Send Message
products
products
Home > products > DIN VDE 0118-10 Mining Cable > Anti-Static Mining Cable for Explosive Coal Environment - ATEX Compliant , Static Discharge Protected , Enhanced Safety

Anti-Static Mining Cable for Explosive Coal Environment - ATEX Compliant , Static Discharge Protected , Enhanced Safety

Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™ Mining

Certification: ATEX Compliant

Model Number: Anti-Static Mining Cable for Explosive Coal Environment

Payment & Shipping Terms

Minimum Order Quantity: 800 Meter

Price: 10-60 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 18,000 meters per week

Highlight:

ATEX Compliant Mining Cable

,

Static Discharge Protected Mining Cable

,

Enhanced Safety Mining Cable

Water Resistant:
Yes
Uv Resistant:
Yes
Standards:
VDE 0250 Part 813 And Part 814
Feature:
High Sound Quality
Conductor Material:
Copper
Rated:
8kV
Oil Resistant:
Yes
Jacket Material:
PUR Cable
Armor Type:
No Armor
Application:
Mining Industry
Armor Material:
Galvanized Steel
Shielding:
Unshielded
Water Resistant:
Yes
Uv Resistant:
Yes
Standards:
VDE 0250 Part 813 And Part 814
Feature:
High Sound Quality
Conductor Material:
Copper
Rated:
8kV
Oil Resistant:
Yes
Jacket Material:
PUR Cable
Armor Type:
No Armor
Application:
Mining Industry
Armor Material:
Galvanized Steel
Shielding:
Unshielded
Anti-Static Mining Cable for Explosive Coal Environment - ATEX Compliant , Static Discharge Protected , Enhanced Safety

Anti-Static Mining Cable for Explosive Coal Environment - ATEX Compliant, Static Discharge Protected, Enhanced Safety

 

When working in coal mines or other explosive environments, safety is paramount. One of the most critical aspects of ensuring a safe and reliable operation is using the proper cables that can resist the risks associated with static discharge, flammable gases, and high temperatures.

 

 

 

Anti-Static Mining Cable for Explosive Coal Environment - ATEX Compliant , Static Discharge Protected , Enhanced Safety 0

 

 

Our Anti-Static Mining Cable for explosive coal environments is specifically designed to meet these needs, offering enhanced safety and compliance with the stringent ATEX standards.

 

 

 

 

This article will provide you with the detailed knowledge you need about this specialized ATEX-compliant mining cable, its installation requirements, usage, and why it’s the best solution for your operations. Let’s dive into the essential aspects of these cables and how they ensure maximum protection in hazardous environments.

 

 


 

What is ATEX Compliance?

 

 

 

ATEX (Atmosphères Explosibles) refers to a set of European Union directives designed to ensure safety in environments where explosive atmospheres may exist. This includes industries like mining, oil and gas, and chemical processing.

 

 

 

ATEX-compliant cables are essential for preventing the ignition of flammable substances by eliminating static discharge and providing robust insulation.

 

 

 

Key Features of Anti-Static Mining Cable for Explosive Coal Environments

 

 

 

Our Anti-Static Mining Cable is engineered with several key features to enhance safety in hazardous environments, particularly those with high levels of coal dust and explosive gases.

 

 

Static Discharge Protection: Static electricity is a serious risk in coal mines, where the presence of flammable gases and dust can create dangerous conditions. Our cables are equipped with specialized static discharge protection, ensuring that they won’t accumulate static electricity, thus preventing the risk of sparks and explosions.

 

 

 

 

 

 

ATEX Compliance: Our cables are fully ATEX-compliant, which means they meet all the necessary safety standards required for operation in explosive atmospheres. This certification ensures that the cable is safe for use in areas where the presence of explosive gases or dust is a concern.

 

 

 

 

 

 

High Durability and Flexibility: Mining operations often demand cables that can endure extreme mechanical stress and harsh environmental conditions. Our anti-static mining cable is designed to withstand constant bending, abrasion, and exposure to chemical substances, providing reliable performance even under tough working conditions.

 

 

 

 

 

 

Enhanced Fire Resistance: In mining environments, where high temperatures and the risk of fire are constant concerns, our cables are built to be fire-resistant. They are designed to continue functioning in high-heat environments without catching fire or emitting toxic gases.

 

 

 

 

 

 

Oil, Abrasion, and UV Resistance: The cable’s outer jacket is engineered to withstand oil, abrasion, and UV radiation, ensuring long-lasting performance in challenging conditions.

 

 

How Does Anti-Static Mining Cable Enhance Safety?

 

 

 

Mining operations, especially in explosive coal environments, require a comprehensive safety plan. The use of anti-static mining cables plays a critical role in this plan. Let’s explore how this cable improves safety at every level:

 

 

Prevents Static Discharge: In environments with volatile gases like methane, static discharge can cause sparks, leading to explosions. Our anti-static cables are specifically designed to minimize this risk by safely dissipating any static buildup.

 

 

 

 

 

 

 

Reduces Fire Hazards: In coal mines, dust accumulation and equipment friction can easily lead to sparks. Our cables have built-in fire resistance, ensuring that they won’t contribute to any potential ignition sources.

 

 

 

 

 

 

 

Improves Operational Continuity: With durable construction and high flexibility, these cables can handle constant movement, reducing downtime caused by cable failures, while ensuring continuous, safe operation.

 

 

Installation and Use of Anti-Static Mining Cables

 

 

Proper installation and maintenance are key to ensuring the cable performs effectively in explosive environments. Here are some important considerations for installation and use:

 

 

 

1. Pre-Installation Checks

 

 

Before installing the anti-static mining cable, ensure that you are using the right cable for the application. The cable should be properly rated for the voltage, current, and environmental conditions it will be exposed to.

 

 

 

Check for the ATEX compliance marking to ensure it meets the required standards for explosive atmospheres.

 

 

 

 

 

 

 

 

 

2. Correct Routing

 

 

 

Cables should be routed in a way that minimizes the risk of damage. Avoid running cables through areas with excessive wear or mechanical stress.

 

 

 

 

Use cable trays, supports, and other management systems to ensure the cables are protected from abrasion and external mechanical damage.

 

 

 

 

 

 

 

 

 

3. Grounding and Bonding

 

 

 

Proper grounding is critical to reducing the risk of static buildup. Ensure the anti-static mining cables are properly grounded at both ends and any intermediate points. This will help safely dissipate any potential static charge that may accumulate during operation.

 

 

 

 

 

 

4. Regular Inspections

 

 

 

Routine inspections should be carried out to check for any signs of wear, damage, or degradation. Look for any visible signs of cracking, fraying, or exposure of the inner conductors, which could compromise the safety and performance of the cable.

 

 

 

 

 

 

5. Cable Maintenance

 

 

 

Ensure that the anti-static mining cable is regularly maintained to prolong its life. Clean the cables periodically, remove any debris or dust that could cause damage, and ensure the jacket remains intact to protect the internal components.

 

 

 

 

 

 

6. Avoiding Overloading

 

 

 

Overloading the cable can cause overheating and damage to the insulation, potentially leading to electrical faults. Always use the cable according to the manufacturer's specifications, and avoid exceeding its rated current and voltage.

 

 

 


 

 

Benefits of Anti-Static Mining Cables for Explosive Coal Environments

 

 

 

Feature Benefit
ATEX Compliance Ensures safety in explosive environments
Static Discharge Protection Prevents sparks and explosions caused by static electricity
Fire Resistance Protects against ignition from high temperatures and sparks
Flexibility Allows for easy installation in dynamic mining environments
Durability Withstands harsh conditions like abrasion, oil, and UV exposure
Enhanced Safety Minimizes the risk of hazardous situations during operation

 

 

Choosing the Right Anti-Static Mining Cable

 

 

When selecting an anti-static mining cable for your operation, consider the following factors:

 

 

 

Voltage and Current Ratings: Make sure the cable is rated for the voltage and current your system requires. Selecting a cable that’s under or over-rated can lead to safety hazards.

 

 

 

 

 

 

 

Temperature and Environmental Conditions: Ensure the cable can handle the environmental conditions it will be exposed to, including temperature extremes, chemical exposure, and mechanical stress.

 

 

 

 

 

 

 

Compliance with Local Standards: In addition to ATEX compliance, ensure the cable meets any other local standards for explosive environments. This may include certifications like IECEx or UL for various international regions.

 

 

 

 

 

 

 

Cable Size and Type: The diameter and type of conductor are critical when choosing the appropriate cable for your needs. Ensure that the cable size suits the distance it needs to cover and the equipment it will be connected to.

 

 

Applications of Anti-Static Mining Cables in Explosive Coal Environments

 

 

Underground Coal Mines: These cables are designed for use in underground coal mines, where the risk of static discharge and gas explosions is high. The anti-static mining cable ensures safety and reliability in these critical environments.

 

 

 

 

 

 

 

Surface Mining Operations: Surface coal mines also require robust, durable cables to withstand harsh conditions. Our ATEX-compliant mining cables are perfect for these applications, ensuring continuous operation and safety.

 

 

 

 

 

 

 

Coal Processing Plants: In processing plants where coal is refined and prepared for transport, anti-static cables help maintain safe electrical connections and prevent hazardous static discharge.

 

 

 

 

 

 

 

Material Handling Systems: These cables are ideal for use in cranes, hoists, and conveyor systems used for material handling in mining operations, where consistent flexibility and safety are needed.

 

 

Anti-Static Mining Cable for Explosive Coal Environment - ATEX Compliant , Static Discharge Protected , Enhanced Safety 1

 

 

Key Advantages of Using Anti-Static Mining Cables

 

 

 

 

Reliability in Hazardous Areas: Ensures continued operation even in volatile, high-risk areas.

 

 

 

 

 

 

 

Increased Safety: Prevents static discharge that could lead to dangerous sparks or explosions.

 

 

 

 

 

 

 

Durability: Resistant to abrasion, oil, and chemical exposure, these cables last longer than standard cables in mining conditions.

 

 

 

 

 

 

 

Compliance with ATEX and Other Standards: Helps meet legal requirements for mining operations in explosive environments.

 

 

Conclusion

 

 

The Anti-Static Mining Cable is an essential component for any mining operation working in hazardous environments like coal mines. Its ATEX-compliant, static discharge-protected, and fire-resistant design ensures that it meets the stringent safety requirements of explosive coal environments, providing enhanced safety for both workers and equipment.

 

 

 

By understanding the features, installation guidelines, and benefits of these specialized cables, you can ensure a safer, more reliable mining operation. Make sure to choose the right anti-static mining cable that meets the unique demands of your operation, and stay compliant with safety regulations while reducing the risk of accidents.

 

 

 

For more information, or to request a custom quote for your specific application, contact us today. We’re here to provide you with the best solution for your mining needs.

 

 


 

RFQ: Common Questions and Answers

 

 

Q1: Are these cables suitable for use in underground mining operations?

 

 

 

Yes, our anti-static mining cables are designed specifically for use in underground coal mines and other explosive environments.

 

 

 

 

 

 

Q2: How do I ensure proper grounding during installation?

 

 

 

Proper grounding is essential to preventing static buildup. Ensure that the cable is grounded at both ends and any intermediate points. We recommend using specialized grounding equipment for optimal safety.

 

 

 

 

 

 

 

NSHTÖU-SM Heavy-Duty Cable 0.6/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 5 NSHTÖU-SM Heavy-Duty Cable 0.6/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 6 NSHTÖU-SM Heavy-Duty Cable 0.6/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 7

 

 

 

 

 

 

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.