Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: VDE 0250 Part 814

Model Number: A-2YOF(L)2YB2Y H145

Payment & Shipping Terms

Minimum Order Quantity: 200 Meter

Price: 10-60 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 16,000 meters per week

Highlight:
Flame Retardant:
Yes
Temperature Rating:
-40°C To +90°C
Crush Resistance:
≥1000N/100mm
Flexible:
Yes
High Conductivity:
Optimal Power Transmission Efficiency
Cable Type:
Low Smoke Zero Halogen
Jacket Material:
LSZH (Low Smoke Zero Halogen)
Chemical Resistant:
Resists Damage From Industrial Chemicals
Flame Resistance:
Superior Fire Safety
Optimal Cable Management:
Facilitates Efficient Cable Organization
Abrasion Resistant:
Yes
Available Lengths:
Custom Lengths Available
Outer Diameter:
6.5-40mm
Rohs Compliant:
Adheres To RoHS Environmental Standards
Flame Retardant:
Yes
Temperature Rating:
-40°C To +90°C
Crush Resistance:
≥1000N/100mm
Flexible:
Yes
High Conductivity:
Optimal Power Transmission Efficiency
Cable Type:
Low Smoke Zero Halogen
Jacket Material:
LSZH (Low Smoke Zero Halogen)
Chemical Resistant:
Resists Damage From Industrial Chemicals
Flame Resistance:
Superior Fire Safety
Optimal Cable Management:
Facilitates Efficient Cable Organization
Abrasion Resistant:
Yes
Available Lengths:
Custom Lengths Available
Outer Diameter:
6.5-40mm
Rohs Compliant:
Adheres To RoHS Environmental Standards
Comprehensive Guide to Feichun A-2YOF(L)2YB2Y H145 Railway Signalling Cable

Comprehensive Guide to Feichun A-2YOF(L)2YB2Y H145 Railway Signalling Cable

 

Railway signalling systems are the backbone of safe and efficient train operations. The Feichun A-2YOF(L)2YB2Y H145 Railway Signalling Cable is specially designed to meet the rigorous demands of railway applications, offering exceptional performance, durability, and compliance with Deutsche Bahn AG PH 416.0113 v.2.1 standards.

 

 

Comprehensive Guide to Feichun A-2YOF(L)2YB2Y H145 Railway Signalling Cable 0

 

 

 

This guide provides an in-depth look at the features, benefits, and installation practices of this robust cable.

 

 


 

 

 

The Feichun A-2YOF(L)2YB2Y H145 cable is purpose-built for light signal and point machine operations in railway systems. Its advanced design ensures reliable performance in underground and duct installations, where enhanced mechanical protection is crucial.

 

 

 

With its steel tape armoring and water-blocking system, this cable is a top choice for railway applications in harsh environments.

 

 

 

1.2 Standards Compliance

 

 

This cable complies with the Deutsche Bahn AG PH 416.0113 v.2.1 standards, ensuring superior performance and safety.

 

 

 

It is rated for a nominal voltage of 420/600V, with stringent testing requirements for insulation resistance, capacitance, and mechanical protection.

 

 

 


2. Technical Construction

 

 

2.1 Conductor Specifications

 

 

 

The cable features a bare copper conductor with a stranding pattern of n x 1 x 1.4/1.8 mm, offering high conductivity and durability. The table below highlights the conductor specifications:

 

 

 

Conductor Diameter Resistance (Ohm/km at 20°C) Material
1.4 mm ≤ 11.9 Bare Copper
1.8 mm ≤ 7.2 Bare Copper

 

 

 

 

2.2 Cable Design

 

The multi-layer construction enhances the cable's performance and longevity:

 

 

 

Layer Material Function
Core Insulation Polyethylene (PE) Electrical insulation
Shielding Layer Copolymer Coated Al-tape Electromagnetic interference protection
Armoring Galvanized Steel Tape Mechanical protection
Inner and Outer Sheaths PE Environmental protection
Water Blocking System Longitudinal Blocking Prevents water ingress

 

3. Electrical Properties

 

 

3.1 Operating Parameters

 

 

The Feichun A-2YOF(L)2YB2Y H145 cable offers exceptional electrical characteristics:

 

 

 

Parameter Value
Insulation Resistance ≥ 1500 MΩ∙km
Maximum Capacitance ≤ 145 nF/km
Special Case Capacitance ≤ 155 nF/km (single core)
Voltage Testing Requirements 2.5 kV

 

 

 

 

3.2 Performance Characteristics

 

 

  • Signal Transmission: Maintains high signal integrity, critical for railway operations.

 

  • EMI Protection: Robust shielding ensures minimal electromagnetic interference.

 

  • Temperature Stability: Performs reliably across -40°C to +60°C.

 

 

  • Longevity: Designed for long-term reliability in demanding conditions.

 

 

 


4. Installation Requirements

 

4.1 Environmental Conditions

 

 

The cable is designed for direct burial or duct installations, ensuring performance in various environments.

 

 

 

Condition Operating Range
Temperature - Operation -40°C to +60°C
Temperature - Installation -10°C to +60°C

 

 

 

4.2 Mechanical Installation

 

 

To ensure optimal performance, follow these mechanical guidelines:

 

 

 

Installation Aspect Specification
Bending Radius - Multiple ≥ 10 x diameter
Bending Radius - Final ≥ 7.5 x diameter
Pulling Force Calculated based on cable size

 

 

 

 


5. Railway Applications

 

 

5.1 Light Signal Systems

 

 

The cable ensures seamless integration with light signal systems, offering reliable power and signal transmission. Proper shielding and insulation maintain signal integrity even in high-interference environments.

 

 

 

5.2 Point Machine Operations

 

 

For point machines, the cable delivers consistent power distribution and control signal transmission, ensuring smooth railway operations and enhancing safety protocols.

 

 

 


Comprehensive Guide to Feichun A-2YOF(L)2YB2Y H145 Railway Signalling Cable 1

 

6. Testing and Verification

 

 

6.1 Factory Testing

 

 

Test Type Methodology
Conductor Resistance Measured at 20°C
Insulation Resistance ≥ 1500 MΩ∙km
Voltage Testing 2.5 kV for core-to-core/screen

 

 

 

 

6.2 Field Testing

 

 

Field testing ensures proper installation and system performance:

 

 

 

Test Type Purpose
Installation Verification Ensures proper laying of cable
Performance Validation Confirms operational parameters

 

 

 

 


7. Common Installation Challenges

 

 

7.1 Physical Installation

 

 

Key challenges include maintaining bending radius specifications and using proper pulling techniques to avoid damage.

 

 

 

7.2 Environmental Protection

 

 

Preventing water ingress, managing temperature variations, and providing adequate mechanical protection are critical for underground installations.

 

 


Comprehensive Guide to Feichun A-2YOF(L)2YB2Y H145 Railway Signalling Cable 2

 

8. Maintenance Guidelines

 

 

8.1 Preventive Maintenance

 

 

  • Conduct regular inspections to identify wear or damage.

 

  • Verify insulation resistance and capacitance periodically.

 

  • Maintain detailed documentation for compliance.

 

 

 

8.2 Troubleshooting

 

If faults occur, follow these steps:

 

 

Issue Testing Method Resolution
Signal Loss Capacitance Testing Replace damaged sections
Water Ingress Visual Inspection Seal and reinforce

 

 

 

 


9. Quality Control

 

9.1 Manufacturing Standards

 

 

Feichun ensures quality through rigorous material selection, construction processes, and testing protocols, adhering to Deutsche Bahn AG standards.

 

 

 

9.2 Performance Monitoring

 

 

Feichun cables undergo long-term reliability assessments to identify improvement opportunities and ensure consistent performance.

 

 

 


10. Safety Considerations

 

 

10.1 Installation Safety

 

 

  • Use personal protective equipment during installation.

 

  • Follow safe working practices to minimize risks.

 

 

 

10.2 Operational Safety

 

 

  • Adhere to voltage limitations to prevent overheating.

 

 

  • Ensure proper grounding and termination methods.

 

 

 


11. References

 

Deutsche Bahn AG PH 416.0113 v.2.1 Standards

 

Feichun Installation Manuals

 

Railway Industry Testing Procedures

 

 


By choosing the Feichun A-2YOF(L)2YB2Y H145 Railway Signalling Cable, you invest in reliability, safety, and long-term performance. With its advanced design and robust construction, this cable is the ideal choice for modern railway systems.

 

 

 

Contact Feichun today to learn more about how this product can enhance your railway operations!