{"id":7549,"date":"2026-02-27T10:14:13","date_gmt":"2026-02-27T02:14:13","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=7549"},"modified":"2026-02-27T11:21:40","modified_gmt":"2026-02-27T03:21:40","slug":"what-is-the-inner-and-outer-jacket-diameter-of-ntskcgewou-3x1503x25-3-3-6-6kv-splittable-earth-cable","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/what-is-the-inner-and-outer-jacket-diameter-of-ntskcgewou-3x1503x25-3-3-6-6kv-splittable-earth-cable\/","title":{"rendered":"What is the Inner and Outer Jacket Diameter of (N)TSKCGEW\u00d6U 3&#215;150+3&#215;25\/3 3.6\/6kV Splittable Earth Cable?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">A comprehensive engineering guide explaining the unique inner and outer jacket diameter specifications for (N)TSKCGEW\u00d6U 3&#215;150+3&#215;25\/3 3.6\/6kV medium-voltage reeling cables with split three-part symmetrical earth conductor design. Covers the fundamental differences between splittable earth cables and conventional designs, inner jacket functions and dimensions, outer jacket specifications and material properties, electromagnetic field symmetry principles and VFD benefits, VDE 0250-813 standards framework, manufacturing tolerance windows, and practical equipment integration considerations for large-scale mining and port machinery applications.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u2014 \u4e3a(N)TSKCGEW\u00d6U 3&#215;150+3&#215;25\/3 3.6\/6kV\u5206\u88c2\u5730\u7ebf\u7535\u7f06\u7684\u5185\u62a4\u5957\u4e0e\u5916\u62a4\u5957\u76f4\u5f84\u89c4\u683c\u63d0\u4f9b\u7efc\u5408\u5de5\u7a0b\u6307\u5357\u3002<\/em><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"a39587\" data-has-transparency=\"false\" style=\"--dominant-color: #a39587;\" loading=\"lazy\" decoding=\"async\" width=\"688\" height=\"444\" sizes=\"auto, (max-width: 688px) 100vw, 688px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-856.avif\" alt=\"\" class=\"wp-image-7550 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-856.avif 688w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-856-300x194.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-856-400x258.avif 400w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width,initial-scale=1.0\">\n<title>Inner vs. Outer Jacket Diameter of (N)TSKCGEW\u00d6U 3&#215;150+3&#215;25\/3 3.6\/6kV Splittable Earth Cable \u2014 Anhui Feichun<\/title>\n<meta name=\"description\" content=\"Comprehensive technical guide explaining the unique inner and outer jacket diameter specifications for (N)TSKCGEW\u00d6U 3x150+3x25\/3 3.6\/6kV cables with split three-part earth conductor design. Covers why splittable earth cables differ fundamentally from standard designs, inner jacket purposes and dimensions, outer jacket specifications, electromagnetic field symmetry benefits, VDE 0250-813 standards, manufacturing tolerances, and equipment integration considerations for heavy-duty mining and port machinery applications.\">\n<style>\n\/* ===== RESET & VARIABLES ===== *\/\n*,*::before,*::after{box-sizing:border-box;margin:0;padding:0}\n:root{\n--bg:#fff;--bg2:#f5f6f8;--bg3:#ebedf0;--tx:#16192b;--tx2:#4b5068;--tx3:#6e7489;\n--ac:#0059b3;--ac2:#003f7f;--acL:#dbeafe;--bd:#d2d6dc;\n--thBg:#0b1426;--thTx:#dde4ef;--trAlt:#f0f3f7;--hover:#eef2ff;\n--cardBg:#fff;--cardBd:#e3e7ed;--codeBg:#f1f4f9;--keyBg:#edf2ff;--keyBd:#0059b3;\n--shadow:0 1px 3px rgba(0,0,0,.07);--cn:#707890;\n--tagBg:#e6f0fd;--tagTx:#1a52c9;--gn:#15803d;--rd:#dc2626;--am:#d97706;\n--dangerBg:#fef2f2;--dangerBd:#f87171;--successBg:#f0fdf4;--successBd:#4ade80;\n--warnBg:#fffbeb;--warnBd:#fbbf24;\n}\n@media(prefers-color-scheme:dark){:root{\n--bg:#0e1018;--bg2:#181b2b;--bg3:#222640;--tx:#e0e5f0;--tx2:#9da5bf;--tx3:#6d7590;\n--ac:#6baafc;--ac2:#9cc5ff;--acL:#172b4d;--bd:#2b3050;\n--thBg:#0d1220;--thTx:#c8d0e0;--trAlt:#1c2038;--hover:#1d2a48;\n--cardBg:#181b2b;--cardBd:#2b3050;--codeBg:#1a2236;--keyBg:#152240;--keyBd:#5a9cf5;\n--shadow:0 1px 4px rgba(0,0,0,.3);--cn:#6d7590;\n--tagBg:#1a3560;--tagTx:#9cc5ff;--gn:#4ade80;--rd:#f87171;--am:#fbbf24;\n--dangerBg:#2a1215;--dangerBd:#ef4444;--successBg:#0f2a18;--successBd:#22c55e;\n--warnBg:#2a2210;--warnBd:#eab308;\n}}\n\/* ===== BASE ===== *\/\nhtml{font-size:16px;scroll-behavior:smooth}\nbody{font-family:-apple-system,BlinkMacSystemFont,'Segoe UI',Roboto,'Helvetica Neue',Arial,sans-serif;background:var(--bg);color:var(--tx);line-height:1.78}\na{color:var(--ac);text-decoration:none}a:hover{text-decoration:underline}\n.w{max-width:980px;margin:0 auto;padding:28px 22px 60px}\n.cn{color:var(--cn);font-size:.86em;font-style:italic}\n\n\/* ===== HEADER ===== *\/\n.hero{text-align:center;padding:44px 0 30px;border-bottom:2px solid var(--bd);margin-bottom:34px}\n.hero .co{font-size:.82rem;color:var(--ac);font-weight:700;letter-spacing:1.8px;text-transform:uppercase;margin-bottom:8px}\n.hero h1{font-size:1.7rem;font-weight:800;line-height:1.32;margin-bottom:12px}\n.hero .sub{font-size:.94rem;color:var(--tx2);max-width:700px;margin:0 auto}\n.meta{display:flex;flex-wrap:wrap;gap:10px 26px;font-size:.8rem;color:var(--tx3);padding-bottom:18px;border-bottom:1px solid var(--bd);margin-bottom:30px}\n\n\/* ===== TOC ===== *\/\n.toc{background:var(--bg2);border:1px solid var(--bd);border-radius:6px;padding:18px 22px;margin-bottom:32px}\n.toc h3{font-size:.85rem;text-transform:uppercase;letter-spacing:1px;color:var(--tx3);margin:0 0 10px;font-weight:700}\n.toc ol{padding-left:20px;font-size:.87rem;line-height:2.1}\n.toc a{color:var(--ac)}\n\n\/* ===== ARTICLE ===== *\/\narticle h2{font-size:1.32rem;font-weight:700;margin:38px 0 14px;padding-bottom:7px;border-bottom:2px solid var(--ac);display:inline-block}\narticle h3{font-size:1.08rem;font-weight:600;margin:22px 0 10px;color:var(--tx)}\narticle p{margin-bottom:15px;color:var(--tx2)}\narticle p.lead{font-size:1.01rem;color:var(--tx);font-weight:400}\n\n\/* ===== CALLOUT BOXES ===== *\/\n.box{padding:14px 18px;margin:18px 0;border-radius:0 6px 6px 0;border-left:4px solid}\n.box p{margin:0;font-size:.91rem}\n.box-key{background:var(--keyBg);border-color:var(--keyBd)}\n.box-danger{background:var(--dangerBg);border-color:var(--dangerBd)}\n.box-success{background:var(--successBg);border-color:var(--successBd)}\n.box-warn{background:var(--warnBg);border-color:var(--warnBd)}\n\n\/* ===== TABLES ===== *\/\n.tw{overflow-x:auto;margin:18px 0 26px;border:1px solid var(--bd);border-radius:6px}\ntable{width:100%;border-collapse:collapse;font-size:.86rem}\ntable caption{text-align:left;font-weight:700;font-size:.94rem;padding:11px 15px;background:var(--bg2);border-bottom:1px solid var(--bd)}\nthead{background:var(--thBg)}\nthead th{color:var(--thTx);font-weight:600;text-align:left;padding:9px 13px;white-space:nowrap;font-size:.8rem;text-transform:uppercase;letter-spacing:.5px}\ntbody td{padding:8px 13px;border-bottom:1px solid var(--bd);vertical-align:top}\ntbody tr:nth-child(even){background:var(--trAlt)}\ntbody tr:hover{background:var(--hover)}\ntd code,p code{background:var(--codeBg);padding:1px 5px;border-radius:3px;font-size:.85em;font-family:'SF Mono',Consolas,monospace}\n.vg{color:var(--gn);font-weight:600}.vr{color:var(--rd);font-weight:600}.va{color:var(--am);font-weight:600}\n\n\/* ===== STAT ROW ===== *\/\n.stats{display:grid;grid-template-columns:repeat(auto-fit,minmax(200px,1fr));gap:14px;margin:22px 0 28px}\n.stat{background:var(--bg2);border:1px solid var(--bd);border-radius:6px;padding:16px;text-align:center}\n.stat .num{font-size:1.6rem;font-weight:800;color:var(--ac);line-height:1.2}\n.stat .lbl{font-size:.78rem;color:var(--tx3);margin-top:4px;line-height:1.3}\n\n\/* ===== SOURCES ===== *\/\n.sources{margin-top:40px;padding-top:24px;border-top:2px solid var(--bd)}\n.sources ol{padding-left:22px;font-size:.82rem;color:var(--tx3);line-height:2}\n.sources a{color:var(--ac);word-break:break-all}\n\n\/* ===== CONTACT ===== *\/\n.contact{background:var(--bg2);border:1px solid var(--bd);border-radius:8px;padding:24px;margin-top:36px}\n.contact h2{border-bottom:none;margin-top:0;padding-bottom:0}\n.cg{display:grid;grid-template-columns:repeat(auto-fit,minmax(210px,1fr));gap:14px;margin-top:14px}\n.cc{background:var(--cardBg);border:1px solid var(--cardBd);border-radius:6px;padding:13px 15px}\n.cc .lb{font-size:.76rem;text-transform:uppercase;color:var(--tx3);letter-spacing:.5px;margin-bottom:3px;font-weight:600}\n.cc .vl{font-size:.9rem;color:var(--tx)}\n.cc a{color:var(--ac)}\n\nfooter{text-align:center;padding:28px 0 0;margin-top:38px;border-top:1px solid var(--bd);font-size:.78rem;color:var(--tx3)}\n@media(max-width:640px){\n .hero h1{font-size:1.3rem}.w{padding:16px 14px 40px}\n thead th,tbody td{padding:7px 8px;font-size:.79rem}\n .stats{grid-template-columns:1fr 1fr}\n}\n<\/style>\n<\/head>\n<body>\n<div class=\"w\">\n<!-- ===== HEADER ===== -->\n<header class=\"hero\">\n<div class=\"co\">Anhui Feichun Special Cable Co., Ltd. <span class=\"cn\">\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/span><\/div>\n<h1>What is the Inner and Outer Jacket Diameter of (N)TSKCGEW\u00d6U 3&#215;150+3&#215;25\/3 3.6\/6kV Splittable Earth Cable?<\/h1>\n<p class=\"sub\">A comprehensive engineering guide explaining the unique inner and outer jacket diameter specifications for (N)TSKCGEW\u00d6U 3&#215;150+3&#215;25\/3 3.6\/6kV medium-voltage reeling cables with split three-part symmetrical earth conductor design. Covers the fundamental differences between splittable earth cables and conventional designs, inner jacket functions and dimensions, outer jacket specifications and material properties, electromagnetic field symmetry principles and VFD benefits, VDE 0250-813 standards framework, manufacturing tolerance windows, and practical equipment integration considerations for large-scale mining and port machinery applications. <span class=\"cn\">\u2014 \u4e3a(N)TSKCGEW\u00d6U 3&#215;150+3&#215;25\/3 3.6\/6kV\u5206\u88c2\u5730\u7ebf\u7535\u7f06\u7684\u5185\u62a4\u5957\u4e0e\u5916\u62a4\u5957\u76f4\u5f84\u89c4\u683c\u63d0\u4f9b\u7efc\u5408\u5de5\u7a0b\u6307\u5357\u3002<\/span><\/p>\n<\/header>\n\n<div class=\"meta\">\n<span>Published: 2026<\/span>\n<span>Category: Medium-Voltage Split Earth Cable Engineering <span class=\"cn\">\u4e2d\u538b\u5206\u88c2\u5730\u7ebf\u7535\u7f06\u5de5\u7a0b<\/span><\/span>\n<span>Reading time: ~21 min<\/span>\n<\/div>\n\n<!-- ===== TOC ===== -->\n<nav class=\"toc\">\n<h3>Table of Contents <span class=\"cn\">\u76ee\u5f55<\/span><\/h3>\n<ol>\n<li><a href=\"#s1\">Direct Answer for Engineering Specs: Inner and Outer Jacket Diameters<\/a><\/li>\n<li><a href=\"#s2\">Why Splittable Earth Cables Require Different Dimensional Thinking<\/a><\/li>\n<li><a href=\"#s3\">Understanding Inner Jacket: Function and Dimensional Role<\/a><\/li>\n<li><a href=\"#s4\">Outer Jacket Specifications: Material and Dimensional Properties<\/a><\/li>\n<li><a href=\"#s5\">The 3&#215;25\/3 Split Earth Design: Geometry and Implications<\/a><\/li>\n<li><a href=\"#s6\">Component Stack-up: How Inner and Outer Dimensions Build<\/a><\/li>\n<li><a href=\"#s7\">Feichun Specifications: Precise Dimensions and Quality Control<\/a><\/li>\n<li><a href=\"#s8\">Electromagnetic Field Symmetry: Why This Design Matters for VFD<\/a><\/li>\n<li><a href=\"#s9\">VDE 0250-813 Standards: Tolerance Windows for Split Earth Cables<\/a><\/li>\n<li><a href=\"#s10\">Manufacturing Precision and Tolerance Control<\/a><\/li>\n<li><a href=\"#s11\">Field Measurement and Installation Verification<\/a><\/li>\n<li><a href=\"#s12\">References &#038; Sources<\/a><\/li>\n<\/ol>\n<\/nav>\n\n<article>\n<!-- ===== S1 ===== -->\n<h2 id=\"s1\">1. Direct Answer for Engineering Specs: Inner and Outer Jacket Diameters <span class=\"cn\">\u5de5\u7a0b\u89c4\u683c\u76f4\u63a5\u7b54\u6848\uff1a\u5185\u62a4\u5957\u4e0e\u5916\u62a4\u5957\u76f4\u5f84<\/span><\/h2>\n<p class=\"lead\">The nominal outer diameter of a (N)TSKCGEW\u00d6U 3&#215;150+3&#215;25\/3 3.6\/6kV cable with split three-part earth conductor is approximately <strong>65 mm (2.56 inches)<\/strong>, with a standard tolerance window of <strong>\u00b13.0 mm producing a permissible range of 62.0\u201368.0 mm<\/strong>. The inner jacket (the intermediate protective layer between the insulation and outer sheath) typically has a nominal thickness of approximately <strong>0.8\u20131.0 mm<\/strong>, contributing to overall diameter build-up but not typically measured as a separate &#8220;inner diameter&#8221; in engineering specifications because the inner jacket is not a defined outer boundary\u2014it is a layer embedded within the cable structure. The outer jacket (the final thermosetting rubber compound layer) has a nominal thickness of approximately <strong>2.5\u20133.0 mm<\/strong>, providing the cable&#8217;s mechanical interface with the environment. The approximate total weight of this cable is <strong>8,200 kg\/km (5,510 lbs\/1000 ft)<\/strong>, with copper content approximately <strong>4,560 kg\/km<\/strong>. It features three 150 mm\u00b2 Class 5 tinned copper main phase conductors, three strategically distributed 25\/3 mm\u00b2 split earth conductors for electromagnetic symmetry, a 3GI3 high-dielectric EPR insulation system rated for continuous 90\u00b0C operation, an anti-torsion braid reinforcement layer, and a 5GM5 thermosetting halogen-free outer sheath providing extreme abrasion and tear resistance.<\/p>\n\n<p>Understanding the distinction between inner and outer jacket specifications is essential because these layers serve fundamentally different functions. The inner jacket acts as an electrical stress distribution layer and moisture barrier, while the outer jacket provides mechanical protection and environmental resilience. For engineers integrating (N)TSKCGEW\u00d6U cables into large-scale reeling systems, the critical dimension for equipment compatibility is the outer diameter (62\u201368 mm nominal tolerance range), not the inner jacket thickness. However, understanding how the inner jacket dimensions contribute to the overall electromagnetic field symmetry illuminates why this cable design is specifically optimized for variable-frequency-drive (VFD) power distribution systems.<\/p>\n\n<div class=\"stats\">\n<div class=\"stat\"><div class=\"num\">65 mm<\/div><div class=\"lbl\">Nominal outer diameter (2.56 in.) <span class=\"cn\">\u540d\u4e49\u5916\u5f84<\/span><\/div><\/div>\n<div class=\"stat\"><div class=\"num\">62\u201368 mm<\/div><div class=\"lbl\">Tolerance window (standard) <span class=\"cn\">\u5bb9\u5dee\u7a97\u53e3<\/span><\/div><\/div>\n<div class=\"stat\"><div class=\"num\">0.8\u20131.0 mm<\/div><div class=\"lbl\">Inner jacket thickness <span class=\"cn\">\u5185\u62a4\u5957\u539a\u5ea6<\/span><\/div><\/div>\n<div class=\"stat\"><div class=\"num\">2.5\u20133.0 mm<\/div><div class=\"lbl\">Outer jacket thickness <span class=\"cn\">\u5916\u62a4\u5957\u539a\u5ea6<\/span><\/div><\/div>\n<\/div>\n\n<!-- ===== S2 ===== -->\n<h2 id=\"s2\">2. Why Splittable Earth Cables Require Different Dimensional Thinking <span class=\"cn\">\u4e3a\u4ec0\u4e48\u5206\u88c2\u5730\u7ebf\u7535\u7f06\u9700\u8981\u4e0d\u540c\u7684\u5c3a\u5bf8\u601d\u7ef4<\/span><\/h2>\n<p>Before discussing the specific inner and outer jacket dimensions of the (N)TSKCGEW\u00d6U cable, it is essential to understand why splittable earth cables\u2014those with three separate earth conductors (25\/3 mm\u00b2) distributed symmetrically around the three main phase conductors\u2014require a fundamentally different approach to dimensional specification than conventional cables with centralized earth conductors. This conceptual foundation will make the dimensional specifications much more meaningful.<\/p>\n\n<h3>2.1 Conventional Earth Conductor Geometry <span class=\"cn\">\u5e38\u89c4\u5730\u7ebf\u51e0\u4f55<\/span><\/h3>\n<p>A conventional medium-voltage cable with 3\u00d7150 mm\u00b2 phase conductors and earth protection typically features the three phase conductors arranged in a triangular or linear pattern, with one or more larger earth conductors (perhaps 3\u00d750 mm\u00b2 as a single conductor) positioned at the side or center of the cable structure. This conventional arrangement concentrates the earth conductor in a localized region of the cable&#8217;s cross-section, creating an asymmetric electromagnetic field around the cable. When this cable carries high-frequency VFD switching currents (typically 1\u201310 kHz for industrial variable-frequency drives), the asymmetric field distribution can induce harmonic interference in adjacent power and control circuits, creating EMC (electromagnetic compatibility) problems.<\/p>\n\n<h3>2.2 Splittable Earth Advantages <span class=\"cn\">\u5206\u88c2\u5730\u7ebf\u7684\u4f18\u52bf<\/span><\/h3>\n<p>The (N)TSKCGEW\u00d6U design addresses this problem by splitting the earth conductor into three separate 25\/3 mm\u00b2 conductors and distributing them symmetrically among the phase conductors. Instead of a single large earth conductor positioned at the cable&#8217;s edge, three smaller earth conductors are positioned between the phase conductors, creating a balanced three-fold symmetry throughout the cable&#8217;s cross-section. This geometric symmetry means that the magnetic field distribution around the cable is far more uniform, reducing harmonic interference and making the cable ideal for VFD power distribution where high-frequency switching noise would otherwise cause problems.<\/p>\n\n<p>The &#8220;splittable&#8221; designation indicates that during termination, these three separate earth conductors can be combined (twisted together) to form a single earth terminal, or they can remain separate if the equipment design requires multiple grounding points. This flexibility is why the designation includes &#8220;splittable&#8221;\u2014the three earth conductors can be kept split or combined as needed during installation.<\/p>\n\n<!-- ===== S3 ===== -->\n<h2 id=\"s3\">3. Understanding Inner Jacket: Function and Dimensional Role <span class=\"cn\">\u7406\u89e3\u5185\u62a4\u5957\uff1a\u529f\u80fd\u548c\u5c3a\u5bf8\u4f5c\u7528<\/span><\/h2>\n<p>The inner jacket in a (N)TSKCGEW\u00d6U cable is a layer of thermosetting rubber material (typically neoprene or a specialized compound) applied directly over the insulation layers and the conductor shield braids. This inner jacket serves multiple critical functions that are often overlooked by engineers who focus only on outer diameter specifications.<\/p>\n\n<h3>3.1 Electrical Stress Distribution <span class=\"cn\">\u7535\u6c14\u5e94\u529b\u5206\u5e03<\/span><\/h3>\n<p>The primary function of the inner jacket is electrical stress distribution. The insulation around each conductor (3GI3 EPR material) must be thick enough to withstand the rated voltage (3.6\/6 kV) while maintaining flexibility for dynamic bending. However, the insulation thickness is not perfectly uniform\u2014there are inherent variations from the extrusion process, and the conductor surface may have minor irregularities. The inner jacket, positioned directly over the insulation, provides a smooth interface that helps distribute electrical stress evenly across the insulation surface. This prevents stress concentration at minor irregularities that could eventually lead to partial discharge and insulation failure. For a 3.6\/6 kV cable, this stress distribution is important because the voltage stress on the insulation is already relatively high, and any concentration can significantly shorten service life.<\/p>\n\n<h3>3.2 Moisture Barrier <span class=\"cn\">\u6c34\u5206\u5c4f\u969c<\/span><\/h3>\n<p>The inner jacket also acts as a moisture barrier. Mining and port environments are inherently damp\u2014cables are exposed to rain, salt spray, and high humidity. Moisture infiltration through the outer jacket (even microscopic cracks) would eventually reach the insulation layers if not for the inner jacket barrier. The inner jacket material (typically neoprene or chlorinated rubber) resists moisture penetration far better than the insulation materials alone, adding a secondary protection layer. This redundancy is crucial for cables that may remain in service for 15\u201320 years in harsh outdoor environments.<\/p>\n\n<h3>3.3 Dimensional Contribution and Non-Critical Nature <span class=\"cn\">\u5c3a\u5bf8\u8d21\u732e\u548c\u975e\u5173\u952e\u6027\u8d28<\/span><\/h3>\n<p>The inner jacket contributes approximately 0.8\u20131.0 mm thickness to the overall cable diameter. However, unlike the outer diameter specification (which is critical for reel bore compatibility, terminal connector sizing, and equipment integration), the inner jacket thickness is not typically specified as a controlled dimension in procurement documents. The inner jacket thickness varies somewhat depending on the manufacturing process and is controlled primarily by its functional performance (voltage stress distribution, moisture resistance) rather than by precise geometric specification. Engineers designing reel systems and terminal equipment base their specifications on the cable&#8217;s outer diameter (62\u201368 mm for this model), not on inner jacket thickness, because the inner jacket is an internal structural component, not an external interface dimension.<\/p>\n\n<!-- ===== S4 ===== -->\n<h2 id=\"s4\">4. Outer Jacket Specifications: Material and Dimensional Properties <span class=\"cn\">\u5916\u62a4\u5957\u89c4\u683c\uff1a\u6750\u6599\u548c\u5c3a\u5bf8\u7279\u6027<\/span><\/h2>\n<p>The outer jacket is the cable&#8217;s final protective layer\u2014the component that directly interfaces with the environment. For the (N)TSKCGEW\u00d6U cable designed for heavy-duty mining and port machinery use, the outer jacket is manufactured from 5GM5 material, a specialized thermosetting elastomer formulation optimized for extreme durability in harsh industrial environments.<\/p>\n\n<h3>4.1 5GM5 Material Properties <span class=\"cn\">5GM5\u6750\u6599\u7279\u6027<\/span><\/h3>\n<p>The 5GM5 designation indicates a halogen-free thermosetting compound (chlorinated rubber or polyurethane-based) specifically formulated for marine and mining applications. The &#8220;5GM&#8221; portion refers to the base elastomer type (typically a chlorinated polyethylene variant), and the &#8220;5&#8221; indicates a particular formulation level optimized for heavy-duty industrial use. This material offers exceptional resistance to abrasion (critical for cables dragged across rocky mine floors), superior tear resistance (important for cables handling sudden mechanical shocks), excellent UV resistance (enabling long-term outdoor storage without degradation), strong oil and chemical resistance (for exposure to diesel fuel, hydraulic fluid, and industrial solvents), and inherent flame-retardance meeting IEC 60332-1-2 standards.<\/p>\n\n<h3>4.2 Thickness and Tolerance <span class=\"cn\">\u539a\u5ea6\u548c\u5bb9\u5dee<\/span><\/h3>\n<p>The outer jacket nominal thickness for a (N)TSKCGEW\u00d6U 3&#215;150+3&#215;25\/3 cable is approximately 2.5\u20133.0 mm. This thickness is the result of extrusion process design choices that balance mechanical protection against weight and cost. A thicker jacket (3.5+ mm) would provide additional abrasion protection but would increase cable weight and cost. A thinner jacket (2.0 mm) would reduce weight but might not provide adequate protection for the cable&#8217;s intended heavy-duty mining and port applications. The nominal 2.5\u20133.0 mm thickness represents engineering consensus on the appropriate balance for these specific operating environments.<\/p>\n\n<h3>4.3 Why Outer Jacket Thickness Varies <span class=\"cn\">\u5916\u62a4\u5957\u539a\u5ea6\u4e3a\u4f55\u53d8\u5316<\/span><\/h3>\n<p>Outer jacket thickness is subject to manufacturing tolerance because the extrusion process (where the jacket material is applied to the underlying cable) is inherently variable. Temperature variations in the extrusion head, pressure fluctuations, material batch variations, and line speed changes all influence the final jacket thickness by \u00b10.3\u20130.5 mm. Manufacturers typically specify outer jacket thickness tolerance of \u00b10.5\u20130.7 mm, meaning actual production might range from 2.0 mm to 3.5 mm. However, this variation is acceptable because the outer jacket is a protective layer\u2014it needs to provide adequate protection, but its thickness does not affect electrical or mechanical performance within the tolerance range. In contrast, outer diameter (the cumulative effect of all layers including the outer jacket) is tightly controlled because it directly affects equipment compatibility.<\/p>\n\n<!-- ===== S5 ===== -->\n<h2 id=\"s5\">5. The 3&#215;25\/3 Split Earth Design: Geometry and Implications <span class=\"cn\">3&#215;25\/3\u5206\u88c2\u5730\u7ebf\u8bbe\u8ba1\uff1a\u51e0\u4f55\u548c\u542b\u4e49<\/span><\/h2>\n<p>The designation &#8220;3&#215;25\/3&#8221; in the (N)TSKCGEW\u00d6U specification indicates three separate earth conductors, each nominally 25\/3 mm\u00b2 (where the &#8220;\/3&#8221; indicates these are three parallel strands rather than a single solid conductor of that cross-section, providing enhanced flexibility). Understanding how these three conductors are positioned within the cable structure illuminates why the cable achieves its electromagnetic symmetry and why overall outer diameter is designed as it is.<\/p>\n\n<h3>5.1 Positioning Strategy <span class=\"cn\">\u5b9a\u4f4d\u7b56\u7565<\/span><\/h3>\n<p>The three main phase conductors (3\u00d7150 mm\u00b2) are arranged in a triangular or linear pattern. The three split earth conductors are then positioned in the &#8220;gaps&#8221; or spaces between the phase conductors, creating a distributed geometry where earth conductors are interleaved with phase conductors rather than concentrated in one region. This interleaved arrangement requires careful spatial planning during cable design to ensure that all components fit within the target outer diameter while maintaining appropriate insulation distances (the minimum thickness of insulation material that must separate conductors for electrical safety).<\/p>\n\n<h3>5.2 Impact on Outer Diameter <span class=\"cn\">\u5bf9\u5916\u5f84\u7684\u5f71\u54cd<\/span><\/h3>\n<p>The split earth design results in a nominally larger outer diameter (65 mm) compared to what might be achieved with a conventional centralized earth conductor approach. This diameter increase reflects the spatial requirements of distributing three separate earth conductors throughout the cable cross-section while maintaining required insulation thicknesses and proper stress distribution. The trade-off is worthwhile because the diameter increase is modest (approximately 3\u20135 mm compared to conventional design), while the electromagnetic field symmetry benefit is substantial\u2014making the cable far more suitable for high-frequency VFD power distribution where harmonic interference would otherwise be problematic.<\/p>\n\n<!-- ===== S6 ===== -->\n<h2 id=\"s6\">6. Component Stack-up: How Inner and Outer Dimensions Build <span class=\"cn\">\u7ec4\u4ef6\u5806\u79ef\uff1a\u5185\u5f84\u548c\u5916\u5f84\u5982\u4f55\u6784\u5efa<\/span><\/h2>\n<p>Understanding how the cable&#8217;s final dimensions are built from component layers helps explain why both inner and outer jacket thicknesses are important to the engineering design, even though outer diameter is the specified dimension that equipment manufacturers use for integration planning.<\/p>\n\n<div class=\"tw\">\n<table>\n<caption>Table 1 \u2014 (N)TSKCGEW\u00d6U Component Stack-up and Dimensional Contribution <span class=\"cn\">\u7ec4\u4ef6\u5806\u79ef\u548c\u5c3a\u5bf8\u8d21\u732e<\/span><\/caption>\n<thead><tr><th>Component Layer <span class=\"cn\">\u7ec4\u4ef6\u5c42<\/span><\/th><th>Nominal Thickness <span class=\"cn\">\u540d\u4e49\u539a\u5ea6<\/span><\/th><th>Cumulative Contribution to Outer Diameter <span class=\"cn\">\u5bf9\u5916\u5f84\u7684\u7d2f\u79ef\u8d21\u732e<\/span><\/th><th>Function <span class=\"cn\">\u529f\u80fd<\/span><\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Three 150 mm\u00b2 phase conductors (avg. center-to-center arrangement) <span class=\"cn\">\u4e09\u6839150 mm\u00b2\u76f8\u7ebf<\/span><\/td><td>~19 mm (conductor diameter)<\/td><td>~38 mm total width<\/td><td>Electrical power carrying; Class 5 fine stranding for flexibility<\/td><\/tr>\n<tr><td>Insulation (3GI3 EPR, ~2.8 mm per conductor side) <span class=\"cn\">\u7edd\u7f18<\/span><\/td><td>~5.6 mm per phase conductor<\/td><td>+~11 mm to diameter<\/td><td>Voltage isolation; stress distribution foundation<\/td><\/tr>\n<tr><td>Split earth conductors (3\u00d725\/3 mm\u00b2, distributed) <span class=\"cn\">\u5206\u88c2\u5730\u7ebf<\/span><\/td><td>~13 mm (three conductors with spacing)<\/td><td>~13\u201315 mm (distributed, not concentrated)<\/td><td>Protective earthing; symmetrical field distribution<\/td><\/tr>\n<tr><td>Inner jacket (neoprene or specialized compound) <span class=\"cn\">\u5185\u62a4\u5957<\/span><\/td><td>~0.8\u20131.0 mm<\/td><td>+~1.6\u20132.0 mm to diameter<\/td><td>Electrical stress distribution; moisture barrier<\/td><\/tr>\n<tr><td>Anti-torsion braid (polyester or aramid fiber) <span class=\"cn\">\u9632\u626d\u7f16\u7ec7<\/span><\/td><td>~1.5\u20132.0 mm coverage<\/td><td>+~3.0\u20134.0 mm to diameter<\/td><td>Prevents Z-shaped twisting during high-speed reeling<\/td><\/tr>\n<tr><td>Outer jacket (5GM5, halogen-free thermosetting) <span class=\"cn\">\u5916\u62a4\u5957<\/span><\/td><td>~2.5\u20133.0 mm<\/td><td>+~5.0\u20136.0 mm to diameter<\/td><td>Mechanical protection; environmental resilience; abrasion resistance<\/td><\/tr>\n<tr><td><strong>Total accumulated layers<\/strong><\/td><td><strong>Nominal design: ~65 mm<\/strong><\/td><td><strong>Standard tolerance: 62\u201368 mm (\u00b13 mm)<\/strong><\/td><td><strong>Equipment integration dimension<\/strong><\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<p>This stack-up table illustrates how the final outer diameter is not merely the sum of inner components but rather the result of careful geometric design that positions components within space-constrained dimensions while achieving electrical safety and mechanical performance. The inner jacket thickness (0.8\u20131.0 mm) is small compared to other layers but is essential for proper electrical function. The outer jacket thickness (2.5\u20133.0 mm) is the cable&#8217;s primary environmental interface and must be robust enough for the intended application. Together, all components produce a cable with nominal outer diameter of 65 mm and standard tolerance range of 62\u201368 mm, which is the dimension that equipment manufacturers use for reel bore sizing, terminal connector design, and integration planning.<\/p>\n\n<!-- ===== S7 ===== -->\n<h2 id=\"s7\">7. Feichun Specifications: Precise Dimensions and Quality Control <span class=\"cn\">\u98de\u7eaf\u89c4\u683c\uff1a\u7cbe\u786e\u5c3a\u5bf8\u4e0e\u8d28\u91cf\u63a7\u5236<\/span><\/h2>\n<p>Anhui Feichun manufactures (N)TSKCGEW\u00d6U 3&#215;150+3&#215;25\/3 3.6\/6kV cables with the following dimensional specifications, reflecting our commitment to precision engineering and compatibility with global mining and port equipment standards.<\/p>\n\n<div class=\"tw\">\n<table>\n<caption>Table 2 \u2014 Anhui Feichun (N)TSKCGEW\u00d6U Outer Diameter and Jacket Specification <span class=\"cn\">\u5b89\u5fbd\u98de\u7eaf(N)TSKCGEW\u00d6U\u5c3a\u5bf8\u89c4\u683c<\/span><\/caption>\n<thead><tr><th>Dimension Parameter <span class=\"cn\">\u5c3a\u5bf8\u53c2\u6570<\/span><\/th><th>Nominal Value <span class=\"cn\">\u540d\u4e49\u503c<\/span><\/th><th>Standard Tolerance<br>(VDE 0250-813)<span style=\"font-weight:400;font-size:.72rem\">\u6807\u51c6\u5bb9\u5dee<\/span><\/th><th>Typical Production<br>Range<span style=\"font-weight:400;font-size:.72rem\">95% of output<\/span><\/th><th>Engineering Note <span class=\"cn\">\u5de5\u7a0b\u8bf4\u660e<\/span><\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Nominal outer diameter (O.D.) <span class=\"cn\">\u540d\u4e49\u5916\u5f84<\/span><\/td><td class=\"vg\">65 mm (2.56 in.)<\/td><td>\u00b13.0 mm<\/td><td>63.5\u201366.5 mm<\/td><td>Design target for reel bore compatibility; symmetrical split earth positioning achieved<\/td><\/tr>\n<tr><td>Maximum outer diameter <span class=\"cn\">\u6700\u5927\u5916\u5f84<\/span><\/td><td>\u2014<\/td><td>68.0 mm<\/td><td>Upper tolerance extreme (rare in production)<\/td><td>Standard upper limit; cables rarely approach this value due to process control<\/td><\/tr>\n<tr><td>Inner jacket thickness <span class=\"cn\">\u5185\u62a4\u5957\u539a\u5ea6<\/span><\/td><td>0.9 mm<\/td><td>\u00b10.2 mm<\/td><td>0.7\u20131.1 mm<\/td><td>Electrical stress distribution and moisture barrier function<\/td><\/tr>\n<tr><td>Outer jacket thickness <span class=\"cn\">\u5916\u62a4\u5957\u539a\u5ea6<\/span><\/td><td>2.8 mm (5GM5)<\/td><td>\u00b10.5 mm<\/td><td>2.3\u20133.3 mm<\/td><td>Abrasion and tear resistance; environmental protection; halogen-free for safety<\/td><\/tr>\n<tr><td>Anti-torsion braid layer <span class=\"cn\">\u9632\u626d\u7f16\u7ec7\u5c42<\/span><\/td><td>~1.8 mm coverage<\/td><td>\u00b10.3 mm<\/td><td>1.5\u20132.1 mm<\/td><td>Prevents cable twisting during dynamic reeling; high-strength polyester or aramid<\/td><\/tr>\n<tr><td>Design symmetry (phase-earth interleaving) <span class=\"cn\">\u8bbe\u8ba1\u5bf9\u79f0\u6027<\/span><\/td><td class=\"vg\">3-fold rotational symmetry<\/td><td>\u00b10.1 (geometric tolerance)<\/td><td>Validated through measurement<\/td><td>VFD compatibility; reduces harmonic interference in high-frequency power distribution<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<p>Our (N)TSKCGEW\u00d6U cables are engineered to meet VDE 0250-813 requirements while maintaining tight process control that keeps actual production within \u00b12.0 mm of nominal outer diameter (tighter than the standard \u00b13.0 mm requirement). This precision ensures reliable compatibility with all standard mining and port equipment designed around the nominal 65 mm specification. Our inner jacket formulation provides optimized electrical stress distribution for 3.6\/6 kV operation, while our 5GM5 outer jacket provides extreme durability in harsh coastal and mining environments. The anti-torsion braid is manufactured from high-strength polyester or aramid fiber, providing rated torsion resistance of \u00b128\u00b0\/m even during dynamic high-speed reeling operations typical of modern mining draglines and port unloader systems.<\/p>\n\n<!-- ===== S8 ===== -->\n<h2 id=\"s8\">8. Electromagnetic Field Symmetry: Why This Design Matters for VFD <span class=\"cn\">\u7535\u78c1\u573a\u5bf9\u79f0\u6027\uff1a\u4e3a\u4ec0\u4e48\u8fd9\u79cd\u8bbe\u8ba1\u5bf9VFD\u5f88\u91cd\u8981<\/span><\/h2>\n<p>The split three-part earth conductor design of the (N)TSKCGEW\u00d6U cable is not merely a cost optimization or manufacturing convenience\u2014it is a deliberate engineering choice that addresses a specific problem in modern variable-frequency-drive power distribution systems. Understanding this engineering rationale helps explain why the cable&#8217;s geometry (and therefore its outer diameter) is designed as it is.<\/p>\n\n<h3>8.1 VFD Switching Noise and Harmonic Interference <span class=\"cn\">VFD\u5f00\u5173\u566a\u58f0\u548c\u8c10\u6ce2\u5e72\u6270<\/span><\/h3>\n<p>Variable-frequency drives operate by using rapid switching circuits (typically switching at 1\u201310 kHz) to create variable voltage waveforms that control motor speed. These high-frequency switching currents travel down the power cable and create rapidly changing magnetic fields around the cable. For conventional cables with centralized earth conductors, this magnetic field distribution is asymmetric\u2014the field strength varies significantly around the cable&#8217;s circumference because the high-frequency switching current is concentrated in one location on the cable&#8217;s cross-section. This asymmetric field can induce voltages in adjacent power and control cables, creating harmonic interference that disrupts sensitive electronics.<\/p>\n\n<h3>8.2 Symmetry as the Solution <span class=\"cn\">\u5bf9\u79f0\u6027\u4f5c\u4e3a\u89e3\u51b3\u65b9\u6848<\/span><\/h3>\n<p>The split three-part earth conductor design addresses this problem by distributing the return current path symmetrically around the cable&#8217;s circumference. With three separate earth conductors positioned at 120-degree intervals around the three phase conductors, the magnetic field produced by the VFD switching currents is distributed evenly in all directions. This symmetry means the magnetic field does not preferentially couple into adjacent cables, dramatically reducing harmonic interference. The electromagnetic compatibility improvement is substantial and is why modern mining draglines, port container handling equipment, and large industrial drives increasingly specify (N)TSKCGEW\u00d6U or similar split-earth-conductor designs rather than conventional cables.<\/p>\n\n<!-- ===== S9 ===== -->\n<h2 id=\"s9\">9. VDE 0250-813 Standards: Tolerance Windows for Split Earth Cables <span class=\"cn\">VDE 0250-813\u6807\u51c6\uff1a\u5206\u88c2\u5730\u7ebf\u7535\u7f06\u7684\u5bb9\u5dee\u7a97\u53e3<\/span><\/h2>\n<p>The VDE 0250-813 standard (harmonized with IEC and international standards) establishes the dimensional framework for reeling cables including those with split earth conductor designs. The standard permits certain flexibility in cable geometry\u2014recognizing that different manufacturers may achieve the same electrical and mechanical performance through slightly different design approaches\u2014but establishes tolerance windows ensuring compatibility with standard equipment.<\/p>\n\n<p>For (N)TSKCGEW\u00d6U cables, VDE 0250-813 specifies nominal outer diameter and a \u00b13.0 mm tolerance window. This tolerance range represents engineering consensus that manufacturing processes for cables this size can reliably hold \u00b13.0 mm precision. Cable manufacturers achieving tighter process control (\u00b12.0 mm or \u00b11.5 mm) exceed the standard requirement and typically advertise this as a quality advantage. Manufacturers operating at the loose end of tolerance (\u00b13.0 mm) still meet the standard but may have equipment compatibility issues with more tightly engineered reel systems.<\/p>\n\n<!-- ===== S10 ===== -->\n<h2 id=\"s10\">10. Manufacturing Precision and Tolerance Control <span class=\"cn\">\u5236\u9020\u7cbe\u5ea6\u4e0e\u5bb9\u5dee\u63a7\u5236<\/span><\/h2>\n<p>Achieving precise outer diameter specifications for cables with complex geometry (three phase conductors, three split earth conductors, anti-torsion braid, inner and outer jackets) requires sophisticated process control. Each extrusion layer\u2014insulation, inner jacket, anti-torsion braid, outer jacket\u2014adds thickness tolerance. The cumulative effect determines the final outer diameter tolerance.<\/p>\n\n<p>Premium cable manufacturers invest in laser diameter measurement systems that monitor outer diameter in real-time during extrusion. If the cable drifts outside the target tolerance window, the operator immediately adjusts extrusion temperature or line speed to bring production back into specification. This active control allows manufacturers to maintain tighter tolerances (\u00b11.5\u20132.0 mm) than the standard minimum requires, ensuring better compatibility with equipment designed around the nominal specification and reducing the risk of undersized or oversized cables being produced.<\/p>\n\n<!-- ===== S11 ===== -->\n<h2 id=\"s11\">11. Field Measurement and Installation Verification <span class=\"cn\">\u73b0\u573a\u6d4b\u91cf\u4e0e\u5b89\u88c5\u9a8c\u8bc1<\/span><\/h2>\n<p>Before integrating (N)TSKCGEW\u00d6U cables into large mining or port equipment, implement verification procedures to confirm proper cable fit in reel bores, terminal connectors, and other equipment components.<\/p>\n\n<p>Use a digital caliper or precision micrometer to measure cable outer diameter at minimum five locations along the cable length (e.g., at 100 m intervals for a 500 m delivery). Record all measurements and calculate mean, minimum, maximum, and standard deviation. Verify that all measurements fall within the expected tolerance range (62\u201368 mm). If any measurements exceed this range, contact the cable manufacturer before attempting installation\u2014undersized or oversized cables may not seat properly in equipment designed for the nominal specification.<\/p>\n\n<\/article>\n\n<!-- ===== REFERENCES ===== -->\n<section class=\"sources\" id=\"s12\">\n<h2>References &#038; Sources <span class=\"cn\">\u53c2\u8003\u6765\u6e90<\/span><\/h2>\n<ol>\n<li>VDE 0250-813 \u2014 &#8220;Cables; stranded bare or insulated round wires for equipment; reeling cables.&#8221; Verband der Elektrotechnik Elektronik Informationstechnik, current edition. Establishes dimensional and performance requirements for (N)TSKCGEW\u00d6U and similar cables.<\/li>\n<li>IEC 60228 \u2014 &#8220;Conductors of insulated cables.&#8221; Class 5 conductor specifications and flexibility standards.<\/li>\n<li>IEC 60811 \u2014 &#8220;Insulation and sheath materials of cables. Test methods for non-metallic materials.&#8221; Material and dimensional testing procedures.<\/li>\n<li>IEC 60092-353 \u2014 &#8220;Electrical installations in ships \u2014 Part 353: Cables with a voltage rating up to and including 35 kV.&#8221; Harmonized cable performance standards applicable to industrial reeling cables.<\/li>\n<li>Anhui Feichun Special Cable Co., Ltd. \u2014 &#8220;(N)TSKCGEW\u00d6U Cable Technical Specifications and Manufacturing Standards.&#8221; Production data and quality assurance documentation. <a href=\"https:\/\/feichuncables.com\" rel=\"nofollow\" target=\"_blank\">www.feichuncables.com<\/a><\/li>\n<\/ol>\n<\/section>\n\n<!-- ===== CONTACT ===== -->\n<section class=\"contact\">\n<h2>Contact Anhui Feichun Special Cable <span class=\"cn\">\u8054\u7cfb\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06<\/span><\/h2>\n<p style=\"font-size:.88rem;color:var(--tx2);margin-bottom:4px\">For (N)TSKCGEW\u00d6U 3&#215;150+3&#215;25\/3 3.6\/6kV cable specifications, split earth conductor design consultation, inner and outer jacket dimension details, VFD compatibility support, mining equipment integration, port machinery specifications, dimensional verification services, or technical guidance ensuring proper cable selection and installation for your heavy-duty reeling applications, contact our team directly. We provide comprehensive dimensional data, process control documentation, field verification support, and equipment integration consulting. <span class=\"cn\">\n<footer>\n<p>&copy; 2026 Anhui Feichun Special Cable Co., Ltd. <span class=\"cn\">\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/span>. All rights reserved.<\/p>\n<p style=\"margin-top:5px\"><a href=\"https:\/\/feichuncables.com\" rel=\"nofollow\" target=\"_blank\" style=\"color:var(--ac)\">feichuncables.com<\/a><\/p>\n<\/footer>\n<\/div>\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"(N)TSKCGEW\u00d6U 3&#215;150+3&#215;25\/3 3.6\/6kV cable with split three-part earth conductor is approximately 65 mm (2.56 inches), with a standard tolerance window of \u00b13.0 mm producing a permissible range of 62.0\u201368.0 mm. The inner jacket (the intermediate protective layer between the insulation and outer sheath) typically has a nominal thickness of approximately 0.8\u20131.0 mm, contributing to overall diameter build-up but not typically measured as a separate &#8220;inner diameter&#8221; in engineering specifications because the inner jacket is not a defined outer boundary\u2014it is a layer embedded within the cable structure. The outer jacket (the final thermosetting rubber compound layer) has a nominal thickness of approximately 2.5\u20133.0 mm, providing the cable&#8217;s mechanical interface with the environment. The approximate total weight of this cable is 8,200 kg\/km (5,510 lbs\/1000 ft), with copper content approximately 4,560 kg\/km. It features three 150 mm\u00b2 Class 5 tinned copper main phase conductors, three strategically distributed 25\/3 mm\u00b2 split earth conductors for electromagnetic symmetry, a 3GI3 high-dielectric EPR insulation system rated for continuous 90\u00b0C operation, an anti-torsion braid reinforcement layer, and a 5GM5 thermosetting halogen-free outer sheath providing extreme abrasion and tear resistance.","protected":false},"author":1,"featured_media":7550,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[66,464,7,56],"tags":[21643,42,12622,41290,44077,6370,5647,44078,3715,4562,1617,1043,41583,44082,2368,44083,16,36534,43982,820,171,1685,774,1002,152,32764,107,5779,2678,176,4813,29696,44079,1092,138,111,139,44084,214,4308,44080,796,1951,44085,17,3186,2782,6115,2373,5558,2604,7573,44031,2790,766,38442,808,32424,44081],"class_list":["post-7549","post","type-post","status-publish","format-standard","has-post-thumbnail","category-common-problems-encountered-in-cable-applications","category-flexible-cables-with-high-bending-life-and-fatigue-resistance","category-mining-trailing-cable","category-reeling-cable","tag-ntscgewou-cable-2","tag-ntskcgewou","tag-3-6-6kv-reeling-cable","tag-3gi3-insulation","tag-3x1503x25-3-cable","tag-5gm5-outer-sheath","tag-6kv-mining-cable","tag-anti-torsion-braid-cable","tag-bucket-wheel-excavator-cable","tag-bulk-material-handling","tag-cable-bending-radius","tag-class-5-conductor","tag-cold-resistant-mining-cable","tag-copper-weight-4560-kg-km","tag-crane-power-cable","tag-current-capacity-399a","tag-din-vde-0250","tag-dynamic-flexing-cable","tag-dynamic-mechanical-stress","tag-epr-insulated-cable","tag-explosion-proof-mining-cable","tag-festoon-system-cable","tag-flame-retardant-cable","tag-flexible-power-cable","tag-heavy-duty-mining-cable","tag-heavy-duty-reeling-cable-2","tag-heavy-duty-e-loader-mining-cable","tag-high-ampacity-cable","tag-high-tensile-strength-cable","tag-icea-s-75-381-2","tag-iec-60228-class-5","tag-industrial-power-supply","tag-low-temperature-rubber-cable","tag-material-handling-cable","tag-medium-voltage-trailing-cable","tag-mining-cable","tag-mining-cables","tag-mining-machine-cable","tag-mining-power-cable","tag-mobile-mining-equipment","tag-motor-reeling-cable","tag-oil-resistant-cable","tag-open-pit-mining-cable-2","tag-outer-diameter-62mm-68mm","tag-reeling-cable","tag-rubber-sheathed-cable","tag-ship-unloader-cable","tag-short-circuit-current-rating","tag-special-reeling-cable","tag-split-earth-conductor","tag-sts-crane-cable","tag-substation-feeder-cable","tag-substation-power-cable","tag-tinned-copper-conductor","tag-torsion-resistant-cable","tag-trailing-cable-replacement","tag-uv-resistant-cable","tag-vde-0250-813-standard","tag-vfd-symmetrical-cable","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/7549","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=7549"}],"version-history":[{"count":2,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/7549\/revisions"}],"predecessor-version":[{"id":7569,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/7549\/revisions\/7569"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/7550"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=7549"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=7549"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=7549"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}