Send Message
products
products
Home > products > Mining Trailing Cable > Feichun PROTOMONT Type 506, Type 512, Type 518, Type 524 Auxiliary Cables with Galvanized Steel Pliable Wire Armoring

Feichun PROTOMONT Type 506, Type 512, Type 518, Type 524 Auxiliary Cables with Galvanized Steel Pliable Wire Armoring

Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: BS 6708

Model Number: PROTOMONT Type 506, Type 512, Type 518, Type 524

Payment & Shipping Terms

Minimum Order Quantity: 800 Meter

Price: 10-50 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 18,000 meters per week

Highlight:
Flexibility:
Extra Flexible
High Voltage Capacity:
Voltage Resilience For Mining
Sheath Material:
PCP
Application:
Underground Mining Equipment
Armour Type:
Steel Wire Armour
Flexible:
Yes
Flexible Handling:
Easy Handling In Dynamic Conditions
Weather Resistance:
Resilient In Diverse Weather
Suitable For:
Underground Mining Applications
Heat Tolerance:
Withstands High Temperatures
Temperature Rating:
-40°C To 90°C
Highly Reliable:
Trustworthy In Critical Tasks
Flexibility:
Extra Flexible
High Voltage Capacity:
Voltage Resilience For Mining
Sheath Material:
PCP
Application:
Underground Mining Equipment
Armour Type:
Steel Wire Armour
Flexible:
Yes
Flexible Handling:
Easy Handling In Dynamic Conditions
Weather Resistance:
Resilient In Diverse Weather
Suitable For:
Underground Mining Applications
Heat Tolerance:
Withstands High Temperatures
Temperature Rating:
-40°C To 90°C
Highly Reliable:
Trustworthy In Critical Tasks
Feichun PROTOMONT Type 506, Type 512, Type 518, Type 524 Auxiliary Cables with Galvanized Steel Pliable Wire Armoring

Feichun PROTOMONT Type 506, Type 512, Type 518, Type 524 Auxiliary Cables with Galvanized Steel Pliable Wire Armoring

 

Specialized Auxiliary Cables for Advanced Underground Mining Communication and Control Systems

 

 

Feichun PROTOMONT cables are engineered for underground mining environments, providing reliable solutions for communication and control systems.

 

Feichun PROTOMONT Type 506, Type 512, Type 518, Type 524 Auxiliary Cables with Galvanized Steel Pliable Wire Armoring 0

 

 

The Type 506, Type 512, Type 518, and Type 524 cables are designed to meet the most demanding requirements of modern mining infrastructure.

 

 

 

With high flexibility, robust protection, and outstanding environmental resistance, these cables are the go-to solution for mining operations globally.

 

 

 

I. Product Series Overview

 

 

Brand: Feichun PROTOMONT
Product Range: Type 506, Type 512, Type 518, Type 524
Compliance Standard: British Standard BS 6708
Primary Application: Underground mining remote control and interconnection circuits

 

 

 

Feichun’s PROTOMONT auxiliary cables are built for critical communication and control tasks in the mining industry.

 

 

 

They are designed to ensure safe and efficient operation of complex machinery in hazardous underground conditions, offering custom configurations for various mining needs.

 

 

 


II. Technical Specification Highlights

 

 

The PROTOMONT series cables feature a range of specifications tailored for underground mining operations, where performance and durability are non-negotiable. Let’s break down the technical details that make these cables a reliable choice for mining professionals.

 

 

 

A. Electrical Characteristics

 

 

Specification Details
Rated Voltage 320/550 V
Maximum AC Operating Voltage 0.45/0.60 kV
Maximum DC Operating Voltage 0.35/0.60 kV
AC Test Voltage 2 kV

 

 

 

 

These cables are designed to handle a variety of voltage scenarios in mining operations, ensuring stable power distribution and signal transmission even in extreme environments.

 

 

B. Conductor Construction

 

 

Specification Details
Material Tinned copper (Class 5, BS 6360)
Core Configuration Type 506: 6 cores
Type 512: 12 cores
Type 518: 18 cores
Type 524: 24 cores
Core Arrangement Laid up around a rubber filler
Insulation ETFE (Ethylene Tetrafluoroethylene)
Color Coding According to BS 7655

 

 

 

 

The use of finely-stranded tinned copper ensures excellent conductivity and long-lasting performance.

 

 

 

The ETFE insulation provides outstanding electrical and mechanical protection, ensuring that the cable maintains its integrity even under the most demanding conditions.

 

 

 

C. Sheathing and Protection

 

 

Specification Details
Inner Sheath CR (Chloroprene Rubber) in Black
Screening Individual copper/textile braid for each core
Reinforcement Flexible galvanized steel wire armoring
Outer Sheath PROTOFIRM CR in Black

 

 

 

 

The galvanized steel wire armoring is particularly important in mining applications, where physical stress, abrasion, and impact are constant challenges.

 

 

The outer PROTOFIRM CR sheath further protects the cable from harsh environmental factors like moisture, chemicals, and physical damage.

 

 

 


III. Performance Capabilities

 

 

Feichun PROTOMONT cables are built to excel in a variety of underground mining environments, ensuring that communication and control systems remain reliable throughout the operational lifecycle.

 

 

 

A. Environmental Resistance

 

 

Specification Details
Fire Resistance EN 60322-1-2 and IEC 60322-1-2 compliant
Oil Resistance EN 60811-404 and IEC 60811-404 compliant
Weather Resistance Unrestricted indoor and outdoor use
  Resistant to ozone and moisture

 

 

 

 

These cables are designed for maximum durability in harsh mining environments.

 

 

 

Whether exposed to high temperatures, chemicals, or harsh weather conditions, they maintain excellent performance, meeting fire and oil resistance standards.

 

 

B. Temperature Performance

 

 

Specification Details
Maximum Conductor Temperature 90°C
Short Circuit Conductor Temperature 250°C
Operating Temperature Ranges Fixed Installation: -40°C to +80°C
Fully Flexible: -25°C to +60°C

 

 

 

 

These cables can handle extreme temperatures, making them suitable for both fixed installations and flexible operation in high-temperature zones.

 

 


IV. Specialized Application Considerations

 

 

Underground mining operations present unique challenges that Feichun PROTOMONT cables are specifically designed to address.

 

 

A. Underground Mining Communication Challenges

 

  • Complex Machine Interconnection: Mining operations often require multiple control systems working together. With varying numbers of cores (from 6 to 24), Feichun cables can meet the specific needs of complex setups.

 

  • Extreme Environmental Conditions: Mining environments are tough—temperature fluctuations, moisture, chemicals, and mechanical wear. Feichun’s cables are built to withstand these challenges.

 

  • Reliable Remote Control Circuits: Feichun cables ensure that remote control signals are transmitted reliably, reducing the risk of operational downtime due to communication failure.

 

  • Minimizing Electrical Interference: The screening in these cables reduces electrical noise and ensures that sensitive equipment receives accurate control signals.

 

 

B. Unique Design Advantages

 

 

Feichun cables offer a range of unique advantages:

 

 

  • Flexible Core Configuration Options: Choose the right number of cores for your control system. From basic machine control (Type 506) to complex machinery interconnection (Type 524), you have the flexibility to select the perfect cable for your needs.

 

  • Robust Mechanical Protection: The galvanized steel armoring provides outstanding resistance to mechanical damage, making these cables ideal for tough mining conditions.

 

  • High-Temperature Tolerance: With a maximum conductor temperature of 90°C and short-circuit temperature of 250°C, these cables are capable of handling high-heat environments.

 

  • Comprehensive Electrical Insulation: With ETFE insulation, these cables offer superior electrical protection, ensuring safety and reliability.

 

Feichun PROTOMONT Type 506, Type 512, Type 518, Type 524 Auxiliary Cables with Galvanized Steel Pliable Wire Armoring 1

 

 

 


V. Detailed Core Configuration Analysis

 

 

 

A. Type 506 (6-Core Cable)

 

 

  • Ideal For: Simple machine control systems

 

  • Typical Applications: Basic remote operation circuits

 

 

This type is perfect for systems that require fewer cores, providing simplicity and flexibility for basic mining machinery operations.

 

 

 


 

 

B. Type 512 (12-Core Cable)

 

 

  • Suitable For: Intermediate complexity control systems

 

  • Enhanced Interconnection Capabilities: Allows for more intricate machinery control and interconnection

 

 

Ideal for moderate complexity systems, this cable offers a good balance of flexibility and interconnection capacity for medium-scale operations.

 

 

 


 

C. Type 518 (18-Core Cable)

 

 

  • Designed For: Complex machinery with multiple control points

 

  • Advanced Communication Requirements: For systems that require real-time data transmission across several components

 

 

This type of cable is well-suited for larger machines that need sophisticated interconnections.

 

 


 

D. Type 524 (24-Core Cable)

 

 

 

  • Optimal For: Highly sophisticated mining equipment

 

  • Maximum Flexibility in Circuit Design: This cable supports up to 24 cores, offering maximum flexibility for large, complex mining operations

 

 

With 24 cores, Type 524 offers the ultimate in versatility for the most demanding mining equipment.

 

 

 


Feichun PROTOMONT Type 506, Type 512, Type 518, Type 524 Auxiliary Cables with Galvanized Steel Pliable Wire Armoring 2

 

VI. Installation and Maintenance Guidelines

 

 

Proper installation and regular maintenance are key to ensuring that your Feichun PROTOMONT cables deliver optimal performance.

 

 

 

A. Proper Cable Routing and Support

 

 

  • Always follow the manufacturer's guidelines for cable routing to minimize strain and prevent damage.

 

 

  • Use cable trays, conduits, or other support systems to maintain cable integrity.

 

 

 

B. Regular Electrical and Mechanical Inspections

 

 

  • Inspect cables regularly for signs of wear, especially in high-stress areas.

 

  • Conduct routine electrical tests to check for any insulation damage or signs of electrical faults.

 

 

C. Adhering to Manufacturer's Bending Radius Guidelines

 

 

  • Avoid damaging the internal structure of the cable by adhering to the recommended bending radius.

 

 

D. Protection Against Mechanical and Environmental Stress

 

 

  • Additional protection in areas of high mechanical stress is essential for ensuring the longevity of the cable.

 

 

  • Monitor environmental conditions to avoid exposure to factors that could degrade the cable’s performance.

 

 


VII. Compliance and Certification

 

 

Feichun cables meet international standards, ensuring that they are safe and reliable for use in underground mining operations worldwide.

 

 

 

  • Compliance with British Standard BS 6708: This ensures that these cables meet rigorous safety and performance standards.

 

 

  • International Electrical and Safety Standards: Feichun cables are engineered to meet global standards, making them suitable for mining operations in countries such as Australia, South Africa, and the United States.

 

 

Feichun PROTOMONT Type 506, Type 512, Type 518, Type 524 Auxiliary Cables with Galvanized Steel Pliable Wire Armoring 3

 

 

 


VIII. Selection Criteria for Mining Engineers

 

 

When selecting cables for your mining operation, consider the following:

 

 

A. Critical Considerations

 

 

  • Specific Machine Control Requirements: Determine whether you need a basic control system or something more complex.

 

 

  • Number of Control Circuits Needed: Choose the cable with the appropriate number of cores based on your control system complexity.

 

 

  • Environmental Operating Conditions: Choose cables that can withstand the temperature, humidity, and mechanical stresses of your mining site.

 

 

  • Mechanical Stress Expectations: Consider the level of physical strain the cable will endure.

 

 

B. Comparative Advantages

 

 

  • Modular Core Configuration: Choose from flexible core options that meet your system's needs.

 

  • Superior Electrical Insulation: The ETFE insulation ensures safety and reliability.

 

  • Robust Mechanical Protection: The galvanized steel wire armoring is built to protect the cable from mechanical damage.

 

  • Wide Temperature Tolerance: With a wide temperature range, these cables can be used in various mining environments.

 

 


 

Feichun PROTOMONT Type 506, Type 512, Type 518, Type 524 Auxiliary Cables with Galvanized Steel Pliable Wire Armoring 4

 

 

 

 

The Feichun PROTOMONT Type 506/512/518/524 series offers a comprehensive solution for underground mining communication and control systems. These cables are engineered to provide high flexibility, robust protection, and exceptional performance in harsh underground environments.

 

 

 

With multiple core configurations, environmental resistance, and superior mechanical protection, these cables are built to meet the most demanding needs of modern mining infrastructure.

 

 

 

Key Differentiators:

 

  • Customizable core configurations

 

  • Extreme environment resilience

 

  • Advanced electrical and mechanical protection

 

  • Compliance with British Standard BS 6708

 

 

 

Whether you're operating in the depths of an underground mine or working with complex machinery, Feichun's auxiliary cables provide the reliability and performance you need for a safe and efficient operation.

 

 

 

 

 

 

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

 

 

 

 

 

 

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.