Product Details
Place of Origin: Hefei Anhui China
Brand Name: FeiChun™ Mining
Certification: VDE 0250 Part 814
Model Number: NSHTOEU
Payment & Shipping Terms
Minimum Order Quantity: 800 Meter
Price: 10-30 USD per meter, price varies according to specifications
Packaging Details: Cable Reels or Packaging Bags
Delivery Time: 15-30 Work Day
Payment Terms: T/T, Western Union
Supply Ability: 18,000 meters per week
Size: |
16/25/35/50/70/95/120/150/185 |
Emi Shielding: |
Minimizes Electromagnetic Interference |
Shock Resistance: |
Resistant To Shocks |
Armor Material: |
Galvanized Steel |
Conductor Size: |
10 AWG |
Color: |
Black |
Number Of Cores: |
3+3+1 |
Usage: |
Mining Equipment |
Rated Temperature: |
105℃ |
Shielding: |
None |
Size: |
16/25/35/50/70/95/120/150/185 |
Emi Shielding: |
Minimizes Electromagnetic Interference |
Shock Resistance: |
Resistant To Shocks |
Armor Material: |
Galvanized Steel |
Conductor Size: |
10 AWG |
Color: |
Black |
Number Of Cores: |
3+3+1 |
Usage: |
Mining Equipment |
Rated Temperature: |
105℃ |
Shielding: |
None |
Mining operations in Schwarze Pumpe demand robust, high-performance solutions to address power transmission challenges in extreme environments.
The NSHTOEU High-Performance Power Cable is specifically engineered for these conditions, combining durability, flexibility, and exceptional resistance to mechanical and chemical stress.
Designed to handle extreme temperatures, high humidity, and electromagnetic interference, this cable ensures reliable operation, enhanced safety, and reduced maintenance downtime in deep mining applications.
Deep mining operations like those in Schwarze Pumpe present a unique set of challenges. The combination of extreme temperatures, mechanical stress, and exposure to corrosive chemicals demands specialized power transmission solutions.
Equipment downtime or failure caused by inadequate cabling can result in costly delays and increased safety risks.
Mining environments are inherently harsh, with numerous factors threatening the performance of conventional cables:
To address these challenges, Feichun introduces the NSHTOEU High-Performance Power Cable, meticulously designed for mining conditions.
Its advanced materials and manufacturing techniques ensure superior performance, safety, and longevity.
The NSHTOEU cable incorporates cutting-edge materials and engineering to thrive in mining environments:
Component | Material/Feature | Performance Advantage |
---|---|---|
Conductor | High-purity, multi-strand copper | Superior electrical conductivity and flexibility |
Insulation | Cross-linked polyethylene (XLPE) | High dielectric strength and temperature resistance |
Jacket | Polyurethane (PUR) | Exceptional abrasion and oil resistance |
Reinforcements | Kevlar fillers and braided armor | Enhanced mechanical protection against impacts |
Copper Conductor: Offers optimal current-carrying capacity, even under high loads.
XLPE Insulation: Resists thermal and electrical stress, ensuring consistent operation.
PUR Jacket: Shields the cable from external mechanical and chemical damage.
Armor Layer: Protects against physical impacts and compression in rugged conditions.
Characteristic | Specification |
---|---|
Temperature Range | -40°C to +90°C |
Voltage Rating | 1.8/3 kV |
Abrasion Resistance | High-grade polyurethane jacket |
Chemical Resistance | Resistant to oil, acids, and alkalis |
Flexibility | Designed for continuous movement |
Flame Retardancy | IEC 60332 compliant |
Electromagnetic Compatibility | Advanced EMI shielding |
Application | Purpose |
---|---|
Power transmission for equipment | Supplies power to conveyors, pumps, and fans |
Control and instrumentation | Enables monitoring and automation systems |
Emergency lighting systems | Ensures safety during power outages |
Communication systems | Maintains operational connectivity |
The NSHTOEU cable outperforms conventional options in key areas:
Test | Purpose |
---|---|
Flame Testing (IEC 60332) | Ensures fire resistance and self-extinguishing properties. |
Smoke and Toxicity Tests | Verifies low emissions for safe underground use. |
Impact Testing | Measures durability under mechanical stress. |
Flex Testing | Assesses performance under continuous movement. |
Chemical Resistance | Confirms resistance to oils, acids, and alkalis. |
The NSHTOEU cable meets global standards, ensuring safe and reliable operation:
Standard | Description |
---|---|
IEC 60332 | Fire retardancy and self-extinguishing tests |
DIN VDE 0250 | Cable specifications for heavy-duty applications |
ISO 9001:2015 | Quality management for consistent product output |
Challenge: Harsh environmental conditions led to frequent cable failures, causing downtime and increasing maintenance costs.
Solution: Implementing NSHTOEU cables improved reliability and reduced downtime.
Metric | Before NSHTOEU | After NSHTOEU |
---|---|---|
Downtime (hours/month) | 15 | 2 |
Cable Replacement Frequency | Every 6 months | Every 3 years |
Maintenance Costs | High | Reduced by 40% |
The NSHTOEU cable has proven its versatility in various mining operations, demonstrating adaptability and durability.
The NSHTOEU High-Performance Power Cable is the ultimate choice for Schwarze Pumpe mining operations.
With its robust construction, exceptional performance, and compliance with stringent standards, it ensures uninterrupted power transmission in the harshest environments.
For enhanced safety, reliability, and efficiency in mining, choose the NSHTOEU cable. Contact Feichun today for customized solutions tailored to your operational needs!
Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.