Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™ Mining

Certification: VDE 0250 Part 813

Model Number: Windflex Global LSOH EMC S-3GCSHXOEU

Payment & Shipping Terms

Minimum Order Quantity: 200 Meter

Price: 10-50 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 18,000 meters per week

Highlight:
Flexible:
Yes
Suitable For:
Underground Mining Applications
Uv Stability:
Stable Under UV Exposure
Water Resistant:
Yes
Tailored For Handling:
Enhances Material Handling Efficiency
Abrasion Resistance:
Resists Abrasion Damage
Outer Sheath Color:
Black
Conductor Material:
Copper
Temperature Rating:
-25°C To +60°C
Oil Resistant:
Yes
Easy Installation:
Flexible Installation
Extreme Conditions:
Thrives In Tough Conditions
Long Lifespan:
Extended Operational Life
Flexible Bending:
Bends Without Damage
Flexible:
Yes
Suitable For:
Underground Mining Applications
Uv Stability:
Stable Under UV Exposure
Water Resistant:
Yes
Tailored For Handling:
Enhances Material Handling Efficiency
Abrasion Resistance:
Resists Abrasion Damage
Outer Sheath Color:
Black
Conductor Material:
Copper
Temperature Rating:
-25°C To +60°C
Oil Resistant:
Yes
Easy Installation:
Flexible Installation
Extreme Conditions:
Thrives In Tough Conditions
Long Lifespan:
Extended Operational Life
Flexible Bending:
Bends Without Damage
Comprehensive Technical Guide: Feichun Windflex Global LSOH EMC S-3GCSHXOEU 1kV Wind Turbine Cables - Specifications, Applications, and Best Practices

Comprehensive Technical Guide: Feichun Windflex Global LSOH EMC S-3GCSHXOEU 1kV Wind Turbine Cables - Specifications, Applications, and Best Practices

 

 

The Feichun Windflex Global LSOH EMC S-3GCSHXOEU 1kV Wind Turbine Cable is a cutting-edge solution designed for modern wind turbines. This cable combines superior materials, advanced design, and meticulous manufacturing processes to meet the demanding requirements of wind energy applications.

 

 

Comprehensive Technical Guide: Feichun Windflex Global LSOH EMC S-3GCSHXOEU 1kV Wind Turbine Cables - Specifications, Applications, and Best Practices 0

 

 

 

It is specifically crafted for medium mechanical strain in flexible applications and fixed installations, offering excellent performance and durability.

 

 

 

In wind turbine systems, Electromagnetic Compatibility (EMC) is crucial to ensure smooth operations, prevent interference, and protect sensitive equipment.

 

 

 

Coupled with its Low Smoke Zero Halogen (LSOH) properties, this cable is a sustainable choice for minimizing environmental and health risks in fire scenarios.

 

 

 

 

Technical Specifications

 

 

Cable Construction

 

 

Conductor Design: Class 5 fine wire copper as per IEC 60228 for enhanced flexibility.

 

 

Insulation Material: High Flame Retardant (HFFR) compound, ensuring excellent thermal and electrical properties.

 

 

Screening: Tinned copper braided screening provides exceptional EMC shielding and mechanical robustness.

 

 

Outer Sheath: LSOH material for reduced smoke and halogen-free emissions.

 

 

Core Identification: Adheres to HD308 color coding and printed number markings for easy identification.

 

 

 

Feature Specification
Conductor Material Copper, fine wire (Class 5)
Insulation Material HFFR
Screen Construction Tinned copper braiding
Outer Sheath Material LSOH
Voltage Rating 0.6/1 (1.2) kV
Test Voltage 3.5 kV
Max Conductor Temperature 90°C (250°C for short circuit)
Operating Temperatures -40°C to 90°C

 

 

 

 

Performance Parameters

 

Voltage Rating: 0.6/1 (1.2) kV.

 

 

Temperature Ratings:

 

Continuous Operation: Up to 90°C.

 

Short Circuit: Up to 250°C.

 

Installation and Ambient: As low as -40°C.

 

 

EMC Shielding: Superior interference suppression with braided copper screening.

 

 

Mechanical Strength: Resists torsional stress (±100°/m) and tensile loads (15 N/mm²).

 

 

 

Safety and Environmental Features

 

 

Fire Performance

 

The Feichun Windflex Global Cable meets stringent fire safety standards, making it ideal for critical applications:

 

 

Fire retardant as per DIN EN 60332-1-2.

 

Low smoke emission according to DIN EN 61034-2.

 

Halogen-free characteristics per DIN EN 50267-2-2.

 

Reduced acid gas emissions, tested to IEC 60754-2.

 

 

 

Environmental Resistance

 

Chemical Resistance: Withstands oils, chemicals, and lubricants.

 

UV and Ozone Resistance: Durable in outdoor installations.

 

Weather Resistance: Designed for harsh environments, including wind turbine towers and nacelles.

 

 

 

Property Standard/Specification
Fire Retardancy DIN EN 60332-1-2
Smoke Emission DIN EN 61034-2
Halogen-Free DIN EN 50267-2-2
Acid Gas Emission IEC 60754-2
UV Resistance IEC 60811-404

 

 

 

 

Installation Guidelines

 

Mechanical Installation Parameters

 

 

 

Bending Radius:

 

Fixed Installation: 6 × cable diameter (D).

 

Flexible Operation: 10 × D.

 

 

Tensile Strength: Maximum 15 N/mm².

 

Torsional Stress: Capable of handling ±100°/m.

 

 

 

Installation Best Practices

 

Temperature Considerations: Ensure laying temperatures are above -40°C.

 

 

Pulling Techniques: Use appropriate tools to prevent damage during installation.

 

 

Screen Termination: Follow proper termination techniques to maintain EMC integrity.

 

 

Gland Installation: Use compatible EMC glands to ensure proper grounding.

 

 

 

 

Application-Specific Considerations

 

 

Wind Turbine Applications

 

 

Nacelle Installations: Compact and flexible for confined spaces.

 

 

Tower Installations: Durable for vertical runs and exposed conditions.

 

 

Control System Connections: EMC compliance ensures stable operations.

 

 

Power Transmission: Reliable for critical power flow within turbines.

 

 

System Integration

 

 

EMC Compatibility: Prevents interference with sensitive control electronics.

 

 

Grounding and Bonding: Meets electrical safety requirements.

 

 

Infrastructure Integration: Flexible design suits various wind turbine setups.

 

 

 

Common Installation Challenges and Solutions

 

 

EMC-Related Issues

 

 

Screen Continuity Problems: Addressed by proper terminations and EMC gland installations.

 

 

Interference Prevention: Tinned copper screening ensures effective shielding.

 

 

 

Mechanical Challenges

 

Confined Spaces: Class 5 conductor flexibility aids in tight installations.

 

 

 

Vibration Management: Enhanced design for stability under turbine vibrations.

 

 

 

Quality Assurance and Testing

 

Factory Testing

 

 

Voltage withstand tests at 3.5 kV.

 

Insulation and conductor resistance measurements.

 

EMC screening effectiveness.

 

 

 

Installation Testing

 

EMC Effectiveness: Confirmed post-installation.

 

Continuity Testing: Ensures phase and grounding integrity.

 

 

 

Test Method/Standard
Voltage Withstand 3.5 kV
Insulation Resistance IEC 60228
EMC Screening DIN EN 60811-403

 

 

 

Maintenance and Troubleshooting

 

Preventive Maintenance

 

Regular inspections for mechanical integrity and EMC effectiveness.

 

 

Check for environmental damage and wear.

 

 

 

Problem Resolution

 

Diagnostic Procedures: Identify and isolate faults quickly.

 

Repair Guidelines: Use proper tools and materials for repairs.

 

Emergency Protocols: Ensure downtime is minimized.

 

 

Standards Compliance

 

Construction Standards

 

DIN VDE 0250-1 and IEC 60228 ensure high-quality construction.

 

DIN EN 50525-3-21 for consistent performance.

 

 

Performance Standards

 

Environmental testing per DIN EN 60811-404.

 

Fire and EMC certifications.

 

 

 

 

 

Comprehensive Technical Guide: Feichun Windflex Global LSOH EMC S-3GCSHXOEU 1kV Wind Turbine Cables - Specifications, Applications, and Best Practices 1

 

 

Technical Appendices

 

 

 

Reference Tables

 

 

Parameter Value
Current Carrying Capacity Refer to VDE 0298-4
Voltage Drop Calculations available
Correction Factors Based on installation

 

 

 

 

This comprehensive guide equips readers with essential knowledge about the Feichun Windflex Global LSOH EMC S-3GCSHXOEU 1kV Wind Turbine Cable, its features, and its advantages.

 

 

 

Designed to meet the challenges of wind energy systems, it delivers reliability, safety, and environmental compatibility, setting a benchmark in the industry.

 

 

 

 

 

 

 

 

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

 

 

 

 

 

 

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.