Send Message
products
products
Home > products > LSZH Cable > Feichun Type FEBI Railway Signalling Cable: Robust and Reliable for Demanding Applications

Feichun Type FEBI Railway Signalling Cable: Robust and Reliable for Demanding Applications

Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: VDE 0250 Part 814

Model Number: FEBI Railway Signalling Cable

Payment & Shipping Terms

Minimum Order Quantity: 200 Meter

Price: 10-50 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 18,000 meters per week

Highlight:
Braid:
With Or Without Tinned Copper
Operating Temperature:
-20℃ To +70℃
Uv Resistant:
Withstands Sunlight Exposure
Available Lengths:
Custom Lengths Available
Smoke Emission:
Low
Installation Method:
Indoor/Outdoor
Low Smoke Emission:
Reduces Smoke Emission During Combustion
Color:
Black
Type:
Single Mode
Cable Type:
Low Smoke Zero Halogen
Flame Resistant:
Exhibits Excellent Resistance To Flames
Material:
Low Smoke Zero Halogen
Fire Safety:
Complies With Fire Safety Standards
Conductor Material:
Copper
Braid:
With Or Without Tinned Copper
Operating Temperature:
-20℃ To +70℃
Uv Resistant:
Withstands Sunlight Exposure
Available Lengths:
Custom Lengths Available
Smoke Emission:
Low
Installation Method:
Indoor/Outdoor
Low Smoke Emission:
Reduces Smoke Emission During Combustion
Color:
Black
Type:
Single Mode
Cable Type:
Low Smoke Zero Halogen
Flame Resistant:
Exhibits Excellent Resistance To Flames
Material:
Low Smoke Zero Halogen
Fire Safety:
Complies With Fire Safety Standards
Conductor Material:
Copper
Feichun Type FEBI Railway Signalling Cable: Robust and Reliable for Demanding Applications

Feichun Type FEBI Railway Signalling Cable: Robust and Reliable for Demanding Applications

 


 

I. Introduction

 

 

 

Railway signalling systems are the backbone of safe and efficient train operations. The Feichun Type FEBI Railway Signalling Cable is a specially designed solution tailored for these critical applications.

 

 

Feichun Type FEBI Railway Signalling Cable: Robust and Reliable for Demanding Applications 0

 

 

 

It meets the stringent requirements for light signals, point machines, and other signalling devices while being suitable for direct burial or installation in ducts. Its unique construction ensures increased mechanical protection, flame retardancy, and long-lasting performance.

 

 

 

 

Key Features and Benefits

 

 

 

Robust Mechanical Protection: Equipped with steel tape armouring to withstand physical damage during installation and operation, making it ideal for direct burial.

 

 

 

 

 

 

 

Flame Retardant: Complies with IEC EN 60332-1, minimizing fire propagation risks.

 

 

 

 

 

Water Resistance: Features longitudinal water blocking to prevent water ingress and migration.

 

 

 

 

 

 

Ease of Installation: Engineered for direct burial, reducing installation costs and simplifying deployment.

 

 

 

 

 

This article will detail the technical specifications, standards compliance, common challenges, and best practices for installing and maintaining the Feichun Type FEBI Railway Signalling Cable, making it a go-to resource for railway signalling professionals.

 

 

 


II. Technical Specifications

 

 

The Feichun Type FEBI Railway Signalling Cable is built to perform in challenging environments. Below is a detailed breakdown of its technical specifications:

 

 

A. Conductor Characteristics

 

 

Property Specification
Material Copper
Stranding Pattern n x 1 x 1.5/2.5 mm
Cross-Sectional Area 1.5 mm², 2.5 mm²
Resistance at 20°C ≤ 12.1 Ω/km (1.5 mm²)
  ≤ 7.41 Ω/km (2.5 mm²)

 

 

B. Insulation and Construction

 

 

 

Layer Material Key Benefits
Core Insulation Polyethylene (PE) Excellent electrical properties
Longitudinal Water Blocking Yes Prevents water ingress
Inner Sheath Polyethylene (PE) Durable and resistant to moisture
Armouring/Reinforcement Steel Tape Superior mechanical protection
Outer Sheath Halogen-Free Flame Retardant PE Enhances safety and environmental compliance

 

 

C. Electrical Properties

 

 

 

Property Specification
Nominal Voltage (U) 750 V
Test Voltage (50 Hz, 1 min) 12 kV (Core/Core & Core/Screen)
Insulation Resistance ≥ 1,000 MΩ·km

 

 

 

 

D. Environmental Conditions

 

Condition Specification
Operating Temperature -30°C to +70°C
Installation Temperature -10°C to +50°C

 

 

 

 

E. Mechanical Properties

 

Property Specification
Bending Radius ≥ 10 x outer diameter (multiple bending)
  ≥ 7.5 x outer diameter (final bending)

 

 

 

 

These features make Feichun Type FEBI a versatile and dependable cable for railway signalling applications.

 

 

 


III. Standards and Compliance

 

A. Importance of Standards

 

 

Railway cables must adhere to stringent standards to ensure interoperability, safety, and long-term reliability. The Feichun Type FEBI cable complies with the following key standards:

 

 

Bane Nor Specification (Norway): Governs the design and performance of cables used in Norwegian railway systems.

 

 

 

IEC EN 60332-1: Specifies flame retardancy requirements, ensuring safety in fire-prone environments.

 

 

Compliance with these standards guarantees that the cable meets international safety and performance benchmarks.

 

 


IV. Common Challenges and Solutions

 

 

Railway signalling cables face unique challenges, especially in direct burial applications. The Feichun Type FEBI cable is designed to address these challenges effectively:

 

 

A. Mechanical Damage

 

 

  • Challenge: Rocks, debris, and ground movement can damage buried cables.

 

 

  • Solution: The steel tape armouring provides robust mechanical protection, preventing physical damage during and after installation.

 

 

B. Water Ingress

 

  • Challenge: Water ingress can degrade cable performance.

 

 

  • Solution: Longitudinal water blocking ensures that water cannot migrate within the cable, preserving its integrity.

 

 

C. Fire Hazards

 

  • Challenge: Flame spread in signalling cables can be catastrophic.

 

 

  • Solution: Flame retardancy compliance with IEC EN 60332-1 minimizes fire risks, enhancing safety.

 

 

D. Installation Difficulties

 

  • Challenge: Bending and pulling cables in trenches can cause damage.

 

 

  • Solution: The cable's flexible construction and adherence to specific bending radii ensure ease of handling during installation.

 

 


Feichun Type FEBI Railway Signalling Cable: Robust and Reliable for Demanding Applications 1

 

V. Installation and Maintenance Best Practices

 

 

A. Installation Guidelines

 

 

Trenching: Ensure the trench is of adequate depth and width, with a smooth bed of sand or fine soil.

 

 

Backfilling: Use soft materials to cover the cable before compacting the trench to avoid direct contact with sharp objects.

 

 

Route Identification: Install visible cable markers to prevent accidental damage during future excavations.

 

 

 

B. Maintenance Recommendations

 

 

Periodic Inspections: Check the cable route for signs of ground movement or potential hazards.

 

 

Electrical Testing: Conduct routine tests to ensure signal integrity and performance.

 

 

Connector Maintenance: Inspect terminations and connectors for signs of wear or water ingress.

 

 

 


VI. Advantages of Feichun Type FEBI Cable

 

 

A. Material Excellence

 

 

  • Steel Tape Armouring: Provides unparalleled mechanical protection.

 

 

  • Halogen-Free Outer Sheath: Ensures environmental compliance and reduces smoke toxicity in case of fire.

 

 

B. Manufacturing Superiority

 

  • Designed and manufactured to meet Bane Nor specifications, ensuring suitability for Norwegian railway systems.

 

 

  • Rigorous quality control ensures consistent performance in demanding conditions.

 

 

C. Cost-Effectiveness

 

  • Direct burial capability reduces installation costs.

 

  • Long lifespan minimizes the need for frequent replacements.

 

 


VII. Conclusion

 

The Feichun Type FEBI Railway Signalling Cable is an exceptional choice for demanding railway applications, particularly in direct burial scenarios. Its compliance with Bane Nor specifications and IEC EN 60332-1 standards ensures safety, reliability, and long-term performance.

 

 

By addressing common challenges and emphasizing proper installation and maintenance, this cable proves itself as a dependable solution for railway professionals.

 

 

Whether you’re a signalling engineer, installation contractor, or maintenance technician, the Feichun Type FEBI Railway Signalling Cable offers the peace of mind and performance you need to keep railway systems running smoothly.