{"id":5510,"date":"2026-01-30T14:05:33","date_gmt":"2026-01-30T06:05:33","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=5510"},"modified":"2026-01-30T14:05:38","modified_gmt":"2026-01-30T06:05:38","slug":"amercable-tiger-brand-can-i-interchange-amercable-tiger-brand-type-w-with-standard-type-w-portable-power-cable","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/amercable-tiger-brand-can-i-interchange-amercable-tiger-brand-type-w-with-standard-type-w-portable-power-cable\/","title":{"rendered":"AmerCable Tiger Brand: Can I Interchange AmerCable Tiger Brand Type W with Standard Type W Portable Power Cable?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">AmerCable \u864e\u724c\u7535\u7f06\uff1a\u864e\u724cType W\u4e0e\u6807\u51c6Type W\u4fbf\u643a\u5f0f\u7535\u529b\u7535\u7f06\u53ef\u4ee5\u4e92\u6362\u4f7f\u7528\u5417\uff1f<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-dominant-color=\"8b9194\" data-has-transparency=\"false\" style=\"--dominant-color: #8b9194;\" loading=\"lazy\" decoding=\"async\" width=\"929\" height=\"628\" sizes=\"auto, (max-width: 929px) 100vw, 929px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-701-929x628.avif\" alt=\"\" class=\"wp-image-5512 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-701-929x628.avif 929w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-701-300x203.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-701-768x519.avif 768w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-701-400x271.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-701-800x541.avif 800w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-701-832x563.avif 832w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-701.avif 1004w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n    <meta charset=\"UTF-8\">\n    <meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n    <meta name=\"description\" content=\"Can AmerCable Tiger Brand Type W be interchanged with standard Type W portable power cable? Technical analysis by Anhui Feichun Special Cable.\">\n    <title>AmerCable Tiger Brand Type W Interchange Guide | Anhui Feichun Special Cable<\/title>\n    <style>\n        :root {\n            --bg-primary: #ffffff;\n            --bg-secondary: #f8f9fa;\n            --bg-table-header: #1e3a5f;\n            --text-primary: #1a202c;\n            --text-secondary: #4a5568;\n            --text-muted: #718096;\n            --border-color: #e2e8f0;\n            --accent-color: #c05621;\n            --accent-hover: #9c4221;\n            --table-stripe: #faf5f0;\n            --highlight-bg: rgba(192, 86, 33, 0.08);\n            --chinese-color: #6b7280;\n            --warning-bg: #fef3c7;\n            --warning-border: #f59e0b;\n            --success-bg: #d1fae5;\n            --success-border: #10b981;\n        }\n        @media (prefers-color-scheme: dark) {\n            :root {\n                --bg-primary: #1a202c;\n                --bg-secondary: #2d3748;\n                --bg-table-header: #2c4a6e;\n                --text-primary: #e2e8f0;\n                --text-secondary: #a0aec0;\n                --text-muted: #718096;\n                --border-color: #4a5568;\n                --accent-color: #ed8936;\n                --accent-hover: #fbd38d;\n                --table-stripe: #2d3748;\n                --highlight-bg: rgba(237, 137, 54, 0.15);\n                --chinese-color: #9ca3af;\n                --warning-bg: #44403c;\n                --warning-border: #f59e0b;\n                --success-bg: #1e3a2f;\n                --success-border: #10b981;\n            }\n        }\n        * { box-sizing: border-box; margin: 0; padding: 0; }\n        body {\n            font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, 'Helvetica Neue', Arial, sans-serif;\n            background-color: var(--bg-primary);\n            color: var(--text-primary);\n            line-height: 1.7;\n            transition: background-color 0.2s ease, color 0.2s ease;\n        }\n        .container { max-width: 960px; margin: 0 auto; padding: 40px 24px; }\n        header {\n            border-bottom: 3px solid var(--accent-color);\n            padding-bottom: 24px;\n            margin-bottom: 32px;\n        }\n        h1 {\n            font-size: 1.7rem;\n            font-weight: 700;\n            color: var(--text-primary);\n            margin-bottom: 8px;\n            line-height: 1.35;\n        }\n        .subtitle { font-size: 0.95rem; color: var(--text-secondary); }\n        .cn { color: var(--chinese-color); font-size: 0.88em; display: block; margin-top: 4px; }\n        h2 {\n            font-size: 1.25rem;\n            font-weight: 600;\n            color: var(--text-primary);\n            margin: 36px 0 16px 0;\n            padding-bottom: 8px;\n            border-bottom: 2px solid var(--border-color);\n        }\n        h3 { font-size: 1.05rem; font-weight: 600; color: var(--text-primary); margin: 24px 0 12px 0; }\n        p { margin-bottom: 16px; color: var(--text-secondary); text-align: justify; }\n        .table-container {\n            overflow-x: auto;\n            margin: 20px 0;\n            border: 1px solid var(--border-color);\n            border-radius: 6px;\n        }\n        table { width: 100%; border-collapse: collapse; font-size: 0.88rem; min-width: 580px; }\n        thead { background-color: var(--bg-table-header); }\n        th { color: #ffffff; font-weight: 600; text-align: left; padding: 12px 14px; white-space: nowrap; }\n        td { padding: 11px 14px; border-bottom: 1px solid var(--border-color); color: var(--text-secondary); }\n        tbody tr:nth-child(even) { background-color: var(--table-stripe); }\n        tbody tr:hover { background-color: var(--bg-secondary); }\n        .highlight-row { background-color: var(--highlight-bg) !important; }\n        .spec-label { font-weight: 600; color: var(--text-primary); min-width: 160px; }\n        a { color: var(--accent-color); text-decoration: none; transition: color 0.15s ease; }\n        a:hover { color: var(--accent-hover); text-decoration: underline; }\n        .source-list {\n            background-color: var(--bg-secondary);\n            padding: 18px 22px;\n            border-radius: 6px;\n            margin: 24px 0;\n            border-left: 4px solid var(--accent-color);\n        }\n        .source-list p { margin-bottom: 6px; font-size: 0.84rem; }\n        .source-list p:last-child { margin-bottom: 0; }\n        .alert-box {\n            padding: 16px 20px;\n            border-radius: 6px;\n            margin: 20px 0;\n            border-left: 4px solid;\n        }\n        .alert-warning { background-color: var(--warning-bg); border-color: var(--warning-border); }\n        .alert-success { background-color: var(--success-bg); border-color: var(--success-border); }\n        .alert-box strong { color: var(--text-primary); }\n        .badge {\n            display: inline-block;\n            padding: 4px 10px;\n            background-color: var(--accent-color);\n            color: #ffffff;\n            border-radius: 4px;\n            font-size: 0.75rem;\n            font-weight: 600;\n            text-transform: uppercase;\n            letter-spacing: 0.5px;\n        }\n        .comparison-header {\n            display: grid;\n            grid-template-columns: 1fr 1fr;\n            gap: 16px;\n            margin: 20px 0;\n        }\n        .comparison-card {\n            background-color: var(--bg-secondary);\n            padding: 16px;\n            border-radius: 6px;\n            border: 1px solid var(--border-color);\n        }\n        .comparison-card h4 {\n            font-size: 0.95rem;\n            color: var(--text-primary);\n            margin-bottom: 8px;\n            padding-bottom: 8px;\n            border-bottom: 1px solid var(--border-color);\n        }\n        .comparison-card p { font-size: 0.88rem; margin-bottom: 0; }\n        .contact-section {\n            background-color: var(--bg-secondary);\n            padding: 24px;\n            border-radius: 6px;\n            margin-top: 32px;\n        }\n        .contact-grid {\n            display: grid;\n            grid-template-columns: repeat(auto-fit, minmax(200px, 1fr));\n            gap: 14px;\n            margin-top: 16px;\n        }\n        .contact-item {\n            padding: 12px;\n            background-color: var(--bg-primary);\n            border-radius: 4px;\n            border: 1px solid var(--border-color);\n        }\n        .contact-label {\n            font-size: 0.78rem;\n            color: var(--text-muted);\n            text-transform: uppercase;\n            letter-spacing: 0.5px;\n            margin-bottom: 4px;\n        }\n        .contact-value { font-weight: 500; color: var(--text-primary); word-break: break-all; font-size: 0.92rem; }\n        footer {\n            margin-top: 48px;\n            padding-top: 24px;\n            border-top: 1px solid var(--border-color);\n            text-align: center;\n            color: var(--text-muted);\n            font-size: 0.84rem;\n        }\n        @media (max-width: 640px) {\n            .container { padding: 24px 16px; }\n            h1 { font-size: 1.35rem; }\n            .comparison-header { grid-template-columns: 1fr; }\n            th, td { padding: 9px 10px; }\n        }\n    <\/style>\n<\/head>\n<body>\n<div class=\"container\">\n    <header>\n        <span class=\"badge\">Technical Analysis<\/span>\n        <h1>AmerCable Tiger Brand: Can I Interchange AmerCable Tiger Brand Type W with Standard Type W Portable Power Cable?\n            <span class=\"cn\">AmerCable\u864e\u724c\u7535\u7f06\uff1a\u864e\u724cType W\u4e0e\u6807\u51c6Type W\u4fbf\u643a\u5f0f\u7535\u529b\u7535\u7f06\u53ef\u4ee5\u4e92\u6362\u4f7f\u7528\u5417\uff1f<\/span>\n        <\/h1>\n        <p class=\"subtitle\">Anhui Feichun Special Cable Co., Ltd. | \u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/p>\n    <\/header>\n\n    <article>\n        <h2>1. Understanding the Question <span class=\"cn\">\u7406\u89e3\u95ee\u9898<\/span><\/h2>\n        <p>This is one of the most frequently asked questions among mining engineers, industrial electricians, and procurement specialists working with portable power distribution systems. The short answer is: <strong>Yes, with important caveats<\/strong>. AmerCable Tiger Brand Type W cables can generally be interchanged with standard Type W cables in most applications, provided that the voltage rating, conductor size, and environmental conditions are properly matched. However, understanding the premium features of Tiger Brand helps determine whether a direct substitution maintains the same performance margins.<\/p>\n        <p class=\"cn\" style=\"font-size:0.9rem;\">\u8fd9\u662f\u77ff\u4e1a\u5de5\u7a0b\u5e08\u3001\u5de5\u4e1a\u7535\u6c14\u6280\u5e08\u548c\u91c7\u8d2d\u4e13\u5458\u5728\u4fbf\u643a\u5f0f\u914d\u7535\u7cfb\u7edf\u4e2d\u6700\u5e38\u95ee\u7684\u95ee\u9898\u4e4b\u4e00\u3002\u7b80\u77ed\u7684\u56de\u7b54\u662f\uff1a<strong>\u53ef\u4ee5\uff0c\u4f46\u6709\u91cd\u8981\u6ce8\u610f\u4e8b\u9879<\/strong>\u3002AmerCable\u864e\u724cType W\u7535\u7f06\u901a\u5e38\u53ef\u4ee5\u4e0e\u6807\u51c6Type W\u7535\u7f06\u4e92\u6362\u4f7f\u7528\uff0c\u524d\u63d0\u662f\u7535\u538b\u7b49\u7ea7\u3001\u5bfc\u4f53\u89c4\u683c\u548c\u73af\u5883\u6761\u4ef6\u6b63\u786e\u5339\u914d\u3002\u4f46\u4e86\u89e3\u864e\u724c\u7684\u9ad8\u7ea7\u7279\u6027\u6709\u52a9\u4e8e\u5224\u65ad\u76f4\u63a5\u66ff\u6362\u662f\u5426\u80fd\u4fdd\u6301\u76f8\u540c\u7684\u6027\u80fd\u4f59\u91cf\u3002<\/p>\n\n        <div class=\"comparison-header\">\n            <div class=\"comparison-card\">\n                <h4>AmerCable Tiger Brand Type W<\/h4>\n                <p>Premium-grade portable power cable with enhanced abrasion resistance, superior flexibility, and extended service life. Designed for the most demanding mining and industrial applications.<\/p>\n                <p class=\"cn\">\u9ad8\u7aef\u4fbf\u643a\u5f0f\u7535\u529b\u7535\u7f06\uff0c\u5177\u6709\u589e\u5f3a\u7684\u8010\u78e8\u6027\u3001\u4f18\u5f02\u7684\u67d4\u97e7\u6027\u548c\u66f4\u957f\u7684\u4f7f\u7528\u5bff\u547d\uff0c\u4e13\u4e3a\u6700\u4e25\u82db\u7684\u91c7\u77ff\u548c\u5de5\u4e1a\u5e94\u7528\u8bbe\u8ba1\u3002<\/p>\n            <\/div>\n            <div class=\"comparison-card\">\n                <h4>Standard Type W Cable<\/h4>\n                <p>Industry-standard portable power cable meeting minimum UL\/MSHA requirements for temporary power distribution in industrial, mining, and construction environments.<\/p>\n                <p class=\"cn\">\u7b26\u5408UL\/MSHA\u6700\u4f4e\u8981\u6c42\u7684\u884c\u4e1a\u6807\u51c6\u4fbf\u643a\u5f0f\u7535\u529b\u7535\u7f06\uff0c\u7528\u4e8e\u5de5\u4e1a\u3001\u91c7\u77ff\u548c\u5efa\u7b51\u73af\u5883\u4e2d\u7684\u4e34\u65f6\u914d\u7535\u3002<\/p>\n            <\/div>\n        <\/div>\n\n        <div class=\"source-list\">\n            <p><strong>Reference Sources \u53c2\u8003\u6765\u6e90:<\/strong><\/p>\n            <p>[1] AmerCable &#8211; Tiger Brand Product Line: <a href=\"https:\/\/www.amercable.com\/products\/tiger-brand\" target=\"_blank\" rel=\"nofollow noopener\">amercable.com\/products\/tiger-brand<\/a><\/p>\n            <p>[2] UL 1650 &#8211; Portable Power Cables Standard: <a href=\"https:\/\/www.ul.com\/resources\/ul-1650\" target=\"_blank\" rel=\"nofollow noopener\">ul.com\/resources\/ul-1650<\/a><\/p>\n        <\/div>\n\n        <h2>2. What is Type W Cable? <span class=\"cn\">\u4ec0\u4e48\u662fType W\u7535\u7f06\uff1f<\/span><\/h2>\n        <p>Type W (also designated as Type G-GC when containing ground-check conductors) is a classification of portable power cable defined by the U.S. National Electrical Code (NEC Article 400) and regulated by UL Standard 1650 and ICEA S-75-381. These cables are specifically engineered for temporary electrical connections where flexibility, durability, and resistance to physical abuse are paramount requirements.<\/p>\n        <p class=\"cn\" style=\"font-size:0.9rem;\">Type W\uff08\u5f53\u5305\u542b\u63a5\u5730\u68c0\u6d4b\u5bfc\u4f53\u65f6\u4e5f\u79f0\u4e3aType G-GC\uff09\u662f\u7531\u7f8e\u56fd\u56fd\u5bb6\u7535\u6c14\u89c4\u8303\uff08NEC\u7b2c400\u6761\uff09\u5b9a\u4e49\u3001\u5e76\u53d7UL 1650\u6807\u51c6\u548cICEA S-75-381\u89c4\u8303\u7684\u4fbf\u643a\u5f0f\u7535\u529b\u7535\u7f06\u5206\u7c7b\u3002\u8fd9\u4e9b\u7535\u7f06\u4e13\u4e3a\u4e34\u65f6\u7535\u6c14\u8fde\u63a5\u8bbe\u8ba1\uff0c\u5176\u4e2d\u67d4\u97e7\u6027\u3001\u8010\u4e45\u6027\u548c\u6297\u7269\u7406\u635f\u4f24\u662f\u9996\u8981\u8981\u6c42\u3002<\/p>\n\n        <p>The &#8220;W&#8221; designation indicates that the cable jacket is made from a thermoset compound (typically EPDM, CPE, or similar synthetic rubber) that provides resistance to sunlight, ozone, oils, and chemicals. This distinguishes Type W from thermoplastic-jacketed cables that may soften under high temperatures or prolonged UV exposure.<\/p>\n        <p class=\"cn\" style=\"font-size:0.9rem;\">&#8220;W&#8221;\u6807\u8bc6\u8868\u793a\u7535\u7f06\u62a4\u5957\u7531\u70ed\u56fa\u6027\u5316\u5408\u7269\uff08\u901a\u5e38\u4e3aEPDM\u3001CPE\u6216\u7c7b\u4f3c\u5408\u6210\u6a61\u80f6\uff09\u5236\u6210\uff0c\u5177\u6709\u8010\u9633\u5149\u3001\u81ed\u6c27\u3001\u6cb9\u7c7b\u548c\u5316\u5b66\u54c1\u6027\u80fd\u3002\u8fd9\u4f7fType W\u533a\u522b\u4e8e\u53ef\u80fd\u5728\u9ad8\u6e29\u6216\u957f\u671f\u7d2b\u5916\u7ebf\u7167\u5c04\u4e0b\u8f6f\u5316\u7684\u70ed\u5851\u6027\u62a4\u5957\u7535\u7f06\u3002<\/p>\n\n        <h3>2.1 Regulatory Framework \u6cd5\u89c4\u6846\u67b6<\/h3>\n        <div class=\"table-container\">\n            <table>\n                <thead>\n                    <tr>\n                        <th>Standard \u6807\u51c6<\/th>\n                        <th>Organization \u7ec4\u7ec7<\/th>\n                        <th>Scope \u8303\u56f4<\/th>\n                    <\/tr>\n                <\/thead>\n                <tbody>\n                    <tr>\n                        <td class=\"spec-label\">UL 1650<\/td>\n                        <td>Underwriters Laboratories<\/td>\n                        <td>Portable power cable construction, testing, listing<\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">ICEA S-75-381<\/td>\n                        <td>Insulated Cable Engineers Association<\/td>\n                        <td>Portable &#038; power feeder cables for mines<\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">MSHA 30 CFR Part 18<\/td>\n                        <td>Mine Safety &#038; Health Administration<\/td>\n                        <td>Permissibility for underground mining use<\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">NEC Article 400<\/td>\n                        <td>NFPA (National Fire Protection Association)<\/td>\n                        <td>Flexible cords and cables usage requirements<\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">CSA C22.2 No. 96<\/td>\n                        <td>Canadian Standards Association<\/td>\n                        <td>Portable power cables (Canadian market)<\/td>\n                    <\/tr>\n                <\/tbody>\n            <\/table>\n        <\/div>\n\n        <div class=\"source-list\">\n            <p><strong>Reference Sources \u53c2\u8003\u6765\u6e90:<\/strong><\/p>\n            <p>[3] MSHA 30 CFR Part 18 &#8211; Electrical Equipment: <a href=\"https:\/\/www.ecfr.gov\/current\/title-30\/chapter-I\/subchapter-B\/part-18\" target=\"_blank\" rel=\"nofollow noopener\">ecfr.gov<\/a><\/p>\n            <p>[4] ICEA S-75-381\/NEMA WC 58: <a href=\"https:\/\/www.icea.net\/standards\" target=\"_blank\" rel=\"nofollow noopener\">icea.net\/standards<\/a><\/p>\n            <p>[5] NEC Article 400 &#8211; Flexible Cords: <a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\" target=\"_blank\" rel=\"nofollow noopener\">nfpa.org<\/a><\/p>\n        <\/div>\n\n        <h2>3. AmerCable Tiger Brand: Premium Features <span class=\"cn\">AmerCable\u864e\u724c\uff1a\u9ad8\u7ea7\u7279\u6027<\/span><\/h2>\n        <p>AmerCable, now part of the Prysmian Group following the 2016 acquisition of General Cable (which had acquired AmerCable in 2011), has manufactured the Tiger Brand line since the 1970s. Tiger Brand cables have earned their reputation through consistent performance in the harshest mining environments, including underground coal mines, surface mining operations, and heavy industrial facilities.<\/p>\n        <p class=\"cn\" style=\"font-size:0.9rem;\">AmerCable\u81ea1970\u5e74\u4ee3\u5f00\u59cb\u751f\u4ea7\u864e\u724c\u7cfb\u5217\u7535\u7f06\uff0c\u73b0\u5df2\u6210\u4e3a\u666e\u777f\u53f8\u66fc\u96c6\u56e2\u7684\u4e00\u90e8\u5206\uff082016\u5e74\u666e\u777f\u53f8\u66fc\u6536\u8d2d\u4e86\u901a\u7528\u7535\u7f06\u516c\u53f8\uff0c\u540e\u8005\u4e8e2011\u5e74\u6536\u8d2d\u4e86AmerCable\uff09\u3002\u864e\u724c\u7535\u7f06\u56e0\u5728\u6700\u6076\u52a3\u7684\u91c7\u77ff\u73af\u5883\u4e2d\u8868\u73b0\u51fa\u8272\u800c\u8d62\u5f97\u58f0\u8a89\uff0c\u5305\u62ec\u5730\u4e0b\u7164\u77ff\u3001\u9732\u5929\u91c7\u77ff\u4f5c\u4e1a\u548c\u91cd\u578b\u5de5\u4e1a\u8bbe\u65bd\u3002<\/p>\n\n        <div class=\"alert-box alert-warning\">\n            <strong>Key Distinction \u5173\u952e\u533a\u522b:<\/strong> While both Tiger Brand and standard Type W cables meet the same minimum regulatory requirements (UL 1650, MSHA approval), Tiger Brand typically exceeds these minimums with proprietary compound formulations that deliver 30-50% longer service life under equivalent operating conditions.\n            <span class=\"cn\">\u867d\u7136\u864e\u724c\u548c\u6807\u51c6Type W\u7535\u7f06\u90fd\u6ee1\u8db3\u76f8\u540c\u7684\u6700\u4f4e\u6cd5\u89c4\u8981\u6c42\uff08UL 1650\u3001MSHA\u8ba4\u8bc1\uff09\uff0c\u4f46\u864e\u724c\u901a\u5e38\u901a\u8fc7\u4e13\u6709\u914d\u65b9\u8d85\u8d8a\u8fd9\u4e9b\u6700\u4f4e\u6807\u51c6\uff0c\u5728\u76f8\u540c\u64cd\u4f5c\u6761\u4ef6\u4e0b\u5ef6\u957f30-50%\u7684\u4f7f\u7528\u5bff\u547d\u3002<\/span>\n        <\/div>\n\n        <h3>3.1 Technical Specification Comparison \u6280\u672f\u89c4\u683c\u5bf9\u6bd4<\/h3>\n        <div class=\"table-container\">\n            <table>\n                <thead>\n                    <tr>\n                        <th>Parameter \u53c2\u6570<\/th>\n                        <th>Tiger Brand Type W<\/th>\n                        <th>Standard Type W<\/th>\n                        <th>Feichun FC-MW Series<\/th>\n                    <\/tr>\n                <\/thead>\n                <tbody>\n                    <tr>\n                        <td class=\"spec-label\">Conductor \u5bfc\u4f53<\/td>\n                        <td>Class K (30 AWG stranding)<\/td>\n                        <td>Class K per ASTM B172<\/td>\n                        <td>Class K \/ Class 5 (IEC)<\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">Insulation \u7edd\u7f18<\/td>\n                        <td>EPR (90\u00b0C rated)<\/td>\n                        <td>EPR (90\u00b0C rated)<\/td>\n                        <td>EPR\/HEPR (90\u00b0C\/105\u00b0C)<\/td>\n                    <\/tr>\n                    <tr class=\"highlight-row\">\n                        <td class=\"spec-label\">Jacket Compound \u62a4\u5957\u6750\u6599<\/td>\n                        <td>Proprietary CPE (Tiger-Flex\u2122)<\/td>\n                        <td>Standard CPE\/EPDM<\/td>\n                        <td>Premium CPE\/TPU hybrid<\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">Voltage Rating \u989d\u5b9a\u7535\u538b<\/td>\n                        <td>2kV \/ 5kV \/ 8kV \/ 15kV \/ 25kV<\/td>\n                        <td>2kV \/ 5kV \/ 8kV \/ 15kV \/ 25kV<\/td>\n                        <td>2kV \/ 5kV \/ 8kV \/ 15kV<\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">Temperature Range \u6e29\u5ea6\u8303\u56f4<\/td>\n                        <td>-50\u00b0C to +90\u00b0C<\/td>\n                        <td>-40\u00b0C to +90\u00b0C<\/td>\n                        <td>-50\u00b0C to +90\u00b0C<\/td>\n                    <\/tr>\n                    <tr class=\"highlight-row\">\n                        <td class=\"spec-label\">Abrasion Resistance \u8010\u78e8\u6027<\/td>\n                        <td>\u2265400 cycles (Taber test)<\/td>\n                        <td>\u2265250 cycles (typical)<\/td>\n                        <td>\u2265350 cycles (tested)<\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">Crush Resistance \u6297\u538b\u6027<\/td>\n                        <td>3,500 lbs\/in (enhanced)<\/td>\n                        <td>3,000 lbs\/in (standard)<\/td>\n                        <td>3,400 lbs\/in<\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">Oil Resistance \u8010\u6cb9\u6027<\/td>\n                        <td>Excellent (ASTM D471)<\/td>\n                        <td>Good (meets minimum)<\/td>\n                        <td>Excellent (ASTM D471)<\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">Flame Test \u963b\u71c3\u6d4b\u8bd5<\/td>\n                        <td>IEEE 1202 \/ UL 1685<\/td>\n                        <td>IEEE 1202<\/td>\n                        <td>IEEE 1202 \/ IEC 60332-3<\/td>\n                    <\/tr>\n                <\/tbody>\n            <\/table>\n        <\/div>\n\n        <div class=\"source-list\">\n            <p><strong>Reference Sources \u53c2\u8003\u6765\u6e90:<\/strong><\/p>\n            <p>[6] AmerCable Technical Handbook &#8211; Mining Cables: <a href=\"https:\/\/www.amercable.com\/resources\/technical-library\" target=\"_blank\" rel=\"nofollow noopener\">amercable.com\/resources<\/a><\/p>\n            <p>[7] ASTM B172 &#8211; Rope-Lay-Stranded Copper Conductors: <a href=\"https:\/\/www.astm.org\/b0172_b0172m-21.html\" target=\"_blank\" rel=\"nofollow noopener\">astm.org<\/a><\/p>\n            <p>[8] IEEE 1202 &#8211; Flame Testing of Cables: <a href=\"https:\/\/standards.ieee.org\/ieee\/1202\/3895\/\" target=\"_blank\" rel=\"nofollow noopener\">standards.ieee.org<\/a><\/p>\n        <\/div>\n\n        <h2>4. Interchangeability Analysis <span class=\"cn\">\u4e92\u6362\u6027\u5206\u6790<\/span><\/h2>\n        <p>When evaluating whether to substitute a Tiger Brand cable with a standard Type W or alternative equivalent, engineers should assess the following critical factors:<\/p>\n\n        <h3>4.1 When Direct Interchange is Acceptable \u53ef\u76f4\u63a5\u4e92\u6362\u7684\u60c5\u51b5<\/h3>\n        <div class=\"alert-box alert-success\">\n            <strong>\u2713 Safe to Interchange \u53ef\u5b89\u5168\u4e92\u6362:<\/strong>\n            <span class=\"cn\">\u5f53\u6ee1\u8db3\u4ee5\u4e0b\u6761\u4ef6\u65f6\u53ef\u5b89\u5168\u4e92\u6362\uff1a<\/span>\n            <p style=\"margin-top:10px;margin-bottom:0;\">Applications where standard Type W meets duty cycle requirements; environments without extreme abrasion, chemical exposure, or temperature extremes; installations with regular inspection and replacement schedules; cost-sensitive projects where premium longevity is not required.<\/p>\n        <\/div>\n\n        <h3>4.2 When Tiger Brand (or Equivalent Premium) is Recommended \u63a8\u8350\u4f7f\u7528\u864e\u724c\u6216\u540c\u7b49\u9ad8\u7aef\u4ea7\u54c1\u7684\u60c5\u51b5<\/h3>\n        <div class=\"alert-box alert-warning\">\n            <strong>\u26a0 Maintain Premium Grade \u4fdd\u6301\u9ad8\u7aef\u7b49\u7ea7:<\/strong>\n            <span class=\"cn\">\u5728\u4ee5\u4e0b\u60c5\u51b5\u4e0b\u5e94\u4fdd\u6301\u9ad8\u7aef\u7b49\u7ea7\uff1a<\/span>\n            <p style=\"margin-top:10px;margin-bottom:0;\">Underground mining per MSHA regulations where maximum safety margins are critical; continuous mining operations (longwall, continuous miner) with 24\/7 duty cycles; applications involving frequent cable movement, reeling, or drag chain systems; extreme temperature environments (below -40\u00b0C or high ambient heat); exposure to aggressive chemicals, hydraulic fluids, or cutting oils.<\/p>\n        <\/div>\n\n        <h3>4.3 Dimensional Compatibility \u5c3a\u5bf8\u517c\u5bb9\u6027<\/h3>\n        <div class=\"table-container\">\n            <table>\n                <thead>\n                    <tr>\n                        <th>Cable Size AWG\/kcmil<\/th>\n                        <th>Tiger Brand OD (typical)<\/th>\n                        <th>Standard Type W OD<\/th>\n                        <th>Feichun FC-MW OD<\/th>\n                    <\/tr>\n                <\/thead>\n                <tbody>\n                    <tr>\n                        <td class=\"spec-label\">3\/C #6 + 1\/C #8 Gnd<\/td>\n                        <td>1.05 in (26.7mm)<\/td>\n                        <td>1.00-1.10 in<\/td>\n                        <td>1.02 in (25.9mm)<\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">3\/C #4 + 1\/C #6 Gnd<\/td>\n                        <td>1.15 in (29.2mm)<\/td>\n                        <td>1.10-1.20 in<\/td>\n                        <td>1.12 in (28.4mm)<\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">3\/C #2 + 1\/C #4 Gnd<\/td>\n                        <td>1.30 in (33.0mm)<\/td>\n                        <td>1.25-1.35 in<\/td>\n                        <td>1.28 in (32.5mm)<\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">3\/C 4\/0 + 1\/C #2 Gnd<\/td>\n                        <td>2.10 in (53.3mm)<\/td>\n                        <td>2.00-2.15 in<\/td>\n                        <td>2.05 in (52.1mm)<\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">3\/C 350kcmil + 1\/C 1\/0 Gnd<\/td>\n                        <td>2.65 in (67.3mm)<\/td>\n                        <td>2.55-2.70 in<\/td>\n                        <td>2.60 in (66.0mm)<\/td>\n                    <\/tr>\n                <\/tbody>\n            <\/table>\n        <\/div>\n        <p><em>Note: Outside diameter (OD) tolerances typically \u00b15%. Verify connector and gland compatibility before substitution.<\/em><\/p>\n        <p class=\"cn\" style=\"font-size:0.85rem;\"><em>\u6ce8\uff1a\u5916\u5f84(OD)\u516c\u5dee\u901a\u5e38\u4e3a\u00b15%\u3002\u66ff\u6362\u524d\u8bf7\u9a8c\u8bc1\u8fde\u63a5\u5668\u548c\u7535\u7f06\u63a5\u5934\u7684\u517c\u5bb9\u6027\u3002<\/em><\/p>\n\n        <h2>5. Feichun FC-MW Series: Quality Alternative <span class=\"cn\">\u98de\u7eafFC-MW\u7cfb\u5217\uff1a\u4f18\u8d28\u66ff\u4ee3\u65b9\u6848<\/span><\/h2>\n        <p>Anhui Feichun Special Cable Co., Ltd. manufactures the <strong>FC-MW Series<\/strong> as a premium-grade alternative to both AmerCable Tiger Brand and standard Type W cables. These cables are engineered to match Tiger Brand performance characteristics while offering competitive pricing and responsive technical support for global mining and industrial customers.<\/p>\n        <p class=\"cn\" style=\"font-size:0.9rem;\">\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8\u751f\u4ea7\u7684<strong>FC-MW\u7cfb\u5217<\/strong>\u662fAmerCable\u864e\u724c\u548c\u6807\u51c6Type W\u7535\u7f06\u7684\u9ad8\u7aef\u66ff\u4ee3\u4ea7\u54c1\u3002\u8fd9\u4e9b\u7535\u7f06\u7684\u8bbe\u8ba1\u6027\u80fd\u4e0e\u864e\u724c\u76f8\u5f53\uff0c\u540c\u65f6\u4e3a\u5168\u7403\u77ff\u4e1a\u548c\u5de5\u4e1a\u5ba2\u6237\u63d0\u4f9b\u6709\u7ade\u4e89\u529b\u7684\u4ef7\u683c\u548c\u54cd\u5e94\u8fc5\u901f\u7684\u6280\u672f\u652f\u6301\u3002<\/p>\n\n        <h3>5.1 Application Scenarios \u5e94\u7528\u573a\u666f<\/h3>\n        <div class=\"table-container\">\n            <table>\n                <thead>\n                    <tr>\n                        <th>Application \u5e94\u7528<\/th>\n                        <th>Equipment \u8bbe\u5907<\/th>\n                        <th>Recommended Cable \u63a8\u8350\u7535\u7f06<\/th>\n                        <th>Voltage \u7535\u538b<\/th>\n                    <\/tr>\n                <\/thead>\n                <tbody>\n                    <tr>\n                        <td>Underground Coal Mining \u5730\u4e0b\u7164\u77ff<\/td>\n                        <td>Continuous Miner, Shuttle Car<\/td>\n                        <td>FC-MW-G-GC (with ground check)<\/td>\n                        <td>2kV \/ 5kV<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>Surface Mining \u9732\u5929\u91c7\u77ff<\/td>\n                        <td>Dragline, Electric Shovel<\/td>\n                        <td>FC-MW-SHD (Super Heavy Duty)<\/td>\n                        <td>8kV \/ 15kV<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>Oil &#038; Gas \u6cb9\u6c14\u884c\u4e1a<\/td>\n                        <td>Drilling Rig, Frac Pump<\/td>\n                        <td>FC-MW-OR (Oil Resistant)<\/td>\n                        <td>2kV \/ 5kV<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>Construction \u5efa\u7b51\u65bd\u5de5<\/td>\n                        <td>Portable Substation, Welder<\/td>\n                        <td>FC-MW Standard<\/td>\n                        <td>600V \/ 2kV<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>Entertainment \u6f14\u827a\u884c\u4e1a<\/td>\n                        <td>Stage Power, Temporary Events<\/td>\n                        <td>FC-MW-FX (Extra Flexible)<\/td>\n                        <td>600V<\/td>\n                    <\/tr>\n                <\/tbody>\n            <\/table>\n        <\/div>\n\n        <h3>5.2 Compliance &#038; Certifications \u5408\u89c4\u4e0e\u8ba4\u8bc1<\/h3>\n        <p>The Feichun FC-MW series is manufactured in accordance with international standards and can be supplied with third-party certifications for global market acceptance:<\/p>\n        <div class=\"table-container\">\n            <table>\n                <thead>\n                    <tr>\n                        <th>Certification \u8ba4\u8bc1<\/th>\n                        <th>Market \u5e02\u573a<\/th>\n                        <th>Status \u72b6\u6001<\/th>\n                    <\/tr>\n                <\/thead>\n                <tbody>\n                    <tr>\n                        <td class=\"spec-label\">UL Listed (UL 1650)<\/td>\n                        <td>USA \/ North America<\/td>\n                        <td>Available on request<\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">CSA Certified<\/td>\n                        <td>Canada<\/td>\n                        <td>Available on request<\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">MSHA Approved<\/td>\n                        <td>USA Mining<\/td>\n                        <td>Available on request<\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">CCC (China Compulsory)<\/td>\n                        <td>China<\/td>\n                        <td>Standard<\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">ISO 9001:2015<\/td>\n                        <td>International<\/td>\n                        <td>Certified<\/td>\n                    <\/tr>\n                <\/tbody>\n            <\/table>\n        <\/div>\n\n        <div class=\"source-list\">\n            <p><strong>Reference Sources \u53c2\u8003\u6765\u6e90:<\/strong><\/p>\n            <p>[9] UL Product iQ Database &#8211; Portable Power Cables: <a href=\"https:\/\/iq.ulprospector.com\" target=\"_blank\" rel=\"nofollow noopener\">iq.ulprospector.com<\/a><\/p>\n            <p>[10] MSHA Approved Equipment Listing: <a href=\"https:\/\/arlweb.msha.gov\/TECHSUPP\/ACC\/ACCHOME.HTM\" target=\"_blank\" rel=\"nofollow noopener\">msha.gov\/techsupp<\/a><\/p>\n            <p>[11] CSA Group &#8211; Industrial Cable Standards: <a href=\"https:\/\/www.csagroup.org\/standards\/areas-of-focus\/wire-and-cable\" target=\"_blank\" rel=\"nofollow noopener\">csagroup.org<\/a><\/p>\n        <\/div>\n\n        <h2>6. Conclusion <span class=\"cn\">\u7ed3\u8bba<\/span><\/h2>\n        <p>In summary, AmerCable Tiger Brand Type W and standard Type W cables are interchangeable from a regulatory compliance standpoint\u2014both meet UL 1650 and MSHA requirements for their respective voltage classes. The decision to interchange should be based on a thorough evaluation of the specific application&#8217;s mechanical demands, environmental conditions, and lifecycle cost considerations. For demanding applications where Tiger Brand&#8217;s premium characteristics are required, the Feichun FC-MW Series provides a cost-effective alternative that delivers comparable performance with the advantage of direct manufacturer support and competitive lead times.<\/p>\n        <p class=\"cn\" style=\"font-size:0.9rem;\">\u603b\u4e4b\uff0c\u4ece\u6cd5\u89c4\u5408\u89c4\u89d2\u5ea6\u800c\u8a00\uff0cAmerCable\u864e\u724cType W\u548c\u6807\u51c6Type W\u7535\u7f06\u53ef\u4ee5\u4e92\u6362\u2014\u2014\u4e24\u8005\u90fd\u6ee1\u8db3\u5404\u81ea\u7535\u538b\u7b49\u7ea7\u7684UL 1650\u548cMSHA\u8981\u6c42\u3002\u4e92\u6362\u51b3\u7b56\u5e94\u57fa\u4e8e\u5bf9\u5177\u4f53\u5e94\u7528\u7684\u673a\u68b0\u9700\u6c42\u3001\u73af\u5883\u6761\u4ef6\u548c\u751f\u547d\u5468\u671f\u6210\u672c\u7684\u5168\u9762\u8bc4\u4f30\u3002\u5bf9\u4e8e\u9700\u8981\u864e\u724c\u9ad8\u7aef\u7279\u6027\u7684\u4e25\u82db\u5e94\u7528\uff0c\u98de\u7eafFC-MW\u7cfb\u5217\u63d0\u4f9b\u4e86\u6027\u4ef7\u6bd4\u9ad8\u7684\u66ff\u4ee3\u65b9\u6848\uff0c\u5177\u6709\u76f8\u5f53\u7684\u6027\u80fd\uff0c\u540c\u65f6\u5177\u5907\u5236\u9020\u5546\u76f4\u63a5\u652f\u6301\u548c\u6709\u7ade\u4e89\u529b\u7684\u4ea4\u8d27\u671f\u4f18\u52bf\u3002<\/p>\n\n        <div class=\"contact-section\">\n            <h3>Contact Anhui Feichun Special Cable Co., Ltd. \u8054\u7cfb\u6211\u4eec<\/h3>\n            <p style=\"margin-top:8px;\">For technical consultation on Type W cable selection, quotation requests, or sample orders:<\/p>\n            <p class=\"cn\" style=\"font-size:0.9rem;\">\u5982\u9700Type W\u7535\u7f06\u9009\u578b\u6280\u672f\u54a8\u8be2\u3001\u62a5\u4ef7\u6216\u6837\u54c1\u8ba2\u8d2d\uff1a<\/p>\n            <div class=\"contact-grid\">\n                <div class=\"contact-item\">\n                    <div class=\"contact-label\">WhatsApp \u5fae\u4fe1\/\u7535\u8bdd<\/div>\n                    <div class=\"contact-value\">+86 138 5512 3218<\/div>\n                <\/div>\n                <div class=\"contact-item\">\n                    <div class=\"contact-label\">Technical Support \u6280\u672f\u652f\u6301<\/div>\n                    <div class=\"contact-value\"><a href=\"mailto:tech@feichuncables.com\" rel=\"nofollow\">tech@feichuncables.com<\/a><\/div>\n                <\/div>\n                <div class=\"contact-item\">\n                    <div class=\"contact-label\">Sales (Mr. Yang) \u9500\u552e\uff08\u6768\u5148\u751f\uff09<\/div>\n                    <div class=\"contact-value\"><a href=\"mailto:zihao.yang@feichuncables.com\" rel=\"nofollow\">zihao.yang@feichuncables.com<\/a><\/div>\n                <\/div>\n                <div class=\"contact-item\">\n                    <div class=\"contact-label\">Sales (Mr. Huang) \u9500\u552e\uff08\u9ec4\u5148\u751f\uff09<\/div>\n                    <div class=\"contact-value\"><a href=\"mailto:ziyu.huang@feichuncables.com\" rel=\"nofollow\">ziyu.huang@feichuncables.com<\/a><\/div>\n                <\/div>\n            <\/div>\n        <\/div>\n\n        <div class=\"source-list\" style=\"margin-top:32px;\">\n            <p><strong>Additional Industry References \u5176\u4ed6\u884c\u4e1a\u53c2\u8003:<\/strong><\/p>\n            <p>[12] Mining Cable Systems &#8211; General Cable Technical Guide: <a href=\"https:\/\/www.prysmiangroup.com\/en\/markets\/industrial\" target=\"_blank\" rel=\"nofollow noopener\">prysmiangroup.com\/markets\/industrial<\/a><\/p>\n            <p>[13] Southwire &#8211; Portable Cord &#038; Mining Cable Catalog: <a href=\"https:\/\/www.southwire.com\/wire-cable\/portable-cord-mining-cable\" target=\"_blank\" rel=\"nofollow noopener\">southwire.com<\/a><\/p>\n            <p>[14] National Mining Association &#8211; Electrical Safety Resources: <a href=\"https:\/\/nma.org\/safety-health\" target=\"_blank\" rel=\"nofollow noopener\">nma.org<\/a><\/p>\n        <\/div>\n    <\/article>\n\n    <footer>\n        <p>\u00a9 2024 Anhui Feichun Special Cable Co., Ltd. \u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/p>\n        <p style=\"margin-top:8px;\">This article is provided for informational purposes. All trademarks belong to their respective owners. AmerCable and Tiger Brand are registered trademarks of Prysmian Group.<\/p>\n    <\/footer>\n<\/div>\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"AmerCable, now part of the Prysmian Group following the 2016 acquisition of General Cable (which had acquired AmerCable in 2011), has manufactured the Tiger Brand line since the 1970s. Tiger Brand cables have earned their reputation through consistent performance in the harshest mining environments, including underground coal mines, surface mining operations, and heavy industrial facilities.\nAmerCable\u81ea1970\u5e74\u4ee3\u5f00\u59cb\u751f\u4ea7\u864e\u724c\u7cfb\u5217\u7535\u7f06\uff0c\u73b0\u5df2\u6210\u4e3a\u666e\u777f\u53f8\u66fc\u96c6\u56e2\u7684\u4e00\u90e8\u5206\uff082016\u5e74\u666e\u777f\u53f8\u66fc\u6536\u8d2d\u4e86\u901a\u7528\u7535\u7f06\u516c\u53f8\uff0c\u540e\u8005\u4e8e2011\u5e74\u6536\u8d2d\u4e86AmerCable\uff09\u3002\u864e\u724c\u7535\u7f06\u56e0\u5728\u6700\u6076\u52a3\u7684\u91c7\u77ff\u73af\u5883\u4e2d\u8868\u73b0\u51fa\u8272\u800c\u8d62\u5f97\u58f0\u8a89\uff0c\u5305\u62ec\u5730\u4e0b\u7164\u77ff\u3001\u9732\u5929\u91c7\u77ff\u4f5c\u4e1a\u548c\u91cd\u578b\u5de5\u4e1a\u8bbe\u65bd\u3002","protected":false},"author":1,"featured_media":5512,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[66,209],"tags":[38491,1925,4975,38482,38484,38492,38485,38481,3229,1946,38496,38489,3324,1114,1436,5090,16,4392,1958,38494,3320,171,38486,778,3946,152,107,176,18439,111,38487,139,214,204,1903,38495,38490,38488,28111,17,1913,4682,38493,1908,38497,38480,2143,1400,34045,38483,1091],"class_list":["post-5510","post","type-post","status-publish","format-standard","has-post-thumbnail","category-common-problems-encountered-in-cable-applications","category-icea-s-75-381-portable-power-cables","tag-15kv-trailing-cable","tag-2kv-mining-cable","tag-350-kcmil-mining-cable","tag-4-0-awg-portable-cable","tag-5kv-portable-power-cable","tag-8kv-mining-power-cable","tag-amercable-replacement-cable","tag-amercable-tiger-brand","tag-anhui-feichun-cable","tag-astm-b172-conductor","tag-china-type-w-cable-manufacturer","tag-class-k-stranded-conductor","tag-coal-mine-power-cable","tag-continuous-miner-cable","tag-cpe-jacket-cable","tag-csa-c22-2-no-96","tag-din-vde-0250","tag-dragline-trailing-cable","tag-electric-shovel-cable","tag-entertainment-power-cable","tag-epr-insulated-mining-cable","tag-explosion-proof-mining-cable","tag-fc-mw-mining-cable","tag-flexible-mining-cable","tag-ground-check-conductor-cable","tag-heavy-duty-mining-cable","tag-heavy-duty-e-loader-mining-cable","tag-icea-s-75-381-2","tag-ieee-1202-flame-test-cable","tag-mining-cable","tag-mining-cable-type-w","tag-mining-cables","tag-mining-power-cable","tag-mining-trailing-cable","tag-msha-approved-cable","tag-nec-article-400-cable","tag-oil-resistant-portable-cable","tag-portable-power-feeder-cable","tag-portable-substation-cable","tag-reeling-cable","tag-reeling-cable-mining","tag-shuttle-car-trailing-cable","tag-stage-power-distribution-cable","tag-surface-mining-cable","tag-tiger-brand-alternative","tag-tiger-brand-type-w-equivalent","tag-type-g-gc-cable","tag-type-w-cable","tag-type-w-portable-power-cable","tag-ul-1650-portable-cable","tag-underground-mining-cable","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/5510","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=5510"}],"version-history":[{"count":2,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/5510\/revisions"}],"predecessor-version":[{"id":5514,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/5510\/revisions\/5514"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/5512"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=5510"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=5510"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=5510"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}