{"id":6631,"date":"2026-02-09T14:00:55","date_gmt":"2026-02-09T06:00:55","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=6631"},"modified":"2026-02-09T14:00:58","modified_gmt":"2026-02-09T06:00:58","slug":"can-i-use-type-275-epr-csp-to-replace-olex-instalex-xlpe-pvc-for-fixed-hv-transmission","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/can-i-use-type-275-epr-csp-to-replace-olex-instalex-xlpe-pvc-for-fixed-hv-transmission\/","title":{"rendered":"Can I Use Type 275 (EPR\/CSP) to Replace Olex Instalex (XLPE\/PVC) for Fixed HV Transmission?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u6211\u80fd\u5426\u4f7f\u7528 Type 275\uff08EPR\/CSP\uff09\u66ff\u6362 Olex Instalex\uff08XLPE\/PVC\uff09\u7528\u4e8e\u56fa\u5b9a\u9ad8\u538b\u4f20\u8f93\uff1f<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"f4f1e0\" data-has-transparency=\"false\" style=\"--dominant-color: #f4f1e0;\" loading=\"lazy\" decoding=\"async\" width=\"700\" height=\"576\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-777.avif\" alt=\"\" class=\"wp-image-6632 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-777.avif 700w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-777-300x247.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-777-400x329.avif 400w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n<title>Can Type 275 (EPR\/CSP) Replace Olex Instalex (XLPE\/PVC) for Fixed HV Transmission? | Feichun Cable<\/title>\n<meta name=\"description\" content=\"Engineering analysis: Can Type 275 EPR\/CSP mining cable replace Olex Instalex XLPE\/PVC for fixed HV transmission? Standards AS\/NZS 1802 vs AS\/NZS 1429.1, insulation comparison, dielectric data.\">\n<style>\n\/* ===== RESET & VARIABLES ===== *\/\n*,*::before,*::after{box-sizing:border-box;margin:0;padding:0}\n:root{\n--bg:#ffffff;--bg2:#f5f7f9;--bg3:#e8ecf0;--tx:#1b1f2b;--tx2:#505670;\n--ac:#00539b;--ac2:#003a6e;--bd:#cdd5df;--card:#ffffff;\n--th-bg:#00539b;--th-tx:#ffffff;--tr-alt:#f0f4f8;\n--tag-bg:#e3edf7;--tag-tx:#00539b;--sh:0 1px 3px rgba(0,0,0,0.07);\n--warn-bg:#fff8e1;--warn-bd:#f0ad00;--info-bg:#e8f2fc;--info-bd:#1a73e8;\n--ok-bg:#e6f4ea;--ok-bd:#34a853;--err-bg:#fce8e6;--err-bd:#d93025;\n--code-bg:#f3f3f3;--code-tx:#c5221f;--lk:#00539b\n}\n@media(prefers-color-scheme:dark){:root{\n--bg:#0e1118;--bg2:#181c26;--bg3:#242938;--tx:#dce0ea;--tx2:#969bb5;\n--ac:#6eaaed;--ac2:#93c2f5;--bd:#333a4e;--card:#181c26;\n--th-bg:#1a2e4a;--th-tx:#b8d4f0;--tr-alt:#1d2233;\n--tag-bg:#1a2e4a;--tag-tx:#7db8f0;--sh:0 1px 3px rgba(0,0,0,0.3);\n--warn-bg:#332a00;--warn-bd:#a68500;--info-bg:#0c1f38;--info-bd:#4a90d9;\n--ok-bg:#0d2a12;--ok-bd:#2d7a3e;--err-bg:#2d0f0c;--err-bd:#c5221f;\n--code-bg:#1c2030;--code-tx:#f08080;--lk:#7db8f0\n}}\n\/* ===== BASE ===== *\/\nbody{font-family:-apple-system,BlinkMacSystemFont,\"Segoe UI\",Roboto,\"Helvetica Neue\",Arial,sans-serif;background:var(--bg);color:var(--tx);line-height:1.78;font-size:16px;-webkit-font-smoothing:antialiased}\na{color:var(--lk);text-decoration:none}a:hover{text-decoration:underline}\n.w{max-width:960px;margin:0 auto;padding:20px 24px 60px}\n\/* ===== HEADER ===== *\/\n.hd{border-bottom:3px solid var(--ac);padding:16px 0;margin-bottom:28px;display:flex;align-items:center;justify-content:space-between;flex-wrap:wrap;gap:10px}\n.hd .logo{font-size:17px;font-weight:700;color:var(--ac);letter-spacing:-0.3px}\n.hd .logo span{color:var(--tx2);font-weight:400;font-size:12px;display:block}\n.hd nav{display:flex;gap:14px;font-size:12px}.hd nav a{color:var(--tx2);font-weight:500}\n\/* ===== BREADCRUMB ===== *\/\n.bc{font-size:12px;color:var(--tx2);margin-bottom:18px}.bc a{color:var(--tx2)}\n\/* ===== ARTICLE ===== *\/\narticle{width:100%}\n.meta{margin-bottom:22px}\n.meta .cat{display:inline-block;background:var(--ac);color:#fff;font-size:10px;font-weight:700;padding:3px 10px;border-radius:3px;text-transform:uppercase;letter-spacing:.6px;margin-bottom:8px}\nh1{font-size:clamp(21px,3.8vw,28px);font-weight:800;line-height:1.3;color:var(--tx);margin-bottom:4px}\nh1 .cn{display:block;font-size:clamp(14px,2.2vw,17px);font-weight:500;color:var(--tx2);margin-top:5px}\n.pub{font-size:12px;color:var(--tx2);margin-top:6px}\nh2{font-size:19px;font-weight:700;color:var(--tx);margin:34px 0 12px;padding-bottom:7px;border-bottom:2px solid var(--bd)}\nh2 .cn{font-weight:400;color:var(--tx2);font-size:14px}\nh3{font-size:16px;font-weight:600;color:var(--tx);margin:22px 0 8px}\nh3 .cn{font-weight:400;color:var(--tx2);font-size:13px}\np{margin-bottom:14px;color:var(--tx)}\n.cn-p{font-size:14px;color:var(--tx2);margin-bottom:16px;line-height:1.7}\n\/* ===== TABLE ===== *\/\n.tw{width:100%;overflow-x:auto;margin:18px 0;border-radius:5px;border:1px solid var(--bd);box-shadow:var(--sh)}\ntable{width:100%;border-collapse:collapse;font-size:13.5px;min-width:620px}\nthead{background:var(--th-bg)}\nthead th{color:var(--th-tx);font-weight:600;padding:10px 12px;text-align:left;white-space:nowrap;font-size:12.5px;letter-spacing:.3px}\ntbody td{padding:9px 12px;border-bottom:1px solid var(--bd);color:var(--tx);vertical-align:top}\ntbody tr:nth-child(even){background:var(--tr-alt)}\ntbody tr:hover{background:var(--bg3)}\ncaption{caption-side:top;text-align:left;font-size:12px;font-weight:600;color:var(--tx2);padding:7px 12px;background:var(--bg2);border-bottom:1px solid var(--bd)}\ntd.em{font-weight:600;color:var(--ac)}\n\/* ===== BOXES ===== *\/\n.bx{padding:13px 16px;border-radius:5px;margin:18px 0;border-left:4px solid;font-size:13.5px;line-height:1.65}\n.bx.warn{background:var(--warn-bg);border-color:var(--warn-bd)}\n.bx.info{background:var(--info-bg);border-color:var(--info-bd)}\n.bx.ok{background:var(--ok-bg);border-color:var(--ok-bd)}\n.bx.err{background:var(--err-bg);border-color:var(--err-bd)}\n.bx strong{display:block;margin-bottom:3px;font-size:12px;text-transform:uppercase;letter-spacing:.5px}\n\/* ===== VERDICT ===== *\/\n.verdict{background:var(--bg2);border:2px solid var(--bd);border-radius:6px;padding:18px 20px;margin:22px 0}\n.verdict h3{margin-top:0;font-size:17px;color:var(--ac)}\n\/* ===== TAGS ===== *\/\n.tags{display:flex;flex-wrap:wrap;gap:5px;margin:10px 0}\n.tags span{background:var(--tag-bg);color:var(--tag-tx);font-size:10.5px;padding:3px 9px;border-radius:3px;font-weight:500}\n\/* ===== REFS ===== *\/\n.refs{margin-top:34px;padding-top:18px;border-top:2px solid var(--bd)}\n.refs h2{border:none;padding:0;margin-bottom:10px}\n.rl{counter-reset:r;font-size:12.5px;color:var(--tx2);list-style:none;padding:0}\n.rl li{counter-increment:r;margin-bottom:7px;padding-left:4px;line-height:1.55}\n.rl li::before{content:\"[\"counter(r)\"] \";font-weight:700;color:var(--ac)}\n.rl a{word-break:break-all}\n\/* ===== CONTACT ===== *\/\n.ct{background:var(--bg2);border:1px solid var(--bd);border-radius:5px;padding:16px 18px;margin-top:28px;font-size:13px}\n.ct .t{font-weight:700;margin-bottom:6px;color:var(--tx)}\n.cr{display:flex;flex-wrap:wrap;gap:8px 22px;font-size:12.5px;color:var(--tx2)}\n.cr a{color:var(--lk);font-weight:500}\n\/* ===== FOOTER ===== *\/\nfooter{margin-top:36px;padding-top:16px;border-top:1px solid var(--bd);font-size:11.5px;color:var(--tx2);text-align:center}\n\/* ===== CODE ===== *\/\ncode{background:var(--code-bg);color:var(--code-tx);padding:1px 5px;border-radius:3px;font-size:12.5px;font-family:\"SF Mono\",Consolas,monospace}\n\/* ===== RESPONSIVE ===== *\/\n@media(max-width:640px){.w{padding:12px 14px 36px}table{font-size:12px}thead th,tbody td{padding:7px 8px}}\n<\/style>\n<\/head>\n<body>\n<div class=\"w\">\n\n<header class=\"hd\">\n<div class=\"logo\">FEICHUN CABLE<span>\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8 \u2014 Anhui Feichun Special Cable Co., Ltd.<\/span><\/div>\n<nav>\n<a href=\"mailto:tech@feichuncables.com\" rel=\"nofollow noopener\" target=\"_blank\">Tech Support<\/a>\n<a href=\"https:\/\/wa.me\/8613855123218\" rel=\"nofollow noopener\" target=\"_blank\">WhatsApp<\/a>\n<\/nav>\n<\/header>\n\n<div class=\"bc\">Home &gt; Technical Blog &gt; Type 275 vs Olex Instalex<\/div>\n\n<article>\n<div class=\"meta\">\n<span class=\"cat\">HV Cable Engineering \u9ad8\u538b\u7535\u7f06\u5de5\u7a0b<\/span>\n<h1>Can I Use Type 275 (EPR\/CSP) to Replace Olex Instalex (XLPE\/PVC) for Fixed HV Transmission?\n<span class=\"cn\">\u6211\u80fd\u5426\u4f7f\u7528 Type 275\uff08EPR\/CSP\uff09\u66ff\u6362 Olex Instalex\uff08XLPE\/PVC\uff09\u7528\u4e8e\u56fa\u5b9a\u9ad8\u538b\u4f20\u8f93\uff1f<\/span><\/h1>\n<div class=\"pub\">Published: 2026-02-09 &nbsp;|&nbsp; Author: Feichun Cable Technical Team &nbsp;|&nbsp; Reading: ~14 min<\/div>\n<\/div>\n\n<div class=\"tags\">\n<span>Type 275<\/span><span>Olex Instalex<\/span><span>EPR Insulation<\/span><span>XLPE\/PVC<\/span><span>AS\/NZS 1429.1<\/span><span>AS\/NZS 1802<\/span><span>Fixed HV Cable<\/span><span>Mining Cable<\/span><span>CSP Sheath<\/span><span>Water Treeing<\/span>\n<\/div>\n\n<!-- ===== 1. INTRODUCTION ===== -->\n<h2>1. Introduction <span class=\"cn\">\u5f15\u8a00<\/span><\/h2>\n<p>This is a question that arises frequently on Australian and New Zealand mining and industrial project sites: a contractor has Olex Instalex XLPE\/PVC cable specified for a fixed high-voltage (HV) power transmission run, but Type 275 EPR\/CSP cable is readily available in stock or already on-site for mining equipment. Can one be substituted for the other?<\/p>\n<p class=\"cn-p\">\uff08\u8fd9\u4e2a\u95ee\u9898\u7ecf\u5e38\u51fa\u73b0\u5728\u6fb3\u5927\u5229\u4e9a\u548c\u65b0\u897f\u5170\u7684\u77ff\u4e1a\u53ca\u5de5\u4e1a\u9879\u76ee\u73b0\u573a\uff1a\u8bbe\u8ba1\u6307\u5b9a\u4e86 Olex Instalex XLPE\/PVC \u7535\u7f06\u7528\u4e8e\u56fa\u5b9a\u9ad8\u538b\u4f20\u8f93\uff0c\u4f46\u73b0\u573a\u5df2\u6709 Type 275 EPR\/CSP \u77ff\u7528\u7535\u7f06\u5e93\u5b58\u3002\u4e24\u8005\u80fd\u5426\u4e92\u6362\uff1f\uff09<\/p>\n\n<p>The short answer is: <strong>No \u2014 not as a direct, like-for-like replacement.<\/strong> While both cable families can carry high-voltage power, they are engineered to fundamentally different standards, for different installation categories, and their insulation and sheath materials serve distinct operational roles. However, the longer engineering answer involves nuance \u2014 there are scenarios where an EPR-insulated cable <em>designed to AS\/NZS 1429.1<\/em> could serve as a legitimate alternative to XLPE. Understanding the distinction requires a close look at the standards, construction details, and electrical parameters of each cable type.<\/p>\n<p class=\"cn-p\">\uff08\u7b80\u77ed\u56de\u7b54\u662f\uff1a<strong>\u4e0d\u80fd\u76f4\u63a5\u4e00\u5bf9\u4e00\u66ff\u6362\u3002<\/strong>\u4e24\u79cd\u7535\u7f06\u867d\u90fd\u53ef\u4f20\u8f93\u9ad8\u538b\u7535\u529b\uff0c\u4f46\u5206\u522b\u4f9d\u636e\u4e0d\u540c\u6807\u51c6\u5236\u9020\uff0c\u9002\u7528\u4e8e\u4e0d\u540c\u5b89\u88c5\u7c7b\u522b\uff0c\u7edd\u7f18\u548c\u62a4\u5957\u6750\u6599\u627f\u62c5\u4e0d\u540c\u5de5\u7a0b\u89d2\u8272\u3002\u4f46\u5de5\u7a0b\u5c42\u9762\u6709\u7ec6\u5fae\u5dee\u522b\u2014\u2014\u6309 AS\/NZS 1429.1 \u8bbe\u8ba1\u7684 EPR \u7edd\u7f18\u7535\u7f06\u5728\u67d0\u4e9b\u573a\u666f\u4e0b\u53ef\u4f5c\u4e3a\u5408\u89c4\u66ff\u4ee3\u65b9\u6848\u3002\u7406\u89e3\u4e24\u8005\u5dee\u5f02\u9700\u6df1\u5165\u5bf9\u6bd4\u6807\u51c6\u3001\u7ed3\u6784\u548c\u7535\u6c14\u53c2\u6570\u3002\uff09<\/p>\n\n<!-- ===== 2. TWO CABLES ===== -->\n<h2>2. Identifying the Two Cables <span class=\"cn\">\u4e24\u79cd\u7535\u7f06\u7684\u8eab\u4efd\u9274\u5b9a<\/span><\/h2>\n\n<h3>2.1 Olex Instalex \u2014 XLPE\/PVC Fixed HV Cable <span class=\"cn\">Olex Instalex \u2014 XLPE\/PVC \u56fa\u5b9a\u9ad8\u538b\u7535\u7f06<\/span><\/h3>\n<p>Olex (now Nexans Australia) manufactures a range of medium-voltage and high-voltage XLPE-insulated cables for fixed installations, manufactured in accordance with AS\/NZS 1429.1. This standard, based on IEC 60502.2, specifies requirements for cross-linked polyethylene (XLPE) and ethylene propylene rubber (EPR) insulated, individually screened single-core and three-core cables for fixed installations at working voltages from 1.9\/3.3 (3.6) kV up to and including 19\/33 (36) kV. A typical Olex HV cable construction includes a compacted stranded copper or aluminium conductor (to AS\/NZS 1125 and IEC 60228), a semiconductive conductor screen, XLPE insulation, a strippolex (strippable) semiconductive insulation screen, a helical copper tape or wire metallic screen, and a PVC outer sheath.<\/p>\n<p class=\"cn-p\">\uff08Olex\uff08\u73b0\u4e3a Nexans \u6fb3\u5927\u5229\u4e9a\uff09\u6309\u7167 AS\/NZS 1429.1 \u5236\u9020\u4e00\u7cfb\u5217\u4e2d\/\u9ad8\u538b XLPE \u7edd\u7f18\u56fa\u5b9a\u5b89\u88c5\u7535\u7f06\u3002\u8be5\u6807\u51c6\u57fa\u4e8e IEC 60502.2\uff0c\u9002\u7528\u4e8e 1.9\/3.3 kV \u81f3 19\/33 kV \u56fa\u5b9a\u5b89\u88c5\u7535\u7f06\u3002\u5178\u578b\u7ed3\u6784\u5305\u62ec\uff1a\u538b\u7d27\u7ede\u5408\u94dc\/\u94dd\u5bfc\u4f53\u3001\u534a\u5bfc\u7535\u5bfc\u4f53\u5c4f\u853d\u3001XLPE \u7edd\u7f18\u3001\u53ef\u5265\u79bb\u534a\u5bfc\u7535\u7edd\u7f18\u5c4f\u853d\u3001\u94dc\u5e26\/\u94dc\u4e1d\u91d1\u5c5e\u5c4f\u853d\u53ca PVC \u5916\u62a4\u5957\u3002\uff09<\/p>\n\n<h3>2.2 Type 275 \u2014 EPR\/CSP Flexible Mining Cable <span class=\"cn\">Type 275 \u2014 EPR\/CSP \u67d4\u6027\u77ff\u7528\u7535\u7f06<\/span><\/h3>\n<p>Type 275 is a flexible low-voltage cable defined under AS\/NZS 1802 (Electric Cables \u2014 Rubber Insulated \u2014 for Working Voltages Up to and Including 0.6\/1 kV). It is designed primarily for underground coal mining applications, notably as a flexible feeder cable for shuttle cars and pump power supply. It features a 3+3+1 configuration: three power cores with EPR (R-EP-90) insulation, three semiconductive elastomer-covered earth cores in the interstices, and a single central extensible pilot core providing reinforcement. The outer sheath is Heavy-Duty Chlorosulphonated Polyethylene (HD-CSP, also known as CSPE or historically &#8220;Hypalon&#8221;), with a polyamide yarn reinforcement braid beneath it.<\/p>\n<p class=\"cn-p\">\uff08Type 275 \u662f\u4e00\u79cd\u6309 AS\/NZS 1802 \u5236\u9020\u7684\u67d4\u6027\u4f4e\u538b\u77ff\u7528\u7535\u7f06\uff0c\u4e3b\u8981\u7528\u4e8e\u7164\u77ff\u4e95\u4e0b\u7a7f\u68ad\u8f66\u548c\u6c34\u6cf5\u4f9b\u7535\u3002\u7ed3\u6784\u4e3a 3+3+1 \u914d\u7f6e\uff1a\u4e09\u6839 EPR\uff08R-EP-90\uff09\u7edd\u7f18\u52a8\u529b\u82af\u3001\u4e09\u6839\u534a\u5bfc\u7535\u5f39\u6027\u4f53\u63a5\u5730\u82af\u53ca\u4e00\u6839\u4e2d\u5fc3\u5f15\u5bfc\u82af\u3002\u5916\u62a4\u5957\u4e3a\u91cd\u578b\u6c2f\u78fa\u5316\u805a\u4e59\u70ef\uff08HD-CSP\uff09\uff0c\u5176\u4e0b\u6709\u805a\u9170\u80fa\u7eb1\u589e\u5f3a\u7f16\u7ec7\u5c42\u3002\uff09<\/p>\n\n<div class=\"bx err\">\n<strong>Critical Distinction \u5173\u952e\u533a\u522b<\/strong>\nType 275 is rated at <strong>1.1 kV<\/strong> and manufactured to <strong>AS\/NZS 1802<\/strong> (flexible mining cables). Olex Instalex HV cables are rated from <strong>3.3 kV to 33 kV<\/strong> and manufactured to <strong>AS\/NZS 1429.1<\/strong> (fixed-installation polymeric-insulated HV cables). These are <em>entirely different cable standards<\/em> governing different voltage classes, installation categories, and testing regimes.<br>\n\uff08Type 275 \u989d\u5b9a\u7535\u538b <strong>1.1 kV<\/strong>\uff0c\u6309 <strong>AS\/NZS 1802<\/strong> \u5236\u9020\u3002Olex Instalex HV \u7535\u7f06\u989d\u5b9a <strong>3.3 kV \u81f3 33 kV<\/strong>\uff0c\u6309 <strong>AS\/NZS 1429.1<\/strong> \u5236\u9020\u3002\u4e24\u8005\u5c5e\u4e8e\u5b8c\u5168\u4e0d\u540c\u7684\u7535\u7f06\u6807\u51c6\uff0c\u8986\u76d6\u4e0d\u540c\u7535\u538b\u7b49\u7ea7\u3001\u5b89\u88c5\u7c7b\u522b\u548c\u6d4b\u8bd5\u4f53\u7cfb\u3002\uff09\n<\/div>\n\n<!-- ===== 3. SIDE BY SIDE ===== -->\n<h2>3. Head-to-Head Construction and Parameter Comparison <span class=\"cn\">\u7ed3\u6784\u4e0e\u53c2\u6570\u6b63\u9762\u5bf9\u6bd4<\/span><\/h2>\n\n<div class=\"tw\">\n<table>\n<caption>Table 1 \u2014 Fundamental Specification Comparison \u88681 \u2014 \u57fa\u672c\u89c4\u683c\u5bf9\u6bd4<\/caption>\n<thead><tr><th>Parameter \u53c2\u6570<\/th><th>Type 275 (EPR\/CSP)<\/th><th>Olex Instalex HV (XLPE\/PVC)<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Governing Standard \u6267\u884c\u6807\u51c6<\/td><td class=\"em\">AS\/NZS 1802:2003<\/td><td class=\"em\">AS\/NZS 1429.1:2006 (based on IEC 60502.2)<\/td><\/tr>\n<tr><td>Design Application \u8bbe\u8ba1\u7528\u9014<\/td><td>Flexible trailing\/feeder cable for underground mining equipment (shuttle cars, pumps)<\/td><td>Fixed installation for electricity supply (HV transmission &amp; distribution)<\/td><\/tr>\n<tr><td>Voltage Rating \u989d\u5b9a\u7535\u538b<\/td><td class=\"em\">1.1 kV (max.)<\/td><td class=\"em\">1.9\/3.3 kV to 19\/33 kV<\/td><\/tr>\n<tr><td>Conductor \u5bfc\u4f53<\/td><td>Flexible tinned copper (high strand count, Class 5\/6)<\/td><td>Compacted stranded copper or aluminium (Class 2) to AS\/NZS 1125<\/td><\/tr>\n<tr><td>Insulation \u7edd\u7f18<\/td><td class=\"em\">EPR (R-EP-90), 90 \u00b0C rated<\/td><td class=\"em\">XLPE (X-90), 90 \u00b0C rated (also EPR option per AS\/NZS 1429.1)<\/td><\/tr>\n<tr><td>Insulation Screen \u7edd\u7f18\u5c4f\u853d<\/td><td>Semiconductive thermosetting compound<\/td><td>Semiconductive strippable compound (&#8220;Strippolex&#8221;)<\/td><\/tr>\n<tr><td>Metallic Screen \u91d1\u5c5e\u5c4f\u853d<\/td><td>None (non-individually screened power cores)<\/td><td>Helical copper tape or copper wire screen (individual core screening)<\/td><\/tr>\n<tr><td>Earth Configuration \u63a5\u5730\u914d\u7f6e<\/td><td>3 \u00d7 semiconductive elastomer-covered earths in interstices + pilot core<\/td><td>Separate earth conductor or cable screen earthing per utility requirements<\/td><\/tr>\n<tr><td>Outer Sheath \u5916\u62a4\u5957<\/td><td class=\"em\">HD-85-CSP (Chlorosulphonated Polyethylene) with polyamide yarn reinforcement<\/td><td class=\"em\">PVC (5V-90) or HDPE outer sheath<\/td><\/tr>\n<tr><td>Armour \u94e0\u88c5<\/td><td>None (yarn braid reinforcement)<\/td><td>Optional: steel wire armour (SWA) or aluminium wire armour<\/td><\/tr>\n<tr><td>Installation Mode \u5b89\u88c5\u65b9\u5f0f<\/td><td class=\"em\">Mobile \/ flexible \/ trailing (frequent bending, reeling)<\/td><td class=\"em\">Fixed (buried, ducted, ladder, tray \u2014 permanent installation)<\/td><\/tr>\n<tr><td>Min. Operating Temp. \u6700\u4f4e\u5de5\u4f5c\u6e29\u5ea6<\/td><td>\u221225 \u00b0C<\/td><td>\u221220 \u00b0C (installation); continuous to 90 \u00b0C<\/td><\/tr>\n<tr><td>Flame Retardance \u963b\u71c3<\/td><td>Yes (to AS\/NZS 1802 requirements)<\/td><td>Yes (to IEC 60332 \/ AS requirements)<\/td><\/tr>\n<tr><td>Water Blocking \u963b\u6c34<\/td><td>Not specified<\/td><td>Optional (water-blocking compounds per AS\/NZS 1429.1 Clause 2.14)<\/td><\/tr>\n<tr><td>Typical Cross-Sections \u5178\u578b\u622a\u9762<\/td><td>10 mm\u00b2 to 120 mm\u00b2<\/td><td>25 mm\u00b2 to 630 mm\u00b2 (Cu); up to 1000 mm\u00b2 (Al)<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<!-- ===== 4. WHY NOT ===== -->\n<h2>4. Why Type 275 Cannot Directly Replace Olex Instalex for Fixed HV <span class=\"cn\">\u4e3a\u4f55 Type 275 \u4e0d\u80fd\u76f4\u63a5\u66ff\u6362 Olex Instalex \u7528\u4e8e\u56fa\u5b9a\u9ad8\u538b\u4f20\u8f93<\/span><\/h2>\n\n<h3>4.1 Voltage Class Incompatibility <span class=\"cn\">\u7535\u538b\u7b49\u7ea7\u4e0d\u517c\u5bb9<\/span><\/h3>\n<p>The most fundamental barrier is voltage rating. Type 275 is rated at 1.1 kV maximum under AS\/NZS 1802. Olex Instalex HV cables operate at voltage levels starting from 1.9\/3.3 kV and going up to 19\/33 kV. No amount of installation engineering can overcome a cable that has been insulated, tested, and certified for 1.1 kV being placed into a 6.6 kV, 11 kV, or 22 kV circuit. The insulation wall thickness, the partial discharge (PD) test requirements, and the impulse withstand voltage (BIL) ratings specified in AS\/NZS 1429.1 are orders of magnitude beyond what AS\/NZS 1802 demands for a 1.1 kV cable.<\/p>\n<p class=\"cn-p\">\uff08\u6700\u6839\u672c\u969c\u788d\u662f\u7535\u538b\u7b49\u7ea7\u3002Type 275 \u6700\u9ad8\u989d\u5b9a 1.1 kV\uff0c\u800c Olex Instalex HV \u7535\u7f06\u4ece 1.9\/3.3 kV \u8d77\u81f3 19\/33 kV\u3002\u7edd\u7f18\u58c1\u539a\u3001\u5c40\u90e8\u653e\u7535\u6d4b\u8bd5\u8981\u6c42\u53ca\u51b2\u51fb\u8010\u53d7\u7535\u538b\u7b49\u7ea7\u5728 AS\/NZS 1429.1 \u4e2d\u8fdc\u8d85 AS\/NZS 1802 \u5bf9 1.1 kV \u7535\u7f06\u7684\u8981\u6c42\u3002\uff09<\/p>\n\n<h3>4.2 Individual Core Screening Requirement <span class=\"cn\">\u5355\u82af\u72ec\u7acb\u5c4f\u853d\u8981\u6c42<\/span><\/h3>\n<p>AS\/NZS 1429.1 mandates that each cable core be individually screened with a metallic layer (copper tape or wire screen) over a semiconductive insulation screen. This metallic screen serves several critical functions in HV systems: it confines the electric field within a defined radial geometry, it provides a path for capacitive charging current and fault current, and it enables safe cable termination and jointing. Type 275 has <em>non-individually screened<\/em> power cores. Its semiconductive screens are present for mechanical and surface-resistivity purposes typical of mining cables, but it lacks the precision metallic screening required for HV electric field control. Without individual core screening, installing Type 275 in an HV system would create uncontrolled electric field gradients, leading to corona discharge, partial discharge, and rapid insulation degradation.<\/p>\n<p class=\"cn-p\">\uff08AS\/NZS 1429.1 \u8981\u6c42\u6bcf\u6839\u82af\u7ebf\u5355\u72ec\u91d1\u5c5e\u5c4f\u853d\uff08\u94dc\u5e26\u6216\u94dc\u4e1d\uff09\uff0c\u7528\u4e8e\u7ea6\u675f\u7535\u573a\u3001\u63d0\u4f9b\u5bb9\u6027\u5145\u7535\u53ca\u6545\u969c\u7535\u6d41\u901a\u8def\uff0c\u5e76\u786e\u4fdd\u5b89\u5168\u7ec8\u7aef\u5904\u7406\u3002Type 275 \u7684\u52a8\u529b\u82af\u7ebf\u6ca1\u6709\u5355\u72ec\u91d1\u5c5e\u5c4f\u853d\u3002\u5728\u9ad8\u538b\u7cfb\u7edf\u4e2d\u4f7f\u7528\u4f1a\u5bfc\u81f4\u7535\u573a\u5206\u5e03\u5931\u63a7\u3001\u7535\u6655\u653e\u7535\u3001\u5c40\u90e8\u653e\u7535\u548c\u7edd\u7f18\u5feb\u901f\u9000\u5316\u3002\uff09<\/p>\n\n<h3>4.3 Conductor Class Mismatch <span class=\"cn\">\u5bfc\u4f53\u7b49\u7ea7\u4e0d\u5339\u914d<\/span><\/h3>\n<p>Type 275 uses highly flexible tinned copper conductors (Class 5 or Class 6 stranding) designed for frequent bending, reeling, and trailing across mine floors. Olex Instalex HV cables use compacted stranded conductors (typically Class 2 per AS\/NZS 1125 and IEC 60228) that are optimized for fixed installations: lower DC resistance per unit length, smaller outer diameter (due to compaction), and compatibility with standardized HV cable terminations and joints. Using a Class 5\/6 flexible conductor in a fixed HV termination can lead to difficulties in achieving reliable electrical contact and maintaining the dimensional stability required by prefabricated HV accessories (heat-shrink terminations, cold-shrink joints, etc.).<\/p>\n<p class=\"cn-p\">\uff08Type 275 \u4f7f\u7528\u9ad8\u67d4\u6027\u9540\u9521\u94dc\u5bfc\u4f53\uff08Class 5\/6\uff09\uff0c\u9002\u5408\u9891\u7e41\u5f2f\u66f2\u548c\u5377\u7ed5\u3002Olex Instalex HV \u7535\u7f06\u4f7f\u7528\u538b\u7d27\u7ede\u5408\u5bfc\u4f53\uff08Class 2\uff09\uff0c\u5177\u6709\u66f4\u4f4e\u5355\u4f4d\u957f\u5ea6\u7535\u963b\u3001\u66f4\u5c0f\u5916\u5f84\uff0c\u4e14\u4e0e\u6807\u51c6\u5316\u9ad8\u538b\u7ec8\u7aef\u548c\u63a5\u5934\u517c\u5bb9\u3002\u5c06 Class 5\/6 \u67d4\u6027\u5bfc\u4f53\u7528\u4e8e\u56fa\u5b9a\u9ad8\u538b\u7ec8\u7aef\u53ef\u80fd\u5bfc\u81f4\u63a5\u89e6\u53ef\u9760\u6027\u548c\u5c3a\u5bf8\u7a33\u5b9a\u6027\u95ee\u9898\u3002\uff09<\/p>\n\n<h3>4.4 Sheath Material Considerations <span class=\"cn\">\u62a4\u5957\u6750\u6599\u8003\u91cf<\/span><\/h3>\n<p>The CSP (Chlorosulphonated Polyethylene) heavy-duty sheath on Type 275 is an outstanding material for mining and industrial environments. As noted by Tratos Group, CSP offers superior resistance to heat, oxidizing chemicals, ozone, and moisture compared to standard neoprene, with excellent impact, abrasion, and crush resistance and a temperature range from \u221240 \u00b0C up to +120 \u00b0C. However, for fixed buried or ducted HV cable installations, PVC or HDPE sheaths (as used on Olex Instalex) are the standard specified materials in AS\/NZS 1429.1 \u2014 and these are the materials for which the thermal resistivity values in cable rating calculations (per AS\/NZS 3008 and IEC 60287) are calibrated. A CSP sheath has different thermal characteristics, and the cable&#8217;s current-carrying capacity (ampacity) calculations under AS\/NZS 1429.1 methodology would not be directly applicable.<\/p>\n<p class=\"cn-p\">\uff08Type 275 \u7684 CSP \u91cd\u578b\u62a4\u5957\u5728\u77ff\u7528\u73af\u5883\u4e2d\u6027\u80fd\u5353\u8d8a\u3002\u4f46 AS\/NZS 1429.1 \u89c4\u5b9a\u7684\u56fa\u5b9a\u57cb\u8bbe\/\u7ba1\u9053\u9ad8\u538b\u7535\u7f06\u6807\u51c6\u62a4\u5957\u6750\u6599\u4e3a PVC \u6216 HDPE\uff0c\u5176\u70ed\u963b\u7387\u5df2\u7eb3\u5165 IEC 60287 \u8f7d\u6d41\u91cf\u8ba1\u7b97\u6821\u51c6\u3002CSP \u62a4\u5957\u70ed\u7279\u6027\u4e0d\u540c\uff0c\u8f7d\u6d41\u91cf\u8ba1\u7b97\u65e0\u6cd5\u76f4\u63a5\u5957\u7528\u3002\uff09<\/p>\n\n<div class=\"tw\">\n<table>\n<caption>Table 2 \u2014 Sheath Material Property Comparison \u88682 \u2014 \u62a4\u5957\u6750\u6599\u6027\u80fd\u5bf9\u6bd4<\/caption>\n<thead><tr><th>Property \u6027\u80fd<\/th><th>PVC (5V-90) \u805a\u6c2f\u4e59\u70ef<\/th><th>CSP \/ CSPE \u6c2f\u78fa\u5316\u805a\u4e59\u70ef<\/th><th>HDPE \u9ad8\u5bc6\u5ea6\u805a\u4e59\u70ef<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Temperature Range \u6e29\u5ea6\u8303\u56f4<\/td><td>\u221220 to +90 \u00b0C<\/td><td>\u221240 to +120 \u00b0C<\/td><td>\u221240 to +70 \u00b0C<\/td><\/tr>\n<tr><td>Oil Resistance \u8010\u6cb9\u6027<\/td><td>Moderate \u4e2d\u7b49<\/td><td>Excellent \u4f18\u5f02<\/td><td>Good \u826f\u597d<\/td><\/tr>\n<tr><td>UV \/ Ozone Resistance \u8010\u7d2b\u5916\/\u81ed\u6c27<\/td><td>Good (with stabilizers) \u826f\u597d<\/td><td>Excellent \u4f18\u5f02<\/td><td>Good \u826f\u597d<\/td><\/tr>\n<tr><td>Flame Retardance \u963b\u71c3<\/td><td>Good (inherent) \u826f\u597d\uff08\u56fa\u6709\uff09<\/td><td>Good \u826f\u597d<\/td><td>Poor (needs additives) \u5dee<\/td><\/tr>\n<tr><td>Abrasion \/ Impact Resistance \u8010\u78e8\/\u6297\u51b2\u51fb<\/td><td>Moderate \u4e2d\u7b49<\/td><td>Excellent \u4f18\u5f02<\/td><td>Good \u826f\u597d<\/td><\/tr>\n<tr><td>Moisture Resistance \u9632\u6f6e<\/td><td>Good \u826f\u597d<\/td><td>Excellent (very low absorption) \u4f18\u5f02<\/td><td>Excellent \u4f18\u5f02<\/td><\/tr>\n<tr><td>Flexibility \u67d4\u6027<\/td><td>Moderate (stiffens in cold) \u4e2d\u7b49<\/td><td>Excellent \u4f18\u5f02<\/td><td>Moderate \u4e2d\u7b49<\/td><\/tr>\n<tr><td>Halogen Content \u542b\u5364<\/td><td>Yes \u662f<\/td><td>Yes \u662f<\/td><td>No \u5426<\/td><\/tr>\n<tr><td>Cost \u6210\u672c<\/td><td>Low \u4f4e<\/td><td>High \u9ad8<\/td><td>Moderate \u4e2d\u7b49<\/td><\/tr>\n<tr><td>AS\/NZS 1429.1 Compliance \u5408\u89c4<\/td><td class=\"em\">Yes \u662f<\/td><td>Not standard \u975e\u6807\u51c6<\/td><td class=\"em\">Yes \u662f<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<!-- ===== 5. INSULATION ===== -->\n<h2>5. EPR vs. XLPE Insulation: The Technical Merits <span class=\"cn\">EPR \u4e0e XLPE \u7edd\u7f18\uff1a\u6280\u672f\u4f18\u52a3\u5206\u6790<\/span><\/h2>\n<p>Although Type 275 itself is not a suitable replacement, the underlying question of whether EPR insulation could serve in place of XLPE for fixed HV transmission has genuine engineering merit. It is important to understand that AS\/NZS 1429.1 actually permits <em>both<\/em> XLPE and EPR as insulation materials for fixed HV installations. The standard&#8217;s full title is: &#8220;Electric Cables \u2014 Polymeric Insulated \u2014 Part 1: For Working Voltages 1.9\/3.3 (3.6) kV Up to and Including 19\/33 (36) kV&#8221; and it covers both cross-linked polyethylene (XLPE) and ethylene propylene rubber (EPR) insulated cables. Therefore, EPR insulation in principle is fully acceptable for fixed HV use \u2014 <em>provided the cable is designed and tested to AS\/NZS 1429.1<\/em>, not to AS\/NZS 1802.<\/p>\n<p class=\"cn-p\">\uff08\u867d\u7136 Type 275 \u672c\u8eab\u4e0d\u9002\u5408\u66ff\u6362\uff0c\u4f46 EPR \u7edd\u7f18\u7528\u4e8e\u56fa\u5b9a\u9ad8\u538b\u4f20\u8f93\u7684\u95ee\u9898\u786e\u6709\u5de5\u7a0b\u4ef7\u503c\u3002AS\/NZS 1429.1 \u5b9e\u9645\u4e0a\u540c\u65f6\u5141\u8bb8 XLPE \u548c EPR \u4f5c\u4e3a\u7edd\u7f18\u6750\u6599\u2014\u2014\u524d\u63d0\u662f\u7535\u7f06\u6309 AS\/NZS 1429.1 \u8bbe\u8ba1\u548c\u6d4b\u8bd5\uff0c\u800c\u975e AS\/NZS 1802\u3002\uff09<\/p>\n\n<div class=\"tw\">\n<table>\n<caption>Table 3 \u2014 EPR vs. XLPE Insulation Technical Comparison for HV Cables \u88683 \u2014 EPR \u4e0e XLPE \u7edd\u7f18\u5728\u9ad8\u538b\u7535\u7f06\u4e2d\u7684\u6280\u672f\u5bf9\u6bd4<\/caption>\n<thead><tr><th>Property \u6027\u80fd<\/th><th>XLPE (Cross-Linked PE) \u4ea4\u8054\u805a\u4e59\u70ef<\/th><th>EPR (Ethylene Propylene Rubber) \u4e59\u4e19\u6a61\u80f6<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Molecular Structure \u5206\u5b50\u7ed3\u6784<\/td><td>Semi-crystalline (cross-linked)<\/td><td>Amorphous (non-crystalline)<\/td><\/tr>\n<tr><td>Dielectric Constant (\u03b5<sub>r<\/sub>) \u4ecb\u7535\u5e38\u6570<\/td><td class=\"em\">2.3 \u2013 2.5 (lower = better)<\/td><td>2.8 \u2013 3.5<\/td><\/tr>\n<tr><td>Dissipation Factor (tan \u03b4) \u4ecb\u635f\u56e0\u5b50<\/td><td class=\"em\">0.0003 \u2013 0.001<\/td><td>0.003 \u2013 0.008 (higher losses)<\/td><\/tr>\n<tr><td>Dielectric Strength \u51fb\u7a7f\u573a\u5f3a<\/td><td>Higher (thinner insulation possible)<\/td><td>Good, but slightly lower<\/td><\/tr>\n<tr><td>Continuous Temp. Rating \u8fde\u7eed\u6e29\u5ea6\u989d\u5b9a<\/td><td>90 \u00b0C (MV-90)<\/td><td>90 \u00b0C (MV-90) or 105 \u00b0C (MV-105)<\/td><\/tr>\n<tr><td>Emergency Overload \u7d27\u6025\u8fc7\u8f7d<\/td><td>130 \u00b0C<\/td><td>130\u2013140 \u00b0C<\/td><\/tr>\n<tr><td>Short-Circuit Temp. \u77ed\u8def\u6e29\u5ea6<\/td><td>250 \u00b0C<\/td><td>250 \u00b0C<\/td><\/tr>\n<tr><td>Water Treeing Resistance \u6297\u6c34\u6811<\/td><td>Susceptible (TR-XLPE improves this) \u6613\u53d7\u5f71\u54cd<\/td><td class=\"em\">Excellent (amorphous structure resists treeing) \u4f18\u5f02<\/td><\/tr>\n<tr><td>Flexibility \u67d4\u6027<\/td><td>Stiff (especially large sizes and cold temperatures)<\/td><td class=\"em\">Excellent (easier conduit installation)<\/td><\/tr>\n<tr><td>Thermal Expansion \u70ed\u81a8\u80c0<\/td><td>Significant \u663e\u8457<\/td><td class=\"em\">Reduced \u8f83\u5c0f<\/td><\/tr>\n<tr><td>Partial Discharge Resistance \u8010\u5c40\u653e<\/td><td>Moderate \u4e2d\u7b49<\/td><td class=\"em\">Superior \u4f18\u5f02<\/td><\/tr>\n<tr><td>Dielectric Losses (Long Runs) \u4ecb\u8d28\u635f\u8017<\/td><td class=\"em\">Very low (preferred for long transmission)<\/td><td>Higher (limits very long AC transmission runs)<\/td><\/tr>\n<tr><td>Insulation Strippability \u7edd\u7f18\u53ef\u5265\u6027<\/td><td>Easier \u8f83\u5bb9\u6613<\/td><td>More difficult (risk of damaging insulation)<\/td><\/tr>\n<tr><td>Cost \u6210\u672c<\/td><td class=\"em\">Lower \u8f83\u4f4e<\/td><td>15\u201330% premium \u6ea2\u4ef715\u201330%<\/td><\/tr>\n<tr><td>Service Life (Wet Underground) \u4f7f\u7528\u5bff\u547d\uff08\u6f6e\u6e7f\u5730\u57cb\uff09<\/td><td>Good with TR-XLPE; standard XLPE may degrade<\/td><td class=\"em\">Excellent (30+ year field studies confirm reliability)<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<div class=\"bx info\">\n<strong>Research Highlight \u7814\u7a76\u8981\u70b9<\/strong>\nResearch by the EPR Cable Technology Consortium at the University of Connecticut has documented that EPR-insulated medium-voltage cables aged in wet underground environments for over 30 years maintained reliable AC and impulse breakdown strengths without developing a systematic failure mechanism. In contrast, both standard XLPE and TR-XLPE showed measurable impulse strength degradation during wet electrical aging, even when AC breakdown strength appeared stable. This suggests that EPR has a fundamental structural advantage in wet environments due to its amorphous morphology, which does not provide the crystalline pathways that water trees exploit in XLPE.<br>\n\uff08\u5eb7\u6d85\u72c4\u683c\u5927\u5b66 EPR \u7535\u7f06\u6280\u672f\u8054\u5408\u4f53\u7814\u7a76\u8868\u660e\uff0cEPR \u7edd\u7f18\u4e2d\u538b\u7535\u7f06\u5728\u6f6e\u6e7f\u5730\u4e0b\u73af\u5883\u8001\u5316 30 \u5e74\u4ee5\u4e0a\u4ecd\u4fdd\u6301\u53ef\u9760\u7684\u4ea4\u6d41\u548c\u51b2\u51fb\u51fb\u7a7f\u5f3a\u5ea6\u3002\u76f8\u6bd4\u4e4b\u4e0b\uff0c\u6807\u51c6 XLPE \u548c TR-XLPE \u5728\u6e7f\u7535\u8001\u5316\u4e2d\u51fa\u73b0\u53ef\u6d4b\u91cf\u7684\u51b2\u51fb\u5f3a\u5ea6\u9000\u5316\u3002\uff09\n<\/div>\n\n<!-- ===== 6. CORRECT APPROACH ===== -->\n<h2>6. The Correct Approach: When EPR Can Replace XLPE in Fixed HV <span class=\"cn\">\u6b63\u786e\u9014\u5f84\uff1a\u4f55\u65f6 EPR \u53ef\u66ff\u4ee3 XLPE \u7528\u4e8e\u56fa\u5b9a\u9ad8\u538b<\/span><\/h2>\n\n<p>If an engineer determines that EPR insulation offers genuine advantages for a specific fixed HV application \u2014 for example, a wet underground duct run, a water treatment facility, or an installation requiring extreme flexibility during pulling through conduit \u2014 the correct approach is <em>not<\/em> to re-purpose a Type 275 mining cable. Instead, the engineer should specify an EPR-insulated cable that is <strong>designed, manufactured, and type-tested to AS\/NZS 1429.1<\/strong> (or the equivalent IEC 60502.2). Such cables exist on the market and include individual metallic core screening, proper semiconductive screens rated for HV partial discharge performance, compacted conductors compatible with standard HV accessories, and PVC or HDPE outer sheaths with known thermal parameters for ampacity calculation.<\/p>\n<p class=\"cn-p\">\uff08\u82e5\u5de5\u7a0b\u5e08\u5224\u65ad EPR \u7edd\u7f18\u5728\u7279\u5b9a\u56fa\u5b9a\u9ad8\u538b\u5e94\u7528\u4e2d\u5177\u6709\u4f18\u52bf\uff08\u5982\u6f6e\u6e7f\u7ba1\u9053\u3001\u6c34\u5904\u7406\u8bbe\u65bd\uff09\uff0c\u6b63\u786e\u505a\u6cd5<em>\u4e0d\u662f<\/em>\u632a\u7528 Type 275 \u77ff\u7528\u7535\u7f06\uff0c\u800c\u662f\u6307\u5b9a\u6309 <strong>AS\/NZS 1429.1<\/strong>\uff08\u6216\u7b49\u6548 IEC 60502.2\uff09\u8bbe\u8ba1\u3001\u5236\u9020\u548c\u578b\u5f0f\u8bd5\u9a8c\u7684 EPR \u7edd\u7f18\u9ad8\u538b\u7535\u7f06\u3002\uff09<\/p>\n\n<div class=\"tw\">\n<table>\n<caption>Table 4 \u2014 Decision Matrix: Cable Selection for Fixed HV Applications \u88684 \u2014 \u56fa\u5b9a\u9ad8\u538b\u5e94\u7528\u7535\u7f06\u9009\u62e9\u51b3\u7b56\u77e9\u9635<\/caption>\n<thead><tr><th>Scenario \u573a\u666f<\/th><th>Recommended Insulation \u63a8\u8350\u7edd\u7f18<\/th><th>Standard \u6807\u51c6<\/th><th>Rationale \u7406\u7531<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Standard underground duct \/ direct burial (dry or low moisture)<\/td><td>XLPE (or TR-XLPE)<\/td><td>AS\/NZS 1429.1<\/td><td>Lower cost, lower dielectric losses, well-proven<\/td><\/tr>\n<tr><td>Wet underground \/ high water-table \/ submerged<\/td><td class=\"em\">EPR or TR-XLPE<\/td><td>AS\/NZS 1429.1<\/td><td>EPR: superior water-tree resistance; TR-XLPE: improved over std XLPE<\/td><\/tr>\n<tr><td>Tight-radius conduit pulls \/ congested installations<\/td><td class=\"em\">EPR<\/td><td>AS\/NZS 1429.1<\/td><td>Significantly more flexible; reduces installation labour<\/td><\/tr>\n<tr><td>Industrial chemical plant \/ refinery<\/td><td class=\"em\">EPR<\/td><td>AS\/NZS 1429.1<\/td><td>Superior chemical, ozone, and UV resistance<\/td><\/tr>\n<tr><td>Very long AC transmission runs (&gt; 10 km)<\/td><td class=\"em\">XLPE<\/td><td>AS\/NZS 1429.1<\/td><td>Lower dielectric losses (tan \u03b4) critical over long distance<\/td><\/tr>\n<tr><td>Cold-climate installation (&lt; \u221210 \u00b0C)<\/td><td class=\"em\">EPR<\/td><td>AS\/NZS 1429.1<\/td><td>Maintains flexibility at very low temperatures<\/td><\/tr>\n<tr><td>Mining \u2014 trailing\/reeling (mobile equipment)<\/td><td>EPR<\/td><td class=\"em\">AS\/NZS 1802<\/td><td>Type 275, 240, 241, 441 etc. \u2014 different cable category<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<!-- ===== 7. STANDARDS MAP ===== -->\n<h2>7. Standards Map: AS\/NZS 1802 vs. AS\/NZS 1429.1 <span class=\"cn\">\u6807\u51c6\u5bf9\u7167\uff1aAS\/NZS 1802 \u4e0e AS\/NZS 1429.1<\/span><\/h2>\n\n<div class=\"tw\">\n<table>\n<caption>Table 5 \u2014 Standards Comparison \u88685 \u2014 \u6807\u51c6\u5bf9\u6bd4<\/caption>\n<thead><tr><th>Attribute \u5c5e\u6027<\/th><th>AS\/NZS 1802:2003<\/th><th>AS\/NZS 1429.1:2006<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Title \u6807\u9898<\/td><td>Electric Cables \u2014 Rubber Insulated \u2014 For Working Voltages Up to and Including 0.6\/1 kV<\/td><td>Electric Cables \u2014 Polymeric Insulated \u2014 Part 1: For Working Voltages 1.9\/3.3 (3.6) kV to 19\/33 (36) kV<\/td><\/tr>\n<tr><td>International Basis \u56fd\u9645\u57fa\u7840<\/td><td>Australian\/NZ originated<\/td><td>Based on IEC 60502.2<\/td><\/tr>\n<tr><td>Voltage Range \u7535\u538b\u8303\u56f4<\/td><td>Up to 0.6\/1 (1.1) kV<\/td><td>1.9\/3.3 kV to 19\/33 kV<\/td><\/tr>\n<tr><td>Installation Category \u5b89\u88c5\u7c7b\u522b<\/td><td>Flexible \/ mobile \/ trailing<\/td><td>Fixed (buried, ducted, ladder, tray)<\/td><\/tr>\n<tr><td>Insulation Materials \u7edd\u7f18\u6750\u6599<\/td><td>EPR (R-EP-90)<\/td><td>XLPE or EPR<\/td><\/tr>\n<tr><td>Individual Core Screening \u5355\u82af\u5c4f\u853d<\/td><td>Not required<\/td><td>Required (metallic screen)<\/td><\/tr>\n<tr><td>PD Testing \u5c40\u653e\u6d4b\u8bd5<\/td><td>Not specified at HV level<\/td><td>Required (\u2264 10 pC at specified test voltage)<\/td><\/tr>\n<tr><td>Impulse Withstand (BIL) \u51b2\u51fb\u8010\u53d7<\/td><td>Not applicable at 1.1 kV<\/td><td>Required (e.g., 75 kV BIL for 6.6 kV cable)<\/td><\/tr>\n<tr><td>Type Test Regime \u578b\u5f0f\u8bd5\u9a8c\u4f53\u7cfb<\/td><td>Per AS\/NZS 1802 Appendix<\/td><td>Per AS\/NZS 1429.1 Section 4 (aligned with IEC 60502.2)<\/td><\/tr>\n<tr><td>Cable Types Covered \u6db5\u76d6\u7535\u7f06\u7c7b\u578b<\/td><td>Type 209, 210, 240, 241, 245, 275, 406, 440, 441, 450<\/td><td>Single-core &amp; three-core screened HV cables<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<!-- ===== 8. SUMMARY ===== -->\n<h2>8. Summary Verdict <span class=\"cn\">\u603b\u7ed3\u7ed3\u8bba<\/span><\/h2>\n\n<div class=\"verdict\">\n<h3>Engineering Verdict \u5de5\u7a0b\u7ed3\u8bba<\/h3>\n<p><strong>Type 275 (EPR\/CSP to AS\/NZS 1802) CANNOT be used to replace Olex Instalex (XLPE\/PVC to AS\/NZS 1429.1) for fixed HV transmission.<\/strong> The barriers are not merely regulatory \u2014 they are fundamental electrical engineering constraints involving voltage class, electric field screening, partial discharge performance, and termination compatibility.<\/p>\n<p style=\"margin-top:8px\"><strong>However<\/strong>, if your project requires the advantages of EPR insulation (water-tree resistance, flexibility, chemical resistance) in a fixed HV application, you <em>can<\/em> specify an EPR-insulated HV cable built to AS\/NZS 1429.1 or IEC 60502.2. This is a legitimate engineering choice that the standard explicitly supports.<\/p>\n<p class=\"cn-p\" style=\"margin-top:10px\">\uff08<strong>Type 275\uff08\u6309 AS\/NZS 1802\uff09\u4e0d\u80fd\u66ff\u4ee3 Olex Instalex\uff08\u6309 AS\/NZS 1429.1\uff09\u7528\u4e8e\u56fa\u5b9a\u9ad8\u538b\u4f20\u8f93\u3002<\/strong>\u969c\u788d\u4e0d\u4ec5\u662f\u6cd5\u89c4\u5c42\u9762\u7684\uff0c\u800c\u662f\u6d89\u53ca\u7535\u538b\u7b49\u7ea7\u3001\u7535\u573a\u5c4f\u853d\u3001\u5c40\u90e8\u653e\u7535\u548c\u7ec8\u7aef\u517c\u5bb9\u6027\u7b49\u6839\u672c\u7535\u6c14\u5de5\u7a0b\u7ea6\u675f\u3002\u4f46\u5982\u679c\u9879\u76ee\u786e\u9700 EPR \u7edd\u7f18\u4f18\u52bf\uff0c\u53ef\u6307\u5b9a\u6309 AS\/NZS 1429.1 \u6216 IEC 60502.2 \u5236\u9020\u7684 EPR \u7edd\u7f18\u9ad8\u538b\u7535\u7f06\u3002\uff09<\/p>\n<\/div>\n\n<div class=\"tw\">\n<table>\n<caption>Table 6 \u2014 Quick-Reference Substitutability Matrix \u88686 \u2014 \u53ef\u66ff\u6362\u6027\u901f\u67e5\u77e9\u9635<\/caption>\n<thead><tr><th>Proposed Substitution \u62df\u8bae\u66ff\u6362<\/th><th>Acceptable? \u662f\u5426\u53ef\u884c\uff1f<\/th><th>Reason \u539f\u56e0<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Type 275 (1.1 kV) \u2192 Olex Instalex HV (6.6\u201333 kV)<\/td><td style=\"color:var(--err-bd);font-weight:700\">\u2717 NO \u4e0d\u53ef<\/td><td>Wrong standard, wrong voltage, no individual screening, no PD testing<\/td><\/tr>\n<tr><td>EPR cable to AS\/NZS 1429.1 \u2192 XLPE cable to AS\/NZS 1429.1<\/td><td style=\"color:var(--ok-bd);font-weight:700\">\u2713 YES \u53ef\u884c<\/td><td>Both insulation types are explicitly covered by the same HV fixed-installation standard<\/td><\/tr>\n<tr><td>Olex Instalex HV (fixed) \u2192 Type 275 (mining trailing)<\/td><td style=\"color:var(--err-bd);font-weight:700\">\u2717 NO \u4e0d\u53ef<\/td><td>XLPE\/PVC rigid cable not suitable for mobile\/reeling mining applications<\/td><\/tr>\n<tr><td>Type 275 (EPR\/CSP) \u2192 Type 441 (EPR\/CSP, 3.3\u201322 kV, AS\/NZS 1802)<\/td><td style=\"color:var(--ok-bd);font-weight:700\">\u2713 Possible \u53ef\u80fd<\/td><td>Type 441 covers higher voltages within AS\/NZS 1802 for flexible mining use<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<div class=\"bx ok\">\n<strong>Feichun Cable Solutions \u98de\u7eaf\u7535\u7f06\u89e3\u51b3\u65b9\u6848<\/strong>\nAnhui Feichun Special Cable Co., Ltd. (\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8) manufactures both EPR-insulated and XLPE-insulated cables for medium-voltage and high-voltage fixed installations, as well as flexible mining cable types, to international standards including IEC 60502.2, AS\/NZS 1429.1, AS\/NZS 1802, and GB\/T 12706. Whether you need an XLPE-based equivalent to Olex Instalex or an EPR-insulated alternative engineered for wet and demanding environments, our technical team can assist with specification, cross-referencing, and sample supply.<br>\n\uff08\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8\u751f\u4ea7 EPR \u548c XLPE \u7edd\u7f18\u4e2d\/\u9ad8\u538b\u56fa\u5b9a\u5b89\u88c5\u7535\u7f06\u53ca\u67d4\u6027\u77ff\u7528\u7535\u7f06\uff0c\u7b26\u5408 IEC 60502.2\u3001AS\/NZS 1429.1\u3001AS\/NZS 1802 \u548c GB\/T 12706 \u7b49\u56fd\u9645\u6807\u51c6\u3002\u65e0\u8bba\u60a8\u9700\u8981\u4e0e Olex Instalex \u7b49\u6548\u7684 XLPE \u7535\u7f06\uff0c\u8fd8\u662f\u9002\u7528\u4e8e\u6f6e\u6e7f\u73af\u5883\u7684 EPR \u66ff\u4ee3\u65b9\u6848\uff0c\u6211\u4eec\u7684\u6280\u672f\u56e2\u961f\u5747\u53ef\u534f\u52a9\u9009\u578b\u3001\u4ea4\u53c9\u5bf9\u7167\u53ca\u6837\u54c1\u4f9b\u5e94\u3002\uff09\n<\/div>\n\n<!-- ===== REFERENCES ===== -->\n<div class=\"refs\">\n<h2>References &amp; Sources <span class=\"cn\">\u53c2\u8003\u6587\u732e\u4e0e\u6765\u6e90<\/span><\/h2>\n<ol class=\"rl\">\n<li>Standards Australia \/ Standards New Zealand \u2014 AS\/NZS 1429.1:2006: Electric Cables \u2014 Polymeric Insulated \u2014 Part 1: For Working Voltages 1.9\/3.3 (3.6) kV up to 19\/33 (36) kV. <a href=\"https:\/\/www.intertekinform.com\/en-au\/standards\/as-nzs-1429-1-2006-117704_saig_as_as_246416\/\" rel=\"nofollow noopener\" target=\"_blank\">intertekinform.com \u2014 AS\/NZS 1429.1<\/a><\/li>\n<li>Nexans Australia (Olex) \u2014 High Voltage XLPE Cable Catalogue. <a href=\"https:\/\/www.nexans.com.au\/en\/dam\/jcr:c332abc1-1637-4cbd-9fae-6a65a5485d97\/OLC12641_HighVoltageCat.pdf\" rel=\"nofollow noopener\" target=\"_blank\">nexans.com.au \u2014 HV Catalogue (PDF)<\/a><\/li>\n<li>Nexans Australia (Olex) \u2014 FAQ: Cable Ratings and Standards. <a href=\"https:\/\/www.nexans.com.au\/en\/tools-resources\/FAQ.html\" rel=\"nofollow noopener\" target=\"_blank\">nexans.com.au\/FAQ<\/a><\/li>\n<li>Voltimum Australia \u2014 Olex High Voltage Catalogue: AS\/NZS 1429.1 based on IEC 60502.2. <a href=\"https:\/\/www.voltimum.com.au\/articles\/olex-high-voltage-catalogue\" rel=\"nofollow noopener\" target=\"_blank\">voltimum.com.au<\/a><\/li>\n<li>Prysmian Australia \u2014 Type 275 1.1 kV Mining Cable Datasheet (AS\/NZS 1802). <a href=\"https:\/\/australia.prysmian.com\/sites\/australia.prysmian.com\/files\/media\/products\/type-275-1-1-kv.pdf\" rel=\"nofollow noopener\" target=\"_blank\">prysmian.com \u2014 Type 275 (PDF)<\/a><\/li>\n<li>Eland Cables \u2014 Type 275 Flexible Rubber Mining Cables. <a href=\"https:\/\/www.elandcables.com\/cables\/type-275-flexible-rubber-mining-cables\" rel=\"nofollow noopener\" target=\"_blank\">elandcables.com \u2014 Type 275<\/a><\/li>\n<li>Eland Cables \u2014 Type 240, Type 241, Type 245 Flexible Rubber Mining Cables. <a href=\"https:\/\/www.elandcables.com\/cables\/type-240-type-241-and-type-245-flexible-rubber-mining-cables\" rel=\"nofollow noopener\" target=\"_blank\">elandcables.com \u2014 Type 240\/241\/245<\/a><\/li>\n<li>Cable Distribution Services \u2014 Type 275 1.1 kV Product Listing. <a href=\"https:\/\/cabledistribution.com.au\/product\/type-275-1-1kv\/\" rel=\"nofollow noopener\" target=\"_blank\">cabledistribution.com.au<\/a><\/li>\n<li>EPR Cable Technology Consortium, University of Connecticut \u2014 EPR Cable Research: 30+ Years of Field Aging. <a href=\"https:\/\/eprcable.ims.uconn.edu\/epr-cables\/\" rel=\"nofollow noopener\" target=\"_blank\">eprcable.ims.uconn.edu<\/a><\/li>\n<li>Distributor Wire \u2014 EPR Cable: What Every Electrical Distributor Needs to Know (EPR vs XLPE). <a href=\"https:\/\/www.distributorwire.com\/blogs\/epr-vs-xlpe-insulation-electrical-distributor-guide\" rel=\"nofollow noopener\" target=\"_blank\">distributorwire.com<\/a><\/li>\n<li>Eng-Tips Forum \u2014 EPR vs. XLPE for MV Power Cables (Professional Engineering Discussion). <a href=\"https:\/\/www.eng-tips.com\/threads\/epr-vs-xlpe-for-mv-power-cables.89724\/\" rel=\"nofollow noopener\" target=\"_blank\">eng-tips.com<\/a><\/li>\n<li>Tratos Group \u2014 Cross-Linked Polyethylene (XLPE) Insulation. <a href=\"https:\/\/tratosgroup.com\/tratos-cable-academy\/polymeric-materials-for-cables-insulation\/crossed-linked-polyethylene-xlpe-cables\/\" rel=\"nofollow noopener\" target=\"_blank\">tratosgroup.com \u2014 XLPE<\/a><\/li>\n<li>Tratos Group \u2014 Chloro Sulphonated Polyethylene (CSP) Sheathing. <a href=\"https:\/\/tratosgroup.com\/tratos-cable-academy\/polymeric-materials-for-cables-insulation\/chloro-sulphonated-polyethylene-csp-cables\/\" rel=\"nofollow noopener\" target=\"_blank\">tratosgroup.com \u2014 CSP<\/a><\/li>\n<li>Eland Cables \u2014 FAQ: Benefits of CSPE Sheathed Cables. <a href=\"https:\/\/www.elandcables.com\/the-cable-lab\/faqs\/faq-what-are-the-benefits-of-cspe-sheathed-cables\" rel=\"nofollow noopener\" target=\"_blank\">elandcables.com \u2014 CSPE FAQ<\/a><\/li>\n<li>Anixter (WESCO) \u2014 Hypalon: Hype About Discontinuing (CSPE Technical Overview). <a href=\"https:\/\/www.anixter.com\/en_us\/resources\/literature\/wire-wisdom\/hypalon-hype-about-discontinuing.html\" rel=\"nofollow noopener\" target=\"_blank\">anixter.com \u2014 Hypalon<\/a><\/li>\n<li>Open Electrical Wiki \u2014 Cable Sheath Materials (PVC, CSP, XLPE, PE, CPE comparison). <a href=\"https:\/\/wiki.openelectrical.org\/index.php?title=Cable_Sheath_Materials\" rel=\"nofollow noopener\" target=\"_blank\">wiki.openelectrical.org<\/a><\/li>\n<li>Filipino Engineer \u2014 A Comparison Between XLPE and EPR as Insulating Materials for HV Cables. <a href=\"https:\/\/filipinoengineer.com\/blog\/2024\/07\/a-comparison-between-xlpe-and-epr-as-insulating-materials-for-hv-cables.html\" rel=\"nofollow noopener\" target=\"_blank\">filipinoengineer.com<\/a><\/li>\n<li>Electrical Engineering Portal \u2014 Comparison of Cable Insulating Materials (Bernstein). <a href=\"https:\/\/electrical-engineering-portal.com\/comparison-of-cable-insulating-materials\" rel=\"nofollow noopener\" target=\"_blank\">electrical-engineering-portal.com<\/a><\/li>\n<li>Power &amp; Cables \u2014 Olex Cable Joints (AS 1429.1 Cable Description Reference). <a href=\"https:\/\/www.powerandcables.com\/olex-cable-joints\/\" rel=\"nofollow noopener\" target=\"_blank\">powerandcables.com<\/a><\/li>\n<li>Wikipedia \u2014 Hypalon (Chlorosulfonated Polyethylene). <a href=\"https:\/\/en.wikipedia.org\/wiki\/Hypalon\" rel=\"nofollow noopener\" target=\"_blank\">en.wikipedia.org \u2014 Hypalon<\/a><\/li>\n<\/ol>\n<\/div>\n\n<!-- ===== CONTACT ===== -->\n<div class=\"ct\">\n<div class=\"t\">Contact Feichun Cable \u8054\u7cfb\u98de\u7eaf\u7535\u7f06<\/div>\n<div class=\"cr\">\n<span>\ud83c\udfed Anhui Feichun Special Cable Co., Ltd. \u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/span>\n<\/div>\n<div class=\"cr\" style=\"margin-top:5px\">\n<span>\u2709 <a href=\"mailto:tech@feichuncables.com\" rel=\"nofollow noopener\">tech@feichuncables.com<\/a><\/span>\n<span>\u2709 <a href=\"mailto:zihao.yang@feichuncables.com\" rel=\"nofollow noopener\">zihao.yang@feichuncables.com<\/a><\/span>\n<span>\u2709 <a href=\"mailto:ziyu.huang@feichuncables.com\" rel=\"nofollow noopener\">ziyu.huang@feichuncables.com<\/a><\/span>\n<\/div>\n<div class=\"cr\" style=\"margin-top:5px\">\n<span>\ud83d\udcf1 WhatsApp: <a href=\"https:\/\/wa.me\/8613855123218\" rel=\"nofollow noopener\" target=\"_blank\">+86 138-5512-3218<\/a><\/span>\n<\/div>\n<\/div>\n\n<\/article>\n\n<footer>\n<p>\u00a9 2026 Anhui Feichun Special Cable Co., Ltd. \u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8 \u2014 All rights reserved.<\/p>\n<p style=\"margin-top:4px\">This article is for technical reference only and does not constitute professional engineering advice. Cable selection for HV installations must be verified by a qualified electrical engineer in accordance with local regulations. \u672c\u6587\u4ec5\u4f9b\u6280\u672f\u53c2\u8003\uff0c\u4e0d\u6784\u6210\u4e13\u4e1a\u5de5\u7a0b\u5efa\u8bae\u3002\u9ad8\u538b\u5b89\u88c5\u7535\u7f06\u9009\u578b\u987b\u7531\u6301\u8bc1\u7535\u6c14\u5de5\u7a0b\u5e08\u6839\u636e\u5f53\u5730\u6cd5\u89c4\u9a8c\u8bc1\u3002<\/p>\n<\/footer>\n\n<\/div>\n<\/body>\n<\/html>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"This is a question that arises frequently on Australian and New Zealand mining and industrial project sites: a contractor has Olex Instalex XLPE\/PVC cable specified for a fixed high-voltage (HV) power transmission run, but Type 275 EPR\/CSP cable is readily available in stock or already on-site for mining equipment. Can one be substituted for the other?\n\uff08\u8fd9\u4e2a\u95ee\u9898\u7ecf\u5e38\u51fa\u73b0\u5728\u6fb3\u5927\u5229\u4e9a\u548c\u65b0\u897f\u5170\u7684\u77ff\u4e1a\u53ca\u5de5\u4e1a\u9879\u76ee\u73b0\u573a\uff1a\u8bbe\u8ba1\u6307\u5b9a\u4e86 Olex Instalex XLPE\/PVC \u7535\u7f06\u7528\u4e8e\u56fa\u5b9a\u9ad8\u538b\u4f20\u8f93\uff0c\u4f46\u73b0\u573a\u5df2\u6709 Type 275 EPR\/CSP \u77ff\u7528\u7535\u7f06\u5e93\u5b58\u3002\u4e24\u8005\u80fd\u5426\u4e92\u6362\uff1f\uff09","protected":false},"author":1,"featured_media":6632,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[222,66],"tags":[42047,42052,42074,42076,42050,42080,42073,42079,42077,42063,42068,42067,42046,42051,171,42062,152,107,42064,42057,139,214,42061,42048,42056,42069,42059,42072,42060,42065,42053,42055,42070,42075,42054,42071,42049,42078,10130,42081,42058,42066],"class_list":["post-6631","post","type-post","status-publish","format-standard","has-post-thumbnail","category-as-nzs-1802-reeling-cables-for-underground-mining","category-common-problems-encountered-in-cable-applications","tag-as-nzs-1429-1-xlpe-epr-cable-standard","tag-as-nzs-1802-mining-cable-standard","tag-cable-ampacity-calculation-as-nzs-3008-iec-60287","tag-cable-individual-core-screening-metallic-screen","tag-can-epr-replace-xlpe-fixed-installation","tag-chlorosulphonated-polyethylene-cable-jacket","tag-compacted-stranded-conductor-hv-cable","tag-copper-tape-screen-hv-cable-termination","tag-csp-cspe-hypalon-cable-sheath-properties","tag-dielectric-loss-tan-delta-epr-xlpe-comparison","tag-epr-cable-30-year-field-aging-reliability","tag-epr-cable-water-treatment-wet-environment","tag-epr-insulated-fixed-hv-cable-iec-60502-2","tag-epr-vs-xlpe-insulation-hv-cable","tag-explosion-proof-mining-cable","tag-feichun-special-cable-iec-60502","tag-heavy-duty-mining-cable","tag-heavy-duty-e-loader-mining-cable","tag-iec-60228-conductor-class-2-vs-class-5","tag-mining-cable-vs-fixed-installation-cable-difference","tag-mining-cables","tag-mining-power-cable","tag-mv-90-mv-105-cable-temperature-rating","tag-olex-instalex-xlpe-pvc-high-voltage-cable","tag-olex-nexans-australia-hv-cable","tag-partial-discharge-test-hv-cable-as-nzs-1429","tag-prysmian-type-275-mining-cable-datasheet","tag-pvc-sheath-vs-csp-sheath-cable","tag-tr-xlpe-tree-retardant-cable-comparison","tag-type-240-type-241-flexible-mining-cable","tag-type-275-1-1kv-shuttle-car-cable","tag-type-275-cable-epr-csp-specifications","tag-type-441-epr-mining-cable-3-3kv-6-6kv-11kv","tag-underground-coal-mine-trailing-cable-as-nzs-1802","tag-water-treeing-xlpe-vs-epr-cable","tag-xlpe-cable-direct-burial-underground-duct","tag-xlpe-insulated-medium-voltage-cable-11kv-22kv-33kv","tag--as-nzs-1429","tag-10130","tag--xlpe-","tag--as-nzs-1802","tag--xlpe-epr-","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/6631","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=6631"}],"version-history":[{"count":1,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/6631\/revisions"}],"predecessor-version":[{"id":6633,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/6631\/revisions\/6633"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/6632"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=6631"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=6631"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=6631"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}