{"id":5487,"date":"2026-01-30T11:28:49","date_gmt":"2026-01-30T03:28:49","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=5487"},"modified":"2026-01-30T11:28:53","modified_gmt":"2026-01-30T03:28:53","slug":"atlas-copco-boltec-feed-cable-selection-replacement-guide","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/atlas-copco-boltec-feed-cable-selection-replacement-guide\/","title":{"rendered":"Atlas Copco Boltec: Feed Cable Selection &#038; Replacement Guide"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Technical Specifications for Rock Bolting Rig Trailing Cables<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u963f\u7279\u62c9\u65af\u00b7\u79d1\u666e\u67ef Boltec \u951a\u6746\u94bb\u673a\uff1a\u9001\u8fdb\u7535\u7f06\u9009\u578b\u4e0e\u66f4\u6362\u6307\u5357 \u2014 \u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"3e3f3e\" data-has-transparency=\"false\" style=\"--dominant-color: #3e3f3e;\" loading=\"lazy\" decoding=\"async\" width=\"955\" height=\"620\" sizes=\"auto, (max-width: 955px) 100vw, 955px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-695.avif\" alt=\"\" class=\"wp-image-5488 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-695.avif 955w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-695-300x195.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-695-768x499.avif 768w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-695-400x260.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-695-800x519.avif 800w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-695-832x540.avif 832w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n    <meta charset=\"UTF-8\">\n    <meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n    <meta name=\"description\" content=\"Atlas Copco Boltec feed cable replacement guide. Professional mining cable selection for rock bolting rigs. Anhui Feichun Special Cable Co., Ltd.\">\n    <meta name=\"keywords\" content=\"Atlas Copco Boltec, feed cable, rock bolting rig, mining cable, EPR insulation, trailing cable, MSHA approved cable\">\n    <title>Atlas Copco Boltec Cable Selection Guide | Anhui Feichun Special Cable<\/title>\n    <style>\n        \/* CSS Variables for Light\/Dark Mode Compatibility *\/\n        :root {\n            --bg-primary: #f5f5f5;\n            --bg-secondary: #ffffff;\n            --bg-tertiary: #e8e8e8;\n            --text-primary: #1a1a1a;\n            --text-secondary: #4a4a4a;\n            --text-muted: #6b6b6b;\n            --accent-primary: #d35400;\n            --accent-secondary: #e67e22;\n            --border-color: #c0c0c0;\n            --table-header-bg: #2c3e50;\n            --table-header-text: #ffffff;\n            --table-row-alt: #f0f0f0;\n            --shadow-color: rgba(0,0,0,0.1);\n            --link-color: #2980b9;\n            --warning-bg: #fff3cd;\n            --warning-border: #ffc107;\n            --info-bg: #e7f3ff;\n            --info-border: #2196f3;\n        }\n\n        @media (prefers-color-scheme: dark) {\n            :root {\n                --bg-primary: #1a1a1a;\n                --bg-secondary: #252525;\n                --bg-tertiary: #2d2d2d;\n                --text-primary: #e8e8e8;\n                --text-secondary: #b8b8b8;\n                --text-muted: #888888;\n                --accent-primary: #e67e22;\n                --accent-secondary: #f39c12;\n                --border-color: #444444;\n                --table-header-bg: #34495e;\n                --table-header-text: #ecf0f1;\n                --table-row-alt: #2a2a2a;\n                --shadow-color: rgba(0,0,0,0.3);\n                --link-color: #5dade2;\n                --warning-bg: #3d3520;\n                --warning-border: #d4a017;\n                --info-bg: #1a2a3a;\n                --info-border: #1976d2;\n            }\n        }\n\n        \/* Reset and Base Styles *\/\n        *, *::before, *::after {\n            box-sizing: border-box;\n            margin: 0;\n            padding: 0;\n        }\n\n        html {\n            font-size: 16px;\n            scroll-behavior: smooth;\n        }\n\n        body {\n            font-family: 'Segoe UI', 'Helvetica Neue', Arial, sans-serif;\n            background-color: var(--bg-primary);\n            color: var(--text-primary);\n            line-height: 1.7;\n            min-height: 100vh;\n        }\n\n        \/* Full-Width Container *\/\n        .container {\n            width: 100%;\n            max-width: 1200px;\n            margin: 0 auto;\n            padding: 0 24px;\n        }\n\n        \/* Header Section *\/\n        .header {\n            background: linear-gradient(135deg, var(--table-header-bg) 0%, #1a252f 100%);\n            color: var(--table-header-text);\n            padding: 40px 0;\n            border-bottom: 4px solid var(--accent-primary);\n        }\n\n        .header-content {\n            display: flex;\n            flex-direction: column;\n            gap: 16px;\n        }\n\n        .company-badge {\n            display: inline-block;\n            background: var(--accent-primary);\n            color: #fff;\n            padding: 6px 16px;\n            font-size: 0.85rem;\n            font-weight: 600;\n            letter-spacing: 0.5px;\n            text-transform: uppercase;\n        }\n\n        .header h1 {\n            font-size: 1.9rem;\n            font-weight: 700;\n            line-height: 1.3;\n            margin: 8px 0;\n        }\n\n        .header-subtitle {\n            font-size: 1rem;\n            opacity: 0.9;\n            color: #b8c5d1;\n        }\n\n        .header-cn {\n            font-size: 0.95rem;\n            opacity: 0.85;\n            border-left: 3px solid var(--accent-primary);\n            padding-left: 12px;\n            margin-top: 8px;\n        }\n\n        \/* Main Content *\/\n        .main-content {\n            padding: 40px 0;\n        }\n\n        \/* Article Sections *\/\n        .article-section {\n            background: var(--bg-secondary);\n            border: 1px solid var(--border-color);\n            margin-bottom: 24px;\n            box-shadow: 0 2px 8px var(--shadow-color);\n        }\n\n        .section-header {\n            background: var(--bg-tertiary);\n            padding: 16px 24px;\n            border-bottom: 1px solid var(--border-color);\n            display: flex;\n            align-items: center;\n            gap: 12px;\n        }\n\n        .section-number {\n            background: var(--accent-primary);\n            color: #fff;\n            width: 32px;\n            height: 32px;\n            display: flex;\n            align-items: center;\n            justify-content: center;\n            font-weight: 700;\n            font-size: 0.9rem;\n        }\n\n        .section-header h2 {\n            font-size: 1.25rem;\n            font-weight: 600;\n            color: var(--text-primary);\n        }\n\n        .section-body {\n            padding: 24px;\n        }\n\n        .section-body p {\n            margin-bottom: 16px;\n            color: var(--text-secondary);\n        }\n\n        .cn-note {\n            font-size: 0.9rem;\n            color: var(--text-muted);\n            background: var(--bg-tertiary);\n            padding: 12px 16px;\n            border-left: 3px solid var(--accent-secondary);\n            margin: 16px 0;\n        }\n\n        \/* Professional Tables *\/\n        .table-wrapper {\n            overflow-x: auto;\n            margin: 20px 0;\n        }\n\n        table {\n            width: 100%;\n            border-collapse: collapse;\n            font-size: 0.9rem;\n        }\n\n        thead {\n            background: var(--table-header-bg);\n            color: var(--table-header-text);\n        }\n\n        th {\n            padding: 14px 16px;\n            text-align: left;\n            font-weight: 600;\n            text-transform: uppercase;\n            font-size: 0.8rem;\n            letter-spacing: 0.5px;\n            border-bottom: 2px solid var(--accent-primary);\n        }\n\n        td {\n            padding: 12px 16px;\n            border-bottom: 1px solid var(--border-color);\n            color: var(--text-secondary);\n        }\n\n        tbody tr:nth-child(even) {\n            background: var(--table-row-alt);\n        }\n\n        tbody tr:hover {\n            background: var(--bg-tertiary);\n        }\n\n        .spec-value {\n            font-family: 'Consolas', 'Monaco', monospace;\n            color: var(--accent-primary);\n            font-weight: 600;\n        }\n\n        \/* Info Boxes *\/\n        .info-box {\n            background: var(--info-bg);\n            border-left: 4px solid var(--info-border);\n            padding: 16px 20px;\n            margin: 20px 0;\n        }\n\n        .warning-box {\n            background: var(--warning-bg);\n            border-left: 4px solid var(--warning-border);\n            padding: 16px 20px;\n            margin: 20px 0;\n        }\n\n        .box-title {\n            font-weight: 600;\n            margin-bottom: 8px;\n            color: var(--text-primary);\n        }\n\n        \/* Parameter Cards *\/\n        .param-grid {\n            display: grid;\n            grid-template-columns: repeat(auto-fit, minmax(280px, 1fr));\n            gap: 16px;\n            margin: 20px 0;\n        }\n\n        .param-card {\n            background: var(--bg-tertiary);\n            border: 1px solid var(--border-color);\n            padding: 16px;\n        }\n\n        .param-label {\n            font-size: 0.8rem;\n            text-transform: uppercase;\n            letter-spacing: 0.5px;\n            color: var(--text-muted);\n            margin-bottom: 6px;\n        }\n\n        .param-value {\n            font-size: 1.4rem;\n            font-weight: 700;\n            color: var(--accent-primary);\n        }\n\n        .param-unit {\n            font-size: 0.85rem;\n            font-weight: 400;\n            color: var(--text-muted);\n        }\n\n        .param-note {\n            font-size: 0.8rem;\n            color: var(--text-muted);\n            margin-top: 4px;\n        }\n\n        \/* External Links *\/\n        .source-link {\n            color: var(--link-color);\n            text-decoration: none;\n            border-bottom: 1px dotted var(--link-color);\n        }\n\n        .source-link:hover {\n            border-bottom-style: solid;\n        }\n\n        \/* References Section *\/\n        .references {\n            background: var(--bg-tertiary);\n            padding: 20px 24px;\n            margin-top: 20px;\n        }\n\n        .references h3 {\n            font-size: 1rem;\n            margin-bottom: 12px;\n            color: var(--text-primary);\n        }\n\n        .ref-list {\n            list-style: none;\n        }\n\n        .ref-list li {\n            padding: 8px 0;\n            border-bottom: 1px solid var(--border-color);\n            font-size: 0.85rem;\n            color: var(--text-muted);\n        }\n\n        .ref-list li:last-child {\n            border-bottom: none;\n        }\n\n        .ref-number {\n            display: inline-block;\n            background: var(--text-muted);\n            color: var(--bg-secondary);\n            width: 20px;\n            height: 20px;\n            text-align: center;\n            line-height: 20px;\n            font-size: 0.75rem;\n            margin-right: 8px;\n        }\n\n        \/* Contact Section *\/\n        .contact-section {\n            background: linear-gradient(135deg, var(--table-header-bg) 0%, #1a252f 100%);\n            color: #fff;\n            padding: 40px 0;\n            margin-top: 40px;\n        }\n\n        .contact-grid {\n            display: grid;\n            grid-template-columns: repeat(auto-fit, minmax(250px, 1fr));\n            gap: 24px;\n        }\n\n        .contact-card {\n            background: rgba(255,255,255,0.05);\n            border: 1px solid rgba(255,255,255,0.1);\n            padding: 20px;\n        }\n\n        .contact-card h3 {\n            font-size: 0.85rem;\n            text-transform: uppercase;\n            letter-spacing: 0.5px;\n            opacity: 0.8;\n            margin-bottom: 8px;\n        }\n\n        .contact-value {\n            font-size: 1rem;\n            color: #fff;\n        }\n\n        .contact-value a {\n            color: var(--accent-secondary);\n            text-decoration: none;\n        }\n\n        .contact-value a:hover {\n            text-decoration: underline;\n        }\n\n        .whatsapp-badge {\n            display: inline-flex;\n            align-items: center;\n            gap: 8px;\n            background: #25D366;\n            color: #fff;\n            padding: 8px 16px;\n            margin-top: 8px;\n            font-weight: 600;\n        }\n\n        \/* Footer *\/\n        .footer {\n            background: var(--bg-secondary);\n            border-top: 1px solid var(--border-color);\n            padding: 24px 0;\n            text-align: center;\n        }\n\n        .footer p {\n            font-size: 0.85rem;\n            color: var(--text-muted);\n        }\n\n        \/* Responsive *\/\n        @media (max-width: 768px) {\n            .header h1 {\n                font-size: 1.5rem;\n            }\n            \n            .container {\n                padding: 0 16px;\n            }\n            \n            .section-body {\n                padding: 16px;\n            }\n            \n            th, td {\n                padding: 10px 12px;\n            }\n        }\n\n        \/* Print Styles *\/\n        @media print {\n            .header, .contact-section {\n                background: #2c3e50 !important;\n                -webkit-print-color-adjust: exact;\n                print-color-adjust: exact;\n            }\n        }\n    <\/style>\n<\/head>\n<body>\n    <!-- Header -->\n    <header class=\"header\">\n        <div class=\"container\">\n            <div class=\"header-content\">\n                <span class=\"company-badge\">Anhui Feichun Special Cable Co., Ltd.<\/span>\n                <h1>Atlas Copco Boltec: Feed Cable Selection &amp; Replacement Guide<\/h1>\n                <p class=\"header-subtitle\">Technical Specifications for Rock Bolting Rig Trailing Cables<\/p>\n                <p class=\"header-cn\">\u963f\u7279\u62c9\u65af\u00b7\u79d1\u666e\u67ef Boltec \u951a\u6746\u94bb\u673a\uff1a\u9001\u8fdb\u7535\u7f06\u9009\u578b\u4e0e\u66f4\u6362\u6307\u5357 \u2014 \u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/p>\n            <\/div>\n        <\/div>\n    <\/header>\n\n    <!-- Main Content -->\n    <main class=\"main-content\">\n        <div class=\"container\">\n            \n            <!-- Section 1: Introduction -->\n            <article class=\"article-section\">\n                <div class=\"section-header\">\n                    <span class=\"section-number\">01<\/span>\n                    <h2>Introduction to Atlas Copco Boltec Series \u4ecb\u7ecd<\/h2>\n                <\/div>\n                <div class=\"section-body\">\n                    <p>The Atlas Copco Boltec series represents a range of mechanized rock bolting rigs designed for underground mining and tunneling operations. These machines are engineered to install rock bolts efficiently in challenging subterranean environments, requiring robust electrical systems capable of withstanding extreme mechanical stress, moisture exposure, and continuous operational demands.<\/p>\n                    \n                    <div class=\"cn-note\">\n                        \u963f\u7279\u62c9\u65af\u00b7\u79d1\u666e\u67ef Boltec \u7cfb\u5217\u662f\u4e13\u4e3a\u5730\u4e0b\u91c7\u77ff\u548c\u96a7\u9053\u4f5c\u4e1a\u8bbe\u8ba1\u7684\u673a\u68b0\u5316\u951a\u6746\u94bb\u673a\u3002\u8fd9\u4e9b\u8bbe\u5907\u5728\u6076\u52a3\u7684\u5730\u4e0b\u73af\u5883\u4e2d\u9ad8\u6548\u5b89\u88c5\u951a\u6746\uff0c\u5176\u7535\u6c14\u7cfb\u7edf\u9700\u8981\u627f\u53d7\u6781\u7aef\u673a\u68b0\u5e94\u529b\u3001\u6f6e\u6e7f\u73af\u5883\u548c\u6301\u7eed\u8fd0\u884c\u7684\u8003\u9a8c\u3002\n                    <\/div>\n                    \n                    <p>The feed cable (also referred to as the trailing cable or reeling cable) is a critical component that delivers electrical power from the mine&#8217;s distribution system to the rig&#8217;s onboard systems. When replacing an aging or damaged feed cable on older Boltec models, proper cable selection ensures operational safety, regulatory compliance, and optimal machine performance.<\/p>\n                    \n                    <div class=\"cn-note\">\n                        \u9001\u8fdb\u7535\u7f06\uff08\u4e5f\u79f0\u4e3a\u62d6\u66f3\u7535\u7f06\u6216\u5377\u7b52\u7535\u7f06\uff09\u662f\u5c06\u7535\u529b\u4ece\u77ff\u4e95\u914d\u7535\u7cfb\u7edf\u4f20\u8f93\u5230\u94bb\u673a\u673a\u8f7d\u7cfb\u7edf\u7684\u5173\u952e\u90e8\u4ef6\u3002\u5728\u66f4\u6362\u8001\u65e7 Boltec \u673a\u578b\u4e0a\u635f\u574f\u7684\u9001\u8fdb\u7535\u7f06\u65f6\uff0c\u6b63\u786e\u7684\u7535\u7f06\u9009\u578b\u53ef\u786e\u4fdd\u8fd0\u884c\u5b89\u5168\u3001\u7b26\u5408\u6cd5\u89c4\u8981\u6c42\u5e76\u4f18\u5316\u8bbe\u5907\u6027\u80fd\u3002\n                    <\/div>\n\n                    <div class=\"info-box\">\n                        <div class=\"box-title\">Application Scope \u9002\u7528\u8303\u56f4<\/div>\n                        <p>This guide covers cable replacement considerations for Boltec models including Boltec 235, Boltec MC, Boltec S, and legacy Boltec units operating in underground hard rock mining environments.<\/p>\n                    <\/div>\n                <\/div>\n            <\/article>\n\n            <!-- Section 2: Technical Requirements -->\n            <article class=\"article-section\">\n                <div class=\"section-header\">\n                    <span class=\"section-number\">02<\/span>\n                    <h2>Technical Requirements &amp; Specifications \u6280\u672f\u8981\u6c42\u4e0e\u89c4\u683c<\/h2>\n                <\/div>\n                <div class=\"section-body\">\n                    <p>Feed cables for rock bolting equipment must meet stringent performance criteria defined by international mining safety standards. The following parameters represent typical requirements for Boltec-compatible trailing cables based on industry standards and OEM specifications.<\/p>\n                    \n                    <div class=\"cn-note\">\n                        \u951a\u6746\u94bb\u673a\u7528\u9001\u8fdb\u7535\u7f06\u5fc5\u987b\u6ee1\u8db3\u56fd\u9645\u77ff\u5c71\u5b89\u5168\u6807\u51c6\u89c4\u5b9a\u7684\u4e25\u683c\u6027\u80fd\u6807\u51c6\u3002\u4ee5\u4e0b\u53c2\u6570\u4ee3\u8868\u57fa\u4e8e\u884c\u4e1a\u6807\u51c6\u548c\u539f\u59cb\u8bbe\u5907\u5236\u9020\u5546\u89c4\u683c\u7684 Boltec \u517c\u5bb9\u62d6\u66f3\u7535\u7f06\u7684\u5178\u578b\u8981\u6c42\u3002\n                    <\/div>\n\n                    <div class=\"param-grid\">\n                        <div class=\"param-card\">\n                            <div class=\"param-label\">Rated Voltage \u989d\u5b9a\u7535\u538b<\/div>\n                            <div class=\"param-value\">0.6\/1 <span class=\"param-unit\">kV<\/span><\/div>\n                            <div class=\"param-note\">Suitable for 380-690V systems \/ \u9002\u7528\u4e8e380-690V\u7cfb\u7edf<\/div>\n                        <\/div>\n                        <div class=\"param-card\">\n                            <div class=\"param-label\">Conductor Cross-Section \u5bfc\u4f53\u622a\u9762<\/div>\n                            <div class=\"param-value\">3\u00d750+1\u00d725 <span class=\"param-unit\">mm\u00b2<\/span><\/div>\n                            <div class=\"param-note\">Typical configuration \/ \u5178\u578b\u914d\u7f6e<\/div>\n                        <\/div>\n                        <div class=\"param-card\">\n                            <div class=\"param-label\">Insulation Material \u7edd\u7f18\u6750\u6599<\/div>\n                            <div class=\"param-value\">EPR\/HEPR<\/div>\n                            <div class=\"param-note\">Ethylene Propylene Rubber \/ \u4e59\u4e19\u6a61\u80f6<\/div>\n                        <\/div>\n                        <div class=\"param-card\">\n                            <div class=\"param-label\">Sheath Material \u62a4\u5957\u6750\u6599<\/div>\n                            <div class=\"param-value\">CPE\/CSP<\/div>\n                            <div class=\"param-note\">Chlorinated Polyethylene \/ \u6c2f\u5316\u805a\u4e59\u70ef<\/div>\n                        <\/div>\n                        <div class=\"param-card\">\n                            <div class=\"param-label\">Operating Temperature \u5de5\u4f5c\u6e29\u5ea6<\/div>\n                            <div class=\"param-value\">-40 ~ +90 <span class=\"param-unit\">\u00b0C<\/span><\/div>\n                            <div class=\"param-note\">Extended range available \/ \u53ef\u63d0\u4f9b\u6269\u5c55\u8303\u56f4<\/div>\n                        <\/div>\n                        <div class=\"param-card\">\n                            <div class=\"param-label\">Minimum Bending Radius \u6700\u5c0f\u5f2f\u66f2\u534a\u5f84<\/div>\n                            <div class=\"param-value\">6\u00d7OD<\/div>\n                            <div class=\"param-note\">Dynamic operation \/ \u52a8\u6001\u8fd0\u884c<\/div>\n                        <\/div>\n                    <\/div>\n\n                    <h3 style=\"margin: 24px 0 16px; font-size: 1.1rem;\">Recommended Cable Specifications \u63a8\u8350\u7535\u7f06\u89c4\u683c<\/h3>\n                    \n                    <div class=\"table-wrapper\">\n                        <table>\n                            <thead>\n                                <tr>\n                                    <th>Parameter \u53c2\u6570<\/th>\n                                    <th>Specification \u89c4\u683c<\/th>\n                                    <th>Standard Reference \u6807\u51c6\u53c2\u8003<\/th>\n                                <\/tr>\n                            <\/thead>\n                            <tbody>\n                                <tr>\n                                    <td>Cable Type \u7535\u7f06\u7c7b\u578b<\/td>\n                                    <td><span class=\"spec-value\">Type G-GC \/ Type SHD-GC<\/span><\/td>\n                                    <td>ICEA S-75-381 \/ NEMA WC 58<sup>[1]<\/sup><\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>Voltage Rating \u7535\u538b\u7b49\u7ea7<\/td>\n                                    <td><span class=\"spec-value\">2kV (2000V)<\/span><\/td>\n                                    <td>MSHA 30 CFR Part 18<sup>[2]<\/sup><\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>Conductor \u5bfc\u4f53<\/td>\n                                    <td><span class=\"spec-value\">Class K Flexible Stranded Copper<\/span><\/td>\n                                    <td>IEC 60228<sup>[3]<\/sup><\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>Insulation \u7edd\u7f18\u5c42<\/td>\n                                    <td><span class=\"spec-value\">EPR (90\u00b0C rated)<\/span><\/td>\n                                    <td>IEC 60502-1<sup>[4]<\/sup><\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>Ground Check Conductor \u63a5\u5730\u68c0\u6d4b\u5bfc\u4f53<\/td>\n                                    <td><span class=\"spec-value\">Required for mobile equipment<\/span><\/td>\n                                    <td>AS\/NZS 1802<sup>[5]<\/sup><\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>Flame Retardancy \u963b\u71c3\u6027<\/td>\n                                    <td><span class=\"spec-value\">IEC 60332-1-2 Compliant<\/span><\/td>\n                                    <td>IEC 60332<sup>[6]<\/sup><\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>Oil Resistance \u8010\u6cb9\u6027<\/td>\n                                    <td><span class=\"spec-value\">MSHA Approved<\/span><\/td>\n                                    <td>30 CFR \u00a718.64<sup>[2]<\/sup><\/td>\n                                <\/tr>\n                            <\/tbody>\n                        <\/table>\n                    <\/div>\n\n                    <div class=\"warning-box\">\n                        <div class=\"box-title\">\u26a0 Critical Note \u91cd\u8981\u63d0\u793a<\/div>\n                        <p>Always verify specific cable requirements with your Atlas Copco service representative and local mining regulatory authority before procurement. Cable specifications may vary based on regional standards (MSHA, AS\/NZS, EN) and site-specific electrical system configurations.<\/p>\n                        <p style=\"margin-top: 8px; font-size: 0.9rem; color: var(--text-muted);\">\u5728\u91c7\u8d2d\u524d\uff0c\u52a1\u5fc5\u4e0e\u963f\u7279\u62c9\u65af\u00b7\u79d1\u666e\u67ef\u670d\u52a1\u4ee3\u8868\u548c\u5f53\u5730\u77ff\u5c71\u76d1\u7ba1\u673a\u6784\u6838\u5b9e\u5177\u4f53\u7535\u7f06\u8981\u6c42\u3002\u7535\u7f06\u89c4\u683c\u53ef\u80fd\u56e0\u533a\u57df\u6807\u51c6\uff08MSHA\u3001AS\/NZS\u3001EN\uff09\u548c\u73b0\u573a\u7535\u6c14\u7cfb\u7edf\u914d\u7f6e\u800c\u5f02\u3002<\/p>\n                    <\/div>\n                <\/div>\n            <\/article>\n\n            <!-- Section 3: Cable Construction -->\n            <article class=\"article-section\">\n                <div class=\"section-header\">\n                    <span class=\"section-number\">03<\/span>\n                    <h2>Cable Construction for Mining Applications \u77ff\u7528\u7535\u7f06\u7ed3\u6784<\/h2>\n                <\/div>\n                <div class=\"section-body\">\n                    <p>Mining trailing cables for equipment like the Boltec require specialized construction to endure the rigors of underground operation. The multi-layer design provides mechanical protection, electrical safety, and operational flexibility essential for mobile mining machinery.<\/p>\n                    \n                    <div class=\"cn-note\">\n                        Boltec \u7b49\u8bbe\u5907\u4f7f\u7528\u7684\u77ff\u7528\u62d6\u66f3\u7535\u7f06\u9700\u8981\u7279\u6b8a\u7ed3\u6784\u4ee5\u627f\u53d7\u5730\u4e0b\u4f5c\u4e1a\u7684\u4e25\u82db\u6761\u4ef6\u3002\u591a\u5c42\u8bbe\u8ba1\u4e3a\u79fb\u52a8\u5f0f\u91c7\u77ff\u673a\u68b0\u63d0\u4f9b\u5fc5\u8981\u7684\u673a\u68b0\u4fdd\u62a4\u3001\u7535\u6c14\u5b89\u5168\u548c\u64cd\u4f5c\u7075\u6d3b\u6027\u3002\n                    <\/div>\n\n                    <div class=\"table-wrapper\">\n                        <table>\n                            <thead>\n                                <tr>\n                                    <th>Layer \u5c42\u6b21<\/th>\n                                    <th>Component \u7ec4\u4ef6<\/th>\n                                    <th>Function \u529f\u80fd<\/th>\n                                    <th>Material \u6750\u6599<\/th>\n                                <\/tr>\n                            <\/thead>\n                            <tbody>\n                                <tr>\n                                    <td>1<\/td>\n                                    <td>Power Conductors \u7535\u529b\u5bfc\u4f53<\/td>\n                                    <td>Current transmission \u7535\u6d41\u4f20\u8f93<\/td>\n                                    <td><span class=\"spec-value\">Annealed copper, Class K<\/span><\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>2<\/td>\n                                    <td>Conductor Insulation \u5bfc\u4f53\u7edd\u7f18<\/td>\n                                    <td>Electrical isolation \u7535\u6c14\u9694\u79bb<\/td>\n                                    <td><span class=\"spec-value\">EPR\/HEPR compound<\/span><\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>3<\/td>\n                                    <td>Ground Conductor(s) \u63a5\u5730\u5bfc\u4f53<\/td>\n                                    <td>Protective earthing \u4fdd\u62a4\u63a5\u5730<\/td>\n                                    <td><span class=\"spec-value\">Stranded copper<\/span><\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>4<\/td>\n                                    <td>Ground Check Conductor \u63a5\u5730\u68c0\u6d4b\u5bfc\u4f53<\/td>\n                                    <td>Ground continuity monitoring \u63a5\u5730\u8fde\u7eed\u6027\u76d1\u6d4b<\/td>\n                                    <td><span class=\"spec-value\">Insulated copper pilot<\/span><\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>5<\/td>\n                                    <td>Filler\/Bedding \u586b\u5145\u5c42<\/td>\n                                    <td>Round profile, flexibility \u5706\u5f62\u5916\u5f62\uff0c\u67d4\u97e7\u6027<\/td>\n                                    <td><span class=\"spec-value\">Non-hygroscopic compound<\/span><\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>6<\/td>\n                                    <td>Outer Sheath \u5916\u62a4\u5957<\/td>\n                                    <td>Mechanical\/chemical protection \u673a\u68b0\/\u5316\u5b66\u4fdd\u62a4<\/td>\n                                    <td><span class=\"spec-value\">CPE\/CSP heavy-duty<\/span><\/td>\n                                <\/tr>\n                            <\/tbody>\n                        <\/table>\n                    <\/div>\n\n                    <h3 style=\"margin: 24px 0 16px; font-size: 1.1rem;\">Common Conductor Configurations for Boltec Rigs Boltec\u94bb\u673a\u5e38\u7528\u5bfc\u4f53\u914d\u7f6e<\/h3>\n                    \n                    <div class=\"table-wrapper\">\n                        <table>\n                            <thead>\n                                <tr>\n                                    <th>Configuration \u914d\u7f6e<\/th>\n                                    <th>Power (mm\u00b2) \u7535\u6e90<\/th>\n                                    <th>Earth (mm\u00b2) \u63a5\u5730<\/th>\n                                    <th>Pilot \u68c0\u6d4b\u7ebf<\/th>\n                                    <th>Typical Application \u5178\u578b\u5e94\u7528<\/th>\n                                <\/tr>\n                            <\/thead>\n                            <tbody>\n                                <tr>\n                                    <td>Standard \u6807\u51c6\u578b<\/td>\n                                    <td><span class=\"spec-value\">3\u00d735<\/span><\/td>\n                                    <td><span class=\"spec-value\">1\u00d716<\/span><\/td>\n                                    <td>3\u00d72.5<\/td>\n                                    <td>Boltec S, smaller units<\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>Medium \u4e2d\u578b<\/td>\n                                    <td><span class=\"spec-value\">3\u00d750<\/span><\/td>\n                                    <td><span class=\"spec-value\">1\u00d725<\/span><\/td>\n                                    <td>3\u00d72.5<\/td>\n                                    <td>Boltec MC, Boltec 235<\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>Heavy-Duty \u91cd\u578b<\/td>\n                                    <td><span class=\"spec-value\">3\u00d770<\/span><\/td>\n                                    <td><span class=\"spec-value\">1\u00d735<\/span><\/td>\n                                    <td>3\u00d74<\/td>\n                                    <td>High-power configurations<\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>Extended Length \u52a0\u957f\u578b<\/td>\n                                    <td><span class=\"spec-value\">3\u00d795<\/span><\/td>\n                                    <td><span class=\"spec-value\">1\u00d750<\/span><\/td>\n                                    <td>3\u00d74<\/td>\n                                    <td>Long trailing distances<\/td>\n                                <\/tr>\n                            <\/tbody>\n                        <\/table>\n                    <\/div>\n                <\/div>\n            <\/article>\n\n            <!-- Section 4: Selection Criteria -->\n            <article class=\"article-section\">\n                <div class=\"section-header\">\n                    <span class=\"section-number\">04<\/span>\n                    <h2>Cable Selection Criteria \u7535\u7f06\u9009\u578b\u6807\u51c6<\/h2>\n                <\/div>\n                <div class=\"section-body\">\n                    <p>Selecting the appropriate replacement cable requires systematic evaluation of electrical, mechanical, and environmental factors. The following criteria should guide the selection process for older Atlas Copco Boltec installations.<\/p>\n                    \n                    <div class=\"cn-note\">\n                        \u9009\u62e9\u5408\u9002\u7684\u66ff\u6362\u7535\u7f06\u9700\u8981\u7cfb\u7edf\u8bc4\u4f30\u7535\u6c14\u3001\u673a\u68b0\u548c\u73af\u5883\u56e0\u7d20\u3002\u4ee5\u4e0b\u6807\u51c6\u53ef\u6307\u5bfc\u8001\u65e7\u963f\u7279\u62c9\u65af\u00b7\u79d1\u666e\u67ef Boltec \u8bbe\u5907\u7684\u9009\u578b\u8fc7\u7a0b\u3002\n                    <\/div>\n\n                    <div class=\"table-wrapper\">\n                        <table>\n                            <thead>\n                                <tr>\n                                    <th>Criterion \u6807\u51c6<\/th>\n                                    <th>Consideration \u8003\u8651\u56e0\u7d20<\/th>\n                                    <th>Recommendation \u5efa\u8bae<\/th>\n                                <\/tr>\n                            <\/thead>\n                            <tbody>\n                                <tr>\n                                    <td><strong>Voltage Drop \u7535\u538b\u964d<\/strong><\/td>\n                                    <td>Cable length, load current, power factor<\/td>\n                                    <td>Maintain &lt;5% at full load per IEEE Std 141<sup>[7]<\/sup><\/td>\n                                <\/tr>\n                                <tr>\n                                    <td><strong>Current Capacity \u8f7d\u6d41\u91cf<\/strong><\/td>\n                                    <td>Motor FLA, starting current, ambient temp<\/td>\n                                    <td>Size for 125% of equipment rated current<\/td>\n                                <\/tr>\n                                <tr>\n                                    <td><strong>Mechanical Durability \u673a\u68b0\u8010\u4e45\u6027<\/strong><\/td>\n                                    <td>Drag, crush, flexing cycles<\/td>\n                                    <td>Heavy-duty CPE sheath, min. 2.5mm thickness<\/td>\n                                <\/tr>\n                                <tr>\n                                    <td><strong>Environmental Resistance \u73af\u5883\u8010\u53d7\u6027<\/strong><\/td>\n                                    <td>Water, oil, UV, chemical exposure<\/td>\n                                    <td>CSP\/CPE sheath, MSHA flame test compliant<\/td>\n                                <\/tr>\n                                <tr>\n                                    <td><strong>Flexibility \u67d4\u97e7\u6027<\/strong><\/td>\n                                    <td>Reel operation, routing constraints<\/td>\n                                    <td>Class K conductors, rubber compounds<\/td>\n                                <\/tr>\n                                <tr>\n                                    <td><strong>Ground Fault Protection \u63a5\u5730\u6545\u969c\u4fdd\u62a4<\/strong><\/td>\n                                    <td>Pilot wire requirements, GFR compatibility<\/td>\n                                    <td>Ground check conductor per local code<\/td>\n                                <\/tr>\n                            <\/tbody>\n                        <\/table>\n                    <\/div>\n\n                    <div class=\"info-box\">\n                        <div class=\"box-title\">Voltage Drop Calculation Formula \u7535\u538b\u964d\u8ba1\u7b97\u516c\u5f0f<\/div>\n                        <p style=\"font-family: 'Consolas', monospace; background: var(--bg-tertiary); padding: 12px; margin-top: 8px;\">\n                            V<sub>drop<\/sub> = (\u221a3 \u00d7 I \u00d7 L \u00d7 (R\u00b7cos\u03c6 + X\u00b7sin\u03c6)) \/ 1000\n                        <\/p>\n                        <p style=\"font-size: 0.85rem; margin-top: 8px;\">Where: I = current (A), L = length (m), R = resistance (\u03a9\/km), X = reactance (\u03a9\/km), cos\u03c6 = power factor<\/p>\n                    <\/div>\n                <\/div>\n            <\/article>\n\n            <!-- Section 5: Installation Considerations -->\n            <article class=\"article-section\">\n                <div class=\"section-header\">\n                    <span class=\"section-number\">05<\/span>\n                    <h2>Installation &amp; Safety Considerations \u5b89\u88c5\u4e0e\u5b89\u5168\u6ce8\u610f\u4e8b\u9879<\/h2>\n                <\/div>\n                <div class=\"section-body\">\n                    <p>Proper cable installation is critical for safe operation and longevity. Underground mining environments present unique challenges that must be addressed through careful installation practices aligned with applicable safety regulations.<\/p>\n                    \n                    <div class=\"cn-note\">\n                        \u6b63\u786e\u7684\u7535\u7f06\u5b89\u88c5\u5bf9\u4e8e\u5b89\u5168\u8fd0\u884c\u548c\u4f7f\u7528\u5bff\u547d\u81f3\u5173\u91cd\u8981\u3002\u5730\u4e0b\u91c7\u77ff\u73af\u5883\u5e26\u6765\u72ec\u7279\u6311\u6218\uff0c\u5fc5\u987b\u901a\u8fc7\u7b26\u5408\u9002\u7528\u5b89\u5168\u6cd5\u89c4\u7684\u8c28\u614e\u5b89\u88c5\u5b9e\u8df5\u6765\u89e3\u51b3\u3002\n                    <\/div>\n\n                    <div class=\"table-wrapper\">\n                        <table>\n                            <thead>\n                                <tr>\n                                    <th>Aspect \u65b9\u9762<\/th>\n                                    <th>Requirement \u8981\u6c42<\/th>\n                                    <th>Reference \u53c2\u8003<\/th>\n                                <\/tr>\n                            <\/thead>\n                            <tbody>\n                                <tr>\n                                    <td>Cable Termination \u7535\u7f06\u7aef\u63a5<\/td>\n                                    <td>Use approved mining connectors, proper strain relief<\/td>\n                                    <td>MSHA 30 CFR \u00a718.35<sup>[2]<\/sup><\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>Reel Tensioning \u5377\u7b52\u5f20\u529b<\/td>\n                                    <td>Maintain proper tension to prevent damage<\/td>\n                                    <td>OEM specifications<\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>Ground Continuity Testing \u63a5\u5730\u8fde\u7eed\u6027\u6d4b\u8bd5<\/td>\n                                    <td>Verify before energizing, periodic testing<\/td>\n                                    <td>AS\/NZS 4871.1<sup>[8]<\/sup><\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>Insulation Resistance \u7edd\u7f18\u7535\u963b<\/td>\n                                    <td>Minimum 1M\u03a9 at 500V DC for new installations<\/td>\n                                    <td>IEC 60364-6<sup>[9]<\/sup><\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>Visual Inspection \u76ee\u89c6\u68c0\u67e5<\/td>\n                                    <td>Daily pre-shift inspection for damage<\/td>\n                                    <td>Mine site safety protocols<\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>Cable Storage \u7535\u7f06\u5b58\u653e<\/td>\n                                    <td>Protect from UV, chemicals, mechanical damage<\/td>\n                                    <td>Manufacturer guidelines<\/td>\n                                <\/tr>\n                            <\/tbody>\n                        <\/table>\n                    <\/div>\n\n                    <div class=\"warning-box\">\n                        <div class=\"box-title\">\u26a0 Safety Warning \u5b89\u5168\u8b66\u544a<\/div>\n                        <p>All electrical work on mining equipment must be performed by qualified personnel in accordance with applicable mining electrical safety regulations. De-energize, lock out, and tag out equipment before commencing cable replacement work. Verify zero energy state before handling conductors.<\/p>\n                        <p style=\"margin-top: 8px; font-size: 0.9rem; color: var(--text-muted);\">\u6240\u6709\u91c7\u77ff\u8bbe\u5907\u7684\u7535\u6c14\u5de5\u4f5c\u5fc5\u987b\u7531\u5408\u683c\u4eba\u5458\u6309\u7167\u9002\u7528\u7684\u91c7\u77ff\u7535\u6c14\u5b89\u5168\u6cd5\u89c4\u8fdb\u884c\u3002\u5728\u5f00\u59cb\u7535\u7f06\u66f4\u6362\u5de5\u4f5c\u524d\uff0c\u5fc5\u987b\u65ad\u7535\u3001\u9501\u5b9a\u5e76\u6302\u724c\u3002\u5728\u63a5\u89e6\u5bfc\u4f53\u524d\uff0c\u786e\u8ba4\u96f6\u80fd\u91cf\u72b6\u6001\u3002<\/p>\n                    <\/div>\n                <\/div>\n            <\/article>\n\n            <!-- Section 6: Applicable Standards -->\n            <article class=\"article-section\">\n                <div class=\"section-header\">\n                    <span class=\"section-number\">06<\/span>\n                    <h2>Applicable Standards &amp; Regulations \u9002\u7528\u6807\u51c6\u4e0e\u6cd5\u89c4<\/h2>\n                <\/div>\n                <div class=\"section-body\">\n                    <p>Mining cable selection and installation must comply with regional regulatory frameworks. The following table summarizes key standards applicable to underground mining trailing cables in major mining jurisdictions.<\/p>\n                    \n                    <div class=\"cn-note\">\n                        \u77ff\u7528\u7535\u7f06\u9009\u578b\u548c\u5b89\u88c5\u5fc5\u987b\u7b26\u5408\u533a\u57df\u6cd5\u89c4\u6846\u67b6\u3002\u4e0b\u8868\u603b\u7ed3\u4e86\u4e3b\u8981\u91c7\u77ff\u7ba1\u8f96\u533a\u5730\u4e0b\u91c7\u77ff\u62d6\u66f3\u7535\u7f06\u9002\u7528\u7684\u5173\u952e\u6807\u51c6\u3002\n                    <\/div>\n\n                    <div class=\"table-wrapper\">\n                        <table>\n                            <thead>\n                                <tr>\n                                    <th>Region \u5730\u533a<\/th>\n                                    <th>Standard \u6807\u51c6<\/th>\n                                    <th>Description \u63cf\u8ff0<\/th>\n                                    <th>External Reference \u5916\u90e8\u53c2\u8003<\/th>\n                                <\/tr>\n                            <\/thead>\n                            <tbody>\n                                <tr>\n                                    <td>USA<\/td>\n                                    <td>30 CFR Part 18<\/td>\n                                    <td>MSHA electrical equipment standards<\/td>\n                                    <td><a href=\"https:\/\/www.ecfr.gov\/current\/title-30\/chapter-I\/subchapter-B\/part-18\" rel=\"nofollow noopener\" target=\"_blank\" class=\"source-link\">eCFR Title 30<\/a><\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>USA<\/td>\n                                    <td>ICEA S-75-381<\/td>\n                                    <td>Portable mining cable standards<\/td>\n                                    <td><a href=\"https:\/\/www.icea.net\/\" rel=\"nofollow noopener\" target=\"_blank\" class=\"source-link\">ICEA Official<\/a><\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>Australia\/NZ<\/td>\n                                    <td>AS\/NZS 1802<\/td>\n                                    <td>Electric cables &#8211; trailing cables<\/td>\n                                    <td><a href=\"https:\/\/www.standards.org.au\/\" rel=\"nofollow noopener\" target=\"_blank\" class=\"source-link\">Standards Australia<\/a><\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>Australia<\/td>\n                                    <td>AS\/NZS 4871.1<\/td>\n                                    <td>Electrical equipment for mines<\/td>\n                                    <td><a href=\"https:\/\/www.standards.org.au\/\" rel=\"nofollow noopener\" target=\"_blank\" class=\"source-link\">Standards Australia<\/a><\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>International<\/td>\n                                    <td>IEC 60502-1<\/td>\n                                    <td>Power cables 1kV to 30kV<\/td>\n                                    <td><a href=\"https:\/\/www.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\" class=\"source-link\">IEC Webstore<\/a><\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>International<\/td>\n                                    <td>IEC 60228<\/td>\n                                    <td>Conductors for insulated cables<\/td>\n                                    <td><a href=\"https:\/\/www.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\" class=\"source-link\">IEC Webstore<\/a><\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>International<\/td>\n                                    <td>IEC 60332<\/td>\n                                    <td>Fire performance for cables<\/td>\n                                    <td><a href=\"https:\/\/www.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\" class=\"source-link\">IEC Webstore<\/a><\/td>\n                                <\/tr>\n                                <tr>\n                                    <td>China \u4e2d\u56fd<\/td>\n                                    <td>MT 818<\/td>\n                                    <td>Coal mine rubber cables (\u7164\u77ff\u7528\u6a61\u5957\u7535\u7f06)<\/td>\n                                    <td><a href=\"https:\/\/www.samr.gov.cn\/\" rel=\"nofollow noopener\" target=\"_blank\" class=\"source-link\">SAMR China<\/a><\/td>\n                                <\/tr>\n                            <\/tbody>\n                        <\/table>\n                    <\/div>\n                <\/div>\n            <\/article>\n\n            <!-- Section 7: Why Choose Feichun -->\n            <article class=\"article-section\">\n                <div class=\"section-header\">\n                    <span class=\"section-number\">07<\/span>\n                    <h2>Anhui Feichun Special Cable Solutions \u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u89e3\u51b3\u65b9\u6848<\/h2>\n                <\/div>\n                <div class=\"section-body\">\n                    <p>Anhui Feichun Special Cable Co., Ltd. (\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8) manufactures high-performance mining and industrial cables designed to meet international standards. Our product range includes trailing cables suitable for replacement applications on Atlas Copco Boltec and similar underground mining equipment.<\/p>\n                    \n                    <div class=\"cn-note\">\n                        \u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8\u751f\u4ea7\u7b26\u5408\u56fd\u9645\u6807\u51c6\u7684\u9ad8\u6027\u80fd\u77ff\u7528\u548c\u5de5\u4e1a\u7535\u7f06\u3002\u6211\u4eec\u7684\u4ea7\u54c1\u7cfb\u5217\u5305\u62ec\u9002\u7528\u4e8e\u963f\u7279\u62c9\u65af\u00b7\u79d1\u666e\u67ef Boltec \u53ca\u7c7b\u4f3c\u5730\u4e0b\u91c7\u77ff\u8bbe\u5907\u66ff\u6362\u5e94\u7528\u7684\u62d6\u66f3\u7535\u7f06\u3002\n                    <\/div>\n\n                    <div class=\"table-wrapper\">\n                        <table>\n                            <thead>\n                                <tr>\n                                    <th>Product Series \u4ea7\u54c1\u7cfb\u5217<\/th>\n                                    <th>Specifications \u89c4\u683c<\/th>\n                                    <th>Applications \u5e94\u7528<\/th>\n                                <\/tr>\n                            <\/thead>\n                            <tbody>\n                                <tr>\n                                    <td><strong>Mining Trailing Cable \u77ff\u7528\u62d6\u66f3\u7535\u7f06<\/strong><\/td>\n                                    <td>0.66\/1.14kV, 3\u00d716~3\u00d7150mm\u00b2, EPR\/CPE<\/td>\n                                    <td>Rock bolting rigs, shuttle cars, continuous miners<\/td>\n                                <\/tr>\n                                <tr>\n                                    <td><strong>Flexible Rubber Cable \u67d4\u6027\u6a61\u5957\u7535\u7f06<\/strong><\/td>\n                                    <td>0.38\/0.66kV, 3\u00d74~3\u00d795mm\u00b2, rubber sheath<\/td>\n                                    <td>Mobile mining equipment, drill rigs<\/td>\n                                <\/tr>\n                                <tr>\n                                    <td><strong>Reeling Cable \u5377\u7b52\u7535\u7f06<\/strong><\/td>\n                                    <td>0.6\/1kV, enhanced flexibility, high flex cycles<\/td>\n                                    <td>Cable reel systems, cranes, stackers<\/td>\n                                <\/tr>\n                                <tr>\n                                    <td><strong>Shield Cable \u5c4f\u853d\u7535\u7f06<\/strong><\/td>\n                                    <td>Braided copper screen, EMI protection<\/td>\n                                    <td>VFD applications, sensitive equipment<\/td>\n                                <\/tr>\n                            <\/tbody>\n                        <\/table>\n                    <\/div>\n\n                    <div class=\"info-box\">\n                        <div class=\"box-title\">Custom Manufacturing \u5b9a\u5236\u751f\u4ea7<\/div>\n                        <p>Feichun offers custom cable manufacturing to match OEM specifications for legacy equipment. Contact our technical team with your existing cable specifications or equipment model for a tailored replacement solution.<\/p>\n                        <p style=\"font-size: 0.9rem; margin-top: 8px; color: var(--text-muted);\">\u98de\u7eaf\u63d0\u4f9b\u5b9a\u5236\u7535\u7f06\u751f\u4ea7\uff0c\u4ee5\u5339\u914d\u65e7\u8bbe\u5907\u7684\u539f\u59cb\u8bbe\u5907\u5236\u9020\u5546\u89c4\u683c\u3002\u8bf7\u8054\u7cfb\u6211\u4eec\u7684\u6280\u672f\u56e2\u961f\uff0c\u63d0\u4f9b\u60a8\u73b0\u6709\u7684\u7535\u7f06\u89c4\u683c\u6216\u8bbe\u5907\u578b\u53f7\uff0c\u4ee5\u83b7\u53d6\u91cf\u8eab\u5b9a\u5236\u7684\u66ff\u6362\u89e3\u51b3\u65b9\u6848\u3002<\/p>\n                    <\/div>\n                <\/div>\n            <\/article>\n\n            <!-- References Section -->\n            <div class=\"references\">\n                <h3>References &amp; Sources \u53c2\u8003\u6587\u732e\u4e0e\u6765\u6e90<\/h3>\n                <ul class=\"ref-list\">\n                    <li><span class=\"ref-number\">1<\/span>ICEA S-75-381\/NEMA WC 58 &#8211; Portable and Power Feeder Cables for Use in Mines and Similar Applications. <a href=\"https:\/\/www.icea.net\/\" rel=\"nofollow noopener\" target=\"_blank\" class=\"source-link\">ICEA<\/a><\/li>\n                    <li><span class=\"ref-number\">2<\/span>U.S. Code of Federal Regulations, Title 30, Part 18 &#8211; Electric Motor-Driven Mine Equipment and Accessories. <a href=\"https:\/\/www.ecfr.gov\/current\/title-30\/chapter-I\/subchapter-B\/part-18\" rel=\"nofollow noopener\" target=\"_blank\" class=\"source-link\">eCFR<\/a><\/li>\n                    <li><span class=\"ref-number\">3<\/span>IEC 60228:2004 &#8211; Conductors of insulated cables. <a href=\"https:\/\/webstore.iec.ch\/publication\/1065\" rel=\"nofollow noopener\" target=\"_blank\" class=\"source-link\">IEC Webstore<\/a><\/li>\n                    <li><span class=\"ref-number\">4<\/span>IEC 60502-1 &#8211; Power cables with extruded insulation and their accessories. <a href=\"https:\/\/webstore.iec.ch\/publication\/2270\" rel=\"nofollow noopener\" target=\"_blank\" class=\"source-link\">IEC Webstore<\/a><\/li>\n                    <li><span class=\"ref-number\">5<\/span>AS\/NZS 1802 &#8211; Electric cables &#8211; Reeling and trailing &#8211; For underground mining. <a href=\"https:\/\/www.standards.org.au\/\" rel=\"nofollow noopener\" target=\"_blank\" class=\"source-link\">Standards Australia<\/a><\/li>\n                    <li><span class=\"ref-number\">6<\/span>IEC 60332 &#8211; Tests on electric and optical fibre cables under fire conditions. <a href=\"https:\/\/webstore.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\" class=\"source-link\">IEC Webstore<\/a><\/li>\n                    <li><span class=\"ref-number\">7<\/span>IEEE Std 141 (Red Book) &#8211; Recommended Practice for Electric Power Distribution for Industrial Plants. <a href=\"https:\/\/standards.ieee.org\/\" rel=\"nofollow noopener\" target=\"_blank\" class=\"source-link\">IEEE SA<\/a><\/li>\n                    <li><span class=\"ref-number\">8<\/span>AS\/NZS 4871.1 &#8211; Electrical equipment for mines and quarries. <a href=\"https:\/\/www.standards.org.au\/\" rel=\"nofollow noopener\" target=\"_blank\" class=\"source-link\">Standards Australia<\/a><\/li>\n                    <li><span class=\"ref-number\">9<\/span>IEC 60364-6 &#8211; Low-voltage electrical installations &#8211; Verification. <a href=\"https:\/\/webstore.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\" class=\"source-link\">IEC Webstore<\/a><\/li>\n                    <li><span class=\"ref-number\">10<\/span>Atlas Copco Underground Rock Excavation &#8211; Product Documentation. <a href=\"https:\/\/www.atlascopco.com\/\" rel=\"nofollow noopener\" target=\"_blank\" class=\"source-link\">Atlas Copco<\/a><\/li>\n                <\/ul>\n            <\/div>\n\n        <\/div>\n    <\/main>\n\n    <!-- Contact Section -->\n    <section class=\"contact-section\">\n        <div class=\"container\">\n            <h2 style=\"font-size: 1.5rem; margin-bottom: 24px; font-weight: 600;\">Contact Anhui Feichun Special Cable \u8054\u7cfb\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06<\/h2>\n            <div class=\"contact-grid\">\n                <div class=\"contact-card\">\n                    <h3>Technical Inquiries \u6280\u672f\u54a8\u8be2<\/h3>\n                    <div class=\"contact-value\">\n                        <a href=\"mailto:tech@feichuncables.com\" rel=\"nofollow noopener\">tech@feichuncables.com<\/a>\n                    <\/div>\n                <\/div>\n                <div class=\"contact-card\">\n                    <h3>Sales &#8211; Zihao Yang \u9500\u552e &#8211; \u6768\u5b50\u8c6a<\/h3>\n                    <div class=\"contact-value\">\n                        <a href=\"mailto:zihao.yang@feichuncables.com\" rel=\"nofollow noopener\">zihao.yang@feichuncables.com<\/a>\n                    <\/div>\n                <\/div>\n                <div class=\"contact-card\">\n                    <h3>Sales &#8211; Ziyu Huang \u9500\u552e &#8211; \u9ec4\u5b50\u7389<\/h3>\n                    <div class=\"contact-value\">\n                        <a href=\"mailto:ziyu.huang@feichuncables.com\" rel=\"nofollow noopener\">ziyu.huang@feichuncables.com<\/a>\n                    <\/div>\n                <\/div>\n                <div class=\"contact-card\">\n                    <h3>WhatsApp \/ \u5fae\u4fe1<\/h3>\n                    <div class=\"contact-value\">\n                        <span class=\"whatsapp-badge\">\n                            <svg width=\"20\" height=\"20\" viewBox=\"0 0 24 24\" fill=\"currentColor\"><path d=\"M17.472 14.382c-.297-.149-1.758-.867-2.03-.967-.273-.099-.471-.148-.67.15-.197.297-.767.966-.94 1.164-.173.199-.347.223-.644.075-.297-.15-1.255-.463-2.39-1.475-.883-.788-1.48-1.761-1.653-2.059-.173-.297-.018-.458.13-.606.134-.133.298-.347.446-.52.149-.174.198-.298.298-.497.099-.198.05-.371-.025-.52-.075-.149-.669-1.612-.916-2.207-.242-.579-.487-.5-.669-.51-.173-.008-.371-.01-.57-.01-.198 0-.52.074-.792.372-.272.297-1.04 1.016-1.04 2.479 0 1.462 1.065 2.875 1.213 3.074.149.198 2.096 3.2 5.077 4.487.709.306 1.262.489 1.694.625.712.227 1.36.195 1.871.118.571-.085 1.758-.719 2.006-1.413.248-.694.248-1.289.173-1.413-.074-.124-.272-.198-.57-.347m-5.421 7.403h-.004a9.87 9.87 0 01-5.031-1.378l-.361-.214-3.741.982.998-3.648-.235-.374a9.86 9.86 0 01-1.51-5.26c.001-5.45 4.436-9.884 9.888-9.884 2.64 0 5.122 1.03 6.988 2.898a9.825 9.825 0 012.893 6.994c-.003 5.45-4.437 9.884-9.885 9.884m8.413-18.297A11.815 11.815 0 0012.05 0C5.495 0 .16 5.335.157 11.892c0 2.096.547 4.142 1.588 5.945L.057 24l6.305-1.654a11.882 11.882 0 005.683 1.448h.005c6.554 0 11.89-5.335 11.893-11.893a11.821 11.821 0 00-3.48-8.413z\"\/><\/svg>\n                            +86 13855123218\n                        <\/span>\n                    <\/div>\n                <\/div>\n            <\/div>\n        <\/div>\n    <\/section>\n\n    <!-- Footer -->\n    <footer class=\"footer\">\n        <div class=\"container\">\n            <p><strong>Anhui Feichun Special Cable Co., Ltd.<\/strong> | \u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/p>\n            <p style=\"margin-top: 8px;\">Professional Mining &amp; Industrial Cable Manufacturer | \u4e13\u4e1a\u77ff\u7528\u53ca\u5de5\u4e1a\u7535\u7f06\u5236\u9020\u5546<\/p>\n            <p style=\"margin-top: 16px; font-size: 0.8rem;\">\u00a9 2024 Anhui Feichun Special Cable Co., Ltd. All technical specifications are subject to confirmation. \u6240\u6709\u6280\u672f\u89c4\u683c\u4ee5\u786e\u8ba4\u4e3a\u51c6\u3002<\/p>\n        <\/div>\n    <\/footer>\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"The Atlas Copco Boltec series represents a range of mechanized rock bolting rigs designed for underground mining and tunneling operations. These machines are engineered to install rock bolts efficiently in challenging subterranean environments, requiring robust electrical systems capable of withstanding extreme mechanical stress, moisture exposure, and continuous operational demands.\n\u963f\u7279\u62c9\u65af\u00b7\u79d1\u666e\u67ef Boltec \u7cfb\u5217\u662f\u4e13\u4e3a\u5730\u4e0b\u91c7\u77ff\u548c\u96a7\u9053\u4f5c\u4e1a\u8bbe\u8ba1\u7684\u673a\u68b0\u5316\u951a\u6746\u94bb\u673a\u3002\u8fd9\u4e9b\u8bbe\u5907\u5728\u6076\u52a3\u7684\u5730\u4e0b\u73af\u5883\u4e2d\u9ad8\u6548\u5b89\u88c5\u951a\u6746\uff0c\u5176\u7535\u6c14\u7cfb\u7edf\u9700\u8981\u627f\u53d7\u6781\u7aef\u673a\u68b0\u5e94\u529b\u3001\u6f6e\u6e7f\u73af\u5883\u548c\u6301\u7eed\u8fd0\u884c\u7684\u8003\u9a8c\u3002","protected":false},"author":1,"featured_media":5488,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[46,94,9563,1,56],"tags":[11634,38251,3229,27116,38244,38250,38245,38247,38261,2538,1114,38263,3320,3850,38256,171,5005,107,38260,176,2273,35581,38264,31622,4843,139,214,204,4803,31935,38246,38262,1090,1232,31777,1906,38249,1091,6634,1781,22788,11987,38258,38259,36426,38257,31874,36494,38254,38252,38255],"class_list":["post-5487","post","type-post","status-publish","format-standard","has-post-thumbnail","category-cable-for-shore-connection-systems","category-din-vde-0250-mining-cable","category-medium-voltage-cable","category-uncategorized","category-reeling-cable","tag-0-6-1kv-trailing-cable","tag-3x50mm2-mining-cable","tag-anhui-feichun-cable","tag-as-nzs-1802-trailing-cable","tag-atlas-copco-boltec-cable","tag-boltec-235-cable-specifications","tag-boltec-feed-cable-replacement","tag-boltec-mc-power-cable","tag-boltec-trailing-cable-specifications","tag-cable-reel-system","tag-continuous-miner-cable","tag-cpe-sheath-vs-rubber-sheath-mining-cable","tag-epr-insulated-mining-cable","tag-epr-vs-xlpe-mining-cable","tag-epr","tag-explosion-proof-mining-cable","tag-ground-check-conductor","tag-heavy-duty-e-loader-mining-cable","tag-how-to-replace-atlas-copco-boltec-feed-cable","tag-icea-s-75-381-2","tag-iec-60502-power-cable","tag-mining-cable-bend-radius-requirements","tag-mining-cable-current-capacity-calculation","tag-mining-cable-selection","tag-mining-cable-voltage-drop-calculation","tag-mining-cables","tag-mining-power-cable","tag-mining-trailing-cable","tag-msha-approved-trailing-cable","tag-mt-818-coal-mine-cable","tag-rock-bolting-rig-cable","tag-rock-bolting-rig-electrical-requirements","tag-roof-bolter-cable","tag-shuttle-car-cable","tag-trailing-cable-ground-check-conductor","tag-type-g-gc-mining-cable","tag-underground-hard-rock-mining","tag-underground-mining-cable","tag-underground-mining-cable-selection-guide","tag-voltage-drop-calculation","tag-22788","tag-11987","tag-mt818","tag-38259","tag-36426","tag-38257","tag-31874","tag-36494","tag-38254","tag-boltec","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/5487","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=5487"}],"version-history":[{"count":2,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/5487\/revisions"}],"predecessor-version":[{"id":5490,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/5487\/revisions\/5490"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/5488"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=5487"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=5487"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=5487"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}