Send Message
products
products
Home > products > DIN VDE 0118-10 Mining Cable > Feichun MV Single Core Cables SIENOPYR (120) (N)HXSGAFHXOE 3.6/6KV Halogen-Free Single Core Cables Having Special Fire Performance

Feichun MV Single Core Cables SIENOPYR (120) (N)HXSGAFHXOE 3.6/6KV Halogen-Free Single Core Cables Having Special Fire Performance

Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™ Mining

Certification: VDE 0250 Part 813

Model Number: SIENOPYR(120) (N)HXSGAFHXOE 3.6/6KV

Payment & Shipping Terms

Minimum Order Quantity: 800 Meter

Price: 10-30 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 16,000 meters per week

Highlight:
Flexible:
Yes
Trademark:
LINKE
Uv Resistance:
Yes
Application:
Underground Mining
Standard:
DIN VDE 0118-10
Feature:
High Sound Quality
Jacket:
Rubber
Bending Radius:
8 X Cable Diameter
Flame Retardant:
Yes
Durable Construction:
Long-lasting In Demanding Conditions
Easy Installation:
Flexible Installation
Compact Design:
Space-efficient Construction.
Outer Sheath Color:
Black
Voltage:
1.8/3kV
Flexible:
Yes
Trademark:
LINKE
Uv Resistance:
Yes
Application:
Underground Mining
Standard:
DIN VDE 0118-10
Feature:
High Sound Quality
Jacket:
Rubber
Bending Radius:
8 X Cable Diameter
Flame Retardant:
Yes
Durable Construction:
Long-lasting In Demanding Conditions
Easy Installation:
Flexible Installation
Compact Design:
Space-efficient Construction.
Outer Sheath Color:
Black
Voltage:
1.8/3kV
Feichun MV Single Core Cables SIENOPYR (120) (N)HXSGAFHXOE 3.6/6KV Halogen-Free Single Core Cables Having Special Fire Performance

Feichun MV Single Core Cables: SIENOPYR(120) (N)HXSGAFHXOE 3.6/6KV Halogen-Free Cables with Special Fire Performance

 

 

 

Mining operations require robust, reliable, and efficient cables to meet the demanding challenges of the industry.

 

 

 

The Feichun MV Single Core Cables SIENOPYR(120), featuring halogen-free construction and exceptional fire performance, are designed to excel in fixed wiring and limited-flex environments in mining applications.

 

 

 

Feichun MV Single Core Cables SIENOPYR (120) (N)HXSGAFHXOE 3.6/6KV Halogen-Free Single Core Cables Having Special Fire Performance 0

 

 

With advanced materials and compliance with international standards, these cables ensure safety, efficiency, and longevity in harsh mining conditions.

 

 

 

 

These cables stand out with their low smoke, halogen-free properties, making them suitable for environments where fire safety and reduced toxic emissions are crucial.

 

 

 

Their application as fixed wiring in heavy-duty mining equipment or environments ensures durability and performance under mechanical and electrical stress.

 

 

 


Technical Specifications and Compliance

 

 

Core Standards

 

 

Feichun MV Single Core Cables adhere to the following key standards:

 

 

Standard Description
IEC 60228 Defines conductors of insulated cables.
DIN VDE 0250-602 Covers requirements for mining cables.
EN/IEC 60332-1-2 Flame retardancy standard.
IEC/EN 61034-2 Low smoke emission certification.

 

 

 

 

The cables undergo rigorous testing to ensure they meet international quality and safety requirements, providing peace of mind to operators.

 

 

 

Construction Specifications

 

 

Parameter Details
Conductor Class 5 tinned copper, finely stranded.
Insulation Cross-linked LS0H material for enhanced safety.
Outer Sheath EVA rubber for durability and resistance.
Available Sizes 1x95, 1x120, 1x240 (RD/YE/BK).

 

 

 

 


Electrical Parameters

 

 

Parameter Details
Rated Voltage 3.6/6 (7.2) kV.
Test Voltage 11 kV.
Max Conductor Temperature 120°C during operation.
Short Circuit Temperature 250°C.

 

 

 

 

These cables exhibit excellent current-carrying capacity and minimal voltage drop, ensuring optimal energy efficiency in long installations.

 

 


Performance Characteristics

 

 

Temperature Ratings

 

 

Condition Value
Maximum conductor temp. 120°C.
Short circuit temp. limit 250°C.
Minimum laying temp. -40°C.

 

 

 

The wide temperature range ensures reliable performance in extreme environments.

 

 

Fire Performance

 

 

Feichun SIENOPYR(120) cables comply with stringent fire safety standards, including:

 

 

  • EN/IEC 60332-1-2: Ensures flame retardance.

 

  • EN/IEC 60332-3-24: Verifies cable resistance to spread of fire.

 

  • IEC/EN 61034-2: Confirms low smoke emission in fire scenarios.

 

 


Feichun MV Single Core Cables SIENOPYR (120) (N)HXSGAFHXOE 3.6/6KV Halogen-Free Single Core Cables Having Special Fire Performance 1

 

 

Installation Guidelines

 

 

Mechanical Parameters

 

 

Parameter Value
Bending Radius (Fixed) 4x OD (≤12mm), 5x OD (>12mm).
Bending Radius (Moving) 5x OD (≤12mm), 6x OD (>12mm).
Permanent Tensile Strength 15 N/mm².

 

 

 

Installation Best Practices

 

  • Ensure proper pulling techniques to avoid mechanical stress.

 

  • Maintain the recommended bending radius to prevent conductor damage.

 

  • Install within the temperature range of -40°C to 120°C for optimal performance.

 

 


Common Challenges and Solutions

 

 

Installation Challenges

 

 

Challenge Solution
Confined spaces Adhere to bending radius guidelines.
Extreme temperatures Monitor and adjust for environmental factors.
Proper termination Use certified connectors and methods.

 

 

 

 

Operational Issues

 

 

Issue Mitigation
Thermal management Install ventilation systems.
Vibration effects Use vibration-resistant fittings.
Environmental stress cracking Regular inspections and maintenance.

 

 

 

 


Application-Specific Considerations

 

 

Mining Applications

 

 

Designed for demanding mining environments, these cables resist chemical exposure, mechanical stress, and thermal variations, ensuring long-term reliability.

 

 

Selection Criteria

 

 

Factor Details
Load requirements Match cable size with operational current.
Installation methods Consider fixed vs. free-moving installations.
Environmental conditions Evaluate temperature and chemical exposure risks.

 

 

 


 

 

Feichun MV Single Core Cables SIENOPYR (120) (N)HXSGAFHXOE 3.6/6KV Halogen-Free Single Core Cables Having Special Fire Performance 2

 

Maintenance and Troubleshooting

 

 

 

Preventive Maintenance

 

 

 

Task Frequency
Visual inspections Monthly.
Electrical testing Annually or as needed.
Documentation updates After each inspection or repair.

 

 

 

 

 

 

Common Faults and Remedies

 

 

 

Fault Remedy
Insulation degradation Replace damaged sections.
Mechanical damage Use protective coverings.

 

 

 

 

 


 

Comparative Analysis

 

 

Size Selection Guide

 

 

Size Current Rating Fire Load (MJ/km) Weight (kg/km)
1x95 250 A 5800 1150
1x120 300 A 6700 1420
1x240 500 A 11000 2690

 

 

 


Safety and Environmental Considerations

 

 

These cables contribute to a safer mining environment with their halogen-free and low smoke characteristics. Their materials and construction minimize environmental impact while providing top-notch performance.

 

 


Conclusion

 

 

The Feichun MV Single Core SIENOPYR(120) Cables are a reliable and safe choice for modern mining applications. With superior materials, adherence to international standards, and exceptional fire performance, they meet the demanding needs of the mining industry.

 

 

 

 

When installed and maintained correctly, they offer long-term efficiency, safety, and durability.

 

 

 

For more information and assistance, feel free to contact Feichun Cable experts.

 

 

 

 

 

 

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

 

 

 

 

 

 

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.