Send Message
products
products
Home > products > Crane Festoon Cable > Feichun Advanced Screening Technology FESTOONFLEX C-PUR-HF D12YC11Y Screened Cable for Critical Industrial Applications

Feichun Advanced Screening Technology FESTOONFLEX C-PUR-HF D12YC11Y Screened Cable for Critical Industrial Applications

Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: VDE 0250 Part 814

Model Number: PUR-HF D12YC11Y

Payment & Shipping Terms

Minimum Order Quantity: 800 Meter

Price: 10-50 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 16,000 meters per week

Highlight:

Critical Industrial Applications Screened Cable

,

Feichun Advanced Screening Technology Cable

,

FESTOONFLEX C-PUR-HF D12YC11Y Screened Cable

Conductor Size:
14 AWG
Load Capacity:
10 Tons
Uv Resistant:
Yes
Oil Resistant:
Yes
Certifications:
UL, CSA, RoHS
Voltage:
600V
Weather Resistant:
Yes
Cable Flame Retardant:
IEC 60332-1/IEC 60332-3
Temperature Rating:
-40°C To 90°C
Oil Resistance:
Yes
Bending Radius:
10x Cable Diameter
Temperature Range:
-40°C To 105°C
Flame Retardant:
Yes
Durability:
Long-lasting
Conductor Size:
14 AWG
Load Capacity:
10 Tons
Uv Resistant:
Yes
Oil Resistant:
Yes
Certifications:
UL, CSA, RoHS
Voltage:
600V
Weather Resistant:
Yes
Cable Flame Retardant:
IEC 60332-1/IEC 60332-3
Temperature Rating:
-40°C To 90°C
Oil Resistance:
Yes
Bending Radius:
10x Cable Diameter
Temperature Range:
-40°C To 105°C
Flame Retardant:
Yes
Durability:
Long-lasting
Feichun Advanced Screening Technology FESTOONFLEX C-PUR-HF D12YC11Y Screened Cable for Critical Industrial Applications

Feichun Advanced Screening Technology: FESTOONFLEX C-PUR-HF D12YC11Y Screened Cable for Critical Industrial Applications

 

 

The FESTOONFLEX C-PUR-HF D12YC11Y is a cutting-edge solution for industrial applications that demand robust performance, reliability, and advanced electromagnetic interference (EMI) protection.

 

 

Feichun Advanced Screening Technology FESTOONFLEX C-PUR-HF D12YC11Y Screened Cable for Critical Industrial Applications 0

 

 

Engineered for the toughest environments, this cable combines innovative materials, superior screening technology, and compliance with international standards to ensure uninterrupted operations in critical industrial systems.

 

 


1. Product Positioning

 

 

1.1 Unique Design Characteristics

 

 

The FESTOONFLEX C-PUR-HF D12YC11Y stands out as a specialized screened cable that excels in festoon systems and environments where EMI protection is essential. With its flexible core design and halogen-free polyurethane sheath, it offers:

 

 

  • Enhanced durability for frequent movement in industrial operations.

 

  • Resistance to extreme environmental conditions, including high temperatures and mechanical stress.

 

  • Exceptional electromagnetic shielding to protect sensitive signals.

 

 

1.2 Core Technical Differentiators

 

 

This cable’s unique features include:

 

 

Feature Details
Voltage Rating 0.6/1 kV (600/1000V)
Screening Material Tinned copper wire braid
Core Configuration Flexible, twisted arrangement
Environmental Compliance Halogen-free, flame-retardant materials

 

 

 

 


2. Technical Specifications

 

 

2.1 Electrical Characteristics

 

 

Parameter Value
Rated Voltage 0.6/1 kV
Maximum AC Voltage 0.7/1.2 kV
Maximum DC Voltage 0.9/1.8 kV
AC Test Voltage 2.5 kV (5 Minutes)

 

 

 

 

The cable’s advanced screening technology reduces electrical noise, ensuring clean signal transmission and system stability.

 

 

 

2.2 Screening Performance

 

 

Feature Benefit
Tinned Copper Braid EMI protection and signal integrity
High Coverage Percentage Enhanced electrical noise immunity

 

 

 

 


Feichun Advanced Screening Technology FESTOONFLEX C-PUR-HF D12YC11Y Screened Cable for Critical Industrial Applications 1

 

 

3. Mechanical and Environmental Specifications

 

 

3.1 Mechanical Resilience

 

 

Parameter Value
Maximum Conductor Tensile Load 15 N/mm²
Minimum Bending Radius 6x Cable Diameter
Travel Speeds Festoon/Chain Systems: Up to 210 m/min

 

 

 

 

3.2 Temperature Performance

 

 

Condition Temperature Range
Fixed Installation -50°C to +80°C
Flexible Operation -40°C to +80°C
Maximum Conductor Temp. 90°C
Short Circuit Temp. 250°C

 

 

 

 


4. Detailed Configuration Options

 

 

4.1 Power Cable Variants

 

 

Core Configuration Range (mm²)
Single-Core 1x25 to 1x240
Four-Core 4x1.5 to 4x50
Five-Core 5x1.5 to 5x2.5

 

 

 

 

4.2 Control Cable Options

 

Variant Configuration
Screened Control Cables 7x1.5, 12x1.5, 18x1.5
Screened Pair Options Available

 

 

 


5. Key Technical Advantages

 

 

5.1 Electromagnetic Protection

 

 

The tinned copper wire braid effectively reduces EMI, ensuring stable performance in environments with high electrical noise. This feature is especially critical for sensitive control and communication systems.

 

 

 

 

5.2 Material Innovation

 

 

  • Halogen-Free Polyurethane Sheath: Environmentally friendly and flame retardant.

 

 

  • Durability: Exceptional resistance to abrasion, oils, and chemicals.

 

 

 

Material Property Advantage
Halogen-Free Low toxic emissions during fire
Flame Retardant Improved safety

 

 

 

 


 

6. Typical Application Domains

 

 

The FESTOONFLEX C-PUR-HF D12YC11Y excels in various industrial applications:

 

 

  • Automated Manufacturing Systems: Reliable operation in high-precision environments.

 

  • Material Handling Equipment: Seamless performance in overhead cranes and festoon systems.

 

  • Machine Tool Installations: Superior EMI protection ensures accurate operation.

 

  • Drag Line Operations: Handles frequent movement with ease.

 

 


Feichun Advanced Screening Technology FESTOONFLEX C-PUR-HF D12YC11Y Screened Cable for Critical Industrial Applications 2

 

 

7. Installation and Deployment Considerations

 

 

7.1 Best Practices

 

 

To maximize the cable’s lifespan:

 

 

  • Cable Routing: Follow proper routing paths to avoid strain.

 

  • Bending Radius: Maintain the recommended minimum bending radius of 6x cable diameter.

 

  • Regular Inspections: Periodically check for wear and tear.

 

 

7.2 Potential Operational Challenges

 

 

Challenge Mitigation Strategy
Chain System Overload Reduce travel speed
EMI Issues Conduct compatibility tests
Mechanical Strain Install protective guides

 

 

 


8. Compliance and Standards

 

 

The cable meets stringent industry standards, including:

 

 

 

Standard Purpose
DIN EN 60228 Conductor Flexibility
DIN VDE 0293-308 Core Identification
IEC 60332-1 Fire Performance

 

 

 

 

It is also suitable for underwater applications up to 50 meters, making it versatile for various industrial setups.

 

 


9. Performance Optimization Guidelines

 

 

Aspect Optimization Tip
Cross-Section Selection Match to current requirements
Ambient Temperature Factor in for performance
Electromagnetic Environment Use proper grounding techniques

 

 

 

 


Conclusion

 

 

The FESTOONFLEX C-PUR-HF D12YC11Y cable delivers unparalleled performance, advanced EMI protection, and exceptional durability for critical industrial applications. Its innovative design ensures reliability in even the most demanding environments.

 

 


Technical Support

 

 

Feichun offers expert consultation to help you choose the right cable for your specific needs. Contact our specialists to ensure the best performance and longevity for your industrial systems.

 

 

 

 

 

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

 

 

 

 

 

 

 

 

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.