{"id":6587,"date":"2026-02-09T11:55:01","date_gmt":"2026-02-09T03:55:01","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=6587"},"modified":"2026-02-09T11:55:05","modified_gmt":"2026-02-09T03:55:05","slug":"rheyfirm-rs-vs-rheyfirm-rts-when-to-choose-rheyfirm-ke-kevlar-ntskcgecwou-for-ultra-long-vertical-travel","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/rheyfirm-rs-vs-rheyfirm-rts-when-to-choose-rheyfirm-ke-kevlar-ntskcgecwou-for-ultra-long-vertical-travel\/","title":{"rendered":"RHEYFIRM\u00ae (RS) vs. RHEYFIRM\u00ae (RTS): When to Choose RHEYFIRM\u00ae KE Kevlar (N)TSKCGECW\u00d6U for Ultra-Long Vertical Travel"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">RHEYFIRM\u00ae (RS) \u4e0e RHEYFIRM\u00ae (RTS) \u5bf9\u6bd4\uff1a\u4f55\u65f6\u9009\u62e9 RHEYFIRM\u00ae KE \u51ef\u592b\u62c9 (N)TSKCGECW\u00d6U \u8d85\u957f\u5782\u76f4\u884c\u7a0b\u7535\u7f06<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"7d878b\" data-has-transparency=\"false\" style=\"--dominant-color: #7d878b;\" loading=\"lazy\" decoding=\"async\" width=\"1104\" height=\"533\" sizes=\"auto, (max-width: 1104px) 100vw, 1104px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-768.avif\" alt=\"\" class=\"wp-image-6588 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-768.avif 1104w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-768-300x145.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-768-768x371.avif 768w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-768-400x193.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-768-800x386.avif 800w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-768-832x402.avif 832w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n<title>RHEYFIRM\u00ae (RS) vs. RHEYFIRM\u00ae (RTS): When to Choose RHEYFIRM\u00ae KE Kevlar (N)TSKCGECW\u00d6U for Ultra-Long Vertical Travel | Anhui Feichun Special Cable<\/title>\n<meta name=\"description\" content=\"Technical comparison of RHEYFIRM\u00ae KE Kevlar-reinforced cables (N)TSKCGECW\u00d6U vs Nexans cables for ultra-long vertical travel applications in mining, cranes, and elevators.\">\n<style>\n:root {\n  --bg-primary: #ffffff;\n  --bg-secondary: #f8f9fa;\n  --bg-table: #ffffff;\n  --text-primary: #1a1a2e;\n  --text-secondary: #4a4a68;\n  --text-muted: #6c757d;\n  --border-color: #dee2e6;\n  --accent-color: #0056b3;\n  --accent-hover: #003d82;\n  --highlight-bg: #e8f4fd;\n  --success-color: #198754;\n  --warning-color: #fd7e14;\n  --table-header-bg: #2c3e50;\n  --table-header-text: #ffffff;\n  --table-row-alt: #f8f9fa;\n  --shadow-sm: 0 1px 3px rgba(0,0,0,0.08);\n  --shadow-md: 0 4px 12px rgba(0,0,0,0.1);\n  --chinese-text: #5a6268;\n}\n@media (prefers-color-scheme: dark) {\n  :root {\n    --bg-primary: #1a1a2e;\n    --bg-secondary: #16213e;\n    --bg-table: #1e2a3a;\n    --text-primary: #e8e8e8;\n    --text-secondary: #b8b8c8;\n    --text-muted: #8a8a9a;\n    --border-color: #3a3a5a;\n    --accent-color: #4dabf7;\n    --accent-hover: #74c0fc;\n    --highlight-bg: #1e3a5f;\n    --success-color: #51cf66;\n    --warning-color: #ffa94d;\n    --table-header-bg: #0f3460;\n    --table-header-text: #ffffff;\n    --table-row-alt: #232940;\n    --shadow-sm: 0 1px 3px rgba(0,0,0,0.3);\n    --shadow-md: 0 4px 12px rgba(0,0,0,0.4);\n    --chinese-text: #9ca3af;\n  }\n}\n* { margin: 0; padding: 0; box-sizing: border-box; }\nbody {\n  font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, \"Helvetica Neue\", Arial, sans-serif;\n  background-color: var(--bg-primary);\n  color: var(--text-primary);\n  line-height: 1.7;\n  font-size: 16px;\n}\n.container {\n  max-width: 1100px;\n  margin: 0 auto;\n  padding: 40px 24px;\n}\nheader {\n  border-bottom: 3px solid var(--accent-color);\n  padding-bottom: 24px;\n  margin-bottom: 32px;\n}\n.company-name {\n  font-size: 14px;\n  color: var(--accent-color);\n  font-weight: 600;\n  letter-spacing: 0.5px;\n  margin-bottom: 8px;\n}\nh1 {\n  font-size: clamp(1.5rem, 4vw, 2.2rem);\n  font-weight: 700;\n  color: var(--text-primary);\n  margin-bottom: 12px;\n  line-height: 1.3;\n}\n.subtitle-cn {\n  font-size: 15px;\n  color: var(--chinese-text);\n  font-style: italic;\n  margin-bottom: 16px;\n}\n.meta-info {\n  font-size: 13px;\n  color: var(--text-muted);\n}\nh2 {\n  font-size: 1.4rem;\n  color: var(--text-primary);\n  margin: 36px 0 16px;\n  padding-bottom: 8px;\n  border-bottom: 2px solid var(--border-color);\n}\nh3 {\n  font-size: 1.15rem;\n  color: var(--text-primary);\n  margin: 28px 0 12px;\n}\np { margin-bottom: 16px; color: var(--text-secondary); }\n.cn-note {\n  font-size: 14px;\n  color: var(--chinese-text);\n  background: var(--bg-secondary);\n  padding: 12px 16px;\n  border-left: 3px solid var(--accent-color);\n  margin: 16px 0;\n}\n.table-wrapper {\n  overflow-x: auto;\n  margin: 24px 0;\n  border-radius: 8px;\n  box-shadow: var(--shadow-md);\n}\ntable {\n  width: 100%;\n  border-collapse: collapse;\n  font-size: 14px;\n  background: var(--bg-table);\n}\nthead th {\n  background: var(--table-header-bg);\n  color: var(--table-header-text);\n  padding: 14px 12px;\n  text-align: left;\n  font-weight: 600;\n  font-size: 13px;\n  text-transform: uppercase;\n  letter-spacing: 0.3px;\n}\ntbody td {\n  padding: 12px;\n  border-bottom: 1px solid var(--border-color);\n  vertical-align: top;\n}\ntbody tr:nth-child(even) { background: var(--table-row-alt); }\ntbody tr:hover { background: var(--highlight-bg); }\n.param-name {\n  font-weight: 600;\n  color: var(--text-primary);\n  min-width: 140px;\n}\n.param-cn {\n  font-size: 12px;\n  color: var(--chinese-text);\n  display: block;\n  margin-top: 2px;\n}\n.highlight-cell {\n  background: var(--highlight-bg);\n  font-weight: 600;\n  color: var(--success-color);\n}\n.specs-box {\n  background: var(--bg-secondary);\n  border: 1px solid var(--border-color);\n  border-radius: 8px;\n  padding: 20px;\n  margin: 20px 0;\n}\n.specs-box h4 {\n  font-size: 15px;\n  color: var(--accent-color);\n  margin-bottom: 12px;\n}\n.specs-list {\n  font-size: 14px;\n  color: var(--text-secondary);\n}\n.specs-list span {\n  display: inline-block;\n  margin-right: 20px;\n  margin-bottom: 6px;\n}\n.source-ref {\n  font-size: 12px;\n  color: var(--text-muted);\n  margin-top: 8px;\n}\n.source-ref a {\n  color: var(--accent-color);\n  text-decoration: none;\n}\n.source-ref a:hover { text-decoration: underline; }\n.application-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(280px, 1fr));\n  gap: 20px;\n  margin: 24px 0;\n}\n.app-card {\n  background: var(--bg-secondary);\n  border: 1px solid var(--border-color);\n  border-radius: 8px;\n  padding: 20px;\n}\n.app-card h4 {\n  font-size: 15px;\n  color: var(--text-primary);\n  margin-bottom: 8px;\n}\n.app-card p {\n  font-size: 14px;\n  margin-bottom: 8px;\n}\n.decision-table td:first-child { font-weight: 600; }\n.contact-section {\n  background: var(--bg-secondary);\n  border: 1px solid var(--border-color);\n  border-radius: 8px;\n  padding: 28px;\n  margin-top: 40px;\n}\n.contact-section h3 {\n  margin-top: 0;\n  color: var(--accent-color);\n}\n.contact-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(240px, 1fr));\n  gap: 16px;\n  margin-top: 16px;\n}\n.contact-item {\n  font-size: 14px;\n  color: var(--text-secondary);\n}\n.contact-item strong {\n  display: block;\n  color: var(--text-primary);\n  margin-bottom: 4px;\n}\n.contact-item a {\n  color: var(--accent-color);\n  text-decoration: none;\n}\n.contact-item a:hover { text-decoration: underline; }\n.references {\n  margin-top: 40px;\n  padding-top: 24px;\n  border-top: 1px solid var(--border-color);\n}\n.references h3 { margin-top: 0; }\n.ref-list {\n  font-size: 13px;\n  color: var(--text-muted);\n}\n.ref-list li { margin-bottom: 8px; }\n.ref-list a {\n  color: var(--accent-color);\n  text-decoration: none;\n  word-break: break-word;\n}\nfooter {\n  margin-top: 48px;\n  padding-top: 24px;\n  border-top: 1px solid var(--border-color);\n  font-size: 13px;\n  color: var(--text-muted);\n  text-align: center;\n}\n<\/style>\n<\/head>\n<body>\n<div class=\"container\">\n<header>\n<div class=\"company-name\">ANHUI FEICHUN SPECIAL CABLE CO., LTD. \u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/div>\n<h1>RHEYFIRM\u00ae (RS) vs. RHEYFIRM\u00ae (RTS): When to Choose RHEYFIRM\u00ae KE Kevlar (N)TSKCGECW\u00d6U for Ultra-Long Vertical Travel<\/h1>\n<p class=\"subtitle-cn\">RHEYFIRM\u00ae (RS) \u4e0e RHEYFIRM\u00ae (RTS) \u5bf9\u6bd4\uff1a\u4f55\u65f6\u9009\u62e9 RHEYFIRM\u00ae KE \u51ef\u592b\u62c9 (N)TSKCGECW\u00d6U \u8d85\u957f\u5782\u76f4\u884c\u7a0b\u7535\u7f06<\/p>\n<p class=\"meta-info\">Technical Engineering Guide | DIN VDE 0250-813 Compliant Cables | Mining &#038; Material Handling Applications<\/p>\n<\/header>\n\n<section>\n<h2>1. Introduction to RHEYFIRM\u00ae Cable Series \u6982\u8ff0<\/h2>\n<p>The RHEYFIRM\u00ae cable series represents the industry benchmark for flexible reeling and trailing cables designed for extreme mechanical stress applications. These cables are engineered to DIN VDE 0250-813 standards, which remain the globally recognized specification for tough rubber-sheathed flexible reeling cables used in cranes, mining equipment, and material handling machinery.<\/p>\n<div class=\"cn-note\">\n<strong>\u4e2d\u6587\u8bf4\u660e\uff1a<\/strong>RHEYFIRM\u00ae \u7535\u7f06\u7cfb\u5217\u662f\u4e13\u4e3a\u6781\u7aef\u673a\u68b0\u5e94\u529b\u5e94\u7528\u8bbe\u8ba1\u7684\u67d4\u6027\u5377\u7b52\u548c\u62d6\u66f3\u7535\u7f06\u7684\u884c\u4e1a\u6807\u6746\u3002\u8fd9\u4e9b\u7535\u7f06\u6309\u7167 DIN VDE 0250-813 \u6807\u51c6\u8bbe\u8ba1\uff0c\u8be5\u6807\u51c6\u662f\u5168\u7403\u516c\u8ba4\u7684\u8d77\u91cd\u673a\u3001\u91c7\u77ff\u8bbe\u5907\u548c\u7269\u6599\u642c\u8fd0\u673a\u68b0\u7528\u8010\u78e8\u6a61\u80f6\u62a4\u5957\u67d4\u6027\u5377\u7f06\u89c4\u8303\u3002\n<\/div>\n<p>When vertical travel distances exceed conventional limits, particularly in deep shaft mining, high-rise elevator systems, and ship-to-shore crane applications, the selection between standard steel-reinforced cables and Kevlar (aramid fiber) reinforced alternatives becomes critical for operational safety and longevity.<\/p>\n<p class=\"source-ref\">Reference: <a href=\"https:\/\/www.elandcables.com\/electrical-cable-and-accessories\/cables-by-standard\/vde0250-cable\" rel=\"nofollow noopener\" target=\"_blank\">Eland Cables &#8211; DIN VDE 0250 Standard<\/a><\/p>\n<\/section>\n\n<section>\n<h2>2. Cable Designation Nomenclature \u7535\u7f06\u578b\u53f7\u547d\u540d\u89c4\u5219<\/h2>\n<p>Understanding the designation codes is essential for proper cable selection. The nomenclature follows DIN VDE conventions where each letter indicates specific construction features:<\/p>\n<div class=\"table-wrapper\">\n<table>\n<thead>\n<tr><th>Code \u4ee3\u7801<\/th><th>Meaning \u542b\u4e49<\/th><th>Technical Significance \u6280\u672f\u610f\u4e49<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td class=\"param-name\">N<span class=\"param-cn\">N<\/span><\/td><td>Standardized cable \u6807\u51c6\u5316\u7535\u7f06<\/td><td>Manufactured to recognized national standards<\/td><\/tr>\n<tr><td class=\"param-name\">T<span class=\"param-cn\">T<\/span><\/td><td>Trailing\/Reeling cable \u62d6\u66f3\/\u5377\u7b52\u7535\u7f06<\/td><td>Designed for continuous flexing applications<\/td><\/tr>\n<tr><td class=\"param-name\">S<span class=\"param-cn\">S<\/span><\/td><td>Reinforced sheath \u52a0\u5f3a\u62a4\u5957<\/td><td>Enhanced mechanical protection<\/td><\/tr>\n<tr><td class=\"param-name\">K<span class=\"param-cn\">K<\/span><\/td><td>Kevlar\/Aramid reinforcement \u51ef\u592b\u62c9\/\u82b3\u7eb6\u52a0\u5f3a<\/td><td>Lightweight high-tensile strength member<\/td><\/tr>\n<tr><td class=\"param-name\">C<span class=\"param-cn\">C<\/span><\/td><td>Metallic conductive layer \u91d1\u5c5e\u5bfc\u7535\u5c42<\/td><td>EMC shielding capability<\/td><\/tr>\n<tr><td class=\"param-name\">CGE<span class=\"param-cn\">CGE<\/span><\/td><td>Non-metallic conductive layer on insulation \u7edd\u7f18\u4e0a\u7684\u975e\u91d1\u5c5e\u5bfc\u7535\u5c42<\/td><td>Electrical field control<\/td><\/tr>\n<tr><td class=\"param-name\">W<span class=\"param-cn\">W<\/span><\/td><td>Control\/monitoring wires \u63a7\u5236\/\u76d1\u63a7\u7ebf\u82af<\/td><td>Integrated auxiliary circuits<\/td><\/tr>\n<tr><td class=\"param-name\">\u00d6<span class=\"param-cn\">\u00d6<\/span><\/td><td>Oil resistant \u8010\u6cb9<\/td><td>Suitable for industrial environments<\/td><\/tr>\n<tr><td class=\"param-name\">U<span class=\"param-cn\">U<\/span><\/td><td>Flame retardant \u963b\u71c3<\/td><td>Fire safety compliance<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"source-ref\">Reference: <a href=\"https:\/\/feichuncables.com\/blog\/din-vde-0250\/\" rel=\"nofollow noopener\" target=\"_blank\">Feichun Cables &#8211; DIN VDE 0250 Technical Guide<\/a><\/p>\n<\/section>\n\n<section>\n<h2>3. RHEYFIRM\u00ae (RS) vs. RHEYFIRM\u00ae (RTS): Core Differences \u6838\u5fc3\u5dee\u5f02<\/h2>\n<p>The distinction between RS and RTS designations relates to the intended operating conditions and mechanical stress profiles:<\/p>\n<div class=\"table-wrapper\">\n<table>\n<thead>\n<tr><th>Parameter \u53c2\u6570<\/th><th>RHEYFIRM\u00ae (RS) (N)TSCGEWTOEUS<\/th><th>RHEYFIRM\u00ae (RTS) (N)TSCGEWTOEUS<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td class=\"param-name\">Primary Application<span class=\"param-cn\">\u4e3b\u8981\u5e94\u7528<\/span><\/td><td>Ship-to-shore connections, moderate reeling\u901f\u5ea6<\/td><td>High-speed reeling, extreme torsional stress \u9ad8\u901f\u5377\u7ed5\u3001\u6781\u7aef\u626d\u8f6c\u5e94\u529b<\/td><\/tr>\n<tr><td class=\"param-name\">Reeling Speed<span class=\"param-cn\">\u5377\u7ed5\u901f\u5ea6<\/span><\/td><td>Up to 120 m\/min<\/td><td class=\"highlight-cell\">Up to 190 m\/min<\/td><\/tr>\n<tr><td class=\"param-name\">Torsional Stress<span class=\"param-cn\">\u626d\u8f6c\u5e94\u529b<\/span><\/td><td>Standard \u6807\u51c6<\/td><td class=\"highlight-cell\">Enhanced \u589e\u5f3a<\/td><\/tr>\n<tr><td class=\"param-name\">Deflection Planes<span class=\"param-cn\">\u504f\u8f6c\u5e73\u9762<\/span><\/td><td>Single plane preferred \u5355\u5e73\u9762\u4f18\u5148<\/td><td>Multi-plane capable \u591a\u5e73\u9762\u9002\u7528<\/td><\/tr>\n<tr><td class=\"param-name\">Voltage Rating<span class=\"param-cn\">\u989d\u5b9a\u7535\u538b<\/span><\/td><td>6\/10 kV to 18\/30 kV<\/td><td>6\/10 kV to 18\/30 kV<\/td><\/tr>\n<tr><td class=\"param-name\">Core Design<span class=\"param-cn\">\u7ebf\u82af\u8bbe\u8ba1<\/span><\/td><td>3 phase + 2 earth conductors<\/td><td>6-core (3 phase + 3 PE in interstices)<\/td><\/tr>\n<tr><td class=\"param-name\">Typical Equipment<span class=\"param-cn\">\u5178\u578b\u8bbe\u5907<\/span><\/td><td>Container vessels, ferries \u96c6\u88c5\u7bb1\u8239\u3001\u6e21\u8f6e<\/td><td>STS cranes, RMG cranes, stackers STS\u8d77\u91cd\u673a\u3001RMG\u8d77\u91cd\u673a\u3001\u5806\u53d6\u6599\u673a<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"cn-note\">\n<strong>\u4e2d\u6587\u8bf4\u660e\uff1a<\/strong>RS \u7cfb\u5217\u8bbe\u8ba1\u7528\u4e8e\u8239\u5bf9\u5cb8\u8fde\u63a5\u548c\u4e2d\u7b49\u5377\u7ed5\u901f\u5ea6\u573a\u5408\uff0c\u800c RTS \u7cfb\u5217\u4e13\u4e3a\u9ad8\u901f\u5377\u7ed5\uff08\u6700\u9ad8190\u7c73\/\u5206\u949f\uff09\u548c\u6781\u7aef\u626d\u8f6c\u5e94\u529b\u5de5\u51b5\u4f18\u5316\u3002RTS\u91c7\u7528\u516d\u82af\u8bbe\u8ba1\uff0c\u4e09\u6839\u76f8\u7ebf\u52a0\u4e09\u6839\u4fdd\u62a4\u63a5\u5730\u7ebf\u5206\u5e03\u5728\u95f4\u9699\u4e2d\uff0c\u63d0\u4f9b\u66f4\u4f18\u7684EMC\u6027\u80fd\u3002\n<\/div>\n<p class=\"source-ref\">References: <a href=\"https:\/\/www.cse-distributors.co.uk\/cable\/nexans-handling-cable\/rheyfirmrts-ntscgewtoeus-cable.html\" rel=\"nofollow noopener\" target=\"_blank\">CSE Distributors &#8211; RHEYFIRM RTS<\/a> | <a href=\"https:\/\/www.nexans.de\/eservice\/Germany-en\/navigate_342578\/RHEYFIRM_RTS_R_N_TSCGEWTOEUS_8_7_15_kV.html\" rel=\"nofollow noopener\" target=\"_blank\">Nexans Germany &#8211; RHEYFIRM RTS Specifications<\/a><\/p>\n<\/section>\n\n<section>\n<h2>4. RHEYFIRM\u00ae KE Kevlar (N)TSKCGECW\u00d6U: Ultra-Long Vertical Travel Solution \u8d85\u957f\u5782\u76f4\u884c\u7a0b\u89e3\u51b3\u65b9\u6848<\/h2>\n<p>For applications requiring vertical travel distances exceeding 300 meters, conventional steel-reinforced cables face significant limitations due to self-weight loading. The RHEYFIRM\u00ae KE series incorporates Kevlar (aramid fiber) reinforcement to address these challenges.<\/p>\n\n<h3>4.1 Kevlar Reinforcement Advantages \u51ef\u592b\u62c9\u52a0\u5f3a\u4f18\u52bf<\/h3>\n<div class=\"specs-box\">\n<h4>Kevlar Aramid Fiber Properties \u51ef\u592b\u62c9\u82b3\u7eb6\u7ea4\u7ef4\u7279\u6027<\/h4>\n<div class=\"specs-list\">\n<span><strong>Tensile Strength \u6297\u62c9\u5f3a\u5ea6:<\/strong> \u22483,000 N\/mm\u00b2<\/span>\n<span><strong>Density \u5bc6\u5ea6:<\/strong> \u22481,450 kg\/m\u00b3<\/span>\n<span><strong>Strength-to-Weight Ratio \u5f3a\u91cd\u6bd4:<\/strong> Up to 10\u00d7 steel<\/span>\n<span><strong>Elongation \u5ef6\u4f38\u7387:<\/strong> 0.7% creep over 200 hours<\/span>\n<span><strong>Temperature Resistance \u8010\u6e29:<\/strong> Up to 450\u00b0C<\/span>\n<\/div>\n<\/div>\n<p>According to DuPont technical documentation, Kevlar aramid fiber provides strength comparable to steel while maintaining only 14-15% of the weight. This characteristic makes Kevlar-reinforced cables the optimal choice for ultra-long vertical applications where cable self-weight becomes a limiting factor.<\/p>\n<p class=\"source-ref\">Reference: <a href=\"https:\/\/www.dupont.com\/fabrics-fibers-and-nonwovens\/ropes-cables.html\" rel=\"nofollow noopener\" target=\"_blank\">DuPont &#8211; Kevlar\u00ae Ropes and Cables<\/a><\/p>\n\n<h3>4.2 (N)TSKCGECW\u00d6U Technical Specifications \u6280\u672f\u89c4\u683c<\/h3>\n<div class=\"table-wrapper\">\n<table>\n<thead>\n<tr><th>Specification \u89c4\u683c<\/th><th>Value \u6570\u503c<\/th><th>Standard \u6807\u51c6<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td class=\"param-name\">Voltage Rating<span class=\"param-cn\">\u989d\u5b9a\u7535\u538b<\/span><\/td><td>3.6\/6 kV to 12\/20 kV<\/td><td>DIN VDE 0250-813<\/td><\/tr>\n<tr><td class=\"param-name\">Conductor<span class=\"param-cn\">\u5bfc\u4f53<\/span><\/td><td>Tinned copper, Class 5 flexible<\/td><td>DIN VDE 0295 \/ IEC 60228<\/td><\/tr>\n<tr><td class=\"param-name\">Insulation<span class=\"param-cn\">\u7edd\u7f18<\/span><\/td><td>EPR type 3GI3<\/td><td>DIN VDE 0207-20<\/td><\/tr>\n<tr><td class=\"param-name\">Sheath<span class=\"param-cn\">\u62a4\u5957<\/span><\/td><td>Synthetic thermosetting 5GM5<\/td><td>DIN VDE 0207-21<\/td><\/tr>\n<tr><td class=\"param-name\">Reinforcement<span class=\"param-cn\">\u52a0\u5f3a\u4ef6<\/span><\/td><td>Kevlar aramid fiber core<\/td><td>Proprietary design<\/td><\/tr>\n<tr><td class=\"param-name\">Temperature Range<span class=\"param-cn\">\u6e29\u5ea6\u8303\u56f4<\/span><\/td><td>-25\u00b0C to +90\u00b0C (mobile)<\/td><td>DIN VDE 0298-3<\/td><\/tr>\n<tr><td class=\"param-name\">Min. Bending Radius<span class=\"param-cn\">\u6700\u5c0f\u5f2f\u66f2\u534a\u5f84<\/span><\/td><td>8\u00d7 cable diameter<\/td><td>DIN VDE 0298-3<\/td><\/tr>\n<tr><td class=\"param-name\">Oil Resistance<span class=\"param-cn\">\u8010\u6cb9\u6027<\/span><\/td><td>Yes \u662f<\/td><td>DIN VDE 0472<\/td><\/tr>\n<tr><td class=\"param-name\">Flame Retardant<span class=\"param-cn\">\u963b\u71c3<\/span><\/td><td>IEC 60332-1-2 compliant<\/td><td>EN 60332-1-2<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"cn-note\">\n<strong>\u4e2d\u6587\u8bf4\u660e\uff1a<\/strong>(N)TSKCGECW\u00d6U \u7535\u7f06\u91c7\u7528\u51ef\u592b\u62c9\u82b3\u7eb6\u7ea4\u7ef4\u82af\u52a0\u5f3a\uff0c\u914d\u5408\u9540\u9521\u94dc\u5bfc\u4f53\uff085\u7c7b\u67d4\u6027\uff09\u3001EPR\u7edd\u7f18\uff083GI3\u578b\uff09\u548c\u5408\u6210\u70ed\u56fa\u6027\u62a4\u5957\uff085GM5\u578b\uff09\u3002\u9002\u7528\u4e8e\u91c7\u7164\u673a\u3001\u96a7\u9053\u6398\u8fdb\u673a\u7b49\u9700\u8981\u6781\u9ad8\u673a\u68b0\u5f3a\u5ea6\u7684\u5e94\u7528\u573a\u5408\u3002\n<\/div>\n<p class=\"source-ref\">References: <a href=\"https:\/\/tratosgroup.com\/products\/special-cables\/mining-tunneling-cables\/page\/3\/\" rel=\"nofollow noopener\" target=\"_blank\">Tratos Group &#8211; Mining Cables NTSKCGECW\u00d6U<\/a> | <a href=\"https:\/\/www.powerandcables.com\/wp-content\/uploads\/2017\/07\/Mining-Cables-T-F-Kable-Catalogue.pdf\" rel=\"nofollow noopener\" target=\"_blank\">TF Kable Mining Cable Catalogue<\/a><\/p>\n<\/section>\n\n<section>\n<h2>5. Steel vs. Kevlar Reinforcement: Comparative Analysis \u94a2\u4e1d\u4e0e\u51ef\u592b\u62c9\u52a0\u5f3a\u5bf9\u6bd4\u5206\u6790<\/h2>\n<div class=\"table-wrapper\">\n<table>\n<thead>\n<tr><th>Parameter \u53c2\u6570<\/th><th>Steel Wire Reinforced \u94a2\u4e1d\u52a0\u5f3a<\/th><th>Kevlar Aramid Reinforced \u51ef\u592b\u62c9\u82b3\u7eb6\u52a0\u5f3a<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td class=\"param-name\">Weight Efficiency<span class=\"param-cn\">\u91cd\u91cf\u6548\u7387<\/span><\/td><td>Standard baseline \u6807\u51c6\u57fa\u51c6<\/td><td class=\"highlight-cell\">60-70% weight reduction<\/td><\/tr>\n<tr><td class=\"param-name\">Tensile Modulus<span class=\"param-cn\">\u62c9\u4f38\u6a21\u91cf<\/span><\/td><td>\u2248200,000 N\/mm\u00b2<\/td><td>\u2248100,000 N\/mm\u00b2<\/td><\/tr>\n<tr><td class=\"param-name\">Max. Vertical Travel<span class=\"param-cn\">\u6700\u5927\u5782\u76f4\u884c\u7a0b<\/span><\/td><td>Limited by self-weight<\/td><td class=\"highlight-cell\">Extended capability<\/td><\/tr>\n<tr><td class=\"param-name\">Crush Resistance<span class=\"param-cn\">\u6297\u538b\u6027<\/span><\/td><td class=\"highlight-cell\">Excellent \u4f18\u79c0<\/td><td>Moderate (relies on sheath)<\/td><\/tr>\n<tr><td class=\"param-name\">Corrosion Resistance<span class=\"param-cn\">\u8010\u8150\u8680\u6027<\/span><\/td><td>Requires galvanization<\/td><td class=\"highlight-cell\">Inherently resistant<\/td><\/tr>\n<tr><td class=\"param-name\">Fatigue Performance<span class=\"param-cn\">\u75b2\u52b3\u6027\u80fd<\/span><\/td><td>Good \u826f\u597d<\/td><td class=\"highlight-cell\">Excellent \u4f18\u79c0<\/td><\/tr>\n<tr><td class=\"param-name\">UV Resistance<span class=\"param-cn\">\u6297\u7d2b\u5916\u7ebf<\/span><\/td><td class=\"highlight-cell\">Not affected \u4e0d\u53d7\u5f71\u54cd<\/td><td>Requires protection<\/td><\/tr>\n<tr><td class=\"param-name\">Cost Factor<span class=\"param-cn\">\u6210\u672c\u56e0\u7d20<\/span><\/td><td class=\"highlight-cell\">Lower initial cost<\/td><td>Higher initial, lower lifecycle<\/td><\/tr>\n<tr><td class=\"param-name\">Electrical Properties<span class=\"param-cn\">\u7535\u6c14\u7279\u6027<\/span><\/td><td>Conductive (grounding)<\/td><td>Non-conductive \u975e\u5bfc\u7535<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>The engineering decision between steel and Kevlar reinforcement depends on the specific vertical travel requirements and operating conditions. For deep shaft mining hoists exceeding 500 meters, Kevlar reinforcement provides significant advantages in reducing total suspended cable weight while maintaining required tensile strength.<\/p>\n<p class=\"source-ref\">Reference: <a href=\"https:\/\/blog.deregtcables.com\/news\/steel-vs.-aramid-fibre-what-is-the-best-cable-solution\" rel=\"nofollow noopener\" target=\"_blank\">DeRegt Cables &#8211; Steel vs. Aramid Fibre Comparison<\/a><\/p>\n<\/section>\n\n<section>\n<h2>6. Application Selection Guidelines \u5e94\u7528\u9009\u578b\u6307\u5357<\/h2>\n<div class=\"application-grid\">\n<div class=\"app-card\">\n<h4>Deep Shaft Mining Hoists \u6df1\u4e95\u77ff\u5c71\u63d0\u5347\u673a<\/h4>\n<p><strong>Recommended \u63a8\u8350:<\/strong> RHEYFIRM\u00ae KE (N)TSKCGECW\u00d6U<\/p>\n<p>Vertical travel &gt;300m requires Kevlar reinforcement to manage cable self-weight. The non-conductive nature of aramid fibers provides additional safety in potentially explosive atmospheres.<\/p>\n<\/div>\n<div class=\"app-card\">\n<h4>Ship-to-Shore Cranes (STS) \u5cb8\u6865\u8d77\u91cd\u673a<\/h4>\n<p><strong>Recommended \u63a8\u8350:<\/strong> RHEYFIRM\u00ae (RTS) (N)TSCGEWTOEUS<\/p>\n<p>High reeling speeds up to 190 m\/min with multi-plane deflection capability. Integrated optical fiber options available for data transmission.<\/p>\n<\/div>\n<div class=\"app-card\">\n<h4>Open-Pit Mining Excavators \u9732\u5929\u77ff\u6316\u6398\u673a<\/h4>\n<p><strong>Recommended \u63a8\u8350:<\/strong> RHEYFIRM\u00ae (RTS) R-(N)TSCGEWTOEUS<\/p>\n<p>Level-wind reel applications with high torsional stress. Steel reinforcement provides crush resistance for drum winding.<\/p>\n<\/div>\n<div class=\"app-card\">\n<h4>High-Rise Elevator Systems \u9ad8\u5c42\u7535\u68af\u7cfb\u7edf<\/h4>\n<p><strong>Recommended \u63a8\u8350:<\/strong> Kevlar-core traveling cable<\/p>\n<p>Travel heights &gt;160m benefit from Kevlar reinforcement. Reduced cable weight enables smaller pulleys and lower energy consumption.<\/p>\n<\/div>\n<\/div>\n\n<h3>6.1 Decision Matrix: When to Choose Kevlar \u4f55\u65f6\u9009\u62e9\u51ef\u592b\u62c9\u52a0\u5f3a<\/h3>\n<div class=\"table-wrapper\">\n<table class=\"decision-table\">\n<thead>\n<tr><th>Condition \u6761\u4ef6<\/th><th>Steel Reinforcement \u94a2\u4e1d\u52a0\u5f3a<\/th><th>Kevlar Reinforcement \u51ef\u592b\u62c9\u52a0\u5f3a<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td>Vertical travel &lt;200m \u5782\u76f4\u884c\u7a0b&lt;200\u7c73<\/td><td>\u2713 Preferred \u4f18\u9009<\/td><td>Optional \u53ef\u9009<\/td><\/tr>\n<tr><td>Vertical travel 200-400m<\/td><td>Acceptable \u53ef\u63a5\u53d7<\/td><td>\u2713 Recommended \u63a8\u8350<\/td><\/tr>\n<tr><td>Vertical travel &gt;400m<\/td><td>Not recommended \u4e0d\u63a8\u8350<\/td><td>\u2713 Required \u5fc5\u9700<\/td><\/tr>\n<tr><td>High reeling speed (&gt;150 m\/min)<\/td><td>\u2713 Preferred \u4f18\u9009<\/td><td>Acceptable \u53ef\u63a5\u53d7<\/td><\/tr>\n<tr><td>Corrosive environment \u8150\u8680\u73af\u5883<\/td><td>Requires protection<\/td><td>\u2713 Preferred \u4f18\u9009<\/td><\/tr>\n<tr><td>Crush\/abrasion exposure \u538b\u788e\/\u78e8\u635f<\/td><td>\u2713 Preferred \u4f18\u9009<\/td><td>Requires sheath protection<\/td><\/tr>\n<tr><td>Weight-sensitive systems \u91cd\u91cf\u654f\u611f\u7cfb\u7edf<\/td><td>Limited application<\/td><td>\u2713 Preferred \u4f18\u9009<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"cn-note\">\n<strong>\u4e2d\u6587\u8bf4\u660e\uff1a<\/strong>\u9009\u62e9\u51ef\u592b\u62c9\u52a0\u5f3a\u7535\u7f06\u7684\u5173\u952e\u8003\u8651\u56e0\u7d20\u5305\u62ec\uff1a\u5782\u76f4\u884c\u7a0b\u8d85\u8fc7200\u7c73\u3001\u91cd\u91cf\u654f\u611f\u578b\u7cfb\u7edf\u3001\u8150\u8680\u6027\u73af\u5883\u3002\u5bf9\u4e8e\u9ad8\u5377\u7ed5\u901f\u5ea6\u548c\u6297\u538b\/\u8010\u78e8\u8981\u6c42\u8f83\u9ad8\u7684\u573a\u5408\uff0c\u94a2\u4e1d\u52a0\u5f3a\u4ecd\u662f\u9996\u9009\u3002\n<\/div>\n<\/section>\n\n<section>\n<h2>7. Standards Compliance Summary \u6807\u51c6\u5408\u89c4\u6027\u603b\u7ed3<\/h2>\n<div class=\"specs-box\">\n<h4>Applicable Standards \u9002\u7528\u6807\u51c6<\/h4>\n<div class=\"specs-list\">\n<span><strong>DIN VDE 0250-813:<\/strong> Trailing cables (medium voltage)<\/span>\n<span><strong>DIN VDE 0250-814:<\/strong> Flexible cables \u22640.6\/1 kV<\/span>\n<span><strong>DIN VDE 0295:<\/strong> Conductor classes<\/span>\n<span><strong>DIN VDE 0298-3\/4:<\/strong> Current carrying capacity<\/span>\n<span><strong>DIN VDE 0207-20:<\/strong> EPR insulation compounds<\/span>\n<span><strong>DIN VDE 0207-21:<\/strong> Thermosetting sheath compounds<\/span>\n<span><strong>IEC 60228:<\/strong> Conductors of insulated cables<\/span>\n<span><strong>EN 60332-1-2:<\/strong> Flame propagation test<\/span>\n<span><strong>HD 620 S2:<\/strong> Distribution cables 3.6\/6 kV to 20.8\/36 kV<\/span>\n<\/div>\n<\/div>\n<p class=\"source-ref\">References: <a href=\"https:\/\/feichuncables.com\/blog\/what-is-din-vde-0250-reeling-cables\/\" rel=\"nofollow noopener\" target=\"_blank\">Feichun Cables &#8211; DIN VDE 0250 Overview<\/a> | <a href=\"https:\/\/www.prysmian.com\/sites\/default\/files\/business_markets\/markets\/downloads\/datasheets\/Medium-Voltage-Round.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Prysmian &#8211; Medium Voltage Reeling Cables<\/a><\/p>\n<\/section>\n\n<section class=\"contact-section\">\n<h3>Contact Anhui Feichun Special Cable Co., Ltd. \u8054\u7cfb\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/h3>\n<p>For technical consultation on RHEYFIRM\u00ae equivalent cables, custom Kevlar-reinforced cable solutions, or project-specific engineering support, our experienced team is ready to assist.<\/p>\n<p>\u5982\u9700RHEYFIRM\u00ae\u540c\u7b49\u7535\u7f06\u6280\u672f\u54a8\u8be2\u3001\u5b9a\u5236\u51ef\u592b\u62c9\u52a0\u5f3a\u7535\u7f06\u65b9\u6848\u6216\u9879\u76ee\u5de5\u7a0b\u652f\u6301\uff0c\u6b22\u8fce\u8054\u7cfb\u6211\u4eec\u7684\u4e13\u4e1a\u56e2\u961f\u3002<\/p>\n<div class=\"contact-grid\">\n<div class=\"contact-item\">\n<strong>Technical Support \u6280\u672f\u652f\u6301<\/strong>\n<a href=\"mailto:tech@feichuncables.com\">tech@feichuncables.com<\/a>\n<\/div>\n<div class=\"contact-item\">\n<strong>Sales &#8211; Zihao Yang \u9500\u552e-\u6768\u5b50\u8c6a<\/strong>\n<a href=\"mailto:zihao.yang@feichuncables.com\">zihao.yang@feichuncables.com<\/a>\n<\/div>\n<div class=\"contact-item\">\n<strong>Sales &#8211; Ziyu Huang \u9500\u552e-\u9ec4\u5b50\u7389<\/strong>\n<a href=\"mailto:ziyu.huang@feichuncables.com\">ziyu.huang@feichuncables.com<\/a>\n<\/div>\n<div class=\"contact-item\">\n<strong>WhatsApp \u5373\u65f6\u901a\u8baf<\/strong>\n<a href=\"https:\/\/wa.me\/8613855123218\" rel=\"nofollow noopener\" target=\"_blank\">+86 138 5512 3218<\/a>\n<\/div>\n<\/div>\n<\/section>\n\n<section class=\"references\">\n<h3>References &#038; External Sources \u53c2\u8003\u8d44\u6599\u4e0e\u5916\u90e8\u6765\u6e90<\/h3>\n<ol class=\"ref-list\">\n<li>Eland Cables. &#8220;DIN VDE 0250 Standard Cable.&#8221; <a href=\"https:\/\/www.elandcables.com\/electrical-cable-and-accessories\/cables-by-standard\/vde0250-cable\" rel=\"nofollow noopener\" target=\"_blank\">elandcables.com<\/a><\/li>\n<li>CSE Industrial Electrical Distributors. &#8220;RHEYFIRM\u00ae(RTS) (N)TSCGEWTOEUS Cable.&#8221; <a href=\"https:\/\/www.cse-distributors.co.uk\/cable\/nexans-handling-cable\/rheyfirmrts-ntscgewtoeus-cable.html\" rel=\"nofollow noopener\" target=\"_blank\">cse-distributors.co.uk<\/a><\/li>\n<li>Nexans Deutschland GmbH. &#8220;RHEYFIRM\u00ae (RTS) R-(N)TSCGEWTOEUS 8.7\/15 kV.&#8221; <a href=\"https:\/\/www.nexans.de\/eservice\/Germany-en\/navigate_342578\/RHEYFIRM_RTS_R_N_TSCGEWTOEUS_8_7_15_kV.html\" rel=\"nofollow noopener\" target=\"_blank\">nexans.de<\/a><\/li>\n<li>DuPont. &#8220;Kevlar\u00ae Ropes and Cables Applications.&#8221; <a href=\"https:\/\/www.dupont.com\/fabrics-fibers-and-nonwovens\/ropes-cables.html\" rel=\"nofollow noopener\" target=\"_blank\">dupont.com<\/a><\/li>\n<li>Tratos Group. &#8220;Mining and Tunneling Cables &#8211; DIN VDE 250 Part 813.&#8221; <a href=\"https:\/\/tratosgroup.com\/products\/standards\/others\/din-vde-250-part-813\/\" rel=\"nofollow noopener\" target=\"_blank\">tratosgroup.com<\/a><\/li>\n<li>DeRegt Cables. &#8220;Steel vs. Aramid Fibre &#8211; Cable Solution Comparison.&#8221; <a href=\"https:\/\/blog.deregtcables.com\/news\/steel-vs.-aramid-fibre-what-is-the-best-cable-solution\" rel=\"nofollow noopener\" target=\"_blank\">deregtcables.com<\/a><\/li>\n<li>Prysmian Group. &#8220;PROTOLON Medium Voltage Reeling Cables &#8211; DIN VDE 0250-813.&#8221; <a href=\"https:\/\/www.prysmian.com\/sites\/default\/files\/business_markets\/markets\/downloads\/datasheets\/Medium-Voltage-Round.pdf\" rel=\"nofollow noopener\" target=\"_blank\">prysmian.com<\/a><\/li>\n<li>CED Elevator. &#8220;Traveling Cable Selection Guide.&#8221; <a href=\"https:\/\/www.cedelevator.com\/cable-selector-guide-choosing-the-right-traveling-cable-for-the-job\/\" rel=\"nofollow noopener\" target=\"_blank\">cedelevator.com<\/a><\/li>\n<\/ol>\n<\/section>\n\n<footer>\n<p>\u00a9 2026 Anhui Feichun Special Cable Co., Ltd. \u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8 | All Rights Reserved<\/p>\n<p>This technical document is provided for informational purposes. Specifications subject to change. Contact engineering team for project-specific requirements.<\/p>\n<\/footer>\n<\/div>\n<\/body>\n<\/html>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"RHEYFIRM cable, RHEYFIRM RTS, RHEYFIRM RS, NTSCGEWTOEUS, NTSKCGECW\u00d6U,\nKevlar reinforced cable, aramid fiber cable, DIN VDE 0250-813,\nmedium voltage reeling cable, ultra-long vertical travel cable,\ndeep shaft mining cable, mine hoist cable, STS crane cable,\nship-to-shore crane cable, RMG crane cable, trailing cable,\nEPR insulated cable, rubber sheathed flexible cable,\n\u9ad8\u538b\u5377\u7b52\u7535\u7f06, \u51ef\u592b\u62c9\u52a0\u5f3a\u7535\u7f06, \u77ff\u7528\u7535\u7f06, \u8d77\u91cd\u673a\u7535\u7f06,\nNexans equivalent cable, Prysmian alternative cable,\ncoal cutter cable, tunnel boring machine cable, TBM cable,\nelevator traveling cable, high-rise elevator cable,\nsteel core vs Kevlar cable, aramid strength member cable,\nDIN VDE 0250 Part 813 compliant, VDE mining cable,\n6\/10kV reeling cable, 12\/20kV trailing cable, 18\/30kV power cable,\nopen-pit mining cable, underground mining cable,\nflexible power cable for cranes, material handling cable,\ntinned copper conductor cable, flame retardant mining cable,\noil resistant reeling cable, ozone resistant cable,\nFeichun special cable, \u5b89\u5fbd\u98de\u7eaf\u7535\u7f06, \u98de\u7eaf\u7279\u79cd\u7535\u7f06,\nNSSHCGEW\u00d6U cable, continuous miner cable, dragline cable,\nstacker reclaimer cable, excavator power cable","protected":false},"author":1,"featured_media":6588,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[46,66,56],"tags":[29080,34247,12148,26561,38515,1684,1114,5026,41862,548,1079,41857,820,1499,3826,3726,38670,41858,26350,1092,166,2067,38513,41863,41844,41853,5537,1678,788,41856,26393,41854,26458,2606,1311,2401,995,41861,2604,227,919,994,228,41855,1091,6450,41860,3230,11984,22977,36893,41859],"class_list":["post-6587","post","type-post","status-publish","format-standard","has-post-thumbnail","category-cable-for-shore-connection-systems","category-common-problems-encountered-in-cable-applications","category-reeling-cable","tag-12-20kv-trailing-cable","tag-18-30kv-power-cable","tag-6-10kv-reeling-cable","tag-aramid-fiber-cable","tag-aramid-strength-member-cable","tag-coal-cutter-cable","tag-continuous-miner-cable","tag-deep-shaft-mining-cable","tag-din-vde-0250-part-813-compliant","tag-din-vde-0250-813","tag-dragline-cable","tag-elevator-traveling-cable","tag-epr-insulated-cable","tag-excavator-power-cable","tag-feichun-special-cable","tag-flame-retardant-mining-cable-2","tag-flexible-power-cable-for-cranes","tag-high-rise-elevator-cable","tag-kevlar-reinforced-cable","tag-material-handling-cable","tag-medium-voltage-reeling-cable","tag-mine-hoist-cable","tag-nexans-equivalent-cable","tag-nsshcgewou-cable","tag-ntscgewtoeus","tag-ntskcgecwou","tag-oil-resistant-reeling-cable","tag-open-pit-mining-cable","tag-ozone-resistant-cable","tag-prysmian-alternative-cable","tag-rheyfirm-cable","tag-rheyfirm-rs","tag-rheyfirm-rts","tag-rmg-crane-cable","tag-rubber-sheathed-flexible-cable","tag-ship-to-shore-crane-cable-2","tag-stacker-reclaimer-cable","tag-steel-core-vs-kevlar-cable","tag-sts-crane-cable","tag-tbm-cable","tag-tinned-copper-conductor-cable","tag-trailing-cable","tag-tunnel-boring-machine-cable","tag-ultra-long-vertical-travel-cable","tag-underground-mining-cable","tag-vde-mining-cable","tag-41860","tag-3230","tag-11984","tag-22977","tag-36893","tag-41859","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/6587","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=6587"}],"version-history":[{"count":1,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/6587\/revisions"}],"predecessor-version":[{"id":6589,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/6587\/revisions\/6589"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/6588"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=6587"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=6587"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=6587"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}