Send Message
products
products
Home > products > Mining Trailing Cable > Comprehensive Guide to Feichun PROTODUR (N)AStYY 0.6/1kV Railway Earthing Cables

Comprehensive Guide to Feichun PROTODUR (N)AStYY 0.6/1kV Railway Earthing Cables

Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: VDE 0250 Part 814

Model Number: PROTODUR (N)AStYY 0.6/1kV

Payment & Shipping Terms

Minimum Order Quantity: 200 Meter

Price: 10-50 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 18,000 meters per week

Highlight:
Material:
Special Compounds
Armor:
Galvanized Steel Interlocked Armor
Efficient Extraction:
Aids Mineral Extraction Efficiency
Outer Diameter:
1.5 Inches
Flexibility:
Extra Flexible
Bending Radius:
10 X Cable Diameter
Reliable Transmission:
Ensures Consistent Power Transmission
Maximum Tensile Strength:
20kN
Easy Installation:
Flexible Installation
Armour Type:
Steel Wire Armour
Versatile Compatibility:
Fits Various Equipment Configurations
Wind Power Application:
Ideal For Wind Farms
Weather Resistance:
Resilient In Diverse Weather
Optimized For Quarrying:
Designed For Quarrying Applications
Material:
Special Compounds
Armor:
Galvanized Steel Interlocked Armor
Efficient Extraction:
Aids Mineral Extraction Efficiency
Outer Diameter:
1.5 Inches
Flexibility:
Extra Flexible
Bending Radius:
10 X Cable Diameter
Reliable Transmission:
Ensures Consistent Power Transmission
Maximum Tensile Strength:
20kN
Easy Installation:
Flexible Installation
Armour Type:
Steel Wire Armour
Versatile Compatibility:
Fits Various Equipment Configurations
Wind Power Application:
Ideal For Wind Farms
Weather Resistance:
Resilient In Diverse Weather
Optimized For Quarrying:
Designed For Quarrying Applications
Comprehensive Guide to Feichun PROTODUR (N)AStYY 0.6/1kV Railway Earthing Cables

Comprehensive Guide to Feichun PROTODUR (N)AStYY 0.6/1kV Railway Earthing Cables

 

 

 

The Feichun PROTODUR (N)AStYY 0.6/1kV Single-Core Power/Earthing Cable is designed for fixed installations in railway systems, providing essential short-circuit proof PE-connection and potential equalization between rails and non-energized components.

 

 

Comprehensive Guide to Feichun PROTODUR (N)AStYY 0.6/1kV Railway Earthing Cables 0

 

 

 

Its robust design ensures reliability for applications such as:

 

 

  • Overhead line masts

 

  • Fixtures of train pre-heating devices

 

  • Sound protection panels

 

  • Guardrails

 

 

This cable's adaptability for various environments, including direct burial, installation in concrete, and outdoor exposure, ensures dependable performance in complex railway infrastructure.

 

 

 

1.2 Cable Innovation

 

 

  • Lead-free construction ensures compliance with modern environmental standards and contributes to sustainability.

 

 

  • UV resistance protects the cable from sun damage, enhancing longevity for outdoor applications.

 

 

  • Railway certification, including compliance with Rail-Directive 997.0205A01 and DB Netz AG product release PF-2022-0004, highlights its suitability for critical railway installations.

 

 

 


Comprehensive Guide to Feichun PROTODUR (N)AStYY 0.6/1kV Railway Earthing Cables 1

 

2. Technical Specifications

 

 

2.1 Conductor Construction

 

 

 

Property Details
Material Aluminum-magnesium alloy with steel wire core
Design Stranded and compacted, Class 2
Standards DIN EN 60228, DIN EN 50182

 

 

 

 

 

 

This robust design ensures a balance of lightweight construction and mechanical durability suitable for demanding railway applications.

 

 

 

2.2 Insulation System

 

 

 

Layer Material Key Features
Core Insulation PVC High dielectric strength
Outer Sheath PVC Resistance to UV, moisture, and chemicals
Shape Round Easy handling and installation

 

 

 

 

Temperature ratings:

 

Continuous operation: 70°C

 

Short-circuit: 160°C


 

 

3. Standards and Certifications

 

3.1 Compliance Framework

 

 

 

Standard Requirement
Rail-Directive 997.0205A01 Railway earthing cable specifications
DIN VDE 0276-603 Fixed installation requirements
DIN EN 60228 Conductor standards
DIN EN 60332-1-2 Fire resistance

 

 

 

 

3.2 Testing and Verification

 

 

Test Specification
Test Voltage 4 kV
Short-Circuit Current Custom calculations based on installation
Performance Validation Tests for current-carrying capacity and thermal behavior

 

4. Installation Guidelines

 

 

4.1 Installation Methods

 

 

Method Key Considerations
Direct Burial Proper soil preparation
Tube Installation Use protective conduits
Track Bed Secured against vibrations
Indoor Avoid tight bends
Concrete Ensure it is not compacted
Underwater Verify sealing and insulation integrity

 

 

 

 

4.2 Installation Parameters

 

 

Parameter Value
Operating Temperature -5°C to 70°C
Bending Radius Multiple bends: 15 × D; Single bend: 7.5 × D
Tensile Strength 30 N/mm²

 

 

 

 


Comprehensive Guide to Feichun PROTODUR (N)AStYY 0.6/1kV Railway Earthing Cables 2

 

 

5. Environmental Factors

 

 

5.1 Temperature Considerations

 

 

 

Factor Impact
Ambient Temperature Affects current-carrying capacity
Seasonal Fluctuations Requires temperature derating factors

 

 

 

 

5.2 Environmental Protection

 

 

 

 

UV resistance ensures long-term outdoor performance.

 

 

Moisture protection prevents water ingress.

 

 

Chemical resistance mitigates risks from corrosive agents.

 

 

 


6. Short-Circuit Protection

 

 

6.1 Current Calculations

 

 

 

Formula Purpose
 
I=StI = frac{S}{sqrt{t}} Calculate short-circuit current based on cross-section SS and time tt.

 

6.2 Protection Systems

 

 

Component Function
Grounding System Diverts fault currents
Protection Devices Ensures coordination with circuit breakers

 

 

 

 


Comprehensive Guide to Feichun PROTODUR (N)AStYY 0.6/1kV Railway Earthing Cables 3

 

7. Common Installation Challenges

 

 

7.1 Physical Installation

 

 

 

Challenge Solution
Cable Pulling Use proper tension limits
Bending Radius Follow recommended radii

 

 

 

 

7.2 Environmental Challenges

 

 

Challenge Solution
Temperature Fluctuations Seasonal adjustments during installation
Moisture Use watertight seals
UV Exposure Ensure UV-resistant outer sheath

 

 

 

 


8. Maintenance and Troubleshooting

 

 

8.1 Preventive Maintenance

 

 

Task Frequency
Visual Inspection Monthly
Testing Semi-annually
Documentation Review Annually

 

 

 

 

8.2 Problem Resolution

 

 

 

 

Issue Action
Damaged Sheath Replace affected section
Short Circuits Verify grounding and connections

 

 

 

 


9. Application Case Studies

 

 

9.1 Railway Applications

 

 

Application Details
Overhead Line Masts Grounding and equalization
Sound Panels Reliable earthing

 

 

 

 

9.2 Performance Analysis

 

 

Metric Result
Longevity >30 years with proper maintenance
Reliability High resistance to environmental stress

 

 

 

 


Comprehensive Guide to Feichun PROTODUR (N)AStYY 0.6/1kV Railway Earthing Cables 4

 

10. Technical Support

 

 

10.1 Documentation

 

 

Resource Availability
Installation Guides Provided by Feichun
Compliance Certificates Upon request

 

 

 

 

10.2 Support Resources

 

 

  • Technical Assistance: Contact Feichun for queries.

 

 

  • Training Programs: Enhance installation expertise.

 

 


11. References

 

  • DIN VDE 0276-603: Installation regulations

 

  • Rail-Directive 997.0205A01: Railway standards

 

  • Feichun Technical Manuals: Detailed product guides

 

 


 

 

 

The Feichun PROTODUR (N)AStYY 0.6/1kV Cable combines advanced materials, rigorous standards, and practical installation solutions to meet the demands of modern railway infrastructure.

 

 

Its lead-free, UV-resistant, and certified design ensures long-lasting performance across diverse environments, making it an ideal choice for rail operators worldwide. Contact Feichun Cable for expert guidance and support!

 

 

 

 

 

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

 

 

 

 

 

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.