{"id":6663,"date":"2026-02-09T17:27:35","date_gmt":"2026-02-09T09:27:35","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=6663"},"modified":"2026-02-09T17:27:38","modified_gmt":"2026-02-09T09:27:38","slug":"tenax-lumen-ntscgeh3s-what-does-each-letter-in-the-code-stand-for","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/tenax-lumen-ntscgeh3s-what-does-each-letter-in-the-code-stand-for\/","title":{"rendered":"TENAX-LUMEN\u00a0(N)TSCGEH3S\u00a0\u2014 What Does Each Letter in the Code Stand For?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">How the &#8220;H3&#8221; Suffix Indicates an Integrated Optical \/ Illuminating Element in a Hybrid Reeling Cable<br>\u300cH3\u300d\u540e\u7f00\u5982\u4f55\u8868\u793a\u5377\u7b52\u6df7\u5408\u7535\u7f06\u4e2d\u7684\u96c6\u6210\u5149\u7ea4\/\u7167\u660e\u5143\u4ef6<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img data-dominant-color=\"755b59\" data-has-transparency=\"false\" loading=\"lazy\" decoding=\"async\" width=\"393\" height=\"628\" sizes=\"auto, (max-width: 393px) 100vw, 393px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-784-393x628.avif\" alt=\"\" class=\"wp-image-6664 not-transparent\" style=\"--dominant-color: #755b59; width:640px;height:auto\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-784-393x628.avif 393w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-784-188x300.avif 188w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-784-400x640.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-784.avif 544w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width,initial-scale=1.0\">\n<title>TENAX-LUMEN (N)TSCGEH3S Cable Code Breakdown | Anhui Feichun Special Cable Co., Ltd.<\/title>\n<meta name=\"description\" content=\"Technical analysis of the TENAX-LUMEN (N)TSCGEH3S cable designation code. Learn what each letter stands for and how H3 indicates the integrated optical\/illuminating element. By Anhui Feichun Special Cable.\">\n<meta name=\"keywords\" content=\"(N)TSCGEH3S, TENAX-LUMEN, hybrid cable, optical fiber cable, DIN VDE 0250, reeling cable, Feichun cable, H3 illumination element, EPR insulation, mining cable, crane cable\">\n<style>\n*,*::before,*::after{box-sizing:border-box;margin:0;padding:0}\n:root{\n--bg:#ffffff;--bg2:#f4f5f7;--bg3:#e8eaed;--bg4:#dde0e4;\n--tx:#1a1a2e;--tx2:#3a3a4e;--tx3:#5f6378;\n--accent:#0e4a8a;--accent2:#1a6fcc;--accent-light:#e8f0fe;\n--border:#d0d4dc;--border2:#b8bcc6;\n--tbl-head:#0e4a8a;--tbl-head-tx:#ffffff;--tbl-alt:#f0f4f8;\n--red:#c0392b;--green:#1e7e34;--orange:#d68a00;\n--card-shadow:0 1px 3px rgba(0,0,0,0.08);\n--radius:4px;\n--font-sans:'Segoe UI',Roboto,'Helvetica Neue',Arial,sans-serif;\n--font-mono:'SF Mono','Cascadia Code','Consolas',monospace;\n}\n@media(prefers-color-scheme:dark){\n:root{\n--bg:#121218;--bg2:#1a1a24;--bg3:#24243a;--bg4:#2e2e44;\n--tx:#e0e0ec;--tx2:#b8b8cc;--tx3:#8888a0;\n--accent:#5b9cf5;--accent2:#7bb4ff;--accent-light:#1a2a44;\n--border:#2e2e44;--border2:#3e3e58;\n--tbl-head:#1a3a6a;--tbl-head-tx:#e0e8f8;--tbl-alt:#1a1a28;\n--red:#e74c3c;--green:#2ecc71;--orange:#f1c40f;\n--card-shadow:0 1px 4px rgba(0,0,0,0.3);\n}\n}\nhtml{font-size:16px;scroll-behavior:smooth}\nbody{font-family:var(--font-sans);background:var(--bg);color:var(--tx);line-height:1.72;-webkit-font-smoothing:antialiased}\n.wrapper{max-width:920px;margin:0 auto;padding:24px 20px 60px}\nheader.hero{border-bottom:3px solid var(--accent);padding-bottom:20px;margin-bottom:32px}\n.brand{font-size:.85rem;color:var(--accent);font-weight:600;letter-spacing:.5px;text-transform:uppercase;margin-bottom:2px}\n.brand-cn{font-size:.78rem;color:var(--tx3);margin-bottom:12px}\nh1{font-size:1.55rem;line-height:1.35;color:var(--tx);font-weight:700;margin-bottom:6px}\nh1 .hl{color:var(--accent)}\n.subtitle{font-size:.92rem;color:var(--tx2);margin-bottom:8px}\n.meta{font-size:.78rem;color:var(--tx3)}\n.meta a{color:var(--accent2);text-decoration:none}\nh2{font-size:1.2rem;font-weight:700;color:var(--accent);margin:36px 0 14px;padding-bottom:6px;border-bottom:2px solid var(--border)}\nh3{font-size:1.05rem;font-weight:600;color:var(--tx);margin:24px 0 10px}\np{margin-bottom:14px;color:var(--tx2)}\na{color:var(--accent2)}\nstrong{color:var(--tx);font-weight:600}\n.code-block{display:block;background:var(--bg3);border:1px solid var(--border);border-radius:var(--radius);padding:14px 18px;margin:16px 0;font-family:var(--font-mono);font-size:1.05rem;letter-spacing:1.2px;text-align:center;color:var(--tx);overflow-x:auto;word-break:break-all}\n.code-block .seg{display:inline;cursor:default}\n.c-n{color:var(--red);font-weight:700}\n.c-t{color:#7c3aed;font-weight:700}\n.c-s{color:var(--green);font-weight:700}\n.c-c{color:#d97706;font-weight:700}\n.c-g{color:#059669;font-weight:700}\n.c-e{color:#0891b2;font-weight:700}\n.c-h3{color:var(--red);font-weight:700;text-decoration:underline;text-decoration-style:double}\n.c-s2{color:#7c3aed;font-weight:700}\ntable{width:100%;border-collapse:collapse;margin:18px 0;font-size:.88rem}\nthead th{background:var(--tbl-head);color:var(--tbl-head-tx);padding:10px 14px;text-align:left;font-weight:600;white-space:nowrap}\ntbody td{padding:9px 14px;border-bottom:1px solid var(--border);vertical-align:top}\ntbody tr:nth-child(even){background:var(--tbl-alt)}\ntbody tr:hover{background:var(--accent-light)}\ntd.code-cell{font-family:var(--font-mono);font-weight:700;white-space:nowrap;width:70px;text-align:center}\ntd .cn{display:block;font-size:.8rem;color:var(--tx3);margin-top:2px}\n.note-box{background:var(--accent-light);border-left:4px solid var(--accent);padding:14px 18px;margin:20px 0;border-radius:0 var(--radius) var(--radius) 0;font-size:.88rem}\n.note-box strong{color:var(--accent)}\n.param-grid{display:grid;grid-template-columns:1fr 1fr;gap:12px;margin:18px 0}\n@media(max-width:600px){.param-grid{grid-template-columns:1fr}}\n.param-card{background:var(--bg2);border:1px solid var(--border);border-radius:var(--radius);padding:12px 14px}\n.param-card .label{font-size:.75rem;text-transform:uppercase;letter-spacing:.5px;color:var(--tx3);margin-bottom:2px}\n.param-card .val{font-size:1rem;font-weight:700;color:var(--tx)}\n.param-card .val-note{font-size:.78rem;color:var(--tx3);margin-top:1px}\n.compare-tbl thead th:first-child{width:40%}\n.source-list{margin:18px 0;font-size:.82rem}\n.source-list li{margin-bottom:6px;color:var(--tx3);list-style:decimal inside}\n.source-list a{color:var(--accent2);word-break:break-all}\n.contact-bar{background:var(--bg2);border:1px solid var(--border);border-radius:var(--radius);padding:18px 20px;margin:28px 0}\n.contact-bar p{margin-bottom:8px;font-size:.88rem}\n.contact-bar .wa{display:inline-block;background:#25d366;color:#fff;padding:5px 14px;border-radius:var(--radius);text-decoration:none;font-size:.85rem;font-weight:600;margin-top:4px}\nfooter{border-top:2px solid var(--border);padding-top:16px;margin-top:40px;font-size:.78rem;color:var(--tx3);text-align:center}\nfooter a{color:var(--accent2);text-decoration:none}\n.toc{background:var(--bg2);border:1px solid var(--border);border-radius:var(--radius);padding:16px 20px;margin-bottom:30px}\n.toc-title{font-size:.82rem;font-weight:700;text-transform:uppercase;letter-spacing:.5px;color:var(--tx3);margin-bottom:8px}\n.toc ol{padding-left:18px;font-size:.88rem}\n.toc li{margin-bottom:4px}\n.toc a{color:var(--accent2);text-decoration:none}\n.toc a:hover{text-decoration:underline}\n.badge{display:inline-block;font-size:.7rem;padding:2px 7px;border-radius:3px;font-weight:600;vertical-align:middle;margin-left:4px}\n.badge-key{background:var(--red);color:#fff}\n<\/style>\n<\/head>\n<body>\n<div class=\"wrapper\">\n\n<!-- HEADER -->\n<header class=\"hero\">\n<div class=\"brand\">Anhui Feichun Special Cable Co., Ltd.<\/div>\n<div class=\"brand-cn\">\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/div>\n<h1>TENAX-LUMEN <span class=\"hl\">(N)TSCGEH3S<\/span> \u2014 What Does Each Letter in the Code Stand For?<\/h1>\n<p class=\"subtitle\">How the &#8220;H3&#8221; Suffix Indicates an Integrated Optical \/ Illuminating Element in a Hybrid Reeling Cable<br>\n<span style=\"font-size:.82rem;color:var(--tx3)\">\u300cH3\u300d\u540e\u7f00\u5982\u4f55\u8868\u793a\u5377\u7b52\u6df7\u5408\u7535\u7f06\u4e2d\u7684\u96c6\u6210\u5149\u7ea4\/\u7167\u660e\u5143\u4ef6<\/span><\/p>\n<p class=\"meta\">Published by <strong>Feichun Engineering \u98de\u7eaf\u5de5\u7a0b\u90e8<\/strong>&nbsp;&middot;&nbsp;Cable Design &amp; Application Division&nbsp;&middot;&nbsp;2025<\/p>\n<\/header>\n\n<!-- TABLE OF CONTENTS -->\n<nav class=\"toc\">\n<div class=\"toc-title\">Contents \u76ee\u5f55<\/div>\n<ol>\n<li><a href=\"#intro\">Introduction \u2014 Why Cable Designation Codes Matter &nbsp;\u5f15\u8a00<\/a><\/li>\n<li><a href=\"#decode\">Full Breakdown of (N)TSCGEH3S &nbsp;\u5b8c\u6574\u4ee3\u7801\u62c6\u89e3<\/a><\/li>\n<li><a href=\"#h3\">Deep Dive: What &#8220;H3&#8221; Means \u2014 Optical &amp; Illumination Integration &nbsp;H3 \u6df1\u5ea6\u89e3\u6790<\/a><\/li>\n<li><a href=\"#params\">Key Technical Parameters &nbsp;\u5173\u952e\u6280\u672f\u53c2\u6570<\/a><\/li>\n<li><a href=\"#compare\">Comparison: (N)TSCGEH3S vs. Related Designations &nbsp;\u578b\u53f7\u5bf9\u6bd4<\/a><\/li>\n<li><a href=\"#standards\">Applicable Standards &amp; Certifications &nbsp;\u9002\u7528\u6807\u51c6<\/a><\/li>\n<li><a href=\"#apps\">Target Applications &amp; Machinery &nbsp;\u5e94\u7528\u573a\u666f<\/a><\/li>\n<li><a href=\"#refs\">References &amp; Sources &nbsp;\u53c2\u8003\u6765\u6e90<\/a><\/li>\n<li><a href=\"#contact\">Contact Feichun &nbsp;\u8054\u7cfb\u98de\u7eaf<\/a><\/li>\n<\/ol>\n<\/nav>\n\n<!-- 1. INTRO -->\n<section id=\"intro\">\n<h2>1. Introduction \u2014 Why Cable Designation Codes Matter<span style=\"font-size:.82rem;color:var(--tx3);font-weight:400;margin-left:8px\">\u5f15\u8a00 \u2014 \u4e3a\u4ec0\u4e48\u7535\u7f06\u578b\u53f7\u7f16\u7801\u5982\u6b64\u91cd\u8981<\/span><\/h2>\n\n<p>In the German DIN VDE cable designation system \u2014 widely considered the most comprehensive national nomenclature for industrial cables in the world \u2014 every letter and number encodes a specific material, construction feature, or functional characteristic. This convention, governed by standards such as <strong>DIN VDE 0292<\/strong> (Type Designation Codes) and <strong>DIN VDE 0250 Part 813<\/strong> (flexible reeling and trailing cables), allows an engineer to identify a cable&#8217;s conductor type, insulation, screening, protective earth, sheath, and special integrations simply by reading its alphanumeric type code.<\/p>\n<p style=\"font-size:.86rem;color:var(--tx3)\">\u5728\u5fb7\u56fd DIN VDE \u7535\u7f06\u547d\u540d\u4f53\u7cfb\u4e2d\u2014\u2014\u88ab\u516c\u8ba4\u4e3a\u5168\u7403\u5de5\u4e1a\u7535\u7f06\u9886\u57df\u6700\u5b8c\u5584\u7684\u56fd\u5bb6\u7ea7\u547d\u540d\u89c4\u8303\u2014\u2014\u6bcf\u4e00\u4e2a\u5b57\u6bcd\u548c\u6570\u5b57\u90fd\u7f16\u7801\u4e86\u7279\u5b9a\u7684\u6750\u6599\u3001\u7ed3\u6784\u7279\u5f81\u6216\u529f\u80fd\u5c5e\u6027\u3002\u8be5\u4f53\u7cfb\u7531 DIN VDE 0292\uff08\u578b\u53f7\u4ee3\u7801\u6807\u51c6\uff09\u548c DIN VDE 0250 \u7b2c 813 \u90e8\u5206\uff08\u67d4\u6027\u5377\u7b52\u4e0e\u62d6\u66f3\u7535\u7f06\uff09\u7b49\u6807\u51c6\u7edf\u4e00\u7ba1\u7406\u3002<\/p>\n\n<p>The TENAX-LUMEN <strong>(N)TSCGEH3S<\/strong> designation created by Anhui Feichun Special Cable Co., Ltd. follows this established framework while introducing the proprietary <strong>&#8220;H3&#8221;<\/strong> suffix to denote an integrated optical-fiber and illumination element \u2014 a hybrid design that merges high-power electrical conductors with light-guide fibers within a single cable assembly. This article decodes every segment of the (N)TSCGEH3S designation, with particular focus on the meaning and engineering rationale behind H3.<\/p>\n<p style=\"font-size:.86rem;color:var(--tx3)\">\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8\u5f00\u53d1\u7684 TENAX-LUMEN <strong>(N)TSCGEH3S<\/strong> \u578b\u53f7\u9075\u5faa\u4e0a\u8ff0\u6210\u719f\u6846\u67b6\uff0c\u540c\u65f6\u5f15\u5165\u4e13\u6709\u7684 <strong>&#8220;H3&#8221;<\/strong> \u540e\u7f00\uff0c\u7528\u4e8e\u8868\u793a\u96c6\u6210\u5149\u7ea4\/\u7167\u660e\u5143\u4ef6\u2014\u2014\u4e00\u79cd\u5c06\u5927\u529f\u7387\u7535\u529b\u5bfc\u4f53\u4e0e\u5bfc\u5149\u7ea4\u7ef4\u5408\u4e3a\u4e00\u4f53\u7684\u6df7\u5408\u8bbe\u8ba1\u3002<\/p>\n<\/section>\n\n<!-- 2. FULL BREAKDOWN -->\n<section id=\"decode\">\n<h2>2. Full Code Breakdown of (N)TSCGEH3S<span style=\"font-size:.82rem;color:var(--tx3);font-weight:400;margin-left:8px\">\u5b8c\u6574\u4ee3\u7801\u62c6\u89e3<\/span><\/h2>\n\n<div class=\"code-block\">\n<span class=\"seg c-n\">(N)<\/span><span class=\"seg c-t\">T<\/span><span class=\"seg c-s\">S<\/span><span class=\"seg c-c\">C<\/span><span class=\"seg c-g\">G<\/span><span class=\"seg c-e\">E<\/span><span class=\"seg c-h3\">H3<\/span><span class=\"seg c-s2\">S<\/span>\n<\/div>\n\n<table>\n<thead>\n<tr><th>Position<\/th><th>Code<\/th><th>Meaning (English)<\/th><th>\u542b\u4e49 (Chinese)<\/th><th>DIN VDE Basis<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td class=\"code-cell\" style=\"color:var(--red)\">(N)<\/td>\n<td><strong>National-standard construction.<\/strong> Parentheses indicate that the cable is designed in accordance with the DIN VDE system but has not been independently VDE-certified\/registered. Without parentheses, &#8220;N&#8221; would mean a fully VDE-registered type.<\/td>\n<td>\u6309\u56fd\u5bb6\uff08DIN VDE\uff09\u6807\u51c6\u8bbe\u8ba1\uff1b\u62ec\u53f7\u8868\u793a\u8bbe\u8ba1\u7b26\u5408\u6807\u51c6\u4f46\u5c1a\u672a\u83b7\u5f97 VDE \u72ec\u7acb\u8ba4\u8bc1\u3002<span class=\"cn\"><\/span><\/td>\n<td>DIN VDE 0292 \u00a74<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td class=\"code-cell\" style=\"color:#7c3aed\">T<\/td>\n<td><strong>Textile braiding (Textilumflechtung).<\/strong> A woven textile serving layer applied over the core assembly provides mechanical abrasion protection and serves as a bedding layer between the core bundle and the outer metallic screen. This is a hallmark of heavy-duty reeling cables designed for repeated flexing.<\/td>\n<td>\u7eba\u7ec7\u7f16\u7ec7\u5c42\uff08Textilumflechtung\uff09\u3002\u7f20\u7ed5\u5728\u7ebf\u82af\u7ec4\u5408\u5916\u7684\u7f16\u7ec7\u7ec7\u7269\u5c42\uff0c\u63d0\u4f9b\u673a\u68b0\u8010\u78e8\u4fdd\u62a4\u3002<span class=\"cn\"><\/span><\/td>\n<td>DIN VDE 0250-813; SAB Br\u00f6ckskes designation table<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td class=\"code-cell\" style=\"color:var(--green)\">S<\/td>\n<td><strong>Steel-wire braiding (Stahlgeflecht).<\/strong> A braided steel-wire armor layer provides tensile-load bearing capacity and protects the cable against crush and impact. In reeling-cable applications this layer absorbs the significant dynamic tensile forces encountered during acceleration, deceleration, and multi-directional bending.<\/td>\n<td>\u94a2\u4e1d\u7f16\u7ec7\u94e0\u88c5\u5c42\uff08Stahlgeflecht\uff09\u3002\u63d0\u4f9b\u6297\u62c9\u627f\u8f7d\u80fd\u529b\uff0c\u4fdd\u62a4\u7535\u7f06\u514d\u53d7\u78be\u538b\u548c\u51b2\u51fb\u3002<span class=\"cn\"><\/span><\/td>\n<td>DIN VDE 0250-813; DIN VDE 0298 Part 3<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td class=\"code-cell\" style=\"color:#d97706\">C<\/td>\n<td><strong>Copper-wire braiding (Kupfergeflecht).<\/strong> An electromagnetic shield (EMC screen) formed by a tinned or bare copper braid. Provides EMI\/RFI screening for the power conductors and, critically, protects the sensitive optical fibers from electromagnetic interference.<\/td>\n<td>\u94dc\u4e1d\u7f16\u7ec7\u5c4f\u853d\u5c42\uff08Kupfergeflecht\uff09\u3002\u7531\u9540\u9521\u6216\u88f8\u94dc\u7f16\u7ec7\u5c42\u6784\u6210\u7684\u7535\u78c1\u5c4f\u853d\uff08EMC \u5c4f\u853d\uff09\uff0c\u4fdd\u62a4\u5149\u7ea4\u514d\u53d7\u7535\u78c1\u5e72\u6270\u3002<span class=\"cn\"><\/span><\/td>\n<td>DIN VDE 0250-813; IEC 60092-350 (EMC)<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td class=\"code-cell\" style=\"color:#059669\">G<\/td>\n<td><strong>Green-yellow protective earth conductor (Gr\u00fcn-gelb Schutzleiter).<\/strong> The cable contains a dedicated protective earth (PE) conductor identified by the internationally standardised green\/yellow colour marking, ensuring personnel safety through proper earthing.<\/td>\n<td>\u9ec4\u7eff\u8272\u4fdd\u62a4\u63a5\u5730\u5bfc\u4f53\uff08Gr\u00fcn-gelb Schutzleiter\uff09\u3002\u7535\u7f06\u5185\u542b\u4e13\u7528 PE \u4fdd\u62a4\u63a5\u5730\u7ebf\u3002<span class=\"cn\"><\/span><\/td>\n<td>DIN VDE 0293-308; IEC 60446<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td class=\"code-cell\" style=\"color:#0891b2\">E<\/td>\n<td><strong>EPR (Ethylene Propylene Rubber) insulation.<\/strong> In the DIN VDE 0250-813 family, &#8220;E&#8221; denotes EPR-based insulation on the power conductors \u2014 a high-performance elastomer offering excellent thermal endurance (rated 90 \u00b0C continuous, 250 \u00b0C short-circuit), outstanding flexibility, and superior resistance to ozone, UV, and weathering.<\/td>\n<td>EPR\uff08\u4e59\u4e19\u6a61\u80f6\uff09\u7edd\u7f18\u3002\u5728 DIN VDE 0250-813 \u7cfb\u5217\u4e2d\uff0c&#8221;E&#8221;\u4ee3\u8868 EPR \u7edd\u7f18\u2014\u2014\u4e00\u79cd\u9ad8\u6027\u80fd\u5f39\u6027\u4f53\uff0c\u5177\u5907\u51fa\u8272\u7684\u8010\u70ed\u6027\uff08\u989d\u5b9a 90\u00b0C \u8fde\u7eed\u3001250\u00b0C \u77ed\u8def\uff09\u548c\u67d4\u97e7\u6027\u3002<span class=\"cn\"><\/span><\/td>\n<td>DIN VDE 0250-813; IEC 60502<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td class=\"code-cell\" style=\"color:var(--red);text-decoration:underline double\">H3 <span class=\"badge badge-key\">KEY<\/span><\/td>\n<td><strong>Integrated Optical \/ Illuminating Element (Hybrid Lichtleiter-Element).<\/strong> The &#8220;H&#8221; prefix in DIN VDE designations indicates a special constructional variant (H = flat divisible, H2 = flat non-divisible, H6 = elevator flat, H8 = helix). <strong>&#8220;H3&#8221; is Feichun&#8217;s proprietary extension<\/strong> designating a hybrid optical-fiber and illumination integration \u2014 the cable embeds fiber-optic light-guides capable of transmitting both data signals AND visible-spectrum illumination light alongside the primary power conductors. This is the defining innovation of the TENAX-LUMEN range. <em>See Section 3 for full technical detail.<\/em><\/td>\n<td><strong>\u96c6\u6210\u5149\u7ea4\/\u7167\u660e\u5143\u4ef6\uff08\u6df7\u5408\u5149\u5bfc\u5143\u4ef6\uff09\u3002<\/strong>DIN VDE \u547d\u540d\u4f53\u7cfb\u4e2d &#8220;H&#8221; \u524d\u7f00\u8868\u793a\u7279\u6b8a\u7ed3\u6784\u53d8\u4f53\u3002<strong>&#8220;H3&#8243;\u662f\u98de\u7eaf\u7684\u4e13\u6709\u6269\u5c55\u6807\u8bc6<\/strong>\uff0c\u8868\u793a\u6df7\u5408\u5149\u7ea4\u4e0e\u7167\u660e\u96c6\u6210\u2014\u2014\u7535\u7f06\u5d4c\u5165\u53ef\u540c\u65f6\u4f20\u8f93\u6570\u636e\u4fe1\u53f7\u548c\u53ef\u89c1\u5149\u7167\u660e\u7684\u5149\u5bfc\u7ea4\u7ef4\u3002\u8fd9\u662f TENAX-LUMEN \u7cfb\u5217\u7684\u6838\u5fc3\u521b\u65b0\u3002<span class=\"cn\"><\/span><\/td>\n<td>Based on DIN VDE 0292 H-suffix convention; Feichun proprietary extension<\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td class=\"code-cell\" style=\"color:#7c3aed\">S<\/td>\n<td><strong>Silicone-rubber or special elastomer outer sheath.<\/strong> In the trailing position of DIN VDE type codes, &#8220;S&#8221; denotes a silicone-based or specially compounded outer sheath providing extreme temperature range, flame retardancy, and halogen-free combustion performance. Alternatives in the same position (e.g. &#8220;W&#8221; = weather-resistant polychloroprene, &#8220;O&#8221; = oil-resistant) serve different environmental requirements.<\/td>\n<td>\u7845\u6a61\u80f6\u6216\u7279\u79cd\u5f39\u6027\u4f53\u5916\u62a4\u5957\u3002\u5728 DIN VDE \u578b\u53f7\u4ee3\u7801\u7684\u672b\u4f4d\uff0c&#8221;S&#8221;\u8868\u793a\u7845\u80f6\u57fa\u5916\u62a4\u5957\uff0c\u63d0\u4f9b\u6781\u7aef\u6e29\u5ea6\u8303\u56f4\u3001\u963b\u71c3\u6027\u548c\u65e0\u5364\u71c3\u70e7\u6027\u80fd\u3002<span class=\"cn\"><\/span><\/td>\n<td>DIN VDE 0282; SAB designation system<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n\n<!-- 3. H3 DEEP DIVE -->\n<section id=\"h3\">\n<h2>3. Deep Dive \u2014 What &#8220;H3&#8221; Means: Optical &amp; Illumination Integration <span class=\"badge badge-key\">CORE TOPIC<\/span><span style=\"font-size:.82rem;color:var(--tx3);font-weight:400;margin-left:8px\">H3 \u6df1\u5ea6\u89e3\u6790<\/span><\/h2>\n\n<h3>3.1 The &#8220;H&#8221; Suffix Family in DIN VDE (DIN VDE \u4f53\u7cfb\u4e2d\u7684&#8221;H&#8221;\u540e\u7f00\u7cfb\u5217)<\/h3>\n<p>Within the harmonised and DIN VDE cable designation systems, the &#8220;H&#8221; character (with an appended numeral) traditionally encodes special geometric or constructional cable forms. For reference, the established designations from the SAB Br\u00f6ckskes \/ DIN VDE 0292 framework are as follows: <strong>H<\/strong> = divisible flat cable, <strong>H2<\/strong> = non-divisible flat cable, <strong>H6<\/strong> = non-divisible flat cable for elevators, and <strong>H8<\/strong> = helix (coiled) cable. These H-codes have been standardised for decades and are universally recognised across European cable manufacturing.<\/p>\n<p style=\"font-size:.86rem;color:var(--tx3)\">\u5728\u534f\u8c03\u548c DIN VDE \u7535\u7f06\u547d\u540d\u4f53\u7cfb\u4e2d\uff0c&#8221;H&#8221;\u5b57\u7b26\uff08\u9644\u52a0\u6570\u5b57\uff09\u4f20\u7edf\u4e0a\u7f16\u7801\u7279\u6b8a\u7684\u51e0\u4f55\u6216\u7ed3\u6784\u7535\u7f06\u5f62\u5f0f\u3002\u6807\u51c6\u5b9a\u4e49\uff1aH = \u53ef\u5206\u79bb\u6241\u5e73\u7535\u7f06\uff0cH2 = \u4e0d\u53ef\u5206\u79bb\u6241\u5e73\u7535\u7f06\uff0cH6 = \u7535\u68af\u4e13\u7528\u6241\u5e73\u7535\u7f06\uff0cH8 = \u87ba\u65cb\uff08\u76d8\u7ed5\uff09\u7535\u7f06\u3002<\/p>\n\n<h3>3.2 H3 \u2014 Feichun&#8217;s Extension: Hybrid Light-Guide Element (\u98de\u7eaf\u7684\u6269\u5c55\u5b9a\u4e49\uff1a\u6df7\u5408\u5bfc\u5149\u5143\u4ef6)<\/h3>\n<p>The <strong>&#8220;H3&#8221;<\/strong> designation in (N)TSCGEH3S is a proprietary designation developed by Anhui Feichun Special Cable Co., Ltd. to fill a nomenclature gap. While existing H-codes (H, H2, H6, H8) address cable geometry, no standardised code specifically addressed the integration of optical fiber used simultaneously for data transmission and visible-spectrum illumination within a power-carrying cable. The &#8220;H3&#8221; code provides this distinction and conveys three integrated functions in one hybrid element.<\/p>\n\n<p><strong>Function \u2460: Power Transmission (\u7535\u529b\u4f20\u8f93)<\/strong> \u2014 The primary copper conductors with EPR insulation carry the main electrical load at rated voltages from 0.6\/1 kV up to medium-voltage levels (e.g. 3.6\/6 kV, 6\/10 kV depending on configuration).<\/p>\n\n<p><strong>Function \u2461: Optical Data Communication (\u5149\u7ea4\u6570\u636e\u901a\u4fe1)<\/strong> \u2014 Multimode or single-mode fiber-optic elements integrated into the cable core carry high-bandwidth control signals, sensor data, and diagnostics \u2014 analogous to the &#8220;LWL&#8221; (Lichtwellenleiter, German for optical waveguide) fiber integration seen in Prysmian&#8217;s PROTOLON (N)TSKCGEWOEU reeling cables with integrated fibre optics.<\/p>\n\n<p><strong>Function \u2462: Visible-Spectrum Illumination (\u53ef\u89c1\u5149\u7167\u660e)<\/strong> \u2014 This is what distinguishes H3 from a standard fiber-optic hybrid (which would typically use a &#8220;K&#8221; or &#8220;LWL&#8221; suffix). The &#8220;LUMEN&#8221; in TENAX-LUMEN signals that the fiber-optic elements are engineered to also carry visible-light illumination, making them suitable for side-emitting or end-emitting lighting functions in environments where cable-integrated illumination is required (e.g. underground mine galleries, crane booms at night, or stage-rigging applications where the cable itself provides pathway lighting).<\/p>\n<p style=\"font-size:.86rem;color:var(--tx3)\">\u8fd9\u6b63\u662f H3 \u533a\u522b\u4e8e\u6807\u51c6\u5149\u7ea4\u6df7\u5408\uff08\u901a\u5e38\u4f7f\u7528&#8221;K&#8221;\u6216&#8221;LWL&#8221;\u540e\u7f00\uff09\u7684\u5173\u952e\u3002TENAX-LUMEN \u4e2d\u7684&#8221;LUMEN&#8221;\u8868\u793a\u5149\u7ea4\u5143\u4ef6\u8fd8\u53ef\u627f\u8f7d\u53ef\u89c1\u5149\u7167\u660e\u529f\u80fd\uff0c\u9002\u7528\u4e8e\u9700\u8981\u7535\u7f06\u96c6\u6210\u7167\u660e\u7684\u73af\u5883\uff08\u5982\u5730\u4e0b\u77ff\u4e95\u5df7\u9053\u3001\u591c\u95f4\u8d77\u91cd\u673a\u81c2\u67b6\u3001\u6216\u821e\u53f0\u7d22\u5177\u7167\u660e\uff09\u3002<\/p>\n\n<div class=\"note-box\">\n<strong>Engineering Note \u5de5\u7a0b\u5907\u6ce8:<\/strong> The &#8220;3&#8221; in H3 can be understood as encoding the three-fold integration: (1) electrical power, (2) optical data, and (3) optical illumination. This &#8220;triple-service&#8221; design is reflected in the product brand name &#8220;TENAX&#8221; (Latin: tenacious \/ holding firmly \u2014 referencing mechanical robustness) + &#8220;LUMEN&#8221; (Latin: light \u2014 referencing the illumination capability).\n<\/div>\n\n<h3>3.3 Fiber Specification within the H3 Element (H3 \u5143\u4ef6\u5185\u7684\u5149\u7ea4\u89c4\u683c)<\/h3>\n<table>\n<thead><tr><th>Parameter \u53c2\u6570<\/th><th>Data-Grade Fiber \u6570\u636e\u7ea7\u5149\u7ea4<\/th><th>Illumination Fiber \u7167\u660e\u7ea7\u5149\u7ea4<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Type \u7c7b\u578b<\/td><td>G.652.D Single-mode or 50\/125 \u03bcm OM3 Multimode<\/td><td>Large-core PMMA or silica side-emitting fiber<\/td><\/tr>\n<tr><td>Core diameter \u82af\u5f84<\/td><td>9 \u03bcm (SM) \/ 50 \u03bcm (MM)<\/td><td>250\u20131000 \u03bcm<\/td><\/tr>\n<tr><td>Primary function \u4e3b\u8981\u529f\u80fd<\/td><td>SCADA, PLC data, diagnostics<\/td><td>Visible-light pathway illumination<\/td><\/tr>\n<tr><td>Wavelength \u6ce2\u957f<\/td><td>1310\/1550 nm (SM) or 850\/1300 nm (MM)<\/td><td>400\u2013700 nm (visible spectrum)<\/td><\/tr>\n<tr><td>Relevant standard \u76f8\u5173\u6807\u51c6<\/td><td>ITU-T G.652; IEC 60793<\/td><td>IEC 60793-2-40 (A4f fibers)<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n\n<!-- 4. KEY PARAMETERS -->\n<section id=\"params\">\n<h2>4. Key Technical Parameters<span style=\"font-size:.82rem;color:var(--tx3);font-weight:400;margin-left:8px\">\u5173\u952e\u6280\u672f\u53c2\u6570<\/span><\/h2>\n<div class=\"param-grid\">\n<div class=\"param-card\">\n<div class=\"label\">Rated Voltage \u989d\u5b9a\u7535\u538b<\/div>\n<div class=\"val\">0.6\/1 kV \u2014 6\/10 kV<\/div>\n<div class=\"val-note\">Configurable per application class<\/div>\n<\/div>\n<div class=\"param-card\">\n<div class=\"label\">Max. Conductor Temp. \u6700\u9ad8\u5bfc\u4f53\u6e29\u5ea6<\/div>\n<div class=\"val\">90 \u00b0C (continuous)<\/div>\n<div class=\"val-note\">250 \u00b0C short-circuit per DIN VDE 0298<\/div>\n<\/div>\n<div class=\"param-card\">\n<div class=\"label\">Ambient Temp. Range \u73af\u5883\u6e29\u5ea6\u8303\u56f4<\/div>\n<div class=\"val\">\u221240 \u00b0C to +80 \u00b0C<\/div>\n<div class=\"val-note\">Flexible operation from \u221235 \u00b0C<\/div>\n<\/div>\n<div class=\"param-card\">\n<div class=\"label\">Insulation \u7edd\u7f18<\/div>\n<div class=\"val\">EPR (Ethylene Propylene Rubber)<\/div>\n<div class=\"val-note\">Per IEC 60502 \/ DIN VDE 0250-813<\/div>\n<\/div>\n<div class=\"param-card\">\n<div class=\"label\">Outer Sheath \u5916\u62a4\u5957<\/div>\n<div class=\"val\">Special Silicone Elastomer (S)<\/div>\n<div class=\"val-note\">Halogen-free, flame retardant<\/div>\n<\/div>\n<div class=\"param-card\">\n<div class=\"label\">Screening \u5c4f\u853d<\/div>\n<div class=\"val\">Steel braid + Copper braid (S+C)<\/div>\n<div class=\"val-note\">Dual-layer EMC protection<\/div>\n<\/div>\n<div class=\"param-card\">\n<div class=\"label\">Max. Tensile Load \u6700\u5927\u6297\u62c9\u8d1f\u8377<\/div>\n<div class=\"val\">Up to 30 N\/mm\u00b2<\/div>\n<div class=\"val-note\">Per DIN VDE 0298 Part 3 (15 N\/mm\u00b2 std.)<\/div>\n<\/div>\n<div class=\"param-card\">\n<div class=\"label\">Min. Bending Radius \u6700\u5c0f\u5f2f\u66f2\u534a\u5f84<\/div>\n<div class=\"val\">Per DIN VDE 0298 Part 3<\/div>\n<div class=\"val-note\">S-type directional changes: \u2265 20 \u00d7 D<\/div>\n<\/div>\n<\/div>\n<\/section>\n\n<!-- 5. COMPARISON -->\n<section id=\"compare\">\n<h2>5. Designation Comparison Table<span style=\"font-size:.82rem;color:var(--tx3);font-weight:400;margin-left:8px\">\u578b\u53f7\u5bf9\u6bd4\u8868<\/span><\/h2>\n<p>The following table compares the TENAX-LUMEN (N)TSCGEH3S with related industrial reeling-cable designations to highlight the functional scope of each code segment. This helps engineers understand precisely which features the H3 suffix adds relative to existing cable types.<\/p>\n<p style=\"font-size:.86rem;color:var(--tx3)\">\u4e0b\u8868\u5c06 TENAX-LUMEN (N)TSCGEH3S \u4e0e\u76f8\u5173\u5de5\u4e1a\u5377\u7b52\u7535\u7f06\u578b\u53f7\u8fdb\u884c\u5bf9\u6bd4\uff0c\u7a81\u51fa H3 \u540e\u7f00\u76f8\u8f83\u73b0\u6709\u7535\u7f06\u578b\u53f7\u6240\u589e\u52a0\u7684\u529f\u80fd\u3002<\/p>\n\n<table class=\"compare-tbl\">\n<thead>\n<tr>\n<th>Feature \u7279\u5f81<\/th>\n<th>(N)TSCGEWOEU<br><span style=\"font-weight:400;font-size:.75rem\">Prysmian Protolon series<\/span><\/th>\n<th>(N)TSKCGEWOEU<br><span style=\"font-weight:400;font-size:.75rem\">Protolon w\/ Fiber Optics<\/span><\/th>\n<th>(N)TSCGEH3S<br><span style=\"font-weight:400;font-size:.75rem\">Feichun TENAX-LUMEN<\/span><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr><td>Textile braiding (T) \u7eba\u7ec7\u7f16\u7ec7\u5c42<\/td><td>Yes<\/td><td>Yes<\/td><td>Yes<\/td><\/tr>\n<tr><td>Steel-wire braid armor (S) \u94a2\u4e1d\u7f16\u7ec7\u94e0\u88c5<\/td><td>Yes<\/td><td>Yes<\/td><td>Yes<\/td><\/tr>\n<tr><td>Copper EMC screen (C) \u94dc\u7f16\u7ec7\u5c4f\u853d<\/td><td>Yes<\/td><td>Yes (KC = reinforced)<\/td><td>Yes<\/td><\/tr>\n<tr><td>PE conductor (G) \u4fdd\u62a4\u63a5\u5730<\/td><td>Yes<\/td><td>Yes<\/td><td>Yes<\/td><\/tr>\n<tr><td>EPR insulation (E) EPR \u7edd\u7f18<\/td><td>Yes<\/td><td>Yes<\/td><td>Yes<\/td><\/tr>\n<tr><td>Weather-resistant (W) \u8010\u5019<\/td><td>Yes<\/td><td>Yes<\/td><td>Via S-sheath<\/td><\/tr>\n<tr><td>Oil-resistant (O) \u8010\u6cb9<\/td><td>Yes (\u00d6\/OE)<\/td><td>Yes<\/td><td>Optional<\/td><\/tr>\n<tr><td>Outdoor use (EU) \u6237\u5916\u4f7f\u7528<\/td><td>Yes<\/td><td>Yes<\/td><td>Yes<\/td><\/tr>\n<tr><td>Data-grade fiber optics \u6570\u636e\u7ea7\u5149\u7ea4<\/td><td style=\"color:var(--red)\">No<\/td><td style=\"color:var(--green)\">Yes<\/td><td style=\"color:var(--green)\"><strong>Yes<\/strong><\/td><\/tr>\n<tr><td>Illumination fiber (visible light) \u7167\u660e\u5149\u7ea4<\/td><td style=\"color:var(--red)\">No<\/td><td style=\"color:var(--red)\">No<\/td><td style=\"color:var(--green)\"><strong>Yes (H3)<\/strong><\/td><\/tr>\n<tr><td>Silicone outer sheath (S) \u7845\u80f6\u5916\u62a4\u5957<\/td><td>Polychloroprene<\/td><td>Polychloroprene<\/td><td><strong>Silicone elastomer<\/strong><\/td><\/tr>\n<tr><td>Primary standard \u4e3b\u8981\u6807\u51c6<\/td><td>DIN VDE 0250-813<\/td><td>DIN VDE 0250-813<\/td><td>Based on DIN VDE 0250-813<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n\n<!-- 6. STANDARDS -->\n<section id=\"standards\">\n<h2>6. Applicable Standards &amp; Certifications<span style=\"font-size:.82rem;color:var(--tx3);font-weight:400;margin-left:8px\">\u9002\u7528\u6807\u51c6\u4e0e\u8ba4\u8bc1<\/span><\/h2>\n<table>\n<thead><tr><th>Standard \u6807\u51c6<\/th><th>Title \/ Scope \u6807\u9898\/\u8303\u56f4<\/th><th>Relevance to (N)TSCGEH3S<\/th><\/tr><\/thead>\n<tbody>\n<tr><td><strong>DIN VDE 0292<\/strong><\/td><td>System for cable designation (HD 361 S4:2020)<\/td><td>Governs the type-code letter system including H-suffixes<\/td><\/tr>\n<tr><td><strong>DIN VDE 0250-813<\/strong><\/td><td>Flexible cables for reeling and trailing \u2014 heavy duty<\/td><td>Core design standard for NTSCGE-family cables<\/td><\/tr>\n<tr><td><strong>DIN VDE 0298 Part 3<\/strong><\/td><td>Use of cables \u2014 current ratings, tensile loads, bending radii<\/td><td>Defines mechanical limits (30 N\/mm\u00b2, bending radius)<\/td><\/tr>\n<tr><td><strong>DIN VDE 0282<\/strong><\/td><td>Rubber-insulated cables<\/td><td>Silicone sheath (S) material requirements<\/td><\/tr>\n<tr><td><strong>IEC 60502<\/strong><\/td><td>Power cables with extruded insulation 0.6\/1 kV \u2013 30 kV<\/td><td>EPR insulation performance requirements<\/td><\/tr>\n<tr><td><strong>IEC 60793<\/strong><\/td><td>Optical fibres \u2014 specifications and test methods<\/td><td>Fiber-optic elements within the H3 unit<\/td><\/tr>\n<tr><td><strong>ITU-T G.652<\/strong><\/td><td>Characteristics of single-mode optical fibre and cable<\/td><td>Data-grade SM fiber within the H3 element<\/td><\/tr>\n<tr><td><strong>IEC 60332<\/strong><\/td><td>Flame-retardance tests on cables<\/td><td>Fire performance of silicone sheath<\/td><\/tr>\n<tr><td><strong>DIN EN 60811-404<\/strong><\/td><td>Common test methods \u2014 low-temperature tests<\/td><td>Cold-flexibility verification<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n\n<!-- 7. APPLICATIONS -->\n<section id=\"apps\">\n<h2>7. Target Applications &amp; Machinery<span style=\"font-size:.82rem;color:var(--tx3);font-weight:400;margin-left:8px\">\u5e94\u7528\u573a\u666f\u4e0e\u8bbe\u5907<\/span><\/h2>\n<p>The triple-service design of the TENAX-LUMEN (N)TSCGEH3S makes it suitable for demanding environments where power delivery, real-time data communication, and integrated illumination must be combined in a single, mechanically robust cable assembly. The following table summarises typical deployment scenarios.<\/p>\n<p style=\"font-size:.86rem;color:var(--tx3)\">TENAX-LUMEN (N)TSCGEH3S \u7684&#8221;\u4e09\u5408\u4e00&#8221;\u8bbe\u8ba1\u4f7f\u5176\u9002\u7528\u4e8e\u9700\u8981\u5728\u5355\u6839\u673a\u68b0\u5f3a\u5ea6\u9ad8\u7684\u7535\u7f06\u4e2d\u540c\u65f6\u5b9e\u73b0\u4f9b\u7535\u3001\u5b9e\u65f6\u6570\u636e\u901a\u4fe1\u548c\u96c6\u6210\u7167\u660e\u7684\u82db\u523b\u73af\u5883\u3002<\/p>\n\n<table>\n<thead><tr><th>Application Sector \u5e94\u7528\u9886\u57df<\/th><th>Typical Equipment \u5178\u578b\u8bbe\u5907<\/th><th>H3 Benefit (H3 \u4f18\u52bf)<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Port &amp; Container Terminals \u6e2f\u53e3\u548c\u96c6\u88c5\u7bb1\u7801\u5934<\/td><td>Gantry cranes (STS, RTG), spreaders, ship-to-shore cranes<\/td><td>Cable-integrated pathway lighting for night operations; fiber data for crane automation (SPS\/PLC)<\/td><\/tr>\n<tr><td>Open-Pit &amp; Underground Mining \u9732\u5929\u548c\u5730\u4e0b\u91c7\u77ff<\/td><td>Bucket-wheel excavators, spreaders, conveyor stackers<\/td><td>Gallery illumination via cable; fiber-optic SCADA for excavator positioning<\/td><\/tr>\n<tr><td>Stage &amp; Entertainment Rigging \u821e\u53f0\u548c\u5a31\u4e50\u7d22\u5177<\/td><td>Motorised hoists, flying-bar systems, arena roof structures<\/td><td>Architectural lighting effect via side-emitting fibers; DMX-over-fiber control data<\/td><\/tr>\n<tr><td>Offshore &amp; Marine \u6d77\u6d0b\u5de5\u7a0b<\/td><td>Deck cranes, offshore loading arms, FPSO turret systems<\/td><td>Illumination in hazardous zones; fiber eliminates spark risk for data<\/td><\/tr>\n<tr><td>Heavy Industry \/ Steel \u91cd\u5de5\u4e1a\/\u94a2\u94c1<\/td><td>Ladle cranes, coil-handling cranes, slag-pot transporters<\/td><td>High-temperature silicone sheath + integrated fiber diagnostics<\/td><\/tr>\n<tr><td>Tunnelling (TBM) \u96a7\u9053\u6398\u8fdb<\/td><td>Tunnel boring machines, segment erectors<\/td><td>Tunnel-face illumination; real-time TBM sensor data via fiber<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n\n<!-- 8. REFERENCES -->\n<section id=\"refs\">\n<h2>8. References &amp; Sources<span style=\"font-size:.82rem;color:var(--tx3);font-weight:400;margin-left:8px\">\u53c2\u8003\u6765\u6e90<\/span><\/h2>\n<p>The following authoritative sources have been referenced in the preparation of this technical article. External links are provided with <code>rel=\"nofollow\"<\/code> attributes in accordance with web best practices.<\/p>\n\n<ol class=\"source-list\">\n<li><strong>SAB Br\u00f6ckskes GmbH &amp; Co. KG<\/strong> \u2014 &#8220;Types of Cables and Wires: Designations &amp; Abbreviations.&#8221; <a href=\"https:\/\/www.sab-cable.com\/cables-wires-harnessing-temperature-measurement\/technical-data\/cables-and-wires\/types-of-cables-and-wires-abbreviations.html\" rel=\"nofollow noopener\" target=\"_blank\">sab-cable.com<\/a><\/li>\n<li><strong>Bayerische Kabelwerke AG (Bayka)<\/strong> \u2014 &#8220;Type Designation Codes.&#8221; DIN VDE 0292 reference tables. <a href=\"https:\/\/www.bayka.de\/en\/service\/technical-information\/type-designation-codes\/\" rel=\"nofollow noopener\" target=\"_blank\">bayka.de<\/a><\/li>\n<li><strong>Eland Cables<\/strong> \u2014 &#8220;FAQ: What Do Cable Designations Mean?&#8221; DIN VDE and CENELEC nomenclature guide. <a href=\"https:\/\/www.elandcables.com\/the-cable-lab\/faqs\/what-do-cable-designations-mean\" rel=\"nofollow noopener\" target=\"_blank\">elandcables.com<\/a><\/li>\n<li><strong>Stex24 \/ HELUKABEL<\/strong> \u2014 &#8220;Cable Designation: That&#8217;s What the Abbreviations Stand For.&#8221; <a href=\"https:\/\/stex24.com\/guide\/cable-name\" rel=\"nofollow noopener\" target=\"_blank\">stex24.com<\/a><\/li>\n<li><strong>Prysmian Group<\/strong> \u2014 PROTOLON (SMK) (N)TSCGEWOEU technical data sheet. <a href=\"https:\/\/na.prysmian.com\/sites\/na.prysmian.com\/files\/media\/documents\/PROTOLON(SMK)%20(N)TSCGEWOEU.pdf\" rel=\"nofollow noopener\" target=\"_blank\">prysmian.com<\/a><\/li>\n<li><strong>Power &amp; Cables<\/strong> \u2014 &#8220;Protolon Cable (N)TSKCGEWOEU \u2014 MV Flexible Trailing Cables With Integrated Fibre Optics.&#8221; <a href=\"https:\/\/www.powerandcables.com\/product\/product-category\/protolon-cable-ntskcgewoeu\/\" rel=\"nofollow noopener\" target=\"_blank\">powerandcables.com<\/a><\/li>\n<li><strong>Sumcab<\/strong> \u2014 &#8220;Cable Naming Conventions: Do You Know What They Mean?&#8221; <a href=\"https:\/\/sumcab.com\/en\/blog\/cable-naming-conventions-do-you-know-what-they-mean\" rel=\"nofollow noopener\" target=\"_blank\">sumcab.com<\/a><\/li>\n<li><strong>KLZ Cables<\/strong> \u2014 &#8220;Understanding Key Cable Abbreviations.&#8221; <a href=\"https:\/\/klz-cables.com\/cable-abbreviations-decoded-the-key-to-choosing-the-right-cable\/\" rel=\"nofollow noopener\" target=\"_blank\">klz-cables.com<\/a><\/li>\n<li><strong>DIN Media (DKE\/VDE)<\/strong> \u2014 DIN VDE 0292:2021-08 Standard, HD 361 S4:2020. <a href=\"https:\/\/www.dinmedia.de\/en\/standard\/din-vde-0292\/340926121\" rel=\"nofollow noopener\" target=\"_blank\">dinmedia.de<\/a><\/li>\n<li><strong>Feichun Cables<\/strong> \u2014 &#8220;Understanding Cable Standards: IEC vs. DIN VDE vs. BS EN.&#8221; <a href=\"https:\/\/www.cranecable.com.au\/understanding-cable-standards-iec-vs-din-vde-vs-bs-en-a-complete-guide-to-international-cable-regulations-and-compliance\" rel=\"nofollow noopener\" target=\"_blank\">cranecable.com.au<\/a><\/li>\n<li><strong>TME \/ Transfer Multisort Elektronik<\/strong> \u2014 &#8220;Designation of Cables According to Harmonised Standards.&#8221; <a href=\"https:\/\/www.tme.eu\/en\/news\/library-articles\/page\/41461\/designation-of-cables-according-to-harmonised-standards\/\" rel=\"nofollow noopener\" target=\"_blank\">tme.eu<\/a><\/li>\n<li><strong>Tullyn Trading<\/strong> \u2014 &#8220;F-NTSCGEWOU Fiber Optic HV Reeling Cable.&#8221; <a href=\"https:\/\/www.tullyn.com\/product\/f-ntscgewou-high-voltage-fiber-optic-reeling-cable\/\" rel=\"nofollow noopener\" target=\"_blank\">tullyn.com<\/a><\/li>\n<li><strong>Caledonian Cables<\/strong> \u2014 &#8220;(N)TSCGEWOEU MV Reeling Cable With Fiber Optics \u2014 VDE 0250 Part 813.&#8221; <a href=\"https:\/\/www.caledonian-cables.co.uk\/products\/mining-cable\/VDE\/N-TSCGEWOEU-MV-Reeling-Cable-With-Fiber-Optics.shtml\" rel=\"nofollow noopener\" target=\"_blank\">caledonian-cables.co.uk<\/a><\/li>\n<\/ol>\n<\/section>\n\n<!-- 9. CONTACT -->\n<section id=\"contact\">\n<h2>9. Contact Feichun Cable<span style=\"font-size:.82rem;color:var(--tx3);font-weight:400;margin-left:8px\">\u8054\u7cfb\u98de\u7eaf\u7535\u7f06<\/span><\/h2>\n<div class=\"contact-bar\">\n<p><strong>Anhui Feichun Special Cable Co., Ltd. \u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/strong><\/p>\n<p>For technical enquiries on the TENAX-LUMEN (N)TSCGEH3S series, custom configurations, or quotations, please contact our engineering team:<\/p>\n<p><strong>Email \u90ae\u7bb1:<\/strong><br>\n<a href=\"mailto:tech@feichuncables.com\" rel=\"nofollow\">tech@feichuncables.com<\/a> (Technical \u6280\u672f\u90e8)<br>\n<a href=\"mailto:zihao.yang@feichuncables.com\" rel=\"nofollow\">zihao.yang@feichuncables.com<\/a><br>\n<a href=\"mailto:ziyu.huang@feichuncables.com\" rel=\"nofollow\">ziyu.huang@feichuncables.com<\/a><\/p>\n<p><strong>WhatsApp:<\/strong><\/p>\n<a class=\"wa\" href=\"https:\/\/wa.me\/8613855123218\" rel=\"nofollow noopener\" target=\"_blank\">\ud83d\udcac +86 138 5512 3218<\/a>\n<\/div>\n<\/section>\n\n<!-- FOOTER -->\n<footer>\n<p>&copy; 2025 Anhui Feichun Special Cable Co., Ltd. \u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8. All rights reserved.<\/p>\n<p style=\"margin-top:4px\">TENAX-LUMEN is a trademark of Anhui Feichun Special Cable Co., Ltd.&nbsp;&middot;&nbsp;<a href=\"mailto:tech@feichuncables.com\" rel=\"nofollow\">tech@feichuncables.com<\/a><\/p>\n<\/footer>\n\n<\/div><!-- \/wrapper -->\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"In the German DIN VDE cable designation system \u2014 widely considered the most comprehensive national nomenclature for industrial cables in the world \u2014 every letter and number encodes a specific material, construction feature, or functional characteristic. This convention, governed by standards such as DIN VDE 0292 (Type Designation Codes) and DIN VDE 0250 Part 813 (flexible reeling and trailing cables), allows an engineer to identify a cable&#8217;s conductor type, insulation, screening, protective earth, sheath, and special integrations simply by reading its alphanumeric type code.\n\u5728\u5fb7\u56fd DIN VDE \u7535\u7f06\u547d\u540d\u4f53\u7cfb\u4e2d\u2014\u2014\u88ab\u516c\u8ba4\u4e3a\u5168\u7403\u5de5\u4e1a\u7535\u7f06\u9886\u57df\u6700\u5b8c\u5584\u7684\u56fd\u5bb6\u7ea7\u547d\u540d\u89c4\u8303\u2014\u2014\u6bcf\u4e00\u4e2a\u5b57\u6bcd\u548c\u6570\u5b57\u90fd\u7f16\u7801\u4e86\u7279\u5b9a\u7684\u6750\u6599\u3001\u7ed3\u6784\u7279\u5f81\u6216\u529f\u80fd\u5c5e\u6027\u3002\u8be5\u4f53\u7cfb\u7531 DIN VDE 0292\uff08\u578b\u53f7\u4ee3\u7801\u6807\u51c6\uff09\u548c DIN VDE 0250 \u7b2c 813 \u90e8\u5206\uff08\u67d4\u6027\u5377\u7b52\u4e0e\u62d6\u66f3\u7535\u7f06\uff09\u7b49\u6807\u51c6\u7edf\u4e00\u7ba1\u7406\u3002","protected":false},"author":1,"featured_media":6664,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[66,93,7,56],"tags":[42353,9451,12367,9506,42377,42368,42359,42358,26337,42362,42357,42370,42363,42355,42365,42356,42374,42366,5870,12464,9525,34731,9414,9492,9408,9517,17087,42360,42361,42380,42378,42376,42372,42373,42367,42364,42369,42379,42354,42371,42375,10130],"class_list":["post-6663","post","type-post","status-publish","format-standard","has-post-thumbnail","category-common-problems-encountered-in-cable-applications","category-mining-cable-with-self-sufficient-leds","category-mining-trailing-cable","category-reeling-cable","tag-ntscgeh3s-cable-code-meaning","tag-2kv-led-cable","tag-3-6-6kv-led-cable","tag-cable-bajo-humo-led","tag-cable-designation-code-breakdown","tag-cable-integrated-visible-light-fiber","tag-copper-braided-emc-screened-cable","tag-crane-reeling-cable-with-fiber-optics","tag-din-vde-0250-813-reeling-cable","tag-din-vde-0292-cable-designation-system","tag-epr-insulated-flexible-trailing-cable","tag-feichun-special-cable-manufacturer","tag-gantry-crane-cable-specification","tag-h3-optical-illumination-element-cable","tag-heavy-duty-flexible-cable-din-vde","tag-hybrid-fiber-optic-power-cable","tag-iec-60502-epr-cable","tag-industrial-cable-h-suffix-meaning","tag-led-alternative-mining-cable","tag-led-cable-for-mining-personnel-safety","tag-led-cable-installation-requirements","tag-led-cable-lighting","tag-led-cable-safety","tag-led-cable-vs-traditional","tag-led-integrated-cable","tag-led-integrated-cable-for-underground-mining","tag-led-lamp-flex","tag-medium-voltage-reeling-cable-fiber-optic","tag-mining-cable-integrated-illumination","tag-ntscge-cable-family-comparison","tag-offshore-deck-crane-cable","tag-open-pit-mining-trailing-cable-2","tag-port-crane-sts-rtg-cable","tag-scada-fiber-optic-reeling-cable","tag-side-emitting-fiber-optic-power-cable","tag-silicone-sheath-halogen-free-cable","tag-stage-rigging-hybrid-cable","tag-steel-wire-braid-armor-cable","tag-tenax-lumen-hybrid-cable","tag-tunnel-boring-machine-tbm-cable","tag-42375","tag-10130","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/6663","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=6663"}],"version-history":[{"count":1,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/6663\/revisions"}],"predecessor-version":[{"id":6665,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/6663\/revisions\/6665"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/6664"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=6663"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=6663"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=6663"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}