Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: VDE 0250 Part 814

Model Number: PROTOMONT (M) (N)SHOEU

Payment & Shipping Terms

Minimum Order Quantity: 200 Meter

Price: 10-30 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 18,000 meters per week

Highlight:

Opencast Mining Electrical Systems Cables

,

0.6/1kV Cables

,

Feichun PROTOMONT Cables

Color:
Black
High Voltage Capacity:
Voltage Resilience For Mining
Tensile Strength:
30kN
Rated Voltage:
600V
Armor Material:
Galvanized Steel
Versatile Compatibility:
Fits Various Equipment Configurations
Custom Power Solutions:
Tailored For Equipment Needs
Resistant To Debris:
Guards Against Mining Debris
Voltage:
600V / 1000V
Durable Construction:
Long-lasting In Demanding Conditions
Shielding Material:
Tinned Copper Braid
Maximum Tensile Strength:
20kN
Armoring Material:
Galvanized Steel Wires
Reliable Performance:
Ensures A Long Operational Life
Color:
Black
High Voltage Capacity:
Voltage Resilience For Mining
Tensile Strength:
30kN
Rated Voltage:
600V
Armor Material:
Galvanized Steel
Versatile Compatibility:
Fits Various Equipment Configurations
Custom Power Solutions:
Tailored For Equipment Needs
Resistant To Debris:
Guards Against Mining Debris
Voltage:
600V / 1000V
Durable Construction:
Long-lasting In Demanding Conditions
Shielding Material:
Tinned Copper Braid
Maximum Tensile Strength:
20kN
Armoring Material:
Galvanized Steel Wires
Reliable Performance:
Ensures A Long Operational Life
Feichun PROTOMONT (M) (N)SHOEU 0.6/1kV Cables Advanced Solutions for Opencast Mining Electrical Systems

Feichun PROTOMONT (M) (N)SHOEU 0.6/1kV Cables: Advanced Solutions for Opencast Mining Electrical Systems

 

 

 

The Feichun PROTOMONT (M) (N)SHOEU 0.6/1kV cables are designed to revolutionize electrical systems in demanding opencast mining environments. These cables boast unmatched durability, flexibility, and reliability, specifically tailored for dynamic and challenging industrial conditions.

 

 

 

 

 

Engineered with advanced materials and precision manufacturing techniques, they provide long-lasting performance even under extreme operational stresses.

 

Feichun PROTOMONT (M) (N)SHOEU 0.6/1kV Cables Advanced Solutions for Opencast Mining Electrical Systems 0

 

 

 


Product Overview

 

 

Key Technical Specifications

 

 

 

Parameter Specification
Rated Voltage 450/750 V (control cables)
  0.6/1 kV (power cables)
Maximum Operating Voltage (AC) 0.7/1.2 kV
Maximum Operating Voltage (DC) 0.9/1.8 kV
AC Test Voltage 3 kV (power cables)
  2 kV (control cables)
Temperature Range Fixed: -40°C to 80°C
  Fully flexible: -25°C to 60°C
Conductor Material Electrolytic copper, finely stranded (Class 5)
Insulation Material PROTOLON EPR

 

 

 

Design Features

 

  • Conductor: Electrolytic copper, finely stranded for enhanced flexibility and electrical conductivity.

 

  • Insulation: Ethylene Propylene Rubber (EPR), ensuring exceptional dielectric strength and environmental resistance.

 

  • Core Identification: Light gray insulation with black numerical markings, enabling easy identification during installation.

 

  • Sheathing: Inner sheath made of special EPR compound, with an outer sheath of black chlorinated rubber (5GM3) for maximum protection.

 

 


Operational Capabilities

 

 

Environmental Resistance

 

 

Environmental Factor Performance
Temperature Tolerance Operates between -40°C and 80°C
Water Resistance Submersible up to 500 meters
Ozone and UV Resistance Fully resistant to degradation
Oil Resistance Complies with EN 60811-404

 

 

 

 

Mechanical Performance

 

 

Mechanical Parameter Specification
Rewinding Speed Up to 100 m/min
Tensile Load on Conductor Up to 15 N/mm²
Torsional Stress Up to 100° per meter
Bending Radius Meets DIN VDE 0298 part 3 standards

 

 

 

 


 

 

Specialized Applications

 

 

The PROTOMONT (M) (N)SHOEU cables excel in diverse opencast mining and industrial environments.

 

 

 

Primary Use Cases

 

 

  • Conveyor Belt Electrical Systems: Provides stable power and control for continuous belt operations.

 

  • Movable Equipment Installations: Designed to handle repetitive movement without compromising performance.

 

  • Submersible Pump Connections: Reliable in deep-water applications up to 500 meters.

 

  • Interconnected Mobile Units: Facilitates safe and efficient energy transfer between machinery.

 

Feichun PROTOMONT (M) (N)SHOEU 0.6/1kV Cables Advanced Solutions for Opencast Mining Electrical Systems 1

 

 

 

Deployment in Harsh Conditions

 

 

  • Temperature Extremes: Withstands both freezing and high-temperature conditions without degradation.

 

 

  • High-Stress Motion: Retains flexibility and durability under constant bending, twisting, and pulling.

 

 

 


Compliance and Certifications

 

 

Certification/Standard Details
Russian Federation Fire Certificate Certified for safety in hazardous environments.
TR-Zertifikat Ensures performance reliability in extreme applications.
GOST K and GOST B Meets stringent Russian industrial standards.
DIN VDE 0250 Part 812 Fully compliant with international cable standards.

 

 

 

 


Unique Selling Points

 

 

Problems Solved

 

 

  • Mechanical Stress Tolerance: Withstands high tension, torsion, and dynamic movement in demanding operations.

 

  • Environmental Durability: Resists water ingress, oil, UV, ozone, and extreme temperatures.

 

  • Electrical Reliability: Maintains consistent power delivery and signal transmission even under varying load conditions.

 

 

 

Advantages of Materials and Manufacturing

 

 

  • Advanced Sheathing Materials: Chlorinated rubber and EPR compounds offer unmatched environmental resistance.

 

 

  • Flexible Conductor Design: The finely stranded Class 5 copper allows for superior flexibility and energy efficiency.

 

 

  • Rigorous Quality Testing: Each cable undergoes extensive testing to ensure long-term reliability and safety.

 

 


Feichun PROTOMONT (M) (N)SHOEU 0.6/1kV Cables Advanced Solutions for Opencast Mining Electrical Systems 2

 

 

Installation Considerations

 

 

Best Practices

 

 

Submersion Depth: Limit to 500 meters for optimal performance.

 

 

 

Cable Management: Use appropriate support systems to reduce mechanical strain.

 

 

 

Inspection Schedule: Regularly check for visible wear and electrical continuity.

 

 

 

 

Installation Environment: Avoid sharp bends and ensure compliance with bending radius specifications.

 

 

 

Tips for Extending Lifespan

 

 

  • Use protective conduits in areas of high abrasion.

 

  • Avoid exceeding tensile load and torsional stress limits.

 

  • Implement proper termination techniques to reduce strain on connectors.

 

 

 


Comparative Advantages

 

 

Feature Feichun PROTOMONT (M) (N)SHOEU Standard Mining Cables
Flexibility Superior, designed for dynamic environments Moderate
Environmental Resistance Ozone, water, UV, and oil resistant Limited
Operational Temperature -40°C to 80°C -20°C to 70°C
Service Life Extended due to advanced materials Standard

 

 

 

 


Conclusion

 

 

 

The Feichun PROTOMONT (M) (N)SHOEU 0.6/1kV cables redefine standards for electrical systems in opencast mining and industrial applications.

 

 

 

By integrating cutting-edge materials, innovative design, and robust safety features, they ensure unparalleled performance and durability in the harshest environments.

 

 

 

 

 

 

 

 

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

 

 

 

 

 

 

 

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.