy enhances safety in confined spaces.
Bulkhead Passages Maintain watertight integrity with proper sealing methods.

 

 

 

Comprehensive Guide to Feichun MGGO VG95218T60 Marine Power Cables: Technical Specifications, Installation Requirements, and Maritime Applications 1

 

 

 


5. Maritime Application Considerations

 

 

5.1 Shipboard Systems Integration

 

 

These cables are vital for various shipboard systems:

 

 

  • Power Distribution: Reliable energy transmission to critical systems.

 

  • Emergency Power: Ensures backup systems remain operational.

 

  • Control Systems: Seamless integration into marine automation networks.

 

 


5.2 Environmental Factors

 

 

Challenge Solution Provided by MGGO VG95218T60
Salt Spray Seawater-resistant sheath prevents corrosion.
Humidity LSOH insulation ensures consistent performance.
Temperature Variations Wide operational range from -15°C to 90°C.
Vibration Flexible stranded copper minimizes mechanical stress.

 

 

 


6. Common Installation Challenges

 

 

6.1 Physical Installation Issues

 

 

Challenge Recommended Solution
Space Constraints Use cables with smaller OD for tight spaces.
Watertight Penetrations Ensure proper sealing with marine-rated glands.
Bend Radius Compliance Follow specified bending radii to avoid damage.

 

 

 


6.2 Environmental Challenges

 

 

Challenge Solution Provided by MGGO VG95218T60
Corrosion Cross-linked polymer sheath resists aggressive chemicals.
Moisture Halogen-free materials ensure insulation integrity.
Temperature Extremes Operates in extreme conditions without degradation.

 

 

 


7. Quality Assurance and Testing

 

 

7.1 Factory Testing

 

 

Every cable undergoes rigorous testing:

 

 

Test Purpose
Voltage Testing Verifies insulation strength (3.5 kV).
Material Property Testing Ensures compliance with international standards.

 

 

 


7.2 Installation Testing

 

 

After installation, ensure cables are tested for:

 

 

Test Purpose
Continuity Testing Confirms proper conductor connections.
Insulation Resistance Validates safety under operational voltages.

 

 

 

 


8. Maintenance and Inspection

 

 

Routine Maintenance Task Recommended Frequency
Visual Inspection Quarterly or before major voyages.
Electrical Testing Annually or during major overhauls.
Documentation Update Post-installation and maintenance activities.

 

 

 


9. Regulatory Compliance

 

 

  • Classification Society Approvals: Meets BV, DNV, and Lloyd’s standards.

 

 

  • Documentation: Maintain installation certificates, test reports, and maintenance records for regulatory audits.

 

 


10. Call to Action

 

 

Feichun’s MGGO VG95218T60 marine power cables are a proven solution for reliable and safe maritime operations. Their durability, environmental resistance, and compliance with international standards make them a preferred choice for shipbuilders and operators.

 

 

Contact Feichun today for customized solutions tailored to your specific maritime needs. Our team offers expert guidance to ensure you select the most suitable cable for your application.

 

 

 

 

 

 

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

 

 

 

 

 

 

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.