Send Message
products
products
Home > products > DIN VDE 0118-10 Mining Cable > Feichun PROTOMONT (N)TSKCGECWOEU 1.9/3.3KV: Advanced Coal Cutter Cables for Extreme Mining Environments

Feichun PROTOMONT (N)TSKCGECWOEU 1.9/3.3KV: Advanced Coal Cutter Cables for Extreme Mining Environments

Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™ Mining

Certification: VDE 0250 Part 813

Model Number: (N)TSKCGECWOEU

Payment & Shipping Terms

Minimum Order Quantity: 800 Meter

Price: 10-30 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 18,000 meters per week

Highlight:
Features:
Oil And Abrasion Resistant
Shielding Material:
Tinned Copper
Color:
Black
Water Resistant:
Yes
Voltage Rating:
0.6/1 KV
Number Of Cores:
3
Sheath Material:
PCP
Flame Retardant:
Yes
Filler:
Optional
Warranty:
1 Year
Conductor:
Tinned Copper
Standards:
VDE 0118-10
Temperature Range:
-25°C To +60°C
Jacket Material:
PUR
Features:
Oil And Abrasion Resistant
Shielding Material:
Tinned Copper
Color:
Black
Water Resistant:
Yes
Voltage Rating:
0.6/1 KV
Number Of Cores:
3
Sheath Material:
PCP
Flame Retardant:
Yes
Filler:
Optional
Warranty:
1 Year
Conductor:
Tinned Copper
Standards:
VDE 0118-10
Temperature Range:
-25°C To +60°C
Jacket Material:
PUR
Feichun PROTOMONT (N)TSKCGECWOEU 1.9/3.3KV: Advanced Coal Cutter Cables for Extreme Mining Environments

Feichun PROTOMONT (N)TSKCGECWOEU 1.9/3.3KV: Advanced Coal Cutter Cables for Extreme Mining Environments

 

 

The Feichun PROTOMONT (N)TSKCGECWOEU cable is the next-generation solution tailored for the toughest underground mining environments.

 

 

Designed to meet the rigorous demands of mobile equipment like coal cutting machines, this cable excels in environments where conventional options fail.

 

 

 

Feichun PROTOMONT (N)TSKCGECWOEU 1.9/3.3KV: Advanced Coal Cutter Cables for Extreme Mining Environments 0

 

 

Specifically engineered for use in cable protection chains (or cable handlers) trailing behind mobile machinery, these cables are built to absorb the stresses of mining operations while maintaining top-notch performance.

 

 


Technical Specifications and Engineering Excellence

 

 

Electrical Characteristics

 

 

Specification Details
Rated Voltage U0/U (Um) 1.9/3.3 (4.0) kV
Nominal Voltage 3,300 V
Primary Test Voltage 11 kV
Control Cores Test Voltage 2 kV AC

 

 

 

 

Conductor and Insulation Architecture

 

 

 

 

Feature Details
Conductor Material Very finely stranded tinned copper
Core Configuration Three main cores + concentric control/PE conductor elements
Core Insulation EPR Rubber (PROTOLON Compound 3GI3)
Outer Semi-Conducting Layer Semi-conductive NBR, easy-strip technology
Inner Sheath Special EPR Compound GM1b
Outer Sheath Polychloroprene (PCP) PROTOFIRM

 

 

Performance Envelope

 

 

Parameter Range/Limit
Max Conductor Temperature 90°C
Short Circuit Temperature 250°C
Operating Temp (Fixed) -40°C to +80°C
Operating Temp (Flexible) -20°C to +60°C
Torsional Stress Tolerance ±25°/m
Tensile Strength 15 N/mm²
Bending Radius (Standard) 2.3 × Cable Diameter
Bending Radius (Directional) 20 × Cable Diameter

 

 

 

 

Environmental Resistance

 

 

Feature Compliance/Details
Flame Retardancy EN/IEC 60332-1-2 compliant
Oil Resistance Fully resistant
Ozone Resistance Excellent
UV Protection Enhanced

 

 

 

 

 


Comprehensive Standards Compliance

 

 

The Feichun PROTOMONT cable series meets and exceeds the following international standards:

 

 

 

  • EN/IEC 60332-1-2 for flame retardancy

  • DIN VDE 0250-813

  • DIN EN 60228 / IEC 60228 / VDE 0295 for conductor specifications

  • MSHA P-07-KA140034 for mining safety

  • GOST Fire Certificate of the Russian Federation

 

 

 

These certifications underline its reliability and safety in the most challenging operational environments.

 

 

 


Critical Challenges in Underground Mining Cable Applications

 

 

1. Mechanical Stress Management

 

 

Problem: Mining cables endure constant movement, tension, and exposure to abrasive materials.

 

 

Feichun Solution:

 

 

  • Robust, finely stranded Class FS copper conductors ensure flexibility.

  • High tensile strength (15 N/mm²) provides resilience under strain.

  • Optimized for use in cable handlers trailing behind mobile equipment.

 

 

2. Temperature and Environmental Extremes

 

 

Problem: Underground mines experience severe temperature fluctuations and exposure to chemicals.

 

 

Feichun Solution:

 

 

  • Operating temperature range of -40°C to +80°C for fixed installations.

  • Multi-layer protective compounds resist oil, ozone, and UV degradation.

 

 

3. Electrical Integrity and Safety

 

 

Problem: Maintaining high-voltage stability and electrical performance in demanding conditions.

 

 

 

Feichun Solution:

 

  • Precision-engineered insulation for enhanced dielectric strength.

  • Double concentric control/PE conductors for reliable grounding.

  • Tested to withstand up to 11 kV.

 

 

 


Feichun PROTOMONT (N)TSKCGECWOEU 1.9/3.3KV: Advanced Coal Cutter Cables for Extreme Mining Environments 1

 

Installation and Maintenance Guidelines

 

 

Pre-Installation

 

 

  • Conduct thorough visual and electrical inspections of the cable.

  • Verify compatibility with the mining environment and equipment specifications.

 

 

During Installation

 

 

Task Best Practice
Bending Radius Maintain a radius of at least 2.3 × diameter
Tensile Loads Avoid exceeding 15 N/mm²
Cable Handling Use specialized equipment to minimize stress
Directional Changes Ensure a bending radius of 20 × diameter for sharp turns

 

 

Post-Installation

 

 

  • Regularly inspect for wear and tear, especially in high-stress areas.

  • Perform electrical tests annually to ensure consistent performance.

  • Replace cables showing signs of insulation damage or excessive wear.

 

 

 

 


Monitoring and Maintenance Checklist

 

 

Inspection Task Frequency
Visual Integrity Assessment Quarterly
Electrical Performance Testing Annually
Insulation Wear Monitoring Ongoing
Environmental Exposure Logging Post-installation

 

 

 

 


Specialized Applications

 

 

The Feichun PROTOMONT (N)TSKCGECWOEU is ideal for:

 

 

  • Coal Cutting Machines: Provides stable, high-voltage power supply under dynamic conditions.

  • Mobile Mining Equipment: Designed to endure continuous movement and tension.

  • Cable Chains (Cable Handlers): Absorbs tensile forces while maintaining structural integrity.

 

 

 


Feichun PROTOMONT (N)TSKCGECWOEU 1.9/3.3KV: Advanced Coal Cutter Cables for Extreme Mining Environments 2

 

Why Choose Feichun PROTOMONT?

 

 

1. Unmatched Reliability

 

 

Engineered with multi-layer protection, these cables withstand the mechanical, electrical, and environmental stresses unique to underground mining.

 

 

 

2. Advanced Materials

 

 

The use of EPR Rubber and PCP Special Compounds ensures durability and resistance to oil, UV, and extreme temperatures.

 

 

 

3. Comprehensive Customization

 

 

Available in multiple configurations to meet specific operational needs.

 

 

 

4. Proven Safety Standards

 

 

Certified to exceed international mining and electrical safety requirements, ensuring peace of mind for operators.

 

 

 


Conclusion

 

 

The Feichun PROTOMONT (N)TSKCGECWOEU cable sets a new benchmark for underground mining cables. By addressing critical challenges like mechanical stress, environmental resilience, and electrical integrity, it ensures maximum operational reliability and safety.

 

 

 

Whether you’re powering coal cutting machines or operating mobile mining equipment, this cable delivers unmatched performance.

 

 

Professional Support

 

 

For tailored solutions, technical consultations, or custom configurations, contact the Feichun Engineering Team today.

 

 

Let us help you select the best cable for your needs and ensure a seamless installation process.

 

 

Disclaimer: Always adhere to local mining regulations and manufacturer recommendations when selecting and installing specialized cables.