{"id":77200,"date":"2026-09-20T14:33:42","date_gmt":"2026-09-20T06:33:42","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=77200"},"modified":"2026-09-20T14:33:46","modified_gmt":"2026-09-20T06:33:46","slug":"opvc-jz-oz-yo-1-000-v-ul-csa-one-control-cable-for-iec-and-north-american-machines","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/opvc-jz-oz-yo-1-000-v-ul-csa-one-control-cable-for-iec-and-north-american-machines\/","title":{"rendered":"\u00d6PVC-JZ\/OZ-Y\u00f6 1 000 V UL\/CSA: one control cable for IEC and North American machines"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">An engineering guide to a dual-rated PVC control cable: UL 1 000 V and IEC 450\/750 V, cURus 80 \u00b0C, increased mineral-oil resistance, a 6 kV test voltage and bunched-cable fire performance to IEC 60332-3-24 Cat. C and CSA FT1.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"1a262a\" data-has-transparency=\"false\" style=\"--dominant-color: #1a262a;\" loading=\"lazy\" decoding=\"async\" width=\"905\" height=\"585\" sizes=\"auto, (max-width: 905px) 100vw, 905px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1939.avif\" alt=\"\" class=\"wp-image-77201 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1939.avif 905w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1939-300x194.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1939-767x496.avif 767w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1939-399x258.avif 399w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1939-800x517.avif 800w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1939-831x537.avif 831w\" \/><\/figure>\n\n\n\n<!DOCTYPE html><html lang=\"en-AU\"><head><meta charset=\"utf-8\"><meta name=\"viewport\" content=\"width=device-width,initial-scale=1\">\n<meta name=\"description\" content=\"FeiChun engineering guide: \u00d6PVC-JZ\/OZ-Y\u00f6 UL\/CSA oil-resistant PVC control cable, UL 1000 V \/ IEC 450\/750 V, cURus 80 \u00b0C, IEC 60332-3-24 Cat. C, CSA FT1, 6 kV test, full dimension tables.\">\n<meta name=\"keywords\" content=\"\u00d6PVC-JZ-Y\u00f6, UL 2570, CSA AWM, cURus 1000 V, oil resistant control cable, IEC 60332-3-24, CSA FT1, CEI 20-22, NBN C30-004 F2, FeiChun\">\n<title>\u00d6PVC-JZ\/OZ-Y\u00f6 1 000 V UL\/CSA oil-resistant control cable | FeiChun Cable<\/title><style>\n:root{--bg:#041018;--p:#0b202b;--p2:#123443;--ink:#f4f9fb;--muted:#b8ccd3;--line:#315b6f;--c:#55dff7;--g:#62df9c;--s:#e8c37b;--r:#ff777f;--v:#aa9bff}\n*{box-sizing:border-box}html{scroll-behavior:smooth}body{margin:0;background:var(--bg);color:var(--ink);font:16px Arial,Helvetica,sans-serif;line-height:1.68}.wrap{max-width:1840px;margin:auto;padding:0 28px}a{color:var(--c);text-decoration:none}a:hover{text-decoration:underline}.hero{padding:68px 0 64px;background:radial-gradient(circle at 10% 5%,rgba(85,223,247,.22),transparent 32%),radial-gradient(circle at 90% 8%,rgba(170,155,255,.16),transparent 32%),linear-gradient(135deg,#041018,#0b4056)}h1{font-size:46px;line-height:1.13;max-width:1250px;margin:18px 0 20px}h2{margin-top:52px;border-left:7px solid var(--c);padding-left:15px;line-height:1.2}h3{line-height:1.25}.lead{font-size:21px;max-width:1420px;color:#e7f4f7}.badges,.meta{display:flex;gap:10px;flex-wrap:wrap;margin-top:12px}.badges span,.meta span{background:#071821;border:1px solid var(--line);border-radius:22px;padding:8px 13px;font-weight:bold}.cards,.grid{display:grid;grid-template-columns:repeat(auto-fit,minmax(250px,1fr));gap:15px;margin:22px 0}.card,.box,.note,.warn,.source{background:var(--p);border:1px solid var(--line);border-radius:10px;padding:18px}.card{border-top:5px solid var(--c)}.value{font-size:30px;color:var(--c);font-weight:bold}.note{border-left:7px solid var(--c);margin:13px 0}.warn{border-left:7px solid var(--r);margin:13px 0}.toc{background:var(--p);border:1px solid var(--line);padding:20px;border-left:7px solid var(--c);margin-top:24px}.toc ol{columns:2;margin-top:8px}.scroll{overflow:auto;margin:18px 0}table{width:100%;border-collapse:collapse;background:#071821;min-width:1180px}caption{text-align:left;color:var(--s);font-weight:bold;padding:8px 0}th,td{border:1px solid var(--line);padding:8px 9px;vertical-align:top}th{background:var(--p2);color:#eaf6fa;position:sticky;top:0}td:first-child{color:var(--c);font-weight:bold}.formula{white-space:pre-line;background:#071821;border:1px solid var(--line);padding:17px;border-radius:8px;font-family:Consolas,monospace}.svg{border:1px solid var(--line);padding:10px;background:#071821;margin:22px 0;border-radius:8px}.svg svg{width:100%;height:auto;display:block}.svg-caption{color:var(--muted);font-size:14px;padding:8px 4px 2px}.contact{display:grid;grid-template-columns:1fr 1fr;gap:12px;margin-top:22px}.contact div{background:#071821;border:1px solid var(--line);padding:15px}.small{font-size:12px;color:#91a9b4}.tag{color:var(--s);font-weight:bold}.ok{color:var(--g);font-weight:bold}.danger{color:var(--r);font-weight:bold}code{color:var(--s)}footer{margin-top:50px;background:#02080c;padding:32px 0}@media(max-width:800px){h1{font-size:31px}.toc ol{columns:1}.contact{grid-template-columns:1fr}.wrap{padding:0 16px}.lead{font-size:18px}}\n@media print{body{background:#fff;color:#000}.hero,footer{background:#fff}}\n<\/style>\n<script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"TechArticle\",\"headline\":\"\u00d6PVC-JZ\/OZ-Y\u00f6 1 000 V UL\/CSA control cable: engineering guide\",\"inLanguage\":\"en-AU\",\"identifier\":\"FC-ART-JZUL-2026-C267\",\"author\":{\"@type\":\"Organization\",\"name\":\"Anhui Feichun Special Cable Co., Ltd.\"},\"dateModified\":\"2026-09-20\"}<\/script><\/head><body>\n<header class=\"hero\"><div class=\"wrap\"><div class=\"tag\">FEICHUN CABLE \u00b7 UL\/CSA OIL-RESISTANT CONTROL CABLE<\/div>\n<h1>\u00d6PVC-JZ\/OZ-Y\u00f6 1 000 V UL\/CSA: one control cable for IEC and North American machines<\/h1>\n<p class=\"lead\">An engineering guide to a dual-rated PVC control cable: UL 1 000 V and IEC 450\/750 V, cURus 80 \u00b0C, increased mineral-oil resistance, a 6 kV test voltage and bunched-cable fire performance to IEC 60332-3-24 Cat. C and CSA FT1.<\/p>\n<div class=\"badges\"><span>UL Style 2570<\/span><span>CSA AWM I A\/B II A\/B<\/span><span>cURus 80 \u00b0C \u00b7 1 000 V<\/span><span>IEC 450\/750 V<\/span><span>IEC 60332-3-24 Cat. C<\/span><span>CSA FT1<\/span><span>CEI 20-22 II<\/span><span>NBN C30-004 F2<\/span><span>6 kV test<\/span><span>RoHS \u00b7 CE<\/span><\/div>\n<div class=\"meta\"><span>Document FC-ART-JZUL-2026-C267<\/span><span>Updated: 20 September 2026<\/span><span>FeiChun Cable \/ \u98de\u7eaf\u7535\u7f06<\/span><\/div><\/div><\/header>\n<main class=\"wrap\">\n<div class=\"warn\"><strong>Engineer&#8217;s summary:<\/strong> the value of this cable is dual compliance. A machine builder can wire one cabinet for both IEC and UL\/CSA markets. Remember two limits: it is AWM (equipment wiring), not an NEC field-wiring tray cable, and it must not be flexed below \u22125 \u00b0C.<\/div>\n<nav class=\"toc\"><strong>Contents<\/strong><ol><li><a href=\"#designation\">Reading the designation<\/a><\/li><li><a href=\"#construction\">Construction<\/a><\/li><li><a href=\"#data\">Technical data<\/a><\/li><li><a href=\"#fire\">Fire performance<\/a><\/li><li><a href=\"#tables\">Full dimension tables<\/a><\/li><li><a href=\"#application\">Application envelope<\/a><\/li><li><a href=\"#compare\">Comparison<\/a><\/li><li><a href=\"#design\">Design calculations<\/a><\/li><li><a href=\"#quality\">Certification<\/a><\/li><li><a href=\"#faq\">FAQ<\/a><\/li><\/ol><\/nav>\n<section id=\"designation\"><h2>1. Reading the designation<\/h2><p><code>JZ<\/code> = with GNYE and numbered cores (\u2018G\u2019); <code>OZ<\/code> = without GNYE (\u2018x\u2019). <code>Y\u00f6<\/code> marks the oil-resistant PVC sheath (\u2018\u00f6\u2019 for \u00d6l, oil). <code>1 000 V UL\/CSA<\/code> refers to the UL Style 2570 \/ CSA AWM rating; the same cable is rated 450\/750 V under IEC.<\/p>\n<div class=\"cards\"><div class=\"card\"><div class=\"value\">101<\/div><p>Standard constructions, 2 \u00d7 0.5 to 4 G 70 mm\u00b2.<\/p><\/div><div class=\"card\"><div class=\"value\">6 kV<\/div><p>Test voltage.<\/p><\/div><div class=\"card\"><div class=\"value\">1 000 V<\/div><p>cURus at 80 \u00b0C.<\/p><\/div><div class=\"card\"><div class=\"value\">Cat. C<\/div><p>IEC 60332-3-24 bunched flame test.<\/p><\/div><\/div><\/section>\n<section id=\"construction\"><h2>2. Construction<\/h2><p>The construction mirrors the standard JZ\/OZ cable, but the sheath compound is the difference: it is formulated for increased mineral-oil resistance and for bunched-cable flame performance, and the insulation system is dimensioned for the UL 1 000 V rating and a 6 kV test.<\/p><div class=\"svg\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 1900 960\" role=\"img\" aria-label=\"JZ cross section\"><rect width=\"100%\" height=\"100%\" fill=\"#06131b\"><\/rect><defs><radialGradient id=\"cu\" cx=\"40%\" cy=\"35%\" r=\"70%\"><stop offset=\"0\" stop-color=\"#ffd2a1\"\/><stop offset=\".55\" stop-color=\"#c9793d\"\/><stop offset=\"1\" stop-color=\"#7a3f19\"\/><\/radialGradient><pattern id=\"h45\" width=\"12\" height=\"12\" patternUnits=\"userSpaceOnUse\" patternTransform=\"rotate(45)\"><rect width=\"12\" height=\"12\" fill=\"#6d7a80\"\/><line x1=\"0\" y1=\"0\" x2=\"0\" y2=\"12\" stroke=\"#a4b0b5\" stroke-width=\"3\"\/><\/pattern><pattern id=\"xh\" width=\"12\" height=\"12\" patternUnits=\"userSpaceOnUse\"><rect width=\"12\" height=\"12\" fill=\"#3a4d55\"\/><path d=\"M0 0L12 12M12 0L0 12\" stroke=\"#6f8c96\" stroke-width=\"1.4\"\/><\/pattern><marker id=\"ar\" markerWidth=\"12\" markerHeight=\"12\" refX=\"10\" refY=\"5\" orient=\"auto\"><path d=\"M0 0L12 5L0 10Z\" fill=\"#eaf6fa\"\/><\/marker><marker id=\"al\" markerWidth=\"12\" markerHeight=\"12\" refX=\"2\" refY=\"5\" orient=\"auto\"><path d=\"M12 0L0 5L12 10Z\" fill=\"#eaf6fa\"\/><\/marker><\/defs><text x=\"65\" y=\"70\" fill=\"#55dff7\" font-family=\"Arial\" font-size=\"40\" font-weight=\"700\">Cross-section \u00d6PVC-JZ-Y\u00f6 7 G \u00b7 numbered cores, oil-resistant FT1 sheath<\/text><text x=\"65\" y=\"108\" fill=\"#b8ccd3\" font-family=\"Arial\" font-size=\"19\">Engineering-drawing style \u00b7 functional, not to scale \u00b7 final dimensions per approved order drawing<\/text><circle cx=\"520\" cy=\"540\" r=\"340\" fill=\"url(#h45)\" stroke=\"#9aa6ab\" stroke-width=\"5\"\/><circle cx=\"520\" cy=\"540\" r=\"300\" fill=\"url(#xh)\"\/><circle cx=\"520\" cy=\"540\" r=\"96\" fill=\"#6bbf3a\" stroke=\"#0a0a0a\" stroke-width=\"3\"\/><path d=\"M424 540A96 96 0 0 1 616 540\" stroke=\"#f0d000\" stroke-width=\"28\" fill=\"none\"\/><circle cx=\"520\" cy=\"540\" r=\"58\" fill=\"url(#cu)\"\/><text x=\"520\" y=\"622\" text-anchor=\"middle\" font-family=\"Arial\" font-size=\"18\" font-weight=\"700\" fill=\"#ffffff\">GNYE<\/text><circle cx=\"520\" cy=\"344\" r=\"96\" fill=\"#141414\" stroke=\"#0a0a0a\" stroke-width=\"3\"\/><circle cx=\"520\" cy=\"344\" r=\"58\" fill=\"url(#cu)\"\/><text x=\"520\" y=\"426\" text-anchor=\"middle\" font-family=\"Arial\" font-size=\"22\" font-weight=\"700\" fill=\"#ffffff\">1<\/text><circle cx=\"690\" cy=\"442\" r=\"96\" fill=\"#141414\" stroke=\"#0a0a0a\" stroke-width=\"3\"\/><circle cx=\"690\" cy=\"442\" r=\"58\" fill=\"url(#cu)\"\/><text x=\"690\" y=\"524\" text-anchor=\"middle\" font-family=\"Arial\" font-size=\"22\" font-weight=\"700\" fill=\"#ffffff\">2<\/text><circle cx=\"690\" cy=\"638\" r=\"96\" fill=\"#141414\" stroke=\"#0a0a0a\" stroke-width=\"3\"\/><circle cx=\"690\" cy=\"638\" r=\"58\" fill=\"url(#cu)\"\/><text x=\"690\" y=\"720\" text-anchor=\"middle\" font-family=\"Arial\" font-size=\"22\" font-weight=\"700\" fill=\"#ffffff\">3<\/text><circle cx=\"520\" cy=\"736\" r=\"96\" fill=\"#141414\" stroke=\"#0a0a0a\" stroke-width=\"3\"\/><circle cx=\"520\" cy=\"736\" r=\"58\" fill=\"url(#cu)\"\/><text x=\"520\" y=\"818\" text-anchor=\"middle\" font-family=\"Arial\" font-size=\"22\" font-weight=\"700\" fill=\"#ffffff\">4<\/text><circle cx=\"350\" cy=\"638\" r=\"96\" fill=\"#141414\" stroke=\"#0a0a0a\" stroke-width=\"3\"\/><circle cx=\"350\" cy=\"638\" r=\"58\" fill=\"url(#cu)\"\/><text x=\"350\" y=\"720\" text-anchor=\"middle\" font-family=\"Arial\" font-size=\"22\" font-weight=\"700\" fill=\"#ffffff\">5<\/text><circle cx=\"350\" cy=\"442\" r=\"96\" fill=\"#141414\" stroke=\"#0a0a0a\" stroke-width=\"3\"\/><circle cx=\"350\" cy=\"442\" r=\"58\" fill=\"url(#cu)\"\/><text x=\"350\" y=\"524\" text-anchor=\"middle\" font-family=\"Arial\" font-size=\"22\" font-weight=\"700\" fill=\"#ffffff\">6<\/text><path d=\"M130 540H910M520 150V930\" stroke=\"#ff777f\" stroke-width=\"2\" stroke-dasharray=\"26 8 4 8\"\/><path d=\"M180 935H860\" stroke=\"#eaf6fa\" stroke-width=\"2.5\" marker-start=\"url(#al)\" marker-end=\"url(#ar)\"\/><path d=\"M180 540V950M860 540V950\" stroke=\"#eaf6fa\" stroke-width=\"1.4\" stroke-dasharray=\"6 6\"\/><text x=\"520\" y=\"923\" text-anchor=\"middle\" font-family=\"Arial\" font-size=\"23\" fill=\"#eaf6fa\">\u00d8 d = 5.0 \u2026 37.6 mm (see tables)<\/text><path d=\"M520 344L990 192H1030\" stroke=\"#d9edf0\" stroke-width=\"1.8\" fill=\"none\"\/><circle cx=\"1048\" cy=\"192\" r=\"17\" fill=\"#0c2630\" stroke=\"#55dff7\" stroke-width=\"2\"\/><text x=\"1048\" y=\"199\" text-anchor=\"middle\" font-family=\"Arial\" font-size=\"17\" font-weight=\"700\" fill=\"#55dff7\">1<\/text><text x=\"1078\" y=\"200\" font-family=\"Arial\" font-size=\"21\" fill=\"#eaf6fa\">Bare Cu strand, IEC 60228 class 5<\/text><path d=\"M690 442L990 272H1030\" stroke=\"#d9edf0\" stroke-width=\"1.8\" fill=\"none\"\/><circle cx=\"1048\" cy=\"272\" r=\"17\" fill=\"#0c2630\" stroke=\"#55dff7\" stroke-width=\"2\"\/><text x=\"1048\" y=\"279\" text-anchor=\"middle\" font-family=\"Arial\" font-size=\"17\" font-weight=\"700\" fill=\"#55dff7\">2<\/text><text x=\"1078\" y=\"280\" font-family=\"Arial\" font-size=\"21\" fill=\"#eaf6fa\">PVC core insulation, black<\/text><path d=\"M690 720L990 352H1030\" stroke=\"#d9edf0\" stroke-width=\"1.8\" fill=\"none\"\/><circle cx=\"1048\" cy=\"352\" r=\"17\" fill=\"#0c2630\" stroke=\"#55dff7\" stroke-width=\"2\"\/><text x=\"1048\" y=\"359\" text-anchor=\"middle\" font-family=\"Arial\" font-size=\"17\" font-weight=\"700\" fill=\"#55dff7\">3<\/text><text x=\"1078\" y=\"360\" font-family=\"Arial\" font-size=\"21\" fill=\"#eaf6fa\">White printed numerals (DIN VDE 0293)<\/text><path d=\"M520 540L990 432H1030\" stroke=\"#d9edf0\" stroke-width=\"1.8\" fill=\"none\"\/><circle cx=\"1048\" cy=\"432\" r=\"17\" fill=\"#0c2630\" stroke=\"#55dff7\" stroke-width=\"2\"\/><text x=\"1048\" y=\"439\" text-anchor=\"middle\" font-family=\"Arial\" font-size=\"17\" font-weight=\"700\" fill=\"#55dff7\">4<\/text><text x=\"1078\" y=\"440\" font-family=\"Arial\" font-size=\"21\" fill=\"#eaf6fa\">GNYE protective conductor (JZ only)<\/text><path d=\"M350 638L990 512H1030\" stroke=\"#d9edf0\" stroke-width=\"1.8\" fill=\"none\"\/><circle cx=\"1048\" cy=\"512\" r=\"17\" fill=\"#0c2630\" stroke=\"#55dff7\" stroke-width=\"2\"\/><text x=\"1048\" y=\"519\" text-anchor=\"middle\" font-family=\"Arial\" font-size=\"17\" font-weight=\"700\" fill=\"#55dff7\">5<\/text><text x=\"1078\" y=\"520\" font-family=\"Arial\" font-size=\"21\" fill=\"#eaf6fa\">Cores stranded in layers<\/text><path d=\"M830 680L990 592H1030\" stroke=\"#d9edf0\" stroke-width=\"1.8\" fill=\"none\"\/><circle cx=\"1048\" cy=\"592\" r=\"17\" fill=\"#0c2630\" stroke=\"#55dff7\" stroke-width=\"2\"\/><text x=\"1048\" y=\"599\" text-anchor=\"middle\" font-family=\"Arial\" font-size=\"17\" font-weight=\"700\" fill=\"#55dff7\">6<\/text><text x=\"1078\" y=\"600\" font-family=\"Arial\" font-size=\"21\" fill=\"#eaf6fa\">Grey PVC sheath RAL 7001, mineral-oil resistant, flame-retardant<\/text><rect x=\"990\" y=\"760\" width=\"840\" height=\"120\" fill=\"#071821\" stroke=\"#315b6f\"\/><path d=\"M990 800H1830M1390 760V880M1620 760V880\" stroke=\"#315b6f\"\/><g font-family=\"Arial\" font-size=\"17\" fill=\"#b8ccd3\"><text x=\"1005\" y=\"788\">Document<\/text><text x=\"1405\" y=\"788\">Revision<\/text><text x=\"1635\" y=\"788\">Projection<\/text><text x=\"1005\" y=\"845\" fill=\"#eaf6fa\" font-size=\"21\" font-weight=\"700\">FC-ART-JZUL-2026-C267<\/text><text x=\"1405\" y=\"845\" fill=\"#eaf6fa\" font-size=\"21\">A \u00b7 2026-09<\/text><text x=\"1635\" y=\"845\" fill=\"#eaf6fa\" font-size=\"21\">1st angle<\/text><\/g><\/svg><div class=\"svg-caption\">Figure 1: Construction of the 7 G version; callouts match the Pos. column of the materials table.<\/div><\/div>\n<div class=\"scroll\"><table style=\"min-width:1180px\"><caption>Materials table (Pos. = callout numbers in Figure 1)<\/caption><thead><tr><th>Pos.<\/th><th>Element<\/th><th>Material \/ form<\/th><th>Engineering function<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>Conductor<\/td><td>Bare Cu, fine-wire, IEC 60228 cl. 5<\/td><td>Flexibility for installation and free movement<\/td><\/tr><tr><td>2<\/td><td>Core insulation<\/td><td>PVC, black (coloured to DIN VDE 0293-308 on request)<\/td><td>UL 80 \u00b0C \/ 1 000 V rating; 6 kV test<\/td><\/tr><tr><td>3<\/td><td>Core marking<\/td><td>White numerals per DIN VDE 0293<\/td><td>Unambiguous identification in multicore circuits<\/td><\/tr><tr><td>4<\/td><td>Protective conductor<\/td><td>GNYE core in JZ (\u2018G\u2019) versions<\/td><td>OZ (\u2018x\u2019) versions have none<\/td><\/tr><tr><td>5<\/td><td>Core assembly<\/td><td>Stranded in layers<\/td><td>Round geometry for UL\/CSA fittings and glands<\/td><\/tr><tr><td>6<\/td><td>Outer sheath<\/td><td>Oil-resistant PVC \u2018Y\u00f6\u2019, grey RAL 7001<\/td><td>Increased mineral-oil resistance; IEC 60332-3-24 Cat. C, CSA FT1<\/td><\/tr><\/tbody><\/table><\/div><\/section>\n<section id=\"data\"><h2>3. Technical data<\/h2><div class=\"scroll\"><table style=\"min-width:1180px\"><caption>Technical data (complete)<\/caption><thead><tr><th>Parameter<\/th><th>Value<\/th><th>Engineering note<\/th><\/tr><\/thead><tbody><tr><td>Conductor material<\/td><td>Bare copper strand<\/td><td><\/td><\/tr><tr><td>Conductor class<\/td><td>IEC 60228 class 5<\/td><td><\/td><\/tr><tr><td>Core insulation<\/td><td>PVC<\/td><td><\/td><\/tr><tr><td>Core identification<\/td><td>Acc. to DIN VDE 0293: black cores with white numerals, with or without GNYE<\/td><td>Also available with coloured cores acc. to DIN VDE 0293-308, with or without GN\/YE<\/td><\/tr><tr><td>Stranding<\/td><td>Cores stranded in layers<\/td><td><\/td><\/tr><tr><td>Outer sheath<\/td><td>PVC (oil-resistant)<\/td><td><\/td><\/tr><tr><td>Sheath colour<\/td><td>Grey, RAL 7001<\/td><td><\/td><\/tr><tr><td>Rated voltage<\/td><td>UL: 1 000 V; IEC: 450\/750 V<\/td><td>One cable, two rating systems<\/td><\/tr><tr><td>Test voltage<\/td><td>6 kV<\/td><td><\/td><\/tr><tr><td>Conductor resistance<\/td><td>Acc. to IEC 60228 class 5<\/td><td><\/td><\/tr><tr><td>Insulation resistance<\/td><td>Min. 20 M\u03a9 \u00d7 km<\/td><td><\/td><\/tr><tr><td>Current carrying capacity<\/td><td>Acc. to DIN VDE<\/td><td>For NEC installations apply the NEC\/UL ampacity basis<\/td><\/tr><tr><td>Min. bending radius fixed<\/td><td>4 \u00d7 d<\/td><td><\/td><\/tr><tr><td>Min. bending radius moved<\/td><td>15 \u00d7 d<\/td><td><\/td><\/tr><tr><td>Operating temp. fixed<\/td><td>\u221240 \u00b0C \/ +80 \u00b0C<\/td><td><\/td><\/tr><tr><td>Operating temp. moved<\/td><td>\u22125 \u00b0C \/ +80 \u00b0C<\/td><td>Note: higher lower limit than standard PVC types (\u221215 \u00b0C)<\/td><\/tr><tr><td>Burning behaviour<\/td><td>Self-extinguishing acc. to IEC 60332-1; reduced fire propagation and flame-retardant acc. to IEC 60332-3-24 (Cat. C), CEI 20-22 II (00), NBN C30-004 Cat. F2, CSA FT1<\/td><td>Bunched-cable fire performance, not only single-cable<\/td><\/tr><tr><td>Chemical resistance<\/td><td>Increased oil resistance; largely resistant to acids and bases<\/td><td><\/td><\/tr><tr><td>Standard<\/td><td>UL Style 2570 \/ CSA AWM I A\/B II A\/B<\/td><td><\/td><\/tr><tr><td>Approvals<\/td><td>cURus: 80 \u00b0C \u2013 1 000 V<\/td><td><\/td><\/tr><tr><td>Compliance<\/td><td>RoHS; 2014\/35\/EU Low Voltage Directive (CE); LABS-\/silicone-free during production<\/td><td><\/td><\/tr><tr><td>Installation remark<\/td><td>Where mechanical damage risk exists, protect with tubes, channels, etc.<\/td><td><\/td><\/tr><\/tbody><\/table><\/div><\/section>\n<section id=\"fire\"><h2>4. Fire performance: what each test proves<\/h2><div class=\"scroll\"><table style=\"min-width:1180px\"><caption>Flame tests met by the cable<\/caption><thead><tr><th>Test<\/th><th>Configuration<\/th><th>What it demonstrates<\/th><\/tr><\/thead><tbody><tr><td>IEC 60332-1<\/td><td>Single vertical cable, 1 kW burner<\/td><td>Self-extinguishing; flame does not travel along a single cable<\/td><\/tr><tr><td>IEC 60332-3-24 Cat. C<\/td><td>Bunched vertical cables, 1.5 l\/m non-metallic volume, 20 min<\/td><td>Reduced fire propagation in cable trays and risers<\/td><\/tr><tr><td>CEI 20-22 II<\/td><td>Italian bunched-cable test<\/td><td>Acceptance in Italian installations<\/td><\/tr><tr><td>NBN C30-004 Cat. F2<\/td><td>Belgian flame-propagation category<\/td><td>Acceptance in Belgian installations<\/td><\/tr><tr><td>CSA FT1<\/td><td>Vertical flame test, Canada<\/td><td>Canadian flame rating for the AWM listing<\/td><\/tr><\/tbody><\/table><\/div>\n<div class=\"note\">IEC 60332-3-24 Cat. C is a propagation test, not fire resistance: the cable is not designed to keep circuits working during a fire. Where circuit integrity is required, specify a fire-resistant cable.<\/div><\/section>\n<section id=\"tables\"><h2>5. Full dimension and weight tables<\/h2><p>All 101 constructions are listed, grouped by cross-section. Outer diameters are supplier values; bending radii are calculated from them.<\/p>\n<div class=\"warn\"><strong>Source data to verify before publication:<\/strong> two rows appear inconsistent in the supplied table and are shown as received \u2014 26 G 1.5 (Cu index 619.0 = weight 619.0 kg\/km; expected Cu index \u2248 374 kg\/km) and 3 G 16 (weight 363.0 kg\/km is below its Cu index 460.8 kg\/km).<\/div><div class=\"scroll\"><table style=\"min-width:1400px\"><caption>Cross-section 0.5 mm\u00b2 \u00b7 UL 1 000 V \/ IEC 450\/750 V \u00b7 15 constructions<\/caption><thead><tr><th>Dimension n \u00d7 mm\u00b2<\/th><th>Version<\/th><th>Reference item no.<\/th><th>Outer \u00d8 (supp.) mm<\/th><th>Cu index kg\/km<\/th><th>Weight kg\/km<\/th><th>Min. bend radius fixed (4 \u00d7 d) mm<\/th><th>Min. bend radius moved (15 \u00d7 d) mm<\/th><\/tr><\/thead><tbody><tr><td>2 x 0.5<\/td><td>OZ (without GNYE)<\/td><td>1001171<\/td><td>5.0<\/td><td>9.6<\/td><td>34.0<\/td><td>20<\/td><td>75<\/td><\/tr><tr><td>3 G 0.5<\/td><td>JZ (with GNYE)<\/td><td>1001172<\/td><td>5.3<\/td><td>14.4<\/td><td>41.0<\/td><td>21<\/td><td>80<\/td><\/tr><tr><td>3 x 0.5<\/td><td>OZ (without GNYE)<\/td><td>1001173<\/td><td>5.3<\/td><td>14.4<\/td><td>41.0<\/td><td>21<\/td><td>80<\/td><\/tr><tr><td>4 G 0.5<\/td><td>JZ (with GNYE)<\/td><td>1001174<\/td><td>5.7<\/td><td>19.2<\/td><td>49.0<\/td><td>23<\/td><td>86<\/td><\/tr><tr><td>4 x 0.5<\/td><td>OZ (without GNYE)<\/td><td>1001176<\/td><td>5.7<\/td><td>19.2<\/td><td>49.0<\/td><td>23<\/td><td>86<\/td><\/tr><tr><td>5 G 0.5<\/td><td>JZ (with GNYE)<\/td><td>1001177<\/td><td>6.3<\/td><td>24.0<\/td><td>64.0<\/td><td>25<\/td><td>94<\/td><\/tr><tr><td>5 x 0.5<\/td><td>OZ (without GNYE)<\/td><td>1001181<\/td><td>6.3<\/td><td>24.0<\/td><td>64.0<\/td><td>25<\/td><td>94<\/td><\/tr><tr><td>7 G 0.5<\/td><td>JZ (with GNYE)<\/td><td>1001188<\/td><td>6.8<\/td><td>33.6<\/td><td>78.0<\/td><td>27<\/td><td>102<\/td><\/tr><tr><td>7 x 0.5<\/td><td>OZ (without GNYE)<\/td><td>1001200<\/td><td>6.8<\/td><td>33.6<\/td><td>78.0<\/td><td>27<\/td><td>102<\/td><\/tr><tr><td>8 G 0.5<\/td><td>JZ (with GNYE)<\/td><td>1001201<\/td><td>8.1<\/td><td>38.4<\/td><td>105.0<\/td><td>32<\/td><td>122<\/td><\/tr><tr><td>9 G 0.5<\/td><td>JZ (with GNYE)<\/td><td>1001202<\/td><td>8.4<\/td><td>43.2<\/td><td>116.0<\/td><td>34<\/td><td>126<\/td><\/tr><tr><td>10 G 0.5<\/td><td>JZ (with GNYE)<\/td><td>1001203<\/td><td>8.4<\/td><td>48.0<\/td><td>121.0<\/td><td>34<\/td><td>126<\/td><\/tr><tr><td>12 G 0.5<\/td><td>JZ (with GNYE)<\/td><td>1001206<\/td><td>8.7<\/td><td>57.6<\/td><td>139.0<\/td><td>35<\/td><td>130<\/td><\/tr><tr><td>18 G 0.5<\/td><td>JZ (with GNYE)<\/td><td>1001210<\/td><td>10.4<\/td><td>86.4<\/td><td>199.0<\/td><td>42<\/td><td>156<\/td><\/tr><tr><td>25 G 0.5<\/td><td>JZ (with GNYE)<\/td><td>1001213<\/td><td>12.1<\/td><td>120.0<\/td><td>270.0<\/td><td>48<\/td><td>182<\/td><\/tr><\/tbody><\/table><\/div><div class=\"scroll\"><table style=\"min-width:1400px\"><caption>Cross-section 0.75 mm\u00b2 \u00b7 UL 1 000 V \/ IEC 450\/750 V \u00b7 10 constructions<\/caption><thead><tr><th>Dimension n \u00d7 mm\u00b2<\/th><th>Version<\/th><th>Reference item no.<\/th><th>Outer \u00d8 (supp.) mm<\/th><th>Cu index kg\/km<\/th><th>Weight kg\/km<\/th><th>Min. bend radius fixed (4 \u00d7 d) mm<\/th><th>Min. bend radius moved (15 \u00d7 d) mm<\/th><\/tr><\/thead><tbody><tr><td>2 x 0.75<\/td><td>OZ (without GNYE)<\/td><td>1001234<\/td><td>5.4<\/td><td>14.4<\/td><td>42.0<\/td><td>22<\/td><td>81<\/td><\/tr><tr><td>3 G 0.75<\/td><td>JZ (with GNYE)<\/td><td>1001237<\/td><td>5.7<\/td><td>21.6<\/td><td>51.0<\/td><td>23<\/td><td>86<\/td><\/tr><tr><td>4 G 0.75<\/td><td>JZ (with GNYE)<\/td><td>1001238<\/td><td>6.2<\/td><td>28.8<\/td><td>66.0<\/td><td>25<\/td><td>93<\/td><\/tr><tr><td>5 G 0.75<\/td><td>JZ (with GNYE)<\/td><td>1001239<\/td><td>6.8<\/td><td>36.0<\/td><td>80.0<\/td><td>27<\/td><td>102<\/td><\/tr><tr><td>7 G 0.75<\/td><td>JZ (with GNYE)<\/td><td>1001241<\/td><td>7.4<\/td><td>50.4<\/td><td>104.0<\/td><td>30<\/td><td>111<\/td><\/tr><tr><td>9 G 0.75<\/td><td>JZ (with GNYE)<\/td><td>1001243<\/td><td>9.2<\/td><td>64.8<\/td><td>150.0<\/td><td>37<\/td><td>138<\/td><\/tr><tr><td>12 G 0.75<\/td><td>JZ (with GNYE)<\/td><td>1001245<\/td><td>9.5<\/td><td>86.4<\/td><td>177.0<\/td><td>38<\/td><td>142<\/td><\/tr><tr><td>18 G 0.75<\/td><td>JZ (with GNYE)<\/td><td>1001248<\/td><td>11.4<\/td><td>129.6<\/td><td>262.0<\/td><td>46<\/td><td>171<\/td><\/tr><tr><td>25 G 0.75<\/td><td>JZ (with GNYE)<\/td><td>1001254<\/td><td>13.3<\/td><td>180.0<\/td><td>356.0<\/td><td>53<\/td><td>200<\/td><\/tr><tr><td>34 G 0.75<\/td><td>JZ (with GNYE)<\/td><td>1001255<\/td><td>15.7<\/td><td>244.8<\/td><td>495.0<\/td><td>63<\/td><td>236<\/td><\/tr><\/tbody><\/table><\/div><div class=\"scroll\"><table style=\"min-width:1400px\"><caption>Cross-section 1 mm\u00b2 \u00b7 UL 1 000 V \/ IEC 450\/750 V \u00b7 22 constructions<\/caption><thead><tr><th>Dimension n \u00d7 mm\u00b2<\/th><th>Version<\/th><th>Reference item no.<\/th><th>Outer \u00d8 (supp.) mm<\/th><th>Cu index kg\/km<\/th><th>Weight kg\/km<\/th><th>Min. bend radius fixed (4 \u00d7 d) mm<\/th><th>Min. bend radius moved (15 \u00d7 d) mm<\/th><\/tr><\/thead><tbody><tr><td>2 x 1<\/td><td>OZ (without GNYE)<\/td><td>1001264<\/td><td>5.7<\/td><td>19.2<\/td><td>49.0<\/td><td>23<\/td><td>86<\/td><\/tr><tr><td>3 G 1<\/td><td>JZ (with GNYE)<\/td><td>1001266<\/td><td>6.1<\/td><td>28.8<\/td><td>64.0<\/td><td>24<\/td><td>92<\/td><\/tr><tr><td>4 G 1<\/td><td>JZ (with GNYE)<\/td><td>1001270<\/td><td>6.6<\/td><td>38.4<\/td><td>79.0<\/td><td>26<\/td><td>99<\/td><\/tr><tr><td>4 x 1<\/td><td>OZ (without GNYE)<\/td><td>1002579<\/td><td>6.6<\/td><td>38.4<\/td><td>79.0<\/td><td>26<\/td><td>99<\/td><\/tr><tr><td>5 G 1<\/td><td>JZ (with GNYE)<\/td><td>1001271<\/td><td>7.2<\/td><td>48.0<\/td><td>95.0<\/td><td>29<\/td><td>108<\/td><\/tr><tr><td>6 G 1<\/td><td>JZ (with GNYE)<\/td><td>1001273<\/td><td>7.8<\/td><td>57.6<\/td><td>116.0<\/td><td>31<\/td><td>117<\/td><\/tr><tr><td>7 G 1<\/td><td>JZ (with GNYE)<\/td><td>1001276<\/td><td>7.8<\/td><td>67.2<\/td><td>123.0<\/td><td>31<\/td><td>117<\/td><\/tr><tr><td>8 G 1<\/td><td>JZ (with GNYE)<\/td><td>1001279<\/td><td>9.5<\/td><td>76.8<\/td><td>161.0<\/td><td>38<\/td><td>142<\/td><\/tr><tr><td>9 G 1<\/td><td>JZ (with GNYE)<\/td><td>1001280<\/td><td>10.0<\/td><td>86.4<\/td><td>179.0<\/td><td>40<\/td><td>150<\/td><\/tr><tr><td>10 G 1<\/td><td>JZ (with GNYE)<\/td><td>1001282<\/td><td>10.0<\/td><td>96.0<\/td><td>196.0<\/td><td>40<\/td><td>150<\/td><\/tr><tr><td>12 G 1<\/td><td>JZ (with GNYE)<\/td><td>1001283<\/td><td>10.3<\/td><td>115.2<\/td><td>217.0<\/td><td>41<\/td><td>154<\/td><\/tr><tr><td>14 G 1<\/td><td>JZ (with GNYE)<\/td><td>1001284<\/td><td>11.2<\/td><td>134.4<\/td><td>244.0<\/td><td>45<\/td><td>168<\/td><\/tr><tr><td>16 G 1<\/td><td>JZ (with GNYE)<\/td><td>1001285<\/td><td>11.4<\/td><td>153.6<\/td><td>279.0<\/td><td>46<\/td><td>171<\/td><\/tr><tr><td>18 G 1<\/td><td>JZ (with GNYE)<\/td><td>1001287<\/td><td>12.3<\/td><td>172.8<\/td><td>313.0<\/td><td>49<\/td><td>184<\/td><\/tr><tr><td>19 G 1<\/td><td>JZ (with GNYE)<\/td><td>1001288<\/td><td>12.7<\/td><td>182.4<\/td><td>320.0<\/td><td>51<\/td><td>190<\/td><\/tr><tr><td>20 G 1<\/td><td>JZ (with GNYE)<\/td><td>1002154<\/td><td>13.0<\/td><td>192.0<\/td><td>355.0<\/td><td>52<\/td><td>195<\/td><\/tr><tr><td>25 G 1<\/td><td>JZ (with GNYE)<\/td><td>1001294<\/td><td>14.3<\/td><td>240.0<\/td><td>432.0<\/td><td>57<\/td><td>214<\/td><\/tr><tr><td>26 G 1<\/td><td>JZ (with GNYE)<\/td><td>1002157<\/td><td>15.3<\/td><td>249.6<\/td><td>454.0<\/td><td>61<\/td><td>230<\/td><\/tr><tr><td>34 G 1<\/td><td>JZ (with GNYE)<\/td><td>1001299<\/td><td>16.9<\/td><td>326.4<\/td><td>602.0<\/td><td>68<\/td><td>253<\/td><\/tr><tr><td>37 G 1<\/td><td>JZ (with GNYE)<\/td><td>1001301<\/td><td>16.9<\/td><td>355.2<\/td><td>622.0<\/td><td>68<\/td><td>253<\/td><\/tr><tr><td>42 G 1<\/td><td>JZ (with GNYE)<\/td><td>1001307<\/td><td>19.2<\/td><td>403.2<\/td><td>721.0<\/td><td>77<\/td><td>288<\/td><\/tr><tr><td>50 G 1<\/td><td>JZ (with GNYE)<\/td><td>1001308<\/td><td>19.9<\/td><td>480.0<\/td><td>856.0<\/td><td>80<\/td><td>298<\/td><\/tr><\/tbody><\/table><\/div><div class=\"scroll\"><table style=\"min-width:1400px\"><caption>Cross-section 1.5 mm\u00b2 \u00b7 UL 1 000 V \/ IEC 450\/750 V \u00b7 17 constructions<\/caption><thead><tr><th>Dimension n \u00d7 mm\u00b2<\/th><th>Version<\/th><th>Reference item no.<\/th><th>Outer \u00d8 (supp.) mm<\/th><th>Cu index kg\/km<\/th><th>Weight kg\/km<\/th><th>Min. bend radius fixed (4 \u00d7 d) mm<\/th><th>Min. bend radius moved (15 \u00d7 d) mm<\/th><\/tr><\/thead><tbody><tr><td>2 x 1.5<\/td><td>OZ (without GNYE)<\/td><td>1001323<\/td><td>6.3<\/td><td>28.8<\/td><td>68.0<\/td><td>25<\/td><td>94<\/td><\/tr><tr><td>3 G 1.5<\/td><td>JZ (with GNYE)<\/td><td>1001324<\/td><td>6.7<\/td><td>43.2<\/td><td>84.0<\/td><td>27<\/td><td>100<\/td><\/tr><tr><td>4 G 1.5<\/td><td>JZ (with GNYE)<\/td><td>1001330<\/td><td>7.3<\/td><td>57.6<\/td><td>108.0<\/td><td>29<\/td><td>110<\/td><\/tr><tr><td>5 G 1.5<\/td><td>JZ (with GNYE)<\/td><td>1001333<\/td><td>8.0<\/td><td>72.0<\/td><td>131.0<\/td><td>32<\/td><td>120<\/td><\/tr><tr><td>6 G 1.5<\/td><td>JZ (with GNYE)<\/td><td>1001334<\/td><td>8.7<\/td><td>86.4<\/td><td>160.0<\/td><td>35<\/td><td>130<\/td><\/tr><tr><td>7 G 1.5<\/td><td>JZ (with GNYE)<\/td><td>1001344<\/td><td>8.7<\/td><td>100.8<\/td><td>171.0<\/td><td>35<\/td><td>130<\/td><\/tr><tr><td>9 G 1.5<\/td><td>JZ (with GNYE)<\/td><td>1001346<\/td><td>11.2<\/td><td>129.6<\/td><td>245.0<\/td><td>45<\/td><td>168<\/td><\/tr><tr><td>10 G 1.5<\/td><td>JZ (with GNYE)<\/td><td>1001347<\/td><td>11.2<\/td><td>144.0<\/td><td>269.0<\/td><td>45<\/td><td>168<\/td><\/tr><tr><td>12 G 1.5<\/td><td>JZ (with GNYE)<\/td><td>1001348<\/td><td>11.5<\/td><td>172.8<\/td><td>298.0<\/td><td>46<\/td><td>172<\/td><\/tr><tr><td>18 G 1.5<\/td><td>JZ (with GNYE)<\/td><td>1001354<\/td><td>14.4<\/td><td>259.2<\/td><td>433.0<\/td><td>58<\/td><td>216<\/td><\/tr><tr><td>19 G 1.5<\/td><td>JZ (with GNYE)<\/td><td>1001356<\/td><td>14.4<\/td><td>273.6<\/td><td>443.0<\/td><td>58<\/td><td>216<\/td><\/tr><tr><td>25 G 1.5<\/td><td>JZ (with GNYE)<\/td><td>1001360<\/td><td>16.0<\/td><td>360.0<\/td><td>594.0<\/td><td>64<\/td><td>240<\/td><\/tr><tr><td>26 G 1.5<\/td><td>JZ (with GNYE)<\/td><td>1002158<\/td><td>17.2<\/td><td>619.0<\/td><td>619.0<\/td><td>69<\/td><td>258<\/td><\/tr><tr><td>34 G 1.5<\/td><td>JZ (with GNYE)<\/td><td>1001363<\/td><td>19.2<\/td><td>489.6<\/td><td>827.0<\/td><td>77<\/td><td>288<\/td><\/tr><tr><td>37 G 1.5<\/td><td>JZ (with GNYE)<\/td><td>1001364<\/td><td>19.2<\/td><td>532.8<\/td><td>858.0<\/td><td>77<\/td><td>288<\/td><\/tr><tr><td>42 G 1.5<\/td><td>JZ (with GNYE)<\/td><td>1001365<\/td><td>21.6<\/td><td>604.8<\/td><td>989.0<\/td><td>86<\/td><td>324<\/td><\/tr><tr><td>50 G 1.5<\/td><td>JZ (with GNYE)<\/td><td>1001366<\/td><td>23.0<\/td><td>720.0<\/td><td>1,190.0<\/td><td>92<\/td><td>345<\/td><\/tr><\/tbody><\/table><\/div><div class=\"scroll\"><table style=\"min-width:1400px\"><caption>Cross-section 2.5 mm\u00b2 \u00b7 UL 1 000 V \/ IEC 450\/750 V \u00b7 13 constructions<\/caption><thead><tr><th>Dimension n \u00d7 mm\u00b2<\/th><th>Version<\/th><th>Reference item no.<\/th><th>Outer \u00d8 (supp.) mm<\/th><th>Cu index kg\/km<\/th><th>Weight kg\/km<\/th><th>Min. bend radius fixed (4 \u00d7 d) mm<\/th><th>Min. bend radius moved (15 \u00d7 d) mm<\/th><\/tr><\/thead><tbody><tr><td>2 x 2.5<\/td><td>OZ (without GNYE)<\/td><td>1001386<\/td><td>7.5<\/td><td>48.0<\/td><td>105.0<\/td><td>30<\/td><td>112<\/td><\/tr><tr><td>3 G 2.5<\/td><td>JZ (with GNYE)<\/td><td>1001389<\/td><td>8.0<\/td><td>72.0<\/td><td>132.0<\/td><td>32<\/td><td>120<\/td><\/tr><tr><td>4 G 2.5<\/td><td>JZ (with GNYE)<\/td><td>1001392<\/td><td>8.7<\/td><td>96.0<\/td><td>167.0<\/td><td>35<\/td><td>130<\/td><\/tr><tr><td>5 G 2.5<\/td><td>JZ (with GNYE)<\/td><td>1001395<\/td><td>9.6<\/td><td>120.0<\/td><td>205.0<\/td><td>38<\/td><td>144<\/td><\/tr><tr><td>7 G 2.5<\/td><td>JZ (with GNYE)<\/td><td>1001397<\/td><td>10.7<\/td><td>168.0<\/td><td>268.0<\/td><td>43<\/td><td>160<\/td><\/tr><tr><td>8 G 2.5<\/td><td>JZ (with GNYE)<\/td><td>1001398<\/td><td>13.3<\/td><td>192.0<\/td><td>348.0<\/td><td>53<\/td><td>200<\/td><\/tr><tr><td>10 G 2.5<\/td><td>JZ (with GNYE)<\/td><td>1001399<\/td><td>14.3<\/td><td>240.0<\/td><td>416.0<\/td><td>57<\/td><td>214<\/td><\/tr><tr><td>12 G 2.5<\/td><td>JZ (with GNYE)<\/td><td>1001400<\/td><td>14.4<\/td><td>288.0<\/td><td>475.0<\/td><td>58<\/td><td>216<\/td><\/tr><tr><td>14 G 2.5<\/td><td>JZ (with GNYE)<\/td><td>1001401<\/td><td>15.7<\/td><td>336.0<\/td><td>535.0<\/td><td>63<\/td><td>236<\/td><\/tr><tr><td>16 G 2.5<\/td><td>JZ (with GNYE)<\/td><td>1001402<\/td><td>16.7<\/td><td>384.0<\/td><td>608.0<\/td><td>67<\/td><td>250<\/td><\/tr><tr><td>18 G 2.5<\/td><td>JZ (with GNYE)<\/td><td>1001406<\/td><td>17.1<\/td><td>432.0<\/td><td>692.0<\/td><td>68<\/td><td>256<\/td><\/tr><tr><td>25 G 2.5<\/td><td>JZ (with GNYE)<\/td><td>1001407<\/td><td>19.9<\/td><td>600.0<\/td><td>952.0<\/td><td>80<\/td><td>298<\/td><\/tr><tr><td>34 G 2.5<\/td><td>JZ (with GNYE)<\/td><td>1001408<\/td><td>24.9<\/td><td>816.0<\/td><td>1,325.0<\/td><td>100<\/td><td>374<\/td><\/tr><\/tbody><\/table><\/div><div class=\"scroll\"><table style=\"min-width:1400px\"><caption>Cross-section 4 mm\u00b2 \u00b7 UL 1 000 V \/ IEC 450\/750 V \u00b7 4 constructions<\/caption><thead><tr><th>Dimension n \u00d7 mm\u00b2<\/th><th>Version<\/th><th>Reference item no.<\/th><th>Outer \u00d8 (supp.) mm<\/th><th>Cu index kg\/km<\/th><th>Weight kg\/km<\/th><th>Min. bend radius fixed (4 \u00d7 d) mm<\/th><th>Min. bend radius moved (15 \u00d7 d) mm<\/th><\/tr><\/thead><tbody><tr><td>3 G 4<\/td><td>JZ (with GNYE)<\/td><td>1001413<\/td><td>9.3<\/td><td>115.2<\/td><td>194.0<\/td><td>37<\/td><td>140<\/td><\/tr><tr><td>4 G 4<\/td><td>JZ (with GNYE)<\/td><td>1001414<\/td><td>10.5<\/td><td>153.6<\/td><td>251.0<\/td><td>42<\/td><td>158<\/td><\/tr><tr><td>5 G 4<\/td><td>JZ (with GNYE)<\/td><td>1001416<\/td><td>11.5<\/td><td>192.0<\/td><td>312.0<\/td><td>46<\/td><td>172<\/td><\/tr><tr><td>7 G 4<\/td><td>JZ (with GNYE)<\/td><td>1001419<\/td><td>12.8<\/td><td>268.8<\/td><td>407.0<\/td><td>51<\/td><td>192<\/td><\/tr><\/tbody><\/table><\/div><div class=\"scroll\"><table style=\"min-width:1400px\"><caption>Cross-section 6 mm\u00b2 \u00b7 UL 1 000 V \/ IEC 450\/750 V \u00b7 4 constructions<\/caption><thead><tr><th>Dimension n \u00d7 mm\u00b2<\/th><th>Version<\/th><th>Reference item no.<\/th><th>Outer \u00d8 (supp.) mm<\/th><th>Cu index kg\/km<\/th><th>Weight kg\/km<\/th><th>Min. bend radius fixed (4 \u00d7 d) mm<\/th><th>Min. bend radius moved (15 \u00d7 d) mm<\/th><\/tr><\/thead><tbody><tr><td>3 G 6<\/td><td>JZ (with GNYE)<\/td><td>1001423<\/td><td>11.1<\/td><td>172.8<\/td><td>281.0<\/td><td>44<\/td><td>166<\/td><\/tr><tr><td>4 G 6<\/td><td>JZ (with GNYE)<\/td><td>1001424<\/td><td>12.4<\/td><td>230.4<\/td><td>360.0<\/td><td>50<\/td><td>186<\/td><\/tr><tr><td>5 G 6<\/td><td>JZ (with GNYE)<\/td><td>1001425<\/td><td>13.7<\/td><td>288.0<\/td><td>450.0<\/td><td>55<\/td><td>206<\/td><\/tr><tr><td>7 G 6<\/td><td>JZ (with GNYE)<\/td><td>1001427<\/td><td>15.3<\/td><td>403.2<\/td><td>591.0<\/td><td>61<\/td><td>230<\/td><\/tr><\/tbody><\/table><\/div><div class=\"scroll\"><table style=\"min-width:1400px\"><caption>Cross-section 10 mm\u00b2 \u00b7 UL 1 000 V \/ IEC 450\/750 V \u00b7 4 constructions<\/caption><thead><tr><th>Dimension n \u00d7 mm\u00b2<\/th><th>Version<\/th><th>Reference item no.<\/th><th>Outer \u00d8 (supp.) mm<\/th><th>Cu index kg\/km<\/th><th>Weight kg\/km<\/th><th>Min. bend radius fixed (4 \u00d7 d) mm<\/th><th>Min. bend radius moved (15 \u00d7 d) mm<\/th><\/tr><\/thead><tbody><tr><td>3 G 10<\/td><td>JZ (with GNYE)<\/td><td>1001428<\/td><td>14.5<\/td><td>288.0<\/td><td>463.0<\/td><td>58<\/td><td>218<\/td><\/tr><tr><td>4 G 10<\/td><td>JZ (with GNYE)<\/td><td>1001429<\/td><td>15.9<\/td><td>384.0<\/td><td>591.0<\/td><td>64<\/td><td>238<\/td><\/tr><tr><td>5 G 10<\/td><td>JZ (with GNYE)<\/td><td>1001431<\/td><td>17.9<\/td><td>480.0<\/td><td>738.0<\/td><td>72<\/td><td>268<\/td><\/tr><tr><td>7 G 10<\/td><td>JZ (with GNYE)<\/td><td>1001432<\/td><td>19.8<\/td><td>672.0<\/td><td>958.0<\/td><td>79<\/td><td>297<\/td><\/tr><\/tbody><\/table><\/div><div class=\"scroll\"><table style=\"min-width:1400px\"><caption>Cross-section 16 mm\u00b2 \u00b7 UL 1 000 V \/ IEC 450\/750 V \u00b7 4 constructions<\/caption><thead><tr><th>Dimension n \u00d7 mm\u00b2<\/th><th>Version<\/th><th>Reference item no.<\/th><th>Outer \u00d8 (supp.) mm<\/th><th>Cu index kg\/km<\/th><th>Weight kg\/km<\/th><th>Min. bend radius fixed (4 \u00d7 d) mm<\/th><th>Min. bend radius moved (15 \u00d7 d) mm<\/th><\/tr><\/thead><tbody><tr><td>3 G 16<\/td><td>JZ (with GNYE)<\/td><td>1001437<\/td><td>16.8<\/td><td>460.8<\/td><td>363.0<\/td><td>67<\/td><td>252<\/td><\/tr><tr><td>4 G 16<\/td><td>JZ (with GNYE)<\/td><td>1001438<\/td><td>18.7<\/td><td>614.4<\/td><td>864.0<\/td><td>75<\/td><td>280<\/td><\/tr><tr><td>5 G 16<\/td><td>JZ (with GNYE)<\/td><td>1001439<\/td><td>21.4<\/td><td>768.0<\/td><td>1,089.0<\/td><td>86<\/td><td>321<\/td><\/tr><tr><td>7 G 16<\/td><td>JZ (with GNYE)<\/td><td>1001440<\/td><td>23.6<\/td><td>1,075.2<\/td><td>1,439.0<\/td><td>94<\/td><td>354<\/td><\/tr><\/tbody><\/table><\/div><div class=\"scroll\"><table style=\"min-width:1400px\"><caption>Cross-section 25 mm\u00b2 \u00b7 UL 1 000 V \/ IEC 450\/750 V \u00b7 3 constructions<\/caption><thead><tr><th>Dimension n \u00d7 mm\u00b2<\/th><th>Version<\/th><th>Reference item no.<\/th><th>Outer \u00d8 (supp.) mm<\/th><th>Cu index kg\/km<\/th><th>Weight kg\/km<\/th><th>Min. bend radius fixed (4 \u00d7 d) mm<\/th><th>Min. bend radius moved (15 \u00d7 d) mm<\/th><\/tr><\/thead><tbody><tr><td>4 G 25<\/td><td>JZ (with GNYE)<\/td><td>1001442<\/td><td>23.8<\/td><td>960.0<\/td><td>1,359.0<\/td><td>95<\/td><td>357<\/td><\/tr><tr><td>5 G 25<\/td><td>JZ (with GNYE)<\/td><td>1001444<\/td><td>26.4<\/td><td>1,200.0<\/td><td>1,705.0<\/td><td>106<\/td><td>396<\/td><\/tr><tr><td>7 G 25<\/td><td>JZ (with GNYE)<\/td><td>1001445<\/td><td>29.5<\/td><td>1,680.0<\/td><td>2,246.0<\/td><td>118<\/td><td>442<\/td><\/tr><\/tbody><\/table><\/div><div class=\"scroll\"><table style=\"min-width:1400px\"><caption>Cross-section 35 mm\u00b2 \u00b7 UL 1 000 V \/ IEC 450\/750 V \u00b7 2 constructions<\/caption><thead><tr><th>Dimension n \u00d7 mm\u00b2<\/th><th>Version<\/th><th>Reference item no.<\/th><th>Outer \u00d8 (supp.) mm<\/th><th>Cu index kg\/km<\/th><th>Weight kg\/km<\/th><th>Min. bend radius fixed (4 \u00d7 d) mm<\/th><th>Min. bend radius moved (15 \u00d7 d) mm<\/th><\/tr><\/thead><tbody><tr><td>4 G 35<\/td><td>JZ (with GNYE)<\/td><td>1001449<\/td><td>26.7<\/td><td>1,344.0<\/td><td>1,826.0<\/td><td>107<\/td><td>400<\/td><\/tr><tr><td>5 G 35<\/td><td>JZ (with GNYE)<\/td><td>1001451<\/td><td>30.6<\/td><td>1,680.0<\/td><td>2,291.0<\/td><td>122<\/td><td>459<\/td><\/tr><\/tbody><\/table><\/div><div class=\"scroll\"><table style=\"min-width:1400px\"><caption>Cross-section 50 mm\u00b2 \u00b7 UL 1 000 V \/ IEC 450\/750 V \u00b7 2 constructions<\/caption><thead><tr><th>Dimension n \u00d7 mm\u00b2<\/th><th>Version<\/th><th>Reference item no.<\/th><th>Outer \u00d8 (supp.) mm<\/th><th>Cu index kg\/km<\/th><th>Weight kg\/km<\/th><th>Min. bend radius fixed (4 \u00d7 d) mm<\/th><th>Min. bend radius moved (15 \u00d7 d) mm<\/th><\/tr><\/thead><tbody><tr><td>3 G 50<\/td><td>JZ (with GNYE)<\/td><td>1001458<\/td><td>29.6<\/td><td>1,440.0<\/td><td>2,181.0<\/td><td>118<\/td><td>444<\/td><\/tr><tr><td>4 G 50<\/td><td>JZ (with GNYE)<\/td><td>1001459<\/td><td>32.6<\/td><td>1,920.0<\/td><td>2,767.0<\/td><td>130<\/td><td>489<\/td><\/tr><\/tbody><\/table><\/div><div class=\"scroll\"><table style=\"min-width:1400px\"><caption>Cross-section 70 mm\u00b2 \u00b7 UL 1 000 V \/ IEC 450\/750 V \u00b7 1 constructions<\/caption><thead><tr><th>Dimension n \u00d7 mm\u00b2<\/th><th>Version<\/th><th>Reference item no.<\/th><th>Outer \u00d8 (supp.) mm<\/th><th>Cu index kg\/km<\/th><th>Weight kg\/km<\/th><th>Min. bend radius fixed (4 \u00d7 d) mm<\/th><th>Min. bend radius moved (15 \u00d7 d) mm<\/th><\/tr><\/thead><tbody><tr><td>4 G 70<\/td><td>JZ (with GNYE)<\/td><td>1001460<\/td><td>37.6<\/td><td>2,688.0<\/td><td>3,733.0<\/td><td>150<\/td><td>564<\/td><\/tr><\/tbody><\/table><\/div><\/section>\n<section id=\"application\"><h2>6. Application envelope<\/h2><p>Power, control and connecting cable in electrical facilities where increased mineral-oil resistance is required. For fixed laying and flexible applications with free movement, without tensile stress and without forced guidance. Suitable for dry, humid and wet rooms. Outdoor use only with UV protection; not for burial. Where mechanical damage risk exists, install in tubes, channels or similar.<\/p><div class=\"svg\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 1900 820\" role=\"img\" aria-label=\"JZ application\"><rect width=\"100%\" height=\"100%\" fill=\"#06131b\"><\/rect><text x=\"65\" y=\"70\" fill=\"#55dff7\" font-family=\"Arial\" font-size=\"40\" font-weight=\"700\">Application envelope of \u00d6PVC-JZ\/OZ<\/text><g font-family=\"Arial\" fill=\"#eaf6fa\">\n<g transform=\"translate(60 130)\"><rect width=\"560\" height=\"500\" rx=\"20\" fill=\"#0c2630\" stroke=\"#62df9c\" stroke-width=\"4\"\/><text x=\"30\" y=\"55\" font-size=\"27\" font-weight=\"700\" fill=\"#62df9c\">\u2714 Control cabinets and panels<\/text>\n<rect x=\"60\" y=\"100\" width=\"200\" height=\"260\" fill=\"#123443\" stroke=\"#55dff7\" stroke-width=\"3\"\/><g fill=\"#55dff7\"><rect x=\"85\" y=\"130\" width=\"150\" height=\"16\"\/><rect x=\"85\" y=\"170\" width=\"150\" height=\"16\"\/><rect x=\"85\" y=\"210\" width=\"150\" height=\"16\"\/><\/g>\n<path d=\"M160 360V420H480\" stroke=\"#9aa6ab\" stroke-width=\"14\" fill=\"none\"\/><text x=\"30\" y=\"465\" font-size=\"19\">UL\/CSA panels for North American export<\/text><\/g>\n<g transform=\"translate(670 130)\"><rect width=\"560\" height=\"500\" rx=\"20\" fill=\"#0c2630\" stroke=\"#62df9c\" stroke-width=\"4\"\/><text x=\"30\" y=\"55\" font-size=\"27\" font-weight=\"700\" fill=\"#62df9c\">\u2714 Machine tools, oil mist, trays<\/text>\n<path d=\"M40 180H520\" stroke=\"#315b6f\" stroke-width=\"30\"\/><g stroke=\"#9aa6ab\" stroke-width=\"12\"><path d=\"M40 170H520\"\/><path d=\"M40 190H520\"\/><\/g>\n<path d=\"M300 200C300 300 420 280 440 380\" stroke=\"#9aa6ab\" stroke-width=\"12\" fill=\"none\"\/><rect x=\"400\" y=\"380\" width=\"100\" height=\"70\" fill=\"#123443\" stroke=\"#55dff7\" stroke-width=\"3\"\/>\n<text x=\"30\" y=\"465\" font-size=\"19\">Fixed laying; occasional free movement \u2265 15 \u00d7 d<\/text><\/g>\n<g transform=\"translate(1280 130)\"><rect width=\"560\" height=\"500\" rx=\"20\" fill=\"#0c2630\" stroke=\"#ff777f\" stroke-width=\"4\"\/><text x=\"30\" y=\"55\" font-size=\"27\" font-weight=\"700\" fill=\"#ff777f\">\u2718 Not designed for<\/text>\n<text x=\"30\" y=\"130\" font-size=\"21\">\u2022 Drag chains \/ forced guidance<\/text><text x=\"30\" y=\"180\" font-size=\"21\">\u2022 Tensile load, reels, festoons<\/text><text x=\"30\" y=\"230\" font-size=\"21\">\u2022 Direct burial<\/text><text x=\"30\" y=\"280\" font-size=\"21\">\u2022 Outdoors without UV protection<\/text><text x=\"30\" y=\"330\" font-size=\"21\">\u2022 Exposed routes without tube\/channel<\/text>\n<text x=\"30\" y=\"420\" font-size=\"18\" fill=\"#b8ccd3\">Where damage risk exists, install in tubes or channels;<\/text><text x=\"30\" y=\"450\" font-size=\"18\" fill=\"#b8ccd3\">for chains use a PUR\/TPE chain cable.<\/text><\/g>\n<rect x=\"60\" y=\"680\" width=\"1780\" height=\"100\" rx=\"18\" fill=\"#071821\" stroke=\"#315b6f\"\/><text x=\"100\" y=\"740\" font-size=\"21\" font-weight=\"700\" fill=\"#ffcf9c\">Suitable for dry, humid and wet rooms. Increased mineral-oil resistance plus IEC 60332-3-24 Cat. C for bunched runs.<\/text><\/g><\/svg><div class=\"svg-caption\">Figure 2: Permitted duties and exclusions.<\/div><\/div><\/section>\n<section id=\"compare\"><h2>7. Comparison<\/h2><div class=\"scroll\"><table style=\"min-width:1300px\"><caption>JZ\/OZ-Y\u00f6 UL\/CSA compared with related cables<\/caption><thead><tr><th>Type<\/th><th>Voltage<\/th><th>Test voltage<\/th><th>Fire<\/th><th>Oil<\/th><th>Typical use<\/th><\/tr><\/thead><tbody><tr><td>\u00d6PVC-JZ\/OZ (standard)<\/td><td>300\/500 V<\/td><td>4 kV<\/td><td>IEC 60332-1<\/td><td>TM54 oil resistance<\/td><td>IEC markets, general wiring<\/td><\/tr><tr><td><strong>\u00d6PVC-JZ\/OZ-Y\u00f6 UL\/CSA<\/strong><\/td><td><strong>UL 1 000 V \u00b7 IEC 450\/750 V<\/strong><\/td><td><strong>6 kV<\/strong><\/td><td><strong>IEC 60332-3-24 Cat. C, CSA FT1<\/strong><\/td><td><strong>Increased mineral-oil resistance<\/strong><\/td><td><strong>Machines exported to North America and Europe<\/strong><\/td><\/tr><tr><td>\u00d6PVC-JB\/OB-YCY<\/td><td>300\/500 V \u00b7 0.6\/1 kV<\/td><td>4 kV<\/td><td>IEC 60332-1<\/td><td>Largely oil-resistant<\/td><td>EMC-screened circuits<\/td><\/tr><tr><td>UL TC-ER (tray cable)<\/td><td>600 V<\/td><td>\u2014<\/td><td>UL 1685 \/ FT4<\/td><td>Per jacket<\/td><td>US tray installations, exposed runs<\/td><\/tr><\/tbody><\/table><\/div><\/section>\n<section id=\"design\"><h2>8. Design calculations<\/h2><div class=\"formula\">IEC installation: DIN VDE base rating \u00d7 f(ambient) \u00d7 f(grouping) \u00d7 f(loaded cores)\nUL\/NEC equipment: use the ampacity basis of the applicable product standard (e.g. NFPA 79 for industrial machinery)\nShort-circuit (PVC, Cu): I_k \u2248 115 \u00d7 S \/ \u221at   e.g. 4 G 70, t = 0.5 s \u2192 \u2248 11.4 kA\nVoltage drop: \u0394U = \u221a3 \u00d7 I \u00d7 L \u00d7 (R cos\u03c6 + X sin\u03c6)\nBending: fixed R \u2265 4 \u00d7 d \u00b7 moved R \u2265 15 \u00d7 d   e.g. 50 G 1.5 (d = 23.0 mm): 92 mm \/ 345 mm\nMoved below \u22125 \u00b0C: not permitted<\/div><\/section>\n<section id=\"quality\"><h2>9. Certification and traceability<\/h2><p>This cable carries cURus recognition (80 \u00b0C, 1 000 V) under UL Style 2570 and CSA AWM I A\/B II A\/B, meets IEC 60332-3-24 Cat. C, CEI 20-22 II, NBN C30-004 F2 and CSA FT1, and is RoHS-conform, CE-conform to 2014\/35\/EU and LABS-\/silicone-free during production. FeiChun Cable backs this with a complete export certification portfolio \u2014 including CE, UKCA, VDE, EAC, ATEX and IECEx \u2014 and every certificate supplied is checked against the exact type, voltage, factory and standard of the order.<\/p>\n<div class=\"cards\"><div class=\"card\"><h3>Routine tests<\/h3><p>Conductor resistance, 6 kV voltage test, insulation resistance, core numbering, dimensions and marking.<\/p><\/div><div class=\"card\"><h3>Type tests<\/h3><p>Bunched flame (IEC 60332-3-24 Cat. C), CSA FT1, mineral-oil immersion, sheath ageing.<\/p><\/div><div class=\"card\"><h3>Delivery documents<\/h3><p>Approved datasheet, test report per drum, UL\/CSA marking, batch number and length marking.<\/p><\/div><\/div><\/section>\n<section id=\"faq\"><h2>10. FAQ<\/h2><div class=\"cards\"><div class=\"card\"><h3>Why two voltage ratings?<\/h3><p>UL\/CSA AWM Style 2570 rates the cable at 1 000 V; under IEC it is rated 450\/750 V. One cable can therefore be used in a machine shipped to either market.<\/p><\/div><div class=\"card\"><h3>What does cURus mean?<\/h3><p>UL Recognized Component marking valid for both the US and Canada, here for 80 \u00b0C and 1 000 V as appliance wiring material (AWM).<\/p><\/div><div class=\"card\"><h3>Is AWM the same as a field-wiring tray cable?<\/h3><p>No. AWM is for wiring within equipment and machines. Field wiring in buildings under the NEC normally requires listed types such as TC-ER. Check the installation code.<\/p><\/div><div class=\"card\"><h3>What is IEC 60332-3-24 Cat. C?<\/h3><p>A bunched-cable vertical flame test: a defined non-metallic volume of cables must not propagate flame beyond a set height. It is stricter than the single-cable IEC 60332-1 test.<\/p><\/div><div class=\"card\"><h3>Why \u22125 \u00b0C when moved?<\/h3><p>The oil-resistant sheath compound is optimised for oil resistance and fire behaviour; below \u22125 \u00b0C, avoid flexing. Fixed installation remains possible down to \u221240 \u00b0C.<\/p><\/div><div class=\"card\"><h3>How many cores?<\/h3><p>From 2 to 50 cores in 0.5\u20131.5 mm\u00b2, up to 34 cores in 2.5 mm\u00b2, and up to 7 cores to 70 mm\u00b2.<\/p><\/div><\/div>\n<div class=\"contact\"><div><strong>FeiChun Cable \/ \u98de\u7eaf\u7535\u7f06<\/strong><br>Technical and project enquiries: <a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div><div><strong>Manufacturing in China, export support<\/strong><br><a href=\"tel:+8613855123218\">+86 13855123218<\/a><\/div><\/div><\/section><\/main>\n<footer><div class=\"wrap\"><div class=\"grid\"><div><div class=\"tag\">FEICHUN CABLE<\/div><h2>One oil-resistant control cable for IEC and UL\/CSA machines<\/h2><p class=\"small\">For machine tools, control panels and export equipment.<\/p><\/div><div><p><strong>Tech@feichuncables.com<\/strong><\/p><p><strong>+86 13855123218<\/strong><\/p><p class=\"small\">Document FC-ART-JZUL-2026-C267. Final values are governed by the approved datasheet, order drawing, batch test reports and certificate scope.<\/p><\/div><\/div><\/div><\/footer><\/body><\/html>\n","protected":false},"excerpt":{"rendered":"An engineering guide to a dual-rated PVC control cable: UL 1 000 V and IEC 450\/750 V, cURus 80 \u00b0C, increased mineral-oil resistance, a 6 kV test voltage and bunched-cable fire performance to IEC 60332-3-24 Cat. C and CSA FT1.","protected":false},"author":1,"featured_media":77201,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[13249,66,165,35,464,209,56,53617],"tags":[16,171,107,176,111,214,204,17],"class_list":["post-77200","post","type-post","status-publish","format-standard","has-post-thumbnail","category-bs-british-standard-cable","category-common-problems-encountered-in-cable-applications","category-drag-chain-cable","category-festoon-cable","category-flexible-cables-with-high-bending-life-and-fatigue-resistance","category-icea-s-75-381-portable-power-cables","category-reeling-cable","category-sts-crane-cable","tag-din-vde-0250","tag-explosion-proof-mining-cable","tag-heavy-duty-e-loader-mining-cable","tag-icea-s-75-381-2","tag-mining-cable","tag-mining-power-cable","tag-mining-trailing-cable","tag-reeling-cable","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/77200","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=77200"}],"version-history":[{"count":1,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/77200\/revisions"}],"predecessor-version":[{"id":77202,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/77200\/revisions\/77202"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/77201"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=77200"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=77200"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=77200"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}