{"id":6083,"date":"2026-02-05T11:39:10","date_gmt":"2026-02-05T03:39:10","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=6083"},"modified":"2026-02-05T11:41:11","modified_gmt":"2026-02-05T03:41:11","slug":"protolonsb-shd-gc-i-5-15-kv","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/protolonsb-shd-gc-i-5-15-kv\/","title":{"rendered":"PROTOLON(SB) SHD-GC I 5 &#8211; 15 KV"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>Shielded Heavy-Duty Ground Check Cables (SHD-GC)<\/strong>\u00a0are specialized power supply and connection cables designed for large material handling equipment such as excavators in opencast mining operations. These cables withstand extremely high mechanical stresses and are particularly suitable for trailing operations where abrasion and chafing stresses are expected.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-dominant-color=\"b3b3b2\" data-has-transparency=\"true\" style=\"--dominant-color: #b3b3b2;\" loading=\"lazy\" decoding=\"async\" width=\"288\" height=\"628\" sizes=\"auto, (max-width: 288px) 100vw, 288px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/\u5fae\u4fe1\u56fe\u7247_20260204102558_583_34-288x628.avif\" alt=\"\" class=\"wp-image-6084 has-transparency\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/\u5fae\u4fe1\u56fe\u7247_20260204102558_583_34-288x628.avif 288w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/\u5fae\u4fe1\u56fe\u7247_20260204102558_583_34-138x300.avif 138w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/\u5fae\u4fe1\u56fe\u7247_20260204102558_583_34.avif 349w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n    <meta charset=\"UTF-8\">\n    <meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n    <title>PROTOLON(SB) SHD-GC I 5-15 KV | Anhui Feichun Special Cable Co., Ltd.<\/title>\n    <style>\n        :root {\n            --bg-primary: #ffffff;\n            --bg-secondary: #f5f5f5;\n            --text-primary: #1a1a1a;\n            --text-secondary: #4a4a4a;\n            --border-color: #d0d0d0;\n            --accent-color: #2c5282;\n            --table-header-bg: #e8e8e8;\n            --table-row-hover: #f0f0f0;\n        }\n\n        @media (prefers-color-scheme: dark) {\n            :root {\n                --bg-primary: #1a1a1a;\n                --bg-secondary: #2d2d2d;\n                --text-primary: #e8e8e8;\n                --text-secondary: #b8b8b8;\n                --border-color: #404040;\n                --accent-color: #4a90e2;\n                --table-header-bg: #333333;\n                --table-row-hover: #383838;\n            }\n        }\n\n        * {\n            margin: 0;\n            padding: 0;\n            box-sizing: border-box;\n        }\n\n        body {\n            font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Arial, sans-serif;\n            line-height: 1.6;\n            color: var(--text-primary);\n            background-color: var(--bg-primary);\n            max-width: 100%;\n            overflow-x: hidden;\n        }\n\n        .container {\n            max-width: 1400px;\n            margin: 0 auto;\n            padding: 20px;\n        }\n\n        header {\n            background-color: var(--bg-secondary);\n            border-bottom: 2px solid var(--border-color);\n            padding: 30px 0;\n            margin-bottom: 40px;\n        }\n\n        .header-content {\n            max-width: 1400px;\n            margin: 0 auto;\n            padding: 0 20px;\n        }\n\n        h1 {\n            font-size: 2em;\n            font-weight: 700;\n            color: var(--accent-color);\n            margin-bottom: 10px;\n        }\n\n        .company-name {\n            font-size: 1.1em;\n            color: var(--text-secondary);\n            font-weight: 500;\n        }\n\n        .company-name-cn {\n            font-size: 0.95em;\n            color: var(--text-secondary);\n            margin-top: 5px;\n        }\n\n        h2 {\n            font-size: 1.5em;\n            color: var(--accent-color);\n            margin: 30px 0 15px 0;\n            font-weight: 600;\n            border-bottom: 2px solid var(--border-color);\n            padding-bottom: 8px;\n        }\n\n        h3 {\n            font-size: 1.2em;\n            color: var(--text-primary);\n            margin: 25px 0 12px 0;\n            font-weight: 600;\n        }\n\n        p {\n            margin-bottom: 15px;\n            color: var(--text-primary);\n        }\n\n        .product-intro {\n            background-color: var(--bg-secondary);\n            padding: 25px;\n            border-left: 4px solid var(--accent-color);\n            margin-bottom: 30px;\n        }\n\n        .bilingual {\n            margin-bottom: 8px;\n        }\n\n        .cn-text {\n            color: var(--text-secondary);\n            font-size: 0.92em;\n            margin-top: 5px;\n        }\n\n        table {\n            width: 100%;\n            border-collapse: collapse;\n            margin: 20px 0;\n            background-color: var(--bg-primary);\n            border: 1px solid var(--border-color);\n        }\n\n        th {\n            background-color: var(--table-header-bg);\n            color: var(--text-primary);\n            font-weight: 600;\n            padding: 12px 15px;\n            text-align: left;\n            border: 1px solid var(--border-color);\n            font-size: 0.95em;\n        }\n\n        td {\n            padding: 10px 15px;\n            border: 1px solid var(--border-color);\n            color: var(--text-primary);\n        }\n\n        tr:hover {\n            background-color: var(--table-row-hover);\n        }\n\n        .standards-list {\n            background-color: var(--bg-secondary);\n            padding: 20px;\n            margin: 20px 0;\n        }\n\n        .standards-list ul {\n            list-style: none;\n            padding-left: 0;\n        }\n\n        .standards-list li {\n            padding: 8px 0;\n            border-bottom: 1px solid var(--border-color);\n        }\n\n        .standards-list li:last-child {\n            border-bottom: none;\n        }\n\n        .citation {\n            font-size: 0.85em;\n            color: var(--text-secondary);\n            margin-top: 5px;\n        }\n\n        .contact-section {\n            background-color: var(--bg-secondary);\n            padding: 25px;\n            margin-top: 40px;\n            border-radius: 4px;\n        }\n\n        .contact-info {\n            display: grid;\n            grid-template-columns: repeat(auto-fit, minmax(250px, 1fr));\n            gap: 15px;\n            margin-top: 15px;\n        }\n\n        .contact-item {\n            padding: 10px;\n        }\n\n        .contact-item strong {\n            display: block;\n            margin-bottom: 5px;\n            color: var(--accent-color);\n        }\n\n        a {\n            color: var(--accent-color);\n            text-decoration: none;\n        }\n\n        a:hover {\n            text-decoration: underline;\n        }\n\n        .construction-section {\n            margin: 30px 0;\n        }\n\n        .construction-list {\n            background-color: var(--bg-secondary);\n            padding: 20px;\n            border-left: 3px solid var(--accent-color);\n        }\n\n        .construction-list ol {\n            padding-left: 20px;\n        }\n\n        .construction-list li {\n            margin: 8px 0;\n            line-height: 1.7;\n        }\n\n        @media (max-width: 768px) {\n            h1 {\n                font-size: 1.5em;\n            }\n\n            h2 {\n                font-size: 1.3em;\n            }\n\n            .container {\n                padding: 15px;\n            }\n\n            table {\n                font-size: 0.9em;\n            }\n\n            th, td {\n                padding: 8px 10px;\n            }\n        }\n    <\/style>\n<\/head>\n<body>\n    <header>\n        <div class=\"header-content\">\n            <h1>PROTOLON(SB) SHD-GC I 5 &#8211; 15 KV<\/h1>\n            <div class=\"company-name\">Anhui Feichun Special Cable Co., Ltd.<\/div>\n            <div class=\"company-name-cn\">\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/div>\n        <\/div>\n    <\/header>\n\n    <div class=\"container\">\n        <section class=\"product-intro\">\n            <p class=\"bilingual\">\n                <strong>Shielded Heavy-Duty Ground Check Cables (SHD-GC)<\/strong> are specialized power supply and connection cables designed for large material handling equipment such as excavators in opencast mining operations. These cables withstand extremely high mechanical stresses and are particularly suitable for trailing operations where abrasion and chafing stresses are expected.\n            <\/p>\n            <p class=\"cn-text\">\n                <strong>\u5c4f\u853d\u91cd\u578b\u63a5\u5730\u68c0\u6d4b\u7535\u7f06 (SHD-GC)<\/strong> \u662f\u4e13\u4e3a\u5927\u578b\u7269\u6599\u642c\u8fd0\u8bbe\u5907\uff08\u5982\u9732\u5929\u77ff\u5c71\u6316\u6398\u673a\uff09\u8bbe\u8ba1\u7684\u4f9b\u7535\u548c\u8fde\u63a5\u7535\u7f06\uff0c\u53ef\u627f\u53d7\u6781\u9ad8\u7684\u673a\u68b0\u5e94\u529b\uff0c\u7279\u522b\u9002\u7528\u4e8e\u9884\u671f\u78e8\u635f\u548c\u64e6\u4f24\u5e94\u529b\u7684\u62d6\u66f3\u4f5c\u4e1a\u3002\n            <\/p>\n        <\/section>\n\n        <h2>Standards &#038; Approvals (\u6807\u51c6\u4e0e\u8ba4\u8bc1)<\/h2>\n        <div class=\"standards-list\">\n            <ul>\n                <li>\n                    <strong>ANSI\/NEMA WC 58 \/ ICEA S-75-381<\/strong> &#8211; Portable and Power Feeder Cables for Use in Mines and Similar Applications\n                    <div class=\"citation\">Reference: <a href=\"https:\/\/webstore.ansi.org\/standards\/nema\/ansinemawc58icea753812017\" rel=\"nofollow noopener\" target=\"_blank\">ANSI Standards Store<\/a><\/div>\n                <\/li>\n                <li>\n                    <strong>DIN VDE 0298-3<\/strong> &#8211; Application of cables and cords in power installations (General mechanical parameters)\n                    <div class=\"citation\">Reference: <a href=\"https:\/\/www.dinmedia.de\/en\/standard\/din-vde-0298-3\/88069819\" rel=\"nofollow noopener\" target=\"_blank\">DIN Media<\/a><\/div>\n                <\/li>\n                <li>\n                    <strong>DIN EN 60332-1-2 \/ IEC 60332-1-2<\/strong> &#8211; Fire performance testing (Vertical flame propagation test)\n                    <div class=\"citation\">Reference: <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/1475\" rel=\"nofollow noopener\" target=\"_blank\">IEC Webstore<\/a><\/div>\n                <\/li>\n                <li>\n                    <strong>IEC 60811-404<\/strong> &#8211; Chemical behaviour testing standards\n                <\/li>\n                <li>\n                    <strong>EN 50525-2-21<\/strong> &#8211; Electrical parameters compliance\n                <\/li>\n            <\/ul>\n        <\/div>\n\n        <h2>Technical Parameters (\u6280\u672f\u53c2\u6570)<\/h2>\n\n        <h3>Thermal Parameters (\u70ed\u53c2\u6570)<\/h3>\n        <table>\n            <tr>\n                <th>Parameter (\u53c2\u6570)<\/th>\n                <th>Value (\u6570\u503c)<\/th>\n            <\/tr>\n            <tr>\n                <td>Max. Conductor Temperature (\u6700\u9ad8\u5bfc\u4f53\u6e29\u5ea6)<\/td>\n                <td>90 \u00b0C<\/td>\n            <\/tr>\n            <tr>\n                <td>Max. Conductor Temperature at Short Circuit (\u77ed\u8def\u65f6\u6700\u9ad8\u5bfc\u4f53\u6e29\u5ea6)<\/td>\n                <td>250 \u00b0C<\/td>\n            <\/tr>\n            <tr>\n                <td>Ambient Temperature &#8211; Fixed Installation Min. (\u56fa\u5b9a\u5b89\u88c5\u6700\u4f4e\u73af\u5883\u6e29\u5ea6)<\/td>\n                <td>-40 \u00b0C<\/td>\n            <\/tr>\n            <tr>\n                <td>Ambient Temperature &#8211; Fixed Installation Max. (\u56fa\u5b9a\u5b89\u88c5\u6700\u9ad8\u73af\u5883\u6e29\u5ea6)<\/td>\n                <td>80 \u00b0C<\/td>\n            <\/tr>\n            <tr>\n                <td>Ambient Temperature &#8211; Flexible Installation Min. (\u67d4\u6027\u5b89\u88c5\u6700\u4f4e\u73af\u5883\u6e29\u5ea6)<\/td>\n                <td>-30 \u00b0C<\/td>\n            <\/tr>\n            <tr>\n                <td>Ambient Temperature &#8211; Flexible Installation Max. (\u67d4\u6027\u5b89\u88c5\u6700\u9ad8\u73af\u5883\u6e29\u5ea6)<\/td>\n                <td>60 \u00b0C<\/td>\n            <\/tr>\n        <\/table>\n\n        <h3>Chemical Parameters (\u5316\u5b66\u53c2\u6570)<\/h3>\n        <table>\n            <tr>\n                <th>Property (\u6027\u80fd)<\/th>\n                <th>Specification (\u89c4\u683c)<\/th>\n            <\/tr>\n            <tr>\n                <td>Flame Retardant (\u963b\u71c3\u6027)<\/td>\n                <td>EN\/IEC 60332-1-2 Compliant<\/td>\n            <\/tr>\n            <tr>\n                <td>Oil Resistance (\u8010\u6cb9\u6027)<\/td>\n                <td>Yes (\u662f)<\/td>\n            <\/tr>\n            <tr>\n                <td>Ozone Resistance (\u8010\u81ed\u6c27\u6027)<\/td>\n                <td>Yes (\u662f)<\/td>\n            <\/tr>\n            <tr>\n                <td>UV Resistance (\u8010\u7d2b\u5916\u7ebf\u6027)<\/td>\n                <td>Yes (\u662f)<\/td>\n            <\/tr>\n        <\/table>\n\n        <h3>Mechanical Parameters (\u673a\u68b0\u53c2\u6570)<\/h3>\n        <table>\n            <tr>\n                <th>Parameter (\u53c2\u6570)<\/th>\n                <th>Value (\u6570\u503c)<\/th>\n            <\/tr>\n            <tr>\n                <td>Torsional Stress (\u626d\u8f6c\u5e94\u529b)<\/td>\n                <td>+\/- 25 \u00b0\/m<\/td>\n            <\/tr>\n            <tr>\n                <td>Permanent Tensile Strength (Rule) (\u6c38\u4e45\u62c9\u4f38\u5f3a\u5ea6)<\/td>\n                <td>20 N\/mm\u00b2 static<\/td>\n            <\/tr>\n            <tr>\n                <td>Bending Radius &#8211; Fixed Installation (\u5f2f\u66f2\u534a\u5f84-\u56fa\u5b9a\u5b89\u88c5)<\/td>\n                <td>6 x D (acc. to VDE 0298-3)<\/td>\n            <\/tr>\n            <tr>\n                <td>Bending Radius &#8211; Flexible Operation (\u5f2f\u66f2\u534a\u5f84-\u67d4\u6027\u64cd\u4f5c)<\/td>\n                <td>10 x D<\/td>\n            <\/tr>\n        <\/table>\n        <div class=\"citation\">Bending radius specifications according to DIN VDE 0298-3 standards for cable installations. Reference: <a href=\"https:\/\/www.dinmedia.de\/en\/standard\/din-vde-0298-3\/88069819\" rel=\"nofollow noopener\" target=\"_blank\">DIN VDE 0298-3<\/a><\/div>\n\n        <h3>Electrical Parameters (\u7535\u6c14\u53c2\u6570)<\/h3>\n        <table>\n            <tr>\n                <th>Voltage Rating (\u7535\u538b\u7b49\u7ea7)<\/th>\n                <th>Rated Voltage U0\/U (Um) (\u989d\u5b9a\u7535\u538b)<\/th>\n                <th>Test Voltage (\u6d4b\u8bd5\u7535\u538b)<\/th>\n                <th>Nominal Voltage U (\u6807\u79f0\u7535\u538b)<\/th>\n            <\/tr>\n            <tr>\n                <td>5 kV<\/td>\n                <td>5 kV<\/td>\n                <td>14 kV<\/td>\n                <td>5,000 V<\/td>\n            <\/tr>\n            <tr>\n                <td>8 kV<\/td>\n                <td>8 kV<\/td>\n                <td>23 kV<\/td>\n                <td>8,000 V<\/td>\n            <\/tr>\n            <tr>\n                <td>15 kV<\/td>\n                <td>15 kV<\/td>\n                <td>43 kV<\/td>\n                <td>15,000 V<\/td>\n            <\/tr>\n        <\/table>\n\n        <h2>Cable Construction (\u7535\u7f06\u7ed3\u6784)<\/h2>\n        <div class=\"construction-section\">\n            <div class=\"construction-list\">\n                <ol>\n                    <li><strong>Conductor (\u5bfc\u4f53):<\/strong> Finely stranded copper, tinned \/ \u7cbe\u7ec6\u7ede\u5408\u9540\u9521\u94dc<\/li>\n                    <li><strong>Ground-Check (\u63a5\u5730\u68c0\u6d4b):<\/strong> Finely stranded copper, tinned, with yellow rubber insulation \/ \u7cbe\u7ec6\u7ede\u5408\u9540\u9521\u94dc\uff0c\u5e26\u9ec4\u8272\u6a61\u80f6\u7edd\u7f18<\/li>\n                    <li><strong>Ground (\u63a5\u5730):<\/strong> Finely stranded copper, tinned \/ \u7cbe\u7ec6\u7ede\u5408\u9540\u9521\u94dc<\/li>\n                    <li><strong>Inner Semi-conducting Layer (\u5185\u534a\u5bfc\u7535\u5c42):<\/strong> Semi-conductive EPR \/ \u534a\u5bfc\u7535EPR<\/li>\n                    <li><strong>Core Insulation (\u82af\u7ebf\u7edd\u7f18):<\/strong> EPR rubber PROTOLON \/ EPR\u6a61\u80f6PROTOLON<\/li>\n                    <li><strong>Outer Semi-conducting Layer (\u5916\u534a\u5bfc\u7535\u5c42):<\/strong> Semi-conductive NBR easy strip \/ \u534a\u5bfc\u7535NBR\u6613\u5265\u79bb<\/li>\n                    <li><strong>Core Arrangement (\u82af\u7ebf\u6392\u5217):<\/strong> Three main conductors with individual concentric mix screen of tinned copper and colored polyester yarn, laid up with 2 ground conductors and one GC in the outer interstices. Tear-resistant reinforcing tape over assembly \/ \u4e09\u6839\u4e3b\u5bfc\u4f53\uff0c\u6bcf\u6839\u914d\u6709\u9540\u9521\u94dc\u548c\u5f69\u8272\u805a\u916f\u4e1d\u540c\u5fc3\u6df7\u5408\u5c4f\u853d\uff0c\u4e0e2\u6839\u63a5\u5730\u5bfc\u4f53\u548c1\u6839GC\u7ebf\u7f06\u7ede\u5408\u5728\u5916\u90e8\u95f4\u9699\u4e2d\uff0c\u7ec4\u4ef6\u4e0a\u8986\u76d6\u6297\u6495\u88c2\u52a0\u5f3a\u5e26<\/li>\n                    <li><strong>Inner Sheath (\u5185\u62a4\u5957):<\/strong> Rubber &#8211; polychloroprene (PCP) \/ \u6a61\u80f6-\u6c2f\u4e01\u6a61\u80f6<\/li>\n                    <li><strong>Armoring\/Reinforcement (\u94e0\u88c5\/\u52a0\u5f3a):<\/strong> Polyester Mesh tape \/ \u805a\u916f\u7f51\u72b6\u5e26<\/li>\n                    <li><strong>Outer Sheath (\u5916\u62a4\u5957):<\/strong> Rubber &#8211; polychloroprene (PCP) \/ \u6a61\u80f6-\u6c2f\u4e01\u6a61\u80f6<\/li>\n                <\/ol>\n            <\/div>\n        <\/div>\n\n        <h2>Applications (\u5e94\u7528\u573a\u666f)<\/h2>\n        <p class=\"bilingual\">\n            These cables are specifically designed for use as power supply or connection cables for large material handling machines operating in extremely harsh environments. Primary applications include excavators and draglines in opencast mining operations where cables are subject to severe mechanical stress, including abrasion, chafing, torsion, and dynamic tensile loads during trailing operations.\n        <\/p>\n        <p class=\"cn-text\">\n            \u8fd9\u4e9b\u7535\u7f06\u4e13\u4e3a\u5728\u6781\u7aef\u6076\u52a3\u73af\u5883\u4e2d\u8fd0\u884c\u7684\u5927\u578b\u7269\u6599\u642c\u8fd0\u673a\u68b0\u7684\u4f9b\u7535\u6216\u8fde\u63a5\u7535\u7f06\u800c\u8bbe\u8ba1\u3002\u4e3b\u8981\u5e94\u7528\u5305\u62ec\u9732\u5929\u91c7\u77ff\u4f5c\u4e1a\u4e2d\u7684\u6316\u6398\u673a\u548c\u62c9\u94f2\uff0c\u5728\u8fd9\u4e9b\u4f5c\u4e1a\u4e2d\uff0c\u7535\u7f06\u5728\u62d6\u66f3\u64cd\u4f5c\u671f\u95f4\u627f\u53d7\u4e25\u91cd\u7684\u673a\u68b0\u5e94\u529b\uff0c\u5305\u62ec\u78e8\u635f\u3001\u64e6\u4f24\u3001\u626d\u8f6c\u548c\u52a8\u6001\u62c9\u4f38\u8d1f\u8f7d\u3002\n        <\/p>\n        <div class=\"citation\">Application specifications based on ANSI\/NEMA WC 58 standards for mining cable applications. Reference: <a href=\"https:\/\/standards.globalspec.com\/std\/10287211\/ANSI\/NEMA%20WC%2058\" rel=\"nofollow noopener\" target=\"_blank\">Global Standards<\/a><\/div>\n\n        <h2>Quality Certifications (\u8d28\u91cf\u8ba4\u8bc1)<\/h2>\n        <p>\n            The PROTOLON(SB) SHD-GC I cable series meets international standards for mining and heavy-duty industrial applications. The flame retardant properties comply with IEC 60332-1-2, which specifies testing procedures for vertical flame propagation resistance under fire conditions. This certification ensures the cable can self-extinguish and minimize fire damage in critical installations.\n        <\/p>\n        <p class=\"cn-text\">\n            PROTOLON(SB) SHD-GC I\u7cfb\u5217\u7535\u7f06\u7b26\u5408\u91c7\u77ff\u548c\u91cd\u578b\u5de5\u4e1a\u5e94\u7528\u7684\u56fd\u9645\u6807\u51c6\u3002\u963b\u71c3\u6027\u80fd\u7b26\u5408IEC 60332-1-2\u6807\u51c6\uff0c\u8be5\u6807\u51c6\u89c4\u5b9a\u4e86\u5728\u706b\u707e\u6761\u4ef6\u4e0b\u5782\u76f4\u706b\u7130\u4f20\u64ad\u963b\u529b\u7684\u6d4b\u8bd5\u7a0b\u5e8f\u3002\u6b64\u8ba4\u8bc1\u786e\u4fdd\u7535\u7f06\u53ef\u4ee5\u81ea\u7184\u5e76\u6700\u5927\u7a0b\u5ea6\u5730\u51cf\u5c11\u5173\u952e\u5b89\u88c5\u4e2d\u7684\u706b\u707e\u635f\u5bb3\u3002\n        <\/p>\n        <div class=\"citation\">Fire performance standards reference: <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/1475\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60332-1-2:2004<\/a><\/div>\n\n        <div class=\"contact-section\">\n            <h2>Contact Information (\u8054\u7cfb\u65b9\u5f0f)<\/h2>\n            <div class=\"contact-info\">\n                <div class=\"contact-item\">\n                    <strong>WhatsApp<\/strong>\n                    <a href=\"https:\/\/wa.me\/8613855123218\" rel=\"nofollow noopener\" target=\"_blank\">+86 13855 123218<\/a>\n                <\/div>\n                <div class=\"contact-item\">\n                    <strong>Technical Support (\u6280\u672f\u652f\u6301)<\/strong>\n                    <a href=\"mailto:tech@feichuncables.com\" rel=\"nofollow\">tech@feichuncables.com<\/a>\n                <\/div>\n                <div class=\"contact-item\">\n                    <strong>Sales Contact (\u9500\u552e\u8054\u7cfb)<\/strong>\n                    <a href=\"mailto:zihao.yang@feichuncables.com\" rel=\"nofollow\">zihao.yang@feichuncables.com<\/a>\n                <\/div>\n                <div class=\"contact-item\">\n                    <strong>Engineering Contact (\u5de5\u7a0b\u8054\u7cfb)<\/strong>\n                    <a href=\"mailto:ziyu.huang@feichuncables.com\" rel=\"nofollow\">ziyu.huang@feichuncables.com<\/a>\n                <\/div>\n            <\/div>\n        <\/div>\n    <\/div>\n<\/body>\n<\/html>\n\n\n\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/PROTOLONSB-SHD-GC-_-5-15-KV-Technical-Specification-1.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"\u5d4c\u5165 PROTOLON(SB) SHD-GC _ 5-15 KV - Technical Specification\"><\/object><a id=\"wp-block-file--media-cffbfff4-f846-44cf-8476-11d8be8709b3\" href=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/PROTOLONSB-SHD-GC-_-5-15-KV-Technical-Specification-1.pdf\">PROTOLON(SB) SHD-GC _ 5-15 KV &#8211; Technical Specification<\/a><a href=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/PROTOLONSB-SHD-GC-_-5-15-KV-Technical-Specification-1.pdf\" class=\"wp-block-file__button wp-element-button\" aria-describedby=\"wp-block-file--media-cffbfff4-f846-44cf-8476-11d8be8709b3\" download>\u4e0b\u8f7d<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"Shielded Heavy-Duty Ground Check Cables (SHD-GC) are specialized power supply and connection cables designed for large material handling equipment such as excavators in opencast mining operations. These cables withstand extremely high mechanical stresses and are particularly suitable for trailing operations where abrasion and chafing stresses are expected.","protected":false},"author":1,"featured_media":5383,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[66,209,56],"tags":[39598,39626,39608,39635,12058,39633,39624,39585,39610,7643,5738,2484,39599,39565,39609,39594,12154,1079,39614,444,820,39589,1499,171,39616,637,39596,5005,152,107,39597,176,11870,39615,828,111,2029,139,214,204,39632,39620,4513,1082,12879,39613,3974,39591,39588,39582,39580,39603,39625,12796,39618,8820,39581,39617,39622,13124,31668,22791,39586,39584,39629,39606,39595,32838,39631,10130,39583,39341,39592,39630,39636,37383,27264,39587,39602,36567,39179,39604,39612,39611,39601,39628,39634,39621,39590,39623,39605,39600,39627,32451,39607,39593,32308,39619],"class_list":["post-6083","post","type-post","status-publish","format-standard","has-post-thumbnail","category-common-problems-encountered-in-cable-applications","category-icea-s-75-381-portable-power-cables","category-reeling-cable","tag-30c-flexible-installation","tag-14-kv","tag-15-kv-voltage-rating","tag-23-kv","tag-250c-short-circuit-rating","tag-43-kv-test-voltage","tag-5-kv","tag-5-15-kv-cable","tag-8-kv","tag-90c-conductor-temperature","tag-abrasion-resistant","tag-anhui-feichun-special-cable","tag-ansi-nema-wc-58-compliant","tag-bending-radius-10d","tag-chafing-resistant","tag-concentric-copper-screen","tag-din-vde-0298-3","tag-dragline-cable","tag-dynamic-tensile-load","tag-en-50525-2-21","tag-epr-insulated-cable","tag-epr","tag-excavator-power-cable","tag-explosion-proof-mining-cable","tag-finely-stranded-tinned-copper-conductor","tag-fire-performance","tag-flame-retardant-iec-60332-1-2","tag-ground-check-conductor","tag-heavy-duty-mining-cable","tag-heavy-duty-e-loader-mining-cable","tag-heavy-duty-trailing-cable-2","tag-icea-s-75-381-2","tag-iec-60811-404","tag-large-material-handling-machines","tag-medium-voltage-mining-cable","tag-mining-cable","tag-mining-cable-supplier","tag-mining-cables","tag-mining-power-cable","tag-mining-trailing-cable","tag-nbr-easy-strip-layer-2","tag-nbr","tag-oil-resistant","tag-opencast-mining-cable","tag-ozone-resistant","tag-permanent-tensile-strength-20-n-mm","tag-polychloroprene-sheathed-cable","tag-polyester-mesh-reinforcement","tag-portable-feeder-cable","tag-protolonsb-cable","tag-protolonsb-shd-gc-i-5-15-kv","tag-quality-certifications","tag-rubber-polychloroprene-sheath","tag-semi-conductive-epr-layer","tag-severe-mechanical-stress","tag-shd-gc-cable","tag-shielded-heavy-duty-ground-check-cables","tag-tear-resistant-reinforcing-tape","tag-torsional-stress-25-m","tag-uv-resistant","tag-vertical-flame-propagation-test","tag-22791","tag-39586","tag-39584","tag-39629","tag-39595","tag-32838","tag-39631","tag-10130","tag-39583","tag-39341","tag-39592","tag-39630","tag-39636","tag-37383","tag-27264","tag-39587","tag-39602","tag-36567","tag-39179","tag-39604","tag-39612","tag-39611","tag-39601","tag-39628","tag-39634","tag-39621","tag-39590","tag-39623","tag-39605","tag-39600","tag-39627","tag-32451","tag-39607","tag-39593","tag-32308","tag-39619","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/6083","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=6083"}],"version-history":[{"count":3,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/6083\/revisions"}],"predecessor-version":[{"id":6090,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/6083\/revisions\/6090"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/5383"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=6083"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=6083"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=6083"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}