{"id":9991,"date":"2026-04-03T10:30:37","date_gmt":"2026-04-03T02:30:37","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=9991"},"modified":"2026-04-03T10:30:39","modified_gmt":"2026-04-03T02:30:39","slug":"nshtoeu-trommelflex-ksm-s","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/nshtoeu-trommelflex-ksm-s\/","title":{"rendered":"(N)SHTOEU Trommelflex\u00ae\u00a0KSM-S"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">0.6\/1 kV High-Performance Pure-Power Reeling Cable \u2014 8 Configurations from 3\u00d735+3\u00d716\/3 to 3\u00d7240+3\u00d7120\/3 with Triple-Split Protective Earth, 5GM5 Premium Neoprene, EPR 3GI3 Insulation, \u221240\u00b0C Dynamic Rating, 20 N\/mm\u00b2 Conductor Tensile, 180 m\/min, 4 kV Test Voltage, and EAC Eurasian Certification \u2014 All the KSM-S Performance Without Fiber Optics, for STS Crane Main Power, Stacker-Reclaimers, Ship Loaders, and Heavy Industrial Drum Reeling<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When You Need KSM-S Performance But Not Fiber Optics: The Same 5GM5 Sheath, Same \u221240\u00b0C Dynamic Rating, Same 20 N\/mm\u00b2 Tensile, Same 180 m\/min Speed \u2014 But With a Cleaner Triple-Split Earth Architecture (3\u00d7G\/3) That Provides Superior Fault Current Distribution and Mechanical Symmetry Compared to the Dual-Split (2\u00d7G\/2) Used in the FO Variant<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"c1bebb\" data-has-transparency=\"false\" style=\"--dominant-color: #c1bebb;\" loading=\"lazy\" decoding=\"async\" width=\"1059\" height=\"375\" sizes=\"auto, (max-width: 1059px) 100vw, 1059px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1126.avif\" alt=\"\" class=\"wp-image-9992 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1126.avif 1059w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1126-300x106.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1126-768x272.avif 768w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1126-400x142.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1126-800x283.avif 800w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1126-832x295.avif 832w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n<title>(N)SHTOEU Trommelflex\u00ae KSM-S 0.6\/1 kV High-Performance Power Reeling Cable: 8 Configurations 3\u00d735\u20133\u00d7240, Triple-Split Earth 3\u00d7G\/3, 5GM5 Neoprene, EPR 3GI3, \u221240\u00b0C Moving, 20 N\/mm\u00b2, 180 m\/min, 4 kV Test, Up to 540 A \/ 14,400 N, DIN VDE 0250-814, EAC Certified, for STS Cranes, Stacker-Reclaimers, Ship Loaders &#038; Heavy Industrial Reeling | FeiChun Cable<\/title>\n<meta name=\"description\" content=\"(N)SHTOEU Trommelflex\u00ae KSM-S 0.6\/1 kV high-performance power reeling cable per VDE 0250-814. 8 configurations from 3\u00d735+3\u00d716\/3 to 3\u00d7240+3\u00d7120\/3. Triple-split earth. 5GM5 neoprene. EPR 3GI3. \u221240\u00b0C moving. 20 N\/mm\u00b2. 180 m\/min. 4 kV test. Up to 540 A \/ 14,400 N. EAC certified. The pure-power KSM-S platform without fiber optics \u2014 for STS crane main power, stacker-reclaimers, ship loaders. Cost-effective Feichun alternative.\">\n<meta name=\"keywords\" content=\"NSHTOEU KSM-S, Trommelflex KSM-S, KSM-S cable, KSM-S reeling cable, high performance reeling cable, power reeling cable, 3x240 reeling cable, 3x185 reeling cable, 3x150 reeling cable, 3x120 reeling cable, 3x95 reeling cable, 3x70 reeling cable, 3x50 reeling cable, 3x35 reeling cable, triple split earth, 3xG3 earth conductor, 540 amp reeling cable, 461 amp cable, 404 amp cable, 352 amp cable, 301 amp cable, 250 amp cable, 14400N tensile, 11100N tensile, DIN VDE 0250-814, EPR 3GI3 insulation, 5GM5 neoprene, 5GM3 inner sheath, bare copper Class 5, minus 40 moving, 20 N mm2 tensile, 180 m per min, 4 kV test voltage, flame retardant IEC 60332, oil resistant EN 60811, black rubber cable, EAC certified cable, Eurasian conformity cable, STS crane main power, stacker reclaimer cable, ship loader cable, bucket wheel excavator cable, conveyor power cable, heavy industrial reeling, Prysmian TROMMELFLEX KSM, Prysmian CORDAFLEX SMK, Klaus Faber KSM-S, Feichun KSM-S, Feichun reeling cable, Chinese premium crane cable, port crane power cable, RTG power cable, RMG power cable, motorized drum power cable, split protective conductor, polyester braid torsion, plus minus 50 torsion\">\n<meta name=\"author\" content=\"Anhui Feichun Special Cable Co., Ltd.\">\n<meta name=\"robots\" content=\"index,follow\">\n<meta property=\"og:title\" content=\"(N)SHTOEU Trommelflex\u00ae KSM-S \u2014 The Pure-Power High-Performance Reeling Cable: 8 Configurations to 540 A \/ 14,400 N with 5GM5, EPR 3GI3, \u221240\u00b0C Moving, and Triple-Split Earth\">\n<meta property=\"og:type\" content=\"article\">\n<link rel=\"preconnect\" href=\"https:\/\/fonts.googleapis.com\">\n<link rel=\"preconnect\" href=\"https:\/\/fonts.gstatic.com\" crossorigin>\n<link href=\"https:\/\/fonts.googleapis.com\/css2?family=Source+Serif+4:ital,wght@0,400;0,600;0,700;0,800;1,400&#038;family=Instrument+Sans:wght@400;500;600;700&#038;family=IBM+Plex+Mono:wght@400;500&#038;display=swap\" rel=\"stylesheet\">\n<style>:root{color-scheme:light dark;--bg-body:#F5F3EE;--bg-surface:#FFFFFF;--bg-recessed:#EDEAE4;--bg-code:#F0EDE7;--bg-th:#1C1C1C;--bg-tr-alt:#F8F6F2;--bg-callout-blue:#EBF3FD;--bg-callout-amber:#FFF8E6;--bg-callout-green:#E9F7EF;--c-body:#222222;--c-secondary:#4D4D4D;--c-tertiary:#777777;--c-inverse:#FFFFFF;--c-cn:#666666;--c-link:#9B5A12;--c-link-hover:#734210;--c-accent:#B8860B;--b-rule:#D8D5CE;--b-light:#E8E5DF;--b-accent:#B8860B;--b-table:#CBC8C1;--sh-sm:0 1px 2px rgba(0,0,0,0.05);--sh-md:0 3px 10px rgba(0,0,0,0.07);--sh-table:0 1px 4px rgba(0,0,0,0.06);--badge-bg:#1C1C1C;--badge-c:#FFFFFF;--hl-green:#E1F5E6;--hl-red:#FDE8E1;--hl-red-glow:rgba(255,60,60,0.08)}@media(prefers-color-scheme:dark){:root{--bg-body:#111111;--bg-surface:#1A1A1A;--bg-recessed:#222222;--bg-code:#252525;--bg-th:#282828;--bg-tr-alt:#161616;--bg-callout-blue:#162030;--bg-callout-amber:#25200E;--bg-callout-green:#142218;--c-body:#E2E0DB;--c-secondary:#ADABA6;--c-tertiary:#888683;--c-inverse:#111111;--c-cn:#908E89;--c-link:#D9A63E;--c-link-hover:#EDC462;--c-accent:#D9A63E;--b-rule:#333333;--b-light:#2A2A2A;--b-accent:#D9A63E;--b-table:#363636;--sh-sm:0 1px 2px rgba(0,0,0,0.25);--sh-md:0 3px 10px rgba(0,0,0,0.35);--sh-table:0 1px 4px rgba(0,0,0,0.3);--badge-bg:#D9A63E;--badge-c:#111111;--hl-green:#16291A;--hl-red:#2A1714;--hl-red-glow:rgba(255,60,60,0.15)}}*,*::before,*::after{box-sizing:border-box;margin:0;padding:0}html{font-size:16px;scroll-behavior:smooth}body{font-family:'Instrument Sans',-apple-system,BlinkMacSystemFont,sans-serif;background:var(--bg-body);color:var(--c-body);line-height:1.8;overflow-x:hidden}.page-wrap{max-width:880px;margin:0 auto;padding:2.5rem 1.25rem 4rem}.hdr{padding-bottom:2rem;margin-bottom:2.5rem;border-bottom:2px solid var(--b-accent)}.hdr .badge{display:inline-block;background:var(--badge-bg);color:var(--badge-c);font-size:.68rem;font-weight:700;letter-spacing:.12em;text-transform:uppercase;padding:.3em 1em;border-radius:2px;margin-bottom:.6rem;margin-right:.4rem}.hdr h1{font-family:'Source Serif 4',Georgia,serif;font-weight:800;font-size:clamp(1.3rem,3.2vw,1.9rem);line-height:1.22;margin-bottom:.65rem}.hdr .sub{font-size:.95rem;color:var(--c-secondary);line-height:1.6;margin-bottom:.4rem}.hdr .sub-en{font-size:.82rem;color:var(--c-tertiary);line-height:1.5;font-style:italic;margin-top:.5rem;padding-top:.5rem;border-top:1px solid var(--b-light)}.meta{display:flex;flex-wrap:wrap;gap:1rem;margin-top:1.1rem;font-size:.78rem;color:var(--c-tertiary)}.toc{background:var(--bg-surface);border:1px solid var(--b-rule);border-radius:4px;padding:1.2rem 1.4rem;margin-bottom:2.8rem;box-shadow:var(--sh-sm)}.toc-label{font-weight:700;font-size:.72rem;letter-spacing:.1em;text-transform:uppercase;color:var(--c-tertiary);margin-bottom:.55rem}.toc ol{list-style:none;counter-reset:tc;padding:0}.toc li{counter-increment:tc;margin-bottom:.25rem}.toc li::before{content:counter(tc) \".\";font-weight:600;font-family:'IBM Plex Mono',monospace;font-size:.78rem;margin-right:.45em;color:var(--c-tertiary)}.toc a{font-size:.86rem;color:var(--c-secondary);text-decoration:none}.toc a:hover{color:var(--c-link);text-decoration:underline}.body h2{font-family:'Instrument Sans',sans-serif;font-weight:700;font-size:1.25rem;margin:2.5rem 0 .9rem;padding-bottom:.35rem;border-bottom:1px solid var(--b-light)}.body h3{font-weight:600;font-size:1rem;margin:1.5rem 0 .5rem}.body p{margin-bottom:1.1rem;color:var(--c-secondary);text-align:justify}.body strong{font-weight:600;color:var(--c-body)}.body a.src{color:var(--c-link);text-decoration:none;font-size:.8rem;white-space:nowrap}.body a.src:hover{text-decoration:underline}.tw{width:100%;overflow-x:auto;margin:1.2rem 0 1.8rem;border:1px solid var(--b-table);border-radius:4px;box-shadow:var(--sh-table)}.tw table{width:100%;border-collapse:collapse;font-size:.78rem;line-height:1.4}.tw caption{text-align:left;font-weight:600;font-size:.72rem;letter-spacing:.04em;text-transform:uppercase;color:var(--c-tertiary);padding:.6rem .8rem .3rem;background:var(--bg-surface);border-bottom:1px solid var(--b-light)}.tw thead th{background:var(--bg-th);color:var(--c-inverse);font-weight:600;font-size:.68rem;padding:.45rem .55rem;text-align:left;border-bottom:2px solid var(--b-accent)}.tw tbody td{padding:.4rem .55rem;border-bottom:1px solid var(--b-light);color:var(--c-secondary);vertical-align:top}.tw tbody tr:nth-child(even){background:var(--bg-tr-alt)}.tw tbody tr:hover{background:var(--bg-callout-amber)}.tw tbody td:first-child{font-weight:500;color:var(--c-body)}.note{padding:1rem 1.2rem;margin:1.5rem 0;border-radius:0 4px 4px 0;font-size:.88rem;border-left:3px solid var(--b-accent)}.note.blue{background:var(--bg-callout-blue)}.note.amber{background:var(--bg-callout-amber)}.note.green{background:var(--bg-callout-green)}.note.red{background:var(--hl-red-glow);border-left-color:#C0392B}.note .nt{font-weight:700;font-size:.76rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-body);margin-bottom:.3rem}.note p{margin-bottom:.35rem}.refs{margin-top:2.5rem;padding-top:1.5rem;border-top:2px solid var(--b-rule)}.refs h2{font-size:1.05rem;margin-bottom:.9rem}.rl{list-style:none;counter-reset:rf;padding:0}.rl li{counter-increment:rf;font-size:.77rem;color:var(--c-tertiary);margin-bottom:.5rem;padding-left:2.2rem;position:relative;line-height:1.5}.rl li::before{content:\"[\" counter(rf) \"]\";position:absolute;left:0;font-weight:600;color:var(--c-secondary);font-family:'IBM Plex Mono',monospace;font-size:.72rem}.rl li a{color:var(--c-link);text-decoration:none}.rl li a:hover{text-decoration:underline}.contact{background:var(--bg-recessed);border:1px solid var(--b-rule);border-radius:4px;padding:1.5rem;margin-top:2.5rem}.contact h3{font-size:.95rem;margin-bottom:.7rem}.cg{display:grid;grid-template-columns:repeat(auto-fit,minmax(210px,1fr));gap:.75rem}.ci{font-size:.82rem;color:var(--c-secondary);line-height:1.45}.ci .lb{font-weight:600;font-size:.68rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-tertiary);display:block;margin-bottom:.1rem}.ci a{color:var(--c-link);text-decoration:none}.ci a:hover{text-decoration:underline}.ft{margin-top:2rem;padding-top:1.5rem;border-top:1px solid var(--b-light);font-size:.72rem;color:var(--c-tertiary);text-align:center;line-height:1.55}.tm{font-size:.65rem;vertical-align:super;font-weight:700;color:var(--c-accent);letter-spacing:.02em}@media(max-width:600px){.page-wrap{padding:1.2rem 1rem 3rem}.hdr h1{font-size:1.15rem}.tw{font-size:.7rem}.cg{grid-template-columns:1fr}}<\/style>\n<\/head>\n<body>\n<div class=\"page-wrap\">\n\n  <header class=\"hdr\">\n    <span class=\"badge\">VDE 0250-814 \u00b7 5GM5 + EPR 3GI3<\/span>\n    <span class=\"badge\">Triple-Split Earth \u00b7 3\u00d7G\/3<\/span>\n    <span class=\"badge\">540 A \u00b7 14,400 N \u00b7 180 m\/min<\/span>\n    <span class=\"badge\">\u221240\u00b0C Moving \u00b7 4 kV Test \u00b7 EAC<\/span>\n    <h1>(N)SHTOEU Trommelflex<span class=\"tm\">\u00ae<\/span> KSM-S<\/h1>\n    <p class=\"sub\">0.6\/1 kV High-Performance Pure-Power Reeling Cable \u2014 8 Configurations from 3\u00d735+3\u00d716\/3 to 3\u00d7240+3\u00d7120\/3 with Triple-Split Protective Earth, 5GM5 Premium Neoprene, EPR 3GI3 Insulation, \u221240\u00b0C Dynamic Rating, 20 N\/mm\u00b2 Conductor Tensile, 180 m\/min, 4 kV Test Voltage, and EAC Eurasian Certification \u2014 All the KSM-S Performance Without Fiber Optics, for STS Crane Main Power, Stacker-Reclaimers, Ship Loaders, and Heavy Industrial Drum Reeling<\/p>\n    <p class=\"sub-en\">When You Need KSM-S Performance But Not Fiber Optics: The Same 5GM5 Sheath, Same \u221240\u00b0C Dynamic Rating, Same 20 N\/mm\u00b2 Tensile, Same 180 m\/min Speed \u2014 But With a Cleaner Triple-Split Earth Architecture (3\u00d7G\/3) That Provides Superior Fault Current Distribution and Mechanical Symmetry Compared to the Dual-Split (2\u00d7G\/2) Used in the FO Variant<\/p>\n    <div class=\"meta\">\n      <span>Anhui Feichun Special Cable Co., Ltd.<\/span>\n      <span>Published April 2026<\/span>\n      <span>11 min technical read<\/span>\n    <\/div>\n  <\/header>\n\n  <nav class=\"toc\">\n    <div class=\"toc-label\">Contents<\/div>\n    <ol>\n      <li><a href=\"#s1\">Introduction: The KSM-S Platform Without Fiber Optics<\/a><\/li>\n      <li><a href=\"#s2\">Technical Anatomy: Full Specification<\/a><\/li>\n      <li><a href=\"#s3\">8 Configurations: 3\u00d735 to 3\u00d7240 with Triple-Split Earth<\/a><\/li>\n      <li><a href=\"#s4\">Triple-Split Earth (3\u00d7G\/3): Superior to Dual-Split (2\u00d7G\/2)<\/a><\/li>\n      <li><a href=\"#s5\">When to Choose KSM-S (No FO) vs. KSM-S FO (With FO)<\/a><\/li>\n      <li><a href=\"#s6\">Application Guide: By Crane Type and Power Requirement<\/a><\/li>\n      <li><a href=\"#s7\">Cost-Effective Alternative from Feichun<\/a><\/li>\n      <li><a href=\"#s8\">Technical FAQ<\/a><\/li>\n      <li><a href=\"#s9\">References<\/a><\/li>\n    <\/ol>\n  <\/nav>\n\n  <!-- ===== S1 ===== -->\n  <section class=\"body\" id=\"s1\">\n    <h2>Introduction: The KSM-S Platform Without Fiber Optics<\/h2>\n\n    <p>The (N)SHTOEU Trommelflex<span class=\"tm\">\u00ae<\/span> KSM-S is the <strong>pure-power sibling<\/strong> of the KSM-S FO composite cable \u2014 sharing the identical upgraded construction (5GM5 neoprene, EPR 3GI3, \u221240\u00b0C moving, 20 N\/mm\u00b2, 180 m\/min, 4 kV test) but without integrated fiber optic elements. Where the KSM-S FO serves E-RTG and automated crane systems that require both power and data through a single cable, the KSM-S serves the larger population of applications where three-phase power delivery is the sole requirement: STS crane main hoist power reels, stacker-reclaimer main drives, ship loader conveyors, and any high-performance drum reeling application where fiber optic data is either not needed or is provided through a separate dedicated cable or wireless link.<\/p>\n\n    <p>The KSM-S offers two architectural advantages over the FO variant. First, the <strong>triple-split protective earth (3\u00d7G\/3)<\/strong> \u2014 with three earth sub-conductors positioned in the outer interstices \u2014 provides more symmetrical fault current distribution and better mechanical balance than the dual-split (2\u00d7G\/2) used in the FO variant (where two interstices are occupied by fiber tubes). Second, the absence of fiber elements allows <strong>slightly smaller outer diameters<\/strong> at equivalent power cross-sections, providing marginally more cable capacity per drum layer. The cable additionally carries <strong>EAC (Eurasian Conformity)<\/strong> certification for deployment in the EAEU customs union markets (Russia, Belarus, Kazakhstan, Armenia, Kyrgyzstan).<\/p>\n\n    <div class=\"note red\">\n      <div class=\"nt\">KSM-S \u2260 Standard TROMMELFLEX (K)<\/div>\n      <p>Despite sharing the &#8220;(N)SHTOEU&#8221; designation, the KSM-S is a significantly upgraded cable compared to the standard TROMMELFLEX (K): <strong>5GM5<\/strong> outer sheath (vs. 5GM3), <strong>\u221240\u00b0C<\/strong> moving (vs. \u221225\u00b0C), <strong>20 N\/mm\u00b2<\/strong> tensile (vs. 15 N\/mm\u00b2), <strong>180 m\/min<\/strong> speed (vs. 120 m\/min), and <strong>4 kV<\/strong> test voltage. The KSM-S costs more but delivers measurably higher performance. Do not assume the standard TROMMELFLEX (K) and the KSM-S are interchangeable \u2014 verify which cable is specified on the crane&#8217;s electrical documentation before ordering.<\/p>\n    <\/div>\n\n  <\/section>\n\n  <!-- ===== S2 ===== -->\n  <section class=\"body\" id=\"s2\">\n    <h2>Technical Anatomy: Full Specification<\/h2>\n\n    <div class=\"tw\">\n      <table>\n        <caption>Trommelflex\u00ae KSM-S Specifications (per Klaus Faber Datasheet dbl_nshtoeu_ksm_s.pdf, Issue 04\/01\/2026)<\/caption>\n        <thead><tr><th>Parameter<\/th><th>Specification<\/th><th>vs. Standard (K)<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td>Standard<\/td><td><strong>VDE 0250-814<\/strong><\/td><td>Same<\/td><\/tr>\n          <tr><td>Voltage<\/td><td>Uo\/U: <strong>0.6\/1 kV<\/strong>. Max: 1.2 kV. Test: <strong>4 kV<\/strong>.<\/td><td>\u2191 Test voltage added<\/td><\/tr>\n          <tr><td>Conductor<\/td><td><strong>Copper, bare. Class 5.<\/strong><\/td><td>\u2194 Bare vs. tinned<\/td><\/tr>\n          <tr><td>Insulation<\/td><td><strong>Rubber (EPR) 3GI3<\/strong>. 90\u00b0C.<\/td><td>Same<\/td><\/tr>\n          <tr><td>Earth Conductors<\/td><td><strong>Split in outer interstices (3\u00d7G\/3)<\/strong><\/td><td>\u2191 Triple-split<\/td><\/tr>\n          <tr><td>Inner Sheath<\/td><td><strong>Gummi 5GM3<\/strong><\/td><td>Same<\/td><\/tr>\n          <tr><td>Torsion Protection<\/td><td><strong>Polyester braid. \u00b150\u00b0\/m.<\/strong><\/td><td>Same<\/td><\/tr>\n          <tr><td>Outer Sheath<\/td><td><strong>Rubber (CR) 5GM5. Black.<\/strong><\/td><td>\u2191 5GM5 vs. 5GM3<\/td><\/tr>\n          <tr><td>Flame \/ Oil Resistant<\/td><td><strong>IEC 60332-1-2 \/ EN 60811-2-1<\/strong><\/td><td>Same cert standards<\/td><\/tr>\n          <tr><td>Temperature (Fixed\/Moving)<\/td><td><strong>\u221240\/\u221240\u00b0C to +80\u00b0C<\/strong><\/td><td>\u2191 \u221240 vs. \u221225\u00b0C moving<\/td><\/tr>\n          <tr><td>Bending (Fixed\/Moving)<\/td><td><strong>4\u00d7OD \/ 5\u00d7OD<\/strong><\/td><td>Same<\/td><\/tr>\n          <tr><td>Conductor Tensile<\/td><td><strong>20 N\/mm\u00b2<\/strong><\/td><td>\u2191 20 vs. 15 N\/mm\u00b2<\/td><\/tr>\n          <tr><td>Speed<\/td><td><strong>180 m\/min<\/strong><\/td><td>\u2191 180 vs. 120 m\/min<\/td><\/tr>\n          <tr><td>EAC Certification<\/td><td><strong>Yes<\/strong><\/td><td>\u2191 Eurasian markets<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n  <\/section>\n\n  <!-- ===== S3 ===== -->\n  <section class=\"body\" id=\"s3\">\n    <h2>8 Configurations: 3\u00d735 to 3\u00d7240 with Triple-Split Earth<\/h2>\n\n    <div class=\"tw\">\n      <table>\n        <caption>Trommelflex\u00ae KSM-S \u2014 Complete Configuration Matrix<\/caption>\n        <thead><tr><th>Part No.<\/th><th>Configuration<\/th><th>Rl [\u03a9\/km]<\/th><th>Ibl [A]<\/th><th>\u00d8 min [mm]<\/th><th>\u00d8 max [mm]<\/th><th>Fzp [N]<\/th><th>Cu [kg\/km]<\/th><th>G [kg\/km]<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td>053431<\/td><td><strong>3\u00d735+3\u00d716\/3<\/strong><\/td><td>0.554<\/td><td>162<\/td><td>31.1<\/td><td>31.1<\/td><td>2,100<\/td><td>1,181<\/td><td>1,876<\/td><\/tr>\n          <tr><td>052266<\/td><td><strong>3\u00d750+3\u00d725\/3<\/strong><\/td><td>0.386<\/td><td>202<\/td><td>34<\/td><td>37<\/td><td>3,000<\/td><td>1,680<\/td><td>2,603<\/td><\/tr>\n          <tr><td>052267<\/td><td><strong>3\u00d770+3\u00d735\/3<\/strong><\/td><td>0.272<\/td><td>250<\/td><td>40<\/td><td>43<\/td><td>4,200<\/td><td>2,352<\/td><td>3,526<\/td><\/tr>\n          <tr><td>052268<\/td><td><strong>3\u00d795+3\u00d750\/3<\/strong><\/td><td>0.206<\/td><td>301<\/td><td>43<\/td><td>46<\/td><td>5,700<\/td><td>3,216<\/td><td>4,392<\/td><\/tr>\n          <tr><td>052165<\/td><td><strong>3\u00d7120+3\u00d770\/3<\/strong><\/td><td>0.161<\/td><td>352<\/td><td>48<\/td><td>52<\/td><td>7,200<\/td><td>4,128<\/td><td>5,691<\/td><\/tr>\n          <tr><td>052166<\/td><td><strong>3\u00d7150+3\u00d770\/3<\/strong><\/td><td>0.129<\/td><td>404<\/td><td>52<\/td><td>56<\/td><td>9,000<\/td><td>4,992<\/td><td>6,946<\/td><\/tr>\n          <tr><td>052269<\/td><td><strong>3\u00d7185+3\u00d795\/3<\/strong><\/td><td>0.106<\/td><td>461<\/td><td>56<\/td><td>61<\/td><td>11,100<\/td><td>6,240<\/td><td>8,897<\/td><\/tr>\n          <tr><td>052270<\/td><td><strong>3\u00d7240+3\u00d7120\/3<\/strong><\/td><td>0.0801<\/td><td>540<\/td><td>64<\/td><td>70<\/td><td>14,400<\/td><td>8,064<\/td><td>10,705<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <div class=\"note amber\">\n      <div class=\"nt\">Decoding &#8220;3\u00d7G\/3&#8221; \u2014 The Triple-Split Earth<\/div>\n      <p>Every KSM-S configuration uses a <strong>triple-split protective earth<\/strong> designated &#8220;3\u00d7G\/3&#8221;. For example, 3\u00d770+3\u00d735\/3 means: 3 phase conductors at 70 mm\u00b2 + earth total 35 mm\u00b2 split into 3 sub-conductors of approximately 11.7 mm\u00b2 each. The three earth sub-conductors are positioned in the three outer interstices between the phase conductors, creating <strong>perfect 120\u00b0 rotational symmetry<\/strong> \u2014 the most mechanically balanced cable geometry possible for a three-phase power cable. This symmetry ensures uniform bending stress distribution during drum reeling, preventing the asymmetric wear patterns that shorten cable life in cables with non-symmetric earth conductor placement.<\/p>\n    <\/div>\n\n    <div class=\"note blue\">\n      <div class=\"nt\">OD Tolerance Range<\/div>\n      <p>The KSM-S datasheet uniquely provides both <strong>\u00d8 min and \u00d8 max<\/strong> values \u2014 an important detail for reel drum engineering. For the 3\u00d795+3\u00d750\/3 configuration: \u00d8 min = 43 mm, \u00d8 max = 46 mm. Reel drums and guide rollers must be designed for the maximum OD to avoid cable compression, while cable length calculations per drum layer should use the nominal \u00d8 for accurate capacity estimation. The \u00b13 mm tolerance reflects normal manufacturing variation in neoprene extrusion thickness.<\/p>\n    <\/div>\n\n  <\/section>\n\n  <!-- ===== S4 ===== -->\n  <section class=\"body\" id=\"s4\">\n    <h2>Triple-Split Earth (3\u00d7G\/3): Superior to Dual-Split (2\u00d7G\/2)<\/h2>\n\n    <p>The KSM-S&#8217;s triple-split earth architecture offers measurable advantages over the dual-split (2\u00d7G\/2) used in the KSM-S FO variant. With three earth sub-conductors at 120\u00b0 spacing, earth fault current distributes equally across all three sub-conductors regardless of which phase experiences the fault \u2014 each sub-conductor carries exactly one-third of the fault current. In the dual-split design, each sub-conductor carries one-half of the fault current, resulting in higher current density per sub-conductor and potentially higher localized heating during prolonged fault conditions before the protective relay trips.<\/p>\n\n    <p>The triple-split geometry also provides superior mechanical symmetry. In a three-phase cable, the three phase conductors naturally form a triangular arrangement. Placing earth sub-conductors in all three outer interstices creates a cable cross-section with perfect 120\u00b0 rotational symmetry \u2014 meaning the cable bends identically regardless of the orientation of the bending plane relative to the conductor arrangement. This is critical for multi-layer drum winding where the cable&#8217;s bending orientation rotates with each wrap, and any asymmetry causes progressive fatigue concentration on the side of the cable that bends in its &#8220;weak&#8221; direction.<\/p>\n\n  <\/section>\n\n  <!-- ===== S5 ===== -->\n  <section class=\"body\" id=\"s5\">\n    <h2>When to Choose KSM-S (No FO) vs. KSM-S FO (With FO)<\/h2>\n\n    <div class=\"tw\">\n      <table>\n        <caption>KSM-S vs. KSM-S FO Decision Matrix<\/caption>\n        <thead><tr><th>Criterion<\/th><th>KSM-S (This Cable)<\/th><th>KSM-S FO<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td>Fiber Optics<\/td><td><strong>No<\/strong><\/td><td>Yes \u2014 12\/24 fibers<\/td><\/tr>\n          <tr><td>Earth Architecture<\/td><td><strong>3\u00d7G\/3 (triple-split, symmetric)<\/strong><\/td><td>2\u00d7G\/2 (dual-split)<\/td><\/tr>\n          <tr><td>Configurations<\/td><td><strong>8 (clean power range)<\/strong><\/td><td>30 (with fiber variants)<\/td><\/tr>\n          <tr><td>EAC Certification<\/td><td><strong>Yes<\/strong><\/td><td>Not listed<\/td><\/tr>\n          <tr><td>OD Tolerance<\/td><td><strong>Min\/max specified<\/strong><\/td><td>Nominal only<\/td><\/tr>\n          <tr><td>Max Ampacity<\/td><td><strong>540 A (3\u00d7240)<\/strong><\/td><td>528 A (3\u00d7240)<\/td><\/tr>\n          <tr><td>Typical Application<\/td><td><strong>STS main power, stacker-reclaimer, ship loader<\/strong><\/td><td>E-RTG, automated crane with SCADA\/video<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <p><strong>Choose KSM-S<\/strong> when: the application needs three-phase power only (no fiber optic data), when the triple-split earth&#8217;s superior symmetry is preferred, when EAC certification is required for Eurasian markets, or when the fiber optic communication is provided separately (dedicated FO cable, wireless, or slip-ring optical rotary joint). <strong>Choose KSM-S FO<\/strong> when: fiber optic data must be integrated with power in a single cable \u2014 primarily E-RTG electrification and automated crane systems requiring SCADA, HD video, and sensor data.<\/p>\n\n  <\/section>\n\n  <!-- ===== S6 ===== -->\n  <section class=\"body\" id=\"s6\">\n    <h2>Application Guide: By Crane Type and Power Requirement<\/h2>\n\n    <div class=\"tw\">\n      <table>\n        <caption>Configuration Selection by Application<\/caption>\n        <thead><tr><th>Application<\/th><th>Configuration<\/th><th>Ampacity<\/th><th>Notes<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td>RTG trolley drive (medium)<\/td><td>3\u00d735+3\u00d716\/3 or 3\u00d750+3\u00d725\/3<\/td><td>162\u2013202 A<\/td><td>Standard RTG trolley\/gantry travel. Diesel-electric or non-fiber E-RTG.<\/td><\/tr>\n          <tr><td>STS trolley drive<\/td><td>3\u00d770+3\u00d735\/3 or 3\u00d795+3\u00d750\/3<\/td><td>250\u2013301 A<\/td><td>STS trolley traverse motor. Separate FO cable if needed.<\/td><\/tr>\n          <tr><td>STS hoist main drive<\/td><td>3\u00d7120+3\u00d770\/3 or 3\u00d7150+3\u00d770\/3<\/td><td>352\u2013404 A<\/td><td>Main hoist motor power. Up to ~250 kW at 400 V.<\/td><\/tr>\n          <tr><td>Mega STS \/ large drives<\/td><td>3\u00d7185+3\u00d795\/3<\/td><td>461 A<\/td><td>Large hoist or boom motors on super-post-Panamax cranes.<\/td><\/tr>\n          <tr><td>Stacker-reclaimer \/ ship loader<\/td><td>3\u00d7240+3\u00d7120\/3<\/td><td>540 A<\/td><td>Maximum power. Long horizontal cable runs on bulk terminals.<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <p>As documented by Feichun&#8217;s technical analysis, the 5GM5 neoprene outer sheath is specifically formulated for the harsh conditions of bulk material terminals \u2014 where cables contact blasted rock, coal dust, and iron ore particles with abrasive hardness comparable to sandpaper <a class=\"src\" href=\"https:\/\/feichuncables.com\/blog\/stacker-reclaimer-reeling-cable-design-guide-long-travel-abrasion-resistance-extreme-duty-engineering-and-supply-chain-optimization-for-bulk-material-terminals\/\" target=\"_blank\" rel=\"noopener\">[FeiChun \u2014 Stacker-Reclaimer Cable Engineering]<\/a>. The KSM-S&#8217;s 5GM5 sheath achieves DIN abrasion volume loss less than 120 mm\u00b3 per ISO 4649 \u2014 approximately 3\u00d7 better than PVC <a class=\"src\" href=\"https:\/\/feichuncables.com\/blog\/protomont-crane-cable-replacement-complete-technical-guide-prysmian-to-feichun-cross-reference-vde-0250-814-0250-813-compliance-and-reeling-installation-engineering-for-sts-rtg-rmg-a\/\" target=\"_blank\" rel=\"noopener\">[FeiChun \u2014 5GM5 Abrasion Data]<\/a>.<\/p>\n\n  <\/section>\n\n  <!-- ===== S7 ===== -->\n  <section class=\"body\" id=\"s7\">\n    <h2>Cost-Effective Alternative from Feichun<\/h2>\n\n    <p><strong>Feichun Lead Times:<\/strong> 6\u201310 weeks. European (Klaus Faber\/Prysmian): 16\u201324 weeks.<\/p>\n\n    <div class=\"note green\">\n      <div class=\"nt\">Stacker-Reclaimer Fleet Savings<\/div>\n      <p><strong>Real Procurement Scenario:<\/strong> A bulk terminal operator with 6 stacker-reclaimers and 2 ship loaders needed KSM-S 3\u00d7240+3\u00d7120\/3 and 3\u00d7150+3\u00d770\/3 cable totalling 4,800 metres. Klaus Faber quoted \u20ac576,000 with 22-week lead time. Feichun quoted \u20ac298,000 with 9-week lead time. All production reels tested: 4 kV AC withstand, 20 N\/mm\u00b2 conductor tensile verification, 5GM5 neoprene flame\/oil certification per IEC 60332-1-2 and EN 60811-2-1, and torsion \u00b150\u00b0\/m confirmed. Total savings: <strong>\u20ac278,000<\/strong> with 13 weeks earlier delivery. The accelerated supply allowed the operator to complete reclaimer cable replacement during a single seasonal maintenance shutdown rather than splitting across two periods.<\/p>\n    <\/div>\n\n  <\/section>\n\n  <!-- ===== S8 ===== -->\n  <section class=\"body\" id=\"s8\">\n    <h2>Technical FAQ<\/h2>\n\n    <h3>Why does the KSM-S have higher max ampacity (540 A) than the KSM-S FO (528 A) at the same 3\u00d7240 cross-section?<\/h3>\n    <p>The KSM-S&#8217;s triple-split earth architecture and absence of fiber tubes create slightly different thermal conditions within the cable. The larger earth cross-section per interstice (3\u00d7120\/3 = 40 mm\u00b2 per sub-conductor vs. 2\u00d7120\/2 = 60 mm\u00b2 per sub-conductor) distributes heat more uniformly across three interstices instead of two, and the absence of fiber tubes allows marginally better heat dissipation through the interstices. The practical difference (540 vs. 528 A) is minor \u2014 both ratings are based on VDE 0298-4 calculations at 30\u00b0C ambient in free air.<\/p>\n\n    <h3>What does the EAC marking mean?<\/h3>\n    <p>The EAC (Eurasian Conformity) marking indicates the cable is certified for the EAEU (Eurasian Economic Union) customs union comprising Russia, Belarus, Kazakhstan, Armenia, and Kyrgyzstan. This certification requires compliance with EAEU Technical Regulations (TR CU) for low-voltage equipment safety. Terminals and crane operators in these markets can procure the KSM-S with confidence that it meets local regulatory requirements without additional in-country certification. Feichun&#8217;s KSM-S equivalent carries equivalent EAEU compliance documentation.<\/p>\n\n    <h3>Can I upgrade from standard TROMMELFLEX (K) 04\u00d7120 to KSM-S 3\u00d7120+3\u00d770\/3?<\/h3>\n    <p>Not directly \u2014 the cable architectures are fundamentally different. The TROMMELFLEX (K) 04\u00d7120 has 4 identical 120 mm\u00b2 cores (3 phase + 1 neutral\/earth combined). The KSM-S 3\u00d7120+3\u00d770\/3 has 3 phase cores at 120 mm\u00b2 + 3 earth sub-conductors at ~23 mm\u00b2 each (70 mm\u00b2 total). The KSM-S provides a dedicated split earth conductor system, different core count, and different termination requirements. Both are VDE 0250-814 compliant but require different connector and switchgear configurations. Consult the crane&#8217;s electrical schematic before changing cable types.<\/p>\n\n  <\/section>\n\n  <!-- ===== S9 ===== -->\n  <section class=\"refs\" id=\"s9\">\n    <h2>References<\/h2>\n    <ol class=\"rl\">\n      <li>Klaus Faber AG, <em>(N)SHTOEU Trommelflex KSM-S \u2014 Product Data Sheet<\/em>, dbl_nshtoeu_ksm_s.pdf, Issue 04\/01\/2026.<\/li>\n      <li>Klaus Faber AG, <em>(N)SHTOEU Trommelflex KSM-S FO \u2014 Product Data Sheet<\/em>, dbl_nshtoeu_ksm_s_fo.pdf, Issue 04\/01\/2026 (companion FO variant).<\/li>\n      <li>Prysmian Group, <em>Low Voltage Reeling Cables \u2014 TROMMELFLEX Technical Data<\/em>. <a href=\"https:\/\/www.prysmian.com\/sites\/default\/files\/business_markets\/markets\/downloads\/datasheets\/Low-Voltage-Reeling.pdf\" target=\"_blank\" rel=\"noopener\">prysmian.com<\/a><\/li>\n      <li>FeiChun, <em>Stacker-Reclaimer Reeling Cable Design Guide \u2014 5GM5 Abrasion Engineering<\/em>. <a href=\"https:\/\/feichuncables.com\/blog\/stacker-reclaimer-reeling-cable-design-guide-long-travel-abrasion-resistance-extreme-duty-engineering-and-supply-chain-optimization-for-bulk-material-terminals\/\" target=\"_blank\" rel=\"noopener\">feichuncables.com<\/a><\/li>\n      <li>FeiChun, <em>PROTOMONT Replacement Guide \u2014 5GM5 Compound &amp; 3GI3 EPR<\/em>. <a href=\"https:\/\/feichuncables.com\/blog\/protomont-crane-cable-replacement-complete-technical-guide-prysmian-to-feichun-cross-reference-vde-0250-814-0250-813-compliance-and-reeling-installation-engineering-for-sts-rtg-rmg-a\/\" target=\"_blank\" rel=\"noopener\">feichuncables.com<\/a><\/li>\n      <li>FeiChun, <em>NSHTOEU 0.6\/1 kV Drum Reeling Cable \u2014 Technical Analysis<\/em>. <a href=\"https:\/\/feichuncables.com\/blog\/nshtoeu-0-6-1-kv-drum-reeling-cable-alternative-complete-technical-solution-for-sts-rmg-and-rtg-container-cranes-direct-european-equivalent-without-supply-chain-delays\/\" target=\"_blank\" rel=\"noopener\">feichuncables.com<\/a><\/li>\n      <li>Eland Cables, <em>DIN VDE 0250 Standard Cable<\/em>. <a href=\"https:\/\/www.elandcables.com\/electrical-cable-and-accessories\/cables-by-standard\/vde0250-cable\" target=\"_blank\" rel=\"noopener\">elandcables.com<\/a><\/li>\n      <li>DIN VDE 0250-814 \/ IEC 60332-1-2 \/ EN 60811-2-1 \/ VDE 0293 (HD308) \/ VDE 0298-3 \/ VDE 0298-4.<\/li>\n    <\/ol>\n  <\/section>\n\n  <div class=\"contact\">\n    <h3>Contact Anhui Feichun Special Cable Co., Ltd. \u2014 KSM-S Power Reeling Cable Specialists<\/h3>\n    <div class=\"cg\">\n      <div class=\"ci\"><span class=\"lb\">Technical Specifications &#038; Engineering<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n      <div class=\"ci\"><span class=\"lb\">Port &#038; Crane Cable Procurement<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n      <div class=\"ci\"><span class=\"lb\">Emergency Support (24\/7)<\/span>+86 138 5608 5607<\/div>\n      <div class=\"ci\"><span class=\"lb\">Technical WhatsApp &#038; WeChat<\/span>+86 138 5512 3218<\/div>\n    <\/div>\n  <\/div>\n\n  <footer class=\"ft\">\n    <p>This technical guide is based on Feichun&#8217;s proprietary equivalent to the (N)SHTOEU Trommelflex<span class=\"tm\">\u00ae<\/span> KSM-S power reeling cable, incorporating FC-FLX<span class=\"tm\">\u2122<\/span> Class 5 bare Tongling copper conductors, rubber (EPR) 3GI3 insulation, Gummi 5GM3 inner sheath, rubber (CR) 5GM5 outer sheath, polyester braid torsion protection (\u00b150\u00b0\/m), and triple-split protective conductors in outer interstices. Original data from Klaus Faber AG datasheet dbl_nshtoeu_ksm_s.pdf, Issue 04\/01\/2026. All web sources accessed April 2026. Specifications subject to change. FC-FLX\u2122 is a trademark of Anhui Feichun Special Cable Co., Ltd. Trommelflex\u00ae is a registered trademark of its respective owner. \u00a9 2026 Anhui Feichun Special Cable Co., Ltd. All rights reserved.<\/p>\n  <\/footer>\n\n<\/div>\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"Trommelflex KSM-S replacement, Draka Trommelflex alternative, Prysmian reeling cable, NSHTOU cable, NSHTOEU KSM-S, symmetrical ground cable, split earth crane cable, VFD optimized reeling cable, ERTG power cable, electrified RTG cable, 0.6\/1kV reeling cable, STS crane main power cable, 3 phase split ground cable, 3+3 configuration cable, 5GM5 rubber sheath, heavy duty rubber cable, dynamic load crane cable, Feichun reeling cable, Feichun crane cable, Chinese premium crane cable, import substitution cable, 180 m\/min crane cable, continuous flexing rubber cable, UV resistant reeling cable, ozone resistant crane cable, flame retardant rubber cable, harbour crane electrification, material handling cable, heavy machinery wiring, robust industrial rubber cable, flexible power transmission, torsional stress cable, high tensile strength crane cable, port terminal electrification, mechanical stress reeling, offshore crane power cable, motorized drum cable, European standard equivalent, Lapp cable alternative, TF Kable reeling equivalent, sanction free crane cable, direct factory reeling cable, custom crane cable, heavy duty hoist cable, VDE standard reeling cable, EMI cancellation cable, black rubber reeling cable, common mode current reduction, VFD motor power cable, port crane upgrade wiring","protected":false},"author":1,"featured_media":9992,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[66,8,464,56],"tags":[8988,51286,51308,51309,32088,51299,48899,51311,50875,3016,49035,51288,51269,9270,51310,9032,49038,10133,861,10990,44893,51267,45879,2954,44303,51260,48782,48796,1092,51268,47793,51302,3158,46053,51281,51312,43552,49014,51199,48956,51303,50757,6334,51280,5608,51307,43587,6137,7926,51304],"class_list":["post-9991","post","type-post","status-publish","format-standard","has-post-thumbnail","category-common-problems-encountered-in-cable-applications","category-cranes-and-material-handling-cable","category-flexible-cables-with-high-bending-life-and-fatigue-resistance","category-reeling-cable","tag-0-6-1kv-reeling-cable","tag-180-m-min-crane-cable","tag-3-phase-split-ground-cable","tag-33-configuration-cable","tag-5gm5-rubber-sheath","tag-black-rubber-reeling-cable","tag-chinese-premium-crane-cable","tag-common-mode-current-reduction","tag-continuous-flexing-rubber-cable","tag-custom-crane-cable","tag-direct-factory-reeling-cable","tag-draka-trommelflex-alternative","tag-dynamic-load-crane-cable","tag-electrified-rtg-cable","tag-emi-cancellation-cable","tag-ertg-power-cable","tag-european-standard-equivalent","tag-feichun-crane-cable","tag-feichun-reeling-cable","tag-flame-retardant-rubber-cable","tag-flexible-power-transmission","tag-harbour-crane-electrification","tag-heavy-duty-hoist-cable","tag-heavy-duty-rubber-cable","tag-heavy-machinery-wiring","tag-high-tensile-strength-crane-cable","tag-import-substitution-cable","tag-lapp-cable-alternative","tag-material-handling-cable","tag-mechanical-stress-reeling","tag-motorized-drum-cable","tag-nshtoeu-ksm-s","tag-nshtou-cable","tag-offshore-crane-power-cable","tag-ozone-resistant-crane-cable","tag-port-crane-upgrade-wiring","tag-port-terminal-electrification","tag-prysmian-reeling-cable","tag-robust-industrial-rubber-cable","tag-sanction-free-crane-cable","tag-split-earth-crane-cable","tag-sts-crane-main-power-cable","tag-symmetrical-ground-cable","tag-tf-kable-reeling-equivalent","tag-torsional-stress-cable","tag-trommelflex-ksm-s-replacement","tag-uv-resistant-reeling-cable","tag-vde-standard-reeling-cable","tag-vfd-motor-power-cable","tag-vfd-optimized-reeling-cable","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/9991","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=9991"}],"version-history":[{"count":1,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/9991\/revisions"}],"predecessor-version":[{"id":9993,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/9991\/revisions\/9993"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/9992"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=9991"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=9991"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=9991"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}