{"id":6627,"date":"2026-02-09T13:58:05","date_gmt":"2026-02-09T05:58:05","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=6627"},"modified":"2026-02-09T13:58:07","modified_gmt":"2026-02-09T05:58:07","slug":"olex-versolex-vs-envirolex-understanding-the-shift-from-pvc-to-lszh-in-australian-tunnels","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/olex-versolex-vs-envirolex-understanding-the-shift-from-pvc-to-lszh-in-australian-tunnels\/","title":{"rendered":"Olex Versolex vs. Envirolex: Understanding the Shift from PVC to LSZH in Australian Tunnels"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Olex Versolex \u4e0e Envirolex \u5bf9\u6bd4\uff1a\u89e3\u8bfb\u6fb3\u5927\u5229\u4e9a\u96a7\u9053\u5de5\u7a0b\u4ece PVC \u5230 LSZH \u7535\u7f06\u7684\u8f6c\u578b<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"aea68d\" data-has-transparency=\"false\" style=\"--dominant-color: #aea68d;\" loading=\"lazy\" decoding=\"async\" width=\"784\" height=\"625\" sizes=\"auto, (max-width: 784px) 100vw, 784px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-776.avif\" alt=\"\" class=\"wp-image-6628 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-776.avif 784w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-776-300x239.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-776-768x612.avif 768w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-776-400x319.avif 400w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n<meta name=\"description\" content=\"Technical comparison of Olex Versolex (PVC) vs Envirolex (LSZH) cables for Australian tunnel infrastructure. AS\/NZS 5000.1, IEC 60754, IEC 61034, AS\/NZS 3013 compliance analysis by Anhui Feichun Special Cable Co., Ltd.\">\n<meta name=\"keywords\" content=\"Olex Versolex, Olex Envirolex, LSZH cable Australia, PVC vs LSZH tunnel, AS\/NZS 5000.1, low fire hazard cable, Feichun cables\">\n<title>Olex Versolex vs. Envirolex: PVC to LSZH Shift in Australian Tunnels | Feichun Cables<\/title>\n<style>\n\/* === RESET & VARIABLES === *\/\n*,*::before,*::after{box-sizing:border-box;margin:0;padding:0}\n:root{\n--bg:#ffffff;--bg2:#f5f7f9;--bg3:#e8ecf0;--text:#1a1a2e;--text2:#3a3a5a;--text3:#6b7280;\n--accent:#00539f;--accent2:#003870;--border:#d1d5db;\n--thead:#0c2d4a;--thead-c:#f0f4f8;--row-alt:#f5f8fb;\n--card-bd:1px solid #d1d5db;--link:#0a6abf;\n--tag-bg:#dbeafe;--tag-c:#1e40af;\n--warn-bg:#fffbeb;--warn-bd:#d97706;--warn-c:#78350f;\n--info-bg:#eff6ff;--info-bd:#2563eb;--info-c:#1e3a5f;\n--cmp-a:#e74c3c;--cmp-b:#27ae60;\n--cn-bg:#f9f9f5;--cn-c:#6b6b6b;--cn-bd:#d4d4c8;\n}\n@media(prefers-color-scheme:dark){:root{\n--bg:#0d1117;--bg2:#161b22;--bg3:#1c2333;--text:#e2e8f0;--text2:#b0bec5;--text3:#7b8794;\n--accent:#60a5fa;--accent2:#93c5fd;--border:#2d3748;\n--thead:#142a42;--thead-c:#d1e3f8;--row-alt:#131a24;\n--card-bd:1px solid #2d3748;--link:#60a5fa;\n--tag-bg:#1e3a5f;--tag-c:#93c5fd;\n--warn-bg:#2c1a00;--warn-bd:#d97706;--warn-c:#fcd34d;\n--info-bg:#0c1929;--info-bd:#60a5fa;--info-c:#93c5fd;\n--cmp-a:#f87171;--cmp-b:#4ade80;\n--cn-bg:#13161c;--cn-c:#8a8a8a;--cn-bd:#2d3748;\n}}\n\/* === BASE === *\/\nbody{font-family:-apple-system,BlinkMacSystemFont,\"Segoe UI\",Roboto,\"Noto Sans SC\",sans-serif;background:var(--bg);color:var(--text);line-height:1.78;font-size:16px}\na{color:var(--link);text-decoration:none}a:hover{text-decoration:underline}\n.wrap{max-width:940px;margin:0 auto;padding:0 20px}\n\/* === HEADER === *\/\n.hd{background:var(--bg2);border-bottom:3px solid var(--accent);padding:36px 0 28px}\n.hd-brand{font-size:12px;text-transform:uppercase;letter-spacing:.6px;color:var(--text3)}\n.hd h1{font-size:clamp(1.3rem,2.8vw,1.85rem);font-weight:700;line-height:1.35;margin:10px 0 6px;color:var(--text)}\n.hd-sub{font-size:14px;color:var(--text3)}\n\/* === CN NOTE === *\/\n.cn{background:var(--cn-bg);border-left:3px solid var(--cn-bd);padding:8px 14px;margin:8px 0;font-size:13.5px;color:var(--cn-c);border-radius:0 4px 4px 0}\n\/* === ARTICLE === *\/\narticle{padding:28px 0 40px}\nh2{font-size:1.3rem;font-weight:700;margin:34px 0 12px;padding-bottom:7px;border-bottom:2px solid var(--border);color:var(--text)}\nh3{font-size:1.05rem;font-weight:600;margin:22px 0 8px;color:var(--text)}\np{margin:0 0 15px;color:var(--text2)}\nsup{font-size:10.5px;color:var(--accent);font-weight:600}\n\/* === CALLOUTS === *\/\n.c-warn{background:var(--warn-bg);border-left:4px solid var(--warn-bd);padding:13px 16px;margin:18px 0;border-radius:0 4px 4px 0;color:var(--warn-c);font-size:14.5px}\n.c-info{background:var(--info-bg);border-left:4px solid var(--info-bd);padding:13px 16px;margin:18px 0;border-radius:0 4px 4px 0;color:var(--info-c);font-size:14.5px}\n.c-warn b,.c-info b{display:block;margin-bottom:3px}\n\/* === TABLES === *\/\n.tw{overflow-x:auto;-webkit-overflow-scrolling:touch;margin:16px 0 22px}\ntable{width:100%;border-collapse:collapse;font-size:13.5px}\ncaption{caption-side:top;text-align:left;font-weight:600;font-size:13.5px;color:var(--text3);padding-bottom:5px}\nthead th{background:var(--thead);color:var(--thead-c);padding:9px 11px;text-align:left;font-weight:600;white-space:nowrap;font-size:13px}\ntbody td{padding:8px 11px;border-bottom:1px solid var(--border);color:var(--text2);vertical-align:top}\ntbody tr:nth-child(even){background:var(--row-alt)}\ntbody tr:hover{background:var(--bg3)}\ntd.pvc{color:var(--cmp-a);font-weight:600}\ntd.lszh{color:var(--cmp-b);font-weight:600}\n\/* === REFS === *\/\n.refs{margin:16px 0;padding:0;list-style:none;counter-reset:r}\n.refs li{counter-increment:r;padding:5px 0 5px 30px;position:relative;font-size:13px;color:var(--text3);border-bottom:1px solid var(--border)}\n.refs li::before{content:\"[\" counter(r) \"]\";position:absolute;left:0;font-weight:700;color:var(--accent)}\n.refs a{word-break:break-all}\n\/* === CONTACT === *\/\n.ccard{background:var(--bg2);border:var(--card-bd);border-radius:6px;padding:20px 22px;margin:24px 0}\n.ccard h3{margin:0 0 12px;font-size:1rem}\n.cgrid{display:grid;grid-template-columns:repeat(auto-fit,minmax(250px,1fr));gap:12px}\n.ci{font-size:14px;color:var(--text2)}\n.ci span{display:block;font-size:11.5px;color:var(--text3);text-transform:uppercase;letter-spacing:.3px;margin-bottom:2px}\n.wab{display:inline-block;background:#25d366;color:#fff;padding:7px 16px;border-radius:4px;font-size:13.5px;font-weight:600;margin-top:8px}\n.wab:hover{background:#1da851;text-decoration:none;color:#fff}\n\/* === FOOTER === *\/\nfooter{background:var(--bg2);border-top:1px solid var(--border);padding:22px 0;text-align:center;font-size:12.5px;color:var(--text3)}\nfooter a{color:var(--accent)}\n\/* === RESPONSIVE === *\/\n@media(max-width:600px){\n.wrap{padding:0 14px}\nh1{font-size:1.2rem}\nh2{font-size:1.15rem}\ntable{font-size:12px}\nthead th,tbody td{padding:6px 7px}\n.cgrid{grid-template-columns:1fr}\n}\n<\/style>\n<\/head>\n<body>\n\n<!-- ===================== HEADER ===================== -->\n<header class=\"hd\">\n<div class=\"wrap\">\n<div class=\"hd-brand\">Anhui Feichun Special Cable Co., Ltd. \u2014 Technical Blog<\/div>\n<h1>Olex Versolex vs. Envirolex: Understanding the Shift from PVC to LSZH in Australian Tunnels<\/h1>\n<div class=\"cn\">\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8 \u6280\u672f\u535a\u5ba2 \u2014 Olex Versolex \u4e0e Envirolex \u5bf9\u6bd4\uff1a\u89e3\u8bfb\u6fb3\u5927\u5229\u4e9a\u96a7\u9053\u5de5\u7a0b\u4ece PVC \u5230 LSZH \u7535\u7f06\u7684\u8f6c\u578b<\/div>\n<div class=\"hd-sub\">Published by Feichun Technical Team &nbsp;|&nbsp; Fire Safety \u00b7 Cable Engineering \u00b7 Australian Standards &nbsp;|&nbsp; 2025<\/div>\n<\/div>\n<\/header>\n\n<!-- ===================== ARTICLE ===================== -->\n<article>\n<div class=\"wrap\">\n\n<!-- S1 INTRODUCTION -->\n<h2>1. Introduction: Why Australian Tunnels Are Abandoning PVC<br><small style=\"font-weight:400;font-size:13px;color:var(--cn-c)\">\u5f15\u8a00\uff1a\u4e3a\u4ec0\u4e48\u6fb3\u5927\u5229\u4e9a\u96a7\u9053\u6b63\u5728\u6dd8\u6c70 PVC \u7535\u7f06<\/small><\/h2>\n\n<p>Australia&#8217;s expanding infrastructure pipeline \u2014 including the Sydney Metro, Melbourne Metro Tunnel, WestConnex, and Cross River Rail \u2014 has placed fire safety at the centre of cable specification decisions. In enclosed environments such as tunnels, the combustion of conventional PVC-insulated cables releases dense smoke and toxic hydrogen chloride (HCl) gas, severely impeding evacuation and corroding surrounding equipment.<sup>[1][2]<\/sup><\/p>\n<div class=\"cn\">\u6fb3\u5927\u5229\u4e9a\u4e0d\u65ad\u6269\u5c55\u7684\u57fa\u7840\u8bbe\u65bd\u9879\u76ee\u2014\u2014\u5305\u62ec\u6089\u5c3c\u5730\u94c1\u3001\u58a8\u5c14\u672c\u5730\u94c1\u96a7\u9053\u3001WestConnex \u548c\u8de8\u6cb3\u94c1\u8def\u2014\u2014\u5df2\u5c06\u6d88\u9632\u5b89\u5168\u7f6e\u4e8e\u7535\u7f06\u9009\u578b\u51b3\u7b56\u7684\u6838\u5fc3\u3002\u5728\u96a7\u9053\u7b49\u5c01\u95ed\u73af\u5883\u4e2d\uff0c\u4f20\u7edf PVC \u7edd\u7f18\u7535\u7f06\u71c3\u70e7\u4f1a\u91ca\u653e\u6d53\u5bc6\u70df\u96fe\u548c\u6709\u6bd2\u7684\u6c2f\u5316\u6c22 (HCl) \u6c14\u4f53\uff0c\u4e25\u91cd\u963b\u788d\u4eba\u5458\u758f\u6563\u5e76\u8150\u8680\u5468\u56f4\u8bbe\u5907\u3002<\/div>\n\n<p>This shift is most clearly illustrated by two product lines from Nexans (Olex brand, Australia&#8217;s largest cable manufacturer): <strong>Versolex\u00ae<\/strong> \u2014 the long-established PVC-based flexible power cable, and <strong>Envirolex\u00ae<\/strong> \u2014 its Low Smoke Zero Halogen (LSZH) successor specifically designed for fire-sensitive environments. Understanding the technical, regulatory, and performance differences between these two ranges is essential for engineers specifying cables for tunnel and public infrastructure projects, and for international manufacturers seeking to supply LSZH-equivalent products to the Australian market.<sup>[3][4]<\/sup><\/p>\n<div class=\"cn\">\u8fd9\u4e00\u8f6c\u53d8\u6700\u6e05\u695a\u5730\u4f53\u73b0\u5728 Nexans\uff08Olex \u54c1\u724c\uff0c\u6fb3\u5927\u5229\u4e9a\u6700\u5927\u7684\u7535\u7f06\u5236\u9020\u5546\uff09\u7684\u4e24\u6761\u4ea7\u54c1\u7ebf\u4e0a\uff1a<strong>Versolex\u00ae<\/strong>\u2014\u2014\u957f\u671f\u4f7f\u7528\u7684 PVC \u57fa\u67d4\u6027\u7535\u529b\u7535\u7f06\uff0c\u4ee5\u53ca <strong>Envirolex\u00ae<\/strong>\u2014\u2014\u4e13\u4e3a\u706b\u707e\u654f\u611f\u73af\u5883\u8bbe\u8ba1\u7684\u4f4e\u70df\u65e0\u5364 (LSZH) \u66ff\u4ee3\u4ea7\u54c1\u3002\u4e86\u89e3\u8fd9\u4e24\u4e2a\u7cfb\u5217\u4e4b\u95f4\u7684\u6280\u672f\u3001\u6cd5\u89c4\u548c\u6027\u80fd\u5dee\u5f02\uff0c\u5bf9\u4e8e\u4e3a\u96a7\u9053\u548c\u516c\u5171\u57fa\u7840\u8bbe\u65bd\u9879\u76ee\u6307\u5b9a\u7535\u7f06\u7684\u5de5\u7a0b\u5e08\uff0c\u4ee5\u53ca\u5bfb\u6c42\u5411\u6fb3\u5927\u5229\u4e9a\u5e02\u573a\u4f9b\u5e94 LSZH \u7b49\u6548\u4ea7\u54c1\u7684\u56fd\u9645\u5236\u9020\u5546\u81f3\u5173\u91cd\u8981\u3002<\/div>\n\n<!-- S2 VERSOLEX -->\n<h2>2. Olex Versolex\u00ae: The PVC Benchmark<br><small style=\"font-weight:400;font-size:13px;color:var(--cn-c)\">Olex Versolex\u00ae\uff1aPVC \u57fa\u51c6\u4ea7\u54c1<\/small><\/h2>\n\n<p>Versolex\u00ae is Nexans&#8217; premium range of flexible power cables with PVC-based insulation (designated X-90 or V-90) and PVC sheathing. It has been the workhorse of Australian commercial and industrial electrical installations for decades, rated to 90 \u00b0C continuous conductor temperature at 0.6\/1 kV. Versolex\u00ae cables are manufactured to AS\/NZS 5000.1 and AS\/NZS 5000.2, and their PVC components meet the Best Practice Guidelines for PVC in the built environment.<sup>[3]<\/sup><\/p>\n<div class=\"cn\">Versolex\u00ae \u662f Nexans \u7684\u4f18\u8d28\u67d4\u6027\u7535\u529b\u7535\u7f06\u7cfb\u5217\uff0c\u91c7\u7528 PVC \u57fa\u7edd\u7f18\uff08\u6807\u8bb0\u4e3a X-90 \u6216 V-90\uff09\u548c PVC \u62a4\u5957\u3002\u6570\u5341\u5e74\u6765\uff0c\u5b83\u4e00\u76f4\u662f\u6fb3\u5927\u5229\u4e9a\u5546\u4e1a\u548c\u5de5\u4e1a\u7535\u6c14\u5b89\u88c5\u7684\u4e3b\u529b\u4ea7\u54c1\uff0c\u989d\u5b9a\u8fde\u7eed\u5bfc\u4f53\u6e29\u5ea6 90\u00b0C\uff0c\u7535\u538b 0.6\/1kV\u3002Versolex\u00ae \u7535\u7f06\u6309 AS\/NZS 5000.1 \u548c AS\/NZS 5000.2 \u6807\u51c6\u5236\u9020\u3002<\/div>\n\n<div class=\"tw\">\n<table>\n<caption>Table 1 \u2014 Olex Versolex\u00ae Key Specifications <span style=\"font-weight:400;color:var(--cn-c)\">| \u88681 \u2014 Olex Versolex\u00ae \u4e3b\u8981\u89c4\u683c<\/span><\/caption>\n<thead><tr><th>Parameter \u53c2\u6570<\/th><th>Versolex\u00ae Specification<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Insulation \u7edd\u7f18<\/td><td>X-90 (XLPE), V-90 (PVC), R-EP-90, R-CPE-90, R-HF-90, or R-CSP-90<\/td><\/tr>\n<tr><td>Sheath \u62a4\u5957<\/td><td>PVC (V-90)<\/td><\/tr>\n<tr><td>Voltage Rating \u989d\u5b9a\u7535\u538b<\/td><td>0.6\/1 kV<\/td><\/tr>\n<tr><td>Max. Conductor Temperature \u6700\u9ad8\u5bfc\u4f53\u6e29\u5ea6<\/td><td>90 \u00b0C continuous<\/td><\/tr>\n<tr><td>Conductor \u5bfc\u4f53<\/td><td>Flexible stranded copper, Class 5 \u67d4\u6027\u7ede\u5408\u94dc\uff0c5\u7c7b<\/td><\/tr>\n<tr><td>Ambient Reference \u53c2\u8003\u73af\u5883\u6e29\u5ea6<\/td><td>40 \u00b0C (in air) \/ 25 \u00b0C (in ground)<\/td><\/tr>\n<tr><td>Standards \u6807\u51c6<\/td><td>AS\/NZS 5000.1, AS\/NZS 5000.2<\/td><\/tr>\n<tr><td>Halogen Content \u5364\u7d20\u542b\u91cf<\/td><td class=\"pvc\">Contains halogens (Cl in PVC) \u542b\u5364\u7d20<\/td><\/tr>\n<tr><td>Available Sizes \u53ef\u7528\u89c4\u683c<\/td><td>1.5 mm\u00b2 \u2013 630 mm\u00b2 (single core); multicore variants<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<div class=\"c-warn\">\n<b>\u26a0 PVC Fire Hazard Limitation PVC \u706b\u707e\u5371\u5bb3\u9650\u5236<\/b>\nNexans itself notes that Versolex\u00ae is available in a Low Smoke Zero Halogen variant \u2014 &#8220;See ENVIROLEX &#8211; Low Fire Hazard&#8221; \u2014 and explicitly recommends Envirolex\u00ae for systems intended to operate continuously at maximum temperature, acknowledging that the LSZH version is the preferred solution for fire-sensitive installations.<sup>[3]<\/sup><br>\n<span style=\"font-size:13px;\">Nexans \u81ea\u8eab\u4e5f\u6307\u51fa Versolex\u00ae \u6709\u4f4e\u70df\u65e0\u5364\u7248\u672c\u2014\u2014&#8221;\u53c2\u89c1 ENVIROLEX &#8211; \u4f4e\u706b\u707e\u5371\u5bb3&#8221;\u2014\u2014\u5e76\u660e\u786e\u63a8\u8350 Envirolex\u00ae \u7528\u4e8e\u4ee5\u6700\u9ad8\u6e29\u5ea6\u8fde\u7eed\u8fd0\u884c\u7684\u7cfb\u7edf\uff0c\u627f\u8ba4 LSZH \u7248\u672c\u662f\u706b\u707e\u654f\u611f\u5b89\u88c5\u7684\u9996\u9009\u65b9\u6848\u3002<\/span>\n<\/div>\n\n<!-- S3 ENVIROLEX -->\n<h2>3. Olex Envirolex\u00ae: The LSZH Alternative<br><small style=\"font-weight:400;font-size:13px;color:var(--cn-c)\">Olex Envirolex\u00ae\uff1aLSZH \u66ff\u4ee3\u65b9\u6848<\/small><\/h2>\n\n<p>Envirolex\u00ae is part of the Nexans Fire Safety Offer, designed as a direct LSZH replacement for Versolex\u00ae. It is PVC-free, uses X-HF-110 (cross-linked halogen-free) insulation and HFS-110-TP (halogen-free thermoplastic) sheathing, and is rated to 110 \u00b0C continuous \u2014 a 20 \u00b0C increase over Versolex\u00ae. This higher thermal rating delivers a meaningful ampacity advantage in constrained cable routes typical of tunnels.<sup>[4][5][6]<\/sup><\/p>\n<div class=\"cn\">Envirolex\u00ae \u662f Nexans \u6d88\u9632\u5b89\u5168\u4ea7\u54c1\u7cfb\u5217\u7684\u4e00\u90e8\u5206\uff0c\u8bbe\u8ba1\u4e3a Versolex\u00ae \u7684\u76f4\u63a5 LSZH \u66ff\u4ee3\u54c1\u3002\u5b83\u4e0d\u542b PVC\uff0c\u91c7\u7528 X-HF-110\uff08\u4ea4\u8054\u65e0\u5364\uff09\u7edd\u7f18\u548c HFS-110-TP\uff08\u65e0\u5364\u70ed\u5851\u6027\uff09\u62a4\u5957\uff0c\u989d\u5b9a\u8fde\u7eed\u6e29\u5ea6 110\u00b0C\u2014\u2014\u6bd4 Versolex\u00ae \u9ad8\u51fa 20\u00b0C\u3002\u66f4\u9ad8\u7684\u70ed\u989d\u5b9a\u503c\u5728\u96a7\u9053\u4e2d\u53d7\u9650\u7684\u7535\u7f06\u8def\u7531\u4e2d\u63d0\u4f9b\u4e86\u6709\u610f\u4e49\u7684\u8f7d\u6d41\u91cf\u4f18\u52bf\u3002<\/div>\n\n<div class=\"tw\">\n<table>\n<caption>Table 2 \u2014 Olex Envirolex\u00ae Key Specifications <span style=\"font-weight:400;color:var(--cn-c)\">| \u88682 \u2014 Olex Envirolex\u00ae \u4e3b\u8981\u89c4\u683c<\/span><\/caption>\n<thead><tr><th>Parameter \u53c2\u6570<\/th><th>Envirolex\u00ae Specification<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Insulation \u7edd\u7f18<\/td><td>X-HF-110, R-HF-110, or R-E-110 (all halogen-free)<\/td><\/tr>\n<tr><td>Sheath \u62a4\u5957<\/td><td>HFS-110-TP (halogen-free thermoplastic)<\/td><\/tr>\n<tr><td>Voltage Rating \u989d\u5b9a\u7535\u538b<\/td><td>0.6\/1 kV<\/td><\/tr>\n<tr><td>Max. Conductor Temperature \u6700\u9ad8\u5bfc\u4f53\u6e29\u5ea6<\/td><td>110 \u00b0C continuous<\/td><\/tr>\n<tr><td>Conductor \u5bfc\u4f53<\/td><td>Flexible stranded copper, Class 5 &amp; 6<\/td><\/tr>\n<tr><td>Ambient Reference \u53c2\u8003\u73af\u5883\u6e29\u5ea6<\/td><td>40 \u00b0C (in air) \/ 25 \u00b0C (in ground)<\/td><\/tr>\n<tr><td>Standards \u6807\u51c6<\/td><td>AS\/NZS 5000.1, AS\/NZS 4507<\/td><\/tr>\n<tr><td>Flame Propagation \u706b\u7130\u8513\u5ef6<\/td><td>IEC 60332-3 Category A (bunched cable test)<\/td><\/tr>\n<tr><td>Halogen Content \u5364\u7d20\u542b\u91cf<\/td><td class=\"lszh\">Zero halogen \u2014 PVC-free \u96f6\u5364\u7d20\u2014\u2014\u65e0PVC<\/td><\/tr>\n<tr><td>Fire Classification \u9632\u706b\u5206\u7c7b<\/td><td>RHE-3 to AS\/NZS 4507<\/td><\/tr>\n<tr><td>Certifications \u8ba4\u8bc1<\/td><td>Red List Free, Declare Labelled, Green Star<\/td><\/tr>\n<tr><td>Available Sizes \u53ef\u7528\u89c4\u683c<\/td><td>1.5 mm\u00b2 \u2013 630 mm\u00b2 (single core); 2C+E, 3C+E, 4C+E multicore<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<!-- S4 HEAD-TO-HEAD -->\n<h2>4. Head-to-Head: Versolex\u00ae (PVC) vs. Envirolex\u00ae (LSZH)<br><small style=\"font-weight:400;font-size:13px;color:var(--cn-c)\">\u6b63\u9762\u5bf9\u6bd4\uff1aVersolex\u00ae\uff08PVC\uff09vs. Envirolex\u00ae\uff08LSZH\uff09<\/small><\/h2>\n\n<p>The following comparison table consolidates every specification point that tunnel engineers and procurement teams need to evaluate when making the PVC-to-LSZH transition decision. The differences go far beyond materials \u2014 they encompass thermal performance, fire behaviour, environmental credentials, and long-term total cost of ownership.<\/p>\n<div class=\"cn\">\u4ee5\u4e0b\u5bf9\u6bd4\u8868\u6c47\u603b\u4e86\u96a7\u9053\u5de5\u7a0b\u5e08\u548c\u91c7\u8d2d\u56e2\u961f\u5728\u505a\u51fa PVC \u5230 LSZH \u8f6c\u6362\u51b3\u7b56\u65f6\u9700\u8981\u8bc4\u4f30\u7684\u6bcf\u4e2a\u89c4\u683c\u8981\u70b9\u3002\u5dee\u5f02\u8fdc\u4e0d\u6b62\u6750\u6599\u2014\u2014\u8fd8\u6db5\u76d6\u4e86\u70ed\u6027\u80fd\u3001\u706b\u707e\u884c\u4e3a\u3001\u73af\u4fdd\u8d44\u8d28\u548c\u957f\u671f\u603b\u62e5\u6709\u6210\u672c\u3002<\/div>\n\n<div class=\"tw\">\n<table>\n<caption>Table 3 \u2014 Comprehensive Technical Comparison <span style=\"font-weight:400;color:var(--cn-c)\">| \u88683 \u2014 \u5168\u9762\u6280\u672f\u5bf9\u6bd4<\/span><\/caption>\n<thead><tr><th>Parameter \u53c2\u6570<\/th><th style=\"color:#f87171\">Versolex\u00ae (PVC)<\/th><th style=\"color:#4ade80\">Envirolex\u00ae (LSZH)<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Insulation Type \u7edd\u7f18\u7c7b\u578b<\/td><td class=\"pvc\">X-90 \/ V-90 (contains PVC)<\/td><td class=\"lszh\">X-HF-110 (halogen-free XLPE)<\/td><\/tr>\n<tr><td>Sheath Material \u62a4\u5957\u6750\u6599<\/td><td class=\"pvc\">PVC (V-90)<\/td><td class=\"lszh\">HFS-110-TP (halogen-free thermoplastic)<\/td><\/tr>\n<tr><td>Max. Conductor Temp \u6700\u9ad8\u5bfc\u4f53\u6e29\u5ea6<\/td><td>90 \u00b0C<\/td><td><strong>110 \u00b0C (+22%)<\/strong><\/td><\/tr>\n<tr><td>Voltage Rating \u989d\u5b9a\u7535\u538b<\/td><td>0.6\/1 kV<\/td><td>0.6\/1 kV<\/td><\/tr>\n<tr><td>Smoke Emission \u70df\u96fe\u6392\u653e<\/td><td class=\"pvc\">High \u2014 dense black smoke \u9ad8\u2014\u2014\u6d53\u5bc6\u9ed1\u70df<\/td><td class=\"lszh\">Very low \u2014 \u226560% light transmittance (IEC 61034)<\/td><\/tr>\n<tr><td>Halogen Gas Release \u5364\u7d20\u6c14\u4f53\u91ca\u653e<\/td><td class=\"pvc\">HCl released (toxic, corrosive) \u91ca\u653eHCl\uff08\u6709\u6bd2\u8150\u8680\u6027\uff09<\/td><td class=\"lszh\">pH \u2265 4.3, conductivity \u2264 10 \u00b5S\/mm (IEC 60754)<\/td><\/tr>\n<tr><td>Flame Propagation Test \u706b\u7130\u8513\u5ef6\u6d4b\u8bd5<\/td><td>IEC 60332-1 (single cable)<\/td><td><strong>IEC 60332-3 Cat A<\/strong> (bunched \u2014 most stringent \u6700\u4e25\u683c)<\/td><\/tr>\n<tr><td>Primary Standard \u4e3b\u8981\u6807\u51c6<\/td><td>AS\/NZS 5000.1 &amp; 5000.2<\/td><td>AS\/NZS 5000.1, AS\/NZS 4507<\/td><\/tr>\n<tr><td>Tunnel Suitability \u96a7\u9053\u9002\u7528\u6027<\/td><td class=\"pvc\">Not recommended \u4e0d\u63a8\u8350<\/td><td class=\"lszh\">Specifically designed for tunnels &amp; enclosed spaces<\/td><\/tr>\n<tr><td>Corrosion Risk \u8150\u8680\u98ce\u9669<\/td><td class=\"pvc\">High \u2014 HCl corrodes switchgear, metal structures<\/td><td class=\"lszh\">Negligible \u2014 non-corrosive combustion gases<\/td><\/tr>\n<tr><td>Environmental Certs \u73af\u4fdd\u8ba4\u8bc1<\/td><td>PVC Best Practice compliant<\/td><td>Red List Free, Declare Label, Green Star<\/td><\/tr>\n<tr><td>Relative Material Cost \u76f8\u5bf9\u6750\u6599\u6210\u672c<\/td><td>Baseline (1.0\u00d7)<\/td><td>~1.15\u00d7 \u2013 1.30\u00d7 (higher upfront \u524d\u671f\u8f83\u9ad8)<\/td><\/tr>\n<tr><td>Total Cost of Ownership \u603b\u62e5\u6709\u6210\u672c<\/td><td>Higher when fire risk factored \u8003\u8651\u706b\u707e\u98ce\u9669\u540e\u66f4\u9ad8<\/td><td class=\"lszh\">Lower over asset lifecycle \u8d44\u4ea7\u5168\u751f\u547d\u5468\u671f\u66f4\u4f4e<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<!-- S5 REGULATORY -->\n<h2>5. Australian Regulatory Framework Driving the LSZH Shift<br><small style=\"font-weight:400;font-size:13px;color:var(--cn-c)\">\u63a8\u52a8 LSZH \u8f6c\u578b\u7684\u6fb3\u5927\u5229\u4e9a\u6cd5\u89c4\u6846\u67b6<\/small><\/h2>\n\n<p>The transition from PVC to LSZH in Australian tunnels is not voluntary \u2014 it is driven by an increasingly prescriptive regulatory environment. AS\/NZS 3013 classifies the fire and mechanical performance of wiring system elements; AS\/NZS 3000 (the Wiring Rules) mandates compliance with fire safety requirements; and AS\/NZS 1670.3 requires low-smoke halogen-free cables in rail transit and underground facilities.<sup>[7][8][9]<\/sup> Infrastructure authorities such as Transport for NSW and the Victorian Department of Transport mandate LSZH cables in all new tunnel projects through their design standards.<\/p>\n<div class=\"cn\">\u6fb3\u5927\u5229\u4e9a\u96a7\u9053\u4e2d\u4ece PVC \u5230 LSZH \u7684\u8f6c\u6362\u5e76\u975e\u81ea\u613f\u2014\u2014\u5b83\u7531\u65e5\u76ca\u4e25\u683c\u7684\u6cd5\u89c4\u73af\u5883\u63a8\u52a8\u3002AS\/NZS 3013 \u5bf9\u5e03\u7ebf\u7cfb\u7edf\u5143\u4ef6\u7684\u9632\u706b\u548c\u673a\u68b0\u6027\u80fd\u8fdb\u884c\u5206\u7c7b\uff1bAS\/NZS 3000\uff08\u5e03\u7ebf\u89c4\u5219\uff09\u8981\u6c42\u9075\u5b88\u6d88\u9632\u5b89\u5168\u8981\u6c42\uff1bAS\/NZS 1670.3 \u8981\u6c42\u5728\u8f68\u9053\u4ea4\u901a\u548c\u5730\u4e0b\u8bbe\u65bd\u4e2d\u4f7f\u7528\u4f4e\u70df\u65e0\u5364\u7535\u7f06\u3002\u4ea4\u901a\u57fa\u7840\u8bbe\u65bd\u4e3b\u7ba1\u90e8\u95e8\u901a\u8fc7\u5176\u8bbe\u8ba1\u6807\u51c6\u5728\u6240\u6709\u65b0\u96a7\u9053\u9879\u76ee\u4e2d\u5f3a\u5236\u4f7f\u7528 LSZH \u7535\u7f06\u3002<\/div>\n\n<div class=\"tw\">\n<table>\n<caption>Table 4 \u2014 Key Australian &amp; International Standards for Tunnel Cable Selection <span style=\"font-weight:400;color:var(--cn-c)\">| \u88684 \u2014 \u96a7\u9053\u7535\u7f06\u9009\u578b\u5173\u952e\u6807\u51c6<\/span><\/caption>\n<thead><tr><th>Standard \u6807\u51c6<\/th><th>Scope \u9002\u7528\u8303\u56f4<\/th><th>PVC (Versolex)<\/th><th>LSZH (Envirolex)<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>AS\/NZS 5000.1<\/td><td>LV power cable construction \u4f4e\u538b\u7535\u529b\u7535\u7f06\u6784\u9020<\/td><td>\u2713 Compliant<\/td><td>\u2713 Compliant<\/td><\/tr>\n<tr><td>AS\/NZS 4507<\/td><td>Fire-performance rated cables \u9632\u706b\u6027\u80fd\u989d\u5b9a\u7535\u7f06<\/td><td class=\"pvc\">\u2717 Not rated<\/td><td class=\"lszh\">\u2713 RHE-3<\/td><\/tr>\n<tr><td>AS\/NZS 3013<\/td><td>Fire &amp; mechanical performance of wiring \u5e03\u7ebf\u9632\u706b\u548c\u673a\u68b0\u6027\u80fd<\/td><td>Limited compliance<\/td><td class=\"lszh\">\u2713 Full compliance<\/td><\/tr>\n<tr><td>AS\/NZS 1670.3<\/td><td>Fire detection &amp; alarm \u2014 cabling \u706b\u707e\u63a2\u6d4b\u62a5\u8b66\u5e03\u7ebf<\/td><td class=\"pvc\">\u2717 Not permitted in tunnels<\/td><td class=\"lszh\">\u2713 Mandatory compliant<\/td><\/tr>\n<tr><td>AS\/NZS 3000<\/td><td>Wiring Rules \u5e03\u7ebf\u89c4\u5219<\/td><td>\u2713 General use<\/td><td>\u2713 General + fire-critical<\/td><\/tr>\n<tr><td>IEC 60332-3<\/td><td>Flame propagation \u2014 bunched cables \u6210\u675f\u7535\u7f06\u706b\u7130\u8513\u5ef6<\/td><td>Single cable only<\/td><td class=\"lszh\">\u2713 Cat A (most stringent)<\/td><\/tr>\n<tr><td>IEC 60754-1\/-2<\/td><td>Halogen acid gas emission \u5364\u7d20\u9178\u6027\u6c14\u4f53\u6392\u653e<\/td><td class=\"pvc\">Fails \u2014 HCl &gt; 5 mg\/g<\/td><td class=\"lszh\">\u2713 pH \u2265 4.3<\/td><\/tr>\n<tr><td>IEC 61034-2<\/td><td>Smoke density measurement \u70df\u96fe\u5bc6\u5ea6\u6d4b\u91cf<\/td><td class=\"pvc\">Fails \u2014 low transmittance<\/td><td class=\"lszh\">\u2713 \u2265 60% light transmittance<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<!-- S6 FIRE SCIENCE -->\n<h2>6. The Science: PVC vs. LSZH Combustion Behaviour<br><small style=\"font-weight:400;font-size:13px;color:var(--cn-c)\">\u79d1\u5b66\u89e3\u6790\uff1aPVC \u4e0e LSZH \u71c3\u70e7\u884c\u4e3a\u5bf9\u6bd4<\/small><\/h2>\n\n<p>When PVC burns, the chlorine atoms in polyvinyl chloride react with hydrogen to produce hydrogen chloride (HCl) gas. In a tunnel fire scenario, this gas creates a highly corrosive acidic atmosphere that damages electrical switchgear, ventilation systems, structural steel, and signalling equipment \u2014 often causing secondary damage exceeding the original fire cost. The dense black smoke produced drops visibility to near zero within minutes, critically impeding evacuation. In contrast, LSZH compounds are formulated from halogen-free polyolefin-based materials that release minimal, non-toxic combustion products and maintain light transmittance above 60% during the IEC 61034 smoke density test.<sup>[1][10][11]<\/sup><\/p>\n<div class=\"cn\">\u5f53 PVC \u71c3\u70e7\u65f6\uff0c\u805a\u6c2f\u4e59\u70ef\u4e2d\u7684\u6c2f\u539f\u5b50\u4e0e\u6c22\u53cd\u5e94\u4ea7\u751f\u6c2f\u5316\u6c22 (HCl) \u6c14\u4f53\u3002\u5728\u96a7\u9053\u706b\u707e\u573a\u666f\u4e2d\uff0c\u8be5\u6c14\u4f53\u4ea7\u751f\u9ad8\u8150\u8680\u6027\u9178\u6027\u73af\u5883\uff0c\u635f\u574f\u7535\u6c14\u5f00\u5173\u8bbe\u5907\u3001\u901a\u98ce\u7cfb\u7edf\u3001\u7ed3\u6784\u94a2\u548c\u4fe1\u53f7\u8bbe\u5907\u2014\u2014\u901a\u5e38\u9020\u6210\u7684\u4e8c\u6b21\u635f\u5bb3\u8d85\u8fc7\u539f\u59cb\u706b\u707e\u6210\u672c\u3002\u4ea7\u751f\u7684\u6d53\u5bc6\u9ed1\u70df\u5728\u51e0\u5206\u949f\u5185\u5c06\u80fd\u89c1\u5ea6\u964d\u81f3\u63a5\u8fd1\u96f6\uff0c\u4e25\u91cd\u963b\u788d\u758f\u6563\u3002\u76f8\u6bd4\u4e4b\u4e0b\uff0cLSZH \u5316\u5408\u7269\u7531\u65e0\u5364\u805a\u70ef\u70c3\u57fa\u6750\u6599\u914d\u5236\uff0c\u71c3\u70e7\u4ea7\u7269\u6781\u5c11\u4e14\u65e0\u6bd2\uff0c\u5728 IEC 61034 \u70df\u96fe\u5bc6\u5ea6\u6d4b\u8bd5\u4e2d\u4fdd\u6301 60% \u4ee5\u4e0a\u7684\u900f\u5149\u7387\u3002<\/div>\n\n<div class=\"tw\">\n<table>\n<caption>Table 5 \u2014 Fire Behaviour Comparison: PVC vs. LSZH <span style=\"font-weight:400;color:var(--cn-c)\">| \u88685 \u2014 \u706b\u707e\u884c\u4e3a\u5bf9\u6bd4<\/span><\/caption>\n<thead><tr><th>Fire Parameter \u706b\u707e\u53c2\u6570<\/th><th style=\"color:#f87171\">PVC Cable<\/th><th style=\"color:#4ade80\">LSZH Cable<\/th><th>Test Standard<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Smoke Density \u70df\u96fe\u5bc6\u5ea6<\/td><td class=\"pvc\">Very high \u975e\u5e38\u9ad8<\/td><td class=\"lszh\">&lt; 20% of PVC levels<\/td><td>IEC 61034-2<\/td><\/tr>\n<tr><td>Light Transmittance \u900f\u5149\u7387<\/td><td class=\"pvc\">&lt; 30% (rapid obscuration)<\/td><td class=\"lszh\">\u2265 60\u201380%<\/td><td>IEC 61034-2<\/td><\/tr>\n<tr><td>HCl Gas Release \u6c2f\u5316\u6c22\u91ca\u653e<\/td><td class=\"pvc\">Significant (&gt; 150 mg\/g HCl)<\/td><td class=\"lszh\">\u2264 5 mg\/g halogen acid<\/td><td>IEC 60754-1<\/td><\/tr>\n<tr><td>Gas Acidity (pH) \u6c14\u4f53\u9178\u5ea6<\/td><td class=\"pvc\">pH &lt; 2 (highly acidic)<\/td><td class=\"lszh\">pH \u2265 4.3<\/td><td>IEC 60754-2<\/td><\/tr>\n<tr><td>Gas Conductivity \u6c14\u4f53\u5bfc\u7535\u6027<\/td><td class=\"pvc\">&gt; 100 \u00b5S\/mm<\/td><td class=\"lszh\">\u2264 10 \u00b5S\/mm<\/td><td>IEC 60754-2<\/td><\/tr>\n<tr><td>Flame Propagation \u706b\u7130\u8513\u5ef6<\/td><td class=\"pvc\">Self-extinguishing (single) \u81ea\u7184\uff08\u5355\u6839\uff09<\/td><td class=\"lszh\">Cat A compliant (bunched) \u6210\u675f\u5408\u683c<\/td><td>IEC 60332-3-22<\/td><\/tr>\n<tr><td>Equipment Corrosion \u8bbe\u5907\u8150\u8680<\/td><td class=\"pvc\">Severe \u4e25\u91cd<\/td><td class=\"lszh\">Negligible \u53ef\u5ffd\u7565<\/td><td>\u2014<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<!-- S7 ELECTRICAL DATA -->\n<h2>7. Electrical Performance Data: Envirolex\u00ae Single Core<br><small style=\"font-weight:400;font-size:13px;color:var(--cn-c)\">\u7535\u6c14\u6027\u80fd\u6570\u636e\uff1aEnvirolex\u00ae \u5355\u82af<\/small><\/h2>\n\n<p>The following table provides representative DC resistance and dimensional data for the Envirolex\u00ae flexible single-core range, illustrating that the LSZH construction maintains full electrical performance equivalence to PVC-insulated alternatives while delivering improved thermal capacity.<\/p>\n<div class=\"cn\">\u4e0b\u8868\u63d0\u4f9b\u4e86 Envirolex\u00ae \u67d4\u6027\u5355\u82af\u7cfb\u5217\u7684\u4ee3\u8868\u6027\u76f4\u6d41\u7535\u963b\u548c\u5c3a\u5bf8\u6570\u636e\uff0c\u8868\u660e LSZH \u7ed3\u6784\u5728\u4fdd\u6301\u4e0e PVC \u7edd\u7f18\u66ff\u4ee3\u54c1\u5b8c\u5168\u7b49\u6548\u7684\u7535\u6c14\u6027\u80fd\u7684\u540c\u65f6\uff0c\u63d0\u4f9b\u4e86\u66f4\u9ad8\u7684\u70ed\u5bb9\u91cf\u3002<\/div>\n\n<div class=\"tw\">\n<table>\n<caption>Table 6 \u2014 Envirolex\u00ae Single Core 0.6\/1 kV X-HF-110, Representative Data<sup>[5][6]<\/sup> <span style=\"font-weight:400;color:var(--cn-c)\">| \u88686 \u2014 Envirolex\u00ae \u5355\u82af\u4ee3\u8868\u6027\u6570\u636e<\/span><\/caption>\n<thead><tr><th>Size (mm\u00b2)<\/th><th>Max. DC Resistance 20 \u00b0C (\u03a9\/km)<\/th><th>Nom. OD (mm)<\/th><th>Approx. Mass (kg\/100m)<\/th><th>Product Code<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>10<\/td><td>1.91<\/td><td>8.6<\/td><td>16<\/td><td>BZHX01AA001<\/td><\/tr>\n<tr><td>16<\/td><td>1.21<\/td><td>9.8<\/td><td>23<\/td><td>BZHX02AA001<\/td><\/tr>\n<tr><td>25<\/td><td>0.78<\/td><td>11.3<\/td><td>31<\/td><td>BZHX03AA001<\/td><\/tr>\n<tr><td>35<\/td><td>0.554<\/td><td>12.5<\/td><td>40<\/td><td>BZHX04AA001<\/td><\/tr>\n<tr><td>50<\/td><td>0.386<\/td><td>14.3<\/td><td>56<\/td><td>BZHX05AA001<\/td><\/tr>\n<tr><td>70<\/td><td>0.272<\/td><td>16.2<\/td><td>75<\/td><td>BZHX06AA001<\/td><\/tr>\n<tr><td>95<\/td><td>0.206<\/td><td>18.1<\/td><td>98<\/td><td>BZHX07AA001<\/td><\/tr>\n<tr><td>120<\/td><td>0.161<\/td><td>20.4<\/td><td>113<\/td><td>BZHE87AA001<\/td><\/tr>\n<tr><td>150<\/td><td>0.129<\/td><td>22.5<\/td><td>151<\/td><td>BZHE88AA001<\/td><\/tr>\n<tr><td>185<\/td><td>0.106<\/td><td>24.8<\/td><td>182<\/td><td>BZHE89AA001<\/td><\/tr>\n<tr><td>240<\/td><td>0.0801<\/td><td>27.9<\/td><td>236<\/td><td>BZHE90AA001<\/td><\/tr>\n<tr><td>300<\/td><td>0.0641<\/td><td>30.8<\/td><td>295<\/td><td>BZHE91AA001<\/td><\/tr>\n<tr><td>400<\/td><td>0.0486<\/td><td>34.7<\/td><td>382<\/td><td>BZHE92AA001<\/td><\/tr>\n<tr><td>500<\/td><td>0.0384<\/td><td>40.0<\/td><td>483<\/td><td>BZHE93AA001<\/td><\/tr>\n<tr><td>630<\/td><td>0.0287<\/td><td>44.6<\/td><td>635<\/td><td>BZHE94AA001<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<!-- S8 TUNNEL PROJECTS -->\n<h2>8. Australian Tunnel Projects: Where LSZH Is Now Mandatory<br><small style=\"font-weight:400;font-size:13px;color:var(--cn-c)\">\u6fb3\u5927\u5229\u4e9a\u96a7\u9053\u9879\u76ee\uff1aLSZH \u5df2\u6210\u5f3a\u5236\u8981\u6c42\u7684\u573a\u6240<\/small><\/h2>\n\n<p>The shift is not theoretical \u2014 it is already embedded in the specifications of Australia&#8217;s largest active infrastructure programmes. Standards such as AS\/NZS 3013 for fire and mechanical performance classification and IEC 60332-3 for flame propagation in bunched cables are now standard requirements in tunnel design documentation.<sup>[7][8][2]<\/sup><\/p>\n<div class=\"cn\">\u8fd9\u4e00\u8f6c\u53d8\u5e76\u975e\u7406\u8bba\u6027\u7684\u2014\u2014\u5b83\u5df2\u7ecf\u5d4c\u5165\u6fb3\u5927\u5229\u4e9a\u6700\u5927\u7684\u5728\u5efa\u57fa\u7840\u8bbe\u65bd\u9879\u76ee\u89c4\u8303\u4e2d\u3002AS\/NZS 3013 \u9632\u706b\u548c\u673a\u68b0\u6027\u80fd\u5206\u7c7b\u4ee5\u53ca IEC 60332-3 \u6210\u675f\u7535\u7f06\u706b\u7130\u8513\u5ef6\u7b49\u6807\u51c6\u73b0\u5df2\u6210\u4e3a\u96a7\u9053\u8bbe\u8ba1\u6587\u6863\u7684\u6807\u51c6\u8981\u6c42\u3002<\/div>\n\n<div class=\"tw\">\n<table>\n<caption>Table 7 \u2014 Infrastructure Sectors Requiring LSZH Cable <span style=\"font-weight:400;color:var(--cn-c)\">| \u88687 \u2014 \u8981\u6c42 LSZH \u7535\u7f06\u7684\u57fa\u7840\u8bbe\u65bd\u9886\u57df<\/span><\/caption>\n<thead><tr><th>Sector \u9886\u57df<\/th><th>Application \u5e94\u7528<\/th><th>Regulatory Driver \u6cd5\u89c4\u9a71\u52a8<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Rail Tunnels \u94c1\u8def\u96a7\u9053<\/td><td>Traction power, signalling, comms \u7275\u5f15\u4f9b\u7535\u3001\u4fe1\u53f7\u3001\u901a\u4fe1<\/td><td>AS\/NZS 1670.3, AS\/NZS 3013<\/td><\/tr>\n<tr><td>Road Tunnels \u516c\u8def\u96a7\u9053<\/td><td>Lighting, ventilation, SCADA \u7167\u660e\u3001\u901a\u98ce\u3001SCADA<\/td><td>AS\/NZS 3000, IEC 60332-3<\/td><\/tr>\n<tr><td>Metro Systems \u5730\u94c1\u7cfb\u7edf<\/td><td>Platform power, emergency systems \u7ad9\u53f0\u4f9b\u7535\u3001\u5e94\u6025\u7cfb\u7edf<\/td><td>AS\/NZS 1670.3, AS\/NZS 4507<\/td><\/tr>\n<tr><td>Hospitals \u533b\u9662<\/td><td>Life-safety circuits, operating theatres \u751f\u547d\u5b89\u5168\u56de\u8def\u3001\u624b\u672f\u5ba4<\/td><td>AS\/NZS 3003, AS\/NZS 3013<\/td><\/tr>\n<tr><td>Data Centres \u6570\u636e\u4e2d\u5fc3<\/td><td>Rack power, UPS feeds \u673a\u67b6\u4f9b\u7535\u3001UPS\u9988\u7ebf<\/td><td>IEC 60754, IEC 61034<\/td><\/tr>\n<tr><td>Public Buildings \u516c\u5171\u5efa\u7b51<\/td><td>Fire alarm, emergency lighting \u706b\u707e\u62a5\u8b66\u3001\u5e94\u6025\u7167\u660e<\/td><td>AS\/NZS 1670, AS\/NZS 3013<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<!-- S9 FEICHUN -->\n<h2>9. Feichun LSZH Cable Solutions: Equivalent Performance for Global Projects<br><small style=\"font-weight:400;font-size:13px;color:var(--cn-c)\">\u98de\u7eaf LSZH \u7535\u7f06\u89e3\u51b3\u65b9\u6848\uff1a\u4e3a\u5168\u7403\u9879\u76ee\u63d0\u4f9b\u7b49\u6548\u6027\u80fd<\/small><\/h2>\n\n<p>Anhui Feichun Special Cable Co., Ltd. (\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8) manufactures LSZH power cables engineered to meet the same performance envelope as Olex Envirolex\u00ae, including compliance with IEC 60332-3, IEC 60754, and IEC 61034 fire testing requirements. Our cables utilise halogen-free cross-linked polyolefin insulation with 110 \u00b0C continuous ratings and are available with third-party test certificates from accredited laboratories, supporting specification approval on Australian tunnel and infrastructure projects.<\/p>\n<div class=\"cn\">\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8\u751f\u4ea7\u7684 LSZH \u7535\u529b\u7535\u7f06\u5728\u5de5\u7a0b\u8bbe\u8ba1\u4e0a\u6ee1\u8db3\u4e0e Olex Envirolex\u00ae \u76f8\u540c\u7684\u6027\u80fd\u8981\u6c42\uff0c\u5305\u62ec\u7b26\u5408 IEC 60332-3\u3001IEC 60754 \u548c IEC 61034 \u9632\u706b\u6d4b\u8bd5\u8981\u6c42\u3002\u6211\u4eec\u7684\u7535\u7f06\u4f7f\u7528\u65e0\u5364\u4ea4\u8054\u805a\u70ef\u70c3\u7edd\u7f18\uff0c\u8fde\u7eed\u989d\u5b9a\u6e29\u5ea6 110\u00b0C\uff0c\u5e76\u53ef\u63d0\u4f9b\u8ba4\u53ef\u5b9e\u9a8c\u5ba4\u7684\u7b2c\u4e09\u65b9\u6d4b\u8bd5\u8bc1\u4e66\uff0c\u652f\u6301\u6fb3\u5927\u5229\u4e9a\u96a7\u9053\u548c\u57fa\u7840\u8bbe\u65bd\u9879\u76ee\u7684\u89c4\u8303\u5ba1\u6279\u3002<\/div>\n\n<div class=\"c-info\">\n<b>\u2139 Feichun LSZH Capabilities \u98de\u7eaf LSZH \u80fd\u529b<\/b>\nFeichun&#8217;s LSZH cable range covers single-core and multicore constructions from 1.5 mm\u00b2 to 630 mm\u00b2 at 0.6\/1 kV, with IEC 60332-3 Category A flame propagation compliance, IEC 60754-1\/-2 halogen gas testing, and IEC 61034-2 smoke density verification. All products are manufactured to controlled OD tolerances for compatibility with standard Australian cable management systems. Contact our engineering team for project-specific datasheets and test certificates.<br>\n<span style=\"font-size:13px;\">\u98de\u7eaf\u7684 LSZH \u7535\u7f06\u7cfb\u5217\u6db5\u76d6 1.5mm\u00b2 \u81f3 630mm\u00b2 \u7684\u5355\u82af\u548c\u591a\u82af\u7ed3\u6784\uff0c\u989d\u5b9a\u7535\u538b 0.6\/1kV\uff0c\u7b26\u5408 IEC 60332-3 A \u7c7b\u706b\u7130\u8513\u5ef6\u5408\u89c4\u3001IEC 60754-1\/-2 \u5364\u7d20\u6c14\u4f53\u6d4b\u8bd5\u548c IEC 61034-2 \u70df\u96fe\u5bc6\u5ea6\u9a8c\u8bc1\u3002\u6240\u6709\u4ea7\u54c1\u5916\u5f84\u516c\u5dee\u53d7\u63a7\uff0c\u4e0e\u6807\u51c6\u6fb3\u5927\u5229\u4e9a\u7535\u7f06\u7ba1\u7406\u7cfb\u7edf\u517c\u5bb9\u3002\u8bf7\u8054\u7cfb\u6211\u4eec\u7684\u5de5\u7a0b\u56e2\u961f\u83b7\u53d6\u9879\u76ee\u4e13\u5c5e\u6570\u636e\u8868\u548c\u6d4b\u8bd5\u8bc1\u4e66\u3002<\/span>\n<\/div>\n\n<!-- S10 CONCLUSIONS -->\n<h2>10. Conclusions<br><small style=\"font-weight:400;font-size:13px;color:var(--cn-c)\">\u7ed3\u8bba<\/small><\/h2>\n\n<p>The Australian tunnel infrastructure sector has definitively moved from PVC-based cables like Olex Versolex\u00ae to LSZH alternatives like Olex Envirolex\u00ae. This transition is driven by a clear technical case \u2014 reduced smoke generation, elimination of toxic and corrosive halogen gas emissions, superior flame propagation resistance, and a higher 110 \u00b0C continuous thermal rating \u2014 reinforced by mandatory regulatory requirements under AS\/NZS 3013, AS\/NZS 1670.3, and the IEC 60332\/60754\/61034 test framework. For international cable manufacturers and suppliers, the ability to produce LSZH cables that meet this performance and testing matrix is now a prerequisite for participating in Australian infrastructure projects.<\/p>\n<div class=\"cn\">\u6fb3\u5927\u5229\u4e9a\u96a7\u9053\u57fa\u7840\u8bbe\u65bd\u9886\u57df\u5df2\u660e\u786e\u4ece Olex Versolex\u00ae \u7b49 PVC \u57fa\u7535\u7f06\u8f6c\u5411 Olex Envirolex\u00ae \u7b49 LSZH \u66ff\u4ee3\u54c1\u3002\u8fd9\u4e00\u8f6c\u53d8\u7531\u6e05\u6670\u7684\u6280\u672f\u8bba\u636e\u9a71\u52a8\u2014\u2014\u51cf\u5c11\u70df\u96fe\u4ea7\u751f\u3001\u6d88\u9664\u6709\u6bd2\u8150\u8680\u6027\u5364\u7d20\u6c14\u4f53\u6392\u653e\u3001\u66f4\u4f18\u7684\u706b\u7130\u8513\u5ef6\u963b\u529b\u548c\u66f4\u9ad8\u7684 110\u00b0C \u8fde\u7eed\u70ed\u989d\u5b9a\u503c\u2014\u2014\u5e76\u7531 AS\/NZS 3013\u3001AS\/NZS 1670.3 \u548c IEC 60332\/60754\/61034 \u6d4b\u8bd5\u6846\u67b6\u4e0b\u7684\u5f3a\u5236\u6027\u6cd5\u89c4\u8981\u6c42\u52a0\u4ee5\u5f3a\u5316\u3002\u5bf9\u4e8e\u56fd\u9645\u7535\u7f06\u5236\u9020\u5546\u548c\u4f9b\u5e94\u5546\u800c\u8a00\uff0c\u80fd\u591f\u751f\u4ea7\u6ee1\u8db3\u8fd9\u4e00\u6027\u80fd\u548c\u6d4b\u8bd5\u77e9\u9635\u7684 LSZH \u7535\u7f06\uff0c\u73b0\u5df2\u6210\u4e3a\u53c2\u4e0e\u6fb3\u5927\u5229\u4e9a\u57fa\u7840\u8bbe\u65bd\u9879\u76ee\u7684\u5148\u51b3\u6761\u4ef6\u3002<\/div>\n\n<!-- REFERENCES -->\n<h2>References &amp; Sources<br><small style=\"font-weight:400;font-size:13px;color:var(--cn-c)\">\u53c2\u8003\u6587\u732e\u4e0e\u6765\u6e90<\/small><\/h2>\n<ol class=\"refs\">\n<li>Infrastructure Magazine \u2014 &#8220;Selecting the right cables for tunnels and overhead transport systems&#8221; (2023). <a href=\"https:\/\/infrastructuremagazine.com.au\/2023\/03\/30\/selecting-the-right-cables-for-tunnels-and-overhead-transport-systems\/\" target=\"_blank\" rel=\"nofollow noopener noreferrer\">infrastructuremagazine.com.au<\/a><\/li>\n<li>TST Cables \u2014 &#8220;Requirements and standards for LSZH cables in various countries around the world.&#8221; <a href=\"https:\/\/www.tstcables.com\/do-you-know-the-requirements-and-standards-for-lszh-cables-in-various-countries-around-the-world\/\" target=\"_blank\" rel=\"nofollow noopener noreferrer\">tstcables.com<\/a><\/li>\n<li>Nexans Australia \u2014 Olex Versolex\u00ae Flexible Single Core 90 \u00b0C Product Page. <a href=\"https:\/\/www.nexans.com.au\/en\/products\/Olex-Flex\/VERSOLEX\/VERSOLEX%C2%AE-24480\/product~ID540308051~.html\" target=\"_blank\" rel=\"nofollow noopener noreferrer\">nexans.com.au (Versolex)<\/a><\/li>\n<li>Nexans Australia \u2014 Olex Envirolex\u00ae Flexible Single Core 110 \u00b0C Product Page. <a href=\"https:\/\/www.nexans.com.au\/en\/products\/Olex-Flex\/ENVIROLEX\/ENVIROLEX%C2%AE25073\/product~ID540307880~.html\" target=\"_blank\" rel=\"nofollow noopener noreferrer\">nexans.com.au (Envirolex Single Core)<\/a><\/li>\n<li>Nexans Australia \u2014 Envirolex\u00ae Flexible Multicore Low Fire Hazard Cable. <a href=\"https:\/\/www.nexans.com.au\/en\/products\/Olex-Flex\/ENVIROLEX\/ENVIROLEX%C2%AE25073\/product~BZHE93AA001CXNA~.html\" target=\"_blank\" rel=\"nofollow noopener noreferrer\">nexans.com.au (Envirolex Multicore)<\/a><\/li>\n<li>Nexans Australia \u2014 Envirolex\u00ae 2C+E 4mm\u00b2 Specifications and Datasheet. <a href=\"https:\/\/www.nexans.com.au\/en\/products\/Halogen-Free-and-Fire-Performance\/Low-Fire-Hazard\/ENVIROLEX%C2%AE31504\/product~PTHR06AA002CXHF~.html\" target=\"_blank\" rel=\"nofollow noopener noreferrer\">nexans.com.au (Envirolex 2C+E)<\/a><\/li>\n<li>Standards Australia \u2014 AS\/NZS 3013:2005 Fire and mechanical performance of wiring systems. <a href=\"https:\/\/store.standards.org.au\/product\/as-nzs-3013-2005\" target=\"_blank\" rel=\"nofollow noopener noreferrer\">store.standards.org.au<\/a><\/li>\n<li>NAN Cable \u2014 &#8220;Electrical Cable Types in Australia: TPS &amp; XLPE (AS\/NZS 5000 Guide).&#8221; <a href=\"https:\/\/gdnancable.com\/australia-electrical-cable-types\/\" target=\"_blank\" rel=\"nofollow noopener noreferrer\">gdnancable.com<\/a><\/li>\n<li>IET \u2014 &#8220;Cables and fire protection FAQs&#8221; \u2014 LSF vs. LSZH distinction, BS EN 61034, BS EN 60754 compliance. <a href=\"https:\/\/electrical.theiet.org\/bs-7671\/faqs\/cables-and-fire-protection-faqs\/\" target=\"_blank\" rel=\"nofollow noopener noreferrer\">electrical.theiet.org<\/a><\/li>\n<li>JJ-LAPP \u2014 &#8220;LSZH Cables Boost Fire Safety in Building Infrastructure.&#8221; <a href=\"https:\/\/jj-lapp.com\/blog\/lszh-cables-building-infrastructure-safety\/\" target=\"_blank\" rel=\"nofollow noopener noreferrer\">jj-lapp.com<\/a><\/li>\n<li>Gudacable \u2014 &#8220;LSZH Cable Defined: Meaning, Safety Standards &amp; PVC Comparison.&#8221; <a href=\"https:\/\/www.gudacable.com\/what-is-lszh-cable\/\" target=\"_blank\" rel=\"nofollow noopener noreferrer\">gudacable.com<\/a><\/li>\n<li>Blackwoods (Wesfarmers) \u2014 Nexans Olex Envirolex\u00ae 120mm\u00b2 Product Listing. <a href=\"https:\/\/www.blackwoods.com.au\/electrical\/cables\/building-cables\/nexans-olex-cable-power-low-voltage-single-core-1-x-120mm2-envirolex-flexible-0-6-1kv-black-per-metre\/p\/01130011\" target=\"_blank\" rel=\"nofollow noopener noreferrer\">blackwoods.com.au<\/a><\/li>\n<li>Greenbuildsupply \u2014 &#8220;Elevating Safety: Understanding LSZH Conduits&#8221; \u2014 IEC 60754-1, IEC 61034, NFPA 130. <a href=\"https:\/\/greenbuildsupply.com.au\/news\/safeguarding-australias-power-the-unsung-hero-of-underground-cable-protection-lszh-2\/\" target=\"_blank\" rel=\"nofollow noopener noreferrer\">greenbuildsupply.com.au<\/a><\/li>\n<li>Gudacable \u2014 &#8220;Complete Guide to IEC Standards for Electrical Cables.&#8221; <a href=\"https:\/\/www.gudacable.com\/iec-standards-cables-explained\/\" target=\"_blank\" rel=\"nofollow noopener noreferrer\">gudacable.com (IEC guide)<\/a><\/li>\n<li>Nexans Australia \u2014 Olex-Flex Flexible LSZH Earth Cable \u2014 RHE-3 to AS\/NZS 4507. <a href=\"https:\/\/www.nexans.com.au\/en\/products\/Olex-Flex\/Flexible-Earths\/Olex-Flexs32563.html\" target=\"_blank\" rel=\"nofollow noopener noreferrer\">nexans.com.au (LSZH Earth)<\/a><\/li>\n<\/ol>\n\n<!-- CONTACT -->\n<div class=\"ccard\">\n<h3>Contact Anhui Feichun Special Cable Co., Ltd. \u8054\u7cfb\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/h3>\n<div class=\"cgrid\">\n<div class=\"ci\">\n<span>Technical Support \u6280\u672f\u652f\u6301<\/span>\n<a href=\"mailto:tech@feichuncables.com\" rel=\"nofollow noopener noreferrer\">tech@feichuncables.com<\/a>\n<\/div>\n<div class=\"ci\">\n<span>Sales \u2014 Zihao Yang \u6768\u5b50\u8c6a<\/span>\n<a href=\"mailto:zihao.yang@feichuncables.com\" rel=\"nofollow noopener noreferrer\">zihao.yang@feichuncables.com<\/a>\n<\/div>\n<div class=\"ci\">\n<span>Sales \u2014 Ziyu Huang \u9ec4\u5b50\u94b0<\/span>\n<a href=\"mailto:ziyu.huang@feichuncables.com\" rel=\"nofollow noopener noreferrer\">ziyu.huang@feichuncables.com<\/a>\n<\/div>\n<div class=\"ci\">\n<span>WhatsApp<\/span>\n<a href=\"https:\/\/wa.me\/8613855123218\" target=\"_blank\" rel=\"nofollow noopener noreferrer\" class=\"wab\">\ud83d\udcac +86 138-5512-3218<\/a>\n<\/div>\n<\/div>\n<\/div>\n\n<\/div>\n<\/article>\n\n<!-- ===================== FOOTER ===================== -->\n<footer>\n<div class=\"wrap\">\n<p>&copy; 2025 Anhui Feichun Special Cable Co., Ltd. \u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8 &nbsp;|&nbsp; <a href=\"https:\/\/wa.me\/8613855123218\" target=\"_blank\" rel=\"nofollow noopener noreferrer\">WhatsApp<\/a> &nbsp;|&nbsp; <a href=\"mailto:tech@feichuncables.com\" rel=\"nofollow noopener noreferrer\">tech@feichuncables.com<\/a><\/p>\n<p style=\"margin-top:5px;font-size:11.5px;\">Disclaimer: This article is for technical reference purposes only. Cable selection must be verified against project-specific requirements and the latest edition of all applicable standards. Consult a licensed electrical engineer before making installation decisions.<br>\u514d\u8d23\u58f0\u660e\uff1a\u672c\u6587\u4ec5\u4f9b\u6280\u672f\u53c2\u8003\u3002\u7535\u7f06\u9009\u578b\u987b\u6839\u636e\u9879\u76ee\u7279\u5b9a\u8981\u6c42\u548c\u6240\u6709\u9002\u7528\u6807\u51c6\u7684\u6700\u65b0\u7248\u672c\u8fdb\u884c\u9a8c\u8bc1\u3002\u5b89\u88c5\u51b3\u7b56\u524d\u8bf7\u54a8\u8be2\u6301\u8bc1\u7535\u6c14\u5de5\u7a0b\u5e08\u3002<\/p>\n<\/div>\n<\/footer>\n\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"ustralia&#8217;s expanding infrastructure pipeline \u2014 including the Sydney Metro, Melbourne Metro Tunnel, WestConnex, and Cross River Rail \u2014 has placed fire safety at the centre of cable specification decisions. In enclosed environments such as tunnels, the combustion of conventional PVC-insulated cables releases dense smoke and toxic hydrogen chloride (HCl) gas, severely impeding evacuation and corroding surrounding equipment","protected":false},"author":1,"featured_media":6628,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[66,97],"tags":[20949,10012,10052],"class_list":["post-6627","post","type-post","status-publish","format-standard","has-post-thumbnail","category-common-problems-encountered-in-cable-applications","category-lszh-low-smoke-zero-halogen-flexible-cable","tag-n3ghsshch-lszh","tag-0-6-1kv-lszh-cable","tag-10mm2-lszh","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/6627","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=6627"}],"version-history":[{"count":2,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/6627\/revisions"}],"predecessor-version":[{"id":6630,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/6627\/revisions\/6630"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/6628"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=6627"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=6627"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=6627"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}