Product Details
Place of Origin: Hefei Anhui China
Brand Name: FeiChun™
Certification: VDE 0250 Part 814
Model Number: PROTOTHEN X (N)A2XS(F)2Y
Payment & Shipping Terms
Minimum Order Quantity: 200 Meter
Price: 10-50 USD per meter, price varies according to specifications
Packaging Details: Cable Reels or Packaging Bags
Delivery Time: 15-30 Work Day
Payment Terms: T/T, Western Union
Supply Ability: 18,000 meters per week
Outer Sheath Color: |
Black |
Abrasion Resistant: |
Yes |
Water Resistant: |
Yes |
Highly Reliable: |
Trustworthy In Critical Tasks |
Operating Temperature: |
-40°C To +90°C |
Reliable Transmission: |
Ensures Consistent Power Transmission |
Flexible Handling: |
Easy Handling In Dynamic Conditions |
Cable Type: |
ROTOTHEN X (N)A2XS(F)2Y |
Tailored For Handling: |
Enhances Material Handling Efficiency |
Outdoor Suitability: |
Suited For Outdoor Use |
Chemical Stability: |
Stable In Chemical Environments |
Resistant To Debris: |
Guards Against Mining Debris |
Outer Sheath Color: |
Black |
Abrasion Resistant: |
Yes |
Water Resistant: |
Yes |
Highly Reliable: |
Trustworthy In Critical Tasks |
Operating Temperature: |
-40°C To +90°C |
Reliable Transmission: |
Ensures Consistent Power Transmission |
Flexible Handling: |
Easy Handling In Dynamic Conditions |
Cable Type: |
ROTOTHEN X (N)A2XS(F)2Y |
Tailored For Handling: |
Enhances Material Handling Efficiency |
Outdoor Suitability: |
Suited For Outdoor Use |
Chemical Stability: |
Stable In Chemical Environments |
Resistant To Debris: |
Guards Against Mining Debris |
Railway systems require highly reliable, durable, and efficient power distribution networks to ensure smooth and safe operations. These systems support a range of functions, from powering trains to running signalling and platform systems.
A key component of any railway power distribution infrastructure is the track feeder cable, which carries electrical power to the railway tracks and other essential components.
In modern railway applications, power distribution cables must be capable of operating in various environments, from underground tunnels to exposed tracks in all weather conditions.
This is where the Feichun PROTOTHEN X (N)A2XS(F)2Y Single Core Track Feeder Cable steps in, providing a versatile, high-performance solution for power distribution.
Track feeder cables serve as the backbone of railway power systems, providing the necessary electrical current to railway tracks, signals, and power supply points.
These cables are responsible for ensuring trains have the power to operate efficiently, maintaining essential systems, and minimizing downtime due to power disruptions.
The Feichun PROTOTHEN X (N)A2XS(F)2Y cable features a 1.8/3kV nominal voltage rating, making it ideal for high-performance railway distribution systems.
This voltage rating allows the cable to handle the significant power requirements of modern railways while remaining flexible and reliable in a variety of environments.
Specification | Details |
---|---|
Conductor Material | Bare Aluminum, Round Stranded (RM) |
Conductor Type | Aluminum Stranded (RM) |
Conductivity | High conductivity, suitable for long-distance power transmission |
Flexibility | Provides flexibility for easy installation in various environments |
Tensile Strength | 30 N/mm² tensile strength |
The bare aluminum conductor offers high conductivity, enabling it to carry large amounts of electrical current with minimal losses.
This is essential for maintaining consistent power supply in railway systems, even over long distances. The conductor’s flexibility ensures ease of handling and installation in tight spaces and complex configurations.
Specification | Details |
---|---|
Insulation Material | Cross-linked Polyethylene (XLPE) |
Continuous Operating Temperature | 90°C |
Short Circuit Temperature | 250°C (short-circuit) |
Voltage Rating | 1.8/3 kV (nominal), 3.6 kV (maximum) |
XLPE insulation is renowned for its high thermal stability, chemical resistance, and durability. It can withstand extreme temperatures and provide excellent protection against mechanical stress, water, and contaminants.
This makes the Feichun PROTOTHEN X (N)A2XS(F)2Y cable ideal for harsh railway environments, ensuring reliable performance under both normal and extreme conditions.
The 90°C continuous operating temperature and 250°C short-circuit temperature ratings ensure that the cable can handle the high thermal stresses encountered in railway power distribution systems without compromising performance or safety.
Specification | Details |
---|---|
Screen Material | Copper Wire Screen |
Water Blocking Mechanism | Longitudinal Watertight Screen |
Counterhelix Tape | Applied to prevent water ingress and enhance screen integrity |
The copper wire screen provides electromagnetic shielding, reducing the risk of interference from external electrical sources. This is essential in railway systems where reliable data transmission and signal integrity are critical.
The longitudinal watertight screen prevents the ingress of water, ensuring that the cable continues to function even in wet conditions. This technology is especially beneficial for submerged installations, tunnels, and areas exposed to heavy moisture.
The screen in the Feichun PROTOTHEN X (N)A2XS(F)2Y cable also contributes to its current-carrying capacity, making it a robust choice for power distribution in environments where high electrical demands must be met.
Specification | Details |
---|---|
Sheath Material | Polyethylene (PE) |
UV Resistance | High UV resistance |
Moisture and Chemical Resistance | Designed to resist moisture and chemicals in harsh environments |
The outer sheath of the PROTOTHEN X (N)A2XS(F)2Y cable is made of polyethylene (PE), providing excellent weather resistance, UV protection, and chemical resistance.
This ensures the cable can withstand outdoor conditions, including exposure to UV rays and chemicals commonly found in railway environments.
The PE sheath provides strong protection against environmental factors such as moisture, UV radiation, and chemicals, ensuring long-lasting durability and minimal maintenance requirements.
Standard | Details |
---|---|
DIN VDE 0271 | Compliance with cable construction guidelines |
DIN VDE 0276-603 | Power cable specifications for fire resistance |
IEC 60502-1 | Power cables with extruded insulation |
DIN EN 50575 | Fire performance standards |
The Feichun PROTOTHEN X (N)A2XS(F)2Y cable meets international standards such as DIN VDE 0271, IEC 60502-1, and DIN EN 50575, ensuring that it is a high-quality, safe, and reliable solution for power distribution in railway systems.
These standards cover critical aspects such as fire performance, electrical safety, and environmental protection, making this cable a top choice for use in high-demand railway applications.
Performance Factor | Details |
---|---|
CPR Reaction to Fire | Fca classification for limited flame spread |
Mechanical Strength Rating | Suitable for high tensile applications |
Environmental Protection Level | Resistant to water, UV, and chemicals |
The Fca classification ensures that the cable’s fire performance meets stringent European safety standards, limiting flame spread and smoke emissions. This makes it ideal for use in sensitive railway environments, such as underground tunnels.
Installation Method | Recommended Techniques |
---|---|
Underground | Use appropriate protection against mechanical damage |
Tube Installation | Follow correct installation protocols to prevent damage |
Free Air | Ensure proper cable support and bending radius |
Indoor | Ensure temperature and environmental controls |
Underwater | Follow watertight sealing methods for submerged installations |
Challenge | Solution |
---|---|
Water Ingress | Use longitudinal watertight screens to prevent water from entering the cable core |
UV Exposure | Rely on PE sheath for UV resistance |
Temperature Fluctuations | XLPE insulation provides high thermal stability |
Chemical Exposure | The PE sheath offers chemical resistance |
Challenge | Solution |
---|---|
Improper Pulling Techniques | Use correct pull force and bending radius during installation |
Bending Radius Violations | Adhere to 15 x D bending radius requirement |
Cable Support | Install with proper cable supports to avoid strain |
Test Type | Purpose |
---|---|
Insulation Resistance Measurement | Verify the quality of insulation before installation |
Conductor Continuity Verification | Ensure the continuity of electrical paths |
Sheath Integrity Testing | Confirm the cable sheath is intact and watertight |
Test Type | Purpose |
---|---|
System Integration Testing | Ensure the system functions correctly in the real-world environment |
Performance Verification | Validate the cable’s current-carrying and thermal performance |
Maintenance Schedule | Regular inspection to ensure optimal performance |
Issue | Solution |
---|---|
Screen Damage | Inspect the copper screen for continuity |
Water Ingress | Ensure the watertight seal is intact |
Mechanical Damage | Check for kinks or bends in the cable |
The Feichun PROTOTHEN X (N)A2XS(F)2Y Single Core Track Feeder Cable offers a highly reliable, durable, and versatile solution for railway power distribution systems.
Its advanced features, including longitudinal watertight screens, high-performance insulation, and compliance with international standards, make it an ideal choice for modern railway infrastructure. With proper installation and regular maintenance, this cable can provide long-term performance and reliability for track feeder systems, tunnel installations, and platform power supplies.
The Feichun PROTOTHEN X (N)A2XS(F)2Y cable is a cost-effective and technologically advanced solution for railway applications, combining high electrical performance, mechanical durability, and environmental resilience.
For more information, contact Feichun Cable for technical support and detailed installation guides.
Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.