Product Details
Place of Origin: Hefei Anhui China
Brand Name: FeiChun™ Mining
Certification: VDE 0250 Part 813
Model Number: EPN 78
Payment & Shipping Terms
Minimum Order Quantity: 800 Meter
Price: 10-50 USD per meter, price varies according to specifications
Packaging Details: Cable Reels or Packaging Bags
Delivery Time: 15-30 Work Day
Payment Terms: T/T, Western Union
Supply Ability: 16,000 meters per week
Flexible Handling: |
Easy Handling In Dynamic Conditions |
Current Rating: |
1000A |
Shielding Material: |
Tinned Copper |
Tailored For Handling: |
Enhances Material Handling Efficiency |
Abrasion Resistance: |
High |
Conductor Material: |
Copper |
Shielding Coverage: |
100% |
Underground Ready: |
Suited For Underground Mining |
Abrasion Resistant: |
Yes |
Oil Resistance: |
Yes |
Easy Installation: |
Flexible Installation |
Flexible: |
Yes |
Standard: |
IEC 60502, AS/NZS 2802, BS 6346 |
Tensile Strength: |
30kN |
Flexible Handling: |
Easy Handling In Dynamic Conditions |
Current Rating: |
1000A |
Shielding Material: |
Tinned Copper |
Tailored For Handling: |
Enhances Material Handling Efficiency |
Abrasion Resistance: |
High |
Conductor Material: |
Copper |
Shielding Coverage: |
100% |
Underground Ready: |
Suited For Underground Mining |
Abrasion Resistant: |
Yes |
Oil Resistance: |
Yes |
Easy Installation: |
Flexible Installation |
Flexible: |
Yes |
Standard: |
IEC 60502, AS/NZS 2802, BS 6346 |
Tensile Strength: |
30kN |
The Feichun EPN 78 3.6/6 kV Flexible Medium Voltage Reeling Cable is a cutting-edge power solution for heavy-duty industrial machinery.
Engineered with precision, it delivers superior performance under harsh operational conditions, making it a top choice for industries such as mining, construction, and material handling.
This cable combines advanced insulation technology, mechanical resilience, and environmental durability to ensure uninterrupted power supply, even in the most demanding environments.
With its compliance to DIN VDE, IEC, and other international standards, the Feichun EPN 78 sets a benchmark in reliability, safety, and operational efficiency.
Open-cast mining equipment: Excavators, loaders, and dumpers.
Material handling machinery: Mobile crushers and loading bridges.
Reeling drum systems: Used in large-scale industrial operations requiring constant movement.
Solves issues related to mechanical wear, electrical stress, and environmental exposure.
Employs state-of-the-art insulation materials for enhanced safety and longevity.
Offers unmatched flexibility and high mechanical durability, reducing downtime and maintenance costs.
The Feichun EPN 78’s electrical design ensures efficient power transmission while maintaining safety under high loads.
Electrical Parameter | Specification |
---|---|
Rated Voltage | 3.6/6 (7.2) kV |
Nominal Voltage | 6000 V |
Test Voltage | AC 15 kV |
Maximum Conductor Temperature | 90°C |
Short Circuit Temperature Tolerance | 250°C for 5 seconds |
Key Benefits:
High Voltage Capacity: Supports medium-voltage applications, ensuring optimal performance for large-scale industrial equipment.
Heat Resistance: Withstands elevated temperatures during normal and short-circuit conditions, safeguarding operations.
Feature | Detail |
Conductor Material | High-purity stranded copper |
Conductor Design | Finely stranded, Class 5 |
Tinned Copper | Provides corrosion resistance |
Structural Enhancements | Optimized for flexibility |
Why It Matters:
The finely stranded copper conductor ensures superior conductivity and flexibility, making it ideal for reeling applications.
Tinned copper enhances durability by resisting corrosion in challenging environments like mines and construction sites.
The Feichun EPN 78 cable employs advanced EPR (Ethylene Propylene Rubber) and semi-conductive layers to ensure safety and performance.
Layer | Material |
Inner Semi-Conducting Layer | Semi-conductive EPR |
Core Insulation | EPR Rubber Compound 3GI3 |
Outer Semi-Conducting Layer | Semi-conductive NBR (easy-strip) |
Advantages:
The semi-conductive EPR layer evenly distributes electrical stress, preventing insulation failure.
The NBR outer layer facilitates quick and safe stripping during installation and repairs.
Feature | Material |
Core Design | Three-core |
Inner Sheath | EPR Rubber Compound 5GM3 |
Outer Sheath | Chlorinated Polyethylene (CPE) |
Key Features:
The three-core design with integrated protective earth conductors ensures operational safety and reliability.
The CPE outer sheath provides excellent resistance to UV rays, ozone, and abrasion.
Parameter | Fixed Installation | Flexible Installation |
Temperature Range | -40°C to +80°C | -25°C to +60°C |
Benefits:
Suitable for extreme climates, from freezing conditions to high-heat environments.
Provides reliable performance across various operational setups.
Feature | Detail |
Flame Retardant | Complies with EN 60332-1-2 |
Oil Resistance | High |
UV Resistance | Excellent |
Ozone Resistance | Outstanding |
Value Proposition:
The cable’s resistance to flame, oil, and ozone ensures safety and longevity in harsh industrial environments.
Parameter | Specification |
Tensile Strength | 15 N/mm² |
Minimum Bending Radius | 10 x Outer Diameter |
Flexibility | High |
Advantages:
Handles mechanical stresses such as pulling and flexing with ease.
The flexible design supports continuous movement, ideal for reeling systems.
Standard | Specification |
DIN VDE 0250-813 | Yes |
SRPS N.C5.374 | Yes |
IEC 60228 | Yes |
EN 60332-1-2 | Yes |
What This Means:
Assured safety, quality, and compatibility across global industrial standards.
Meets stringent regulatory requirements for medium voltage cables.
Application | Machinery |
Mining | Excavators, dumpers |
Material Handling | Mobile crushers, loading bridges |
Industrial Operations | Open-cast mining equipment |
Why It Works:
Designed to endure the high stresses of mining and material handling operations, reducing downtime and enhancing efficiency.
Bending Radius Compliance: Ensure a bending radius of at least 10x the outer diameter.
Proper Handling: Avoid crushing or overstretching the cable during installation.
Environment Assessment: Account for temperature, UV exposure, and chemical contact.
Electrical Stress: Overloads or surges can damage insulation.
Mechanical Wear: Reeling operations can cause wear and tear.
Environmental Degradation: Prolonged exposure to UV, oil, or chemicals.
Maintenance Task | Frequency |
Visual Inspection | Monthly |
Electrical Testing | Biannually |
Insulation Integrity Check | Annually |
Tips:
Regular inspections and testing can prevent unexpected failures.
Use specialized tools to monitor performance metrics like insulation resistance.
The Feichun EPN 78 3.6/6 kV stands out due to:
Advanced insulation materials that ensure longevity.
Comprehensive environmental resistance unmatched by competitors.
Exceptional mechanical flexibility, ideal for reeling systems.
Best Practices: Adhere to bending radius and environmental guidelines.
Installation Advice: Consult qualified professionals for site-specific requirements.
Maintenance Plan: Implement regular performance checks to maximize lifespan.
Emerging trends in cable technology, such as nanomaterial-based insulation and smart cable monitoring systems, will continue to enhance the efficiency and durability of industrial cables like the Feichun EPN 78.
Stay ahead by integrating innovative solutions into your operational framework.
The Feichun EPN 78 3.6/6 kV Flexible Medium Voltage Reeling Cable is a high-performance solution for industries requiring robust, reliable, and durable cables.
With its advanced features, compliance to international standards, and unparalleled environmental resistance, this cable is an investment in operational excellence.
For more information or to request a consultation, contact our technical support team today.
VDE_German_Standard_Feichun_Mining_Cable.pdf
United_States_&_Canada_Standards_Feichun_Mining_Cable.pdf
Australia_&_New_Zealand_Standards_Feichun_Mining_Cable.pdf
Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.