{"id":8427,"date":"2026-03-05T14:48:19","date_gmt":"2026-03-05T06:48:19","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=8427"},"modified":"2026-03-05T14:48:23","modified_gmt":"2026-03-05T06:48:23","slug":"phase-to-earth-voltage-decoding-uo-rating-on-australian-ntskcgewou-6-6-6-6kv-boms","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/phase-to-earth-voltage-decoding-uo-rating-on-australian-ntskcgewou-6-6-6-6kv-boms\/","title":{"rendered":"Phase-to-Earth Voltage: Decoding &#8220;Uo&#8221; Rating on Australian (N)TSKCGEW\u00d6U 6.6\/6.6kV BOMs"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Complete Technical Guide to Understanding Phase-to-Earth Voltage Notation on Australian Mining Cable Bill of Materials. Why 6.6\/6.6kV Instead of 3.8\/6.6kV, IT Earthing System Philosophy, Single-Phase Earth Fault Voltage Shift Analysis, BOM Decoding for Procurement Engineers, Mechanical Stress Parameters, Tensile Load Calculations, Short-Circuit Current Data, Dynamic Operation Limits, Cable Testing and Commissioning Requirements.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6fb3\u6d32\u77ff\u7528\u7535\u7f06\u7269\u6599\u6e05\u5355(BOM)\u4e0a\u7406\u89e3\u76f8\u5bf9\u5730\u7535\u538b\u6807\u8bc6\u7684\u5b8c\u6574\u6280\u672f\u6307\u5357\u3002\u4e3a\u4ec0\u4e48\u662f6.6\/6.6kV\u800c\u4e0d\u662f3.8\/6.6kV\u3001IT\u63a5\u5730\u7cfb\u7edf\u7406\u5ff5\u3001\u5355\u76f8\u63a5\u5730\u6545\u969c\u7535\u538b\u504f\u79fb\u5206\u6790\u3001BOM\u91c7\u8d2d\u5de5\u7a0b\u5e08\u89e3\u8bfb\u3001\u673a\u68b0\u5e94\u529b\u53c2\u6570\u3001\u62c9\u4f38\u8d1f\u8377\u8ba1\u7b97\u3001\u77ed\u8def\u7535\u6d41\u6570\u636e\u3001\u52a8\u6001\u8fd0\u884c\u9650\u5236\u3001\u7535\u7f06\u6d4b\u8bd5\u4e0e\u8c03\u8bd5\u8981\u6c42\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-dominant-color=\"4b4949\" data-has-transparency=\"false\" style=\"--dominant-color: #4b4949;\" loading=\"lazy\" decoding=\"async\" width=\"1051\" height=\"628\" sizes=\"auto, (max-width: 1051px) 100vw, 1051px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-948-1051x628.avif\" alt=\"\" class=\"wp-image-8428 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-948-1051x628.avif 1051w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-948-300x179.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-948-768x459.avif 768w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-948-400x239.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-948-800x478.avif 800w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-948-832x497.avif 832w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-948.avif 1118w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n<title>Phase-to-Earth Voltage: Decoding &#8220;Uo&#8221; Rating on Australian (N)TSKCGEW\u00d6U 6.6\/6.6kV BOMs | Feichun Cable<\/title>\n<meta name=\"description\" content=\"Complete technical guide: Understanding phase-to-earth voltage (Uo) notation on Australian 6.6\/6.6kV medium voltage cables. BOM decoding, IT earthing system implications, single-phase earth fault voltage shift, why 6.6\/6.6kV instead of 3.8\/6.6kV, mechanical stress parameters, short-circuit data, AS\/NZS 1802\/2802 compliance for mining cables.\">\n<meta name=\"keywords\" content=\"phase-to-earth voltage, Uo rating 6.6kV, TSKCGEWOU cable, 6.6\/6.6kV medium voltage, Australian mining cable BOM, IT earthing system cable, AS\/NZS 1802 trailing cable, earth fault protection cable, cable voltage rating notation, reeling cable specifications, medium voltage cable parameters, EPR 3GI3 insulation, 5GM5 outer sheath, heavy duty reeling cable, dragline cable, bucket wheel cable, port machinery cable, cable short circuit rating, tensile strength cable, bending radius reeling, torsional stress cable, cable mechanical properties, Class 5 stranded copper, mining equipment power cable, industrial rubber cable, cable ampacity derating, cable traveling speed, cable test voltage, earth continuity monitoring cable, high voltage mining cable, cable outer diameter dimensions, cable weight specifications, copper conductor cable, cable cost specification, cable procurement BOM, cable technical datasheet, cable supplier Australia, reeling drum cable, cable design standard VDE, cable design standard AS\/NZS, cable engineering calculation, cable field installation, cable commissioning test, cable reliability mining, cable durability harsh environment, cable supply chain, cable logistics freight, cable inventory management\">\n<meta name=\"author\" content=\"Anhui Feichun Special Cable Co., Ltd.\">\n<link rel=\"canonical\" href=\"https:\/\/feichuncables.com\/blog\/phase-to-earth-voltage-uo-rating-6-6kv\/\">\n\n<link rel=\"preconnect\" href=\"https:\/\/fonts.googleapis.com\">\n<link rel=\"preconnect\" href=\"https:\/\/fonts.gstatic.com\" crossorigin>\n<link href=\"https:\/\/fonts.googleapis.com\/css2?family=Source+Serif+4:ital,wght@0,400;0,600;0,700;0,800;1,400&#038;family=Instrument+Sans:wght@400;500;600;700&#038;family=IBM+Plex+Mono:wght@400;500&#038;display=swap\" rel=\"stylesheet\">\n\n<style>\n:root{color-scheme:light dark;--bg-body:#F5F3EE;--bg-surface:#FFFFFF;--bg-recessed:#EDEAE4;--bg-code:#F0EDE7;--bg-th:#1C1C1C;--bg-tr-alt:#F8F6F2;--bg-callout-blue:#EBF3FD;--bg-callout-amber:#FFF8E6;--bg-callout-green:#E9F7EF;--c-body:#222222;--c-secondary:#4D4D4D;--c-tertiary:#777777;--c-inverse:#FFFFFF;--c-cn:#666666;--c-link:#9B5A12;--c-link-hover:#734210;--c-accent:#B8860B;--b-rule:#D8D5CE;--b-light:#E8E5DF;--b-accent:#B8860B;--b-table:#CBC8C1;--sh-sm:0 1px 2px rgba(0,0,0,0.05);--sh-md:0 3px 10px rgba(0,0,0,0.07);--sh-table:0 1px 4px rgba(0,0,0,0.06);--badge-bg:#1C1C1C;--badge-c:#FFFFFF;--tag-bg:#EDEAE4;--tag-c:#555;--hl-green:#E1F5E6;--hl-red:#FDE8E1;}@media(prefers-color-scheme:dark){:root{--bg-body:#111111;--bg-surface:#1A1A1A;--bg-recessed:#222222;--bg-code:#252525;--bg-th:#282828;--bg-tr-alt:#161616;--bg-callout-blue:#162030;--bg-callout-amber:#25200E;--bg-callout-green:#142218;--c-body:#E2E0DB;--c-secondary:#ADABA6;--c-tertiary:#888683;--c-inverse:#111111;--c-cn:#908E89;--c-link:#D9A63E;--c-link-hover:#EDC462;--c-accent:#D9A63E;--b-rule:#333333;--b-light:#2A2A2A;--b-accent:#D9A63E;--b-table:#363636;--sh-sm:0 1px 2px rgba(0,0,0,0.25);--sh-md:0 3px 10px rgba(0,0,0,0.35);--sh-table:0 1px 4px rgba(0,0,0,0.3);--badge-bg:#D9A63E;--badge-c:#111111;--tag-bg:#282828;--tag-c:#ADABA6;--hl-green:#16291A;--hl-red:#2A1714;}}*,*::before,*::after{box-sizing:border-box;margin:0;padding:0}html{font-size:16px;scroll-behavior:smooth}body{font-family:'Instrument Sans',-apple-system,BlinkMacSystemFont,sans-serif;background:var(--bg-body);color:var(--c-body);line-height:1.8}.page-wrap{max-width:880px;margin:0 auto;padding:2.5rem 1.25rem 4rem}.hdr{padding-bottom:2rem;margin-bottom:2.5rem;border-bottom:2px solid var(--b-accent)}.hdr .badge{display:inline-block;background:var(--badge-bg);color:var(--badge-c);font-size:.68rem;font-weight:700;letter-spacing:.12em;text-transform:uppercase;padding:.3em 1em;border-radius:2px;margin-bottom:1rem}.hdr h1{font-family:'Source Serif 4',Georgia,serif;font-weight:800;font-size:clamp(1.55rem,3.8vw,2.25rem);line-height:1.22;color:var(--c-body);margin-bottom:.65rem}.hdr .sub{font-size:1rem;color:var(--c-secondary);line-height:1.6;margin-bottom:.4rem}.hdr .sub-cn{font-size:.85rem;color:var(--c-cn);line-height:1.6;font-style:italic}.meta{display:flex;flex-wrap:wrap;gap:1rem;margin-top:1.1rem;font-size:.78rem;color:var(--c-tertiary)}.toc{background:var(--bg-surface);border:1px solid var(--b-rule);border-radius:4px;padding:1.2rem 1.4rem;margin-bottom:2.8rem;box-shadow:var(--sh-sm)}.toc-label{font-weight:700;font-size:.72rem;letter-spacing:.1em;text-transform:uppercase;color:var(--c-tertiary);margin-bottom:.55rem}.toc ol{list-style:none;counter-reset:tc;padding:0}.toc li{counter-increment:tc;margin-bottom:.25rem}.toc li::before{content:counter(tc) \".\";font-weight:600;font-family:'IBM Plex Mono',monospace;font-size:.78rem;margin-right:.45em;color:var(--c-tertiary)}.toc a{font-size:.86rem;color:var(--c-secondary);text-decoration:none}.toc a:hover{color:var(--c-link);text-decoration:underline}.body h2{font-family:'Instrument Sans',sans-serif;font-weight:700;font-size:1.32rem;color:var(--c-body);margin:2.8rem 0 .9rem;padding-bottom:.35rem;border-bottom:1px solid var(--b-light)}.body h3{font-weight:600;font-size:1.05rem;color:var(--c-body);margin:1.7rem 0 .55rem}.body p{margin-bottom:1.15rem;color:var(--c-secondary)}.body .cn{font-size:.84rem;color:var(--c-cn);margin-top:-.55rem;margin-bottom:1.15rem;padding-left:1rem;border-left:2px solid var(--b-light);font-style:italic}.body a{color:var(--c-link);text-decoration:underline;text-underline-offset:2px}.body a:hover{color:var(--c-link-hover)}.body strong{font-weight:600;color:var(--c-body)}.p{font-family:'IBM Plex Mono','Consolas',monospace;font-size:.86em;background:var(--bg-code);padding:.12em .4em;border-radius:3px;color:var(--c-body);white-space:nowrap}.eq{display:block;text-align:center;font-family:'IBM Plex Mono',monospace;font-size:.95rem;padding:1rem;margin:1.2rem 0;background:var(--bg-recessed);border-radius:4px;color:var(--c-body)}.tw{width:100%;overflow-x:auto;margin:1.4rem 0 2rem;border:1px solid var(--b-table);border-radius:4px;box-shadow:var(--sh-table)}.tw table{width:100%;border-collapse:collapse;font-size:.86rem;line-height:1.5}.tw caption{text-align:left;font-weight:600;font-size:.78rem;letter-spacing:.04em;text-transform:uppercase;color:var(--c-tertiary);padding:.75rem 1rem .35rem;background:var(--bg-surface);border-bottom:1px solid var(--b-light)}.tw thead th{background:var(--bg-th);color:var(--c-inverse);font-weight:600;font-size:.76rem;letter-spacing:.03em;text-transform:uppercase;padding:.65rem 1rem;text-align:left;white-space:nowrap;border-bottom:2px solid var(--b-accent)}.tw tbody td{padding:.55rem 1rem;border-bottom:1px solid var(--b-light);color:var(--c-secondary);vertical-align:top}.tw tbody tr:nth-child(even){background:var(--bg-tr-alt)}.tw tbody tr:hover{background:var(--bg-callout-amber)}.tw tbody td:first-child{font-weight:500;color:var(--c-body);white-space:nowrap}.tw .g{background:var(--hl-green)}.tw .r{background:var(--hl-red)}.note{padding:1rem 1.2rem;margin:1.5rem 0;border-radius:0 4px 4px 0;font-size:.9rem;border-left:3px solid var(--b-accent)}.note.blue{background:var(--bg-callout-blue)}.note.amber{background:var(--bg-callout-amber)}.note.green{background:var(--bg-callout-green)}.note .nt{font-weight:700;font-size:.78rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-body);margin-bottom:.3rem}.note p{margin-bottom:.35rem}.refs{margin-top:2.8rem;padding-top:1.5rem;border-top:2px solid var(--b-rule)}.refs h2{font-size:1.08rem;margin-bottom:.9rem}.rl{list-style:none;counter-reset:rf;padding:0}.rl li{counter-increment:rf;font-size:.8rem;color:var(--c-tertiary);margin-bottom:.55rem;padding-left:2.2rem;position:relative;line-height:1.5}.rl li::before{content:\"[\" counter(rf) \"]\";position:absolute;left:0;font-weight:600;color:var(--c-secondary);font-family:'IBM Plex Mono',monospace;font-size:.75rem}.rl a{color:var(--c-link);word-break:break-all}.contact{background:var(--bg-recessed);border:1px solid var(--b-rule);border-radius:4px;padding:1.5rem;margin-top:2.5rem}.contact h3{font-size:.98rem;margin-bottom:.7rem;color:var(--c-body)}.cg{display:grid;grid-template-columns:repeat(auto-fit,minmax(210px,1fr));gap:.75rem}.ci{font-size:.83rem;color:var(--c-secondary);line-height:1.45}.ci .lb{font-weight:600;font-size:.7rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-tertiary);display:block;margin-bottom:.1rem}.ci a{color:var(--c-link);text-decoration:none}.ci a:hover{text-decoration:underline}.ft{margin-top:2rem;padding-top:1.5rem;border-top:1px solid var(--b-light);font-size:.75rem;color:var(--c-tertiary);text-align:center;line-height:1.55}@media(max-width:600px){.page-wrap{padding:1.2rem 1rem 3rem}.hdr h1{font-size:1.35rem}.tw{font-size:.8rem}.cg{grid-template-columns:1fr}}\n<\/style>\n<\/head>\n\n<body>\n<article class=\"page-wrap\" itemscope itemtype=\"https:\/\/schema.org\/TechArticle\">\n\n  <header class=\"hdr\">\n    <span class=\"badge\">Feichun Special Cable \u2014 Technical Blog<\/span>\n    <h1 itemprop=\"headline\">Phase-to-Earth Voltage: Decoding &#8220;Uo&#8221; Rating on Australian (N)TSKCGEW\u00d6U 6.6\/6.6kV BOMs<\/h1>\n    <p class=\"sub\">Complete Technical Guide to Understanding Phase-to-Earth Voltage Notation on Australian Mining Cable Bill of Materials. Why 6.6\/6.6kV Instead of 3.8\/6.6kV, IT Earthing System Philosophy, Single-Phase Earth Fault Voltage Shift Analysis, BOM Decoding for Procurement Engineers, Mechanical Stress Parameters, Tensile Load Calculations, Short-Circuit Current Data, Dynamic Operation Limits, Cable Testing and Commissioning Requirements.<\/p>\n    <p class=\"sub-cn\">\u6fb3\u6d32\u77ff\u7528\u7535\u7f06\u7269\u6599\u6e05\u5355(BOM)\u4e0a\u7406\u89e3\u76f8\u5bf9\u5730\u7535\u538b\u6807\u8bc6\u7684\u5b8c\u6574\u6280\u672f\u6307\u5357\u3002\u4e3a\u4ec0\u4e48\u662f6.6\/6.6kV\u800c\u4e0d\u662f3.8\/6.6kV\u3001IT\u63a5\u5730\u7cfb\u7edf\u7406\u5ff5\u3001\u5355\u76f8\u63a5\u5730\u6545\u969c\u7535\u538b\u504f\u79fb\u5206\u6790\u3001BOM\u91c7\u8d2d\u5de5\u7a0b\u5e08\u89e3\u8bfb\u3001\u673a\u68b0\u5e94\u529b\u53c2\u6570\u3001\u62c9\u4f38\u8d1f\u8377\u8ba1\u7b97\u3001\u77ed\u8def\u7535\u6d41\u6570\u636e\u3001\u52a8\u6001\u8fd0\u884c\u9650\u5236\u3001\u7535\u7f06\u6d4b\u8bd5\u4e0e\u8c03\u8bd5\u8981\u6c42\u3002<\/p>\n    <div class=\"meta\">\n      <span itemprop=\"author\" itemscope itemtype=\"https:\/\/schema.org\/Organization\"><span itemprop=\"name\">Anhui Feichun Special Cable Co., Ltd.<\/span><\/span>\n      <span>|<\/span>\n      <time itemprop=\"datePublished\" datetime=\"2026-03-05\">Mar 05, 2026<\/time>\n      <span>|<\/span>\n      <span>Reading time: ~31 min<\/span>\n    <\/div>\n  <\/header>\n\n  <nav class=\"toc\" aria-label=\"Table of Contents\">\n    <div class=\"toc-label\">Contents<\/div>\n    <ol>\n      <li><a href=\"#s1\">Decoding Uo\/U Notation: Standard International Cable Voltage Rating Convention<\/a><\/li>\n      <li><a href=\"#s2\">Why 6.6\/6.6kV Instead of 3.8\/6.6kV: The Australian IT Earthing Requirement<\/a><\/li>\n      <li><a href=\"#s3\">Single-Phase Earth Fault Voltage Shift: The Physics Behind Uo=U Design<\/a><\/li>\n      <li><a href=\"#s4\">Reading Australian Mining Cable BOMs: What 6.6\/6.6kV Tells Procurement Engineers<\/a><\/li>\n      <li><a href=\"#s5\">Complete Technical Specification: (N)TSKCGEW\u00d6U 6.6\/6.6kV Cable Range<\/a><\/li>\n      <li><a href=\"#s6\">Mechanical Properties: Tensile Load Calculations and Stress Limits<\/a><\/li>\n      <li><a href=\"#s7\">Dynamic Operation Parameters: Travel Speed, Torsional Stress, Bending Radius<\/a><\/li>\n      <li><a href=\"#s8\">Short-Circuit Behavior: Current Ratings and Thermal Limits<\/a><\/li>\n      <li><a href=\"#s9\">Material Systems: EPR 3GI3 Insulation and 5GM5 Outer Sheath<\/a><\/li>\n      <li><a href=\"#s10\">Cable Testing and Commissioning: Verifying Uo\/U Specifications in Field<\/a><\/li>\n      <li><a href=\"#s11\">BOM Cost Analysis: Understanding Price Drivers for 6.6\/6.6kV Cables<\/a><\/li>\n      <li><a href=\"#s12\">Conclusion: Uo Rating as Safety and Reliability Foundation<\/a><\/li>\n    <\/ol>\n  <\/nav>\n\n  <div class=\"body\" itemprop=\"articleBody\">\n\n    <h2 id=\"s1\">1. Decoding Uo\/U Notation: Standard International Cable Voltage Rating Convention<\/h2>\n\n    <p>The voltage rating notation on electrical cables follows a standard international convention established by IEC and VDE standards. When you see a cable rated <span class=\"p\">6.6\/6.6kV<\/span>, this notation encodes two critical electrical parameters that determine the cable&#8217;s safe operating limits.<\/p>\n\n    <p class=\"cn\">\u7535\u6c14\u7535\u7f06\u4e0a\u7684\u7535\u538b\u989d\u5b9a\u503c\u6807\u8bc6\u9075\u5faa\u7531IEC\u548cVDE\u6807\u51c6\u786e\u5b9a\u7684\u6807\u51c6\u56fd\u9645\u7ea6\u5b9a\u3002\u5f53\u60a8\u770b\u5230\u7535\u7f06\u989d\u5b9a\u4e3a6.6\/6.6kV\u65f6\uff0c\u6b64\u6807\u8bc6\u7f16\u7801\u4e86\u4e24\u4e2a\u5173\u952e\u7535\u6c14\u53c2\u6570\uff0c\u8fd9\u4e9b\u53c2\u6570\u51b3\u5b9a\u4e86\u7535\u7f06\u7684\u5b89\u5168\u5de5\u4f5c\u9650\u5236\u3002<\/p>\n\n    <p><strong>Uo (Phase-to-Earth Voltage):<\/strong> The first number in the Uo\/U notation represents the maximum phase-to-earth voltage (voltage between a phase conductor and ground or metal shielding) that the cable insulation is designed to withstand continuously. For a 6.6\/6.6kV cable, Uo = 6.6kV phase-to-earth.<\/p>\n\n    <p><strong>U (Phase-to-Phase Voltage):<\/strong> The second number represents the maximum phase-to-phase voltage (voltage between any two phase conductors) the cable can handle. For a 6.6\/6.6kV cable, U = 6.6kV phase-to-phase.<\/p>\n\n    <p><strong>Standard Relationship in TN Systems:<\/strong> In conventional European TN earthing systems (where the neutral is directly grounded at low impedance), the relationship between Uo and U is: Uo = U\/\u221a3 \u2248 0.577U. Therefore, a standard 6.6kV system would normally use 3.8\/6.6kV cables (since 6.6\/\u221a3 \u2248 3.8kV). However, Australian mining cables specify 6.6\/6.6kV, indicating a fundamentally different earthing system design.<\/p>\n\n    <h2 id=\"s2\">2. Why 6.6\/6.6kV Instead of 3.8\/6.6kV: The Australian IT Earthing Requirement<\/h2>\n\n    <p>The specification of 6.6\/6.6kV cables (rather than the more standard 3.8\/6.6kV) on Australian mining BOMs is a direct consequence of the IT (isolated neutral) earthing system philosophy that dominates Australian underground and surface mining operations.<\/p>\n\n    <p class=\"cn\">\u6fb3\u6d32\u77ff\u7528BOM\u4e2d6.6\/6.6kV\u7535\u7f06(\u800c\u4e0d\u662f\u66f4\u6807\u51c6\u76843.8\/6.6kV)\u7684\u89c4\u8303\u662f\u6fb3\u6d32\u5730\u4e0b\u548c\u9732\u5929\u77ff\u5c71\u8fd0\u8425\u5360\u4e3b\u5bfc\u5730\u4f4d\u7684IT(\u9694\u79bb\u4e2d\u6027\u70b9)\u63a5\u5730\u7cfb\u7edf\u7406\u5ff5\u7684\u76f4\u63a5\u7ed3\u679c\u3002<\/p>\n\n    <p><strong>IT System Design Philosophy:<\/strong> Australian mining standards (AS\/NZS 1802, AS\/NZS 2802) mandate IT earthing systems where the transformer&#8217;s neutral is isolated from ground or grounded through high impedance. This design choice enables continued operation during single-phase earth faults\u2014a critical safety feature in underground mining where unexpected power loss creates acute hazards (asphyxiation risk from ventilation loss, entrapment hazards, etc.).<\/p>\n\n    <p><strong>Operational Continuity Requirement:<\/strong> When a single-phase earth fault occurs in an IT system, the system does not automatically trip. Instead, it continues operating while mine personnel locate and repair the fault, typically over minutes to hours. This requires cable insulation designed to withstand prolonged fault-condition voltage stress that would destroy TN-system cables within minutes.<\/p>\n\n    <p><strong>The Voltage Stress Difference:<\/strong> During an IT system earth fault, the two healthy phases experience phase-to-earth voltage rising to approximately 87% of the line voltage. For a 6.6kV system, this is approximately 5.7kV sustained on each healthy phase. A 3.8\/6.6kV cable, rated only for 3.8kV phase-to-earth, experiences 150% overstress and fails catastrophically. A 6.6\/6.6kV cable, rated for 6.6kV phase-to-earth, experiences only 86% rated stress and operates safely with margin.<\/p>\n\n    <h2 id=\"s3\">3. Single-Phase Earth Fault Voltage Shift: The Physics Behind Uo=U Design<\/h2>\n\n    <p>The mathematical foundation for 6.6\/6.6kV cable design is the voltage redistribution that occurs during single-phase earth faults in IT systems. This analysis explains why the Uo=U specification is technically necessary, not merely a preference.<\/p>\n\n    <p><strong>Normal Operating Voltage Distribution:<\/strong> In a balanced three-phase 6.6kV system, each phase operates at 6.6\/\u221a3 \u2248 3.8kV phase-to-earth. The phase conductors form a symmetric voltage distribution relative to ground.<\/p>\n\n    <p><strong>Single-Phase Earth Fault Condition:<\/strong> When Phase A contacts earth, the voltage distribution fundamentally changes. The faulted phase voltage drops toward ground potential, but because the neutral is not solidly grounded (as in IT systems), the voltage cannot redistribute as it does in TN systems. Instead, the two healthy phases (B and C) see their voltage rise relative to ground.<\/p>\n\n    <div class=\"eq\">V_healthy_phase = 6.6kV \u00d7 \u221a(2\/3) \u2248 6.6kV \u00d7 0.816 \u2248 5.38kV<\/div>\n\n    <p>More precisely, during an IT system earth fault, each healthy phase voltage approaches approximately 86\u201387% of the line voltage relative to ground. For a 6.6kV system, this is approximately 5.7kV sustained phase-to-earth stress. This sustained stress (not brief transient stress as in TN systems) requires insulation rated Uo = 6.6kV to provide safe operation with design margin.<\/p>\n\n    <h2 id=\"s4\">4. Reading Australian Mining Cable BOMs: What 6.6\/6.6kV Tells Procurement Engineers<\/h2>\n\n    <p>For electrical engineers and procurement specialists reviewing Australian mining equipment BOMs, the 6.6\/6.6kV notation signals specific design requirements and material specifications that affect cable compatibility, cost, installation procedures, and supplier selection.<\/p>\n\n    <p class=\"cn\">\u5bf9\u4e8e\u5ba1\u67e5\u6fb3\u6d32\u77ff\u7528\u8bbe\u5907BOM\u7684\u7535\u6c14\u5de5\u7a0b\u5e08\u548c\u91c7\u8d2d\u4e13\u5bb6\uff0c6.6\/6.6kV\u6807\u8bc6\u8868\u793a\u7279\u5b9a\u7684\u8bbe\u8ba1\u8981\u6c42\u548c\u6750\u6599\u89c4\u683c\uff0c\u5f71\u54cd\u7535\u7f06\u517c\u5bb9\u6027\u3001\u6210\u672c\u3001\u5b89\u88c5\u7a0b\u5e8f\u548c\u4f9b\u5e94\u5546\u9009\u62e9\u3002<\/p>\n\n    <p><strong>Signal One: IT Earthing System Equipment:<\/strong> The 6.6\/6.6kV specification immediately indicates the equipment operates on an IT earthing system (isolated or high-impedance grounded neutral). This affects electrical system design, protective relay settings, fault clearing strategies, and personnel safety procedures\u2014all downstream from the cable specification.<\/p>\n\n    <p><strong>Signal Two: AS\/NZS Standard Compliance Implied:<\/strong> Australian 6.6\/6.6kV cables are designed to AS\/NZS 1802 or equivalent standards. European VDE 0.6\/1kV or even 3.8\/6.6kV cables are not acceptable substitutes, regardless of voltage rating similarity. This signals that suppliers must be qualified to Australian standards, potentially limiting available vendors and affecting delivery timelines.<\/p>\n\n    <p><strong>Signal Three: Material and Thickness Requirements:<\/strong> 6.6\/6.6kV rating requires: (1) insulation thickness approximately 3.0\u20133.5 mm per conductor (versus 1.5\u20132.0 mm for 3.8\/6.6kV cables), (2) enhanced EPR Type 3GI3 material systems with premium additive packages, (3) semi-conductive screens with tighter resistivity tolerances (100\u20131000 ohm-cm), and (4) heavy-duty PCP\/CPE outer sheath (5GM5 grade). These material upgrades increase cable cost 40\u201370% compared to standard voltage ratings.<\/p>\n\n    <p><strong>Signal Four: Mechanical Properties Impact:<\/strong> Thicker insulation and enhanced sheaths result in larger cable diameters, increased weight per kilometer, and higher mechanical stiffness. Procurement teams must verify that existing installation equipment (reels, pulleys, cable glands, terminal lugs) is compatible with these larger, heavier cables.<\/p>\n\n    <h2 id=\"s5\">5. Complete Technical Specification: (N)TSKCGEW\u00d6U 6.6\/6.6kV Cable Range<\/h2>\n\n    <p>The following specification table presents (N)TSKCGEW\u00d6U 6.6\/6.6kV cables for typical Australian mining and industrial applications. These specifications are the reference data engineers use for equipment design and procurement planning.<\/p>\n\n    <div class=\"tw\">\n      <caption>Table 1 \u2014 (N)TSKCGEW\u00d6U 6.6\/6.6kV Medium Voltage Reeling Cable<\/caption>\n      <table>\n        <thead>\n          <tr>\n            <th>Conductor Config. | \u5bfc\u4f53\u914d\u7f6e<\/th>\n            <th>Uo\/U | \u7b49\u7ea7<\/th>\n            <th>Outer \u00d8 (mm) | \u5916\u5f84<\/th>\n            <th>Cu Weight (kg\/km) | \u94dc\u91cd<\/th>\n            <th>Total Weight (kg\/km) | \u603b\u91cd<\/th>\n            <th>Ampacity (A)* | \u8f7d\u6d41\u91cf<\/th>\n            <th>Max Tensile (N\/mm\u00b2)<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>3\u00d735 + Earth<\/td>\n            <td class=\"g\">6.6 \/ 6.6<\/td>\n            <td>40.0 &#8211; 44.0<\/td>\n            <td>1075<\/td>\n            <td>3200<\/td>\n            <td>115<\/td>\n            <td>20<\/td>\n          <\/tr>\n          <tr>\n            <td>3\u00d750 + Earth<\/td>\n            <td class=\"g\">6.6 \/ 6.6<\/td>\n            <td>45.0 &#8211; 50.0<\/td>\n            <td>1536<\/td>\n            <td>3900<\/td>\n            <td>145<\/td>\n            <td>20<\/td>\n          <\/tr>\n          <tr>\n            <td>3\u00d770 + Earth<\/td>\n            <td class=\"g\">6.6 \/ 6.6<\/td>\n            <td>50.0 &#8211; 55.0<\/td>\n            <td>2150<\/td>\n            <td>4700<\/td>\n            <td>180<\/td>\n            <td>20<\/td>\n          <\/tr>\n          <tr>\n            <td>3\u00d795 + Earth<\/td>\n            <td class=\"g\">6.6 \/ 6.6<\/td>\n            <td>55.0 &#8211; 60.0<\/td>\n            <td>2905<\/td>\n            <td>5800<\/td>\n            <td>215<\/td>\n            <td>20<\/td>\n          <\/tr>\n          <tr>\n            <td>3\u00d7120 + Earth<\/td>\n            <td class=\"g\">6.6 \/ 6.6<\/td>\n            <td>60.0 &#8211; 65.0<\/td>\n            <td>3660<\/td>\n            <td>7000<\/td>\n            <td>250<\/td>\n            <td>20<\/td>\n          <\/tr>\n          <tr>\n            <td>3\u00d7150 + Earth<\/td>\n            <td class=\"g\">6.6 \/ 6.6<\/td>\n            <td>65.0 &#8211; 70.0<\/td>\n            <td>4575<\/td>\n            <td>8300<\/td>\n            <td>290<\/td>\n            <td>20<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <p><span class=\"p\">* Ampacity at 30\u00b0C ambient, free air. Derating applies for reeling (bundled) installation.<\/span><\/p>\n\n    <h2 id=\"s6\">6. Mechanical Properties: Tensile Load Calculations and Stress Limits<\/h2>\n\n    <p>For mining equipment that continuously moves and stores cables on reels (draglines, bucket wheels, hoists), mechanical stress is as critical as electrical safety. The tensile load specification determines cable survival during dynamic reeling operations.<\/p>\n\n    <p><strong>Maximum Tensile Load Formula:<\/strong> The maximum safe pulling force on a cable is calculated as:<\/p>\n\n    <div class=\"eq\">F_max = n \u00d7 A \u00d7 \u03c3_allowable<\/div>\n\n    <p>Where: n = number of main conductors (typically 3 for power cables), A = cross-section per conductor (mm\u00b2), \u03c3_allowable = permissible tensile stress (typically 15 N\/mm\u00b2 for copper in mining cables). For a 3\u00d770 cable: F_max = 3 \u00d7 70 \u00d7 15 = 3150 N pulling force (approximately 320 kg-force). This limit must not be exceeded during installation or reeling operation to prevent conductor breakage.<\/p>\n\n    <p><strong>Dynamic Stress Limits:<\/strong> During acceleration and deceleration of reeling equipment, cables experience stress peaks above steady-state pulling force. The maximum tensile specification (typically 20 N\/mm\u00b2 for mining cables) accounts for these dynamic peaks. Reeling equipment must include load limiters or stress-limiting devices to prevent exceeding these limits.<\/p>\n\n    <h2 id=\"s7\">7. Dynamic Operation Parameters: Travel Speed, Torsional Stress, Bending Radius<\/h2>\n\n    <p>Mining cables are designed for continuous flexing and movement. The operating parameters that define safe dynamic service differ from static installation specifications.<\/p>\n\n    <p><strong>Maximum Travel Speed:<\/strong> Reeling cables are rated for travel speeds up to 120 m\/min during continuous reeling operation (cable winding\/unwinding on drum). Trailing cables suspended overhead may operate at 40 m\/min maximum depending on equipment design. Higher speeds create excessive cable fatigue and mechanical degradation.<\/p>\n\n    <p><strong>Torsional Stress Limit:<\/strong> The cable must not be twisted during operation. The maximum allowable torsional stress is typically \u00b125\u00b0\/m (meaning rotation of 25 degrees per meter of cable length). Exceeding this limit causes jacket tearing, insulation cracking, and conductor damage. Special anti-twist constructions (aramid fiber reinforcement) can increase this limit to \u00b140\u201350\u00b0\/m at additional cost.<\/p>\n\n    <p><strong>Bending Radius Specification:<\/strong> The minimum radius to which the cable can be bent without insulation damage is typically: 10\u00d7 outer diameter for free flexing operations, 15\u00d7 outer diameter for forced reeling through restricted drums. For a 55 mm diameter cable, minimum bending radius is 550\u2013825 mm. Reeling equipment must provide pulleys and guide rollers sized appropriately.<\/p>\n\n    <h2 id=\"s8\">8. Short-Circuit Behavior: Current Ratings and Thermal Limits<\/h2>\n\n    <p>Electrical system design requires knowledge of cable short-circuit current capacity to properly set protective device (circuit breaker) settings. The 6.6\/6.6kV cable&#8217;s short-circuit rating determines maximum fault current it can withstand without insulation damage.<\/p>\n\n    <p><strong>Short-Circuit Current Calculation:<\/strong> The estimated 1-second short-circuit current for EPR-insulated copper cables is:<\/p>\n\n    <div class=\"eq\">I_cc(1s) = (143 \u00d7 S) \/ \u221at<\/div>\n\n    <p>Where S = conductor cross-section (mm\u00b2), t = time (seconds). For a 3\u00d770 cable: I_cc = (143 \u00d7 70) \/ \u221a1 \u2248 10,010 A per phase. This current creates extreme thermal stress (conductor temperature rising to approximately 250\u00b0C) for 1 second before protective devices clear the fault.<\/p>\n\n    <p><strong>AC Test Voltage Specification:<\/strong> Factory testing of 6.6\/6.6kV cables includes dielectric strength test at 11 kV AC applied for 5 minutes without breakdown. This test verifies adequate insulation safety margin (11 kV test \u00f7 6.6 kV rated = 1.67\u00d7 safety margin).<\/p>\n\n    <p><strong>Thermal Limit at Short Circuit:<\/strong> The maximum conductor temperature during short circuit is 250\u00b0C for 5-second duration. Protective devices must clear faults within this time to prevent insulation damage and fire risk.<\/p>\n\n    <h2 id=\"s9\">9. Material Systems: EPR 3GI3 Insulation and 5GM5 Outer Sheath<\/h2>\n\n    <p>The 6.6\/6.6kV specification requires premium material systems that withstand sustained high-voltage stress and harsh mining environment exposure.<\/p>\n\n    <p><strong>EPR Type 3GI3 Insulation:<\/strong> The primary insulation is Ethylene Propylene Rubber Type 3GI3, a thermoset elastomer with specialized additive packages: (1) enhanced cross-linking for higher dielectric strength (18\u201320 kV\/mm), (2) antioxidants and thermal stabilizers for 90\u00b0C continuous operation, (3) ozone scavenging compounds for outdoor mine exposure, (4) partial discharge suppressants for voltage stress endurance. These enhancements increase material cost approximately 20\u201330% compared to standard EPR but are essential for 6.6kV voltage stress tolerance.<\/p>\n\n    <p><strong>Semi-Conductive Screening:<\/strong> Inner and outer semi-conductive rubber screens ensure uniform electrical field distribution within the insulation. For 6.6\/6.6kV cables, screen resistivity is tightly specified at 100\u20131000 ohm-centimeters, requiring precise material formulation and quality control.<\/p>\n\n    <p><strong>PCP Type 5GM5 Outer Sheath:<\/strong> The heavy-duty polychloroprene (neoprene) outer sheath provides: (1) abrasion resistance for contact with mining equipment and rough surfaces, (2) oil resistance (critical because mining equipment hydraulic systems leak constantly), (3) UV resistance for outdoor dragline and bucket wheel exposure, (4) flame retardancy (typically achieving V-0 or V-1 per UL94). Sheath thickness typically 2.5\u20133.5 mm, substantially heavier than standard industrial cables.<\/p>\n\n    <h2 id=\"s10\">10. Cable Testing and Commissioning: Verifying Uo\/U Specifications in Field<\/h2>\n\n    <p>When (N)TSKCGEW\u00d6U 6.6\/6.6kV cables are installed on mining equipment, site commissioning includes verification testing to confirm cable electrical integrity and Uo\/U compliance.<\/p>\n\n    <p><strong>Pre-Installation Testing:<\/strong> Before installation, cables should be tested for: (1) insulation resistance (megohm test) &#8211; minimum 100 megohms, (2) continuity of earth conductors &#8211; <1 ohm per phase, (3) dielectric strength at approximately 1.5\u00d7 rated voltage (approximately 10 kV applied for 1 minute without breakdown).<\/p>\n\n    <p><strong>Post-Installation Testing:<\/strong> After installation and termination, tests should include: (1) insulation resistance after thermal cycling, (2) dielectric strength at factory test voltage (11 kV for 5 minutes), (3) voltage drop measurement at rated current to verify conductor integrity, (4) earth continuity monitoring relay calibration (if ECM system present).<\/p>\n\n    <p><strong>Documentation Requirements:<\/strong> All test results must be documented with: cable identification, date of test, test equipment serial numbers, engineer signatures, and comparison to specification limits. This documentation serves as baseline reference for future condition monitoring.<\/p>\n\n    <h2 id=\"s11\">11. BOM Cost Analysis: Understanding Price Drivers for 6.6\/6.6kV Cables<\/h2>\n\n    <p>Procurement teams reviewing BOMs find that 6.6\/6.6kV cables cost 40\u201370% more than comparable 0.6\/1kV or even 3.8\/6.6kV alternatives. Understanding cost drivers helps justify price differences to management and optimize procurement strategies.<\/p>\n\n    <p><strong>Material Cost Premium:<\/strong> Enhanced EPR 3GI3 formulation adds approximately 15\u201320% to insulation material cost. Semi-conductive screening materials with tight resistivity tolerances add approximately 5\u201310%. Heavy-duty 5GM5 outer sheath (versus standard CPE or polyethylene) adds approximately 8\u201312%. Total material cost increase: approximately 28\u201342% compared to standard voltage ratings.<\/p>\n\n    <p><strong>Manufacturing Complexity:<\/strong> 6.6\/6.6kV cables require more sophisticated production equipment and quality control procedures. Tighter dimensional tolerances (thicker insulation must be precisely controlled within 0.1 mm), material mixing procedures for enhanced compounds, and comprehensive electrical testing add approximately 10\u201315% to manufacturing cost.<\/p>\n\n    <p><strong>Testing and Certification:<\/strong> Type testing (initial certification to VDE 0250-812 or AS\/NZS 1802 standards) requires expensive high-voltage equipment and laboratory time. Routine batch testing of 6.6\/6.6kV cables (dielectric strength at 11 kV) is more costly than standard voltage testing. These costs add approximately 5\u20138% to unit price.<\/p>\n\n    <p><strong>Supplier and Logistics:<\/strong> Qualified suppliers of 6.6\/6.6kV cables are fewer than standard voltage suppliers, reducing competition and potentially increasing prices. International shipping of heavier cables increases freight cost by approximately 15\u201325% compared to lighter standard-rated cables.<\/p>\n\n    <h2 id=\"s12\">12. Conclusion: Uo Rating as Safety and Reliability Foundation<\/h2>\n\n    <p>The 6.6\/6.6kV notation on Australian mining equipment BOMs is far more than a voltage specification\u2014it is a comprehensive safety and reliability framework designed for the specific electrical environment of IT earthing systems. The Uo = 6.6kV specification signals that the cable insulation is engineered to withstand sustained single-phase earth fault voltage stress that would destroy standard 3.8\/6.6kV cables within minutes.<\/p>\n\n    <p>For procurement engineers, BOM managers, and equipment designers, understanding the Uo\/U notation transforms cable selection from guesswork to informed engineering decision-making. The 6.6\/6.6kV specification enables safe, continuous mining operations in Australia&#8217;s harsh underground and surface environments, justifying its cost premium through extended cable life, reduced failure rates, and most importantly, personnel safety.<\/p>\n\n    <p>Feichun Special Cable manufactures (N)TSKCGEW\u00d6U 6.6\/6.6kV cables specifically engineered for Australian IT earthing systems. For mining operations and equipment manufacturers designing systems for Australian deployment, our technical team provides BOM support, cost analysis, and supply chain coordination to ensure proper cable specifications that meet AS\/NZS compliance while optimizing project economics.<\/p>\n\n  <\/div>\n\n  <section class=\"refs\">\n    <h2>References &#038; Sources<\/h2>\n    <ol class=\"rl\">\n      <li>AS\/NZS 1802:2012, &#8220;Rubber cables for underground mining applications,&#8221; Standards New Zealand and Standards Australia.<\/li>\n      <li>VDE 0250-812:2016, &#8220;Flexible cables \u2013 Part 812: Industrial applications,&#8221; Verband der Elektrotechnik Elektronik Informationstechnik.<\/li>\n      <li>IEC 60228:2004, &#8220;Conductors of insulated cables,&#8221; International Electrotechnical Commission.<\/li>\n      <li>VDE 0298-4:2013, &#8220;Electrical installations \u2013 Cable ampacity and derating factors,&#8221; Verband der Elektrotechnik Elektronik Informationstechnik.<\/li>\n      <li>AS\/NZS 5000.1:2018, &#8220;Power distribution cables \u2013 Part 1: General requirements,&#8221; Standards New Zealand and Standards Australia.<\/li>\n      <li>Feichun Special Cable Research &#038; Development Team, &#8220;TSKCGEWOU 6.6\/6.6kV Cable: Uo Rating Analysis and Field Performance,&#8221; Technical Report, 2024.<\/li>\n    <\/ol>\n  <\/section>\n\n  <div class=\"contact\">\n    <h3>Contact Anhui Feichun Special Cable Co., Ltd.<\/h3>\n    <div class=\"cg\">\n      <div class=\"ci\">\n        <span class=\"lb\">(N)TSKCGEW\u00d6U 6.6\/6.6kV Cable &#038; BOM Support<\/span>\n        <a href=\"mailto:tech@feichuncables.com\" rel=\"nofollow\">tech@feichuncables.com<\/a>\n      <\/div>\n      <div class=\"ci\">\n        <span class=\"lb\">Australian Mining &#038; Procurement<\/span>\n        <a href=\"mailto:mining@feichuncables.com\" rel=\"nofollow\">mining@feichuncables.com<\/a>\n      <\/div>\n      <div class=\"ci\">\n        <span class=\"lb\">Sales &#038; BOM Quotations<\/span>\n        <a href=\"mailto:sales@feichuncables.com\" rel=\"nofollow\">sales@feichuncables.com<\/a>\n      <\/div>\n      <div class=\"ci\">\n        <span class=\"lb\">WhatsApp \/ WeChat<\/span>\n        <a href=\"https:\/\/wa.me\/8613855123218\" rel=\"nofollow noopener\" target=\"_blank\">+86 138-5512-3218<\/a>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <footer class=\"ft\">\n    <p>&copy; 2026 Anhui Feichun Special Cable Co., Ltd. \u2014 All rights reserved.<\/p>\n    <p>Building A, Private Science &#038; Technology Park, Hefei Economic and Technological Development Zone, Anhui Province, China.<\/p>\n    <p><strong>SEO Keywords:<\/strong> phase-to-earth voltage, Uo rating 6.6kV, TSKCGEWOU cable, 6.6\/6.6kV medium voltage, Australian mining cable BOM, IT earthing system cable, AS\/NZS 1802 trailing cable, earth fault protection cable, cable voltage rating notation, reeling cable specifications, medium voltage cable parameters, EPR 3GI3 insulation, 5GM5 outer sheath, heavy duty reeling cable, dragline cable, bucket wheel cable, port machinery cable, cable short circuit rating, tensile strength cable, bending radius reeling, torsional stress cable, cable mechanical properties, Class 5 stranded copper, mining equipment power cable, industrial rubber cable, cable ampacity derating, cable traveling speed, cable test voltage, earth continuity monitoring cable, high voltage mining cable, cable outer diameter dimensions, cable weight specifications, copper conductor cable, cable cost specification, cable procurement BOM, cable technical datasheet, cable supplier Australia, reeling drum cable, cable design standard VDE, cable design standard AS\/NZS, cable engineering calculation, cable field installation, cable commissioning test, cable reliability mining, cable durability harsh environment, cable supply chain, cable logistics freight, cable inventory management.<\/p>\n  <\/footer>\n\n<\/article>\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"phase-to-earth voltage, Uo rating 6.6kV, TSKCGEWOU cable, 6.6\/6.6kV medium voltage, Australian mining cable BOM, IT earthing system cable, AS\/NZS 1802 trailing cable, earth fault protection cable, cable voltage rating notation, reeling cable specifications, medium voltage cable parameters, EPR 3GI3 insulation, 5GM5 outer sheath, heavy duty reeling cable, dragline cable, bucket wheel cable, port machinery cable, cable short circuit rating, tensile strength cable, bending radius reeling, torsional stress cable, cable mechanical properties, Class 5 stranded copper, mining equipment power cable, industrial rubber cable, cable ampacity derating, cable traveling speed, cable test voltage, earth continuity monitoring cable, high voltage mining cable, cable outer diameter dimensions, cable weight specifications, copper conductor cable, cable cost specification, cable procurement BOM, cable technical datasheet, cable supplier Australia, reeling drum cable, cable design standard VDE, cable design standard AS\/NZS, cable engineering calculation, cable field installation, cable commissioning test, cable reliability mining, cable durability harsh environment, cable supply chain, cable logistics freight, cable inventory management","protected":false},"author":1,"featured_media":8428,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[222,66],"tags":[6370,45903,27116,45902,45913,22960,5019,31457,45915,45919,45911,45909,45917,45921,45918,45920,41303,45906,45912,45914,1790,45907,6589,1891,45908,45910,45905,4122,13053,1001,1079,3349,3735,5642,32764,802,904,45729,45904,4366,45900,1032,4340,801,7287,5608,45901,45899],"class_list":["post-8427","post","type-post","status-publish","format-standard","has-post-thumbnail","category-as-nzs-1802-reeling-cables-for-underground-mining","category-common-problems-encountered-in-cable-applications","tag-5gm5-outer-sheath","tag-6-6-6-6kv-medium-voltage","tag-as-nzs-1802-trailing-cable","tag-australian-mining-cable-bom","tag-bending-radius-reeling","tag-bucket-wheel-cable","tag-cable-ampacity-derating","tag-cable-commissioning-test","tag-cable-cost-specification","tag-cable-design-standard-as-nzs","tag-cable-design-standard-vde","tag-cable-durability-harsh-environment","tag-cable-engineering-calculation-2","tag-cable-field-installation","tag-cable-inventory-management","tag-cable-logistics-freight","tag-cable-mechanical-properties","tag-cable-outer-diameter-dimensions","tag-cable-procurement-bom","tag-cable-reliability-mining","tag-cable-short-circuit-rating","tag-cable-supplier-australia","tag-cable-supply-chain","tag-cable-technical-datasheet","tag-cable-test-voltage","tag-cable-traveling-speed","tag-cable-voltage-rating-notation","tag-cable-weight-specifications","tag-class-5-stranded-copper","tag-copper-conductor-cable","tag-dragline-cable","tag-earth-continuity-monitoring-cable","tag-earth-fault-protection-cable","tag-epr-3gi3-insulation","tag-heavy-duty-reeling-cable-2","tag-high-voltage-mining-cable","tag-industrial-rubber-cable","tag-it-earthing-system-cable","tag-medium-voltage-cable-parameters","tag-mining-equipment-power-cable","tag-phase-to-earth-voltage-2","tag-port-machinery-cable","tag-reeling-cable-specifications","tag-reeling-drum-cable","tag-tensile-strength-cable","tag-torsional-stress-cable","tag-tskcgewou-cable-2","tag-uo-rating-6-6kv","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/8427","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=8427"}],"version-history":[{"count":2,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/8427\/revisions"}],"predecessor-version":[{"id":8431,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/8427\/revisions\/8431"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/8428"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=8427"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=8427"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=8427"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}