{"id":5303,"date":"2026-01-28T13:45:50","date_gmt":"2026-01-28T05:45:50","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=5303"},"modified":"2026-01-28T13:45:55","modified_gmt":"2026-01-28T05:45:55","slug":"msha-approval-does-your-type-w-cable-carry-the-p-136-msha-marking","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/msha-approval-does-your-type-w-cable-carry-the-p-136-msha-marking\/","title":{"rendered":"MSHA Approval: Does Your Type W Cable Carry the P-136-MSHA Marking?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">MSHA\u8ba4\u8bc1:\u60a8\u7684W\u578b\u7535\u7f06\u662f\u5426\u5e26\u6709P-136-MSHA\u6807\u8bc6?<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-dominant-color=\"515a6c\" data-has-transparency=\"false\" style=\"--dominant-color: #515a6c;\" loading=\"lazy\" decoding=\"async\" width=\"1051\" height=\"628\" sizes=\"auto, (max-width: 1051px) 100vw, 1051px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-652-1051x628.avif\" alt=\"\" class=\"wp-image-5304 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-652-1051x628.avif 1051w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-652-300x179.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-652-768x459.avif 768w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-652-400x239.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-652-800x478.avif 800w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-652-832x497.avif 832w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-652.avif 1094w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n    <meta charset=\"UTF-8\">\n    <meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n    <meta name=\"description\" content=\"MSHA Approval Requirements for Type W Cables - Understanding P-136-MSHA marking requirements for underground mining applications. Anhui Feichun Special Cable Co., Ltd.\">\n    <meta name=\"keywords\" content=\"Type W cable, MSHA approval, P-136-MSHA, underground mining cable, 30 CFR Part 7, flame resistant cable, portable power cable, mining safety\">\n    <title>MSHA Approval: Type W Cable P-136-MSHA Marking Requirements | Anhui Feichun Special Cable<\/title>\n    \n    <style>\n        \/* Root Variables for Light\/Dark Mode *\/\n        :root {\n            --bg-primary: #ffffff;\n            --bg-secondary: #f8f9fa;\n            --text-primary: #1a1a1a;\n            --text-secondary: #4a4a4a;\n            --accent-primary: #2c5282;\n            --accent-secondary: #3182ce;\n            --border-color: #e2e8f0;\n            --table-header: #2d3748;\n            --table-row-alt: #f7fafc;\n            --link-color: #2563eb;\n            --shadow: rgba(0, 0, 0, 0.1);\n            --warning-bg: #fef3c7;\n            --warning-border: #f59e0b;\n        }\n\n        @media (prefers-color-scheme: dark) {\n            :root {\n                --bg-primary: #1a202c;\n                --bg-secondary: #2d3748;\n                --text-primary: #f7fafc;\n                --text-secondary: #cbd5e0;\n                --accent-primary: #4299e1;\n                --accent-secondary: #63b3ed;\n                --border-color: #4a5568;\n                --table-header: #1a202c;\n                --table-row-alt: #2d3748;\n                --link-color: #60a5fa;\n                --shadow: rgba(0, 0, 0, 0.3);\n                --warning-bg: #78350f;\n                --warning-border: #f59e0b;\n            }\n        }\n\n        * {\n            margin: 0;\n            padding: 0;\n            box-sizing: border-box;\n        }\n\n        body {\n            font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', 'Roboto', 'Helvetica Neue', Arial, sans-serif;\n            line-height: 1.7;\n            color: var(--text-primary);\n            background-color: var(--bg-primary);\n            transition: background-color 0.2s ease, color 0.2s ease;\n        }\n\n        .container {\n            max-width: 1200px;\n            margin: 0 auto;\n            padding: 20px;\n        }\n\n        header {\n            background-color: var(--bg-secondary);\n            border-bottom: 3px solid var(--accent-primary);\n            padding: 30px 20px;\n            margin-bottom: 40px;\n        }\n\n        h1 {\n            font-size: 2em;\n            color: var(--accent-primary);\n            margin-bottom: 10px;\n            font-weight: 700;\n        }\n\n        h1 .chinese {\n            display: block;\n            font-size: 0.65em;\n            color: var(--text-secondary);\n            margin-top: 8px;\n            font-weight: 400;\n        }\n\n        .company-name {\n            font-size: 1.1em;\n            color: var(--text-secondary);\n            margin-top: 15px;\n        }\n\n        .company-name .chinese {\n            font-size: 0.95em;\n            margin-left: 10px;\n        }\n\n        h2 {\n            font-size: 1.6em;\n            color: var(--accent-primary);\n            margin: 40px 0 20px 0;\n            padding-bottom: 10px;\n            border-bottom: 2px solid var(--border-color);\n        }\n\n        h2 .chinese {\n            font-size: 0.7em;\n            color: var(--text-secondary);\n            margin-left: 15px;\n            font-weight: 400;\n        }\n\n        h3 {\n            font-size: 1.3em;\n            color: var(--accent-secondary);\n            margin: 30px 0 15px 0;\n        }\n\n        h3 .chinese {\n            font-size: 0.75em;\n            color: var(--text-secondary);\n            margin-left: 10px;\n            font-weight: 400;\n        }\n\n        p {\n            margin-bottom: 18px;\n            text-align: justify;\n        }\n\n        .intro {\n            background-color: var(--bg-secondary);\n            padding: 25px;\n            border-left: 4px solid var(--accent-primary);\n            margin-bottom: 30px;\n        }\n\n        .warning-box {\n            background-color: var(--warning-bg);\n            border-left: 4px solid var(--warning-border);\n            padding: 20px;\n            margin: 25px 0;\n        }\n\n        .warning-box h3 {\n            color: var(--warning-border);\n            margin-top: 0;\n        }\n\n        table {\n            width: 100%;\n            border-collapse: collapse;\n            margin: 25px 0;\n            background-color: var(--bg-primary);\n            box-shadow: 0 2px 8px var(--shadow);\n        }\n\n        th {\n            background-color: var(--table-header);\n            color: #ffffff;\n            padding: 16px;\n            text-align: left;\n            font-weight: 600;\n            font-size: 0.95em;\n            letter-spacing: 0.5px;\n        }\n\n        th .chinese {\n            display: block;\n            font-size: 0.85em;\n            font-weight: 400;\n            margin-top: 4px;\n            opacity: 0.9;\n        }\n\n        td {\n            padding: 14px 16px;\n            border-bottom: 1px solid var(--border-color);\n        }\n\n        tr:nth-child(even) {\n            background-color: var(--table-row-alt);\n        }\n\n        tr:hover {\n            background-color: var(--border-color);\n            transition: background-color 0.15s ease;\n        }\n\n        .spec-label {\n            font-weight: 600;\n            color: var(--text-primary);\n        }\n\n        .chinese-note {\n            color: var(--text-secondary);\n            font-size: 0.9em;\n            margin-left: 8px;\n        }\n\n        .highlight-box {\n            background-color: var(--bg-secondary);\n            border-left: 4px solid var(--accent-secondary);\n            padding: 20px;\n            margin: 25px 0;\n        }\n\n        .citation {\n            font-size: 0.85em;\n            color: var(--text-secondary);\n            margin-top: 30px;\n            padding: 15px;\n            background-color: var(--bg-secondary);\n            border-radius: 4px;\n        }\n\n        .citation a {\n            color: var(--link-color);\n            text-decoration: none;\n        }\n\n        .citation a:hover {\n            text-decoration: underline;\n        }\n\n        .contact-section {\n            background-color: var(--bg-secondary);\n            padding: 30px;\n            margin: 40px 0;\n            border-radius: 6px;\n        }\n\n        .contact-grid {\n            display: grid;\n            grid-template-columns: repeat(auto-fit, minmax(250px, 1fr));\n            gap: 20px;\n            margin-top: 20px;\n        }\n\n        .contact-item {\n            padding: 15px;\n            background-color: var(--bg-primary);\n            border-radius: 4px;\n        }\n\n        .contact-label {\n            font-weight: 600;\n            color: var(--accent-primary);\n            margin-bottom: 8px;\n        }\n\n        .contact-value {\n            color: var(--text-primary);\n        }\n\n        .contact-value a {\n            color: var(--link-color);\n            text-decoration: none;\n        }\n\n        .contact-value a:hover {\n            text-decoration: underline;\n        }\n\n        footer {\n            margin-top: 60px;\n            padding: 30px 20px;\n            background-color: var(--bg-secondary);\n            text-align: center;\n            color: var(--text-secondary);\n            border-top: 3px solid var(--accent-primary);\n        }\n\n        .data-point {\n            font-weight: 600;\n            color: var(--accent-primary);\n        }\n\n        .code-example {\n            background-color: var(--bg-secondary);\n            padding: 15px;\n            border-radius: 4px;\n            font-family: 'Courier New', monospace;\n            margin: 15px 0;\n            overflow-x: auto;\n        }\n\n        @media (max-width: 768px) {\n            h1 {\n                font-size: 1.6em;\n            }\n            \n            table {\n                font-size: 0.9em;\n            }\n            \n            th, td {\n                padding: 10px;\n            }\n        }\n    <\/style>\n<\/head>\n<body>\n    <header>\n        <div class=\"container\">\n            <h1>\n                MSHA Approval: Does Your Type W Cable Carry the P-136-MSHA Marking?\n                <span class=\"chinese\">MSHA\u8ba4\u8bc1:\u60a8\u7684W\u578b\u7535\u7f06\u662f\u5426\u5e26\u6709P-136-MSHA\u6807\u8bc6?<\/span>\n            <\/h1>\n            <div class=\"company-name\">\n                Anhui Feichun Special Cable Co., Ltd.\n                <span class=\"chinese\">\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/span>\n            <\/div>\n        <\/div>\n    <\/header>\n\n    <main class=\"container\">\n        <div class=\"intro\">\n            <p>Understanding Mine Safety and Health Administration approval markings on Type W portable power cables is essential for compliance with United States underground mining regulations. The P-136-MSHA designation represents a specific manufacturer approval code combined with MSHA certification, indicating that a cable has successfully passed rigorous flame resistance testing and meets federal safety standards for underground mining applications. This comprehensive guide examines MSHA approval requirements, explains the significance of manufacturer-specific approval numbers, and clarifies when Type W cables require MSHA certification for legal underground deployment.<\/p>\n            <p class=\"chinese-note\">\u4e86\u89e3W\u578b\u4fbf\u643a\u5f0f\u7535\u529b\u7535\u7f06\u4e0a\u7684\u77ff\u5c71\u5b89\u5168\u4e0e\u5065\u5eb7\u7ba1\u7406\u5c40(MSHA)\u8ba4\u8bc1\u6807\u8bc6\u5bf9\u4e8e\u7b26\u5408\u7f8e\u56fd\u5730\u4e0b\u91c7\u77ff\u6cd5\u89c4\u81f3\u5173\u91cd\u8981\u3002P-136-MSHA\u6807\u8bc6\u4ee3\u8868\u7279\u5b9a\u5236\u9020\u5546\u6279\u51c6\u4ee3\u7801\u4e0eMSHA\u8ba4\u8bc1\u7684\u7ec4\u5408,\u8868\u660e\u7535\u7f06\u5df2\u6210\u529f\u901a\u8fc7\u4e25\u683c\u7684\u963b\u71c3\u6d4b\u8bd5\u5e76\u7b26\u5408\u5730\u4e0b\u91c7\u77ff\u5e94\u7528\u7684\u8054\u90a6\u5b89\u5168\u6807\u51c6\u3002\u672c\u6307\u5357\u8be6\u7ec6\u4ecb\u7ecd\u4e86MSHA\u6279\u51c6\u8981\u6c42,\u89e3\u91ca\u4e86\u5236\u9020\u5546\u7279\u5b9a\u6279\u51c6\u7f16\u53f7\u7684\u610f\u4e49,\u5e76\u9610\u660e\u4e86W\u578b\u7535\u7f06\u4f55\u65f6\u9700\u8981MSHA\u8ba4\u8bc1\u624d\u80fd\u5408\u6cd5\u5730\u4e0b\u90e8\u7f72\u3002<\/p>\n        <\/div>\n\n        <h2>Understanding Type W Cable Applications <span class=\"chinese\">\u4e86\u89e3W\u578b\u7535\u7f06\u5e94\u7528<\/span><\/h2>\n        \n        <p>Type W cables represent heavy-duty portable power cables specifically engineered for demanding industrial environments where flexibility, durability, and resistance to harsh conditions are paramount. These cables feature rope-lay stranded copper conductors insulated with Ethylene Propylene Rubber and protected by robust Chlorinated Polyethylene or EPDM outer jackets, providing exceptional resistance to oil, sunlight, water, abrasion, and temperature extremes ranging from negative forty degrees Celsius to positive ninety degrees Celsius. The voltage rating typically reaches two thousand volts, making Type W cables suitable for both temporary and permanent power distribution applications across diverse industrial sectors.<\/p>\n\n        <p>Common applications for Type W cables encompass portable power generation equipment, motor and battery leads, construction site temporary power distribution, oil drilling platforms, shipyards, marina shore power connections, entertainment industry lighting systems, and mining operations. In mining contexts specifically, Type W cables serve critical functions powering mobile equipment, portable pumps, temporary lighting installations, and auxiliary power systems where conventional fixed wiring proves impractical due to operational flexibility requirements.<\/p>\n\n        <div class=\"highlight-box\">\n            <h3>Type W Cable Technical Specifications <span class=\"chinese\">W\u578b\u7535\u7f06\u6280\u672f\u89c4\u683c<\/span><\/h3>\n            <table>\n                <thead>\n                    <tr>\n                        <th>Parameter <span class=\"chinese\">\u53c2\u6570<\/span><\/th>\n                        <th>Specification <span class=\"chinese\">\u89c4\u683c<\/span><\/th>\n                    <\/tr>\n                <\/thead>\n                <tbody>\n                    <tr>\n                        <td class=\"spec-label\">Voltage Rating <span class=\"chinese-note\">\u989d\u5b9a\u7535\u538b<\/span><\/td>\n                        <td>600V to 2000V <span class=\"chinese-note\">600\u4f0f\u81f32000\u4f0f<\/span><\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">Conductor Material <span class=\"chinese-note\">\u5bfc\u4f53\u6750\u6599<\/span><\/td>\n                        <td>Rope-lay stranded bare or tinned copper <span class=\"chinese-note\">\u7ef3\u7ede\u88f8\u94dc\u6216\u9540\u9521\u94dc<\/span><\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">Conductor Class <span class=\"chinese-note\">\u5bfc\u4f53\u7b49\u7ea7<\/span><\/td>\n                        <td>ASTM B172 Class K (flexible stranding) <span class=\"chinese-note\">ASTM B172 K\u7ea7(\u67d4\u6027\u7ede\u5408)<\/span><\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">Insulation Type <span class=\"chinese-note\">\u7edd\u7f18\u7c7b\u578b<\/span><\/td>\n                        <td>EPR (Ethylene Propylene Rubber) <span class=\"chinese-note\">\u4e59\u4e19\u6a61\u80f6<\/span><\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">Jacket Material <span class=\"chinese-note\">\u62a4\u5957\u6750\u6599<\/span><\/td>\n                        <td>CPE or EPDM (Chlorinated Polyethylene \/ Ethylene Propylene Diene Monomer) <span class=\"chinese-note\">\u6c2f\u5316\u805a\u4e59\u70ef\/\u4e09\u5143\u4e59\u4e19\u6a61\u80f6<\/span><\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">Temperature Rating <span class=\"chinese-note\">\u6e29\u5ea6\u7b49\u7ea7<\/span><\/td>\n                        <td>-40\u00b0C to +90\u00b0C wet\/dry operation <span class=\"chinese-note\">-40\u00b0C\u81f3+90\u00b0C\u5e72\u6e7f\u8fd0\u884c<\/span><\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">Standards Compliance <span class=\"chinese-note\">\u7b26\u5408\u6807\u51c6<\/span><\/td>\n                        <td>UL 1650, CSA C22.2 No. 96, ICEA S-75-381, NEMA WC 58 <span class=\"chinese-note\">UL 1650, CSA C22.2\u7b2c96\u53f7, ICEA S-75-381, NEMA WC 58<\/span><\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">Configuration Options <span class=\"chinese-note\">\u914d\u7f6e\u9009\u9879<\/span><\/td>\n                        <td>Single conductor, 2-conductor, 3-conductor, 4-conductor <span class=\"chinese-note\">\u5355\u82af,\u53cc\u82af,\u4e09\u82af,\u56db\u82af<\/span><\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">Special Properties <span class=\"chinese-note\">\u7279\u6b8a\u6027\u80fd<\/span><\/td>\n                        <td>Oil resistant, sunlight resistant, flame resistant, water submersible <span class=\"chinese-note\">\u8010\u6cb9\u3001\u8010\u9633\u5149\u3001\u963b\u71c3\u3001\u53ef\u6c34\u4e0b\u4f7f\u7528<\/span><\/td>\n                    <\/tr>\n                <\/tbody>\n            <\/table>\n        <\/div>\n\n        <h2>MSHA Approval Requirements for Underground Mining <span class=\"chinese\">\u5730\u4e0b\u91c7\u77ff\u7684MSHA\u6279\u51c6\u8981\u6c42<\/span><\/h2>\n\n        <p>The Mine Safety and Health Administration, an agency within the United States Department of Labor, establishes comprehensive safety standards for mining operations through Title 30 of the Code of Federal Regulations. For underground mining applications specifically, MSHA mandates that all trailing cables and portable power cables used in underground environments must receive formal MSHA acceptance or approval as flame-resistant materials. This requirement stems from the inherent fire hazards present in underground mining operations, where confined spaces, potential methane accumulation in coal mines, combustible dust, and limited escape routes create catastrophic fire risk scenarios that demand stringent cable safety standards.<\/p>\n\n        <p>The regulatory framework governing underground mining cables appears primarily in 30 CFR Part 7, Subpart K (Testing, Evaluation, and Approval of Mining Products) and 30 CFR Part 18, Section 18.64 (Flame Resistance of Electric Cables). These regulations specify detailed testing protocols that cables must successfully complete before receiving MSHA acceptance. Underground coal mines fall under additional requirements specified in 30 CFR Part 75, while underground metal and nonmetal mines must comply with 30 CFR Part 57, both of which explicitly require MSHA-approved or accepted flame-resistant cables for underground trailing cable applications.<\/p>\n\n        <div class=\"warning-box\">\n            <h3>Critical Compliance Requirement <span class=\"chinese\">\u5173\u952e\u5408\u89c4\u8981\u6c42<\/span><\/h3>\n            <p><strong>Underground mining operations in the United States are legally prohibited from deploying Type W cables or any portable power cables that lack proper MSHA approval markings for underground use.<\/strong> Operators found using non-approved cables in underground environments face significant penalties including citations, fines, operational shutdowns, and potential civil or criminal liability in the event of fire-related incidents. Surface mining operations typically do not require MSHA flame resistance approval for cables, though other electrical safety standards still apply.<\/p>\n            <p class=\"chinese-note\"><strong>\u7f8e\u56fd\u7684\u5730\u4e0b\u91c7\u77ff\u4f5c\u4e1a\u5728\u6cd5\u5f8b\u4e0a\u7981\u6b62\u90e8\u7f72\u7f3a\u4e4f\u9002\u5f53MSHA\u5730\u4e0b\u4f7f\u7528\u6279\u51c6\u6807\u8bc6\u7684W\u578b\u7535\u7f06\u6216\u4efb\u4f55\u4fbf\u643a\u5f0f\u7535\u529b\u7535\u7f06\u3002<\/strong>\u5728\u5730\u4e0b\u73af\u5883\u4e2d\u4f7f\u7528\u672a\u7ecf\u6279\u51c6\u7535\u7f06\u7684\u8fd0\u8425\u5546\u5c06\u9762\u4e34\u91cd\u5927\u5904\u7f5a,\u5305\u62ec\u8fdd\u89c4\u901a\u77e5\u3001\u7f5a\u6b3e\u3001\u8fd0\u8425\u505c\u5de5,\u4ee5\u53ca\u5728\u53d1\u751f\u706b\u707e\u76f8\u5173\u4e8b\u6545\u65f6\u7684\u6f5c\u5728\u6c11\u4e8b\u6216\u5211\u4e8b\u8d23\u4efb\u3002\u5730\u8868\u91c7\u77ff\u4f5c\u4e1a\u901a\u5e38\u4e0d\u8981\u6c42\u7535\u7f06\u5177\u6709MSHA\u963b\u71c3\u6279\u51c6,\u5c3d\u7ba1\u5176\u4ed6\u7535\u6c14\u5b89\u5168\u6807\u51c6\u4ecd\u7136\u9002\u7528\u3002<\/p>\n        <\/div>\n\n        <h2>Decoding the P-136-MSHA Marking <span class=\"chinese\">\u89e3\u8bfbP-136-MSHA\u6807\u8bc6<\/span><\/h2>\n\n        <p>The marking system used on MSHA-approved cables follows a standardized format that conveys essential information about the cable&#8217;s certification status and manufacturing origin. A typical MSHA approval marking appears on the cable jacket as a printed legend containing multiple elements, with the MSHA approval number being the most critical component for verification purposes.<\/p>\n\n        <h3>Understanding the Marking Components <span class=\"chinese\">\u4e86\u89e3\u6807\u8bc6\u7ec4\u6210\u90e8\u5206<\/span><\/h3>\n\n        <p>The P-136-MSHA designation breaks down into specific meaningful components. The letter P serves as a prefix assigned by MSHA to certain cable manufacturers, while the numerical portion (136 in this example) represents the specific manufacturer code assigned by MSHA to that particular company. Different manufacturers hold different MSHA approval codes, creating a traceable system linking each approved cable back to its certified manufacturer. The MSHA suffix explicitly confirms that the product has received Mine Safety and Health Administration acceptance or approval under the applicable Code of Federal Regulations testing standards.<\/p>\n\n        <div class=\"code-example\">\n            <strong>Example Cable Jacket Marking:<\/strong><br>\n            MANUFACTURER NAME 4 AWG 3\/C TYPE W PORTABLE POWER CABLE<br>\n            2000V 90\u00b0C WET OR DRY OIL AND SUN RES (UL) <strong>P-136-35-MSHA<\/strong><br>\n            CSA TYPE W FT1\/FT5 (-40\u00b0C) RoHS\n        <\/div>\n\n        <p>In the example marking shown above, the complete MSHA approval number appears as P-136-35-MSHA, where the additional numerical suffix (35) may indicate a specific cable construction variant or approval submission within that manufacturer&#8217;s approved product line. Different cable configurations from the same manufacturer might carry sequential approval numbers such as P-136-01-MSHA, P-136-02-MSHA, and so forth, with each number corresponding to a specific tested and approved cable design.<\/p>\n\n        <h3>Manufacturer Code Examples <span class=\"chinese\">\u5236\u9020\u5546\u4ee3\u7801\u793a\u4f8b<\/span><\/h3>\n\n        <table>\n            <thead>\n                <tr>\n                    <th>MSHA Code Example <span class=\"chinese\">MSHA\u4ee3\u7801\u793a\u4f8b<\/span><\/th>\n                    <th>Typical Format <span class=\"chinese\">\u5178\u578b\u683c\u5f0f<\/span><\/th>\n                    <th>Application <span class=\"chinese\">\u5e94\u7528<\/span><\/th>\n                <\/tr>\n            <\/thead>\n            <tbody>\n                <tr>\n                    <td class=\"spec-label\">P-07-KA100010-MSHA<\/td>\n                    <td>Prefix-Manufacturer-Product-MSHA<\/td>\n                    <td>Type W portable power cable, underground approved <span class=\"chinese-note\">W\u578b\u4fbf\u643a\u5f0f\u7535\u529b\u7535\u7f06,\u5730\u4e0b\u6279\u51c6<\/span><\/td>\n                <\/tr>\n                <tr>\n                    <td class=\"spec-label\">P-136-35-MSHA<\/td>\n                    <td>Prefix-Manufacturer-Variant-MSHA<\/td>\n                    <td>Type W cable specific construction <span class=\"chinese-note\">W\u578b\u7535\u7f06\u7279\u5b9a\u7ed3\u6784<\/span><\/td>\n                <\/tr>\n                <tr>\n                    <td class=\"spec-label\">7K-136047-MSHA<\/td>\n                    <td>Category-Manufacturer-Product-MSHA<\/td>\n                    <td>Alternative approval format <span class=\"chinese-note\">\u66ff\u4ee3\u6279\u51c6\u683c\u5f0f<\/span><\/td>\n                <\/tr>\n            <\/tbody>\n        <\/table>\n\n        <p>It bears emphasis that the absence of an MSHA approval marking on a Type W cable jacket definitively indicates that the cable has not received MSHA acceptance for underground mining applications. While such unmarked Type W cables remain entirely suitable and compliant for surface mining operations, industrial facilities, construction sites, entertainment applications, and other non-underground environments, deploying them in underground mines constitutes a clear regulatory violation regardless of the cable&#8217;s otherwise excellent electrical and mechanical properties.<\/p>\n\n        <h2>MSHA Testing and Approval Process <span class=\"chinese\">MSHA\u6d4b\u8bd5\u548c\u6279\u51c6\u6d41\u7a0b<\/span><\/h2>\n\n        <p>Manufacturers seeking MSHA approval for their cable products must submit formal applications to the MSHA Approval and Certification Center located in Triadelphia, West Virginia. The application process requires comprehensive technical documentation including detailed engineering drawings showing all cable construction elements, complete materials specifications for conductors, insulation compounds, fillers, and jacket materials, and voltage ratings with corresponding ampacity calculations. The manufacturer must also provide representative cable samples for physical testing and specify the design standards used in the cable construction.<\/p>\n\n        <h3>Flame Resistance Testing Requirements <span class=\"chinese\">\u963b\u71c3\u6d4b\u8bd5\u8981\u6c42<\/span><\/h3>\n\n        <p>The cornerstone of MSHA cable approval centers on demonstrating adequate flame resistance characteristics through standardized testing protocols. MSHA conducts vertical flame tests where cable samples are suspended vertically and subjected to a controlled flame applied to the lower end of the sample. The test flame specifications include precise parameters for flame height (typically five inches for the outer cone with a three-inch inner cone), application duration, and heating current calculations. The cable must demonstrate self-extinguishing properties, meaning that combustion must cease within specified time limits after flame source removal, and the cable must not propagate flame beyond defined vertical propagation limits.<\/p>\n\n        <p>Additional testing may evaluate cable performance under various conditions including conductor temperature measurements during flame application, insulation integrity after thermal exposure, and jacket material combustion characteristics. Cables that successfully complete all testing requirements receive an MSHA acceptance number, which the manufacturer then incorporates into the permanent cable jacket markings for all production units manufactured under that approval.<\/p>\n\n        <div class=\"highlight-box\">\n            <h3>Approved Cable Documentation <span class=\"chinese\">\u8ba4\u53ef\u7535\u7f06\u6587\u4ef6<\/span><\/h3>\n            <p>MSHA maintains comprehensive public listings of all accepted flame-resistant cables, published regularly and available through the MSHA website and the Approval and Certification Center. These listings identify each approved cable by manufacturer name, MSHA acceptance number, cable type designation, and approved configurations. Mining operators can reference these official MSHA lists to verify that cables bearing MSHA markings legitimately hold current approval status. The most recent version of these listings should always be consulted, as MSHA may revoke approvals, manufacturers may transfer production facilities, or companies may undergo ownership changes affecting approval status.<\/p>\n        <\/div>\n\n        <h2>When MSHA Approval is Mandatory <span class=\"chinese\">\u4f55\u65f6\u9700\u8981MSHA\u6279\u51c6<\/span><\/h2>\n\n        <p>The distinction between applications requiring MSHA approval versus those where approval is unnecessary depends primarily on the operational environment and specific mining regulations applicable to each operation type. Understanding these distinctions helps procurement professionals, electrical engineers, and mining operators make appropriate cable selection decisions while maintaining full regulatory compliance.<\/p>\n\n        <h3>Applications Requiring MSHA Approval <span class=\"chinese\">\u9700\u8981MSHA\u6279\u51c6\u7684\u5e94\u7528<\/span><\/h3>\n\n        <table>\n            <thead>\n                <tr>\n                    <th>Mining Environment <span class=\"chinese\">\u91c7\u77ff\u73af\u5883<\/span><\/th>\n                    <th>Regulatory Requirement <span class=\"chinese\">\u76d1\u7ba1\u8981\u6c42<\/span><\/th>\n                    <th>CFR Reference <span class=\"chinese\">CFR\u53c2\u8003<\/span><\/th>\n                <\/tr>\n            <\/thead>\n            <tbody>\n                <tr>\n                    <td class=\"spec-label\">Underground Coal Mines <span class=\"chinese-note\">\u5730\u4e0b\u7164\u77ff<\/span><\/td>\n                    <td>MSHA-approved or accepted flame-resistant cables mandatory for all trailing cables and portable power cables <span class=\"chinese-note\">\u6240\u6709\u62d6\u7f06\u548c\u4fbf\u643a\u5f0f\u7535\u529b\u7535\u7f06\u90fd\u5fc5\u987b\u4f7f\u7528MSHA\u6279\u51c6\u6216\u8ba4\u53ef\u7684\u963b\u71c3\u7535\u7f06<\/span><\/td>\n                    <td>30 CFR Part 75<\/td>\n                <\/tr>\n                <tr>\n                    <td class=\"spec-label\">Underground Metal\/Nonmetal Mines <span class=\"chinese-note\">\u5730\u4e0b\u91d1\u5c5e\/\u975e\u91d1\u5c5e\u77ff\u5c71<\/span><\/td>\n                    <td>Underground trailing cables must be MSHA-accepted or approved as flame resistant <span class=\"chinese-note\">\u5730\u4e0b\u62d6\u7f06\u5fc5\u987b\u7ecfMSHA\u8ba4\u53ef\u6216\u6279\u51c6\u4e3a\u963b\u71c3<\/span><\/td>\n                    <td>30 CFR Part 57<\/td>\n                <\/tr>\n                <tr>\n                    <td class=\"spec-label\">Gassy Underground Mines <span class=\"chinese-note\">\u74e6\u65af\u5730\u4e0b\u77ff\u4e95<\/span><\/td>\n                    <td>All electrical equipment and cables must meet Part 18 or Part 7 approval requirements <span class=\"chinese-note\">\u6240\u6709\u7535\u6c14\u8bbe\u5907\u548c\u7535\u7f06\u5fc5\u987b\u7b26\u5408\u7b2c18\u90e8\u5206\u6216\u7b2c7\u90e8\u5206\u6279\u51c6\u8981\u6c42<\/span><\/td>\n                    <td>30 CFR Part 18<\/td>\n                <\/tr>\n            <\/tbody>\n            <\/table>\n\n        <h3>Applications NOT Requiring MSHA Approval <span class=\"chinese\">\u4e0d\u9700\u8981MSHA\u6279\u51c6\u7684\u5e94\u7528<\/span><\/h3>\n\n        <table>\n            <thead>\n                <tr>\n                    <th>Application Environment <span class=\"chinese\">\u5e94\u7528\u73af\u5883<\/span><\/th>\n                    <th>Cable Requirements <span class=\"chinese\">\u7535\u7f06\u8981\u6c42<\/span><\/th>\n                <\/tr>\n            <\/thead>\n            <tbody>\n                <tr>\n                    <td class=\"spec-label\">Surface Mining Operations <span class=\"chinese-note\">\u5730\u8868\u91c7\u77ff\u4f5c\u4e1a<\/span><\/td>\n                    <td>Standard Type W cables meeting UL, CSA, and NEC requirements are acceptable without MSHA flame resistance approval <span class=\"chinese-note\">\u7b26\u5408UL\u3001CSA\u548cNEC\u8981\u6c42\u7684\u6807\u51c6W\u578b\u7535\u7f06\u53ef\u4ee5\u4f7f\u7528,\u65e0\u9700MSHA\u963b\u71c3\u6279\u51c6<\/span><\/td>\n                <\/tr>\n                <tr>\n                    <td class=\"spec-label\">General Industrial Facilities <span class=\"chinese-note\">\u4e00\u822c\u5de5\u4e1a\u8bbe\u65bd<\/span><\/td>\n                    <td>Type W cables certified to UL 1650 and applicable electrical codes suffice <span class=\"chinese-note\">\u7b26\u5408UL 1650\u548c\u9002\u7528\u7535\u6c14\u89c4\u8303\u8ba4\u8bc1\u7684W\u578b\u7535\u7f06\u5373\u53ef<\/span><\/td>\n                <\/tr>\n                <tr>\n                    <td class=\"spec-label\">Construction Sites <span class=\"chinese-note\">\u5efa\u7b51\u5de5\u5730<\/span><\/td>\n                    <td>NEC Article 400 compliance required; MSHA approval not necessary <span class=\"chinese-note\">\u9700\u8981\u7b26\u5408NEC\u7b2c400\u6761;\u65e0\u9700MSHA\u6279\u51c6<\/span><\/td>\n                <\/tr>\n                <tr>\n                    <td class=\"spec-label\">Entertainment\/Theatrical <span class=\"chinese-note\">\u5a31\u4e50\/\u5267\u573a<\/span><\/td>\n                    <td>Type W cables meeting electrical code and local fire marshal requirements <span class=\"chinese-note\">\u7b26\u5408\u7535\u6c14\u89c4\u8303\u548c\u5f53\u5730\u6d88\u9632\u8981\u6c42\u7684W\u578b\u7535\u7f06<\/span><\/td>\n                <\/tr>\n                <tr>\n                    <td class=\"spec-label\">Marine\/Maritime <span class=\"chinese-note\">\u6d77\u4e8b\/\u6d77\u6d0b<\/span><\/td>\n                    <td>Coast Guard and maritime electrical standards apply; MSHA approval not required <span class=\"chinese-note\">\u9002\u7528\u6d77\u5cb8\u8b66\u536b\u961f\u548c\u6d77\u4e8b\u7535\u6c14\u6807\u51c6;\u4e0d\u9700\u8981MSHA\u6279\u51c6<\/span><\/td>\n                <\/tr>\n                <tr>\n                    <td class=\"spec-label\">Oil &#038; Gas (Surface) <span class=\"chinese-note\">\u77f3\u6cb9\u548c\u5929\u7136\u6c14(\u5730\u8868)<\/span><\/td>\n                    <td>Hazardous location certifications (Class I Division ratings) required rather than MSHA approval <span class=\"chinese-note\">\u9700\u8981\u5371\u9669\u573a\u6240\u8ba4\u8bc1(I\u7c7b\u533a\u57df\u7b49\u7ea7)\u800c\u975eMSHA\u6279\u51c6<\/span><\/td>\n                <\/tr>\n            <\/tbody>\n        <\/table>\n\n        <h2>Verification and Compliance Best Practices <span class=\"chinese\">\u9a8c\u8bc1\u548c\u5408\u89c4\u6700\u4f73\u5b9e\u8df5<\/span><\/h2>\n\n        <p>Mining operators and equipment managers implementing robust cable procurement and verification procedures significantly reduce regulatory compliance risks while enhancing overall electrical safety performance. The verification process should commence during the procurement specification phase, where purchase orders for underground mining applications must explicitly specify MSHA approval requirements and request confirmation of current approval status with the specific MSHA acceptance number that will appear on the delivered cable.<\/p>\n\n        <p>Upon cable delivery and before deployment into underground service, receiving personnel should conduct thorough physical inspections of cable jacket markings to confirm the presence and legibility of MSHA approval numbers. The marked approval number should then be cross-referenced against current MSHA acceptance listings published by the Approval and Certification Center. This verification step confirms that the manufacturer holds valid approval status and that no subsequent approval revocations or transfers have occurred since the cable&#8217;s manufacture.<\/p>\n\n        <p>Documentation maintenance represents another critical compliance element. Mining operations should retain complete records including cable procurement specifications, supplier certifications attesting to MSHA approval status, copies of MSHA acceptance letters where available, and photographic documentation of cable jacket markings showing approval numbers. During MSHA inspections, inspectors routinely examine cable markings and may request supporting documentation proving that cables deployed underground carry proper approvals.<\/p>\n\n        <div class=\"highlight-box\">\n            <h3>Procurement Checklist for Underground Mining Cables <span class=\"chinese\">\u5730\u4e0b\u91c7\u77ff\u7535\u7f06\u91c7\u8d2d\u6e05\u5355<\/span><\/h3>\n            <table>\n                <thead>\n                    <tr>\n                        <th>Verification Step <span class=\"chinese\">\u9a8c\u8bc1\u6b65\u9aa4<\/span><\/th>\n                        <th>Action Required <span class=\"chinese\">\u6240\u9700\u884c\u52a8<\/span><\/th>\n                    <\/tr>\n                <\/thead>\n                <tbody>\n                    <tr>\n                        <td class=\"spec-label\">Specification Review <span class=\"chinese-note\">\u89c4\u683c\u5ba1\u67e5<\/span><\/td>\n                        <td>Purchase order must explicitly require MSHA approval for underground use <span class=\"chinese-note\">\u91c7\u8d2d\u8ba2\u5355\u5fc5\u987b\u660e\u786e\u8981\u6c42\u5730\u4e0b\u4f7f\u7528\u7684MSHA\u6279\u51c6<\/span><\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">Supplier Certification <span class=\"chinese-note\">\u4f9b\u5e94\u5546\u8ba4\u8bc1<\/span><\/td>\n                        <td>Request manufacturer certification letter confirming MSHA approval number <span class=\"chinese-note\">\u8981\u6c42\u5236\u9020\u5546\u8ba4\u8bc1\u4fe1\u786e\u8ba4MSHA\u6279\u51c6\u7f16\u53f7<\/span><\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">Physical Inspection <span class=\"chinese-note\">\u7269\u7406\u68c0\u67e5<\/span><\/td>\n                        <td>Verify MSHA marking legibility on actual cable jacket before acceptance <span class=\"chinese-note\">\u9a8c\u6536\u524d\u9a8c\u8bc1\u5b9e\u9645\u7535\u7f06\u62a4\u5957\u4e0aMSHA\u6807\u8bc6\u7684\u6e05\u6670\u5ea6<\/span><\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">Approval Verification <span class=\"chinese-note\">\u6279\u51c6\u9a8c\u8bc1<\/span><\/td>\n                        <td>Cross-reference approval number against current MSHA acceptance listings <span class=\"chinese-note\">\u5c06\u6279\u51c6\u7f16\u53f7\u4e0e\u5f53\u524dMSHA\u8ba4\u53ef\u6e05\u5355\u4ea4\u53c9\u6838\u5bf9<\/span><\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">Documentation <span class=\"chinese-note\">\u6587\u6863\u8bb0\u5f55<\/span><\/td>\n                        <td>Maintain procurement records, certifications, and approval documentation <span class=\"chinese-note\">\u7ef4\u62a4\u91c7\u8d2d\u8bb0\u5f55\u3001\u8ba4\u8bc1\u548c\u6279\u51c6\u6587\u4ef6<\/span><\/td>\n                    <\/tr>\n                    <tr>\n                        <td class=\"spec-label\">Installation Records <span class=\"chinese-note\">\u5b89\u88c5\u8bb0\u5f55<\/span><\/td>\n                        <td>Document cable locations, approval numbers, and installation dates <span class=\"chinese-note\">\u8bb0\u5f55\u7535\u7f06\u4f4d\u7f6e\u3001\u6279\u51c6\u7f16\u53f7\u548c\u5b89\u88c5\u65e5\u671f<\/span><\/td>\n                    <\/tr>\n                <\/tbody>\n            <\/table>\n        <\/div>\n\n        <h2>Consequences of Non-Compliance <span class=\"chinese\">\u4e0d\u5408\u89c4\u7684\u540e\u679c<\/span><\/h2>\n\n        <p>Mining operations found using non-MSHA-approved cables in underground environments face substantial regulatory consequences extending well beyond simple administrative citations. MSHA inspectors possess authority to issue citations for violations of cable approval requirements under 30 CFR Part 75 for coal mines or Part 57 for metal and nonmetal mines. These citations typically carry significant civil monetary penalties calculated based on violation severity, operator history, demonstrated negligence, and the number of miners potentially affected by the safety hazard.<\/p>\n\n        <p>Beyond immediate financial penalties, serious or flagrant violations may result in closure orders requiring immediate cessation of mining operations in affected areas until the hazardous conditions are abated through cable replacement with properly approved units. Repeat violations or patterns of disregard for cable approval requirements can trigger enhanced enforcement actions including pattern of violations determinations, which subject operators to mandatory additional inspections and accelerated penalty assessments for any subsequent violations.<\/p>\n\n        <p>From a liability perspective, deployment of non-approved cables creates substantial exposure in the unfortunate event of underground fires. Should a fire occur and investigation reveals that non-MSHA-approved cables contributed to fire initiation, propagation, or severity, operators may face civil litigation from injured workers, criminal prosecution for willful violations resulting in death or serious injury, and potential exclusion from federal coal leasing programs or loss of mining permits. Insurance coverage may also be compromised if insurers determine that non-compliant cable use constituted a material misrepresentation of safety practices or a deviation from industry standard of care.<\/p>\n\n        <div class=\"citation\">\n            <h3>Authoritative Sources &#038; References<\/h3>\n            <p><strong>[1]<\/strong> Mine Safety and Health Administration. &#8220;Flame-Resistant Cables Accepted by MSHA Under Code of Federal Regulations Title 30, Part 18, Section 18.64 and Part 7, Subpart K, Section 7.407.&#8221; MSHA Approval and Certification Center, September 2025. <a href=\"https:\/\/arlweb.msha.gov\/TECHSUPP\/ACC\/lists\/07cables.pdf\" rel=\"nofollow noopener\" target=\"_blank\">MSHA Official Cable Acceptance Listing<\/a><\/p>\n            \n            <p><strong>[2]<\/strong> U.S. Code of Federal Regulations. &#8220;30 CFR Part 7, Subpart K &#8211; Testing, Evaluation, and Approval of Mining Products.&#8221; Electronic Code of Federal Regulations. <a href=\"https:\/\/www.ecfr.gov\/current\/title-30\/chapter-I\/subchapter-B\/part-7\/subpart-K\" rel=\"nofollow noopener\" target=\"_blank\">30 CFR Part 7 Full Text<\/a><\/p>\n            \n            <p><strong>[3]<\/strong> U.S. Code of Federal Regulations. &#8220;30 CFR Part 57 &#8211; Safety and Health Standards &#8211; Underground Metal and Nonmetal Mines, Section 57.12002.&#8221; <a href=\"https:\/\/www.ecfr.gov\/current\/title-30\/chapter-I\/subchapter-K\/part-57\" rel=\"nofollow noopener\" target=\"_blank\">30 CFR Part 57 Underground Mining Standards<\/a><\/p>\n            \n            <p><strong>[4]<\/strong> Mine Safety and Health Administration. &#8220;Application Procedure for Approval of Electric Cables and Cable Couplers (ASAP 5007).&#8221; MSHA Approval and Certification Center. <a href=\"https:\/\/arlweb.msha.gov\/techsupp\/acc\/application\/asap5007.pdf\" rel=\"nofollow noopener\" target=\"_blank\">MSHA Cable Approval Application Procedures<\/a><\/p>\n            \n            <p><strong>[5]<\/strong> Southwire Company. &#8220;Type W Portable Power Cable Technical Specifications and MSHA Approval Markings.&#8221; Southwire Cable Technical Support. <a href=\"https:\/\/cabletechsupport.southwire.com\/en\/tile\/5\/cable\/4067\/?country=US\" rel=\"nofollow noopener\" target=\"_blank\">Type W Cable MSHA Specifications<\/a><\/p>\n            \n            <p><strong>[6]<\/strong> TPC Wire &#038; Cable Corp. &#8220;MSHA Approved Cables &#038; Accessories for Mining Operations.&#8221; TPC Industrial Blog, November 2022. <a href=\"https:\/\/www.tpcwire.com\/blog\/msha-approved-cables-accessories-you-need-for-mining-operations\" rel=\"nofollow noopener\" target=\"_blank\">MSHA Cable Requirements Guide<\/a><\/p>\n            \n            <p><strong>[7]<\/strong> TPC Wire &#038; Cable Corp. &#8220;Avoiding MSHA Citations: Choosing the Right Wire and Cable in Mining.&#8221; TPC Industrial Blog, January 2025. <a href=\"https:\/\/www.tpcwire.com\/blog\/avoiding-msha-citations-choosing-the-right-wire-and-cable-in-mining\" rel=\"nofollow noopener\" target=\"_blank\">MSHA Compliance Best Practices<\/a><\/p>\n            \n            <p><strong>[8]<\/strong> TOT Cables. &#8220;Type W Cable: Complete Guide to Specifications, Applications, and Benefits.&#8221; TOT Cables Technical Library, May 2025. <a href=\"https:\/\/totcables.com\/news\/type-w-cable-complete-guide-to-specifications-applications-and-benefits\/\" rel=\"nofollow noopener\" target=\"_blank\">Type W Cable Comprehensive Guide<\/a><\/p>\n            \n            <p><strong>[9]<\/strong> ICEA Standards. &#8220;ICEA S-75-381\/NEMA WC 58 &#8211; Portable and Power Feeder Cables for Use in Mines and Similar Applications.&#8221; Insulated Cable Engineers Association. <a href=\"https:\/\/www.icea.net\/\" rel=\"nofollow noopener\" target=\"_blank\">ICEA Mining Cable Standards<\/a><\/p>\n        <\/div>\n\n        <div class=\"contact-section\">\n            <h2>Contact Anhui Feichun Special Cable Co., Ltd. <span class=\"chinese\">\u8054\u7cfb\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/span><\/h2>\n            <p>For inquiries regarding MSHA-approved Type W cables, custom cable specifications designed to meet specific underground mining requirements, technical consultation on cable approval processes, or assistance with MSHA compliance verification, please contact our specialized technical team. Anhui Feichun Special Cable maintains comprehensive expertise in international cable standards and can provide guidance on meeting United States MSHA requirements for mining operations.<\/p>\n            <p class=\"chinese-note\">\u5982\u9700\u4e86\u89e3MSHA\u8ba4\u53ef\u7684W\u578b\u7535\u7f06\u3001\u7b26\u5408\u7279\u5b9a\u5730\u4e0b\u91c7\u77ff\u8981\u6c42\u7684\u5b9a\u5236\u7535\u7f06\u89c4\u683c\u3001\u7535\u7f06\u6279\u51c6\u6d41\u7a0b\u7684\u6280\u672f\u54a8\u8be2\u6216MSHA\u5408\u89c4\u9a8c\u8bc1\u534f\u52a9,\u8bf7\u8054\u7cfb\u6211\u4eec\u7684\u4e13\u4e1a\u6280\u672f\u56e2\u961f\u3002\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u5728\u56fd\u9645\u7535\u7f06\u6807\u51c6\u65b9\u9762\u62e5\u6709\u5168\u9762\u7684\u4e13\u4e1a\u77e5\u8bc6,\u53ef\u4ee5\u4e3a\u6ee1\u8db3\u7f8e\u56fd\u91c7\u77ff\u4f5c\u4e1a\u7684MSHA\u8981\u6c42\u63d0\u4f9b\u6307\u5bfc\u3002<\/p>\n            \n            <div class=\"contact-grid\">\n                <div class=\"contact-item\">\n                    <div class=\"contact-label\">WhatsApp <span class=\"chinese-note\">\u5fae\u4fe1\/WhatsApp<\/span><\/div>\n                    <div class=\"contact-value\"><a href=\"https:\/\/wa.me\/8613855123218\" rel=\"nofollow noopener\" target=\"_blank\">+86 138 5512 3218<\/a><\/div>\n                <\/div>\n                \n                <div class=\"contact-item\">\n                    <div class=\"contact-label\">Technical Email <span class=\"chinese-note\">\u6280\u672f\u90ae\u7bb1<\/span><\/div>\n                    <div class=\"contact-value\"><a href=\"mailto:tech@feichuncables.com\" rel=\"nofollow\">tech@feichuncables.com<\/a><\/div>\n                <\/div>\n                \n                <div class=\"contact-item\">\n                    <div class=\"contact-label\">Sales Contact <span class=\"chinese-note\">\u9500\u552e\u8054\u7cfb<\/span><\/div>\n                    <div class=\"contact-value\"><a href=\"mailto:zihao.yang@feichuncables.com\" rel=\"nofollow\">zihao.yang@feichuncables.com<\/a><\/div>\n                <\/div>\n                \n                <div class=\"contact-item\">\n                    <div class=\"contact-label\">Engineering Support <span class=\"chinese-note\">\u5de5\u7a0b\u652f\u6301<\/span><\/div>\n                    <div class=\"contact-value\"><a href=\"mailto:ziyu.huang@feichuncables.com\" rel=\"nofollow\">ziyu.huang@feichuncables.com<\/a><\/div>\n                <\/div>\n            <\/div>\n        <\/div>\n    <\/main>\n\n    <footer>\n        <div class=\"container\">\n            <p>&copy; 2026 Anhui Feichun Special Cable Co., Ltd. (\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8) | All technical information provided for educational purposes. Consult with MSHA and qualified professionals for specific compliance determinations.<\/p>\n            <p style=\"margin-top: 10px; font-size: 0.9em;\">Building A Private Science and Technology Park, Hefei Economic and Technological Development Zone, Anhui Province, China<\/p>\n        <\/div>\n    <\/footer>\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"Understanding Mine Safety and Health Administration approval markings on Type W portable power cables is essential for compliance with United States underground mining regulations. The P-136-MSHA designation represents a specific manufacturer approval code combined with MSHA certification, indicating that a cable has successfully passed rigorous flame resistance testing and meets federal safety standards for underground mining applications. This comprehensive guide examines MSHA approval requirements, explains the significance of manufacturer-specific approval numbers, and clarifies when Type W cables require MSHA certification for legal underground deployment.\n\u4e86\u89e3W\u578b\u4fbf\u643a\u5f0f\u7535\u529b\u7535\u7f06\u4e0a\u7684\u77ff\u5c71\u5b89\u5168\u4e0e\u5065\u5eb7\u7ba1\u7406\u5c40(MSHA)\u8ba4\u8bc1\u6807\u8bc6\u5bf9\u4e8e\u7b26\u5408\u7f8e\u56fd\u5730\u4e0b\u91c7\u77ff\u6cd5\u89c4\u81f3\u5173\u91cd\u8981\u3002P-136-MSHA\u6807\u8bc6\u4ee3\u8868\u7279\u5b9a\u5236\u9020\u5546\u6279\u51c6\u4ee3\u7801\u4e0eMSHA\u8ba4\u8bc1\u7684\u7ec4\u5408,\u8868\u660e\u7535\u7f06\u5df2\u6210\u529f\u901a\u8fc7\u4e25\u683c\u7684\u963b\u71c3\u6d4b\u8bd5\u5e76\u7b26\u5408\u5730\u4e0b\u91c7\u77ff\u5e94\u7528\u7684\u8054\u90a6\u5b89\u5168\u6807\u51c6\u3002\u672c\u6307\u5357\u8be6\u7ec6\u4ecb\u7ecd\u4e86MSHA\u6279\u51c6\u8981\u6c42,\u89e3\u91ca\u4e86\u5236\u9020\u5546\u7279\u5b9a\u6279\u51c6\u7f16\u53f7\u7684\u610f\u4e49,\u5e76\u9610\u660e\u4e86W\u578b\u7535\u7f06\u4f55\u65f6\u9700\u8981MSHA\u8ba4\u8bc1\u624d\u80fd\u5408\u6cd5\u5730\u4e0b\u90e8\u7f72\u3002","protected":false},"author":1,"featured_media":5304,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[66,56],"tags":[36139,36127,36131,36133,36125,5140,36136,9597,7193,4996,36113,3726,36118,1976,1146,36117,36134,2029,1978,4308,36128,8702,1903,36129,36124,8811,36135,36112,9446,26830,36126,8217,5212,35723,1400,36116,36132,35702,36115,1912,36114,34045,36119,36130,3951,36120,36123,1091,36122,1789,36121,8215,36137,36138],"class_list":["post-5303","post","type-post","status-publish","format-standard","has-post-thumbnail","category-common-problems-encountered-in-cable-applications","category-reeling-cable","tag-anquan-biaozhun-safety-standards","tag-battery-leads","tag-cable-approval-documentation","tag-cable-manufacturer-code","tag-combustion-resistance-cable","tag-construction-power-cable","tag-dixia-caikuang-dianlan-underground-mining-cable","tag-fire-resistant-power-cable","tag-flame-propagation-test","tag-flame-resistant-cable","tag-flame-resistant-cable-msha","tag-flame-retardant-mining-cable-2","tag-flexible-type-w-cable","tag-gassy-mine-cable","tag-generator-cable","tag-heavy-duty-type-w-cable","tag-manufacturer-certification-letter","tag-mining-cable-supplier","tag-mining-pump-cable","tag-mobile-mining-equipment","tag-motor-leads","tag-msha-approval","tag-msha-approved-cable","tag-msha-approved-manufacturer","tag-msha-fire-safety","tag-msha-flame-test","tag-msha-renzheng-msha-certification","tag-p-136-msha-marking","tag-permissible-mining-equipment","tag-portable-lighting-cable","tag-portable-power-distribution","tag-self-extinguishing-cable-2","tag-temporary-power-cable","tag-type-w-2000v-cable","tag-type-w-cable","tag-type-w-cable-applications","tag-type-w-cable-procurement","tag-type-w-cable-specifications","tag-type-w-industrial-cable","tag-type-w-mining-cable","tag-type-w-msha-certification","tag-type-w-portable-power-cable","tag-type-w-power-cable","tag-underground-cable-specification","tag-underground-coal-mine-cable","tag-underground-metal-mine-cable","tag-underground-mine-electrical","tag-underground-mining-cable","tag-underground-mining-safety","tag-underground-power-cable","tag-underground-trailing-cable","tag-vertical-flame-test","tag-w-xing-dianlan-type-w-cable","tag-zuran-dianlan-flame-resistant-cable","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/5303","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=5303"}],"version-history":[{"count":2,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/5303\/revisions"}],"predecessor-version":[{"id":5306,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/5303\/revisions\/5306"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/5304"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=5303"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=5303"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=5303"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}