Send Message
products
products
Home > products > DIN VDE 0168 Mining Cable > Feichun PROTOMONT EMV-FC (N)SSHCOEU 0.6/1kV (-45°C) Frequency Converter Cables: Specialized Solutions for Opencast Mining

Feichun PROTOMONT EMV-FC (N)SSHCOEU 0.6/1kV (-45°C) Frequency Converter Cables: Specialized Solutions for Opencast Mining

Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: VDE 0250 Part 814

Model Number: PROTOMONT EMV-FC (N)SSHCOEU

Payment & Shipping Terms

Minimum Order Quantity: 800 Meter

Price: 10-60 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 16,000 meters per week

Highlight:

Opencast Mining Frequency Converter Cables

,

0.6/1kV Frequency Converter Cables

Standards:
RoHS Compliant
High Voltage Capacity:
Voltage Resilience For Mining
Robust Construction:
Durable Design For Harsh Environments
Cable Type:
Flexible
Flexible:
Yes
Reliable Performance:
Ensures A Long Operational Life
Flexible Mobility:
High Flexibility For Dynamic Operations
Type:
NSHTÖU Mining Reeling Cable
Temperature Rating:
-25°C To +60°C
Chemical Resilience:
Resistant To Common Mining Chemicals
Grounding Features:
Includes Grounding For Added Safety
Tailored For Handling:
Enhances Material Handling Efficiency
Heat Tolerance:
Withstands High Temperatures
Jacket:
Special Material
Standards:
RoHS Compliant
High Voltage Capacity:
Voltage Resilience For Mining
Robust Construction:
Durable Design For Harsh Environments
Cable Type:
Flexible
Flexible:
Yes
Reliable Performance:
Ensures A Long Operational Life
Flexible Mobility:
High Flexibility For Dynamic Operations
Type:
NSHTÖU Mining Reeling Cable
Temperature Rating:
-25°C To +60°C
Chemical Resilience:
Resistant To Common Mining Chemicals
Grounding Features:
Includes Grounding For Added Safety
Tailored For Handling:
Enhances Material Handling Efficiency
Heat Tolerance:
Withstands High Temperatures
Jacket:
Special Material
Feichun PROTOMONT EMV-FC (N)SSHCOEU 0.6/1kV (-45°C) Frequency Converter Cables: Specialized Solutions for Opencast Mining

Feichun PROTOMONT EMV-FC (N)SSHCOEU 0.6/1kV (-45°C) Frequency Converter Cables: Specialized Solutions for Opencast Mining

 

 

The Feichun PROTOMONT EMV-FC (N)SSHCOEU 0.6/1kV (-45°C) cables are advanced solutions for powering frequency converter-controlled drives in demanding applications.

 

 

 

Feichun PROTOMONT EMV-FC (N)SSHCOEU 0.6/1kV (-45°C) Frequency Converter Cables: Specialized Solutions for Opencast Mining 0

 

 

 

Designed for fixed installations and flexible operations, they excel in challenging opencast mining environments, construction sites, and industrial settings requiring high mechanical resilience.

 

 

 

These cables are also engineered for use in water up to 10 meters deep, in both fresh and saltwater conditions, making them versatile across various industrial scenarios.

 

 

 

Their robust construction and compliance with global standards ensure long-lasting performance and unmatched reliability.

 

 


Global Data

 

 

 

 

Attribute Detail
Brand PROTOMONT EMV-FC (N)SSHCOEU
Standard Compliance Based on DIN VDE 0250 part 812
Certifications/Approvals MSHA P-189-3, Fire Certificate of Russian Federation, TR-Certificate, GOST K, GOST B

 

 

 

 


 

 

Key Design Features

 

 

 

 

Component Specification
Conductor Finely stranded, tinned copper (Class 5)
Insulation PROTOLON EPR, Compound type: 3GI3
Core Identification Natural coloring with black numbering
Core Arrangement Three power cores, protective earth conductors split into outer interstices
Screen EMC-optimized concentric braid of tinned copper wires
Inner Sheath Vulcanized rubber compound, EPR GM1B
Outer Sheath PROTOFIRM, Synthetic elastomer compound (CR), Yellow

 

 

Notable Advantages

 

 

  • Tinned Copper Conductors: Provide superior flexibility and corrosion resistance.

 

 

  • EMC Shielding: Optimized for reduced electromagnetic interference, ensuring signal integrity.

 

 

  • Outer Sheath Durability: Highly resistant to environmental wear, chemicals, and mechanical stresses.

 

 


Electrical Parameters

 

 

Parameter Value
Rated Voltage 0.6/1 kV, also allowed for 640/1140 V
Max. Operating Voltage (AC) 0.7/1.2 kV
Max. Operating Voltage (DC) 0.9/1.8 kV
AC Test Voltage 5 kV

 

 

 

 

The cables are designed to handle high electrical loads efficiently while maintaining stable power transmission under challenging conditions.

 

 


Chemical Parameters

 

 

Property Performance
Fire Resistance EN 60332-1-2, IEC 60332-1-2
Oil Resistance Complies with EN 60811-404, IEC 60811-404
Weather Resistance Unrestricted use outdoors; resistant to ozone and moisture

 

 

 

These features ensure that the PROTOMONT EMV-FC cables maintain functionality in corrosive, humid, or high-temperature environments.

 

 

 

Feichun PROTOMONT EMV-FC (N)SSHCOEU 0.6/1kV (-45°C) Frequency Converter Cables: Specialized Solutions for Opencast Mining 1

 

 

 

 


Thermal Parameters

 

 

 

Condition Temperature Range
Max. Conductor Temperature 90 °C
Short-Circuit Conductor Temp 250 °C
Ambient Temp (Fixed) -40 °C to 80 °C
Ambient Temp (Flexible) -25 °C to 60 °C

 

 

 

 

 

 

 

The cables’ wide temperature tolerance ensures safe and reliable operation in both extreme cold and hot environments.

 

 


Mechanical Parameters

 

 

Parameter Specification
Tensile Load Max. 15 N/mm²
Torsional Stress 25 °/m
Minimum Bending Radius As per DIN VDE 0298 part 3

 

 

 

 

These cables are built to withstand repetitive motion, high stress, and extreme mechanical loads, making them ideal for mobile mining and industrial machinery.

 

 


Problems This Cable Solves

 

Electromagnetic Interference (EMI): The EMC-optimized screen ensures clean signal transmission by minimizing EMI.

 

 

 

Durability in Harsh Conditions: Resistant to fire, oil, and chemicals, the cables perform reliably in rugged terrains and corrosive environments.

 

 

 

Mechanical Stress: Designed to endure heavy loads, torsional movements, and repeated bending without degradation.

 

 

 

Flexibility in Extreme Cold: Operates seamlessly at temperatures as low as -45°C, addressing the needs of mining operations in cold climates.

 

 

 

 


Installation Tips and Best Practices

 

 

 

Cable Management: Use appropriate clamps and supports to avoid mechanical stress at bending points.

 

 

 

Avoid Sharp Bends: Ensure compliance with the minimum bending radius during installation.

 

 

 

Regular Inspections: Schedule periodic visual and electrical inspections to identify wear and maintain optimal performance.

 

 

 

Waterproofing Measures: Use sealed connectors and appropriate fittings for submersion applications.

 

 

 

By adhering to these guidelines, you can maximize the lifespan and performance of the PROTOMONT EMV-FC cables.

 

 


Comparative Advantages

 

 

Feature PROTOMONT EMV-FC Cables Standard Cables
Temperature Range Operates up to -45°C Typically limited to -25°C
EMC Shielding Optimized concentric braid Basic shielding
Chemical Resistance High resistance to oils, ozone, and moisture Moderate resistance
Flexibility Highly flexible for dynamic operations Limited flexibility in harsh conditions

 

 

 


Use Cases in Opencast Mining

 

 

  • Frequency Converter Drives: Reliable power for motors with variable-speed controls.

 

 

  • Submersible Pumps: Withstands water ingress and saline environments.

 

 

  • Heavy Machinery: Facilitates safe and efficient power transmission in mobile mining equipment.

 

 

 


Conclusion

 

 

The Feichun PROTOMONT EMV-FC (N)SSHCOEU 0.6/1kV (-45°C) cables are engineered for high-stakes applications in opencast mining, heavy industry, and extreme environmental conditions.

 

 

With robust materials, advanced EMC shielding, and exceptional temperature tolerance, these cables deliver reliable performance, safety, and longevity.

 

 

 

 

 

 

 

 

 

 

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

 

 

 

 

 

 

 

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.