Send Message
products
products
Home > products > LSZH Cable > Feichun AJ-2Y(L)2YDB2Y (H45): Robust Railway Signalling Cable with Enhanced Interference and Mechanical Protection for Direct Burial

Feichun AJ-2Y(L)2YDB2Y (H45): Robust Railway Signalling Cable with Enhanced Interference and Mechanical Protection for Direct Burial

Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: VDE 0250 Part 814

Model Number: AJ-2Y(L)2YDB2Y (H45)

Payment & Shipping Terms

Minimum Order Quantity: 200 Meter

Price: 10-30 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 18,000 meters per week

Highlight:
Fiber Count:
2
Urban Expansion:
Facilitates City Growth
Temperature Rating:
-20°C To 60°C
Flexibility:
Easy Adaptation To Tunnel Contours
Max Speed:
Up To 10 M/s
Crush Resistance:
≥1000N/100mm
High Conductivity:
Optimal Power Transmission Efficiency
Available Lengths:
Custom Lengths Available
Rohs Compliant:
Adheres To RoHS Environmental Standards
Jacket Material:
LSZH
Available Sizes:
Various Sizes Available
Flame Resistance:
Superior Fire Safety
Outer Diameter:
6.5-40mm
Chemical Resistant:
Resists Damage From Industrial Chemicals
Fiber Count:
2
Urban Expansion:
Facilitates City Growth
Temperature Rating:
-20°C To 60°C
Flexibility:
Easy Adaptation To Tunnel Contours
Max Speed:
Up To 10 M/s
Crush Resistance:
≥1000N/100mm
High Conductivity:
Optimal Power Transmission Efficiency
Available Lengths:
Custom Lengths Available
Rohs Compliant:
Adheres To RoHS Environmental Standards
Jacket Material:
LSZH
Available Sizes:
Various Sizes Available
Flame Resistance:
Superior Fire Safety
Outer Diameter:
6.5-40mm
Chemical Resistant:
Resists Damage From Industrial Chemicals
Feichun AJ-2Y(L)2YDB2Y (H45): Robust Railway Signalling Cable with Enhanced Interference and Mechanical Protection for Direct Burial

Feichun AJ-2Y(L)2YDB2Y (H45): Robust Railway Signalling Cable with Enhanced Interference and Mechanical Protection for Direct Burial

 

 

 

 

 


I. Introduction

 

 

A. Overview of Feichun AJ-2Y(L)2YDB2Y (H45)

 

 

 

 

The Feichun AJ-2Y(L)2YDB2Y (H45) is a premium railway signaling cable engineered to transmit low-frequency signals through symmetric circuits, such as those used in axle counters.

 

 

 

Feichun AJ-2Y(L)2YDB2Y (H45): Robust Railway Signalling Cable with Enhanced Interference and Mechanical Protection for Direct Burial 0

 

 

Designed for direct burial and installation in ducts, this cable is built to endure the most demanding railway environments, particularly along electrified tracks.

 

 

 

Its robust construction includes induction protection and mechanical reinforcement, ensuring reliable performance and longevity.

 

 

 

 

 

 

B. Key Features and Benefits

 

 

  • Optimized for Railway Signaling: Ideal for critical applications such as axle counters.

 

  • Enhanced Induction Protection: Copper wire screening mitigates inductive interference from electrified tracks.

 

 

 

  • Robust Mechanical Protection: Steel tape armouring safeguards against physical damage.

 

 

 

  • Direct Burial Capability: Eliminates the need for additional protective conduits, reducing installation complexity and cost.

 

 

 

 

Feichun AJ-2Y(L)2YDB2Y (H45): Robust Railway Signalling Cable with Enhanced Interference and Mechanical Protection for Direct Burial 1

 

 

C. Target Audience

 

 

 

This product is tailored for:

 

 

  • Railway signaling engineers

 

  • Installation contractors

 

  • Maintenance personnel

 

 

 

These professionals require a reliable solution for signal transmission in harsh conditions, including direct burial environments.

 

 

 


II. Technical Specifications

 

 

 

Parameter Details
Conductor Copper, n x 4 x 0.9/1.4 mm (star-quad stranding).
Core Insulation Polyethylene (PE)
Monitoring Conductor Copper, 0.5 mm with PE perforation (≥ 7 quads).
Inner Sheath Polyethylene (PE)
Intermediate Sheath Polyethylene (PE)
Screen Construction Copper wire screen.
Armouring/Reinforcement Galvanized steel tape for superior mechanical durability.
Outer Sheath Polyethylene (PE) for environmental protection.
Electrical Characteristics Loop Resistance: ≤ 56.6 Ω (0.9 mm), ≤ 23.4 Ω (1.4 mm).
Insulation Resistance: ≥ 10,000 MΩ·km.
Capacitance: ≤ 45 nF/km.
Environmental Conditions Operating Temp: -40°C to +60°C.
Laying Temp: -10°C to +60°C.
Bending Radius Multiple bends: ≥ 10x outer diameter.
Final bends: ≥ 7.5x outer diameter.

 

 

III. Standards and Compliance

 

 

A. Importance of Standards Compliance

 

 

Compliance with industry standards ensures safety, reliability, and interoperability in railway systems.

 

 

 

B. Key Standards

 

 

Deutsche Bahn AG 416.0115 V 1.1: Specifies the technical requirements for railway signaling cables.

 

 

Deutsche Bahn AG 416.0116 V 2.0: Complements the previous standard, emphasizing performance in electrified railway environments.

 

 

 


IV. Common Challenges in Railway Signaling Applications and Solutions

 

 

 

Challenge Feichun AJ-2Y(L)2YDB2Y (H45) Solution
Inductive Interference Copper wire screen minimizes signal interference, ensuring consistent performance.
Mechanical Damage (Direct Burial) Steel tape armouring protects against external forces and ground movement.
Water Ingress Multi-layer PE sheaths and laminated sheath prevent water penetration.
Signal Integrity Over Long Distances Optimized electrical properties ensure clear signal transmission.
Rodent Attack Steel armouring offers added protection against rodent damage.

 

 

V. Installation and Maintenance Best Practices for Direct Burial

 

 

Feichun AJ-2Y(L)2YDB2Y (H45): Robust Railway Signalling Cable with Enhanced Interference and Mechanical Protection for Direct Burial 2

 

 

A. Proper Trenching and Bedding

 

 

Depth and Width: Ensure trenches are deep and wide enough to prevent surface pressure damage.

 

 

Smooth Bedding: Lay the cable on a bed of sand or fine soil to protect against sharp objects.

 

 

 

B. Backfilling and Compaction

 

 

Use soft, non-abrasive materials to backfill trenches.

 

 

Compact in layers to ensure cable stability and prevent future ground shifts.

 

 

 

C. Cable Markers and Route Identification

 

 

Place clear markers to identify cable routes and minimize accidental excavation damage.

 

 

 

D. Correct Termination and Connections

 

 

Utilize compatible connectors and ensure proper grounding for copper screens.

 

 

E. Regular Inspection and Maintenance

 

 

Conduct periodic electrical tests to monitor signal integrity.

 

 

Inspect the cable route for potential threats like ground disturbances or water pooling.

 

 

 


Feichun AJ-2Y(L)2YDB2Y (H45): Robust Railway Signalling Cable with Enhanced Interference and Mechanical Protection for Direct Burial 3

 

VI. Advantages of Feichun AJ-2Y(L)2YDB2Y (H45)

 

 

A. Material Benefits

 

 

  • High-Quality Polyethylene (PE): Durable and environmentally resistant.

 

 

  • Galvanized Steel Armouring: Exceptional protection against external impacts.

 

 

B. Manufacturing Excellence

 

  • Precision-engineered to meet Deutsche Bahn AG standards.

 

 

  • Advanced screening and sheathing techniques ensure longevity and reliability.

 

 


VII. Conclusion

 

 

The Feichun AJ-2Y(L)2YDB2Y (H45) railway signaling cable delivers unparalleled reliability for direct burial and installation in ducts, meeting the rigorous demands of electrified railway environments.

 

 

With superior induction protection, mechanical durability, and compliance with Deutsche Bahn AG standards, this cable is the ultimate choice for railway signaling professionals.

 

 

For professionals seeking a robust, cost-effective solution, Feichun AJ-2Y(L)2YDB2Y (H45) ensures long-term performance and safety in critical railway applications.

 

 


Choose Feichun for your railway signaling needs—where performance meets durability.