Send Message
products
products
Home > products > Mining Trailing Cable > Feichun PROTOTHEN X (N)A2XS(F)2Y Single Core Track Feeder Cable 1.8/3KV: Reliable Power Distribution for Modern Railway

Feichun PROTOTHEN X (N)A2XS(F)2Y Single Core Track Feeder Cable 1.8/3KV: Reliable Power Distribution for Modern Railway

Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: VDE 0250 Part 814

Model Number: PROTOTHEN X (N)A2XS(F)2Y

Payment & Shipping Terms

Minimum Order Quantity: 200 Meter

Price: 10-50 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 18,000 meters per week

Highlight:
Outer Sheath Color:
Black
Abrasion Resistant:
Yes
Water Resistant:
Yes
Highly Reliable:
Trustworthy In Critical Tasks
Operating Temperature:
-40°C To +90°C
Reliable Transmission:
Ensures Consistent Power Transmission
Flexible Handling:
Easy Handling In Dynamic Conditions
Cable Type:
ROTOTHEN X (N)A2XS(F)2Y
Tailored For Handling:
Enhances Material Handling Efficiency
Outdoor Suitability:
Suited For Outdoor Use
Chemical Stability:
Stable In Chemical Environments
Resistant To Debris:
Guards Against Mining Debris
Outer Sheath Color:
Black
Abrasion Resistant:
Yes
Water Resistant:
Yes
Highly Reliable:
Trustworthy In Critical Tasks
Operating Temperature:
-40°C To +90°C
Reliable Transmission:
Ensures Consistent Power Transmission
Flexible Handling:
Easy Handling In Dynamic Conditions
Cable Type:
ROTOTHEN X (N)A2XS(F)2Y
Tailored For Handling:
Enhances Material Handling Efficiency
Outdoor Suitability:
Suited For Outdoor Use
Chemical Stability:
Stable In Chemical Environments
Resistant To Debris:
Guards Against Mining Debris
Feichun PROTOTHEN X (N)A2XS(F)2Y Single Core Track Feeder Cable 1.8/3KV: Reliable Power Distribution for Modern Railway

Feichun PROTOTHEN X (N)A2XS(F)2Y Single Core Track Feeder Cable 1.8/3KV: Reliable Power Distribution for Modern Railway

 

Overview of Railway Power Distribution Systems

 

 

Railway systems require highly reliable, durable, and efficient power distribution networks to ensure smooth and safe operations. These systems support a range of functions, from powering trains to running signalling and platform systems.

 

 

Feichun PROTOTHEN X (N)A2XS(F)2Y Single Core Track Feeder Cable 1.8/3KV: Reliable Power Distribution for Modern Railway 0

 

 

 

A key component of any railway power distribution infrastructure is the track feeder cable, which carries electrical power to the railway tracks and other essential components.

 

 

 

 

 

In modern railway applications, power distribution cables must be capable of operating in various environments, from underground tunnels to exposed tracks in all weather conditions.

 

 

 

 

 

This is where the Feichun PROTOTHEN X (N)A2XS(F)2Y Single Core Track Feeder Cable steps in, providing a versatile, high-performance solution for power distribution.

 

 

 

 

Critical Role of Track Feeder Cables in Railway Applications

 

 

 

Track feeder cables serve as the backbone of railway power systems, providing the necessary electrical current to railway tracks, signals, and power supply points.

 

 

 

These cables are responsible for ensuring trains have the power to operate efficiently, maintaining essential systems, and minimizing downtime due to power disruptions.

 

 

 

 

Significance of 1.8/3kV Distribution Cables in Modern Railway Infrastructure

 

 

 

The Feichun PROTOTHEN X (N)A2XS(F)2Y cable features a 1.8/3kV nominal voltage rating, making it ideal for high-performance railway distribution systems.

 

 

 

This voltage rating allows the cable to handle the significant power requirements of modern railways while remaining flexible and reliable in a variety of environments.

 

 

 


2. Technical Specifications and Construction

 

 

2.1 Core Construction

 

 

 

Specification Details
Conductor Material Bare Aluminum, Round Stranded (RM)
Conductor Type Aluminum Stranded (RM)
Conductivity High conductivity, suitable for long-distance power transmission
Flexibility Provides flexibility for easy installation in various environments
Tensile Strength 30 N/mm² tensile strength

 

Current Carrying Capacity Analysis

 

 

The bare aluminum conductor offers high conductivity, enabling it to carry large amounts of electrical current with minimal losses.

 

 

 

This is essential for maintaining consistent power supply in railway systems, even over long distances. The conductor’s flexibility ensures ease of handling and installation in tight spaces and complex configurations.

 

 

 

 

 

Feichun PROTOTHEN X (N)A2XS(F)2Y Single Core Track Feeder Cable 1.8/3KV: Reliable Power Distribution for Modern Railway 1

 

 

 

2.2 Insulation System

 

 

Specification Details
Insulation Material Cross-linked Polyethylene (XLPE)
Continuous Operating Temperature 90°C
Short Circuit Temperature 250°C (short-circuit)
Voltage Rating 1.8/3 kV (nominal), 3.6 kV (maximum)

 

 

XLPE Insulation Properties and Advantages

 

 

XLPE insulation is renowned for its high thermal stability, chemical resistance, and durability. It can withstand extreme temperatures and provide excellent protection against mechanical stress, water, and contaminants.

 

 

 

This makes the Feichun PROTOTHEN X (N)A2XS(F)2Y cable ideal for harsh railway environments, ensuring reliable performance under both normal and extreme conditions.

 

 

 

Temperature Rating Analysis

 

 

The 90°C continuous operating temperature and 250°C short-circuit temperature ratings ensure that the cable can handle the high thermal stresses encountered in railway power distribution systems without compromising performance or safety.

 

 

 

2.3 Screen and Water Blocking

 

 

Specification Details
Screen Material Copper Wire Screen
Water Blocking Mechanism Longitudinal Watertight Screen
Counterhelix Tape Applied to prevent water ingress and enhance screen integrity

 

 

Copper Wire Screen Construction

 

 

 

The copper wire screen provides electromagnetic shielding, reducing the risk of interference from external electrical sources. This is essential in railway systems where reliable data transmission and signal integrity are critical.

 

 

 

Longitudinal Water Blocking Technology

 

 

The longitudinal watertight screen prevents the ingress of water, ensuring that the cable continues to function even in wet conditions. This technology is especially beneficial for submerged installations, tunnels, and areas exposed to heavy moisture.

 

 

 

Screen Current Carrying Capacity

 

 

The screen in the Feichun PROTOTHEN X (N)A2XS(F)2Y cable also contributes to its current-carrying capacity, making it a robust choice for power distribution in environments where high electrical demands must be met.

 

 

 

2.4 Outer Sheath

 

 

Specification Details
Sheath Material Polyethylene (PE)
UV Resistance High UV resistance
Moisture and Chemical Resistance Designed to resist moisture and chemicals in harsh environments

 

 

Feichun PROTOTHEN X (N)A2XS(F)2Y Single Core Track Feeder Cable 1.8/3KV: Reliable Power Distribution for Modern Railway 2

 

Polyethylene (PE) Composition

 

 

The outer sheath of the PROTOTHEN X (N)A2XS(F)2Y cable is made of polyethylene (PE), providing excellent weather resistance, UV protection, and chemical resistance.

 

 

 

This ensures the cable can withstand outdoor conditions, including exposure to UV rays and chemicals commonly found in railway environments.

 

 

 

Environmental Protection Features

 

 

 

The PE sheath provides strong protection against environmental factors such as moisture, UV radiation, and chemicals, ensuring long-lasting durability and minimal maintenance requirements.

 

 

 


3. Standards Compliance and Certifications

 

 

3.1 International Standards

 

 

 

Standard Details
DIN VDE 0271 Compliance with cable construction guidelines
DIN VDE 0276-603 Power cable specifications for fire resistance
IEC 60502-1 Power cables with extruded insulation
DIN EN 50575 Fire performance standards

 

 

 

 

 

Compliance with International Standards

 

 

The Feichun PROTOTHEN X (N)A2XS(F)2Y cable meets international standards such as DIN VDE 0271, IEC 60502-1, and DIN EN 50575, ensuring that it is a high-quality, safe, and reliable solution for power distribution in railway systems.

 

 

 

These standards cover critical aspects such as fire performance, electrical safety, and environmental protection, making this cable a top choice for use in high-demand railway applications.

 

 

 

 

3.2 Performance Classifications

 

 

 

Performance Factor Details
CPR Reaction to Fire Fca classification for limited flame spread
Mechanical Strength Rating Suitable for high tensile applications
Environmental Protection Level Resistant to water, UV, and chemicals

 

 

 

 

The Fca classification ensures that the cable’s fire performance meets stringent European safety standards, limiting flame spread and smoke emissions. This makes it ideal for use in sensitive railway environments, such as underground tunnels.

 

 

 


4. Installation Guidelines

 

 

4.1 Installation Methods

 

 

 

Installation Method Recommended Techniques
Underground Use appropriate protection against mechanical damage
Tube Installation Follow correct installation protocols to prevent damage
Free Air Ensure proper cable support and bending radius
Indoor Ensure temperature and environmental controls
Underwater Follow watertight sealing methods for submerged installations

 

 

 

 

Installation Parameters

 

 

  • Minimum Bending Radius: 15 x D (where D is the overall cable diameter)

 

 

  • Temperature Range: -20°C minimum for installation

 

 

  • Permanent Tensile Strength: 30 N/mm²

 

 

  • Pull Force Calculations: Ensure proper pulling techniques to avoid damage

 

 

Feichun PROTOTHEN X (N)A2XS(F)2Y Single Core Track Feeder Cable 1.8/3KV: Reliable Power Distribution for Modern Railway 3

 

 

 

 


5. Common Installation Challenges and Solutions

 

 

 

5.1 Environmental Challenges

 

 

 

 

Challenge Solution
Water Ingress Use longitudinal watertight screens to prevent water from entering the cable core
UV Exposure Rely on PE sheath for UV resistance
Temperature Fluctuations XLPE insulation provides high thermal stability
Chemical Exposure The PE sheath offers chemical resistance

 

 

5.2 Mechanical Challenges

 

 

 

Challenge Solution
Improper Pulling Techniques Use correct pull force and bending radius during installation
Bending Radius Violations Adhere to 15 x D bending radius requirement
Cable Support Install with proper cable supports to avoid strain

 

 

6. Testing and Maintenance

 

 

 

6.1 Pre-installation Testing

 

 

 

 

Test Type Purpose
Insulation Resistance Measurement Verify the quality of insulation before installation
Conductor Continuity Verification Ensure the continuity of electrical paths
Sheath Integrity Testing Confirm the cable sheath is intact and watertight

 

 

6.2 Post-installation Verification

 

 

 

Test Type Purpose
System Integration Testing Ensure the system functions correctly in the real-world environment
Performance Verification Validate the cable’s current-carrying and thermal performance
Maintenance Schedule Regular inspection to ensure optimal performance

 

 

Feichun PROTOTHEN X (N)A2XS(F)2Y Single Core Track Feeder Cable 1.8/3KV: Reliable Power Distribution for Modern Railway 4

 

7. Applications and Case Studies

 

 

 

7.1 Railway Applications

 

 

  • Track Feeder Systems: Feichun PROTOTHEN X (N)A2XS(F)2Y cable provides reliable power distribution across railway tracks, ensuring smooth operation.

 

 

  • Tunnel Installations: With water-blocking technology, the cable is perfect for use in railway tunnels.

 

 

  • Platform Distribution Systems: Supports platform power distribution with ease, ensuring continuous power supply to critical systems.

 

 

  • Signaling Power Supply: Essential for providing reliable power to railway signaling systems.

 

 

 

 


8. Troubleshooting Guide

 

 

Issue Solution
Screen Damage Inspect the copper screen for continuity
Water Ingress Ensure the watertight seal is intact
Mechanical Damage Check for kinks or bends in the cable

 

 

 

 

 


9. Conclusion

 

 

The Feichun PROTOTHEN X (N)A2XS(F)2Y Single Core Track Feeder Cable offers a highly reliable, durable, and versatile solution for railway power distribution systems.

 

 

 

 

Its advanced features, including longitudinal watertight screens, high-performance insulation, and compliance with international standards, make it an ideal choice for modern railway infrastructure. With proper installation and regular maintenance, this cable can provide long-term performance and reliability for track feeder systems, tunnel installations, and platform power supplies.

 

 

 


10. References

 

 

  • DIN VDE 0271: Cable construction standards

 

 

  • IEC 60502-1: Power cables with extruded insulation

 

  • DIN EN 50575: Fire performance standards

 

 

  • Installation Guides: Manufacturer’s recommended installation and maintenance practices

 

 

 


The Feichun PROTOTHEN X (N)A2XS(F)2Y cable is a cost-effective and technologically advanced solution for railway applications, combining high electrical performance, mechanical durability, and environmental resilience.

 

 

 

For more information, contact Feichun Cable for technical support and detailed installation guides.

 

 

 

 

 

 

 

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

 

 

 

 

 

 

 

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.