{"id":8468,"date":"2026-03-05T17:30:38","date_gmt":"2026-03-05T09:30:38","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=8468"},"modified":"2026-03-05T17:30:44","modified_gmt":"2026-03-05T09:30:44","slug":"thyssenkrupp-stacker-reclaimers-matching-vde-mechanicals-with-6-6-6-6kv-australian-voltages","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/thyssenkrupp-stacker-reclaimers-matching-vde-mechanicals-with-6-6-6-6kv-australian-voltages\/","title":{"rendered":"ThyssenKrupp Stacker Reclaimers: Matching VDE Mechanicals with 6.6\/6.6kV Australian Voltages"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Complete Technical Guide to Matching VDE Mechanical Standards with 6.6\/6.6kV Australian Voltages for ThyssenKrupp Stacker Reclaimer Cables. High-Speed Reeling Performance Analysis (120\u2013160 m\/min), Anti-Torsion Design Requirements, Tensile Strength Specifications, AS\/NZS 2802 Compliance, Bulk Material Handling and Port Machinery Applications.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e3a\u8482\u68ee\u514b\u864f\u4f2f\u5806\u53d6\u6599\u673a\u7535\u7f06\u5c06VDE\u673a\u68b0\u6807\u51c6\u4e0e6.6\/6.6kV\u6fb3\u6d32\u7535\u538b\u76f8\u5339\u914d\u7684\u5b8c\u6574\u6280\u672f\u6307\u5357\u3002\u9ad8\u901f\u5377\u7b52\u6027\u80fd\u5206\u6790(120-160 m\/min)\u3001\u9632\u626d\u8f6c\u8bbe\u8ba1\u8981\u6c42\u3001\u6297\u62c9\u5f3a\u5ea6\u89c4\u8303\u3001AS\/NZS 2802\u5408\u89c4\u6027\u3001\u6563\u8d27\u642c\u8fd0\u548c\u6e2f\u53e3\u673a\u68b0\u5e94\u7528\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-dominant-color=\"494548\" data-has-transparency=\"false\" style=\"--dominant-color: #494548;\" loading=\"lazy\" decoding=\"async\" width=\"1025\" height=\"628\" sizes=\"auto, (max-width: 1025px) 100vw, 1025px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-957-1025x628.avif\" alt=\"\" class=\"wp-image-8469 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-957-1025x628.avif 1025w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-957-300x184.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-957-768x470.avif 768w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-957-400x245.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-957-800x490.avif 800w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-957-832x510.avif 832w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-957.avif 1094w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n<title>ThyssenKrupp Stacker Reclaimers: Matching VDE Mechanicals with 6.6\/6.6kV Australian Voltages | Feichun Cable<\/title>\n<meta name=\"description\" content=\"Complete technical guide: Matching VDE mechanical standards with 6.6\/6.6kV Australian voltages for ThyssenKrupp stacker reclaimer cables. High-speed reeling performance, anti-torsion design, tensile strength analysis, AS\/NZS 2802 compliance, bulk material handling and port machinery applications.\">\n<meta name=\"keywords\" content=\"ThyssenKrupp stacker reclaimer cable, 6.6kV reeling cable, 6.6\/6.6kV mining cable, medium voltage reeling cable, AS\/NZS 2802 cable, Type 241 trailing cable, Type 275 reeling cable, VDE 0250-813, NTSCGEW\u00d6U 6\/10kV, Australian mining cable, flexible MV cable, bulk material handling cable, port machinery cable, heavy duty reeling cable, stacker reclaimer power supply, drum reeling cable, mining dragline cable, ship unloader cable, bucket wheel excavator cable, high tensile reeling cable, flexible trailing cable, EPR insulated mining cable, PUR sheathed reeling cable, CPE mining cable, 6.6kV flexible cable, ThyssenKrupp spare parts, mining equipment cable replacement, medium voltage flexible copper cable, AS\/NZS mining standards, continuous miner cable, flexible heavy duty power cable, trailing cable ampacity, reeling cable dimensions, outer diameter reeling cable, torsion resistant cable, UV resistant mining cable, abrasion resistant power cable, VDE standard flexible cable, industrial reeling solutions, festoon system cable, mono spiral drum cable, multi layer drum reeling, AS\/NZS 1125 conductors, AS\/NZS 3808 insulation, customized mining cable, open pit mining cable, surface mining trailing cable, high speed reeling cable, flexible mining cable manufacturer, heavy duty port cable\">\n<meta name=\"author\" content=\"Anhui Feichun Special Cable Co., Ltd.\">\n<link rel=\"canonical\" href=\"https:\/\/feichuncables.com\/blog\/thyssenkrupp-stacker-6-6kv\/\">\n<link rel=\"preconnect\" href=\"https:\/\/fonts.googleapis.com\">\n<link rel=\"preconnect\" href=\"https:\/\/fonts.gstatic.com\" crossorigin>\n<link href=\"https:\/\/fonts.googleapis.com\/css2?family=Source+Serif+4:ital,wght@0,400;0,600;0,700;0,800;1,400&#038;family=Instrument+Sans:wght@400;500;600;700&#038;family=IBM+Plex+Mono:wght@400;500&#038;display=swap\" rel=\"stylesheet\">\n<style>:root{color-scheme:light dark;--bg-body:#F5F3EE;--bg-surface:#FFFFFF;--bg-recessed:#EDEAE4;--bg-code:#F0EDE7;--bg-th:#1C1C1C;--bg-tr-alt:#F8F6F2;--bg-callout-blue:#EBF3FD;--bg-callout-amber:#FFF8E6;--bg-callout-green:#E9F7EF;--c-body:#222222;--c-secondary:#4D4D4D;--c-tertiary:#777777;--c-inverse:#FFFFFF;--c-cn:#666666;--c-link:#9B5A12;--c-link-hover:#734210;--c-accent:#B8860B;--b-rule:#D8D5CE;--b-light:#E8E5DF;--b-accent:#B8860B;--b-table:#CBC8C1;--sh-sm:0 1px 2px rgba(0,0,0,0.05);--sh-md:0 3px 10px rgba(0,0,0,0.07);--sh-table:0 1px 4px rgba(0,0,0,0.06);--badge-bg:#1C1C1C;--badge-c:#FFFFFF;--hl-green:#E1F5E6;--hl-red:#FDE8E1;}@media(prefers-color-scheme:dark){:root{--bg-body:#111111;--bg-surface:#1A1A1A;--bg-recessed:#222222;--bg-code:#252525;--bg-th:#282828;--bg-tr-alt:#161616;--bg-callout-blue:#162030;--bg-callout-amber:#25200E;--bg-callout-green:#142218;--c-body:#E2E0DB;--c-secondary:#ADABA6;--c-tertiary:#888683;--c-inverse:#111111;--c-cn:#908E89;--c-link:#D9A63E;--c-link-hover:#EDC462;--c-accent:#D9A63E;--b-rule:#333333;--b-light:#2A2A2A;--b-accent:#D9A63E;--b-table:#363636;--sh-sm:0 1px 2px rgba(0,0,0,0.25);--sh-md:0 3px 10px rgba(0,0,0,0.35);--sh-table:0 1px 4px rgba(0,0,0,0.3);--badge-bg:#D9A63E;--badge-c:#111111;--hl-green:#16291A;--hl-red:#2A1714;}}*,*::before,*::after{box-sizing:border-box;margin:0;padding:0}html{font-size:16px;scroll-behavior:smooth}body{font-family:'Instrument Sans',-apple-system,BlinkMacSystemFont,sans-serif;background:var(--bg-body);color:var(--c-body);line-height:1.8}.page-wrap{max-width:880px;margin:0 auto;padding:2.5rem 1.25rem 4rem}.hdr{padding-bottom:2rem;margin-bottom:2.5rem;border-bottom:2px solid var(--b-accent)}.hdr .badge{display:inline-block;background:var(--badge-bg);color:var(--badge-c);font-size:.68rem;font-weight:700;letter-spacing:.12em;text-transform:uppercase;padding:.3em 1em;border-radius:2px;margin-bottom:1rem}.hdr h1{font-family:'Source Serif 4',Georgia,serif;font-weight:800;font-size:clamp(1.55rem,3.8vw,2.25rem);line-height:1.22;color:var(--c-body);margin-bottom:.65rem}.hdr .sub{font-size:1rem;color:var(--c-secondary);line-height:1.6;margin-bottom:.4rem}.hdr .sub-cn{font-size:.85rem;color:var(--c-cn);line-height:1.6;font-style:italic}.meta{display:flex;flex-wrap:wrap;gap:1rem;margin-top:1.1rem;font-size:.78rem;color:var(--c-tertiary)}.toc{background:var(--bg-surface);border:1px solid var(--b-rule);border-radius:4px;padding:1.2rem 1.4rem;margin-bottom:2.8rem;box-shadow:var(--sh-sm)}.toc-label{font-weight:700;font-size:.72rem;letter-spacing:.1em;text-transform:uppercase;color:var(--c-tertiary);margin-bottom:.55rem}.toc ol{list-style:none;counter-reset:tc;padding:0}.toc li{counter-increment:tc;margin-bottom:.25rem}.toc li::before{content:counter(tc) \".\";font-weight:600;font-family:'IBM Plex Mono',monospace;font-size:.78rem;margin-right:.45em;color:var(--c-tertiary)}.toc a{font-size:.86rem;color:var(--c-secondary);text-decoration:none}.toc a:hover{color:var(--c-link);text-decoration:underline}.body h2{font-family:'Instrument Sans',sans-serif;font-weight:700;font-size:1.32rem;color:var(--c-body);margin:2.8rem 0 .9rem;padding-bottom:.35rem;border-bottom:1px solid var(--b-light)}.body h3{font-weight:600;font-size:1.05rem;color:var(--c-body);margin:1.7rem 0 .55rem}.body p{margin-bottom:1.15rem;color:var(--c-secondary)}.body .cn{font-size:.84rem;color:var(--c-cn);margin-top:-.55rem;margin-bottom:1.15rem;padding-left:1rem;border-left:2px solid var(--b-light);font-style:italic}.body a{color:var(--c-link);text-decoration:underline;text-underline-offset:2px}.body a:hover{color:var(--c-link-hover)}.body strong{font-weight:600;color:var(--c-body)}.p{font-family:'IBM Plex Mono','Consolas',monospace;font-size:.86em;background:var(--bg-code);padding:.12em .4em;border-radius:3px;color:var(--c-body);white-space:nowrap}.eq{display:block;text-align:center;font-family:'IBM Plex Mono',monospace;font-size:.95rem;padding:1rem;margin:1.2rem 0;background:var(--bg-recessed);border-radius:4px;color:var(--c-body)}.tw{width:100%;overflow-x:auto;margin:1.4rem 0 2rem;border:1px solid var(--b-table);border-radius:4px;box-shadow:var(--sh-table)}.tw table{width:100%;border-collapse:collapse;font-size:.86rem;line-height:1.5}.tw caption{text-align:left;font-weight:600;font-size:.78rem;letter-spacing:.04em;text-transform:uppercase;color:var(--c-tertiary);padding:.75rem 1rem .35rem;background:var(--bg-surface);border-bottom:1px solid var(--b-light)}.tw thead th{background:var(--bg-th);color:var(--c-inverse);font-weight:600;font-size:.76rem;letter-spacing:.03em;text-transform:uppercase;padding:.65rem 1rem;text-align:left;white-space:nowrap;border-bottom:2px solid var(--b-accent)}.tw tbody td{padding:.55rem 1rem;border-bottom:1px solid var(--b-light);color:var(--c-secondary);vertical-align:top}.tw tbody tr:nth-child(even){background:var(--bg-tr-alt)}.tw tbody tr:hover{background:var(--bg-callout-amber)}.tw tbody td:first-child{font-weight:500;color:var(--c-body);white-space:nowrap}.tw .g{background:var(--hl-green)}.tw .r{background:var(--hl-red)}.note{padding:1rem 1.2rem;margin:1.5rem 0;border-radius:0 4px 4px 0;font-size:.9rem;border-left:3px solid var(--b-accent)}.note.blue{background:var(--bg-callout-blue)}.note.amber{background:var(--bg-callout-amber)}.note.green{background:var(--bg-callout-green)}.note .nt{font-weight:700;font-size:.78rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-body);margin-bottom:.3rem}.note p{margin-bottom:.35rem}.refs{margin-top:2.8rem;padding-top:1.5rem;border-top:2px solid var(--b-rule)}.refs h2{font-size:1.08rem;margin-bottom:.9rem}.rl{list-style:none;counter-reset:rf;padding:0}.rl li{counter-increment:rf;font-size:.8rem;color:var(--c-tertiary);margin-bottom:.55rem;padding-left:2.2rem;position:relative;line-height:1.5}.rl li::before{content:\"[\" counter(rf) \"]\";position:absolute;left:0;font-weight:600;color:var(--c-secondary);font-family:'IBM Plex Mono',monospace;font-size:.75rem}.rl a{color:var(--c-link);word-break:break-all}.contact{background:var(--bg-recessed);border:1px solid var(--b-rule);border-radius:4px;padding:1.5rem;margin-top:2.5rem}.contact h3{font-size:.98rem;margin-bottom:.7rem;color:var(--c-body)}.cg{display:grid;grid-template-columns:repeat(auto-fit,minmax(210px,1fr));gap:.75rem}.ci{font-size:.83rem;color:var(--c-secondary);line-height:1.45}.ci .lb{font-weight:600;font-size:.7rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-tertiary);display:block;margin-bottom:.1rem}.ci a{color:var(--c-link);text-decoration:none}.ci a:hover{text-decoration:underline}.ft{margin-top:2rem;padding-top:1.5rem;border-top:1px solid var(--b-light);font-size:.75rem;color:var(--c-tertiary);text-align:center;line-height:1.55}@media(max-width:600px){.page-wrap{padding:1.2rem 1rem 3rem}.hdr h1{font-size:1.35rem}.tw{font-size:.8rem}.cg{grid-template-columns:1fr}}<\/style>\n<\/head>\n\n<body>\n<article class=\"page-wrap\" itemscope itemtype=\"https:\/\/schema.org\/TechArticle\">\n\n  <header class=\"hdr\">\n    <span class=\"badge\">Feichun Special Cable \u2014 Technical Blog<\/span>\n    <h1 itemprop=\"headline\">ThyssenKrupp Stacker Reclaimers: Matching VDE Mechanicals with 6.6\/6.6kV Australian Voltages<\/h1>\n    <p class=\"sub\">Complete Technical Guide to Matching VDE Mechanical Standards with 6.6\/6.6kV Australian Voltages for ThyssenKrupp Stacker Reclaimer Cables. High-Speed Reeling Performance Analysis (120\u2013160 m\/min), Anti-Torsion Design Requirements, Tensile Strength Specifications, AS\/NZS 2802 Compliance, Bulk Material Handling and Port Machinery Applications.<\/p>\n    <p class=\"sub-cn\">\u4e3a\u8482\u68ee\u514b\u864f\u4f2f\u5806\u53d6\u6599\u673a\u7535\u7f06\u5c06VDE\u673a\u68b0\u6807\u51c6\u4e0e6.6\/6.6kV\u6fb3\u6d32\u7535\u538b\u76f8\u5339\u914d\u7684\u5b8c\u6574\u6280\u672f\u6307\u5357\u3002\u9ad8\u901f\u5377\u7b52\u6027\u80fd\u5206\u6790(120-160 m\/min)\u3001\u9632\u626d\u8f6c\u8bbe\u8ba1\u8981\u6c42\u3001\u6297\u62c9\u5f3a\u5ea6\u89c4\u8303\u3001AS\/NZS 2802\u5408\u89c4\u6027\u3001\u6563\u8d27\u642c\u8fd0\u548c\u6e2f\u53e3\u673a\u68b0\u5e94\u7528\u3002<\/p>\n    <div class=\"meta\">\n      <span itemprop=\"author\" itemscope itemtype=\"https:\/\/schema.org\/Organization\"><span itemprop=\"name\">Anhui Feichun Special Cable Co., Ltd.<\/span><\/span>\n      <span>|<\/span>\n      <time itemprop=\"datePublished\" datetime=\"2026-03-05\">Mar 05, 2026<\/time>\n      <span>|<\/span>\n      <span>Reading time: ~30 min<\/span>\n    <\/div>\n  <\/header>\n\n  <nav class=\"toc\" aria-label=\"Table of Contents\">\n    <div class=\"toc-label\">Contents<\/div>\n    <ol>\n      <li><a href=\"#s1\">ThyssenKrupp Stacker Reclaimer Systems: Equipment Scale and Power Requirements<\/a><\/li>\n      <li><a href=\"#s2\">6.6\/6.6kV Australian Voltage Standard: Ungrounded vs TN Earthing Philosophy<\/a><\/li>\n      <li><a href=\"#s3\">VDE Mechanical Standards: Bridge to AS\/NZS Electrical Requirements<\/a><\/li>\n      <li><a href=\"#s4\">Complete Technical Specification: 6.6\/6.6kV Reeling Cable<\/a><\/li>\n      <li><a href=\"#s5\">High-Speed Performance: 120\u2013160 m\/min Travel Speed Capability<\/a><\/li>\n      <li><a href=\"#s6\">Anti-Torsion Design: Preventing Cable Twist During Continuous Reeling<\/a><\/li>\n      <li><a href=\"#s7\">Tensile Strength Analysis: 15\u201325 N\/mm\u00b2 Range and Reinforcement Options<\/a><\/li>\n      <li><a href=\"#s8\">Bending Radius and Dynamic Reeling Endurance<\/a><\/li>\n      <li><a href=\"#s9\">Electrical Performance: EPR Insulation and Semiconductive Screening<\/a><\/li>\n      <li><a href=\"#s10\">Sheath Material Engineering: CPE vs PUR for Harsh Port Environments<\/a><\/li>\n      <li><a href=\"#s11\">AS\/NZS 2802 Type 241\/275 Compliance and VDE 0250-813 Mechanical Equivalence<\/a><\/li>\n      <li><a href=\"#s12\">Conclusion: Integrated VDE-AS\/NZS Cable Solution for ThyssenKrupp<\/a><\/li>\n    <\/ol>\n  <\/nav>\n\n  <div class=\"body\" itemprop=\"articleBody\">\n\n    <h2 id=\"s1\">1. ThyssenKrupp Stacker Reclaimer Systems: Equipment Scale and Power Requirements<\/h2>\n\n    <p>ThyssenKrupp manufactures some of the world&#8217;s largest bulk material handling equipment, including stacker reclaimers that can handle thousands of tons of material (iron ore, coal, phosphate) daily in open-pit mining and port environments. These massive machines\u2014often exceeding 50+ meters in height and 300+ meters in length\u2014require electrical power in the megawatt range (5\u201315 MW typical for large stacker reclaimers) delivered via heavy-duty reeling cables that can withstand continuous deployment and rapid retraction.<\/p>\n\n    <p class=\"cn\">\u8482\u68ee\u514b\u864f\u4f2f\u5236\u9020\u4e16\u754c\u4e0a\u4e00\u4e9b\u6700\u5927\u7684\u6563\u8d27\u642c\u8fd0\u8bbe\u5907\uff0c\u5305\u62ec\u80fd\u591f\u6bcf\u5929\u5904\u7406\u6570\u5343\u5428\u7269\u6599(\u94c1\u77ff\u77f3\u3001\u7164\u70ad\u3001\u78f7\u9178\u76d0)\u7684\u5806\u53d6\u6599\u673a\uff0c\u5728\u9732\u5929\u91c7\u77ff\u548c\u6e2f\u53e3\u73af\u5883\u4e2d\u8fd0\u884c\u3002\u8fd9\u4e9b\u5e9e\u5927\u673a\u5668\u2014\u2014\u901a\u5e38\u8d85\u8fc750\u7c73\u9ad8\u3001300\u591a\u7c73\u957f\u2014\u2014\u9700\u8981\u5146\u74e6\u7ea7\u7535\u529b(\u5178\u578b\u5927\u578b\u5806\u53d6\u6599\u673a5-15\u5146\u74e6)\uff0c\u901a\u8fc7\u80fd\u591f\u627f\u53d7\u8fde\u7eed\u90e8\u7f72\u548c\u5feb\u901f\u6536\u56de\u7684\u91cd\u578b\u5377\u7b52\u7535\u7f06\u4f20\u8f93\u3002<\/p>\n\n    <p><strong>System Architecture:<\/strong> A large stacker reclaimer comprises: (1) main structure (steel boom, buckets, conveyor systems), (2) electric motors (ranging from 300 kW to several megawatts), (3) reeling drum system with cable capacity 1000+ meters, (4) high-speed gearbox and transmission system enabling 120\u2013160 m\/min travel speed. The electrical power system typically operates at 6.6kV nominal (sometimes 11kV for the largest systems), with power distribution from the mine substation to the mobile reclaimer through trailing cables that must flex continuously.<\/p>\n\n    <h2 id=\"s2\">2. 6.6\/6.6kV Australian Voltage Standard: Ungrounded vs TN Earthing Philosophy<\/h2>\n\n    <p>Australian mining and port operations typically employ 6.6kV ungrounded (high-impedance grounded) systems to enable continued equipment operation during single-phase earth faults. This differs fundamentally from European TN systems where the neutral is directly grounded.<\/p>\n\n    <p><strong>Ungrounded System Design:<\/strong> When a single-phase earth fault occurs, the system remains energized because the neutral is not grounded. Equipment can continue operating while fault location and repair are arranged. This operational continuity is essential for massive equipment like stacker reclaimers\u2014sudden shutdown mid-operation leaves tons of suspended material and creates safety hazards.<\/p>\n\n    <p><strong>Voltage Stress Analysis:<\/strong> In an ungrounded 6.6kV system, during a phase-to-ground fault, healthy phases experience sustained voltage rise to approximately 6.6kV phase-to-earth (100% design stress if cable rated 6.6\/6.6kV). This requires cable insulation designed for symmetric phase-to-earth stress\u2014the 6.6\/6.6kV Uo=U rating ensures this design margin. European 6\/10kV cables (where Uo = 6\/\u221a3 \u2248 3.5kV phase-to-earth) would be inadequate for Australian ungrounded systems and must be upgraded.<\/p>\n\n    <h2 id=\"s3\">3. VDE Mechanical Standards: Bridge to AS\/NZS Electrical Requirements<\/h2>\n\n    <p>ThyssenKrupp&#8217;s engineering specifications typically reference VDE 0250-813 mechanical standards\u2014these define cable flexibility, tensile strength, bending radius, and reeling performance. However, Australian deployment requires these mechanical capabilities to be combined with AS\/NZS electrical standards (voltage rating, insulation thickness, screening).<\/p>\n\n    <p><strong>Mechanical Standards Alignment:<\/strong> VDE 0250-813 Type NTSCGEW\u00d6U cables are engineered for high mechanical stress: Class 5 fine-stranded copper for flexibility, 15\u201325 N\/mm\u00b2 tensile strength depending on sheath material, anti-torsion braiding for high-speed reeling, bending radius 12\u201315\u00d7 outer diameter for dynamic operation. These mechanical capabilities exactly match the requirements of Australian AS\/NZS 2802 Type 241\/275 cables when the electrical specifications (6.6\/6.6kV rating) are appropriately modified.<\/p>\n\n    <p><strong>Integrated Engineering Approach:<\/strong> Feichun and other premium manufacturers address this dual-standard requirement by: (1) using VDE-standard mechanical design (Class 5 stranded copper, high-strength sheath materials, anti-torsion reinforcement), (2) applying AS\/NZS electrical specifications (6.6\/6.6kV Uo=U voltage rating, appropriate insulation thickness for Australian ungrounded systems), (3) combining these in a single cable specification that satisfies both VDE mechanical performance and AS\/NZS electrical safety requirements.<\/p>\n\n    <h2 id=\"s4\">4. Complete Technical Specification: 6.6\/6.6kV Reeling Cable<\/h2>\n\n    <div class=\"tw\">\n      <caption>Table 1 \u2014 ThyssenKrupp 6.6\/6.6kV Reeling Cable: VDE Mechanics + AS\/NZS Electrical<\/caption>\n      <table>\n        <thead>\n          <tr>\n            <th>Parameter | \u53c2\u6570<\/th>\n            <th>Value | \u6570\u503c<\/th>\n            <th>Unit | \u5355\u4f4d<\/th>\n            <th>Notes | \u8bf4\u660e<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>Voltage Rating (Uo\/U)<\/td>\n            <td class=\"g\">6.6 \/ 6.6<\/td>\n            <td>kV<\/td>\n            <td>Ungrounded system (Uo=U)<\/td>\n          <\/tr>\n          <tr>\n            <td>Conductor Configuration (typical)<\/td>\n            <td class=\"g\">3 \u00d7 95 + 3 \u00d7 50\/3<\/td>\n            <td>mm\u00b2<\/td>\n            <td>Power + interstitial earth<\/td>\n          <\/tr>\n          <tr>\n            <td>Outer Diameter<\/td>\n            <td class=\"g\">72.0 &#8211; 78.0<\/td>\n            <td>mm<\/td>\n            <td>Compact for high-speed reel<\/td>\n          <\/tr>\n          <tr>\n            <td>Copper Weight<\/td>\n            <td class=\"g\">~3,600<\/td>\n            <td>kg\/km<\/td>\n            <td>Conductor total<\/td>\n          <\/tr>\n          <tr>\n            <td>Total Cable Weight<\/td>\n            <td class=\"g\">~7,800 &#8211; 8,400<\/td>\n            <td>kg\/km<\/td>\n            <td>Insulation + sheath<\/td>\n          <\/tr>\n          <tr>\n            <td>Ampacity (30\u00b0C)<\/td>\n            <td class=\"g\">~340<\/td>\n            <td>A<\/td>\n            <td>Per phase continuous<\/td>\n          <\/tr>\n          <tr>\n            <td>Max Tensile Load (EPR)<\/td>\n            <td class=\"g\">~4,275<\/td>\n            <td>N<\/td>\n            <td>15 N\/mm\u00b2 baseline<\/td>\n          <\/tr>\n          <tr>\n            <td>Max Tensile Load (PUR + Kevlar)<\/td>\n            <td class=\"g\">~7,125<\/td>\n            <td>N<\/td>\n            <td>25 N\/mm\u00b2 with reinforcement<\/td>\n          <\/tr>\n          <tr>\n            <td>Max Travel Speed<\/td>\n            <td class=\"g\">160<\/td>\n            <td>m\/min<\/td>\n            <td>High-speed reel capability<\/td>\n          <\/tr>\n          <tr>\n            <td>Min Bending Radius (Dynamic)<\/td>\n            <td class=\"g\">~900 &#8211; 1,170<\/td>\n            <td>mm<\/td>\n            <td>12-15\u00d7 outer diameter<\/td>\n          <\/tr>\n          <tr>\n            <td>Torsional Resistance<\/td>\n            <td class=\"g\">\u00b125 to \u00b150<\/td>\n            <td>\u00b0\/m<\/td>\n            <td>With anti-torsion braid<\/td>\n          <\/tr>\n          <tr>\n            <td>Insulation Material<\/td>\n            <td class=\"g\">EPR Type 3GI3<\/td>\n            <td>\u2014<\/td>\n            <td>90\u00b0C continuous rating<\/td>\n          <\/tr>\n          <tr>\n            <td>Sheath Material<\/td>\n            <td class=\"g\">CPE\/PUR heavy-duty<\/td>\n            <td>\u2014<\/td>\n            <td>VDE 0207 Part 21 compliance<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <h2 id=\"s5\">5. High-Speed Performance: 120\u2013160 m\/min Travel Speed Capability<\/h2>\n\n    <p>Modern ThyssenKrupp stacker reclaimers operate at 120\u2013160 m\/min horizontal travel speed\u2014significantly faster than traditional mining equipment. This extreme speed requirement drives cable design toward materials and configurations that tolerate continuous mechanical stress at high velocity.<\/p>\n\n    <p><strong>Speed-Induced Fatigue:<\/strong> At 150 m\/min, a 1000-meter cable deployment takes approximately 6.7 minutes. During this period, the cable experiences continuous bending stress as it unwinds from the reel. The bending radius and cable material must be optimized to prevent insulation cracking and conductor fatigue. EPR sheath material (softer, more flexible) is suitable for speed up to 120 m\/min; PUR sheath (harder, more durable) is specified for 150\u2013160 m\/min operation.<\/p>\n\n    <p><strong>Mechanical Derating During High-Speed Operation:<\/strong> Cable ampacity reduces during high-speed reeling due to reduced convective cooling and friction heating. Typical derating factor at 160 m\/min is 0.70\u20130.75 (versus 0.80\u20130.85 for standard speed operation). A 340A cable derates to approximately 240\u2013255A during high-speed continuous operation. System design must account for this reduction.<\/p>\n\n    <h2 id=\"s6\">6. Anti-Torsion Design: Preventing Cable Twist During Continuous Reeling<\/h2>\n\n    <p>High-speed reeling creates rotational (torsional) stress that can cause cable twisting\u2014a major failure mode. Anti-torsion reinforcement prevents this mechanical failure.<\/p>\n\n    <p><strong>Torsional Stress Mechanism:<\/strong> As cable unwinds from a reel rotating at high speed, tension and rotational forces create stress that tends to rotate the cable axis. Without reinforcement, this rotation manifests as cable twisting, which separates insulation from conductor (&#8220;bird-caging&#8221;) and creates internal short circuits. Torsional resistance specifications typically require \u00b125\u00b0\/m (maximum twist angle per meter of cable) for standard duty, \u00b150\u00b0\/m for extreme duty applications.<\/p>\n\n    <p><strong>Reinforcement Materials:<\/strong> Premium cables include polyamide (nylon) or aramid (Kevlar) braiding embedded between insulation and outer sheath. This reinforcement adds approximately 10\u201315% to cable cost but extends service life substantially under high-speed operation. For ThyssenKrupp equipment, this reinforcement is typically mandatory.<\/p>\n\n    <h2 id=\"s7\">7. Tensile Strength Analysis: 15\u201325 N\/mm\u00b2 Range and Reinforcement Options<\/h2>\n\n    <p>Tensile strength defines the maximum pulling force cable can withstand during installation or emergency situations. The range 15\u201325 N\/mm\u00b2 reflects material choices and reinforcement options.<\/p>\n\n    <p><strong>EPR Baseline (15 N\/mm\u00b2):<\/strong> Standard EPR sheath provides approximately 15 N\/mm\u00b2 tensile strength. For a 3\u00d795 mm\u00b2 configuration, maximum safe pulling force is approximately 3 \u00d7 95 \u00d7 15 = 4,275 N (437 kg-force). This is adequate for normal installation and operation.<\/p>\n\n    <p><strong>PUR + Kevlar Enhancement (25 N\/mm\u00b2):<\/strong> Polyurethane sheath combined with aramid (Kevlar) anti-torsion braiding achieves approximately 25 N\/mm\u00b2 tensile strength. For the same configuration, maximum pulling force increases to 7,125 N (727 kg-force)\u2014a 67% increase. This enhancement is specified when installation environment creates high pulling forces or when emergency cable recovery scenarios demand maximum strength.<\/p>\n\n    <h2 id=\"s8\">8. Bending Radius and Dynamic Reeling Endurance<\/h2>\n\n    <p>Continuous reeling imposes strict bending radius limits. Cables bent too sharply experience insulation compression that leads to electrical tree formation and eventual breakdown.<\/p>\n\n    <p><strong>Specification Requirement:<\/strong> Minimum bending radius for dynamic reeling is typically 12\u201315\u00d7 outer diameter (75 mm typical outer diameter yields 900\u20131,125 mm minimum radius). The reel pulley system must be designed with minimum radius at least 1.2\u00d7 this value to provide adequate safety margin.<\/p>\n\n    <p><strong>Reeling Endurance:<\/strong> Large stacker reclaimers may undergo 10,000\u201330,000 reeling cycles annually. Enhanced material systems (EPR Type 3GI3 insulation, heavy-duty sheath formulations) are specifically engineered for this volume of flexing, maintaining electrical and mechanical integrity throughout 5\u20137 year service life.<\/p>\n\n    <h2 id=\"s9\">9. Electrical Performance: EPR Insulation and Semiconductive Screening<\/h2>\n\n    <p>The 6.6\/6.6kV electrical rating requires careful insulation design and screening to manage high electric field strength around cable surface.<\/p>\n\n    <p><strong>EPR Type 3GI3 Insulation:<\/strong> Enhanced formulation provides: (1) dielectric strength 18\u201320 kV\/mm, (2) 90\u00b0C continuous conductor operating temperature, (3) superior aging resistance for extended service life, (4) partial discharge suppression for sustained 6.6kV voltage stress, (5) ozone resistance for any above-ground cable sections. Thickness typically 5.0\u20136.0 mm for 6.6kV rating, providing substantial safety margin for manufacturing tolerances and degradation during service.<\/p>\n\n    <p><strong>Semiconductive Screening Layers:<\/strong> The cable must include both internal (over conductor) and external (under outer sheath) semiconductive layers to create uniform electric field distribution. These layers are essential for: (1) preventing high electric stress at conductor surface, (2) ensuring safe equipment grounding and personnel protection, (3) compliance with AS\/NZS 2802 surface potential limitation requirements.<\/p>\n\n    <h2 id=\"s10\">10. Sheath Material Engineering: CPE vs PUR for Harsh Port Environments<\/h2>\n\n    <p>The choice between CPE (Chlorinated Polyethylene) and PUR (Polyurethane) outer sheath directly impacts cable durability in harsh port and mining environments.<\/p>\n\n    <p><strong>CPE Sheath Characteristics:<\/strong> Chlorinated polyethylene provides good mechanical properties and cost effectiveness. Advantages: abrasion resistance suitable for dragging across rough surfaces, good oil resistance, flame retardancy (V-0 per UL94), thermal stability -25\u00b0C to +80\u00b0C. Disadvantages: lower tensile strength (15 N\/mm\u00b2) compared to PUR, slightly reduced service life in UV-intensive environments.<\/p>\n\n    <p><strong>PUR Sheath Characteristics:<\/strong> Polyurethane offers superior properties for demanding applications. Advantages: exceptional tensile strength (25 N\/mm\u00b2), superior abrasion resistance (2\u20133\u00d7 better than CPE), extended operating temperature to 100\u00b0C, enhanced UV resistance when formulated with premium UV absorbers. Disadvantages: cost premium 30\u201350% over CPE, requires careful material selection for coastal salt-air environments (PUR can absorb moisture if not formulated correctly).<\/p>\n\n    <p><strong>Selection Decision:<\/strong> For standard open-pit mining applications, CPE is cost-optimal. For port environments with salt-air exposure or demanding high-speed applications, PUR is justified by extended service life and reduced maintenance interruptions.<\/p>\n\n    <h2 id=\"s11\">11. AS\/NZS 2802 Type 241\/275 Compliance and VDE 0250-813 Mechanical Equivalence<\/h2>\n\n    <p>Successful cable specification requires alignment with both Australian electrical standards (AS\/NZS 2802) and VDE mechanical standards (DIN VDE 0250-813).<\/p>\n\n    <p><strong>AS\/NZS 2802 Type 241 Electrical Requirements:<\/strong> (1) voltage rating 6.6\/6.6kV Uo=U for ungrounded systems, (2) conductor configuration 3 power + 3 interstitial earth per Type 241 structure, (3) flame retardancy per IEC 60332-1-2, (4) testing requirements (dielectric strength, insulation resistance, mechanical properties), (5) documentation (type test certificates, batch test reports).<\/p>\n\n    <p><strong>VDE 0250-813 Mechanical Equivalence:<\/strong> (1) Class 5 stranded copper conductors (AS\/NZS 1125 compatibility), (2) tensile strength minimum 15 N\/mm\u00b2 (baseline) or 25 N\/mm\u00b2 (with reinforcement), (3) bending radius 12\u201315\u00d7 outer diameter for dynamic reeling, (4) anti-torsion capability \u00b125\u00b0\/m standard or \u00b150\u00b0\/m premium, (5) material systems (EPR insulation, CPE\/PUR sheath) meeting VDE specifications.<\/p>\n\n    <h2 id=\"s12\">12. Conclusion: Integrated VDE-AS\/NZS Cable Solution for ThyssenKrupp<\/h2>\n\n    <p>ThyssenKrupp stacker reclaimer cable specifications represent the apex of integrated engineering\u2014combining VDE mechanical robustness with AS\/NZS electrical safety for Australian ungrounded power systems. The 6.6\/6.6kV rating ensures safe operation during earth faults while the VDE mechanical design (Class 5 stranding, high tensile strength, anti-torsion reinforcement) enables 120\u2013160 m\/min high-speed operation with extended service life.<\/p>\n\n    <p>Successful procurement requires: (1) explicit 6.6\/6.6kV Uo=U voltage rating, (2) Type 241 conductor structure, (3) enhanced EPR insulation and heavy-duty sheath materials, (4) anti-torsion reinforcement, (5) comprehensive testing documentation per both VDE and AS\/NZS standards. Feichun Special Cable manufactures integrated VDE-AS\/NZS cables engineered for ThyssenKrupp and other high-specification stacker reclaimer installations throughout Australian mining and port infrastructure.<\/p>\n\n  <\/div>\n\n  <section class=\"refs\">\n    <h2>References &#038; Sources<\/h2>\n    <ol class=\"rl\">\n      <li>DIN VDE 0250-813:2016, &#8220;Flexible cables \u2013 Part 813: Flexible cables for use with mining equipment,&#8221; Verband der Elektrotechnik Elektronik Informationstechnik.<\/li>\n      <li>AS\/NZS 2802:2009, &#8220;Electrical installations \u2013 Portable electrical equipment,&#8221; Standards New Zealand and Standards Australia.<\/li>\n      <li>AS\/NZS 1802:2012, &#8220;Rubber cables for underground mining applications,&#8221; Standards New Zealand and Standards Australia.<\/li>\n      <li>IEC 60502-2:2014, &#8220;Power cables with extruded insulation \u2013 Part 2: Cables for rated voltages from 6 kV to 30 kV,&#8221; International Electrotechnical Commission.<\/li>\n      <li>Feichun Special Cable Research &#038; Development Team, &#8220;6.6\/6.6kV High-Speed Reeling Cables: VDE Mechanics + AS\/NZS Electrical Specifications for Stacker Reclaimer Applications,&#8221; Technical Report, 2024.<\/li>\n    <\/ol>\n  <\/section>\n\n  <div class=\"contact\">\n    <h3>Contact Anhui Feichun Special Cable Co., Ltd.<\/h3>\n    <div class=\"cg\">\n      <div class=\"ci\">\n        <span class=\"lb\">6.6\/6.6kV Stacker Reclaimer &#038; Port Machinery Cables<\/span>\n        <a href=\"mailto:tech@feichuncables.com\" rel=\"nofollow\">tech@feichuncables.com<\/a>\n      <\/div>\n      <div class=\"ci\">\n        <span class=\"lb\">Australian Mining &#038; Port Equipment Support<\/span>\n        <a href=\"mailto:mining@feichuncables.com\" rel=\"nofollow\">mining@feichuncables.com<\/a>\n      <\/div>\n      <div class=\"ci\">\n        <span class=\"lb\">Sales &#038; Heavy Equipment Procurement<\/span>\n        <a href=\"mailto:sales@feichuncables.com\" rel=\"nofollow\">sales@feichuncables.com<\/a>\n      <\/div>\n      <div class=\"ci\">\n        <span class=\"lb\">WhatsApp \/ WeChat<\/span>\n        <a href=\"https:\/\/wa.me\/8613855123218\" rel=\"nofollow noopener\" target=\"_blank\">+86 138-5512-3218<\/a>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <footer class=\"ft\">\n    <p>&copy; 2026 Anhui Feichun Special Cable Co., Ltd. \u2014 All rights reserved.<\/p>\n    <p>Building A, Private Science &#038; Technology Park, Hefei Economic and Technological Development Zone, Anhui Province, China.<\/p>\n    <p><strong>SEO Keywords:<\/strong> ThyssenKrupp stacker reclaimer cable, 6.6kV reeling cable, 6.6\/6.6kV mining cable, medium voltage reeling cable, AS\/NZS 2802 cable, Type 241 trailing cable, Type 275 reeling cable, VDE 0250-813, NTSCGEW\u00d6U 6\/10kV, Australian mining cable, flexible MV cable, bulk material handling cable, port machinery cable, heavy duty reeling cable, stacker reclaimer power supply, drum reeling cable, mining dragline cable, ship unloader cable, bucket wheel excavator cable, high tensile reeling cable, flexible trailing cable, EPR insulated mining cable, PUR sheathed reeling cable, CPE mining cable, 6.6kV flexible cable, ThyssenKrupp spare parts, mining equipment cable replacement, medium voltage flexible copper cable, AS\/NZS mining standards, continuous miner cable, flexible heavy duty power cable, trailing cable ampacity, reeling cable dimensions, outer diameter reeling cable, torsion resistant cable, UV resistant mining cable, abrasion resistant power cable, VDE standard flexible cable, industrial reeling solutions, festoon system cable, mono spiral drum cable, multi layer drum reeling, AS\/NZS 1125 conductors, AS\/NZS 3808 insulation, customized mining cable, open pit mining cable, surface mining trailing cable, high speed reeling cable, flexible mining cable manufacturer, heavy duty port cable.<\/p>\n  <\/footer>\n\n<\/article>\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"ThyssenKrupp manufactures some of the world&#8217;s largest bulk material handling equipment, including stacker reclaimers that can handle thousands of tons of material (iron ore, coal, phosphate) daily in open-pit mining and port environments. These massive machines\u2014often exceeding 50+ meters in height and 300+ meters in length\u2014require electrical power in the megawatt range (5\u201315 MW typical for large stacker reclaimers) delivered via heavy-duty reeling cables that can withstand continuous deployment and rapid retraction.\n\u8482\u68ee\u514b\u864f\u4f2f\u5236\u9020\u4e16\u754c\u4e0a\u4e00\u4e9b\u6700\u5927\u7684\u6563\u8d27\u642c\u8fd0\u8bbe\u5907\uff0c\u5305\u62ec\u80fd\u591f\u6bcf\u5929\u5904\u7406\u6570\u5343\u5428\u7269\u6599(\u94c1\u77ff\u77f3\u3001\u7164\u70ad\u3001\u78f7\u9178\u76d0)\u7684\u5806\u53d6\u6599\u673a\uff0c\u5728\u9732\u5929\u91c7\u77ff\u548c\u6e2f\u53e3\u73af\u5883\u4e2d\u8fd0\u884c\u3002\u8fd9\u4e9b\u5e9e\u5927\u673a\u5668\u2014\u2014\u901a\u5e38\u8d85\u8fc750\u7c73\u9ad8\u3001300\u591a\u7c73\u957f\u2014\u2014\u9700\u8981\u5146\u74e6\u7ea7\u7535\u529b(\u5178\u578b\u5927\u578b\u5806\u53d6\u6599\u673a5-15\u5146\u74e6)\uff0c\u901a\u8fc7\u80fd\u591f\u627f\u53d7\u8fde\u7eed\u90e8\u7f72\u548c\u5feb\u901f\u6536\u56de\u7684\u91cd\u578b\u5377\u7b52\u7535\u7f06\u4f20\u8f93\u3002\nSystem Architecture: A large stacker reclaimer comprises: (1) main structure (steel boom, buckets, conveyor systems), (2) electric motors (ranging from 300 kW to several megawatts), (3) reeling drum system with cable capacity 1000+ meters, (4) high-speed gearbox and transmission system enabling 120\u2013160 m\/min travel speed. The electrical power system typically operates at 6.6kV nominal (sometimes 11kV for the largest systems), with power distribution from the mine substation to the mobile reclaimer through trailing cables that must flex continuously.","protected":false},"author":1,"featured_media":8469,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[222,66],"tags":[45922,45752,34128,4787,46087,3707,4155,46086,3705,3715,5327,1114,5303,45969,2618,3320,1685,46082,28558,5595,809,45010,32764,3950,32087,43590,45039,166,835,46080,46085,46084,31698,1951,44307,1032,8971,43588,2782,46083,5863,46081,46079,766,45833,34695,44981,3579,140,3037],"class_list":["post-8468","post","type-post","status-publish","format-standard","has-post-thumbnail","category-as-nzs-1802-reeling-cables-for-underground-mining","category-common-problems-encountered-in-cable-applications","tag-6-6-6-6kv-mining-cable","tag-6-6kv-flexible-cable","tag-6-6kv-reeling-cable","tag-abrasion-resistant-power-cable","tag-as-nzs-1125-conductors","tag-as-nzs-2802-cable","tag-as-nzs-3808-insulation","tag-as-nzs-mining-standards","tag-australian-mining-cable","tag-bucket-wheel-excavator-cable","tag-bulk-material-handling-cable","tag-continuous-miner-cable","tag-cpe-mining-cable","tag-customized-mining-cable","tag-drum-reeling-cable","tag-epr-insulated-mining-cable","tag-festoon-system-cable","tag-flexible-heavy-duty-power-cable","tag-flexible-mining-cable-manufacturer","tag-flexible-mv-cable","tag-flexible-trailing-cable","tag-heavy-duty-port-cable","tag-heavy-duty-reeling-cable-2","tag-high-speed-reeling-cable","tag-high-tensile-reeling-cable","tag-industrial-reeling-solutions","tag-medium-voltage-flexible-copper-cable","tag-medium-voltage-reeling-cable","tag-mining-dragline-cable","tag-mining-equipment-cable-replacement","tag-mono-spiral-drum-cable","tag-multi-layer-drum-reeling","tag-ntscgewou-6-10kv-2","tag-open-pit-mining-cable-2","tag-outer-diameter-reeling-cable","tag-port-machinery-cable","tag-pur-sheathed-reeling-cable","tag-reeling-cable-dimensions","tag-ship-unloader-cable","tag-stacker-reclaimer-power-supply","tag-surface-mining-trailing-cable","tag-thyssenkrupp-spare-parts","tag-thyssenkrupp-stacker-reclaimer-cable","tag-torsion-resistant-cable","tag-trailing-cable-ampacity","tag-type-241-trailing-cable","tag-type-275-reeling-cable","tag-uv-resistant-mining-cable","tag-vde-0250-813","tag-vde-standard-flexible-cable","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/8468","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=8468"}],"version-history":[{"count":1,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/8468\/revisions"}],"predecessor-version":[{"id":8470,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/8468\/revisions\/8470"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/8469"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=8468"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=8468"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=8468"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}