Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: VDE 0250 Part 813

Model Number: EPN 63

Payment & Shipping Terms

Minimum Order Quantity: 800 M

Price: 8-10 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 16,000 meters per week

Highlight:
Conductor Size:
1.5mm² - 240mm²
Conductor Material:
Copper
Reliable Transmission:
Ensures Consistent Power Transmission
Shielding Material:
Tinned Copper
Flexibility:
Flexible
Transport Package:
Accept Negotiate
Oil Resistant:
Yes
Standards:
VDE 0250 Part 813 And Part 814
Flame Retardant:
Yes
Armor Material:
Galvanized Steel
Number Of Cores:
3
Feature:
High Sound Quality
Conductor Size:
1.5mm² - 240mm²
Conductor Material:
Copper
Reliable Transmission:
Ensures Consistent Power Transmission
Shielding Material:
Tinned Copper
Flexibility:
Flexible
Transport Package:
Accept Negotiate
Oil Resistant:
Yes
Standards:
VDE 0250 Part 813 And Part 814
Flame Retardant:
Yes
Armor Material:
Galvanized Steel
Number Of Cores:
3
Feature:
High Sound Quality
FeiChun EPN 63: Advanced Rubber-Sheathed Flexible Cable for Underground Mining Applications

FeiChun EPN 63: Advanced Rubber-Sheathed Flexible Cable for Underground Mining Applications

 

 

 

 

The FeiChun EPN 63 rubber-sheathed flexible cable is designed for mobile equipment and machines operating in the harsh and demanding environments of underground mining.

 

 

 

 

FeiChun EPN 63: Advanced Rubber-Sheathed Flexible Cable for Underground Mining Applications 0

 

 

Primarily used as a power supply connection cable for coal cutting machines and other mobile mining equipment, this cable ensures uninterrupted power transmission under extreme operational conditions.

 

 

 

With its superior durability, flexibility, and reliability, the FeiChun EPN 63 cable is engineered to withstand the challenges posed by underground mining environments, ensuring continuous operation and reducing the risk of electrical failure.

 

 

 

 

In this article, we will explore the key features, technical specifications, and applications of the FeiChun EPN 63 cable, while providing valuable insights to ensure optimal installation, maintenance, and usage.

 

 


Key Technical Specifications

 

 

The FeiChun EPN 63 cable is designed for demanding underground mining operations where reliability, flexibility, and safety are paramount. Here are the key specifications:

 

 

Electrical Characteristics

 

Feature Specification
Rated Voltage U0/U (Um) 0.6/1 (1.2) kV
Nominal Voltage 1,000 V
Primary Test Voltage 3 kV
Control Cores Test Voltage 2 kV AC

 

 

 

 

These ratings ensure the cable can withstand electrical stresses and provide reliable power transmission in underground mining applications.

 

 

 

Conductor and Insulation Design

 

 

Feature Specification
Conductor Material Finely stranded tinned copper (Class 5)
Conductor Configuration Three main conductors, two control cores, one monitoring conductor
Protective Earth Overall concentric braid of tinned copper wires
Core Insulation EPR rubber – Special Compound 3GI3
Outer Semi-Conducting Layer Confirmed
Screen Material Tinned copper braided screen

 

 

 

The cable's finely stranded copper conductors ensure high electrical conductivity and flexibility, making it suitable for mobile equipment.

 

 

 

 

The protective earth and semi-conducting layer further enhance safety by providing grounding and protection against electrical faults.

 

 

 

Sheath Specifications

 

 

 

Feature Specification
Inner Sheath Rubber – Special Compound 5GM3
Outer Sheath Chlorinated Polyethylene (CM/CPE) – Special Compound 5GM5

 

 

 

The multi-layered sheath provides enhanced protection against external physical stress, such as abrasion, and shields the cable from chemical and environmental damage.

 

 

 

Performance Specifications

 

 

Performance Attribute Specification
Maximum Conductor Temperature 90°C
Short Circuit Peak Temperature 250°C
Operating Temperature Range (Fixed Installation) -40°C to +80°C
Operating Temperature Range (Flexible Installation) -25°C to +60°C
Flame Retardancy Full compliance with EN/IEC 60332-1-2
Chemical Resistance Oil, Ozone, UV, and Sea Water Resistant
Permanent Tensile Strength 15 N/mm²
Bending Radius Fixed Installation: 4 × Cable Diameter
Flexible Operation 5 × Cable Diameter

 

 

 

These specifications ensure that the FeiChun EPN 63 cable can endure a wide range of temperatures, environmental hazards, and mechanical stresses, making it ideal for underground mining operations.

 

 

 


Critical Challenges in Underground Mining Cable Applications

 

 

Underground mining operations pose unique challenges to power supply cables, including constant mechanical stress, extreme environmental conditions, and the need for consistent electrical performance.

 

 

 

The FeiChun EPN 63 cable is specifically designed to tackle these challenges and provide reliable, long-lasting performance.

 

 

1. Mechanical Stress Management

 

 

Underground mining machinery is subject to extreme mechanical stress due to constant movement, tension, and abrasive environments. The cables used in these operations must be durable and capable of handling:

 

 

  • Constant movement and tension from mobile mining equipment

 

  • Abrasion caused by rocks, dust, and debris

 

  • Unpredictable directional changes as machinery moves through the mine

 

 

 

FeiChun Solution:

 

 

The FeiChun EPN 63 cable is designed with a multi-layered conductor and protective braiding to withstand these mechanical stresses.

 

 

 

The high tensile strength (15 N/mm²) ensures that the cable maintains its integrity during operation, even when subjected to heavy strain.

 

 

2. Environmental Extremes

 

 

Underground mining environments expose cables to harsh conditions:

 

 

  • Temperature fluctuations, from freezing conditions to intense heat

 

  • Chemical exposures such as oils and other mining substances

 

  • Mechanical wear and tear from the abrasive nature of mining operations

 

 

FeiChun Solution:

 

 

The FeiChun EPN 63 cable offers a wide operating temperature range (-40°C to +80°C for fixed installation and -25°C to +60°C for flexible installation).

 

 

 

It is also resistant to oils, ozone, UV, and even sea water, ensuring the cable remains functional in extreme conditions.

 

 

 

3. Electrical Integrity and Safety

 

 

Maintaining stable electrical performance is crucial in underground mining, where disruptions can lead to equipment failure, safety risks, and downtime. Power cables must provide:

 

 

  • Stable power transmission with minimal interference

 

  • Protection against short circuits

 

  • Grounding for added safety

 

 

 

FeiChun EPN 63: Advanced Rubber-Sheathed Flexible Cable for Underground Mining Applications 1FeiChun Solution:

 

 

The FeiChun EPN 63 cable features precisely engineered insulation and a concentric protective-earth design, ensuring that electrical performance remains stable while providing enhanced safety features.

 

 


 

Recommended Deployment Guidelines

 

 

To ensure the optimal performance of the FeiChun EPN 63 cable, follow these installation and maintenance guidelines:

 

 

1. Pre-Installation Inspection

 

 

  • Inspect the cable for any visible damage or defects before installation.
  • Verify that the cable's bending radius is suitable for the installation environment to avoid damage during operation.

 

 

2. Bending Radius Compliance

 

 

  • During installation, maintain the specified bending radius as per the manufacturer’s instructions (4 × cable diameter for fixed installations, 5 × cable diameter for flexible installations) to prevent internal conductor damage.

 

 

3. Regular Maintenance

 

 

  • Visual Inspection: Check cables regularly for signs of wear and tear or damage.

 

 

  • Electrical Testing: Perform periodic electrical performance testing to ensure the cable continues to meet operational requirements.

 

 

 

4. Cable Replacement

 

 

  • Replace cables showing signs of damage, including visible cuts, tears, or insulation degradation, to avoid operational downtime or safety hazards.

 

 


Monitoring and Maintenance Checklist

 

 

Frequency Task
Quarterly Visual inspection for physical damage, wear, or external abrasions
Bi-Annually Electrical performance testing (continuity, insulation, voltage)
As Needed Immediate replacement of cables showing structural damage or performance issues

 

 

 

Regular maintenance and monitoring are crucial to ensure the cable remains in optimal condition throughout its service life.

 

 

 


Specialized Applications

 

 

The FeiChun EPN 63 cable is ideally suited for the following underground mining applications:

 

 

 

  • Coal cutting machines

 

  • Mobile underground mining equipment

 

  • Continuous mining systems

 

  • Heavy-duty mining operations in extreme environments

 

 

 

This cable is designed to provide reliable power supply for a wide range of mobile mining equipment, ensuring that your machines operate at maximum efficiency and safety.

 

 


FeiChun EPN 63: Advanced Rubber-Sheathed Flexible Cable for Underground Mining Applications 2

 

Conclusion

 

 

The FeiChun EPN 63 rubber-sheathed flexible cable represents the cutting edge of cable technology for underground mining applications. With its advanced construction, superior materials, and high-performance specifications, it offers unmatched reliability and safety in the most demanding underground environments.

 

 

 

 

The FeiChun EPN 63 cable is the ideal solution for coal cutting machines and other mobile mining equipment, providing long-lasting performance and reducing the risk of operational downtime.

 

 

 

 

By choosing the FeiChun EPN 63, you are ensuring that your underground operations benefit from consistent power transmission, enhanced safety, and reliable performance in even the most challenging conditions.

 

 

For specialized application consulting, technical support, or custom configuration requirements, contact the FeiChun engineering team today.

 

 


 

 

Disclaimer: Always consult local mining regulations and specific equipment manufacturer guidelines when selecting and installing power supply cables to ensure compliance with safety standards.