{"id":6070,"date":"2026-02-05T10:54:35","date_gmt":"2026-02-05T02:54:35","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=6070"},"modified":"2026-02-05T10:54:39","modified_gmt":"2026-02-05T02:54:39","slug":"trommelflex-m-pur-braided-d2x11y-1-kv","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/trommelflex-m-pur-braided-d2x11y-1-kv\/","title":{"rendered":"TROMMELFLEX-M-PUR BRAIDED D2X11Y 1 KV"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Flexible Low Voltage Reeling Cable with Halogen-Free Polyurethane Sheath<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">TROMMELFLEX-M-PUR\u67d4\u6027\u4f4e\u538b\u5377\u7b52\u7535\u7f06 \u00b7 \u65e0\u5364\u805a\u6c28\u916f\u62a4\u5957 \u00b7 \u5730\u4e0b\u91c7\u77ff\u4e13\u7528<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img data-dominant-color=\"dbd9a8\" data-has-transparency=\"true\" loading=\"lazy\" decoding=\"async\" width=\"258\" height=\"628\" sizes=\"auto, (max-width: 258px) 100vw, 258px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/\u5fae\u4fe1\u56fe\u7247_20260204100947_577_34-258x628.avif\" alt=\"\" class=\"wp-image-6071 has-transparency\" style=\"--dominant-color: #dbd9a8; width:347px;height:auto\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/\u5fae\u4fe1\u56fe\u7247_20260204100947_577_34-258x628.avif 258w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/\u5fae\u4fe1\u56fe\u7247_20260204100947_577_34-123x300.avif 123w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/\u5fae\u4fe1\u56fe\u7247_20260204100947_577_34.avif 316w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n    <meta charset=\"UTF-8\">\n    <meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n    <meta name=\"description\" content=\"TROMMELFLEX-M-PUR BRAIDED D2X11Y 1 KV - Flexible low voltage reeling cable with halogen-free polyurethane sheath for underground mining equipment - Anhui Feichun Special Cable Co., Ltd\">\n    <meta name=\"keywords\" content=\"TROMMELFLEX PUR, underground mining cable, halogen-free cable, LHD loader cable, drilling machine cable, PUR sheathed cable, D2X11Y cable, tunneling cable, scoop cable\">\n    <title>TROMMELFLEX-M-PUR D2X11Y 1 KV Underground Mining Cable | Anhui Feichun<\/title>\n    <style>\n        * {\n            margin: 0;\n            padding: 0;\n            box-sizing: border-box;\n        }\n\n        :root {\n            --bg-primary: #ffffff;\n            --bg-secondary: #f8f9fa;\n            --text-primary: #212529;\n            --text-secondary: #6c757d;\n            --border-color: #dee2e6;\n            --table-header: #343a40;\n            --table-hover: #f1f3f5;\n            --accent-color: #c41e3a;\n            --highlight-color: #28a745;\n            --link-color: #0066cc;\n        }\n\n        @media (prefers-color-scheme: dark) {\n            :root {\n                --bg-primary: #1a1a1a;\n                --bg-secondary: #2d2d2d;\n                --text-primary: #e9ecef;\n                --text-secondary: #adb5bd;\n                --border-color: #495057;\n                --table-header: #495057;\n                --table-hover: #343a40;\n                --accent-color: #dc3545;\n                --highlight-color: #4caf50;\n                --link-color: #4dabf7;\n            }\n        }\n\n        body {\n            font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, 'Helvetica Neue', Arial, sans-serif;\n            line-height: 1.6;\n            color: var(--text-primary);\n            background-color: var(--bg-primary);\n            transition: background-color 0.3s ease, color 0.3s ease;\n        }\n\n        .container {\n            max-width: 1400px;\n            margin: 0 auto;\n            padding: 20px;\n        }\n\n        header {\n            background: linear-gradient(135deg, var(--bg-secondary) 0%, var(--bg-primary) 100%);\n            padding: 40px 0;\n            border-bottom: 3px solid var(--accent-color);\n            margin-bottom: 40px;\n        }\n\n        .header-content {\n            max-width: 1400px;\n            margin: 0 auto;\n            padding: 0 20px;\n        }\n\n        h1 {\n            font-size: 2.4em;\n            font-weight: 700;\n            margin-bottom: 10px;\n            color: var(--text-primary);\n            letter-spacing: -0.5px;\n        }\n\n        .subtitle {\n            font-size: 1.2em;\n            color: var(--highlight-color);\n            margin-top: 10px;\n            font-weight: 600;\n        }\n\n        .chinese-title {\n            font-size: 0.9em;\n            color: var(--text-secondary);\n            margin-top: 8px;\n            font-weight: 400;\n        }\n\n        .company-info {\n            margin-top: 15px;\n            font-size: 1.1em;\n            color: var(--text-secondary);\n        }\n\n        .section {\n            margin: 50px 0;\n        }\n\n        h2 {\n            font-size: 1.8em;\n            font-weight: 700;\n            color: var(--accent-color);\n            margin-bottom: 20px;\n            padding-bottom: 10px;\n            border-bottom: 2px solid var(--border-color);\n        }\n\n        h3 {\n            font-size: 1.3em;\n            font-weight: 600;\n            color: var(--text-primary);\n            margin: 25px 0 15px 0;\n        }\n\n        p {\n            margin-bottom: 15px;\n            text-align: justify;\n        }\n\n        .intro-text {\n            font-size: 1.05em;\n            line-height: 1.8;\n            margin-bottom: 20px;\n        }\n\n        .highlight-box {\n            background-color: var(--bg-secondary);\n            border-left: 4px solid var(--highlight-color);\n            padding: 20px;\n            margin: 25px 0;\n            border-radius: 4px;\n        }\n\n        .highlight-box h3 {\n            margin-top: 0;\n            color: var(--highlight-color);\n        }\n\n        table {\n            width: 100%;\n            border-collapse: collapse;\n            margin: 25px 0;\n            background-color: var(--bg-primary);\n            box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n        }\n\n        th {\n            background-color: var(--table-header);\n            color: #ffffff;\n            padding: 14px 12px;\n            text-align: left;\n            font-weight: 600;\n            font-size: 0.9em;\n            text-transform: uppercase;\n            letter-spacing: 0.5px;\n            border: 1px solid var(--border-color);\n        }\n\n        td {\n            padding: 12px;\n            border: 1px solid var(--border-color);\n            font-size: 0.95em;\n        }\n\n        tr:hover {\n            background-color: var(--table-hover);\n        }\n\n        .table-responsive {\n            overflow-x: auto;\n            margin: 20px 0;\n        }\n\n        .specs-grid {\n            display: grid;\n            grid-template-columns: repeat(auto-fit, minmax(280px, 1fr));\n            gap: 20px;\n            margin: 25px 0;\n        }\n\n        .spec-card {\n            background-color: var(--bg-secondary);\n            padding: 20px;\n            border-radius: 4px;\n            border-left: 4px solid var(--accent-color);\n        }\n\n        .spec-card.highlight {\n            border-left-color: var(--highlight-color);\n        }\n\n        .spec-card h4 {\n            font-size: 1.1em;\n            margin-bottom: 12px;\n            color: var(--accent-color);\n            font-weight: 600;\n        }\n\n        .spec-card.highlight h4 {\n            color: var(--highlight-color);\n        }\n\n        .spec-card p {\n            margin: 8px 0;\n            font-size: 0.95em;\n        }\n\n        .standards-list {\n            background-color: var(--bg-secondary);\n            padding: 25px;\n            border-radius: 4px;\n            margin: 20px 0;\n        }\n\n        .standards-list ul {\n            list-style-position: inside;\n            margin-left: 0;\n        }\n\n        .standards-list li {\n            padding: 8px 0;\n            border-bottom: 1px solid var(--border-color);\n        }\n\n        .standards-list li:last-child {\n            border-bottom: none;\n        }\n\n        .construction-diagram {\n            background-color: var(--bg-secondary);\n            padding: 30px;\n            border-radius: 4px;\n            margin: 30px 0;\n        }\n\n        .construction-item {\n            display: grid;\n            grid-template-columns: 80px 1fr;\n            gap: 15px;\n            padding: 15px 0;\n            border-bottom: 1px solid var(--border-color);\n        }\n\n        .construction-item:last-child {\n            border-bottom: none;\n        }\n\n        .construction-number {\n            font-size: 1.5em;\n            font-weight: 700;\n            color: var(--accent-color);\n            text-align: center;\n        }\n\n        .construction-desc h4 {\n            color: var(--text-primary);\n            margin-bottom: 5px;\n            font-size: 1.05em;\n        }\n\n        .construction-desc p {\n            margin: 0;\n            color: var(--text-secondary);\n            font-size: 0.95em;\n        }\n\n        .contact-section {\n            background-color: var(--bg-secondary);\n            padding: 30px;\n            border-radius: 4px;\n            margin: 40px 0;\n        }\n\n        .contact-grid {\n            display: grid;\n            grid-template-columns: repeat(auto-fit, minmax(250px, 1fr));\n            gap: 20px;\n            margin-top: 20px;\n        }\n\n        .contact-item {\n            padding: 15px;\n            background-color: var(--bg-primary);\n            border-radius: 4px;\n        }\n\n        .contact-item strong {\n            color: var(--accent-color);\n            display: block;\n            margin-bottom: 8px;\n        }\n\n        a {\n            color: var(--link-color);\n            text-decoration: none;\n            transition: opacity 0.2s ease;\n        }\n\n        a:hover {\n            opacity: 0.7;\n            text-decoration: underline;\n        }\n\n        .references {\n            margin-top: 50px;\n            padding: 25px;\n            background-color: var(--bg-secondary);\n            border-radius: 4px;\n        }\n\n        .references h3 {\n            margin-top: 0;\n        }\n\n        .references ol {\n            margin-left: 20px;\n            line-height: 2;\n        }\n\n        .references li {\n            margin: 10px 0;\n        }\n\n        .note {\n            background-color: var(--bg-secondary);\n            padding: 15px 20px;\n            border-left: 4px solid var(--highlight-color);\n            margin: 20px 0;\n            font-style: italic;\n        }\n\n        .feature-badge {\n            display: inline-block;\n            background-color: var(--highlight-color);\n            color: white;\n            padding: 4px 10px;\n            border-radius: 3px;\n            font-size: 0.85em;\n            font-weight: 600;\n            margin: 2px;\n        }\n\n        footer {\n            margin-top: 60px;\n            padding: 30px 0;\n            border-top: 2px solid var(--border-color);\n            text-align: center;\n            color: var(--text-secondary);\n        }\n\n        @media (max-width: 768px) {\n            h1 {\n                font-size: 1.6em;\n            }\n            h2 {\n                font-size: 1.4em;\n            }\n            .specs-grid,\n            .contact-grid {\n                grid-template-columns: 1fr;\n            }\n            table {\n                font-size: 0.85em;\n            }\n            th, td {\n                padding: 8px 6px;\n            }\n            .construction-item {\n                grid-template-columns: 60px 1fr;\n            }\n        }\n    <\/style>\n<\/head>\n<body>\n    <header>\n        <div class=\"header-content\">\n            <h1>TROMMELFLEX-M-PUR BRAIDED D2X11Y 1 KV<\/h1>\n            <div class=\"subtitle\">Flexible Low Voltage Reeling Cable with Halogen-Free Polyurethane Sheath<\/div>\n            <div class=\"chinese-title\">TROMMELFLEX-M-PUR\u67d4\u6027\u4f4e\u538b\u5377\u7b52\u7535\u7f06 \u00b7 \u65e0\u5364\u805a\u6c28\u916f\u62a4\u5957 \u00b7 \u5730\u4e0b\u91c7\u77ff\u4e13\u7528<\/div>\n            <div class=\"company-info\">\n                <strong>Anhui Feichun Special Cable Co., Ltd.<\/strong><br>\n                <span style=\"font-size: 0.9em;\">\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/span>\n            <\/div>\n        <\/div>\n    <\/header>\n\n    <div class=\"container\">\n        <section class=\"section\">\n            <h2>Product Overview \u4ea7\u54c1\u6982\u8ff0<\/h2>\n            <p class=\"intro-text\">\n                TROMMELFLEX-M-PUR represents a specialized category of flexible low voltage reeling cables engineered specifically for the demanding conditions of underground mining and tunneling operations. This cable features optimized dimensions and a flame-retardant, halogen-free polyurethane outer sheath, making it ideal for power supply to mobile underground equipment including drilling machines, Load-Haul-Dump (LHD) loaders, and scoops that operate under frequently changing dynamic loads during reeling operations.\n            <\/p>\n            <p class=\"intro-text\">\n                TROMMELFLEX-M-PUR\u7535\u7f06\u662f\u4e13\u4e3a\u5730\u4e0b\u91c7\u77ff\u548c\u96a7\u9053\u4f5c\u4e1a\u7684\u82db\u523b\u6761\u4ef6\u800c\u8bbe\u8ba1\u7684\u7279\u79cd\u67d4\u6027\u4f4e\u538b\u5377\u7b52\u7535\u7f06\u3002\u8be5\u7535\u7f06\u5177\u6709\u4f18\u5316\u7684\u5c3a\u5bf8\u8bbe\u8ba1\u548c\u963b\u71c3\u3001\u65e0\u5364\u805a\u6c28\u916f\u5916\u62a4\u5957\uff0c\u7279\u522b\u9002\u5408\u4e3a\u94bb\u673a\u3001\u88c5\u8f7d-\u8fd0\u8f93-\u5378\u8f7d\uff08LHD\uff09\u88c5\u8f7d\u673a\u548c\u94f2\u8fd0\u673a\u7b49\u79fb\u52a8\u5730\u4e0b\u8bbe\u5907\u63d0\u4f9b\u7535\u529b\uff0c\u8fd9\u4e9b\u8bbe\u5907\u5728\u5377\u7ed5\u64cd\u4f5c\u4e2d\u627f\u53d7\u9891\u7e41\u53d8\u5316\u7684\u52a8\u6001\u8d1f\u8f7d\u3002\n            <\/p>\n\n            <div class=\"highlight-box\">\n                <h3>Key Features: Halogen-Free &#038; Optimized Dimensions \u5173\u952e\u7279\u6027\uff1a\u65e0\u5364\u8bbe\u8ba1\u4e0e\u4f18\u5316\u5c3a\u5bf8<\/h3>\n                <p>\n                    <span class=\"feature-badge\">HALOGEN-FREE<\/span> <span class=\"feature-badge\">PUR SHEATH<\/span> <span class=\"feature-badge\">OPTIMIZED SIZE<\/span> <span class=\"feature-badge\">ABRASION RESISTANT<\/span>\n                <\/p>\n                <p>\n                    The TROMMELFLEX-M-PUR cable&#8217;s halogen-free polyurethane sheath provides exceptional advantages in underground mining environments. Unlike conventional cables with PVC or rubber sheaths, the PUR-HF (halogen-free) construction ensures that in the event of fire, the cable releases minimal toxic and corrosive gases, protecting both personnel and sensitive equipment in confined underground spaces. The optimized dimensions allow for smaller cable reeling drums, reducing equipment size and installation costs while maintaining the robust mechanical properties required for underground trailing applications.\n                <\/p>\n                <p style=\"margin-top: 10px;\">\n                    \u4e0e\u4f20\u7edf\u7684PVC\u6216\u6a61\u80f6\u62a4\u5957\u7535\u7f06\u4e0d\u540c\uff0cTROMMELFLEX-M-PUR\u7684\u65e0\u5364\u805a\u6c28\u916f\u62a4\u5957\u5728\u53d1\u751f\u706b\u707e\u65f6\u91ca\u653e\u7684\u6709\u6bd2\u548c\u8150\u8680\u6027\u6c14\u4f53\u6700\u5c11\uff0c\u5728\u72ed\u7a84\u7684\u5730\u4e0b\u7a7a\u95f4\u4e2d\u4fdd\u62a4\u4eba\u5458\u548c\u654f\u611f\u8bbe\u5907\u3002\u4f18\u5316\u7684\u5c3a\u5bf8\u8bbe\u8ba1\u5141\u8bb8\u4f7f\u7528\u66f4\u5c0f\u7684\u7535\u7f06\u5377\u7b52\uff0c\u964d\u4f4e\u8bbe\u5907\u5c3a\u5bf8\u548c\u5b89\u88c5\u6210\u672c\uff0c\u540c\u65f6\u4fdd\u6301\u5730\u4e0b\u62d6\u66f3\u5e94\u7528\u6240\u9700\u7684\u575a\u56fa\u673a\u68b0\u6027\u80fd\u3002\n                <\/p>\n            <\/div>\n        <\/section>\n\n        <section class=\"section\">\n            <h2>Applications &#038; Target Equipment \u5e94\u7528\u573a\u5408\u4e0e\u76ee\u6807\u8bbe\u5907<\/h2>\n            <p>\n                TROMMELFLEX-M-PUR cables are specifically designed for underground mining and tunneling equipment that requires continuous flexible power supply during dynamic operations. According to industry research on underground mining equipment, LHD loaders represent one of the most critical applications for these cables, as they operate with flexible trailing cables that must withstand constant reeling and unreeling cycles while the machine loads, hauls, and dumps broken rock throughout the mine workings.\n            <\/p>\n\n            <div class=\"specs-grid\">\n                <div class=\"spec-card highlight\">\n                    <h4>LHD Loaders \u88c5\u8f7d-\u8fd0\u8f93-\u5378\u8f7d\u673a<\/h4>\n                    <p>Load-Haul-Dump machines are low-profile underground loaders designed to move broken rock efficiently through confined mine workings. Electric LHDs typically operate at 380-550 volts and use flexible trailing cables with reeling\/unreeling facilities to feed power. The TROMMELFLEX-M-PUR cable&#8217;s small diameter and high flexibility make it ideal for the 100-meter cable lengths commonly used with LHD equipment.<\/p>\n                <\/div>\n                <div class=\"spec-card highlight\">\n                    <h4>Underground Drilling Machines \u5730\u4e0b\u94bb\u673a<\/h4>\n                    <p>Drilling machines used for development, production drilling, and ground support installation require flexible power cables that can withstand the continuous reeling operations as the machine advances through the mine. The cable must handle abrasion from contact with rough rock surfaces and maintain electrical performance despite repeated bending cycles.<\/p>\n                <\/div>\n                <div class=\"spec-card highlight\">\n                    <h4>Scoop Trams \u94f2\u8fd0\u673a<\/h4>\n                    <p>Scoop trams (another term for LHD loaders) are the workhorses of underground mining, used for mucking operations in narrow headings where space is limited. The articulated design and continuous operation require cables with excellent flexibility, small bending radius, and resistance to mechanical stress from trailing operations.<\/p>\n                <\/div>\n                <div class=\"spec-card highlight\">\n                    <h4>Tunneling Equipment \u96a7\u9053\u6398\u8fdb\u8bbe\u5907<\/h4>\n                    <p>Tunnel boring machines and roadheaders require reliable power cables that can handle the demanding conditions of tunneling operations including exposure to water, abrasive materials, and continuous machine movement. The halogen-free sheath ensures safety in the confined tunnel environment.<\/p>\n                <\/div>\n            <\/div>\n        <\/section>\n\n        <section class=\"section\">\n            <h2>Standards &#038; Approvals \u6807\u51c6\u4e0e\u8ba4\u8bc1<\/h2>\n            <div class=\"standards-list\">\n                <ul>\n                    <li><strong>DIN EN 60228 \/ IEC 60228 \/ VDE 0295<\/strong> &#8211; Conductor specifications defining conductor classes and resistance values for flexible cables<\/li>\n                    <li><strong>DIN VDE 0298-300<\/strong> &#8211; Core identification standards for power cables ensuring proper installation and maintenance<\/li>\n                    <li><strong>IEC 60502-1<\/strong> &#8211; Compound specifications for insulation and sheathing materials used in power cables<\/li>\n                    <li><strong>DIN VDE 0298-4<\/strong> &#8211; Electrical parameters including current carrying capacity and voltage drop calculations<\/li>\n                    <li><strong>DIN EN 60332-1-2 \/ IEC 60332-1-2<\/strong> &#8211; Fire performance testing for vertical flame propagation, ensuring cables do not support flame spread<\/li>\n                <\/ul>\n            <\/div>\n            <p class=\"note\">\n                Note: Compliance with these internationally recognized standards ensures the TROMMELFLEX-M-PUR cable meets the stringent safety and performance requirements of underground mining operations worldwide. The halogen-free designation is particularly important for confined space applications where toxic gas generation must be minimized in fire scenarios.\n            <\/p>\n        <\/section>\n\n        <section class=\"section\">\n            <h2>Cable Construction \u7535\u7f06\u7ed3\u6784<\/h2>\n            <p>\n                The TROMMELFLEX-M-PUR cable features an advanced multi-layer construction specifically optimized for underground mining reeling applications. The use of XLPE (cross-linked polyethylene) insulation combined with polyurethane sheathing provides superior mechanical and chemical resistance compared to traditional rubber-insulated cables, while the central aramid reinforcement ensures the cable can withstand the high tensile loads encountered during reeling operations.\n            <\/p>\n            \n            <div class=\"construction-diagram\">\n                <h3 style=\"margin-top: 0; margin-bottom: 20px;\">Layer-by-Layer Construction \u9010\u5c42\u7ed3\u6784\u8bf4\u660e<\/h3>\n                \n                <div class=\"construction-item\">\n                    <div class=\"construction-number\">1<\/div>\n                    <div class=\"construction-desc\">\n                        <h4>Central Aramid Element \u4e2d\u592e\u82b3\u7eb6\u5143\u4ef6<\/h4>\n                        <p>High-strength aramid fiber carrier element positioned at the cable center provides exceptional tensile strength and prevents conductor elongation during reeling operations. The aramid reinforcement allows the cable to support its own weight and resist pulling forces up to 25 N\/mm\u00b2.<\/p>\n                    <\/div>\n                <\/div>\n\n                <div class=\"construction-item\">\n                    <div class=\"construction-number\">2<\/div>\n                    <div class=\"construction-desc\">\n                        <h4>Conductor \u5bfc\u4f53<\/h4>\n                        <p>Finely stranded bare copper conductor, Class 5 according to IEC 60228. The fine stranding (many thin wires) provides maximum flexibility essential for continuous bending during reeling cycles while maintaining excellent electrical conductivity and mechanical durability.<\/p>\n                    <\/div>\n                <\/div>\n\n                <div class=\"construction-item\">\n                    <div class=\"construction-number\">3<\/div>\n                    <div class=\"construction-desc\">\n                        <h4>XLPE Insulation XLPE\u7edd\u7f18<\/h4>\n                        <p>Cross-linked polyethylene (XLPE) provides excellent electrical insulation with superior thermal performance (90\u00b0C continuous, 250\u00b0C short circuit). XLPE offers better resistance to water, chemicals, and thermal aging compared to conventional PVC or rubber insulation materials.<\/p>\n                    <\/div>\n                <\/div>\n\n                <div class=\"construction-item\">\n                    <div class=\"construction-number\">4<\/div>\n                    <div class=\"construction-desc\">\n                        <h4>Core Arrangement \u82af\u7ebf\u6392\u5217<\/h4>\n                        <p>Three main conductors (brown, black, grey) laid up together with split earth conductor in the interstices around the central aramid carrier. The cores are twisted with very short length of lay, providing enhanced flexibility and preventing individual conductor stress during bending.<\/p>\n                    <\/div>\n                <\/div>\n\n                <div class=\"construction-item\">\n                    <div class=\"construction-number\">5<\/div>\n                    <div class=\"construction-desc\">\n                        <h4>Earth Conductor \u63a5\u5730\u5bfc\u4f53<\/h4>\n                        <p>Split earth conductors positioned in the interstices between power cores provide comprehensive grounding throughout the cable length, essential for personnel safety in underground mining environments. The earth conductors are sized according to IEC standards for adequate fault protection.<\/p>\n                    <\/div>\n                <\/div>\n\n                <div class=\"construction-item\">\n                    <div class=\"construction-number\">6<\/div>\n                    <div class=\"construction-desc\">\n                        <h4>Inner Sheath \u5185\u62a4\u5957<\/h4>\n                        <p>Halogen-free polymer inner sheath provides additional mechanical protection for the conductor assembly and serves as a barrier against moisture ingress. This layer also helps maintain the cable&#8217;s round cross-section during bending operations.<\/p>\n                    <\/div>\n                <\/div>\n\n                <div class=\"construction-item\">\n                    <div class=\"construction-number\">7<\/div>\n                    <div class=\"construction-desc\">\n                        <h4>Braiding \u7f16\u7ec7\u5c42<\/h4>\n                        <p>Textile braiding between inner and outer sheaths provides anti-twist protection and additional tensile strength. The braiding helps distribute mechanical stresses evenly across the cable and prevents the outer sheath from rotating relative to the inner core assembly during torsional loading.<\/p>\n                    <\/div>\n                <\/div>\n\n                <div class=\"construction-item\">\n                    <div class=\"construction-number\">8<\/div>\n                    <div class=\"construction-desc\">\n                        <h4>Outer Sheath PUR \u5916\u62a4\u5957\u805a\u6c28\u916f<\/h4>\n                        <p>Special polyurethane (PUR) outer sheath, flame-resistant and halogen-free. The PUR sheath provides outstanding resistance to abrasion, oils, chemicals, UV radiation, and ozone while remaining flexible at low temperatures down to -30\u00b0C. The halogen-free formulation ensures minimal toxic gas generation in fire scenarios.<\/p>\n                    <\/div>\n                <\/div>\n            <\/div>\n        <\/section>\n\n        <section class=\"section\">\n            <h2>Technical Parameters \u6280\u672f\u53c2\u6570<\/h2>\n            \n            <h3>Thermal Parameters \u70ed\u53c2\u6570<\/h3>\n            <div class=\"table-responsive\">\n                <table>\n                    <thead>\n                        <tr>\n                            <th>Parameter \u53c2\u6570<\/th>\n                            <th>Value \u6570\u503c<\/th>\n                            <th>Notes \u5907\u6ce8<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr>\n                            <td>Max. conductor temperature \u6700\u5927\u5bfc\u4f53\u6e29\u5ea6<\/td>\n                            <td>90\u00b0C<\/td>\n                            <td>Continuous operation \u8fde\u7eed\u8fd0\u884c<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Max. conductor temperature at short circuit \u77ed\u8def\u65f6\u6700\u5927\u5bfc\u4f53\u6e29\u5ea6<\/td>\n                            <td>250\u00b0C<\/td>\n                            <td>Short-term condition (5 seconds) \u77ed\u65f6\u72b6\u6001\uff085\u79d2\uff09<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Ambient temperature fixed installation (min) \u56fa\u5b9a\u5b89\u88c5\u6700\u4f4e\u73af\u5883\u6e29\u5ea6<\/td>\n                            <td>-40\u00b0C<\/td>\n                            <td>Static application \u9759\u6001\u5e94\u7528<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Ambient temperature fixed installation (max) \u56fa\u5b9a\u5b89\u88c5\u6700\u9ad8\u73af\u5883\u6e29\u5ea6<\/td>\n                            <td>80\u00b0C<\/td>\n                            <td>Static application \u9759\u6001\u5e94\u7528<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Ambient temperature flexible installation (min) \u79fb\u52a8\u5b89\u88c5\u6700\u4f4e\u73af\u5883\u6e29\u5ea6<\/td>\n                            <td>-30\u00b0C<\/td>\n                            <td>Dynamic reeling operation \u52a8\u6001\u5377\u7ed5\u64cd\u4f5c<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Ambient temperature flexible installation (max) \u79fb\u52a8\u5b89\u88c5\u6700\u9ad8\u73af\u5883\u6e29\u5ea6<\/td>\n                            <td>80\u00b0C<\/td>\n                            <td>Dynamic reeling operation \u52a8\u6001\u5377\u7ed5\u64cd\u4f5c<\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n            <\/div>\n\n            <h3>Chemical &#038; Environmental Parameters \u5316\u5b66\u4e0e\u73af\u5883\u53c2\u6570<\/h3>\n            <div class=\"table-responsive\">\n                <table>\n                    <thead>\n                        <tr>\n                            <th>Property \u6027\u80fd<\/th>\n                            <th>Performance \u8868\u73b0<\/th>\n                            <th>Significance \u91cd\u8981\u6027<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr>\n                            <td>Halogen free \u65e0\u5364<\/td>\n                            <td>Yes \u662f<\/td>\n                            <td>Critical for underground safety &#8211; minimal toxic gas in fire<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Ozone resistance \u8010\u81ed\u6c27\u6027<\/td>\n                            <td>Yes \u662f<\/td>\n                            <td>Prevents degradation in environments with electrical equipment<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Resistant to UV \u6297\u7d2b\u5916\u7ebf<\/td>\n                            <td>Yes \u662f<\/td>\n                            <td>Suitable for portal areas with natural light exposure<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Max. water depth \u6700\u5927\u6d78\u6c34\u6df1\u5ea6<\/td>\n                            <td>10 m<\/td>\n                            <td>Can operate in flooded mine sections and tunnel construction<\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n            <\/div>\n\n            <h3>Mechanical Parameters \u673a\u68b0\u53c2\u6570<\/h3>\n            <div class=\"table-responsive\">\n                <table>\n                    <thead>\n                        <tr>\n                            <th>Parameter \u53c2\u6570<\/th>\n                            <th>Value \u6570\u503c<\/th>\n                            <th>Application Relevance \u5e94\u7528\u76f8\u5173\u6027<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr>\n                            <td>Torsional stress \u626d\u8f6c\u5e94\u529b<\/td>\n                            <td>+\/- 50\u00b0\/m<\/td>\n                            <td>Handles cable twisting during equipment articulation and movement<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Permanent tensile strength \u6c38\u4e45\u6297\u62c9\u5f3a\u5ea6<\/td>\n                            <td>25 N\/mm\u00b2<\/td>\n                            <td>Higher than medium voltage cables due to optimized construction<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Travel speed (reeling operation underground) \u5377\u7ed5\u64cd\u4f5c\u901f\u5ea6\uff08\u5730\u4e0b\uff09<\/td>\n                            <td>100 m\/min<\/td>\n                            <td>Matches typical LHD loader tramming speeds in underground mines<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Bending radius (fixed installation) \u5f2f\u66f2\u534a\u5f84\uff08\u56fa\u5b9a\u5b89\u88c5\uff09<\/td>\n                            <td>4 \u00d7 D (Acc. to VDE 0298-3)<\/td>\n                            <td>Compact installation in confined underground spaces<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Bending radius (reeling operation) \u5f2f\u66f2\u534a\u5f84\uff08\u5377\u7ed5\u64cd\u4f5c\uff09<\/td>\n                            <td>8 \u00d7 D<\/td>\n                            <td>Smaller than traditional cables, enables smaller drum diameters<\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n            <\/div>\n\n            <h3>Electrical Parameters \u7535\u6c14\u53c2\u6570<\/h3>\n            <div class=\"table-responsive\">\n                <table>\n                    <thead>\n                        <tr>\n                            <th>Parameter \u53c2\u6570<\/th>\n                            <th>Value \u6570\u503c<\/th>\n                            <th>Notes \u5907\u6ce8<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr>\n                            <td>Rated voltage U\u2080\/U (U\u2098) \u989d\u5b9a\u7535\u538b<\/td>\n                            <td>0.6\/1 (1.2) kV<\/td>\n                            <td>Low voltage classification<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Test voltage \u8bd5\u9a8c\u7535\u538b<\/td>\n                            <td>2.5 kV<\/td>\n                            <td>AC test voltage for power cores<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>AC test voltage (control cores) \u63a7\u5236\u82af\u7ebf\u8bd5\u9a8c\u7535\u538b<\/td>\n                            <td>2 kV<\/td>\n                            <td>For cables with integrated control conductors<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Nominal voltage U \u6807\u79f0\u7535\u538b<\/td>\n                            <td>1,000 V<\/td>\n                            <td>Typical for underground mining equipment<\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n            <\/div>\n        <\/section>\n\n        <section class=\"section\">\n            <h2>Cable Properties &#8211; Detailed Specifications \u7535\u7f06\u6027\u80fd\u8be6\u7ec6\u89c4\u683c<\/h2>\n            <p>\n                The following table provides comprehensive technical specifications for various TROMMELFLEX-M-PUR cable configurations. Each configuration is optimized for specific current requirements and application needs in underground mining. The D2X11Y designation indicates the cable construction type, with optimized dimensions allowing for smaller cable reels and reduced equipment costs compared to traditional NSHT\u00d6U cables.\n            <\/p>\n\n            <h3>TROMMELFLEX-M-PUR D2X11Y 0.6\/1KV Specifications<\/h3>\n            <div class=\"table-responsive\">\n                <table>\n                    <thead>\n                        <tr>\n                            <th>Construction<br>\u6784\u9020<\/th>\n                            <th>Conductor \u00d8<br>\u5bfc\u4f53\u76f4\u5f84<br>(mm)<\/th>\n                            <th>Cable \u00d8 (min)<br>\u7535\u7f06\u6700\u5c0f\u5916\u5f84<br>(mm)<\/th>\n                            <th>Cable \u00d8 (max)<br>\u7535\u7f06\u6700\u5927\u5916\u5f84<br>(mm)<\/th>\n                            <th>Cable Weight<br>\u7535\u7f06\u91cd\u91cf<br>(kg\/km)<\/th>\n                            <th>Max. Tensile<br>\u6700\u5927\u6297\u62c9\u5f3a\u5ea6<br>(N)<\/th>\n                            <th>Bending Radius<br>\u5f2f\u66f2\u534a\u5f84<br>(mm)<\/th>\n                            <th>Resistance<br>\u7535\u963b at 20\u00b0C<br>(\u03a9\/km)<\/th>\n                            <th>Current<br>\u8f7d\u6d41\u91cf<br>(A)<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr>\n                            <td>3&#215;25+3G6<\/td>\n                            <td>6.2<\/td>\n                            <td>23<\/td>\n                            <td>25<\/td>\n                            <td>1,215<\/td>\n                            <td>1,875<\/td>\n                            <td>200<\/td>\n                            <td>0.78<\/td>\n                            <td>131<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>3&#215;50+3G10<\/td>\n                            <td>9.6<\/td>\n                            <td>30.5<\/td>\n                            <td>32.5<\/td>\n                            <td>2,250<\/td>\n                            <td>3,750<\/td>\n                            <td>260<\/td>\n                            <td>0.386<\/td>\n                            <td>202<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>3&#215;70+3G16<\/td>\n                            <td>11.1<\/td>\n                            <td>35.5<\/td>\n                            <td>37.5<\/td>\n                            <td>3,210<\/td>\n                            <td>5,250<\/td>\n                            <td>300<\/td>\n                            <td>0.272<\/td>\n                            <td>250<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>3&#215;95+3G16<\/td>\n                            <td>12.6<\/td>\n                            <td>39.5<\/td>\n                            <td>42.5<\/td>\n                            <td>3,925<\/td>\n                            <td>7,125<\/td>\n                            <td>340<\/td>\n                            <td>0.206<\/td>\n                            <td>301<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>3&#215;25+3G6+2X1<\/td>\n                            <td>6.2<\/td>\n                            <td>23<\/td>\n                            <td>24.5<\/td>\n                            <td>1,243<\/td>\n                            <td>1,875<\/td>\n                            <td>196<\/td>\n                            <td>0.78<\/td>\n                            <td>131<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>3&#215;35+3G6+2X1,5<\/td>\n                            <td>7.8<\/td>\n                            <td>26.5<\/td>\n                            <td>28<\/td>\n                            <td>1,570<\/td>\n                            <td>2,100<\/td>\n                            <td>224<\/td>\n                            <td>0.554<\/td>\n                            <td>162<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>3&#215;50+3G10+2X1,5<\/td>\n                            <td>9.6<\/td>\n                            <td>30.5<\/td>\n                            <td>32.5<\/td>\n                            <td>2,376<\/td>\n                            <td>3,750<\/td>\n                            <td>260<\/td>\n                            <td>0.386<\/td>\n                            <td>202<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>3&#215;70+3G16+2X1,5<\/td>\n                            <td>11.1<\/td>\n                            <td>35.5<\/td>\n                            <td>37.5<\/td>\n                            <td>3,355<\/td>\n                            <td>5,250<\/td>\n                            <td>300<\/td>\n                            <td>0.272<\/td>\n                            <td>250<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>3&#215;95+3G16+2X1,5<\/td>\n                            <td>12.6<\/td>\n                            <td>40<\/td>\n                            <td>42.5<\/td>\n                            <td>4,059<\/td>\n                            <td>7,125<\/td>\n                            <td>340<\/td>\n                            <td>0.206<\/td>\n                            <td>301<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>3&#215;120+3G25+2X1,5<\/td>\n                            <td>14.8<\/td>\n                            <td>44.5<\/td>\n                            <td>47<\/td>\n                            <td>5,291<\/td>\n                            <td>9,000<\/td>\n                            <td>376<\/td>\n                            <td>0.161<\/td>\n                            <td>352<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>3&#215;150+3G25+2X1,5<\/td>\n                            <td>16<\/td>\n                            <td>49.5<\/td>\n                            <td>52.5<\/td>\n                            <td>6,358<\/td>\n                            <td>11,250<\/td>\n                            <td>420<\/td>\n                            <td>0.129<\/td>\n                            <td>404<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>3&#215;185+3G35+2X1,5<\/td>\n                            <td>17.7<\/td>\n                            <td>54<\/td>\n                            <td>56.5<\/td>\n                            <td>8,030<\/td>\n                            <td>13,875<\/td>\n                            <td>452<\/td>\n                            <td>0.106<\/td>\n                            <td>461<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>3&#215;240+3G50+2X1,5<\/td>\n                            <td>20.2<\/td>\n                            <td>62<\/td>\n                            <td>65<\/td>\n                            <td>10,560<\/td>\n                            <td>18,000<\/td>\n                            <td>520<\/td>\n                            <td>0.0801<\/td>\n                            <td>540<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>4&#215;16<\/td>\n                            <td>5.1<\/td>\n                            <td>22<\/td>\n                            <td>23.5<\/td>\n                            <td>900<\/td>\n                            <td>1,600<\/td>\n                            <td>188<\/td>\n                            <td>1.21<\/td>\n                            <td>99<\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n            <\/div>\n\n            <p class=\"note\">\n                <strong>Note on Cable Configurations \u7535\u7f06\u914d\u7f6e\u8bf4\u660e:<\/strong> The &#8220;3G&#8221; designation indicates three earth conductors, while &#8220;+2X1&#8221; or &#8220;+2X1.5&#8221; indicates additional control cores for remote operation, pilot wire earth continuity monitoring, or auxiliary control circuits common in LHD loaders and drilling machines. The 4&#215;16 configuration provides a compact solution for lighter-duty applications or auxiliary equipment.\n            <\/p>\n        <\/section>\n\n        <section class=\"section\">\n            <h2>Technical Advantages for Underground Mining \u5730\u4e0b\u91c7\u77ff\u6280\u672f\u4f18\u52bf<\/h2>\n            <p>\n                The TROMMELFLEX-M-PUR cable incorporates several advanced engineering features that provide significant operational advantages in underground mining environments. Research on polyurethane sheathed cables demonstrates that PUR-HF cables offer superior performance compared to traditional rubber (NSHT\u00d6U) cables, particularly in applications requiring frequent reeling cycles and exposure to harsh underground conditions.\n            <\/p>\n\n            <div class=\"specs-grid\">\n                <div class=\"spec-card highlight\">\n                    <h4>Optimized Dimensions \u4f18\u5316\u5c3a\u5bf8<\/h4>\n                    <p>The use of XLPE insulation and PUR sheathing allows for significantly smaller outside diameters compared to traditional rubber-insulated cables. This enables the use of smaller, more cost-effective cable reeling drums, reducing the size and weight of equipment that must be transported underground and lowering capital equipment costs.<\/p>\n                <\/div>\n                <div class=\"spec-card highlight\">\n                    <h4>Superior Abrasion Resistance \u5353\u8d8a\u8010\u78e8\u6027<\/h4>\n                    <p>Polyurethane sheathing provides exceptional resistance to abrasion, cuts, and tears compared to conventional rubber materials. In trailing operations where the cable drags across rough underground surfaces, this dramatically extends cable service life and reduces the frequency of cable replacements, lowering operational costs.<\/p>\n                <\/div>\n                <div class=\"spec-card highlight\">\n                    <h4>Enhanced Safety &#8211; Halogen-Free \u589e\u5f3a\u5b89\u5168\u6027-\u65e0\u5364<\/h4>\n                    <p>The halogen-free construction ensures minimal toxic and corrosive gas generation in fire scenarios. In confined underground spaces where ventilation is limited and evacuation routes may be restricted, this feature significantly improves personnel safety and reduces damage to expensive mining equipment and infrastructure.<\/p>\n                <\/div>\n                <div class=\"spec-card highlight\">\n                    <h4>Reduced Weight \u51cf\u8f7b\u91cd\u91cf<\/h4>\n                    <p>TROMMELFLEX-M-PUR cables are significantly lighter than equivalent rubber-insulated cables. The reduced weight decreases the load on cable reeling systems, extends equipment service life, reduces energy consumption during reeling operations, and simplifies cable handling during installation and maintenance.<\/p>\n                <\/div>\n                <div class=\"spec-card highlight\">\n                    <h4>Chemical Resistance \u5316\u5b66\u8010\u53d7\u6027<\/h4>\n                    <p>The PUR sheath provides outstanding resistance to oils, hydraulic fluids, coolants, and other chemicals commonly encountered in underground mining. This resistance prevents sheath degradation and maintains cable integrity even when exposed to petroleum products from hydraulic systems on LHD loaders and drilling equipment.<\/p>\n                <\/div>\n                <div class=\"spec-card highlight\">\n                    <h4>Wide Temperature Range \u5bbd\u6e29\u5ea6\u8303\u56f4<\/h4>\n                    <p>With operating capability from -30\u00b0C to +80\u00b0C in dynamic applications, the cable performs reliably in cold underground environments (particularly in mines at high elevations or in cold climates) as well as in high-temperature zones near geothermal gradients or equipment generating significant heat.<\/p>\n                <\/div>\n            <\/div>\n        <\/section>\n\n        <section class=\"section\">\n            <h2>Comparison with Traditional Cables \u4e0e\u4f20\u7edf\u7535\u7f06\u7684\u6bd4\u8f83<\/h2>\n            <div class=\"table-responsive\">\n                <table>\n                    <thead>\n                        <tr>\n                            <th>Feature \u7279\u6027<\/th>\n                            <th>TROMMELFLEX-M-PUR<\/th>\n                            <th>Traditional NSHT\u00d6U<\/th>\n                            <th>Advantage \u4f18\u52bf<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr>\n                            <td>Outer diameter \u5916\u5f84<\/td>\n                            <td>Optimized (smaller) \u4f18\u5316\uff08\u66f4\u5c0f\uff09<\/td>\n                            <td>Standard (larger) \u6807\u51c6\uff08\u66f4\u5927\uff09<\/td>\n                            <td>Enables smaller reels and lower equipment costs<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Weight \u91cd\u91cf<\/td>\n                            <td>Lighter \u66f4\u8f7b<\/td>\n                            <td>Heavier \u66f4\u91cd<\/td>\n                            <td>Easier handling, reduced reel motor load<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Bending radius \u5f2f\u66f2\u534a\u5f84<\/td>\n                            <td>8D (reeling) 8\u500d\u76f4\u5f84\uff08\u5377\u7ed5\uff09<\/td>\n                            <td>10-12D (typical) 10-12\u500d\u76f4\u5f84\uff08\u5178\u578b\uff09<\/td>\n                            <td>More flexible, smaller drums possible<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Abrasion resistance \u8010\u78e8\u6027<\/td>\n                            <td>Excellent (PUR) \u4f18\u79c0\uff08\u805a\u6c28\u916f\uff09<\/td>\n                            <td>Good (rubber) \u826f\u597d\uff08\u6a61\u80f6\uff09<\/td>\n                            <td>Extended service life in trailing operations<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Halogen content \u5364\u7d20\u542b\u91cf<\/td>\n                            <td>Halogen-free \u65e0\u5364<\/td>\n                            <td>Contains halogens \u542b\u5364\u7d20<\/td>\n                            <td>Safer in fire &#8211; minimal toxic gases<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Chemical resistance \u5316\u5b66\u8010\u53d7<\/td>\n                            <td>Excellent (PUR) \u4f18\u79c0\uff08\u805a\u6c28\u916f\uff09<\/td>\n                            <td>Good (rubber) \u826f\u597d\uff08\u6a61\u80f6\uff09<\/td>\n                            <td>Better resistance to oils and hydraulic fluids<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Low temp flexibility \u4f4e\u6e29\u67d4\u97e7\u6027<\/td>\n                            <td>-30\u00b0C \u96f6\u4e0b30\u6444\u6c0f\u5ea6<\/td>\n                            <td>-25\u00b0C (typical) \u96f6\u4e0b25\u6444\u6c0f\u5ea6\uff08\u5178\u578b\uff09<\/td>\n                            <td>Maintains flexibility in colder mines<\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n            <\/div>\n        <\/section>\n\n        <section class=\"contact-section\">\n            <h2>Contact Information \u8054\u7cfb\u65b9\u5f0f<\/h2>\n            <p>For technical inquiries, quotations, custom cable configurations, or to discuss specific underground mining cable requirements, please contact Anhui Feichun Special Cable Co., Ltd. through any of the following channels. Our engineering team can provide detailed specifications and application support for your mining equipment.<\/p>\n            <div class=\"contact-grid\">\n                <div class=\"contact-item\">\n                    <strong>WhatsApp \/ WeChat<\/strong>\n                    <a href=\"https:\/\/wa.me\/8613855123218\" target=\"_blank\" rel=\"noopener\">+86 138 5512 3218<\/a>\n                <\/div>\n                <div class=\"contact-item\">\n                    <strong>Technical Support \u6280\u672f\u652f\u6301<\/strong>\n                    <a href=\"mailto:tech@feichuncables.com\">tech@feichuncables.com<\/a>\n                <\/div>\n                <div class=\"contact-item\">\n                    <strong>Sales Department \u9500\u552e\u90e8\u95e8<\/strong>\n                    <a href=\"mailto:zihao.yang@feichuncables.com\">zihao.yang@feichuncables.com<\/a>\n                <\/div>\n                <div class=\"contact-item\">\n                    <strong>Engineering Department \u5de5\u7a0b\u90e8\u95e8<\/strong>\n                    <a href=\"mailto:ziyu.huang@feichuncables.com\">ziyu.huang@feichuncables.com<\/a>\n                <\/div>\n            <\/div>\n        <\/section>\n\n        <div class=\"references\">\n            <h3>References &#038; Standards \u53c2\u8003\u6587\u732e\u4e0e\u6807\u51c6<\/h3>\n            <ol>\n                <li>Eland Cables. &#8220;PUR-HF Festoon Cables &#8211; For heavy industrial applications involving reeling.&#8221; Product Overview. <a href=\"https:\/\/www.elandcables.com\/cables\/pur-hf-festoon-cables\" rel=\"nofollow noopener\" target=\"_blank\">Eland PUR-HF Cables<\/a><\/li>\n                <li>Feichun Cable. &#8220;What is Mining, Drilling &#038; Tunnelling Cable? Solutions for Surface, Sub-Surface &#038; Underground Operations.&#8221; Technical Blog. January 2026. <a href=\"https:\/\/feichuncables.com\/blog\/what-is-mining-drilling-tunnelling-cable-solutions-for-surface-sub-surface-underground-operations\/\" rel=\"nofollow\" target=\"_blank\">Mining Cable Solutions<\/a><\/li>\n                <li>Power and Cables. &#8220;Mining Cables Trailing Flexible Reeling &#8211; Underground and surface mine cables.&#8221; Product Guide. February 2025. <a href=\"https:\/\/www.powerandcables.com\/product\/offshore-cables\/mining-cables\/\" rel=\"nofollow noopener\" target=\"_blank\">Mining Cable Guide<\/a><\/li>\n                <li>Wikipedia. &#8220;LHD (load, haul, dump machine) &#8211; Underground Mining Equipment.&#8221; November 2023. <a href=\"https:\/\/en.wikipedia.org\/wiki\/LHD_(load,_haul,_dump_machine)\" rel=\"nofollow noopener\" target=\"_blank\">LHD Equipment Overview<\/a><\/li>\n                <li>An Underground Miner. &#8220;What is a Mining LHD? (Load-Haul-Dump)&#8221; Technical Article. December 2021. <a href=\"https:\/\/anundergroundminer.com\/blog\/what-is-a-mining-lhd\" rel=\"nofollow noopener\" target=\"_blank\">Mining LHD Guide<\/a><\/li>\n                <li>VERI Cable. &#8220;Underground Mining Tunnel Cable Leading Manufacturer.&#8221; Product Catalog. December 2024. <a href=\"https:\/\/vericable.com\/underground-mining-tunnel-cable\/\" rel=\"nofollow noopener\" target=\"_blank\">Underground Mining Cables<\/a><\/li>\n                <li>SAB Cable. &#8220;DR 720 P Highflex &#8211; Reeling Cable with PUR jackets offering superior resistance to abrasion.&#8221; <a href=\"https:\/\/sabcable.com\/cables\/specialty-cables\/reeling-cables\" rel=\"nofollow noopener\" target=\"_blank\">SAB Reeling Cables<\/a><\/li>\n                <li>International Electrotechnical Commission. &#8220;IEC 60228:2004 &#8211; Conductors of insulated cables.&#8221; IEC Standards Database.<\/li>\n                <li>International Electrotechnical Commission. &#8220;IEC 60332-1-2 &#8211; Tests on electric and optical fibre cables under fire conditions &#8211; Part 1-2: Test for vertical flame propagation.&#8221; IEC Standards.<\/li>\n                <li>VDE Verlag. &#8220;DIN VDE 0298-4 &#8211; Use of cables and flexible cords in power installations \u2013 Part 4: Recommended values for current-carrying capacity.&#8221; German Standards.<\/li>\n            <\/ol>\n        <\/div>\n    <\/div>\n\n    <footer>\n        <p>&copy; 2026 Anhui Feichun Special Cable Co., Ltd. (\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8)<\/p>\n        <p>All technical specifications are subject to change without notice. Please contact our engineering team for the most current information and application-specific recommendations.<\/p>\n        <p style=\"margin-top: 10px; font-size: 0.9em;\">Manufactured in accordance with international standards including IEC 60228, IEC 60332-1-2, DIN VDE 0298-4 for underground mining applications<\/p>\n    <\/footer>\n<\/body>\n<\/html>\n\n\n\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/TROMMELFLEX-M-PUR-D2X11Y-Technical-Specification.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"\u5d4c\u5165 TROMMELFLEX-M-PUR D2X11Y - Technical Specification\"><\/object><a id=\"wp-block-file--media-79a92ca4-26a2-4eb3-8fe5-fe0663811c2b\" href=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/TROMMELFLEX-M-PUR-D2X11Y-Technical-Specification.pdf\">TROMMELFLEX-M-PUR D2X11Y &#8211; Technical Specification<\/a><a href=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/TROMMELFLEX-M-PUR-D2X11Y-Technical-Specification.pdf\" class=\"wp-block-file__button wp-element-button\" aria-describedby=\"wp-block-file--media-79a92ca4-26a2-4eb3-8fe5-fe0663811c2b\" download>\u4e0b\u8f7d<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"TROMMELFLEX-M-PUR represents a specialized category of flexible low voltage reeling cables engineered specifically for the demanding conditions of underground mining and tunneling operations. This cable features optimized dimensions and a flame-retardant, halogen-free polyurethane outer sheath, making it ideal for power supply to mobile underground equipment including drilling machines, Load-Haul-Dump (LHD) loaders, and scoops that operate under frequently changing dynamic loads during reeling operations.\nTROMMELFLEX-M-PUR\u7535\u7f06\u662f\u4e13\u4e3a\u5730\u4e0b\u91c7\u77ff\u548c\u96a7\u9053\u4f5c\u4e1a\u7684\u82db\u523b\u6761\u4ef6\u800c\u8bbe\u8ba1\u7684\u7279\u79cd\u67d4\u6027\u4f4e\u538b\u5377\u7b52\u7535\u7f06\u3002\u8be5\u7535\u7f06\u5177\u6709\u4f18\u5316\u7684\u5c3a\u5bf8\u8bbe\u8ba1\u548c\u963b\u71c3\u3001\u65e0\u5364\u805a\u6c28\u916f\u5916\u62a4\u5957\uff0c\u7279\u522b\u9002\u5408\u4e3a\u94bb\u673a\u3001\u88c5\u8f7d-\u8fd0\u8f93-\u5378\u8f7d\uff08LHD\uff09\u88c5\u8f7d\u673a\u548c\u94f2\u8fd0\u673a\u7b49\u79fb\u52a8\u5730\u4e0b\u8bbe\u5907\u63d0\u4f9b\u7535\u529b\uff0c\u8fd9\u4e9b\u8bbe\u5907\u5728\u5377\u7ed5\u64cd\u4f5c\u4e2d\u627f\u53d7\u9891\u7e41\u53d8\u5316\u7684\u52a8\u6001\u8d1f\u8f7d\u3002","protected":false},"author":1,"featured_media":5405,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[66,94,56],"tags":[39371,989,39347,39364,39350,39358,39362,771,39377,2484,39345,24918,39380,39355,960,1237,18987,1111,39367,39329,16,594,39326,12164,39375,171,774,778,7700,152,32764,107,39348,2924,39383,7624,2326,8989,1149,111,139,214,204,1696,796,39361,35015,24381,28207,39353,17,39351,39384,14327,5525,994,8967,39327,39328,1702,1091,808,817,19039,39342,39349,39363,39346,39370,39343,22788,39352,39338,11987,39378,10130,39359,39376,39382,39381,39341,36424,39374,11983,19241,39360,39369,39339,27288,27095,31718,39344,39356,39357,22666,32847,39373,39336,39337,39368,39379,39372,39340,11985,39354,39366,22332,22789],"class_list":["post-6070","post","type-post","status-publish","format-standard","has-post-thumbnail","category-common-problems-encountered-in-cable-applications","category-din-vde-0250-mining-cable","category-reeling-cable","tag-30c-to-90c-cable","tag-0-6-1kv-cable","tag-1-kv-mining-cable","tag-3x253g6-cable","tag-3x503g10-cable","tag-3x953g16-cable","tag-39362","tag-abrasion-resistant-cable","tag-alternative-to-nshtou-cable","tag-anhui-feichun-special-cable","tag-bending-radius-8d","tag-braided-cable","tag-cable-with-control-cores","tag-central-aramid-reinforcement","tag-chemical-resistant-mining-cable","tag-coal-mining-cable","tag-confined-space-cable","tag-construction-equipment-cable","tag-custom-configured-cable","tag-d2x11y-cable","tag-din-vde-0250","tag-din-vde-0298-4","tag-drilling-machine-cable","tag-dynamic-load-cable","tag-equipment-power-supply-cable","tag-explosion-proof-mining-cable","tag-flame-retardant-cable","tag-flexible-mining-cable","tag-halogen-free-cable-2","tag-heavy-duty-mining-cable","tag-heavy-duty-reeling-cable-2","tag-heavy-duty-e-loader-mining-cable","tag-high-tensile-strength-25-n-mm","tag-iec-60228-class-5-conductor","tag-iec-60332-1-2-compliant","tag-lhd-loader-cable","tag-long-service-life-cable","tag-low-voltage-reeling-cable","tag-metal-mining-cable","tag-mining-cable","tag-mining-cables","tag-mining-power-cable","tag-mining-trailing-cable","tag-mobile-equipment-cable","tag-oil-resistant-cable","tag-optimized-dimensions-cable","tag-pur-advantages","tag-pur-sheathed-cable","tag-real-time-monitoring-cable","tag-reduced-maintenance-cable","tag-reeling-cable","tag-reeling-speed-100-m-min","tag-safe-production-cable","tag-scoop-cable","tag-split-earth-conductor-cable","tag-trailing-cable","tag-trommelflex-pur","tag-trommelflex-m-pur","tag-trommelflex-m-pur-d2x11y","tag-tunneling-cable","tag-underground-mining-cable","tag-uv-resistant-cable","tag-xlpe-insulated-cable","tag-xlpe","tag-39342","tag-39349","tag-39363","tag-39346","tag-39370","tag-39343","tag-22788","tag-39352","tag-39338","tag-11987","tag-39378","tag-10130","tag-39359","tag-39376","tag-39382","tag-39381","tag-39341","tag-36424","tag-39374","tag-11983","tag-19241","tag-nshtou","tag-39369","tag-39339","tag-27288","tag-27095","tag-31718","tag-39344","tag-39356","tag-39357","tag-22666","tag-32847","tag-39373","tag-39336","tag-39337","tag-39368","tag-39379","tag-39372","tag-39340","tag-11985","tag-39354","tag-39366","tag-22332","tag-22789","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/6070","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=6070"}],"version-history":[{"count":1,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/6070\/revisions"}],"predecessor-version":[{"id":6072,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/6070\/revisions\/6072"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/5405"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=6070"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=6070"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=6070"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}