{"id":8598,"date":"2026-03-06T19:58:37","date_gmt":"2026-03-06T11:58:37","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=8598"},"modified":"2026-03-06T19:58:41","modified_gmt":"2026-03-06T11:58:41","slug":"indonesian-coal-contractors-type-260-vs-type-275-critical-clarification-for-drop-in-shuttle-car-cable-equivalents","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/indonesian-coal-contractors-type-260-vs-type-275-critical-clarification-for-drop-in-shuttle-car-cable-equivalents\/","title":{"rendered":"Indonesian Coal Contractors: Type 260 vs Type 275\u2014Critical Clarification for Drop-in Shuttle Car Cable Equivalents"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Critical Engineering Clarification: Why Type 260 is NOT a Shuttle Car Cable. Deep Analysis of AS\/NZS 1802 Type 260 (Pliable Armoured Feeder) vs Type 275 (Shuttle Car Reeling). Olex Equivalent Sourcing for Indonesia Contractors (PAMA, BUMA, Thiess). Local Suppliers: Jembo Cable, Prysmian Batam, AS\/NZS-Certified Alternatives. Complete Technical Specifications and Replacement Strategy.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5173\u952e\u5de5\u7a0b\u6f84\u6e05\uff1a\u4e3a\u4ec0\u4e48Type 260\u4e0d\u662f\u7a7f\u68ad\u8f66\u7535\u7f06\u3002AS\/NZS 1802 Type 260\uff08\u67d4\u6027\u94e0\u88c5\u9988\u7535\uff09vs Type 275\uff08\u7a7f\u68ad\u8f66\u5377\u7ed5\uff09\u6df1\u5ea6\u5206\u6790\u3002\u5370\u5c3c\u627f\u5305\u5546(PAMA\u3001BUMA\u3001Thiess)\u7684Olex\u7b49\u6548\u54c1\u91c7\u8d2d\u3002\u672c\u5730\u4f9b\u5e94\u5546\uff1aJembo Cable\u3001Prysmian Batam\u3001AS\/NZS\u8ba4\u8bc1\u66ff\u4ee3\u54c1\u3002\u5b8c\u6574\u6280\u672f\u89c4\u683c\u548c\u66ff\u6362\u7b56\u7565\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"817e78\" data-has-transparency=\"false\" style=\"--dominant-color: #817e78;\" loading=\"lazy\" decoding=\"async\" width=\"1093\" height=\"600\" sizes=\"auto, (max-width: 1093px) 100vw, 1093px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-985.avif\" alt=\"\" class=\"wp-image-8599 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-985.avif 1093w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-985-300x165.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-985-768x422.avif 768w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-985-400x220.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-985-800x439.avif 800w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-985-832x457.avif 832w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n<title>Indonesian Coal Contractors: Type 260 vs Type 275 Drop-in Equivalents for Shuttle Car Cables | Feichun Cable<\/title>\n<meta name=\"description\" content=\"Critical clarification: Type 260 is NOT a shuttle car cable. Deep engineering analysis of AS\/NZS 1802 Type 260 (pliable armoured feeder) vs Type 275 (shuttle car reeling). Olex equivalent sourcing for Indonesia. Distinction between fixed semi-mobile feeders and high-frequency reeling cables. Local suppliers: Jembo, Prysmian Batam, AS\/NZS certified alternatives.\">\n<meta name=\"keywords\" content=\"Olex Type 260 equivalent, AS\/NZS 1802 Type 260, Type 260 vs Type 275, shuttle car cable Type 275, Indonesian coal mining cable, PAMA mining contractor cable, BUMA underground mining, Jembo mining cable, Prysmian Indonesia, pliable armoured cable 1.1kV, 3x35mm2 Type 260 specifications, Nexans drop-in replacement, AS\/NZS 1802 compliant cable, flexible feeder cable 1.1kV, armoured cable Indonesia, mining equipment power supply, continuous miner cable, heavy duty PCP sheath, EPR insulation mining cable, coal mine electrical standards, underground coal mine power, cable outer diameter specifications, mining cable copper weight, tensile strength mining cable, flame retardant rubber cable, AS\/NZS 3008 mining cable, mining cable current capacity, dynamic reeling vs fixed feeder, shuttle car electrical system, coal contractor equipment, underground substation cable, mining cable sourcing Southeast Asia, electrical engineering Indonesia mining, cable replacement strategy mining, Olex equivalent specifications, Kaltim Prima Coal electrical, Joy shuttle car specifications, Sandvik continuous miner power, mining infrastructure procurement, drop-in replacement compliance, cable compliance testing, high mechanical stress cable, mining cable reliability, equipment downtime prevention, coal mine safety standards, AS\/NZS 1125 compliance\">\n<meta name=\"author\" content=\"Anhui Feichun Special Cable Co., Ltd.\">\n<link rel=\"canonical\" href=\"https:\/\/feichuncables.com\/blog\/indonesia-coal-type260-type275\/\">\n<link rel=\"preconnect\" href=\"https:\/\/fonts.googleapis.com\">\n<link rel=\"preconnect\" href=\"https:\/\/fonts.gstatic.com\" crossorigin>\n<link href=\"https:\/\/fonts.googleapis.com\/css2?family=Source+Serif+4:ital,wght@0,400;0,600;0,700;0,800;1,400&#038;family=Instrument+Sans:wght@400;500;600;700&#038;family=IBM+Plex+Mono:wght@400;500&#038;display=swap\" rel=\"stylesheet\">\n<style>:root{color-scheme:light dark;--bg-body:#F5F3EE;--bg-surface:#FFFFFF;--bg-recessed:#EDEAE4;--bg-code:#F0EDE7;--bg-th:#1C1C1C;--bg-tr-alt:#F8F6F2;--bg-callout-blue:#EBF3FD;--bg-callout-amber:#FFF8E6;--bg-callout-green:#E9F7EF;--c-body:#222222;--c-secondary:#4D4D4D;--c-tertiary:#777777;--c-inverse:#FFFFFF;--c-cn:#666666;--c-link:#9B5A12;--c-link-hover:#734210;--c-accent:#B8860B;--b-rule:#D8D5CE;--b-light:#E8E5DF;--b-accent:#B8860B;--b-table:#CBC8C1;--sh-sm:0 1px 2px rgba(0,0,0,0.05);--sh-md:0 3px 10px rgba(0,0,0,0.07);--sh-table:0 1px 4px rgba(0,0,0,0.06);--badge-bg:#1C1C1C;--badge-c:#FFFFFF;--hl-green:#E1F5E6;--hl-red:#FDE8E1;}@media(prefers-color-scheme:dark){:root{--bg-body:#111111;--bg-surface:#1A1A1A;--bg-recessed:#222222;--bg-code:#252525;--bg-th:#282828;--bg-tr-alt:#161616;--bg-callout-blue:#162030;--bg-callout-amber:#25200E;--bg-callout-green:#142218;--c-body:#E2E0DB;--c-secondary:#ADABA6;--c-tertiary:#888683;--c-inverse:#111111;--c-cn:#908E89;--c-link:#D9A63E;--c-link-hover:#EDC462;--c-accent:#D9A63E;--b-rule:#333333;--b-light:#2A2A2A;--b-accent:#D9A63E;--b-table:#363636;--sh-sm:0 1px 2px rgba(0,0,0,0.25);--sh-md:0 3px 10px rgba(0,0,0,0.35);--sh-table:0 1px 4px rgba(0,0,0,0.3);--badge-bg:#D9A63E;--badge-c:#111111;--hl-green:#16291A;--hl-red:#2A1714;}}*,*::before,*::after{box-sizing:border-box;margin:0;padding:0}html{font-size:16px;scroll-behavior:smooth}body{font-family:'Instrument Sans',-apple-system,BlinkMacSystemFont,sans-serif;background:var(--bg-body);color:var(--c-body);line-height:1.8;overflow-x:hidden}.page-wrap{max-width:880px;margin:0 auto;padding:2.5rem 1.25rem 4rem;width:100%;overflow-x:hidden}.hdr{padding-bottom:2rem;margin-bottom:2.5rem;border-bottom:2px solid var(--b-accent)}.hdr .badge{display:inline-block;background:var(--badge-bg);color:var(--badge-c);font-size:.68rem;font-weight:700;letter-spacing:.12em;text-transform:uppercase;padding:.3em 1em;border-radius:2px;margin-bottom:1rem}.hdr h1{font-family:'Source Serif 4',Georgia,serif;font-weight:800;font-size:clamp(1.55rem,3.8vw,2.25rem);line-height:1.22;color:var(--c-body);margin-bottom:.65rem;word-wrap:break-word;overflow-wrap:break-word}.hdr .sub{font-size:1rem;color:var(--c-secondary);line-height:1.6;margin-bottom:.4rem;word-wrap:break-word;overflow-wrap:break-word}.hdr .sub-cn{font-size:.85rem;color:var(--c-cn);line-height:1.6;font-style:italic;word-wrap:break-word;overflow-wrap:break-word}.meta{display:flex;flex-wrap:wrap;gap:1rem;margin-top:1.1rem;font-size:.78rem;color:var(--c-tertiary)}.toc{background:var(--bg-surface);border:1px solid var(--b-rule);border-radius:4px;padding:1.2rem 1.4rem;margin-bottom:2.8rem;box-shadow:var(--sh-sm);overflow-x:hidden}.toc-label{font-weight:700;font-size:.72rem;letter-spacing:.1em;text-transform:uppercase;color:var(--c-tertiary);margin-bottom:.55rem}.toc ol{list-style:none;counter-reset:tc;padding:0}.toc li{counter-increment:tc;margin-bottom:.25rem}.toc li::before{content:counter(tc) \".\";font-weight:600;font-family:'IBM Plex Mono',monospace;font-size:.78rem;margin-right:.45em;color:var(--c-tertiary)}.toc a{font-size:.86rem;color:var(--c-secondary);text-decoration:none}.toc a:hover{color:var(--c-link);text-decoration:underline}.body h2{font-family:'Instrument Sans',sans-serif;font-weight:700;font-size:1.32rem;color:var(--c-body);margin:2.8rem 0 .9rem;padding-bottom:.35rem;border-bottom:1px solid var(--b-light)}.body h3{font-weight:600;font-size:1.05rem;color:var(--c-body);margin:1.7rem 0 .55rem}.body p{margin-bottom:1.15rem;color:var(--c-secondary);word-wrap:break-word;overflow-wrap:break-word}.body .cn{font-size:.84rem;color:var(--c-cn);margin-top:-.55rem;margin-bottom:1.15rem;padding-left:1rem;border-left:2px solid var(--b-light);font-style:italic}.body a{color:var(--c-link);text-decoration:underline;text-underline-offset:2px}.body a:hover{color:var(--c-link-hover)}.body strong{font-weight:600;color:var(--c-body)}.tw{width:100%;overflow-x:auto;margin:1.4rem 0 2rem;border:1px solid var(--b-table);border-radius:4px;box-shadow:var(--sh-table)}.tw table{width:100%;border-collapse:collapse;font-size:.86rem;line-height:1.5;word-wrap:break-word}.tw caption{text-align:left;font-weight:600;font-size:.78rem;letter-spacing:.04em;text-transform:uppercase;color:var(--c-tertiary);padding:.75rem 1rem .35rem;background:var(--bg-surface);border-bottom:1px solid var(--b-light)}.tw thead th{background:var(--bg-th);color:var(--c-inverse);font-weight:600;font-size:.76rem;letter-spacing:.03em;text-transform:uppercase;padding:.65rem 1rem;text-align:left;white-space:normal;border-bottom:2px solid var(--b-accent)}.tw tbody td{padding:.55rem 1rem;border-bottom:1px solid var(--b-light);color:var(--c-secondary);vertical-align:top;word-wrap:break-word;overflow-wrap:break-word}.tw tbody tr:nth-child(even){background:var(--bg-tr-alt)}.tw tbody tr:hover{background:var(--bg-callout-amber)}.tw tbody td:first-child{font-weight:500;color:var(--c-body)}.tw .g{background:var(--hl-green)}.tw .r{background:var(--hl-red)}.note{padding:1rem 1.2rem;margin:1.5rem 0;border-radius:0 4px 4px 0;font-size:.9rem;border-left:3px solid var(--b-accent)}.note.blue{background:var(--bg-callout-blue)}.note.amber{background:var(--bg-callout-amber)}.note.green{background:var(--bg-callout-green)}.note .nt{font-weight:700;font-size:.78rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-body);margin-bottom:.3rem}.note p{margin-bottom:.35rem}.refs{margin-top:2.8rem;padding-top:1.5rem;border-top:2px solid var(--b-rule)}.refs h2{font-size:1.08rem;margin-bottom:.9rem}.rl{list-style:none;counter-reset:rf;padding:0}.rl li{counter-increment:rf;font-size:.8rem;color:var(--c-tertiary);margin-bottom:.55rem;padding-left:2.2rem;position:relative;line-height:1.5;word-wrap:break-word;overflow-wrap:break-word}.rl li::before{content:\"[\" counter(rf) \"]\";position:absolute;left:0;font-weight:600;color:var(--c-secondary);font-family:'IBM Plex Mono',monospace;font-size:.75rem}.rl a{color:var(--c-link);word-break:break-all}.contact{background:var(--bg-recessed);border:1px solid var(--b-rule);border-radius:4px;padding:1.5rem;margin-top:2.5rem}.contact h3{font-size:.98rem;margin-bottom:.7rem;color:var(--c-body)}.cg{display:grid;grid-template-columns:repeat(auto-fit,minmax(210px,1fr));gap:.75rem}.ci{font-size:.83rem;color:var(--c-secondary);line-height:1.45;word-wrap:break-word;overflow-wrap:break-word}.ci .lb{font-weight:600;font-size:.7rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-tertiary);display:block;margin-bottom:.1rem}.ci a{color:var(--c-link);text-decoration:none}.ci a:hover{text-decoration:underline}.ft{margin-top:2rem;padding-top:1.5rem;border-top:1px solid var(--b-light);font-size:.75rem;color:var(--c-tertiary);text-align:center;line-height:1.55;word-wrap:break-word;overflow-wrap:break-word}@media(max-width:600px){.page-wrap{padding:1.2rem 1rem 3rem}.hdr h1{font-size:1.35rem}.tw{font-size:.8rem;width:100%;overflow-x:auto}.cg{grid-template-columns:1fr}}<\/style>\n<\/head>\n\n<body>\n<article class=\"page-wrap\" itemscope itemtype=\"https:\/\/schema.org\/TechArticle\">\n\n  <header class=\"hdr\">\n    <span class=\"badge\">Feichun Special Cable \u2014 Technical Blog<\/span>\n    <h1 itemprop=\"headline\">Indonesian Coal Contractors: Type 260 vs Type 275\u2014Critical Clarification for Drop-in Shuttle Car Cable Equivalents<\/h1>\n    <p class=\"sub\">Critical Engineering Clarification: Why Type 260 is NOT a Shuttle Car Cable. Deep Analysis of AS\/NZS 1802 Type 260 (Pliable Armoured Feeder) vs Type 275 (Shuttle Car Reeling). Olex Equivalent Sourcing for Indonesia Contractors (PAMA, BUMA, Thiess). Local Suppliers: Jembo Cable, Prysmian Batam, AS\/NZS-Certified Alternatives. Complete Technical Specifications and Replacement Strategy.<\/p>\n    <p class=\"sub-cn\">\u5173\u952e\u5de5\u7a0b\u6f84\u6e05\uff1a\u4e3a\u4ec0\u4e48Type 260\u4e0d\u662f\u7a7f\u68ad\u8f66\u7535\u7f06\u3002AS\/NZS 1802 Type 260\uff08\u67d4\u6027\u94e0\u88c5\u9988\u7535\uff09vs Type 275\uff08\u7a7f\u68ad\u8f66\u5377\u7ed5\uff09\u6df1\u5ea6\u5206\u6790\u3002\u5370\u5c3c\u627f\u5305\u5546(PAMA\u3001BUMA\u3001Thiess)\u7684Olex\u7b49\u6548\u54c1\u91c7\u8d2d\u3002\u672c\u5730\u4f9b\u5e94\u5546\uff1aJembo Cable\u3001Prysmian Batam\u3001AS\/NZS\u8ba4\u8bc1\u66ff\u4ee3\u54c1\u3002\u5b8c\u6574\u6280\u672f\u89c4\u683c\u548c\u66ff\u6362\u7b56\u7565\u3002<\/p>\n    <div class=\"meta\">\n      <span itemprop=\"author\" itemscope itemtype=\"https:\/\/schema.org\/Organization\"><span itemprop=\"name\">Anhui Feichun Special Cable Co., Ltd.<\/span><\/span>\n      <span>|<\/span>\n      <time itemprop=\"datePublished\" datetime=\"2026-03-06\">Mar 06, 2026<\/time>\n      <span>|<\/span>\n      <span>Reading time: ~38 min<\/span>\n    <\/div>\n  <\/header>\n\n  <nav class=\"toc\">\n    <div class=\"toc-label\">Contents<\/div>\n    <ol>\n      <li><a href=\"#s1\">\ud83d\udea8 CRITICAL CLARIFICATION: Type 260 is NOT a Shuttle Car Cable<\/a><\/li>\n      <li><a href=\"#s2\">Type 260: Pliable Armoured Feeder Cable\u2014True Applications<\/a><\/li>\n      <li><a href=\"#s3\">Type 275: The CORRECT Shuttle Car Cable Design<\/a><\/li>\n      <li><a href=\"#s4\">Physical Dimension Mismatch: Why Type 260 Cannot Fit Shuttle Car Reels<\/a><\/li>\n      <li><a href=\"#s5\">Complete Specification: Type 260 1.1\/1.1kV 3x35mm\u00b2 Armoured Feeder<\/a><\/li>\n      <li><a href=\"#s6\">Complete Specification: Type 275 1.1\/1.1kV 3x35mm\u00b2 Shuttle Car Cable<\/a><\/li>\n      <li><a href=\"#s7\">Structural Differences: Armoured vs Reinforced Design Physics<\/a><\/li>\n      <li><a href=\"#s8\">Failure Mode Analysis: What Happens When Type 260 is Forced onto Shuttle Car<\/a><\/li>\n      <li><a href=\"#s9\">Indonesian Local Sourcing: Approved Alternatives to Olex (Nexans)<\/a><\/li>\n      <li><a href=\"#s10\">Procurement Compliance Checklist for Indonesia Contractors<\/a><\/li>\n      <li><a href=\"#s11\">Cost-Benefit Analysis: Local Alternatives vs Imported Olex<\/a><\/li>\n      <li><a href=\"#s12\">Conclusion: Correct Cable Selection for Contractor Applications<\/a><\/li>\n    <\/ol>\n  <\/nav>\n\n  <div class=\"body\" itemprop=\"articleBody\">\n\n    <h2 id=\"s1\">\ud83d\udea8 CRITICAL CLARIFICATION: Type 260 is NOT a Shuttle Car Cable<\/h2>\n\n    <p><strong>The Dangerous Misconception:<\/strong> When Indonesian coal contractors (PAMA, BUMA, Thiess Indonesia) begin sourcing cable replacements for aging Olex (Nexans) systems, there is a common but catastrophic confusion: conflating Type 260 (pliable armoured feeder cable) with shuttle car trailing cables. This error, if executed in procurement, will result in: (1) Physical incompatibility with shuttle car reels, (2) Equipment damage within days of deployment, (3) Potential explosive electrical failures underground, (4) Massive operational downtime and safety hazards.<\/p>\n\n    <p class=\"cn\">\u5f53\u5370\u5c3c\u7164\u77ff\u627f\u5305\u5546(PAMA\u3001BUMA\u3001Thiess Indonesia)\u5f00\u59cb\u91c7\u8d2d\u8001\u5316\u7684Olex (Nexans)\u7cfb\u7edf\u7684\u7535\u7f06\u66ff\u6362\u4ef6\u65f6\uff0c\u5b58\u5728\u4e00\u4e2a\u5e38\u89c1\u4f46\u707e\u96be\u6027\u7684\u6df7\u6dc6\uff1a\u5c06Type 260\uff08\u67d4\u6027\u94e0\u88c5\u9988\u7535\u7535\u7f06\uff09\u4e0e\u7a7f\u68ad\u8f66\u62d6\u66f3\u7535\u7f06\u6df7\u4e3a\u4e00\u8c08\u3002\u5982\u679c\u8fd9\u4e2a\u9519\u8bef\u5728\u91c7\u8d2d\u4e2d\u6267\u884c\uff0c\u5c06\u5bfc\u81f4\uff1a(1)\u4e0e\u7a7f\u68ad\u8f66\u6536\u5377\u9f13\u7684\u7269\u7406\u4e0d\u517c\u5bb9\uff0c(2)\u90e8\u7f72\u51e0\u5929\u5185\u8bbe\u5907\u635f\u574f\uff0c(3)\u5730\u4e0b\u6f5c\u5728\u7206\u70b8\u6027\u7535\u6c14\u6545\u969c\uff0c(4)\u5927\u89c4\u6a21\u8fd0\u8425\u505c\u673a\u548c\u5b89\u5168\u9690\u60a3\u3002<\/p>\n\n    <p><strong>The Core Error:<\/strong> Type 260 contains a heavy pliable galvanized steel wire armour layer. This armour is engineered for semi-fixed installation where cables power underground pump stations, mobile substations, or open-pit mining equipment from stationary or slowly repositioned feed points. It is explicitly NOT designed for high-frequency reeling and dynamic coiling on shuttle car drums, which require thousands of wind-unwind cycles.<\/p>\n\n    <h2 id=\"s2\">2. Type 260: Pliable Armoured Feeder Cable\u2014True Applications<\/h2>\n\n    <p><strong>Design Purpose:<\/strong> Type 260 is the AS\/NZS 1802 designation for a flexible cable featuring a protective galvanized steel wire armour layer. The term &#8220;pliable&#8221; refers to the flexibility of the armour\u2014it bends to accommodate cable routing around underground infrastructure, but it is NOT intended for rapid reeling cycles.<\/p>\n\n    <p><strong>Legitimate Applications for Type 260:<\/strong> (1) Underground mine pump station power\u2014cables remain relatively static once installed, (2) Mobile\/transportable substations\u2014repositioned occasionally but not continuously, (3) Open-pit mining feeder cables\u2014routed to fixed or semi-fixed equipment locations, (4) Tunnel boring machine (TBM) power supplies\u2014deployed once per boring section, (5) Mining equipment (draglines, shovels) requiring robust impact protection rather than high flexibility.<\/p>\n\n    <p><strong>The Armour Purpose:<\/strong> The steel wire armour is designed to protect against falling objects, rockfall impact, and accidental damage from mining equipment. It is NOT designed to withstand the torsional, bending, and tensile stresses of continuous drum reeling.<\/p>\n\n    <h2 id=\"s3\">3. Type 275: The CORRECT Shuttle Car Cable Design<\/h2>\n\n    <p><strong>Shuttle Car Operating Reality:<\/strong> A shuttle car in an underground coal mine is a vehicle that continuously: (1) Moves loaded ore\/waste from the mining face to a dump point, (2) Reels out trailing cable as it advances forward, (3) Reels back cable as it returns to the face, (4) Repeats this cycle 50\u2013100+ times per day. Each cycle involves coiling the cable tightly on the car&#8217;s powered drum, applying significant mechanical and thermal stress.<\/p>\n\n    <p><strong>Type 275 Design for This Duty:<\/strong> Type 275 eliminates the metal armour entirely. Instead, it uses: (1) High-strength open-weave fiber reinforcement braid for tensile strength, (2) Semiconductive PCP filling between conductors to provide abrasion resistance, (3) Extremely flexible insulation and sheath formulation optimized for repeated bending, (4) Class 5 tinned copper conductors for oxidation resistance during frequent flexing.<\/p>\n\n    <h2 id=\"s4\">4. Physical Dimension Mismatch: Why Type 260 Cannot Fit Shuttle Car Reels<\/h2>\n\n    <p><strong>Outer Diameter Comparison:<\/strong><\/p>\n\n    <p>Type 260 3\u00d735mm\u00b2: OD 65\u201368 mm, Weight ~7.6\u20137.8 tonnes per km<\/p>\n\n    <p>Type 275 3\u00d735mm\u00b2: OD 38\u201342 mm, Weight ~2.6 tonnes per km<\/p>\n\n    <p><strong>The Physics Problem:<\/strong> Shuttle car reels are engineered with specific drum diameters and width constraints. A standard shuttle car reel might accommodate 500\u20131,000 meters of Type 275 cable (3\u00d735mm\u00b2 at 40 mm OD). The same reel attempting to spool Type 260 (65 mm OD) would fit only 200\u2013300 meters before filling the drum width\u2014insufficient for underground mine haul distances.<\/p>\n\n    <p><strong>Mechanical Consequence:<\/strong> If forced onto a shuttle car designed for Type 275, the Type 260&#8217;s heavier profile and larger diameter create excessive radial pressure on the reel drum, stressing motor bearings and potentially causing motor overload. More critically, the tight coiling of armoured cable creates stress concentrations where the steel wire armour bends sharply, initiating fractures in the wire itself.<\/p>\n\n    <h2 id=\"s5\">5. Complete Specification: Type 260 1.1\/1.1kV 3x35mm\u00b2 Armoured Feeder<\/h2>\n\n    <div class=\"tw\">\n      <caption>Table 1 \u2014 AS\/NZS 1802 Type 260 1.1\/1.1kV 3\u00d735mm\u00b2 Pliable Armoured Feeder Specification<\/caption>\n      <table>\n        <thead>\n          <tr>\n            <th>Parameter<\/th>\n            <th>Specification<\/th>\n            <th>Unit<\/th>\n            <th>Notes<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td><strong>Conductor Configuration<\/strong><\/td>\n            <td class=\"r\">3\u00d735mm\u00b2 + 3 pilot<\/td>\n            <td>\u2014<\/td>\n            <td>Power cores + interstitial earth conductors<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Conductor Material<\/strong><\/td>\n            <td class=\"r\">Tinned copper Class 5<\/td>\n            <td>\u2014<\/td>\n            <td>Flexible stranded, oxidation-resistant<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Insulation<\/strong><\/td>\n            <td class=\"r\">EPR (Type R-EP-90)<\/td>\n            <td>\u2014<\/td>\n            <td>~1.6mm thickness, AS\/NZS 3808 compliant<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Armour (KEY FEATURE)<\/strong><\/td>\n            <td class=\"g\">Pliable galvanized steel wire<\/td>\n            <td>\u2014<\/td>\n            <td>This distinguishes Type 260 from Type 275<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Inner Sheath<\/strong><\/td>\n            <td class=\"r\">PCP (heavy-duty chloroprene)<\/td>\n            <td>\u2014<\/td>\n            <td>Cushioning layer between conductors and armour<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Outer Sheath<\/strong><\/td>\n            <td class=\"r\">Heavy-duty PCP\/CPE elastomer<\/td>\n            <td>\u2014<\/td>\n            <td>Oil-resistant, flame-retardant, abrasion-resistant<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Outer Diameter<\/strong><\/td>\n            <td class=\"r\">65\u201368<\/td>\n            <td>mm<\/td>\n            <td>LARGE\u2014cannot fit standard shuttle car reels<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Copper Weight<\/strong><\/td>\n            <td class=\"r\">~1,250<\/td>\n            <td>kg\/km<\/td>\n            <td>Power + earth + pilot cores<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Total Weight<\/strong><\/td>\n            <td class=\"r\">~7,600\u20137,800<\/td>\n            <td>kg\/km<\/td>\n            <td>Very heavy\u2014armour adds ~80% weight<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Ampacity @ 40\u00b0C<\/strong><\/td>\n            <td class=\"r\">~135<\/td>\n            <td>A<\/td>\n            <td>Per AS\/NZS 3008<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Min Bending Radius<\/strong><\/td>\n            <td class=\"r\">~480<\/td>\n            <td>mm<\/td>\n            <td>Dynamic stress acceptable only for non-reeling use<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Standards<\/strong><\/td>\n            <td class=\"r\">AS\/NZS 1802, AS\/NZS 1125<\/td>\n            <td>\u2014<\/td>\n            <td>Mining-specific compliance<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <h2 id=\"s6\">6. Complete Specification: Type 275 1.1\/1.1kV 3x35mm\u00b2 Shuttle Car Cable<\/h2>\n\n    <div class=\"tw\">\n      <caption>Table 2 \u2014 AS\/NZS 1802 Type 275 1.1\/1.1kV 3\u00d735mm\u00b2 Shuttle Car Reeling Cable Specification<\/caption>\n      <table>\n        <thead>\n          <tr>\n            <th>Parameter<\/th>\n            <th>Specification<\/th>\n            <th>Unit<\/th>\n            <th>Notes<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td><strong>Conductor Configuration<\/strong><\/td>\n            <td class=\"g\">3\u00d735mm\u00b2 + 3\u00d7(35\/3) + 1\u00d716 pilot<\/td>\n            <td>\u2014<\/td>\n            <td>Power + interstitial earth + extensible pilot<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Conductor Material<\/strong><\/td>\n            <td class=\"g\">Tinned copper Class 5<\/td>\n            <td>\u2014<\/td>\n            <td>Highly flexible stranded, oxidation-resistant<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Insulation<\/strong><\/td>\n            <td class=\"g\">EPR (Type R-EP-90)<\/td>\n            <td>\u2014<\/td>\n            <td>~2.0mm thickness, superior flexibility vs Type 260<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Armour (NOT PRESENT)<\/strong><\/td>\n            <td class=\"g\">None\u2014replaced by reinforcement<\/td>\n            <td>\u2014<\/td>\n            <td>This is the FUNDAMENTAL difference<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Reinforcement (KEY FEATURE)<\/strong><\/td>\n            <td class=\"g\">Open-weave high-strength fiber braid<\/td>\n            <td>\u2014<\/td>\n            <td>Provides tensile strength without metal rigidity<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Semiconductive Filling<\/strong><\/td>\n            <td class=\"g\">PCP-based, ~1.0 \u03a9.m resistivity<\/td>\n            <td>\u2014<\/td>\n            <td>Electrical field uniformity + abrasion resistance<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Outer Sheath<\/strong><\/td>\n            <td class=\"g\">Heavy-duty PCP\/CPE elastomer<\/td>\n            <td>\u2014<\/td>\n            <td>Oil-resistant, flame-retardant, impact-resistant<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Outer Diameter<\/strong><\/td>\n            <td class=\"g\">38\u201342<\/td>\n            <td>mm<\/td>\n            <td>SMALL\u2014designed for shuttle car reel fit<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Copper Weight<\/strong><\/td>\n            <td class=\"g\">~1,180<\/td>\n            <td>kg\/km<\/td>\n            <td>Similar conductor content, no armour<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Total Weight<\/strong><\/td>\n            <td class=\"g\">~2,600<\/td>\n            <td>kg\/km<\/td>\n            <td>ONE-THIRD of Type 260 weight<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Ampacity @ 40\u00b0C<\/strong><\/td>\n            <td class=\"g\">~128<\/td>\n            <td>A<\/td>\n            <td>Comparable to Type 260 despite no armour<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Tensile Strength<\/strong><\/td>\n            <td class=\"g\">~20 N\/mm\u00b2 (conductor basis)<\/td>\n            <td>\u2014<\/td>\n            <td>Sufficient for continuous reel stress<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Min Bending Radius<\/strong><\/td>\n            <td class=\"g\">~300<\/td>\n            <td>mm<\/td>\n            <td>Much more flexible than Type 260\u2014designed for reeling<\/td>\n          <\/tr>\n          <tr>\n            <td><strong>Standards<\/strong><\/td>\n            <td class=\"g\">AS\/NZS 1802, AS\/NZS 1125<\/td>\n            <td>\u2014<\/td>\n            <td>Mining-specific compliance<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <h2 id=\"s7\">7. Structural Differences: Armoured vs Reinforced Design Physics<\/h2>\n\n    <p><strong>Armoured (Type 260) Design Philosophy:<\/strong> Metal armour provides point-load impact protection. When a heavy object strikes the cable, the steel wire distributes the impact force over a localized area, protecting the insulation underneath. This is optimal for static or semi-static installations where the cable experiences occasional impacts but not continuous flexing.<\/p>\n\n    <p><strong>Reinforced (Type 275) Design Philosophy:<\/strong> Open-weave braid provides tensile strength without the rigidity of metal. The fibers work in concert with the elastomer sheath to distribute stress evenly across the cable circumference during bending. This is optimal for dynamic reeling where the cable experiences thousands of bend cycles and tensile loading.<\/p>\n\n    <p><strong>Incompatibility at the Molecular Level:<\/strong> When Type 260&#8217;s galvanized steel armour is forced to bend sharply (as required by shuttle car drum reeling), the wire experiences localized stress concentrations. At bending radii <500 mm (common in tight reels), the wire develops fatigue cracks. Once cracked, water ingress accelerates, and the armour corrodes from the inside, eventually penetrating the insulation and causing catastrophic electrical failure.<\/p>\n\n    <h2 id=\"s8\">8. Failure Mode Analysis: What Happens When Type 260 is Forced onto Shuttle Car<\/h2>\n\n    <p><strong>Failure Sequence (Days 1\u20137):<\/strong> Type 260 is installed on shuttle car. The cable&#8217;s larger diameter (65\u201368 mm) requires tighter coiling on the reel to fit required cable length. Bending radius drops to ~400 mm\u2014below the 480 mm minimum for Type 260 armoured cable.<\/p>\n\n    <p><strong>Failure Sequence (Days 8\u201330):<\/strong> Repeated coiling-uncoiling cycles (50+ per day) subject the galvanized steel wire armour to cyclic bending stress. At each bend location, tiny fatigue cracks initiate in the wire surface. The PCP inner sheath, designed for armoured cables, provides minimal cushioning against the sharp bends.<\/p>\n\n    <p><strong>Failure Sequence (Days 31\u201390):<\/strong> Fatigue cracks propagate through the armour wire thickness. Water from underground moisture, mine water contact, or humidity infiltrates the cracked armour. Galvanic corrosion begins between the steel wire and the copper conductors. Corrosion products expand, creating internal pressure and further damaging the insulation.<\/p>\n\n    <p><strong>Failure Sequence (Days 91\u2013180):<\/strong> Insulation resistance drops from >100 M\u03a9 to <10 M\u03a9. Pilot core resistance shows increasing faults. Earth continuity relay becomes unreliable. Within weeks, partial discharge begins. The cable becomes a fire\/explosion hazard underground.<\/p>\n\n    <p><strong>Final Failure (Day ~180\u2013365):<\/strong> Phase-to-earth or phase-to-phase short circuit occurs. Massive arc energy is released in the confined underground shuttle car zone. Risk of methane or coal dust ignition. Equipment destroyed. Mine operations halted. Personnel at serious risk.<\/p>\n\n    <h2 id=\"s9\">9. Indonesian Local Sourcing: Approved Alternatives to Olex (Nexans)<\/h2>\n\n    <p><strong>Quality Indonesian Suppliers with AS\/NZS 1802 Certification:<\/strong><\/p>\n\n    <p><strong>Jembo Cable (PT Jembo Cable Company Tbk):<\/strong> Large Indonesian cable manufacturer with ISO 9001 and AS\/NZS 1802 third-party testing. Produces both Type 260 armoured feeder and Type 275 shuttle car cables. Pricing typically 20\u201330% below Olex (Nexans). Lead time 8\u201310 weeks.<\/p>\n\n    <p><strong>Prysmian Batam (Prysmian Group, Batam Island facility):<\/strong> Multinational manufacturer with regional Indonesia production. Full AS\/NZS 1802 compliance and NATA accreditation. Premium quality, pricing 10\u201315% below Olex. Lead time 6\u20138 weeks.<\/p>\n\n    <p><strong>Chinese Manufacturers with AS\/NZS 1802 Certification (via Feichun and others):<\/strong> Several Chinese manufacturers hold legitimate AS\/NZS 1802 third-party test reports. Pricing 35\u201345% below Olex. Lead time 10\u201314 weeks. Requires careful supplier vetting and reference checking.<\/p>\n\n    <div class=\"note amber\">\n      <div class=\"nt\">Critical Procurement Rule for Indonesia<\/div>\n      <p><strong>MANDATORY COMPLIANCE:<\/strong> Any cable supplier claiming AS\/NZS 1802 compliance MUST provide a certified third-party test report from an accredited testing laboratory (e.g., NATA in Australia, or equivalent). Do not accept manufacturer self-certification alone. Request: (1) Third-party test report, (2) Pilot core continuity test data, (3) Tensile strength certificate, (4) Insulation resistance measurement baseline.<\/p>\n    <\/div>\n\n    <h2 id=\"s10\">10. Procurement Compliance Checklist for Indonesia Contractors<\/h2>\n\n    <p><strong>Step 1\u2014Correctly Identify Cable Type:<\/strong> Confirm whether you need Type 260 (fixed\/semi-fixed feeder) or Type 275 (shuttle car reeling). If this question cannot be answered definitively, contact the equipment manufacturer (Joy Global, Sandvik, etc.) for cable specification.<\/p>\n\n    <p><strong>Step 2\u2014Obtain Specification From OEM:<\/strong> Request from equipment supplier (Olex originally) the exact cable specification: voltage, conductor size, outer diameter, ampacity, bending radius. Do NOT assume &#8220;Type 275 equivalent&#8221; is acceptable without matching all parameters.<\/p>\n\n    <p><strong>Step 3\u2014Verify Local Supplier Credentials:<\/strong> For Indonesia-based sourcing: Request ISO 9001 certificate, AS\/NZS 1802 third-party test report, NATA accreditation (if Australian testing), and references from other mining operations using their cables.<\/p>\n\n    <p><strong>Step 4\u2014Specification Comparison Matrix:<\/strong> Create detailed comparison of Olex cable specifications vs proposed replacement, parameter-by-parameter. Do not approve any cable where outer diameter differs by >5%, ampacity differs by >10%, or bending radius specifications diverge.<\/p>\n\n    <p><strong>Step 5\u2014Sample Testing:<\/strong> For first-time supplier relationships, request delivery of one cable drum for internal testing: outer diameter measurement, insulation resistance baseline (megohm meter at 1 kV for 1 minute), tensile strength sample test.<\/p>\n\n    <h2 id=\"s11\">11. Cost-Benefit Analysis: Local Alternatives vs Imported Olex<\/h2>\n\n    <p><strong>Olex (Nexans) Pricing Baseline:<\/strong> Type 275 3\u00d735mm\u00b2 shuttle car cable: ~$3.50\u20134.50 USD per meter (or ~$3,500\u20134,500 USD per 1,000 meter drum). Lead time: 12\u201316 weeks. Supply vulnerability: single-source dependency, price fluctuation exposure.<\/p>\n\n    <p><strong>Jembo Cable (Indonesia) Equivalent:<\/strong> ~$2.50\u20133.00 USD per meter (~$2,500\u20133,000 per drum). Lead time: 8\u201310 weeks. Supply reliability: domestic manufacturer, lower logistics cost, faster local support.<\/p>\n\n    <p><strong>Prysmian Batam Equivalent:<\/strong> ~$3.00\u20133.50 USD per meter (~$3,000\u20133,500 per drum). Lead time: 6\u20138 weeks. Supply reliability: multinational backing, quality assurance, regional logistics efficiency.<\/p>\n\n    <p><strong>Feichun (Chinese + Indonesian Partners) Equivalent:<\/strong> ~$2.00\u20132.75 USD per meter (~$2,000\u20132,750 per drum). Lead time: 10\u201314 weeks. Supply reliability: requires detailed supplier audit, reference checking essential.<\/p>\n\n    <p><strong>Annual Cost Savings Example:<\/strong> Large Indonesian coal contractor (PAMA, BUMA, Thiess) replacing 50,000 meters of shuttle car cable annually: Olex cost ~$175,000\u2013225,000 USD. Jembo equivalent ~$125,000\u2013150,000 USD. Annual savings: ~$50,000\u201375,000 USD. Over 5-year equipment lifecycle, cumulative savings approach $250,000\u2013375,000 USD.<\/p>\n\n    <h2 id=\"s12\">12. Conclusion: Correct Cable Selection for Contractor Applications<\/h2>\n\n    <p><strong>Summary\u2014The Essential Distinction:<\/strong> Type 260 = pliable armoured feeder cable for pump stations, mobile substations, semi-fixed underground equipment. Type 275 = shuttle car reeling cable for high-frequency dynamic deployment. Never confuse these designations or attempt physical substitution.<\/p>\n\n    <p><strong>For Indonesian Coal Contractors:<\/strong> When sourcing Olex (Nexans) replacement cables, confirm the application (shuttle car vs fixed feeder), validate supplier AS\/NZS 1802 certification with third-party test reports, and compare specifications parameter-by-parameter. Local Indonesian suppliers (Jembo, Prysmian Batam) offer substantial cost savings (20\u201330%) while maintaining compliance and supply reliability.<\/p>\n\n    <p>Feichun Special Cable provides AS\/NZS 1802-compliant Type 260 (armoured feeder) and Type 275 (shuttle car) cables with complete technical documentation and third-party testing for Indonesian mining contractor applications. Our technical team assists with cable selection clarification, specification matching, and certification verification to ensure correct application and regulatory compliance.<\/p>\n\n  <\/div>\n\n  <section class=\"refs\">\n    <h2>References &#038; Sources<\/h2>\n    <ol class=\"rl\">\n      <li>AS\/NZS 1802:2012, &#8220;Fixed electric cables\u2014General purpose cables for underground mining,&#8221; Standards New Zealand and Standards Australia.<\/li>\n      <li>AS\/NZS 1125:2015, &#8220;Electric cables\u2014Insulated and sheathed cables for rated voltages up to 3.3 kV,&#8221; Standards New Zealand and Standards Australia.<\/li>\n      <li>Feichun Special Cable Research &#038; Development Team, &#8220;Type 260 vs Type 275: Clarification and Specification Matching for Indonesian Mining Contractors,&#8221; Technical Report, 2025.<\/li>\n    <\/ol>\n  <\/section>\n\n  <div class=\"contact\">\n    <h3>Contact Anhui Feichun Special Cable Co., Ltd.<\/h3>\n    <div class=\"cg\">\n      <div class=\"ci\">\n        <span class=\"lb\">Type 260 &#038; Type 275 Cables<\/span>\n        <a href=\"mailto:tech@feichuncables.com\" rel=\"nofollow\">tech@feichuncables.com<\/a>\n      <\/div>\n      <div class=\"ci\">\n        <span class=\"lb\">Indonesian Mining Contractor Support<\/span>\n        <a href=\"mailto:mining@feichuncables.com\" rel=\"nofollow\">mining@feichuncables.com<\/a>\n      <\/div>\n      <div class=\"ci\">\n        <span class=\"lb\">Sales &#038; Technical Specifications<\/span>\n        <a href=\"mailto:sales@feichuncables.com\" rel=\"nofollow\">sales@feichuncables.com<\/a>\n      <\/div>\n      <div class=\"ci\">\n        <span class=\"lb\">WhatsApp \/ WeChat<\/span>\n        <a href=\"https:\/\/wa.me\/8613855123218\" rel=\"nofollow noopener\" target=\"_blank\">+86 138-5512-3218<\/a>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <footer class=\"ft\">\n    <p>&copy; 2026 Anhui Feichun Special Cable Co., Ltd. \u2014 All rights reserved.<\/p>\n    <p>Building A, Private Science &amp; Technology Park, Hefei Economic and Technological Development Zone, Anhui Province, China.<\/p>\n    <p><strong>SEO Keywords:<\/strong> Olex Type 260 equivalent, AS\/NZS 1802 Type 260, Type 260 vs Type 275, shuttle car cable Type 275, Indonesian coal mining cable, PAMA mining contractor cable, BUMA underground mining, Jembo mining cable, Prysmian Indonesia, pliable armoured cable 1.1kV, 3x35mm2 Type 260 specifications, Nexans drop-in replacement, AS\/NZS 1802 compliant cable, flexible feeder cable 1.1kV, armoured cable Indonesia, mining equipment power supply, continuous miner cable, heavy duty PCP sheath, EPR insulation mining cable, coal mine electrical standards, underground coal mine power, cable outer diameter specifications, mining cable copper weight, tensile strength mining cable, flame retardant rubber cable, AS\/NZS 3008 mining cable, mining cable current capacity, dynamic reeling vs fixed feeder, shuttle car electrical system, coal contractor equipment, underground substation cable, mining cable sourcing Southeast Asia, electrical engineering Indonesia mining, cable replacement strategy mining, drop-in replacement compliance, cable compliance testing, high mechanical stress cable, mining cable reliability, equipment downtime prevention, coal mine safety standards, AS\/NZS 1125 compliance.<\/p>\n  <\/footer>\n\n<\/article>\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"The Dangerous Misconception: When Indonesian coal contractors (PAMA, BUMA, Thiess Indonesia) begin sourcing cable replacements for aging Olex (Nexans) systems, there is a common but catastrophic confusion: conflating Type 260 (pliable armoured feeder cable) with shuttle car trailing cables. This error, if executed in procurement, will result in: (1) Physical incompatibility with shuttle car reels, (2) Equipment damage within days of deployment, (3) Potential explosive electrical failures underground, (4) Massive operational downtime and safety hazards.","protected":false},"author":1,"featured_media":8599,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[222,66],"tags":[46712,46731,46725,46720,37489,46735,35821,46718,46729,46596,46726,46115,1114,46723,5356,4342,45534,46734,46732,10990,46724,34717,892,46721,46713,46730,46727,837,46722,46119,46166,46728,46736,46711,46717,34718,46715,46719,2967,46739,46134,46714,46737,31316,766,46393,46716,46124,36944,46733],"class_list":["post-8598","post","type-post","status-publish","format-standard","has-post-thumbnail","category-as-nzs-1802-reeling-cables-for-underground-mining","category-common-problems-encountered-in-cable-applications","tag-1-1kv-3x35mm2-cable","tag-128a-mining-cable","tag-2-awg-mining-cable-equivalent","tag-35mm2-shuttle-car-trailing-cable","tag-as-nzs-1802-type-275","tag-as-nzs-3808-epr-insulation","tag-as-nzs-certified-mining-cable","tag-buma-mining-equipment","tag-cable-failure-prevention-underground","tag-cable-reel-drum-capacity","tag-cable-tensile-strength-mining","tag-central-extensible-pilot-core","tag-continuous-miner-cable","tag-drop-in-replacement-mining-cable","tag-dynamic-reeling-cable","tag-earth-continuity-monitoring","tag-elastomeric-trailing-cable","tag-electrical-engineering-mining-indonesia","tag-equipment-downtime-prevention","tag-flame-retardant-rubber-cable","tag-flexible-tinned-copper-cable","tag-heavy-duty-pcp-sheath","tag-high-mechanical-stress-cable","tag-indonesian-coal-contractor-cable","tag-jembo-mining-cable-alternative","tag-joy-shuttle-car-cable","tag-kaltim-prima-coal-underground","tag-low-voltage-trailing-cable","tag-mine-site-safety-standards","tag-mining-cable-copper-weight","tag-mining-electrical-compliance","tag-mining-infrastructure-procurement","tag-mining-operations-efficiency","tag-nexans-shuttle-car-cable-replacement","tag-olex-type-275-equivalent","tag-open-weave-braid-reinforcement","tag-pama-underground-mining","tag-prysmian-indonesia-as-nzs","tag-rubber-insulated-flexible-cable","tag-sandvik-mining-equipment-cable","tag-semiconductive-pcp-filling","tag-shuttle-car-cable-weight","tag-southeast-asia-cable-sourcing","tag-tear-resistant-mining-cable","tag-torsion-resistant-cable","tag-trailing-cable-outer-diameter","tag-type-260-vs-type-275","tag-type-275-shuttle-car-cable","tag-underground-coal-mine-power","tag-underground-feeder-replacement","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/8598","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=8598"}],"version-history":[{"count":2,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/8598\/revisions"}],"predecessor-version":[{"id":8601,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/8598\/revisions\/8601"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/8599"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=8598"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=8598"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=8598"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}