{"id":6568,"date":"2026-02-09T11:43:33","date_gmt":"2026-02-09T03:43:33","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=6568"},"modified":"2026-02-09T11:43:40","modified_gmt":"2026-02-09T03:43:40","slug":"rheyfirm-rs-vs-rheyfirm-rts-when-should-you-choose-the-reduced-diameter-version","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/rheyfirm-rs-vs-rheyfirm-rts-when-should-you-choose-the-reduced-diameter-version\/","title":{"rendered":"RHEYFIRM\u00ae (RS) vs. RHEYFIRM\u00ae (RTS): When Should You Choose the &#8220;Reduced Diameter&#8221; Version?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Space-Constrained Cable Reel Applications \u2014 \u7a7a\u95f4\u53d7\u9650\u5377\u7b52\u7535\u7f06\u9009\u578b\u6280\u672f\u6307\u5357<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-dominant-color=\"718790\" data-has-transparency=\"false\" style=\"--dominant-color: #718790;\" loading=\"lazy\" decoding=\"async\" width=\"541\" height=\"628\" sizes=\"auto, (max-width: 541px) 100vw, 541px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-765-541x628.avif\" alt=\"\" class=\"wp-image-6569 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-765-541x628.avif 541w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-765-258x300.avif 258w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-765-400x465.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-765.avif 655w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n<meta name=\"description\" content=\"Technical comparison of RHEYFIRM\u00ae (RS) vs RHEYFIRM\u00ae (RTS) reduced diameter reeling cables for space-constrained drum applications. Professional guide from Anhui Feichun Special Cable.\">\n<meta name=\"keywords\" content=\"RHEYFIRM RS, RHEYFIRM RTS, reduced diameter cable, reeling cable, DIN VDE 0250-813, crane cable, mining cable\">\n<title>RHEYFIRM\u00ae (RS) vs (RTS): Reduced Diameter Cable Selection | Feichun Cable<\/title>\n<style>\n:root {\n  --bg-primary: #ffffff;\n  --bg-secondary: #f7f8fa;\n  --bg-table-header: #1e3a5f;\n  --text-primary: #1a202c;\n  --text-secondary: #4a5568;\n  --text-muted: #718096;\n  --border-color: #e2e8f0;\n  --accent-color: #2563eb;\n  --accent-hover: #1d4ed8;\n  --table-stripe: #f1f5f9;\n  --highlight: #eff6ff;\n  --success: #059669;\n  --warning: #d97706;\n}\n@media (prefers-color-scheme: dark) {\n  :root {\n    --bg-primary: #1a202c;\n    --bg-secondary: #2d3748;\n    --bg-table-header: #1e40af;\n    --text-primary: #e2e8f0;\n    --text-secondary: #a0aec0;\n    --text-muted: #718096;\n    --border-color: #4a5568;\n    --accent-color: #60a5fa;\n    --accent-hover: #3b82f6;\n    --table-stripe: #2d3748;\n    --highlight: #1e3a5f;\n    --success: #10b981;\n    --warning: #fbbf24;\n  }\n}\n* { margin: 0; padding: 0; box-sizing: border-box; }\nbody {\n  font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Arial, sans-serif;\n  background-color: var(--bg-primary);\n  color: var(--text-primary);\n  line-height: 1.7;\n  font-size: 16px;\n}\n.container { max-width: 1000px; margin: 0 auto; padding: 20px; }\nheader {\n  border-bottom: 3px solid var(--accent-color);\n  padding-bottom: 20px;\n  margin-bottom: 30px;\n}\n.company-info {\n  display: flex;\n  flex-wrap: wrap;\n  justify-content: space-between;\n  align-items: center;\n  gap: 15px;\n  margin-bottom: 20px;\n}\n.company-name { font-size: 1.1em; font-weight: 600; color: var(--accent-color); }\n.company-name-cn { font-size: 0.9em; color: var(--text-muted); }\nh1 {\n  font-size: 1.7em;\n  color: var(--text-primary);\n  margin-bottom: 10px;\n  font-weight: 700;\n  line-height: 1.3;\n}\nh1 span { display: block; font-size: 0.55em; color: var(--text-secondary); font-weight: 400; margin-top: 8px; }\nh2 {\n  font-size: 1.3em;\n  color: var(--accent-color);\n  margin: 35px 0 15px 0;\n  padding-bottom: 8px;\n  border-bottom: 2px solid var(--border-color);\n}\nh2 .cn { font-size: 0.75em; color: var(--text-muted); font-weight: 400; display: block; }\nh3 { font-size: 1.1em; color: var(--text-primary); margin: 25px 0 12px 0; }\np { margin-bottom: 15px; color: var(--text-secondary); text-align: justify; }\n.cn-note { font-size: 0.85em; color: var(--text-muted); font-style: italic; margin-top: -10px; margin-bottom: 15px; }\ntable {\n  width: 100%;\n  border-collapse: collapse;\n  margin: 20px 0;\n  font-size: 0.9em;\n  background: var(--bg-primary);\n  border: 1px solid var(--border-color);\n}\nth {\n  background: var(--bg-table-header);\n  color: #ffffff;\n  padding: 12px 10px;\n  text-align: left;\n  font-weight: 600;\n  font-size: 0.9em;\n}\ntd {\n  padding: 10px;\n  border-bottom: 1px solid var(--border-color);\n  vertical-align: top;\n}\ntr:nth-child(even) { background: var(--table-stripe); }\ntr:hover { background: var(--highlight); }\n.param-name { font-weight: 600; color: var(--text-primary); }\n.param-cn { font-size: 0.8em; color: var(--text-muted); display: block; }\n.highlight-cell { background: var(--highlight); font-weight: 500; }\n.advantage { color: var(--success); font-weight: 600; }\n.consideration { color: var(--warning); font-weight: 500; }\n.reference-section {\n  background: var(--bg-secondary);\n  padding: 20px;\n  border-radius: 6px;\n  margin: 30px 0;\n}\n.reference-section h3 { margin-top: 0; }\n.ref-list { list-style: decimal; padding-left: 20px; }\n.ref-list li { margin-bottom: 8px; font-size: 0.9em; color: var(--text-secondary); }\n.ref-list a { color: var(--accent-color); text-decoration: none; word-break: break-all; }\n.ref-list a:hover { text-decoration: underline; }\n.contact-section {\n  background: var(--bg-table-header);\n  color: #ffffff;\n  padding: 25px;\n  border-radius: 6px;\n  margin: 30px 0;\n}\n.contact-section h3 { color: #ffffff; margin-top: 0; border: none; }\n.contact-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(200px, 1fr));\n  gap: 15px;\n  margin-top: 15px;\n}\n.contact-item { font-size: 0.95em; }\n.contact-item strong { display: block; margin-bottom: 3px; opacity: 0.9; }\n.contact-item a { color: #93c5fd; text-decoration: none; }\n.contact-item a:hover { text-decoration: underline; }\n.spec-note {\n  background: var(--highlight);\n  border-left: 4px solid var(--accent-color);\n  padding: 15px;\n  margin: 20px 0;\n  font-size: 0.95em;\n}\n.decision-box {\n  background: var(--bg-secondary);\n  border: 2px solid var(--accent-color);\n  border-radius: 8px;\n  padding: 20px;\n  margin: 25px 0;\n}\n.decision-box h4 {\n  color: var(--accent-color);\n  margin-bottom: 12px;\n  font-size: 1.05em;\n}\n.formula-box {\n  background: var(--bg-secondary);\n  border: 1px solid var(--border-color);\n  border-radius: 4px;\n  padding: 15px;\n  margin: 15px 0;\n  font-family: 'Courier New', monospace;\n  font-size: 0.9em;\n}\n.disclaimer {\n  font-size: 0.8em;\n  color: var(--text-muted);\n  border-top: 1px solid var(--border-color);\n  padding-top: 20px;\n  margin-top: 40px;\n}\nfooter {\n  text-align: center;\n  padding: 20px;\n  border-top: 1px solid var(--border-color);\n  margin-top: 30px;\n  font-size: 0.85em;\n  color: var(--text-muted);\n}\n@media (max-width: 768px) {\n  .container { padding: 15px; }\n  h1 { font-size: 1.4em; }\n  table { font-size: 0.8em; }\n  th, td { padding: 8px 6px; }\n  .contact-grid { grid-template-columns: 1fr; }\n}\n<\/style>\n<\/head>\n<body>\n<div class=\"container\">\n<header>\n<div class=\"company-info\">\n<div>\n<div class=\"company-name\">Anhui Feichun Special Cable Co., Ltd.<\/div>\n<div class=\"company-name-cn\">\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/div>\n<\/div>\n<div style=\"font-size:0.85em;color:var(--text-muted);\">Professional Reeling Cable Solutions<br><span style=\"font-size:0.9em;\">\u4e13\u4e1a\u5377\u7b52\u7535\u7f06\u89e3\u51b3\u65b9\u6848<\/span><\/div>\n<\/div>\n<h1>RHEYFIRM\u00ae (RS) vs. RHEYFIRM\u00ae (RTS): When Should You Choose the &#8220;Reduced Diameter&#8221; Version?<span>Space-Constrained Cable Reel Applications \u2014 \u7a7a\u95f4\u53d7\u9650\u5377\u7b52\u7535\u7f06\u9009\u578b\u6280\u672f\u6307\u5357<\/span><\/h1>\n<\/header>\n\n<article>\n<section>\n<h2>Introduction to RHEYFIRM\u00ae Reeling Cables <span class=\"cn\">RHEYFIRM\u00ae\u5377\u7b52\u7535\u7f06\u7b80\u4ecb<\/span><\/h2>\n<p>RHEYFIRM\u00ae represents Nexans&#8217; premium brand of flexible medium voltage reeling cables designed for high and extreme mechanical stress applications. These cables are engineered especially for torsional stress and high reeling speeds, with capability for deflection into different planes. The choice between standard (RS) and reduced diameter (RTS) versions significantly impacts reel capacity, installation flexibility, and overall system performance in space-constrained environments.<\/p>\n<p class=\"cn-note\">RHEYFIRM\u00ae\u662fNexans\u9488\u5bf9\u9ad8\u5f3a\u5ea6\u673a\u68b0\u5e94\u529b\u5e94\u7528\u8bbe\u8ba1\u7684\u4f18\u8d28\u67d4\u6027\u4e2d\u538b\u5377\u7b52\u7535\u7f06\u54c1\u724c\uff0c\u4e13\u4e3a\u626d\u8f6c\u5e94\u529b\u548c\u9ad8\u901f\u5377\u7ed5\u5de5\u51b5\u8bbe\u8ba1\u3002\u6807\u51c6\u578b(RS)\u4e0e\u51cf\u5f84\u578b(RTS)\u7684\u9009\u62e9\u5bf9\u5377\u7b52\u5bb9\u91cf\u548c\u7cfb\u7edf\u6027\u80fd\u6709\u91cd\u8981\u5f71\u54cd\u3002<\/p>\n\n<div class=\"spec-note\">\n<strong>Key Applications \u4e3b\u8981\u5e94\u7528:<\/strong> Ship-to-Shore Cranes (STS), Rail Mounted Gantry Cranes (RMG), Ship Unloaders, Stacker Reclaimers, Excavators, Draglines, Mobile Crushers, Open-cast and Underground Mining Equipment\n<\/div>\n<\/section>\n\n<section>\n<h2>Understanding the RS vs. RTS Designation <span class=\"cn\">RS\u4e0eRTS\u547d\u540d\u89e3\u6790<\/span><\/h2>\n<p>The designation system for RHEYFIRM\u00ae cables follows Nexans&#8217; systematic nomenclature where &#8220;RS&#8221; indicates Regular\/Standard construction and &#8220;RTS&#8221; denotes Reduced Thickness Sheath or Reduced diameter Total construction. The RTS version achieves diameter reduction through optimized insulation wall thickness, compact stranding geometry, and thinner protective layers while maintaining equivalent electrical performance.<\/p>\n<p class=\"cn-note\">RHEYFIRM\u00ae\u7535\u7f06\u547d\u540d\u7cfb\u7edf\u4e2d\uff0c&#8221;RS&#8221;\u8868\u793a\u5e38\u89c4\/\u6807\u51c6\u7ed3\u6784\uff0c&#8221;RTS&#8221;\u8868\u793a\u51cf\u8584\u62a4\u5957\u6216\u6574\u4f53\u51cf\u5f84\u7ed3\u6784\u3002RTS\u7248\u672c\u901a\u8fc7\u4f18\u5316\u7edd\u7f18\u539a\u5ea6\u3001\u7d27\u51d1\u7ede\u5408\u51e0\u4f55\u548c\u66f4\u8584\u4fdd\u62a4\u5c42\u5b9e\u73b0\u51cf\u5f84\uff0c\u540c\u65f6\u4fdd\u6301\u76f8\u540c\u7535\u6c14\u6027\u80fd\u3002<\/p>\n\n<h3>Type Designation Codes \u578b\u53f7\u547d\u540d\u4ee3\u7801<\/h3>\n<table>\n<thead>\n<tr><th>Code \u4ee3\u7801<\/th><th>Meaning \u542b\u4e49<\/th><th>Description \u8bf4\u660e<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td class=\"param-name\">(N)<\/td><td>Recognized type \u8ba4\u53ef\u578b\u53f7<\/td><td>VDE registered construction<\/td><\/tr>\n<tr><td class=\"param-name\">T<\/td><td>Trailing cable \u62d6\u66f3\u7535\u7f06<\/td><td>For mobile\/reeling applications<\/td><\/tr>\n<tr><td class=\"param-name\">SC<\/td><td>Screened cores \u5c4f\u853d\u82af\u7ebf<\/td><td>Individual core screening<\/td><\/tr>\n<tr><td class=\"param-name\">GE<\/td><td>Earth conductors \u63a5\u5730\u82af<\/td><td>Integrated ground conductors<\/td><\/tr>\n<tr><td class=\"param-name\">W<\/td><td>Weather resistant \u8010\u5019<\/td><td>UV, moisture, ozone resistant<\/td><\/tr>\n<tr><td class=\"param-name\">T (suffix)<\/td><td>Torsion resistant \u6297\u626d<\/td><td>Anti-torsion braid reinforcement<\/td><\/tr>\n<tr><td class=\"param-name\">O<\/td><td>Oil resistant \u8010\u6cb9<\/td><td>5GM5 oil-resistant sheath<\/td><\/tr>\n<tr><td class=\"param-name\">EU<\/td><td>European \u6b27\u6d32\u6807\u51c6<\/td><td>DIN VDE compliance<\/td><\/tr>\n<tr><td class=\"param-name\">S<\/td><td>Heavy duty sheath \u91cd\u578b\u62a4\u5957<\/td><td>Chlorinated rubber compound<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n\n<section>\n<h2>Technical Standards Compliance <span class=\"cn\">\u6280\u672f\u6807\u51c6\u7b26\u5408\u6027<\/span><\/h2>\n\n<table>\n<thead>\n<tr><th>Standard \u6807\u51c6<\/th><th>Scope \u9002\u7528\u8303\u56f4<\/th><th>Key Requirements \u5173\u952e\u8981\u6c42<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td class=\"param-name\">DIN VDE 0250-813<span class=\"param-cn\">\u4e3b\u8981\u6267\u884c\u6807\u51c6<\/span><\/td><td>Medium voltage trailing cables 3.6\/6kV to 18\/30kV<\/td><td>Construction, dimensions, testing<\/td><\/tr>\n<tr><td class=\"param-name\">DIN VDE 0295<span class=\"param-cn\">\u5bfc\u4f53\u6807\u51c6<\/span><\/td><td>Conductor classes (Class 5\/6 flexible)<\/td><td>Stranding, resistance<\/td><\/tr>\n<tr><td class=\"param-name\">DIN VDE 0298-3\/4<span class=\"param-cn\">\u8f7d\u6d41\u91cf\u6807\u51c6<\/span><\/td><td>Current carrying capacity, installation<\/td><td>Derating factors, tensile loads<\/td><\/tr>\n<tr><td class=\"param-name\">DIN VDE 0207-20\/21<span class=\"param-cn\">\u7edd\u7f18\u62a4\u5957\u6750\u6599<\/span><\/td><td>EPR insulation, rubber sheath compounds<\/td><td>Material properties<\/td><\/tr>\n<tr><td class=\"param-name\">prEN 50363<span class=\"param-cn\">\u6b27\u6d32\u7535\u7f06\u6750\u6599<\/span><\/td><td>Insulating and sheathing materials<\/td><td>Fire, mechanical properties<\/td><\/tr>\n<tr><td class=\"param-name\">IEC 60332-1<span class=\"param-cn\">\u963b\u71c3\u6807\u51c6<\/span><\/td><td>Flame retardant testing<\/td><td>Vertical flame propagation<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n\n<section>\n<h2>RHEYFIRM\u00ae (RS) Standard Construction <span class=\"cn\">RHEYFIRM\u00ae (RS) \u6807\u51c6\u7ed3\u6784<\/span><\/h2>\n<p>The RHEYFIRM\u00ae (RS) standard version, designated (N)TSCGEWOEUS, provides robust construction with full-thickness insulation and sheath layers optimized for maximum durability in demanding applications. This design prioritizes mechanical protection and long service life over dimensional compactness.<\/p>\n\n<h3>Construction Details \u7ed3\u6784\u8be6\u60c5<\/h3>\n<table>\n<thead>\n<tr><th>Component \u7ec4\u4ef6<\/th><th>Material\/Specification \u6750\u6599\/\u89c4\u683c<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td class=\"param-name\">Conductor<span class=\"param-cn\">\u5bfc\u4f53<\/span><\/td><td>Copper, plain, flexible stranded Class 5 per IEC 60228\/DIN VDE 0295<\/td><\/tr>\n<tr><td class=\"param-name\">Conductor Screen<span class=\"param-cn\">\u5bfc\u4f53\u5c4f\u853d<\/span><\/td><td>Inner semi-conductive EPR layer<\/td><\/tr>\n<tr><td class=\"param-name\">Insulation<span class=\"param-cn\">\u7edd\u7f18\u5c42<\/span><\/td><td>High-grade EPR compound (\u22653GI3) per DIN VDE 0207-20<\/td><\/tr>\n<tr><td class=\"param-name\">Insulation Screen<span class=\"param-cn\">\u7edd\u7f18\u5c4f\u853d<\/span><\/td><td>Outer semi-conductive layer, easy-strip design (&#8220;RHEYSTRIP&#8221;)<\/td><\/tr>\n<tr><td class=\"param-name\">Core Assembly<span class=\"param-cn\">\u6210\u7f06<\/span><\/td><td>Power cores over semi-conductive rubber center with fillers<\/td><\/tr>\n<tr><td class=\"param-name\">Earth Conductor<span class=\"param-cn\">\u63a5\u5730\u5bfc\u4f53<\/span><\/td><td>Split protective conductor in interstices<\/td><\/tr>\n<tr><td class=\"param-name\">Inner Sheath<span class=\"param-cn\">\u5185\u62a4\u5957<\/span><\/td><td>Extruded GM1b synthetic rubber compound<\/td><\/tr>\n<tr><td class=\"param-name\">Reinforcement<span class=\"param-cn\">\u589e\u5f3a\u5c42<\/span><\/td><td>Embedded braid of high-tensile synthetic threads<\/td><\/tr>\n<tr><td class=\"param-name\">Outer Sheath<span class=\"param-cn\">\u5916\u62a4\u5957<\/span><\/td><td>Chlorinated heavy-duty rubber 5GM5, oil\/flame\/tear resistant, Red<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n\n<section>\n<h2>RHEYFIRM\u00ae (RTS) Reduced Diameter Construction <span class=\"cn\">RHEYFIRM\u00ae (RTS) \u51cf\u5f84\u7ed3\u6784<\/span><\/h2>\n<p>The RHEYFIRM\u00ae (RTS) reduced diameter version, designated (N)TSCGEWTOEUS, achieves significant diameter reduction through optimized construction while maintaining full electrical performance. This design is specifically engineered for applications where cable reel dimensions are constrained or where increased cable length per reel is required.<\/p>\n<p class=\"cn-note\">RHEYFIRM\u00ae (RTS)\u51cf\u5f84\u7248\u672c\u901a\u8fc7\u4f18\u5316\u7ed3\u6784\u5b9e\u73b0\u663e\u8457\u51cf\u5f84\uff0c\u540c\u65f6\u4fdd\u6301\u5b8c\u6574\u7535\u6c14\u6027\u80fd\u3002\u4e13\u4e3a\u5377\u7b52\u5c3a\u5bf8\u53d7\u9650\u6216\u9700\u8981\u589e\u52a0\u5355\u76d8\u7535\u7f06\u957f\u5ea6\u7684\u5e94\u7528\u8bbe\u8ba1\u3002<\/p>\n\n<h3>Diameter Reduction Methods \u51cf\u5f84\u65b9\u6cd5<\/h3>\n<table>\n<thead>\n<tr><th>Optimization Area \u4f18\u5316\u9886\u57df<\/th><th>Standard (RS) \u6807\u51c6\u578b<\/th><th>Reduced (RTS) \u51cf\u5f84\u578b<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td class=\"param-name\">Insulation Wall<span class=\"param-cn\">\u7edd\u7f18\u58c1\u539a<\/span><\/td><td>Full thickness per DIN VDE 0250-813<\/td><td class=\"highlight-cell\">Optimized minimum per standard allowance<\/td><\/tr>\n<tr><td class=\"param-name\">Conductor Stranding<span class=\"param-cn\">\u5bfc\u4f53\u7ede\u5408<\/span><\/td><td>Class 5 standard geometry<\/td><td class=\"highlight-cell\">Class 6 compact geometry where applicable<\/td><\/tr>\n<tr><td class=\"param-name\">Inner Sheath<span class=\"param-cn\">\u5185\u62a4\u5957<\/span><\/td><td>Standard thickness GM1b<\/td><td class=\"highlight-cell\">Reduced thickness with maintained properties<\/td><\/tr>\n<tr><td class=\"param-name\">Outer Sheath<span class=\"param-cn\">\u5916\u62a4\u5957<\/span><\/td><td>Full 5GM5 thickness<\/td><td class=\"highlight-cell\">Optimized thickness (T = Thin)<\/td><\/tr>\n<tr><td class=\"param-name\">Filler Design<span class=\"param-cn\">\u586b\u5145\u8bbe\u8ba1<\/span><\/td><td>Standard semi-conductive fillers<\/td><td class=\"highlight-cell\">Compact optimized filler geometry<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n\n<section>\n<h2>Dimensional Comparison <span class=\"cn\">\u5c3a\u5bf8\u5bf9\u6bd4<\/span><\/h2>\n\n<h3>Typical Outer Diameter Comparison (3\u00d795mm\u00b2 + 3\u00d750mm\u00b2\/3) \u5178\u578b\u5916\u5f84\u5bf9\u6bd4<\/h3>\n<table>\n<thead>\n<tr><th>Voltage Rating \u7535\u538b\u7b49\u7ea7<\/th><th>RS Diameter (approx.) \u6807\u51c6\u5916\u5f84<\/th><th>RTS Diameter (approx.) \u51cf\u5f84\u5916\u5f84<\/th><th>Reduction \u51cf\u5f84\u6bd4\u4f8b<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td class=\"param-name\">3.6\/6kV<\/td><td>~58mm<\/td><td class=\"highlight-cell\">~52mm<\/td><td class=\"advantage\">~10-12%<\/td><\/tr>\n<tr><td class=\"param-name\">6\/10kV<\/td><td>~65mm<\/td><td class=\"highlight-cell\">~58mm<\/td><td class=\"advantage\">~10-12%<\/td><\/tr>\n<tr><td class=\"param-name\">8.7\/15kV<\/td><td>~72mm<\/td><td class=\"highlight-cell\">~65mm<\/td><td class=\"advantage\">~10%<\/td><\/tr>\n<tr><td class=\"param-name\">12\/20kV<\/td><td>~82mm<\/td><td class=\"highlight-cell\">~74mm<\/td><td class=\"advantage\">~10%<\/td><\/tr>\n<tr><td class=\"param-name\">18\/30kV<\/td><td>~95mm<\/td><td class=\"highlight-cell\">~86mm<\/td><td class=\"advantage\">~9-10%<\/td><\/tr>\n<\/tbody>\n<\/table>\n<p class=\"cn-note\">\u6ce8\uff1a\u5b9e\u9645\u5c3a\u5bf8\u56e0\u622a\u9762\u79ef\u548c\u5177\u4f53\u914d\u7f6e\u800c\u5f02\uff0c\u4e0a\u8ff0\u6570\u636e\u4ec5\u4f9b\u53c2\u8003\u3002Actual dimensions vary by cross-section and configuration.<\/p>\n<\/section>\n\n<section>\n<h2>Impact on Cable Reel Capacity <span class=\"cn\">\u5bf9\u5377\u7b52\u5bb9\u91cf\u7684\u5f71\u54cd<\/span><\/h2>\n<p>The relationship between cable diameter and reel capacity follows a quadratic relationship. A 10% reduction in cable diameter results in approximately 20-25% increase in reel capacity, making the RTS version particularly valuable for space-constrained applications where maximizing cable length per reel is critical.<\/p>\n\n<div class=\"formula-box\">\n<strong>Reel Capacity Formula \u5377\u7b52\u5bb9\u91cf\u516c\u5f0f:<\/strong><br><br>\nL = (\u03c0 \u00d7 B \u00d7 (D\u00b2 &#8211; d\u00b2)) \/ (4 \u00d7 C\u00b2)<br><br>\nWhere \u5176\u4e2d: L = Cable length \u7535\u7f06\u957f\u5ea6 (m)<br>\nB = Traverse width \u5377\u7b52\u5bbd\u5ea6 (mm)<br>\nD = Flange diameter \u6cd5\u5170\u76f4\u5f84 (mm)<br>\nd = Drum core diameter \u5377\u7b52\u82af\u5f84 (mm)<br>\nC = Cable outer diameter \u7535\u7f06\u5916\u5f84 (mm)\n<\/div>\n\n<h3>Capacity Increase Example \u5bb9\u91cf\u589e\u52a0\u793a\u4f8b<\/h3>\n<table>\n<thead>\n<tr><th>Parameter \u53c2\u6570<\/th><th>RS Version (58mm OD)<\/th><th>RTS Version (52mm OD)<\/th><th>Difference \u5dee\u5f02<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td class=\"param-name\">Reel Dimensions<span class=\"param-cn\">\u5377\u7b52\u5c3a\u5bf8<\/span><\/td><td colspan=\"3\">Flange: 2000mm, Drum: 800mm, Traverse: 600mm<\/td><\/tr>\n<tr><td class=\"param-name\">Calculated Capacity<span class=\"param-cn\">\u8ba1\u7b97\u5bb9\u91cf<\/span><\/td><td>~520m<\/td><td class=\"highlight-cell\">~650m<\/td><td class=\"advantage\">+25%<\/td><\/tr>\n<tr><td class=\"param-name\">Weight per 100m<span class=\"param-cn\">\u6bcf\u767e\u7c73\u91cd\u91cf<\/span><\/td><td>~1,850kg<\/td><td class=\"highlight-cell\">~1,720kg<\/td><td class=\"advantage\">-7%<\/td><\/tr>\n<tr><td class=\"param-name\">Min. Bending Radius<span class=\"param-cn\">\u6700\u5c0f\u5f2f\u66f2\u534a\u5f84<\/span><\/td><td>12\u00d7 OD = 696mm<\/td><td class=\"highlight-cell\">12\u00d7 OD = 624mm<\/td><td class=\"advantage\">-10%<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n\n<section>\n<h2>Performance Comparison <span class=\"cn\">\u6027\u80fd\u5bf9\u6bd4<\/span><\/h2>\n\n<table>\n<thead>\n<tr><th>Parameter \u53c2\u6570<\/th><th>RHEYFIRM\u00ae (RS)<\/th><th>RHEYFIRM\u00ae (RTS)<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td class=\"param-name\">Electrical Performance<span class=\"param-cn\">\u7535\u6c14\u6027\u80fd<\/span><\/td><td>Full rated voltage\/current<\/td><td>Equivalent rated voltage\/current<\/td><\/tr>\n<tr><td class=\"param-name\">Max. Conductor Temp.<span class=\"param-cn\">\u6700\u9ad8\u5bfc\u4f53\u6e29\u5ea6<\/span><\/td><td>90\u00b0C continuous<\/td><td>90\u00b0C continuous<\/td><\/tr>\n<tr><td class=\"param-name\">Short-circuit Temp.<span class=\"param-cn\">\u77ed\u8def\u6e29\u5ea6<\/span><\/td><td>250\u00b0C (5s)<\/td><td>250\u00b0C (5s)<\/td><\/tr>\n<tr><td class=\"param-name\">Max. Tensile Load<span class=\"param-cn\">\u6700\u5927\u62c9\u529b<\/span><\/td><td class=\"highlight-cell\">Up to 30 N\/mm\u00b2<\/td><td>Up to 30 N\/mm\u00b2<\/td><\/tr>\n<tr><td class=\"param-name\">Max. Reeling Speed<span class=\"param-cn\">\u6700\u9ad8\u5377\u7ed5\u901f\u5ea6<\/span><\/td><td>Up to 240 m\/min<\/td><td>Up to 240 m\/min<\/td><\/tr>\n<tr><td class=\"param-name\">Mechanical Protection<span class=\"param-cn\">\u673a\u68b0\u4fdd\u62a4<\/span><\/td><td class=\"highlight-cell\">Maximum (full sheath)<\/td><td>Adequate (optimized sheath)<\/td><\/tr>\n<tr><td class=\"param-name\">Abrasion Resistance<span class=\"param-cn\">\u8010\u78e8\u6027<\/span><\/td><td class=\"highlight-cell\">Superior<\/td><td>Good<\/td><\/tr>\n<tr><td class=\"param-name\">Service Life (typical)<span class=\"param-cn\">\u5178\u578b\u4f7f\u7528\u5bff\u547d<\/span><\/td><td class=\"highlight-cell\">15-20 years<\/td><td>12-18 years<\/td><\/tr>\n<tr><td class=\"param-name\">Reel Space Efficiency<span class=\"param-cn\">\u5377\u7b52\u7a7a\u95f4\u6548\u7387<\/span><\/td><td>Standard<\/td><td class=\"highlight-cell\">+20-25% capacity<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n\n<section>\n<h2>When to Choose RTS (Reduced Diameter) <span class=\"cn\">\u4f55\u65f6\u9009\u62e9RTS\u51cf\u5f84\u578b<\/span><\/h2>\n\n<div class=\"decision-box\">\n<h4>\u2713 Choose RHEYFIRM\u00ae (RTS) When \u9009\u62e9RTS\u7684\u60c5\u51b5:<\/h4>\n<table>\n<tbody>\n<tr><td class=\"param-name\">Space-Constrained Reels<span class=\"param-cn\">\u5377\u7b52\u7a7a\u95f4\u53d7\u9650<\/span><\/td><td>Existing reel dimensions cannot accommodate standard cable length requirements<\/td><\/tr>\n<tr><td class=\"param-name\">Retrofit Applications<span class=\"param-cn\">\u6539\u9020\u5e94\u7528<\/span><\/td><td>Replacing cables on existing equipment where reel cannot be enlarged<\/td><\/tr>\n<tr><td class=\"param-name\">Extended Travel Distance<span class=\"param-cn\">\u5ef6\u957f\u884c\u7a0b\u8ddd\u79bb<\/span><\/td><td>Application requires longer cable run than standard construction allows<\/td><\/tr>\n<tr><td class=\"param-name\">Weight Optimization<span class=\"param-cn\">\u91cd\u91cf\u4f18\u5316<\/span><\/td><td>Reel weight capacity is limited; lighter cable preferred<\/td><\/tr>\n<tr><td class=\"param-name\">Bending Radius Limits<span class=\"param-cn\">\u5f2f\u66f2\u534a\u5f84\u9650\u5236<\/span><\/td><td>Drum diameter is fixed and smaller bending radius is beneficial<\/td><\/tr>\n<tr><td class=\"param-name\">High-Speed STS Cranes<span class=\"param-cn\">\u9ad8\u901f\u5cb8\u6865<\/span><\/td><td>Modern fast-cycling cranes with compact cable reel housings<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<div class=\"decision-box\">\n<h4>\u2713 Choose RHEYFIRM\u00ae (RS) Standard When \u9009\u62e9RS\u6807\u51c6\u578b\u7684\u60c5\u51b5:<\/h4>\n<table>\n<tbody>\n<tr><td class=\"param-name\">New Installations<span class=\"param-cn\">\u65b0\u5efa\u9879\u76ee<\/span><\/td><td>Reel can be sized appropriately for standard cable dimensions<\/td><\/tr>\n<tr><td class=\"param-name\">Harsh Environments<span class=\"param-cn\">\u6076\u52a3\u73af\u5883<\/span><\/td><td>Maximum mechanical protection required (mining, abrasive conditions)<\/td><\/tr>\n<tr><td class=\"param-name\">Extended Service Life<span class=\"param-cn\">\u5ef6\u957f\u4f7f\u7528\u5bff\u547d<\/span><\/td><td>Premium durability and longer maintenance intervals preferred<\/td><\/tr>\n<tr><td class=\"param-name\">High Abrasion Exposure<span class=\"param-cn\">\u9ad8\u78e8\u635f\u66b4\u9732<\/span><\/td><td>Cable route includes significant abrasive contact points<\/td><\/tr>\n<tr><td class=\"param-name\">Budget Priority<span class=\"param-cn\">\u9884\u7b97\u4f18\u5148<\/span><\/td><td>Standard construction typically more cost-effective<\/td><\/tr>\n<tr><td class=\"param-name\">Mining Applications<span class=\"param-cn\">\u91c7\u77ff\u5e94\u7528<\/span><\/td><td>Excavators, draglines, mobile crushers in open-pit mining<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/section>\n\n<section>\n<h2>Application-Specific Recommendations <span class=\"cn\">\u5e94\u7528\u7279\u5b9a\u5efa\u8bae<\/span><\/h2>\n\n<table>\n<thead>\n<tr><th>Application \u5e94\u7528<\/th><th>Recommended \u63a8\u8350\u578b\u53f7<\/th><th>Rationale \u7406\u7531<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td class=\"param-name\">Ship-to-Shore Cranes (STS)<span class=\"param-cn\">\u5cb8\u8fb9\u96c6\u88c5\u7bb1\u8d77\u91cd\u673a<\/span><\/td><td class=\"highlight-cell\">RTS preferred<\/td><td>Space constraints in boom housing, high cycling speed<\/td><\/tr>\n<tr><td class=\"param-name\">Rail Mounted Gantry (RMG)<span class=\"param-cn\">\u8f68\u9053\u5f0f\u9f99\u95e8\u540a<\/span><\/td><td>RS or RTS<\/td><td>Depends on reel design; RTS for compact systems<\/td><\/tr>\n<tr><td class=\"param-name\">Rubber Tired Gantry (RTG)<span class=\"param-cn\">\u8f6e\u80ce\u5f0f\u9f99\u95e8\u540a<\/span><\/td><td class=\"highlight-cell\">RTS preferred<\/td><td>Mobile unit weight optimization important<\/td><\/tr>\n<tr><td class=\"param-name\">Ship Unloader<span class=\"param-cn\">\u5378\u8239\u673a<\/span><\/td><td>RS or RTS<\/td><td>Application-specific based on travel length<\/td><\/tr>\n<tr><td class=\"param-name\">Stacker Reclaimer<span class=\"param-cn\">\u5806\u53d6\u6599\u673a<\/span><\/td><td class=\"highlight-cell\">RS preferred<\/td><td>Harsh abrasive environment, durability priority<\/td><\/tr>\n<tr><td class=\"param-name\">Mining Excavator<span class=\"param-cn\">\u77ff\u7528\u6316\u6398\u673a<\/span><\/td><td class=\"highlight-cell\">RS preferred<\/td><td>Extreme mechanical stress, maximum protection needed<\/td><\/tr>\n<tr><td class=\"param-name\">Mobile Crusher<span class=\"param-cn\">\u79fb\u52a8\u7834\u788e\u673a<\/span><\/td><td class=\"highlight-cell\">RS preferred<\/td><td>Abrasive dust environment, impact resistance<\/td><\/tr>\n<tr><td class=\"param-name\">Festoon Systems<span class=\"param-cn\">\u60ac\u6302\u7cfb\u7edf<\/span><\/td><td>RTS advantageous<\/td><td>Reduced weight beneficial for trolley systems<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n\n<section>\n<h2>Installation Considerations <span class=\"cn\">\u5b89\u88c5\u6ce8\u610f\u4e8b\u9879<\/span><\/h2>\n\n<table>\n<thead>\n<tr><th>Parameter \u53c2\u6570<\/th><th>RS Guidelines RS\u6307\u5357<\/th><th>RTS Guidelines RTS\u6307\u5357<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td class=\"param-name\">Min. Drum Diameter<span class=\"param-cn\">\u6700\u5c0f\u5377\u7b52\u76f4\u5f84<\/span><\/td><td>\u226512\u00d7 cable OD<\/td><td>\u226512\u00d7 cable OD<\/td><\/tr>\n<tr><td class=\"param-name\">Min. Installation Temp.<span class=\"param-cn\">\u6700\u4f4e\u5b89\u88c5\u6e29\u5ea6<\/span><\/td><td>-25\u00b0C<\/td><td>-25\u00b0C<\/td><\/tr>\n<tr><td class=\"param-name\">Operating Temp. Range<span class=\"param-cn\">\u5de5\u4f5c\u6e29\u5ea6\u8303\u56f4<\/span><\/td><td>-40\u00b0C to +90\u00b0C (fixed), -25\u00b0C to +90\u00b0C (flexed)<\/td><td>Same<\/td><\/tr>\n<tr><td class=\"param-name\">Reeling Tension<span class=\"param-cn\">\u5377\u7ed5\u5f20\u529b<\/span><\/td><td>Per DIN VDE 0298-3<\/td><td>Slightly reduced recommended<\/td><\/tr>\n<tr><td class=\"param-name\">Layer Overlap<span class=\"param-cn\">\u5c42\u95f4\u642d\u63a5<\/span><\/td><td>Standard winding pattern<\/td><td>Precise winding more critical<\/td><\/tr>\n<tr><td class=\"param-name\">Edge Clearance<span class=\"param-cn\">\u8fb9\u7f18\u95f4\u9699<\/span><\/td><td>\u22651.5\u00d7 cable OD from flange<\/td><td>\u22651.5\u00d7 cable OD from flange<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n\n<section>\n<h2>Available Variants with Fiber Optics <span class=\"cn\">\u5149\u7ea4\u96c6\u6210\u7248\u672c<\/span><\/h2>\n<p>Both RS and RTS versions are available with integrated optical fiber elements (OFE designation) for combined power and data transmission. In the RTS-OFE version, split protective earth cores are integrated in two of the three interstices, with the optical fiber element accommodated in the third interstice.<\/p>\n\n<table>\n<thead>\n<tr><th>Feature \u7279\u6027<\/th><th>Standard Power \u6807\u51c6\u7535\u529b\u578b<\/th><th>OFE (Fiber Optic) \u5149\u7ea4\u96c6\u6210\u578b<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td class=\"param-name\">Designation<span class=\"param-cn\">\u578b\u53f7\u6807\u8bc6<\/span><\/td><td>(N)TSCGEWTOEUS<\/td><td>(N)TSCGEWTOEUS OFE<\/td><\/tr>\n<tr><td class=\"param-name\">Fiber Options<span class=\"param-cn\">\u5149\u7ea4\u9009\u9879<\/span><\/td><td>\u2014<\/td><td>9\/125\u03bcm, 50\/125\u03bcm, 62.5\/125\u03bcm<\/td><\/tr>\n<tr><td class=\"param-name\">Fiber Count<span class=\"param-cn\">\u7ea4\u82af\u6570\u91cf<\/span><\/td><td>\u2014<\/td><td>6, 12, 18, or 24 fibers<\/td><\/tr>\n<tr><td class=\"param-name\">Additional Standard<span class=\"param-cn\">\u9644\u52a0\u6807\u51c6<\/span><\/td><td>\u2014<\/td><td>DIN VDE 0888<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n\n<section class=\"reference-section\">\n<h3>Technical References &#038; Standards \u6280\u672f\u53c2\u8003\u4e0e\u6807\u51c6<\/h3>\n<ol class=\"ref-list\">\n<li>German Institute for Standardization \u2014 DIN VDE 0250-813: Medium voltage trailing cables for rated voltages 3.6\/6 kV to 18\/30 kV. <a href=\"https:\/\/www.vde-verlag.de\/\" target=\"_blank\" rel=\"nofollow noopener\">www.vde-verlag.de<\/a><\/li>\n<li>Nexans Germany \u2014 RHEYFIRM\u00ae (RTS) R-(N)TSCGEWTOEUS Technical Documentation. <a href=\"https:\/\/www.nexans.de\/\" target=\"_blank\" rel=\"nofollow noopener\">www.nexans.de<\/a><\/li>\n<li>CSE Industrial Electrical Distributors \u2014 RHEYFIRM\u00ae(RTS) Cable Specifications. <a href=\"https:\/\/www.cse-distributors.co.uk\/\" target=\"_blank\" rel=\"nofollow noopener\">www.cse-distributors.co.uk<\/a><\/li>\n<li>DIN VDE 0298-3\/4: Use of cables and flexible cords in power installations. <a href=\"https:\/\/www.beuth.de\/\" target=\"_blank\" rel=\"nofollow noopener\">www.beuth.de<\/a><\/li>\n<li>Tratos Group \u2014 DIN VDE 0250 Part 813 Standard Information. <a href=\"https:\/\/tratosgroup.com\/products\/standards\/others\/din-vde-250-part-813\/\" target=\"_blank\" rel=\"nofollow noopener\">tratosgroup.com<\/a><\/li>\n<li>Prysmian Group \u2014 PROTOLON Medium Voltage Reeling Cables Technical Data. <a href=\"https:\/\/www.prysmian.com\/\" target=\"_blank\" rel=\"nofollow noopener\">www.prysmian.com<\/a><\/li>\n<li>Incore Cables \u2014 (N)TSCGEWOEU Cable Datasheet. <a href=\"https:\/\/www.incore-cables.com\/\" target=\"_blank\" rel=\"nofollow noopener\">www.incore-cables.com<\/a><\/li>\n<\/ol>\n<\/section>\n\n<section class=\"contact-section\">\n<h3>Contact Anhui Feichun Special Cable \u8054\u7cfb\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06<\/h3>\n<div class=\"contact-grid\">\n<div class=\"contact-item\">\n<strong>WhatsApp \u5fae\u4fe1\u540c\u53f7<\/strong>\n<a href=\"https:\/\/wa.me\/8613855123218\" target=\"_blank\" rel=\"nofollow noopener\">+86 138 5512 3218<\/a>\n<\/div>\n<div class=\"contact-item\">\n<strong>Technical Support \u6280\u672f\u652f\u6301<\/strong>\n<a href=\"mailto:tech@feichuncables.com\" rel=\"nofollow noopener\">tech@feichuncables.com<\/a>\n<\/div>\n<div class=\"contact-item\">\n<strong>Sales Inquiry \u9500\u552e\u54a8\u8be2<\/strong>\n<a href=\"mailto:zihao.yang@feichuncables.com\" rel=\"nofollow noopener\">zihao.yang@feichuncables.com<\/a>\n<\/div>\n<div class=\"contact-item\">\n<strong>Export Department \u51fa\u53e3\u90e8<\/strong>\n<a href=\"mailto:ziyu.huang@feichuncables.com\" rel=\"nofollow noopener\">ziyu.huang@feichuncables.com<\/a>\n<\/div>\n<\/div>\n<\/section>\n\n<div class=\"disclaimer\">\n<strong>Disclaimer \u514d\u8d23\u58f0\u660e:<\/strong> Technical specifications are provided for reference purposes only. Actual cable dimensions and performance may vary by specific configuration and manufacturer. Cable selection must be verified against current manufacturer datasheets and applicable DIN VDE standards. Consult qualified engineers for specific project requirements. \u6280\u672f\u89c4\u683c\u4ec5\u4f9b\u53c2\u8003\uff0c\u5b9e\u9645\u7535\u7f06\u5c3a\u5bf8\u548c\u6027\u80fd\u56e0\u5177\u4f53\u914d\u7f6e\u548c\u5236\u9020\u5546\u800c\u5f02\uff0c\u987b\u4ee5\u5382\u5bb6\u6700\u65b0\u6570\u636e\u8868\u548c\u9002\u7528DIN VDE\u6807\u51c6\u4e3a\u51c6\u3002\n<\/div>\n<\/article>\n\n<footer>\n<p>\u00a9 2025 Anhui Feichun Special Cable Co., Ltd. \u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8 | All Rights Reserved<\/p>\n<p>Professional manufacturer of reeling cables, crane cables, and special industrial cables<br>\u4e13\u4e1a\u751f\u4ea7\u5377\u7b52\u7535\u7f06\u3001\u8d77\u91cd\u673a\u7535\u7f06\u53ca\u7279\u79cd\u5de5\u4e1a\u7535\u7f06<\/p>\n<\/footer>\n<\/div>\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"RHEYFIRM\u00ae represents Nexans&#8217; premium brand of flexible medium voltage reeling cables designed for high and extreme mechanical stress applications. These cables are engineered especially for torsional stress and high reeling speeds, with capability for deflection into different planes. The choice between standard (RS) and reduced diameter (RTS) versions significantly impacts reel capacity, installation flexibility, and overall system performance in space-constrained environments.\nRHEYFIRM\u00ae\u662fNexans\u9488\u5bf9\u9ad8\u5f3a\u5ea6\u673a\u68b0\u5e94\u529b\u5e94\u7528\u8bbe\u8ba1\u7684\u4f18\u8d28\u67d4\u6027\u4e2d\u538b\u5377\u7b52\u7535\u7f06\u54c1\u724c\uff0c\u4e13\u4e3a\u626d\u8f6c\u5e94\u529b\u548c\u9ad8\u901f\u5377\u7ed5\u5de5\u51b5\u8bbe\u8ba1\u3002\u6807\u51c6\u578b(RS)\u4e0e\u51cf\u5f84\u578b(RTS)\u7684\u9009\u62e9\u5bf9\u5377\u7b52\u5bb9\u91cf\u548c\u7cfb\u7edf\u6027\u80fd\u6709\u91cd\u8981\u5f71\u54cd\u3002","protected":false},"author":1,"featured_media":6569,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[222,66,8,56],"tags":[41781,41785,39122,41789,5182,41787,41792,41793,41786,41783,41788,41790,171,41780,41773,41777,107,176,214,41794,41791,41779,41776,41774,41782,41775,1942,41778,41784],"class_list":["post-6568","post","type-post","status-publish","format-standard","has-post-thumbnail","category-as-nzs-1802-reeling-cables-for-underground-mining","category-common-problems-encountered-in-cable-applications","category-cranes-and-material-handling-cable","category-reeling-cable","tag-50c-cable-rating","tag-60c-mining-cable","tag-alaska-mining-cable","tag-arctic-grade-cable-bs6004","tag-arctic-mining-cable","tag-canada-arctic-mining-cable","tag-cold-bend-rating-cable","tag-cold-climate-mining-cable","tag-cold-impact-rating-cable","tag-cold-temperature-rating-cable","tag-cpe-jacket-standard-cable","tag-epr-insulation-cold-weather","tag-explosion-proof-mining-cable","tag-extreme-cold-weather-cable","tag-extreme-mining-cable-specifications","tag-greenland-mining-operations-cable","tag-heavy-duty-e-loader-mining-cable","tag-icea-s-75-381-2","tag-mining-power-cable","tag-northern-mining-cable-solutions","tag-pur-polyurethane-cable-cold-resistant","tag-scandinavia-mining-cable","tag-siberia-mining-cable-specifications","tag-standard-rs-mining-cable","tag-subarctic-mining-operations-cable","tag-surface-mining-cold-weather-cable","tag-tpu-jacket-mining-cable","tag-underground-arctic-mining-cable","tag-xlpe-insulation-arctic-cable","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/6568","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=6568"}],"version-history":[{"count":1,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/6568\/revisions"}],"predecessor-version":[{"id":6570,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/6568\/revisions\/6570"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/6569"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=6568"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=6568"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=6568"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}