Send Message
products
products
Home > products > LSZH Cable > Comprehensive Guide to Feichun A-2YOF(L)2YB2Y H115 Railway Signaling Cable

Comprehensive Guide to Feichun A-2YOF(L)2YB2Y H115 Railway Signaling Cable

Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: VDE 0250 Part 814

Model Number: A-2YOF(L)2YB2Y H115

Payment & Shipping Terms

Minimum Order Quantity: 200 Meter

Price: 10-50 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 18,000 meters per week

Highlight:
Fiber Count:
2
Chemical Resistant:
Resists Damage From Industrial Chemicals
Jacket Material:
LSZH (Low Smoke Zero Halogen)
Type:
Single Mode
Flame Resistant:
Exhibits Excellent Resistance To Flames
Cable Type:
Low Smoke Zero Halogen
Halogen Content:
Zero
Outer Jacket:
PUR
Zero Halogen:
Formulated Without Halogen Elements
Fire Safety:
Complies With Fire Safety Standards
Low Toxicity:
Minimizes The Release Of Toxic Gases
Flame Retardant:
Yes
Underground Power:
Reliable Power Transmission
Flexibility:
Easy Adaptation To Tunnel Contours
Fiber Count:
2
Chemical Resistant:
Resists Damage From Industrial Chemicals
Jacket Material:
LSZH (Low Smoke Zero Halogen)
Type:
Single Mode
Flame Resistant:
Exhibits Excellent Resistance To Flames
Cable Type:
Low Smoke Zero Halogen
Halogen Content:
Zero
Outer Jacket:
PUR
Zero Halogen:
Formulated Without Halogen Elements
Fire Safety:
Complies With Fire Safety Standards
Low Toxicity:
Minimizes The Release Of Toxic Gases
Flame Retardant:
Yes
Underground Power:
Reliable Power Transmission
Flexibility:
Easy Adaptation To Tunnel Contours
Comprehensive Guide to Feichun A-2YOF(L)2YB2Y H115 Railway Signaling Cable

Comprehensive Guide to Feichun A-2YOF(L)2YB2Y H115 Railway Signaling Cable

 

Railway signaling systems demand reliability, safety, and durability. The Feichun A-2YOF(L)2YB2Y H115 Railway Signaling Cable is a specialized solution designed to meet these demands.

 

 

Comprehensive Guide to Feichun A-2YOF(L)2YB2Y H115 Railway Signaling Cable 0

 

 

 

Whether it's powering light signals, operating point machines, or other signaling applications, this cable provides exceptional performance in challenging environments. Let's dive into its features, construction, applications, and the knowledge you need to install and maintain it effectively.

 

 

 

 

 

The Feichun A-2YOF(L)2YB2Y H115 Railway Signaling Cable is engineered to support light signal systems, point machines, and similar applications. Key attributes include:

 

 

 

 

  • Compliance with Deutsche Bahn AG PH 416.0113 v.2.1 standards for assured reliability.

 

 

 

  • Designed for direct installation into the ground or ducts, ensuring versatility.

 

 

 

 

  • Enhanced mechanical protection through steel tape armoring, making it suitable for harsh conditions.

 

 

 

  • Optimized for longitudinal water blocking, which prevents water ingress and ensures uninterrupted performance.

 

 

 

 

 

1.2 Key Features

 

 

  • Bare copper conductor with excellent conductivity.

 

  • High resistance to environmental stress due to PE insulation and sheathing.

 

  • Steel tape armoring for mechanical robustness.

 

  • Monitoring conductors to ensure the integrity of the system.

 

 

 


Comprehensive Guide to Feichun A-2YOF(L)2YB2Y H115 Railway Signaling Cable 1

 

2. Technical Construction

 

 

2.1 Conductor Specifications

 

 

 

Parameter Specification
Conductor Diameter 0.9 mm
Stranding Pattern n x 1 x 0.9 mm
Conductor Resistance ≤ 28.9 Ohm/km at 20°C
Monitoring Conductor Cu 0.5 mm PE perforated

 

 

 

 

The bare copper conductor ensures high conductivity, while the monitoring conductor adds an extra layer of operational security.

 

 

 

2.2 Cable Layer Construction

 

 

 

Layer Material Features
Core Insulation PE High dielectric strength
Inner Sheath PE Environmental protection
Armor Layer Galvanized Steel Tape Enhanced mechanical protection
Outer Sheath PE UV resistance and durability

 

 

 

 

 

This multi-layered design ensures protection against environmental and mechanical stresses.

 

 

 


Comprehensive Guide to Feichun A-2YOF(L)2YB2Y H115 Railway Signaling Cable 2

 

3. Electrical Characteristics

 

 

3.1 Operating Parameters

 

 

Parameter Value
Nominal Voltage U₀/U: 420/600V
Capacitance ≤ 115 nF/km (≤ 120 nF/km for single core)
Insulation Resistance ≥ 1500 MΩ∙km

 

 

 

 

These parameters ensure reliable performance over long distances and in high-stress environments.

 

 

3.2 Testing Requirements

 

 

Test Type Specification
Core-to-Core Voltage 2.5 kV
Core-to-Screen Voltage 2.5 kV

 

 

 

 

 

Testing is performed rigorously to guarantee compliance with industry standards and long-term reliability.

 

 

 


Comprehensive Guide to Feichun A-2YOF(L)2YB2Y H115 Railway Signaling Cable 3

 

4. Installation Guidelines

 

 

4.1 Environmental Parameters

 

 

Condition Operating Range
Temperature -40°C to +60°C
Installation -10°C to +60°C

 

 

 

 

 

For underground installations, it’s vital to follow proper duct and burial procedures to maximize cable longevity.

 

 

 

4.2 Mechanical Installation

 

 

Parameter Specification
Bending Radius ≥ 10 x cable diameter (multiple bending)
  ≥ 7.5 x cable diameter (final bending)

 

 

 

 

 

Proper techniques for pulling, supporting, and terminating the cable are critical to maintaining its structural integrity.

 

 

 


Comprehensive Guide to Feichun A-2YOF(L)2YB2Y H115 Railway Signaling Cable 4

 

5. Railway Applications

 

 

5.1 Light Signal Systems

 

 

  • Ensures signal integrity over long distances.

 

  • Compatible with modern signal control systems.

 

 

  • Resistant to environmental and mechanical disruptions.

 

 

 

5.2 Point Machine Operations

 

 

  • Provides reliable power distribution for critical operations.

 

  • Integrates seamlessly with control systems.

 

  • Designed for safe and efficient operation under varying conditions.

 

 


Comprehensive Guide to Feichun A-2YOF(L)2YB2Y H115 Railway Signaling Cable 5

 

6. Testing and Verification

 

 

6.1 Pre-installation Testing

 

 

Test Purpose
Conductor Continuity Verify uninterrupted conductivity
Insulation Resistance Ensure high dielectric strength

 

 

 

 

6.2 System Integration Testing

 

 

  • Assess signal quality post-installation.

 

  • Verify system performance under operational conditions.

 

 

 


7. Installation Challenges

 

 

7.1 Physical Installation

 

 

  • Use proper pulling techniques to avoid mechanical stress.

 

  • Ensure adherence to bending radius requirements to maintain cable integrity.

 

 

 

 

 

7.2 Environmental Protection

 

 

  • Prevent water ingress using longitudinal water blocking systems.

 

  • Protect against mechanical and environmental damage during installation.

 

 


Comprehensive Guide to Feichun A-2YOF(L)2YB2Y H115 Railway Signaling Cable 6

 

8. Maintenance Procedures

 

 

8.1 Preventive Maintenance

 

 

Task Frequency
Visual Inspections Quarterly
Electrical Testing Annually

 

 

 

 

 

Regular maintenance ensures optimal performance and early detection of potential issues.

 

 

 

8.2 Troubleshooting Guide

 

 

  • Identify common faults using standard testing procedures.

 

 

  • Implement timely repairs to avoid prolonged downtime.

 

 


9. Safety and Compliance

 

 

9.1 Installation Safety

 

 

  • Wear personal protective equipment (PPE).

 

 

  • Conduct risk assessments before starting any installation.

 

 

 

9.2 Regulatory Compliance

 

 

  • Fully adheres to Deutsche Bahn AG PH 416.0113 v.2.1 standards.

 

  • Meets national and international safety requirements.

 

 

 


10. Quality Control

 

 

10.1 Manufacturing Standards

 

 

Process Focus Area
Material Selection Ensure high-quality raw materials
Construction Integrity Maintain design specifications

 

 

 

 

10.2 Field Performance

 

 

  • Evaluate long-term reliability through field testing.

 

 

  • Monitor for performance improvements and optimizations.

 

 

 


11. Conclusion

 

 

The Feichun A-2YOF(L)2YB2Y H115 Railway Signaling Cable is a superior choice for railway signaling applications, combining high performance, durability, and compliance with Deutsche Bahn standards. Its robust construction and advanced features make it the ideal solution for light signals, point machines, and other critical operations. By following proper installation and maintenance practices, this cable will ensure reliable performance for years to come.

 

 

For more details or to discuss your specific requirements, contact Feichun Cable today.

 

 

 

 

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

 

 

 

 

 

 

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.