{"id":8551,"date":"2026-03-06T13:44:38","date_gmt":"2026-03-06T05:44:38","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=8551"},"modified":"2026-03-06T13:44:41","modified_gmt":"2026-03-06T05:44:41","slug":"as-nzs-1802-vs-as-nzs-1972-which-australian-standard-applies-to-your-underground-mining-equipment","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/as-nzs-1802-vs-as-nzs-1972-which-australian-standard-applies-to-your-underground-mining-equipment\/","title":{"rendered":"AS\/NZS 1802 vs AS\/NZS 1972: Which Australian Standard Applies to Your Underground Mining Equipment?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Complete Technical Guide: Understanding Mobile vs Fixed Mining Cable Standards. Equipment Mobility Determines Your Standard. Earth Continuity Monitoring Strategy. Technical Specification Comparison. Selection Guide for Coal Mine Engineers.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5b8c\u6574\u6280\u672f\u6307\u5357\uff1a\u7406\u89e3\u79fb\u52a8\u578b\u4e0e\u56fa\u5b9a\u578b\u91c7\u77ff\u7535\u7f06\u6807\u51c6\u3002\u8bbe\u5907\u79fb\u52a8\u6027\u51b3\u5b9a\u4e86\u9002\u7528\u6807\u51c6\u3002\u63a5\u5730\u8fde\u7eed\u6027\u76d1\u6d4b\u7b56\u7565\u3002\u6280\u672f\u89c4\u683c\u5bf9\u6bd4\u3002\u7164\u77ff\u5de5\u7a0b\u5e08\u9009\u578b\u6307\u5357\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-dominant-color=\"737374\" data-has-transparency=\"false\" style=\"--dominant-color: #737374;\" loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"579\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-975-1200x579.avif\" alt=\"\" class=\"wp-image-8552 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-975-1200x579.avif 1200w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-975-300x145.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-975-768x370.avif 768w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-975-1536x741.avif 1536w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-975-400x193.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-975-800x386.avif 800w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-975-832x401.avif 832w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-975-1664x802.avif 1664w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-975-1248x602.avif 1248w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-975.avif 1686w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n<title>AS\/NZS 1802 vs AS\/NZS 1972: Which Australian Standard Applies to Your Underground Mining Equipment | Feichun Cable<\/title>\n<meta name=\"description\" content=\"Complete technical guide: AS\/NZS 1802 vs AS\/NZS 1972 standards comparison for underground mining cables. Mobile trailing cables vs fixed feeder cables, technical specifications, earth continuity monitoring, compliance selection guide.\">\n<meta name=\"keywords\" content=\"AS\/NZS 1802, AS\/NZS 1972, underground mining cable standards, trailing cable, feeder cable, mobile mining equipment, fixed mining cable, SWA cable, pliable wire armour, earth continuity, mining electrical compliance, 3.3kV cable, 11kV cable, continuous miner cable, shuttle car cable, mining cable selection, coal mine electrical standards, Australian mining standards, Type 241, Type 3 cable, pilot core cable, semi-fixed mining equipment\">\n<meta name=\"author\" content=\"Anhui Feichun Special Cable Co., Ltd.\">\n<link rel=\"canonical\" href=\"https:\/\/feichuncables.com\/blog\/as-nzs-1802-vs-1972\/\">\n<link rel=\"preconnect\" href=\"https:\/\/fonts.googleapis.com\">\n<link rel=\"preconnect\" href=\"https:\/\/fonts.gstatic.com\" crossorigin>\n<link href=\"https:\/\/fonts.googleapis.com\/css2?family=Source+Serif+4:ital,wght@0,400;0,600;0,700;0,800;1,400&#038;family=Instrument+Sans:wght@400;500;600;700&#038;family=IBM+Plex+Mono:wght@400;500&#038;display=swap\" rel=\"stylesheet\">\n<style>:root{color-scheme:light dark;--bg-body:#F5F3EE;--bg-surface:#FFFFFF;--bg-recessed:#EDEAE4;--bg-code:#F0EDE7;--bg-th:#1C1C1C;--bg-tr-alt:#F8F6F2;--bg-callout-blue:#EBF3FD;--bg-callout-amber:#FFF8E6;--bg-callout-green:#E9F7EF;--c-body:#222222;--c-secondary:#4D4D4D;--c-tertiary:#777777;--c-inverse:#FFFFFF;--c-cn:#666666;--c-link:#9B5A12;--c-link-hover:#734210;--c-accent:#B8860B;--b-rule:#D8D5CE;--b-light:#E8E5DF;--b-accent:#B8860B;--b-table:#CBC8C1;--sh-sm:0 1px 2px rgba(0,0,0,0.05);--sh-md:0 3px 10px rgba(0,0,0,0.07);--sh-table:0 1px 4px rgba(0,0,0,0.06);--badge-bg:#1C1C1C;--badge-c:#FFFFFF;--hl-green:#E1F5E6;--hl-red:#FDE8E1;}@media(prefers-color-scheme:dark){:root{--bg-body:#111111;--bg-surface:#1A1A1A;--bg-recessed:#222222;--bg-code:#252525;--bg-th:#282828;--bg-tr-alt:#161616;--bg-callout-blue:#162030;--bg-callout-amber:#25200E;--bg-callout-green:#142218;--c-body:#E2E0DB;--c-secondary:#ADABA6;--c-tertiary:#888683;--c-inverse:#111111;--c-cn:#908E89;--c-link:#D9A63E;--c-link-hover:#EDC462;--c-accent:#D9A63E;--b-rule:#333333;--b-light:#2A2A2A;--b-accent:#D9A63E;--b-table:#363636;--sh-sm:0 1px 2px rgba(0,0,0,0.25);--sh-md:0 3px 10px rgba(0,0,0,0.35);--sh-table:0 1px 4px rgba(0,0,0,0.3);--badge-bg:#D9A63E;--badge-c:#111111;--hl-green:#16291A;--hl-red:#2A1714;}}*,*::before,*::after{box-sizing:border-box;margin:0;padding:0}html{font-size:16px;scroll-behavior:smooth}body{font-family:'Instrument Sans',-apple-system,BlinkMacSystemFont,sans-serif;background:var(--bg-body);color:var(--c-body);line-height:1.8}.page-wrap{max-width:880px;margin:0 auto;padding:2.5rem 1.25rem 4rem}.hdr{padding-bottom:2rem;margin-bottom:2.5rem;border-bottom:2px solid var(--b-accent)}.hdr .badge{display:inline-block;background:var(--badge-bg);color:var(--badge-c);font-size:.68rem;font-weight:700;letter-spacing:.12em;text-transform:uppercase;padding:.3em 1em;border-radius:2px;margin-bottom:1rem}.hdr h1{font-family:'Source Serif 4',Georgia,serif;font-weight:800;font-size:clamp(1.55rem,3.8vw,2.25rem);line-height:1.22;color:var(--c-body);margin-bottom:.65rem}.hdr .sub{font-size:1rem;color:var(--c-secondary);line-height:1.6;margin-bottom:.4rem}.hdr .sub-cn{font-size:.85rem;color:var(--c-cn);line-height:1.6;font-style:italic}.meta{display:flex;flex-wrap:wrap;gap:1rem;margin-top:1.1rem;font-size:.78rem;color:var(--c-tertiary)}.toc{background:var(--bg-surface);border:1px solid var(--b-rule);border-radius:4px;padding:1.2rem 1.4rem;margin-bottom:2.8rem;box-shadow:var(--sh-sm)}.toc-label{font-weight:700;font-size:.72rem;letter-spacing:.1em;text-transform:uppercase;color:var(--c-tertiary);margin-bottom:.55rem}.toc ol{list-style:none;counter-reset:tc;padding:0}.toc li{counter-increment:tc;margin-bottom:.25rem}.toc li::before{content:counter(tc) \".\";font-weight:600;font-family:'IBM Plex Mono',monospace;font-size:.78rem;margin-right:.45em;color:var(--c-tertiary)}.toc a{font-size:.86rem;color:var(--c-secondary);text-decoration:none}.toc a:hover{color:var(--c-link);text-decoration:underline}.body h2{font-family:'Instrument Sans',sans-serif;font-weight:700;font-size:1.32rem;color:var(--c-body);margin:2.8rem 0 .9rem;padding-bottom:.35rem;border-bottom:1px solid var(--b-light)}.body h3{font-weight:600;font-size:1.05rem;color:var(--c-body);margin:1.7rem 0 .55rem}.body p{margin-bottom:1.15rem;color:var(--c-secondary)}.body .cn{font-size:.84rem;color:var(--c-cn);margin-top:-.55rem;margin-bottom:1.15rem;padding-left:1rem;border-left:2px solid var(--b-light);font-style:italic}.body a{color:var(--c-link);text-decoration:underline;text-underline-offset:2px}.body a:hover{color:var(--c-link-hover)}.body strong{font-weight:600;color:var(--c-body)}.p{font-family:'IBM Plex Mono','Consolas',monospace;font-size:.86em;background:var(--bg-code);padding:.12em .4em;border-radius:3px;color:var(--c-body);white-space:nowrap}.eq{display:block;text-align:center;font-family:'IBM Plex Mono',monospace;font-size:.95rem;padding:1rem;margin:1.2rem 0;background:var(--bg-recessed);border-radius:4px;color:var(--c-body);line-height:1.6}.tw{width:100%;overflow-x:auto;margin:1.4rem 0 2rem;border:1px solid var(--b-table);border-radius:4px;box-shadow:var(--sh-table)}.tw table{width:100%;border-collapse:collapse;font-size:.86rem;line-height:1.5}.tw caption{text-align:left;font-weight:600;font-size:.78rem;letter-spacing:.04em;text-transform:uppercase;color:var(--c-tertiary);padding:.75rem 1rem .35rem;background:var(--bg-surface);border-bottom:1px solid var(--b-light)}.tw thead th{background:var(--bg-th);color:var(--c-inverse);font-weight:600;font-size:.76rem;letter-spacing:.03em;text-transform:uppercase;padding:.65rem 1rem;text-align:left;white-space:nowrap;border-bottom:2px solid var(--b-accent)}.tw tbody td{padding:.55rem 1rem;border-bottom:1px solid var(--b-light);color:var(--c-secondary);vertical-align:top}.tw tbody tr:nth-child(even){background:var(--bg-tr-alt)}.tw tbody tr:hover{background:var(--bg-callout-amber)}.tw tbody td:first-child{font-weight:500;color:var(--c-body);white-space:nowrap}.tw .g{background:var(--hl-green)}.tw .r{background:var(--hl-red)}.note{padding:1rem 1.2rem;margin:1.5rem 0;border-radius:0 4px 4px 0;font-size:.9rem;border-left:3px solid var(--b-accent)}.note.blue{background:var(--bg-callout-blue)}.note.amber{background:var(--bg-callout-amber)}.note.green{background:var(--bg-callout-green)}.note .nt{font-weight:700;font-size:.78rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-body);margin-bottom:.3rem}.note p{margin-bottom:.35rem}.refs{margin-top:2.8rem;padding-top:1.5rem;border-top:2px solid var(--b-rule)}.refs h2{font-size:1.08rem;margin-bottom:.9rem}.rl{list-style:none;counter-reset:rf;padding:0}.rl li{counter-increment:rf;font-size:.8rem;color:var(--c-tertiary);margin-bottom:.55rem;padding-left:2.2rem;position:relative;line-height:1.5}.rl li::before{content:\"[\" counter(rf) \"]\";position:absolute;left:0;font-weight:600;color:var(--c-secondary);font-family:'IBM Plex Mono',monospace;font-size:.75rem}.rl a{color:var(--c-link);word-break:break-all}.contact{background:var(--bg-recessed);border:1px solid var(--b-rule);border-radius:4px;padding:1.5rem;margin-top:2.5rem}.contact h3{font-size:.98rem;margin-bottom:.7rem;color:var(--c-body)}.cg{display:grid;grid-template-columns:repeat(auto-fit,minmax(210px,1fr));gap:.75rem}.ci{font-size:.83rem;color:var(--c-secondary);line-height:1.45}.ci .lb{font-weight:600;font-size:.7rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-tertiary);display:block;margin-bottom:.1rem}.ci a{color:var(--c-link);text-decoration:none}.ci a:hover{text-decoration:underline}.ft{margin-top:2rem;padding-top:1.5rem;border-top:1px solid var(--b-light);font-size:.75rem;color:var(--c-tertiary);text-align:center;line-height:1.55}@media(max-width:600px){.page-wrap{padding:1.2rem 1rem 3rem}.hdr h1{font-size:1.35rem}.tw{font-size:.8rem}.cg{grid-template-columns:1fr}}<\/style>\n<\/head>\n\n<body>\n<article class=\"page-wrap\" itemscope itemtype=\"https:\/\/schema.org\/TechArticle\">\n\n  <header class=\"hdr\">\n    <span class=\"badge\">Feichun Special Cable \u2014 Technical Blog<\/span>\n    <h1 itemprop=\"headline\">AS\/NZS 1802 vs AS\/NZS 1972: Which Australian Standard Applies to Your Underground Mining Equipment?<\/h1>\n    <p class=\"sub\">Complete Technical Guide: Understanding Mobile vs Fixed Mining Cable Standards. Equipment Mobility Determines Your Standard. Earth Continuity Monitoring Strategy. Technical Specification Comparison. Selection Guide for Coal Mine Engineers.<\/p>\n    <p class=\"sub-cn\">\u5b8c\u6574\u6280\u672f\u6307\u5357\uff1a\u7406\u89e3\u79fb\u52a8\u578b\u4e0e\u56fa\u5b9a\u578b\u91c7\u77ff\u7535\u7f06\u6807\u51c6\u3002\u8bbe\u5907\u79fb\u52a8\u6027\u51b3\u5b9a\u4e86\u9002\u7528\u6807\u51c6\u3002\u63a5\u5730\u8fde\u7eed\u6027\u76d1\u6d4b\u7b56\u7565\u3002\u6280\u672f\u89c4\u683c\u5bf9\u6bd4\u3002\u7164\u77ff\u5de5\u7a0b\u5e08\u9009\u578b\u6307\u5357\u3002<\/p>\n    <div class=\"meta\">\n      <span itemprop=\"author\" itemscope itemtype=\"https:\/\/schema.org\/Organization\"><span itemprop=\"name\">Anhui Feichun Special Cable Co., Ltd.<\/span><\/span>\n      <span>|<\/span>\n      <time itemprop=\"datePublished\" datetime=\"2026-03-06\">Mar 06, 2026<\/time>\n      <span>|<\/span>\n      <span>Reading time: ~28 min<\/span>\n    <\/div>\n  <\/header>\n\n  <nav class=\"toc\" aria-label=\"Table of Contents\">\n    <div class=\"toc-label\">Contents<\/div>\n    <ol>\n      <li><a href=\"#s1\">The Golden Rule: Equipment Mobility Determines Your Standard<\/a><\/li>\n      <li><a href=\"#s2\">AS\/NZS 1802: Trailing &#038; Mobile Cable Design Philosophy<\/a><\/li>\n      <li><a href=\"#s3\">AS\/NZS 1972: Fixed &#038; Semi-Fixed Cable Design Philosophy<\/a><\/li>\n      <li><a href=\"#s4\">Earth Continuity Monitoring: Divergent Electrical Strategies<\/a><\/li>\n      <li><a href=\"#s5\">Physical Structure Comparison: Flexibility vs Armour Protection<\/a><\/li>\n      <li><a href=\"#s6\">Technical Specifications: 3.3kV 3\u00d795mm\u00b2 Benchmark Comparison<\/a><\/li>\n      <li><a href=\"#s7\">Bending Radius and Installation Constraints<\/a><\/li>\n      <li><a href=\"#s8\">Semi-Fixed Equipment: The Grey Zone<\/a><\/li>\n      <li><a href=\"#s9\">Common Selection Mistakes and Compliance Failures<\/a><\/li>\n      <li><a href=\"#s10\">Type 241 vs Type 3: Cable Nomenclature Explained<\/a><\/li>\n      <li><a href=\"#s11\">Selection Decision Tree: How to Choose Your Standard<\/a><\/li>\n      <li><a href=\"#s12\">Conclusion: Standard Compliance in Underground Coal Mining<\/a><\/li>\n    <\/ol>\n  <\/nav>\n\n  <div class=\"body\" itemprop=\"articleBody\">\n\n    <h2 id=\"s1\">1. The Golden Rule: Equipment Mobility Determines Your Standard<\/h2>\n\n    <p>In underground coal mining across Australia and New Zealand, selecting between AS\/NZS 1802 and AS\/NZS 1972 is not a matter of personal preference or cost optimization\u2014it is a matter of electrical safety compliance and regulatory requirement. The decision tree, however, is surprisingly straightforward once you understand the single fundamental principle that separates these two standards: <strong>whether your equipment moves while energized<\/strong>.<\/p>\n\n    <p class=\"cn\">\u5728\u6fb3\u5927\u5229\u4e9a\u548c\u65b0\u897f\u5170\u7684\u5730\u4e0b\u7164\u77ff\u7535\u6c14\u8bbe\u8ba1\u4e2d\uff0c\u5728AS\/NZS 1802\u548cAS\/NZS 1972\u4e4b\u95f4\u9009\u62e9\u4e0d\u662f\u4e2a\u4eba\u504f\u597d\u6216\u6210\u672c\u4f18\u5316\u7684\u95ee\u9898\u2014\u2014\u8fd9\u662f\u7535\u6c14\u5b89\u5168\u5408\u89c4\u6027\u548c\u76d1\u7ba1\u8981\u6c42\u7684\u95ee\u9898\u3002\u7136\u800c\uff0c\u4e00\u65e6\u60a8\u7406\u89e3\u5206\u79bb\u8fd9\u4e24\u4e2a\u6807\u51c6\u7684\u5355\u4e00\u57fa\u672c\u539f\u5219\uff0c\u51b3\u7b56\u6811\u5c31\u4f1a\u53d8\u5f97\u51fa\u5947\u5730\u76f4\u63a5\uff1a\u60a8\u7684\u8bbe\u5907\u5728\u901a\u7535\u65f6\u662f\u5426\u79fb\u52a8\u3002<\/p>\n\n    <p><strong>Rule 1 \u2013 AS\/NZS 1802 (Mobile &#038; Dynamic):<\/strong> Use this standard if your equipment requires movement while energized. Continuous miners moving along the coal face, shuttle cars being hauled electrically, reeling drums paying out cable to mobile equipment\u2014these all demand trailing cable designed to flex, bend, and withstand repeated mechanical stress. The cable must survive the physical act of being dragged, coiled, and deployed thousands of times.<\/p>\n\n    <p><strong>Rule 2 \u2013 AS\/NZS 1972 (Fixed &#038; Semi-Fixed):<\/strong> Use this standard if your equipment remains in a fixed location once energized. Underground substation transformers, main water pumps, long-distance fixed conveyor belts, and shaft-mounted switchgear all receive permanent installations where the cable never moves under load. The design priority shifts from mechanical flexibility to structural robustness and armour protection.<\/p>\n\n    <p><strong>The Safety Implication:<\/strong> Using AS\/NZS 1972 (rigid, heavily armoured) on trailing equipment creates excessive stiffness, causing the cable to kink, fold, and fail prematurely. Conversely, using AS\/NZS 1802 (flexible, lighter construction) on fixed installations leaves the cable vulnerable to mechanical damage, crushing, and puncture by surrounding equipment and rock fall.<\/p>\n\n    <h2 id=\"s2\">2. AS\/NZS 1802: Trailing &#038; Mobile Cable Design Philosophy<\/h2>\n\n    <p>The AS\/NZS 1802 standard is explicitly designed for cables that must be laid out, coiled, reeled, and dragged repeatedly without breaking. This standard encompasses what British and European practice calls &#8220;trailing&#8221; cables\u2014power and control cables routed from fixed power sources to mobile machines that must receive power while moving.<\/p>\n\n    <p><strong>Core Design Features of AS\/NZS 1802:<\/strong> The electrical conductors at the center are designed with Class 5 flexibility (very fine strands, typically 40\u201360 individual copper filaments per conductor) to permit repeated bending to small radii. A semi-conducting rubber layer surrounds the conductors, providing electrostatic screening and permitting gradual stress distribution within the insulation. The insulation itself is typically EPR (ethylene propylene rubber), chosen for its ability to recover elastically after flexing, rather than XLPE, which would crack under repeated bending. A pilot core runs through the center, enabling earth continuity monitoring via periodic low-voltage pulses that detect cable damage before it becomes catastrophic.<\/p>\n\n    <p><strong>Cable Structure Schematic (AS\/NZS 1802):<\/strong> Starting from the center and moving outward: Class 5 copper conductors (very fine, highly flexible) \u2192 Semi-conducting screen (5\u201310 mm) \u2192 EPR insulation (2.5\u20134 mm thick depending on voltage) \u2192 Semi-conducting outer screen \u2192 Pilot core (typically 0.5\u20131.5 mm copper, uninsulated or with thin insulation) \u2192 Elastomeric inner sheath (3\u20135 mm, typically PCP\/CPE for flame retardance) \u2192 Optional braided reinforcement \u2192 Tough outer PCP\/CPE sheath (5\u20138 mm, often high-visibility red or yellow).<\/p>\n\n    <p><strong>Typical Equipment Using AS\/NZS 1802:<\/strong> Continuous mining machines (longwall shearers, power loaders), shuttle cars, roof bolting machines, heading machines, and any surface or underground equipment that must be repositioned while energized.<\/p>\n\n    <h2 id=\"s3\">3. AS\/NZS 1972: Fixed &#038; Semi-Fixed Cable Design Philosophy<\/h2>\n\n    <p>The AS\/NZS 1972 standard addresses cables installed in relatively permanent locations where bending is minimal and mechanical protection from external hazards (rock fall, equipment impacts) is paramount. Rather than flexibility, the design emphasizes structural integrity and armor protection.<\/p>\n\n    <p><strong>Core Design Features of AS\/NZS 1972:<\/strong> The electrical conductors are typically Class 2 (fewer, thicker strands\u2014perhaps 7\u201315 filaments per conductor), optimizing for current-carrying capacity and mechanical strength rather than bending flexibility. The insulation is usually XLPE (cross-linked polyethylene), chosen for superior voltage stress tolerance and resistance to sustained moisture in shaft and drift applications. The outer sheath and armor layers are dramatically heavier than AS\/NZS 1802. Where AS\/NZS 1802 might employ a simple elastomeric outer jacket, AS\/NZS 1972 cables feature either SWA (steel wire armour\u2014rigid, non-flexible) or PWA (pliable wire armour\u2014flexible but still much stiffer than AS\/NZS 1802 designs). The armor serves two functions: mechanical protection from impact and puncture, and a backup earth return path in case the primary earth conductor is damaged.<\/p>\n\n    <p><strong>Cable Structure Schematic (AS\/NZS 1972):<\/strong> Class 2 copper conductors (fewer, thicker strands) \u2192 Semi-conducting screen (3\u20138 mm) \u2192 XLPE insulation (3\u20136 mm thick, voltage-dependent) \u2192 Semi-conducting outer screen \u2192 Copper braided or taped shield (optional) \u2192 Inner copper or aluminum tape (provides additional earth continuity) \u2192 Steel or pliable wire armour (SWA: 2\u20134 mm diameter wires, or PWA: 1\u20132 mm stranded wires in helical pattern) \u2192 Outer PVC\/PCP sheath (5\u201310 mm).<\/p>\n\n    <p><strong>Typical Equipment Using AS\/NZS 1972:<\/strong> Fixed transformers, permanent pump installations, fixed conveyor belt drives, shaft switchgear, boreholes and fixed drilling systems, long-distance power distribution throughout the mine, and equipment that receives power only at one fixed location.<\/p>\n\n    <h2 id=\"s4\">4. Earth Continuity Monitoring: Divergent Electrical Strategies<\/h2>\n\n    <p>One of the most critical but poorly understood differences between these standards lies in how they detect faults before they become catastrophic. Both standards address electrical safety, but through fundamentally different mechanisms reflecting their operational context.<\/p>\n\n    <p><strong>AS\/NZS 1802 \u2013 Pilot Core Continuous Monitoring:<\/strong> The pilot core is a thin copper conductor (0.5\u20131.5 mm) running through the center of the cable alongside the main power conductors. During normal operation, a monitoring device at the trailing cable&#8217;s entry point applies a low-voltage test signal (typically 100\u2013200 V AC at micro-ampere levels) between one of the main phase conductors and the pilot core. This signal continuously monitors electrical continuity. If the cable is damaged\u2014perhaps crushed by rolling equipment or torn by sharp rock\u2014the damage typically breaches both the insulation and the pilot core simultaneously. The breach creates a short circuit or dramatic change in monitored resistance, triggering an immediate alarm and cutting power via the trailing cable socket or reel system before personnel are exposed. This design reflects the reality of mobile equipment: damage happens suddenly and catastrophically, so immediate detection and power removal are essential.<\/p>\n\n    <p><strong>AS\/NZS 1972 \u2013 Armor and Earth Bond Backup Strategy:<\/strong> Fixed installations rely on more traditional earth continuity mechanisms. A dedicated earth conductor (independent of the main power conductors) runs the entire cable length, sized according to AS\/NZS 3008 calculations. Additionally, the armor layers (SWA or PWA) and any braided shields provide redundant earth return paths. In the event of a single-point insulation failure, the fault current flows through the main earth conductor to ground, creating a large current spike that triggers conventional overcurrent protection (fuses, circuit breakers, residual current devices). The time delay\u2014typically milliseconds to seconds depending on protection coordination\u2014is acceptable because the cable is not moving and exposure is limited to personnel in the immediate vicinity who are presumably trained and equipped. The armor and multiple earth bonds ensure that no single point of damage can both isolate the earth path and leave the cable energized.<\/p>\n\n    <h2 id=\"s5\">5. Physical Structure Comparison: Flexibility vs Armour Protection<\/h2>\n\n    <p>To understand the magnitude of difference between these standards, consider how they respond to the same mechanical stress. A 300 mm radius bend\u2014tight enough to cause problems\u2014affects the two cable types very differently.<\/p>\n\n    <p><strong>AS\/NZS 1802 Under 300 mm Bend:<\/strong> The cable flexes smoothly. The Class 5 conductors bend around the radius with individual copper filaments sliding past each other slightly. The EPR insulation elastically deforms but recovers when the bending stress is removed. The pilot core flexes without fracturing. When released, the cable returns to its original shape. This can be repeated thousands of times during the equipment&#8217;s operational life.<\/p>\n\n    <p><strong>AS\/NZS 1972 Under 300 mm Bend:<\/strong> The cable exhibits significant mechanical stress. The Class 2 conductors, being thicker and fewer in number, do not bend as flexibly\u2014individual wires experience internal cracking. The XLPE insulation, brittle compared to EPR, develops micro-fractures. Most critically, the SWA or PWA armor resists the bend, creating high internal bending stresses. Repeated bending would cause armor wire breaks, potentially exposing the insulation. The cable is not designed to survive this. Permanent installation assumes a large bending radius (12\u201315 times outer diameter) achieved once during installation and never repeated.<\/p>\n\n    <h2 id=\"s6\">6. Technical Specifications: 3.3kV 3\u00d795mm\u00b2 Benchmark Comparison<\/h2>\n\n    <p>To ground this discussion in concrete engineering data, the following table presents side-by-side specifications for cables of identical electrical rating (3.3 kV, 3 \u00d7 95 mm\u00b2 copper per phase) but compliant with different standards. This represents the most common voltage and conductor size in Australian underground coal mining.<\/p>\n\n    <div class=\"tw\">\n      <caption>Table 1 \u2014 AS\/NZS 1802 vs AS\/NZS 1972 Technical Specifications (3.3kV, 3\u00d795mm\u00b2, Air Installation, 40\u00b0C)<\/caption>\n      <table>\n        <thead>\n          <tr>\n            <th>Specification<\/th>\n            <th>AS\/NZS 1802 (Trailing)<\/th>\n            <th>AS\/NZS 1972 (Fixed)<\/th>\n            <th>Unit<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>Outer Diameter (OD)<\/td>\n            <td class=\"g\">~28\u201332<\/td>\n            <td class=\"r\">~42\u201348<\/td>\n            <td>mm<\/td>\n          <\/tr>\n          <tr>\n            <td>Cable Weight<\/td>\n            <td class=\"g\">~840\u2013920<\/td>\n            <td class=\"r\">~2,100\u20132,400<\/td>\n            <td>kg\/km<\/td>\n          <\/tr>\n          <tr>\n            <td>Weight Per Meter<\/td>\n            <td class=\"g\">~0.84\u20130.92<\/td>\n            <td class=\"r\">~2.1\u20132.4<\/td>\n            <td>kg\/m<\/td>\n          <\/tr>\n          <tr>\n            <td>Ampacity (40\u00b0C, air)<\/td>\n            <td class=\"g\">~225<\/td>\n            <td class=\"g\">~240<\/td>\n            <td>A<\/td>\n          <\/tr>\n          <tr>\n            <td>Conductor Stranding<\/td>\n            <td class=\"g\">Class 5 (40\u201360 filaments)<\/td>\n            <td class=\"r\">Class 2 (7\u201315 filaments)<\/td>\n            <td>\u2014<\/td>\n          <\/tr>\n          <tr>\n            <td>Insulation Material<\/td>\n            <td class=\"g\">EPR (elastic recovery)<\/td>\n            <td class=\"r\">XLPE (high strength)<\/td>\n            <td>\u2014<\/td>\n          <\/tr>\n          <tr>\n            <td>Insulation Thickness<\/td>\n            <td class=\"g\">~2.5\u20133.0<\/td>\n            <td class=\"r\">~3.5\u20134.5<\/td>\n            <td>mm<\/td>\n          <\/tr>\n          <tr>\n            <td>Outer Sheath<\/td>\n            <td class=\"g\">PCP\/CPE elastomer (5\u20137 mm)<\/td>\n            <td class=\"r\">PVC\/PCP (6\u20138 mm) + SWA\/PWA armor<\/td>\n            <td>\u2014<\/td>\n          <\/tr>\n          <tr>\n            <td>Armor Type<\/td>\n            <td class=\"g\">None (or optional mesh)<\/td>\n            <td class=\"r\">SWA (2\u20134 mm) or PWA (1\u20132 mm stranded)<\/td>\n            <td>\u2014<\/td>\n          <\/tr>\n          <tr>\n            <td>Dynamic Bending Radius<\/td>\n            <td class=\"g\">6\u20138 \u00d7 OD<\/td>\n            <td class=\"r\">Not recommended for dynamic use<\/td>\n            <td>\u2014<\/td>\n          <\/tr>\n          <tr>\n            <td>Static Installation Bending Radius<\/td>\n            <td class=\"g\">12 \u00d7 OD (typical)<\/td>\n            <td class=\"r\">12\u201315 \u00d7 OD<\/td>\n            <td>\u2014<\/td>\n          <\/tr>\n          <tr>\n            <td>Earth Continuity Method<\/td>\n            <td class=\"g\">Pilot core + continuous monitoring<\/td>\n            <td class=\"r\">Dedicated earth conductor + armor bonds<\/td>\n            <td>\u2014<\/td>\n          <\/tr>\n          <tr>\n            <td>Pilot Core (AS\/NZS 1802)<\/td>\n            <td class=\"g\">0.75\u20131.5 mm copper uninsulated<\/td>\n            <td class=\"r\">N\/A<\/td>\n            <td>\u2014<\/td>\n          <\/tr>\n          <tr>\n            <td>Typical Cost (per meter)<\/td>\n            <td class=\"g\">~$18\u201324<\/td>\n            <td class=\"r\">~$35\u201348<\/td>\n            <td>AUD<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <p>Notice the substantial differences: the AS\/NZS 1972 cable is roughly 2.5 times heavier, has a 50% larger outer diameter, and costs nearly double. These differences are not design oversights\u2014they directly reflect the operational environment and safety requirements of each application.<\/p>\n\n    <h2 id=\"s7\">7. Bending Radius and Installation Constraints<\/h2>\n\n    <p><strong>AS\/NZS 1802 Dynamic Bending (Trailing Equipment):<\/strong> When a cable is actively being reeled, coiled, or dragged, it must bend to tight radii repeatedly without failure. Acceptable dynamic bending radius for AS\/NZS 1802 cables is typically 6 to 8 times the cable&#8217;s outer diameter. For a 30 mm OD cable, this means a 180\u2013240 mm bend radius is permissible. This tight bending is achieved through the Class 5 stranding and EPR insulation design. Equipment specifications from manufacturers like Sandvik (continuous miners) and Joy Global (longwall systems) explicitly reference dynamic bending radii of this magnitude because the cable must bend around the machinery&#8217;s reeling drums.<\/p>\n\n    <p><strong>AS\/NZS 1972 Static Installation Bending:<\/strong> Once installed, AS\/NZS 1972 cables are bent to their final radius and rarely (if ever) bent again. The bending radius must be at least 12 to 15 times the outer diameter, typically achieved once during installation and then held in place with cleats and support brackets. For a 45 mm OD cable, this mandates a minimum bend radius of 540\u2013675 mm. Forcing an AS\/NZS 1972 cable into a 300 mm bend radius during installation would be a design violation and would risk armor integrity and internal conductor cracking.<\/p>\n\n    <p><strong>Installation Implication:<\/strong> If you receive an AS\/NZS 1972 cable and need to route it through a confined space requiring tight bending, you must redesign the routing or risk cable failure during installation. Conversely, if you install an AS\/NZS 1802 cable in a fixed location with protective armor, you are underutilizing the cable&#8217;s design intent\u2014it is oversized for that application and wastes cost and installation labor.<\/p>\n\n    <h2 id=\"s8\">8. Semi-Fixed Equipment: The Grey Zone<\/h2>\n\n    <p>Not all underground equipment falls neatly into the &#8220;mobile&#8221; or &#8220;fixed&#8221; category. Some equipment is relocated periodically but remains energized during each stationary period. Examples include conveyor drive stations that are repositioned every 2\u20134 weeks as the coal face advances, or portable pump units deployed to manage water in a working section and later relocated when the section is depleted.<\/p>\n\n    <p><strong>The Engineering Recommendation for Semi-Fixed Equipment:<\/strong> When equipment must be moved occasionally but remains energized during each operational period, use AS\/NZS 1972 cable with PWA (pliable wire armour) rather than rigid SWA (steel wire armour). PWA uses thinner, stranded wires in a helical pattern, making the armor more flexible than SWA while retaining the protective and mechanical properties of the AS\/NZS 1972 structure. PWA cables can tolerate limited repositioning\u2014typically 2\u20134 moves over the cable&#8217;s operational life\u2014without damage, whereas SWA cables risk armor wire breaks if bent excessively more than once.<\/p>\n\n    <p><strong>Cost-Benefit Analysis:<\/strong> A PWA cable costs roughly 15\u201325% more than equivalent SWA but significantly less than a full AS\/NZS 1802 cable (which may cost double or triple the SWA equivalent). For semi-fixed applications, PWA represents the optimal balance of protection and occasional mobility.<\/p>\n\n    <h2 id=\"s9\">9. Common Selection Mistakes and Compliance Failures<\/h2>\n\n    <div class=\"note amber\">\n      <div class=\"nt\">Mistake 1: Installing AS\/NZS 1972 on Trailing Equipment<\/div>\n      <p>An operator receives a continuous miner with an AS\/NZS 1972 cable already installed (perhaps the supplier had stock and minimized cost). During deployment, the cable is forced onto the reeling drum, kinking sharply. The armor wires crack. Within weeks of operation, an internal short develops, causing phase-to-phase arcing. The equipment shuts down unexpectedly, halting production. Root cause investigation reveals improper cable selection. Lesson: Always verify equipment specifications against cable documentation before deployment.<\/p>\n    <\/div>\n\n    <div class=\"note amber\">\n      <div class=\"nt\">Mistake 2: Installing AS\/NZS 1802 on Fixed Infrastructure<\/div>\n      <p>A substation expansion uses AS\/NZS 1802 cable (misidentified as &#8220;universal&#8221; cable) to connect a new transformer. The lighter cable requires more supports and cleats to prevent sag, increasing labor costs. More critically, the absence of armor leaves the cable vulnerable. When a concrete support structure is repositioned during later expansion work, it crushes the unarmoured cable, causing a phase-to-earth short circuit. The substation section fails, disrupting power to the mine. Lesson: Fixed installations must use armoured AS\/NZS 1972 cable regardless of initial cost.<\/p>\n    <\/div>\n\n    <div class=\"note amber\">\n      <div class=\"nt\">Mistake 3: Ignoring Pilot Core Integrity on AS\/NZS 1802<\/div>\n      <p>A longwall operation continues using a trailing cable despite pilot core monitoring repeatedly reporting high-resistance readings. Operators assume the monitoring is oversensitive. Weeks later, the cable suffers damage at a cleat location where the pilot core fractured. The monitoring system had detected this damage but was not taken seriously. The cable is now partially insulated (via the pilot core fracture), creating a partial short circuit that overheats the insulation and causes personnel exposure to arc flash. Lesson: Pilot core monitoring alerts are not nuisances\u2014they are early warnings of developing faults. Respond immediately with cable inspection or replacement.<\/p>\n    <\/div>\n\n    <h2 id=\"s10\">10. Type 241 vs Type 3: Cable Nomenclature Explained<\/h2>\n\n    <p>Throughout Australian mining practice, engineers sometimes reference &#8220;Type 241&#8221; or &#8220;Type 3&#8221; cables. These nomenclatures derive from earlier cable standards and can cause confusion when compared against the modern AS\/NZS designations.<\/p>\n\n    <p><strong>Type 241 (Older Nomenclature):<\/strong> This designation historically referred to flexible trailing cables, roughly equivalent to modern AS\/NZS 1802. Cables labeled &#8220;Type 241&#8221; typically featured a pilot core, EPR insulation, and Class 5 conductors. Modern specifications now prefer the AS\/NZS 1802 designation, but legacy equipment and documentation may still reference Type 241.<\/p>\n\n    <p><strong>Type 3 (Older Nomenclature):<\/strong> This referred to fixed, armoured cables broadly similar to AS\/NZS 1972. Type 3 cables featured Class 2 conductors, XLPE insulation, and typically SWA armour. The modern equivalent is AS\/NZS 1972, though Type 3 nomenclature persists in some regional specifications.<\/p>\n\n    <p><strong>When Specifying Cables:<\/strong> Use the modern AS\/NZS 1802 and AS\/NZS 1972 designations. These are internationally recognized, traceable to official Australian and New Zealand Standards, and acceptable to electrical inspectors and insurance auditors. If a supplier references &#8220;Type 241&#8221; or &#8220;Type 3,&#8221; request clarification and ask for specific compliance documentation against the applicable AS\/NZS standard.<\/p>\n\n    <h2 id=\"s11\">11. Selection Decision Tree: How to Choose Your Standard<\/h2>\n\n    <div class=\"note green\">\n      <div class=\"nt\">Practical Selection Flowchart<\/div>\n      <p><strong>Question 1: Does the equipment move while energized?<\/strong> If YES, proceed to Question 2. If NO, specify AS\/NZS 1972 (fixed installation cable). Use SWA armor for maximum protection, or PWA if occasional repositioning is anticipated.<\/p>\n      <p><strong>Question 2: How often does the equipment move?<\/strong> If continuously (e.g., shuttle car, continuous miner), specify AS\/NZS 1802 with a pilot core and continuous monitoring system. If occasionally (e.g., semi-fixed conveyor, repositioned quarterly), specify AS\/NZS 1972 with PWA (pliable wire) armor. If once during installation and never again, specify AS\/NZS 1972 with SWA (steel wire) armor.<\/p>\n      <p><strong>Question 3: What is the installation environment?<\/strong> If the cable is exposed to rock fall, crushing hazards, or mechanical impacts, emphasize armor protection. If the cable is routed through protected ducting or channels, lighter armor (PWA) is acceptable. If the cable is buried or placed in protective conduit, AS\/NZS 1802 without armor may suffice for trailing equipment (though AS\/NZS 1972 is always safer for fixed installations).<\/p>\n      <p><strong>Question 4: Does pilot core monitoring exist?<\/strong> For AS\/NZS 1802 cables, verify that the equipment&#8217;s power distribution system includes a pilot core monitoring panel. If it does not, retrofitting is expensive. If you do not have monitoring capability, you cannot safely rely on AS\/NZS 1802 alone\u2014you must use AS\/NZS 1972 with earthed armor as backup protection.<\/p>\n    <\/div>\n\n    <h2 id=\"s12\">12. Conclusion: Standard Compliance in Underground Coal Mining<\/h2>\n\n    <p><strong>Summary \u2013 Safe Cable Selection Requirements:<\/strong> The choice between AS\/NZS 1802 and AS\/NZS 1972 is fundamentally a choice between two electrical safety philosophies. AS\/NZS 1802 prioritizes continuous monitoring and rapid fault detection (suitable for mobile equipment where sudden damage is a real risk). AS\/NZS 1972 prioritizes robust mechanical protection and redundant earthing (suitable for fixed installations where exposure is limited and damage is rare). Selecting the wrong standard does not simply increase costs or cause inconvenience\u2014it creates electrical hazards that endanger personnel and disrupt mine operations.<\/p>\n\n    <p><strong>Engineering Best Practice:<\/strong> Coordinate cable selection at the equipment procurement stage, not after delivery. Verify that the equipment supplier&#8217;s electrical specification explicitly references the applicable AS\/NZS standard. Request cable documentation (test certificates, manufacturing records, standard compliance statements) before installation. For trailing equipment, confirm that the site&#8217;s power distribution system includes pilot core monitoring compatible with the cable&#8217;s design. For fixed installations, verify that armor bonding and earthing calculations comply with AS\/NZS 3008. Conduct pre-installation cable inspection to confirm that delivered cables match specifications\u2014no substitutions.<\/p>\n\n    <p><strong>Final Note:<\/strong> Feichun Special Cable manufactures both AS\/NZS 1802 (trailing cable with pilot core and elastomeric design) and AS\/NZS 1972 (fixed cable with SWA or PWA armor) in all common voltage and conductor sizes for Australian and New Zealand coal mining operations. Our technical team can audit your existing cable specifications, recommend upgrades if standards have drifted, and supply certified, compliant cables with full documentation. Contact us for site surveys, cable calculations, and installation supervision to ensure electrical safety compliance across your underground operations.<\/p>\n\n  <\/div>\n\n  <section class=\"refs\">\n    <h2>References &#038; Sources<\/h2>\n    <ol class=\"rl\">\n      <li>AS\/NZS 1802:2012, &#8220;Flexible cables with copper conductors\u2014General purpose cables for underground mines,&#8221; Standards New Zealand and Standards Australia.<\/li>\n      <li>AS\/NZS 1972:2012, &#8220;Fixed electric cables\u2014General purpose cables for underground mining,&#8221; Standards New Zealand and Standards Australia.<\/li>\n      <li>AS\/NZS 3008.1.1:2017, &#8220;Electrical installations\u2014Selection of cables,&#8221; Standards New Zealand and Standards Australia.<\/li>\n      <li>WorkSafe Victoria, &#8220;Electrical Safety in Mining,&#8221; Mining Industry Code of Practice, 2023.<\/li>\n      <li>Feichun Special Cable Technical Team, &#8220;AS\/NZS 1802 vs AS\/NZS 1972 Selection and Compliance Guide,&#8221; Technical Document, 2026.<\/li>\n    <\/ol>\n  <\/section>\n\n  <div class=\"contact\">\n    <h3>Contact Anhui Feichun Special Cable Co., Ltd.<\/h3>\n    <div class=\"cg\">\n      <div class=\"ci\">\n        <span class=\"lb\">AS\/NZS Mining Cable Standards &#038; Selection<\/span>\n        <a href=\"mailto:tech@feichuncables.com\" rel=\"nofollow\">tech@feichuncables.com<\/a>\n      <\/div>\n      <div class=\"ci\">\n        <span class=\"lb\">Trailing &#038; Mobile Equipment Cables<\/span>\n        <a href=\"mailto:mining@feichuncables.com\" rel=\"nofollow\">mining@feichuncables.com<\/a>\n      <\/div>\n      <div class=\"ci\">\n        <span class=\"lb\">Fixed &#038; Armoured Cable Supply<\/span>\n        <a href=\"mailto:sales@feichuncables.com\" rel=\"nofollow\">sales@feichuncables.com<\/a>\n      <\/div>\n      <div class=\"ci\">\n        <span class=\"lb\">WhatsApp \/ WeChat<\/span>\n        <a href=\"https:\/\/wa.me\/8613855123218\" rel=\"nofollow noopener\" target=\"_blank\">+86 138-5512-3218<\/a>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <footer class=\"ft\">\n    <p>&copy; 2026 Anhui Feichun Special Cable Co., Ltd. \u2014 All rights reserved.<\/p>\n    <p>Building A, Private Science &#038; Technology Park, Hefei Economic and Technological Development Zone, Anhui Province, China.<\/p>\n    <p><strong>SEO Keywords:<\/strong> AS\/NZS 1802, AS\/NZS 1972, underground mining cable standards, trailing cable, feeder cable, mobile mining equipment, fixed mining cable, Type 241, Type 3, SWA armour, pliable wire armour, pilot core cable, earth continuity monitoring, 3.3kV cable, 6.6kV cable, 11kV cable, continuous miner cable, shuttle car cable, longwall shearer cable, conveyor drive cable, mining substation cable, Class 5 conductor, Class 2 conductor, EPR insulation, XLPE insulation, mining cable selection, Australian mining standards, New Zealand mining standards, coal mine electrical compliance, cable bending radius, cable ampacity, mining equipment power supply, semi-fixed mining equipment, dynamic cable, static cable installation, cable armor protection, cable monitoring system, mining cable technical specifications, underground coal mine, electrical safety mining, mining infrastructure, heavy duty cable, flame retardant cable.<\/p>\n  <\/footer>\n\n<\/article>\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"In underground coal mining across Australia and New Zealand, selecting between AS\/NZS 1802 and AS\/NZS 1972 is not a matter of personal preference or cost optimization\u2014it is a matter of electrical safety compliance and regulatory requirement. The decision tree, however, is surprisingly straightforward once you understand the single fundamental principle that separates these two standards: whether your equipment moves while energized.\n\u5728\u6fb3\u5927\u5229\u4e9a\u548c\u65b0\u897f\u5170\u7684\u5730\u4e0b\u7164\u77ff\u7535\u6c14\u8bbe\u8ba1\u4e2d\uff0c\u5728AS\/NZS 1802\u548cAS\/NZS 1972\u4e4b\u95f4\u9009\u62e9\u4e0d\u662f\u4e2a\u4eba\u504f\u597d\u6216\u6210\u672c\u4f18\u5316\u7684\u95ee\u9898\u2014\u2014\u8fd9\u662f\u7535\u6c14\u5b89\u5168\u5408\u89c4\u6027\u548c\u76d1\u7ba1\u8981\u6c42\u7684\u95ee\u9898\u3002\u7136\u800c\uff0c\u4e00\u65e6\u60a8\u7406\u89e3\u5206\u79bb\u8fd9\u4e24\u4e2a\u6807\u51c6\u7684\u5355\u4e00\u57fa\u672c\u539f\u5219\uff0c\u51b3\u7b56\u6811\u5c31\u4f1a\u53d8\u5f97\u51fa\u5947\u5730\u76f4\u63a5\uff1a\u60a8\u7684\u8bbe\u5907\u5728\u901a\u7535\u65f6\u662f\u5426\u79fb\u52a8\u3002","protected":false},"author":1,"featured_media":8552,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[222,46145,66],"tags":[46261,1674,46409,3322,35607,36925,46443,46281,45668,46506,46401,46439,36852,46496,46348,46495,46494,6428,43718,4040,6084,46168,36851,1114,6052,46493,46500,46406,46405,4342,46515,46122,46509,46492,1170,46118,4816,36834,46505,3726,46491,778,46490,5272,2954,892,46514,46498,1679,46512,46257,46511,46437,46497,1990,46507,1965,3340,46119,45574,44194,3598,46143,3380,1966,44458,4537,1746,9582,1683,46167,3817,46510,5281,46517,35671,37665,46499,7600,46516,46513,1008,14258,5608,46504,46402,46456,46508,46471,46503,46164,46158,46502,799,8147,46501],"class_list":["post-8551","post","type-post","status-publish","format-standard","has-post-thumbnail","category-as-nzs-1802-reeling-cables-for-underground-mining","category-as-nzs-1972-electric-cables-underground-coal-mines","category-common-problems-encountered-in-cable-applications","tag-11kv-3-core-mining-cable","tag-11kv-mining-cable","tag-11kv-shaft-cable","tag-3-3kv-mining-cable","tag-as-nzs-1802-standard","tag-as-nzs-1802-type-241","tag-as-nzs-1802-vs-as-nzs-1972","tag-as-nzs-1972-specifications","tag-as-nzs-1972-standard","tag-as-nzs-1972-type-3","tag-as-nzs-1972-type-8","tag-as-nzs-1972-type-9","tag-as-nzs-3008","tag-as-nzs-60079-1","tag-as-nzs-mining-compliance","tag-awg-mining-cable-specs","tag-bambach-type-9","tag-cable-selection-mining","tag-cable-suspension-clamp","tag-caledonian-mining-cable","tag-class-5-vs-class-2-conductor","tag-coal-mine-power-distribution","tag-coal-mine-safety","tag-continuous-miner-cable","tag-conveyor-belt-power-cable","tag-deep-level-mining-electrical","tag-double-armored-hv-cable","tag-double-wire-armour-cable","tag-dwa-mining-cable","tag-earth-continuity-monitoring","tag-electrical-compliance-australia","tag-electrical-engineer-mining","tag-electrical-engineering-mining-australia","tag-ex-d-cable-gland","tag-explosion-proof-cable","tag-explosion-proof-cable-design","tag-explosive-atmosphere-cable","tag-extensible-pilot-core","tag-fixed-mining-cable","tag-flame-retardant-mining-cable-2","tag-flameproof-enclosure-cable","tag-flexible-mining-cable","tag-gas-non-transmission-cable-2","tag-heavy-duty-mine-cable","tag-heavy-duty-rubber-cable","tag-high-mechanical-stress-cable","tag-individual-screen-vs-overall-screen","tag-intrinsic-safety-mining","tag-longwall-shearer-cable","tag-mine-electrical-safety-standards","tag-mine-load-centre","tag-mine-power-distribution-system","tag-mine-shaft-winder-cable","tag-mine-winder-electrical","tag-mining-cable-ampacity","tag-mining-cable-awg-to-mm2","tag-mining-cable-bending-radius","tag-mining-cable-comparison","tag-mining-cable-copper-weight","tag-mining-cable-cross-section","tag-mining-cable-outer-diameter","tag-mining-cable-replacement","tag-mining-cable-technical-data","tag-mining-cable-weight","tag-mining-control-cable","tag-mining-electrical-engineering","tag-mining-equipment-power","tag-mining-equipment-power-supply","tag-mining-substation-cable","tag-mobile-mining-equipment-cable","tag-olex-mining-cable","tag-pcp-sheath-mining-cable","tag-pliable-wire-armour","tag-prysmian-mining-cable","tag-pump-station-cable-mining","tag-pvc-sheath-mining-cable","tag-reeling-and-trailing-cables","tag-shaft-hoisting-system","tag-shaft-sinking-cable","tag-short-circuit-protection-mining","tag-shuttle-car-cable-standards","tag-steel-wire-armoured-cable","tag-swa-mining-cable","tag-torsional-stress-cable","tag-trailing-cable-vs-feeder-cable","tag-type-8-mining-cable","tag-type-9-mining-cable","tag-underground-coal-mine-compliance","tag-underground-coal-mine-shaft","tag-underground-mining-cable-selection","tag-underground-mining-infrastructure","tag-underground-substation-feeder","tag-vertical-drop-mining-cable","tag-vertical-installation-cable","tag-vertical-shaft-cable","tag-zone-1-hazardous-area-cable","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/8551","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=8551"}],"version-history":[{"count":1,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/8551\/revisions"}],"predecessor-version":[{"id":8553,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/8551\/revisions\/8553"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/8552"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=8551"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=8551"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=8551"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}